Engine parameters
The Toyota Tundra has 277 engine parameters.
● Confirmed◆ In testing○ Supported× Not supported
A/F heater duty bank 1 sensor 1 TUNDRA_F_HEATER_DUTY_B1S1
- Request
21 3A - Service 21
PID 3A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
(val × 25 ÷ 4096)- Range
- 0 to 399.9 %
- Unit
- %
In testing for 1999 to 2022, 2026. Not supported for 2023 to 2025.
A/F ratio learn value high, bank 1 TUNDRA_AF_LEARN_HIGH_PORT_B1Confirmed
- Request
22 10 A2 - Service 22
DID 10A2 - Module
700 → 708 - Every
3600 s - Testing for 1999 to 2022, 2026
Example reply from a 2025 Toyota Tundra.
Bits 32 to 39 of the reply, 8 bits.
0x8E = 142 → (142 × 100 ÷ 255 − 50) = 5.686275 %
- Formula
(val × 100 ÷ 255 − 50)- Range
- -50 to 50 %
- Unit
- %
Confirmed for 2023 to 2025. In testing for 1999, 2001 to 2004, 2009, 2012 to 2013, 2016, 2022, 2026. Not supported for 2000, 2005 to 2008, 2010 to 2011, 2014 to 2015, 2017 to 2021.
A/F ratio learn value idle, bank 1 TUNDRA_AF_LEARN_IDLE_PORT_B1Confirmed
- Request
22 10 A2 - Service 22
DID 10A2 - Module
700 → 708 - Every
3600 s - Testing for 1999 to 2022, 2026
Example reply from a 2025 Toyota Tundra.
Bits 0 to 7 of the reply, 8 bits.
0x74 = 116 → (116 × 100 ÷ 255 − 50) = -4.509804 %
- Formula
(val × 100 ÷ 255 − 50)- Range
- -50 to 50 %
- Unit
- %
Confirmed for 2023 to 2025. In testing for 1999, 2001 to 2004, 2009, 2012 to 2013, 2016, 2022, 2026. Not supported for 2000, 2005 to 2008, 2010 to 2011, 2014 to 2015, 2017 to 2021.
A/F ratio learn value low, bank 1 TUNDRA_AF_LEARN_LOW_PORT_B1Confirmed
- Request
22 10 A2 - Service 22
DID 10A2 - Module
700 → 708 - Every
3600 s - Testing for 1999 to 2022, 2026
Example reply from a 2025 Toyota Tundra.
Bits 8 to 15 of the reply, 8 bits.
0x73 = 115 → (115 × 100 ÷ 255 − 50) = -4.901961 %
- Formula
(val × 100 ÷ 255 − 50)- Range
- -50 to 50 %
- Unit
- %
Confirmed for 2023 to 2025. In testing for 1999, 2001 to 2004, 2009, 2012 to 2013, 2016, 2022, 2026. Not supported for 2000, 2005 to 2008, 2010 to 2011, 2014 to 2015, 2017 to 2021.
A/F ratio learn value mid.1, bank 1 TUNDRA_AF_LEARN_MID1_PORT_B1Confirmed
- Request
22 10 A2 - Service 22
DID 10A2 - Module
700 → 708 - Every
3600 s - Testing for 1999 to 2022, 2026
Example reply from a 2025 Toyota Tundra.
Bits 16 to 23 of the reply, 8 bits.
0x96 = 150 → (150 × 100 ÷ 255 − 50) = 8.823529 %
- Formula
(val × 100 ÷ 255 − 50)- Range
- -50 to 50 %
- Unit
- %
Confirmed for 2023 to 2025. In testing for 1999, 2001 to 2004, 2009, 2012 to 2013, 2016, 2022, 2026. Not supported for 2000, 2005 to 2008, 2010 to 2011, 2014 to 2015, 2017 to 2021.
A/F ratio learn value mid.2, bank 1 TUNDRA_AF_LEARN_MID2_PORT_B1Confirmed
- Request
22 10 A2 - Service 22
DID 10A2 - Module
700 → 708 - Every
3600 s - Testing for 1999 to 2022, 2026
Example reply from a 2025 Toyota Tundra.
Bits 24 to 31 of the reply, 8 bits.
0x97 = 151 → (151 × 100 ÷ 255 − 50) = 9.215686 %
- Formula
(val × 100 ÷ 255 − 50)- Range
- -50 to 50 %
- Unit
- %
Confirmed for 2023 to 2025. In testing for 1999, 2001 to 2004, 2009, 2012 to 2013, 2016, 2022, 2026. Not supported for 2000, 2005 to 2008, 2010 to 2011, 2014 to 2015, 2017 to 2021.
A/F ratio learned high, bank 1 TUNDRA_A_F_RATIO_LEARNED_HIGH_BANK_1Confirmed
- Request
22 10 2A - Service 22
DID 102A - Module
700 → 708 - Every
3600 s - Testing for 1999 to 2021, 2026
Example reply from a 2025 Toyota Tundra.
Bits 32 to 39 of the reply, 8 bits.
0x88 = 136 → (136 × 100 ÷ 255 − 50) = 3.333333 %
- Formula
(val × 100 ÷ 255 − 50)- Range
- -50 to 50 %
- Unit
- %
Confirmed for 2022 to 2025. In testing for 1999, 2001 to 2004, 2009, 2013, 2016, 2026. Not supported for 2000, 2005 to 2008, 2010 to 2012, 2014 to 2015, 2017 to 2021.
A/F ratio learned idle, bank 1 TUNDRA_A_F_RATIO_LEARNED_IDLE_BANK_1Confirmed
- Request
22 10 2A - Service 22
DID 102A - Module
700 → 708 - Every
3600 s - Testing for 1999 to 2021, 2026
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255 − 50)- Range
- -50 to 50 %
- Unit
- %
Confirmed for 2022 to 2025. In testing for 1999, 2001 to 2004, 2009, 2013, 2016, 2026. Not supported for 2000, 2005 to 2008, 2010 to 2012, 2014 to 2015, 2017 to 2021.
A/F ratio learned low, bank 1 TUNDRA_A_F_RATIO_LEARNED_LOW_BANK_1Confirmed
- Request
22 10 2A - Service 22
DID 102A - Module
700 → 708 - Every
3600 s - Testing for 1999 to 2021, 2026
Bits 8 to 15 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255 − 50)- Range
- -50 to 50 %
- Unit
- %
Confirmed for 2022 to 2025. In testing for 1999, 2001 to 2004, 2009, 2013, 2016, 2026. Not supported for 2000, 2005 to 2008, 2010 to 2012, 2014 to 2015, 2017 to 2021.
A/F ratio learned mid 1, bank 1 TUNDRA_A_F_RATIO_LEARNED_MID_1_BANK_1Confirmed
- Request
22 10 2A - Service 22
DID 102A - Module
700 → 708 - Every
3600 s - Testing for 1999 to 2021, 2026
Bits 16 to 23 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255 − 50)- Range
- -50 to 50 %
- Unit
- %
Confirmed for 2022 to 2025. In testing for 1999, 2001 to 2004, 2009, 2013, 2016, 2026. Not supported for 2000, 2005 to 2008, 2010 to 2012, 2014 to 2015, 2017 to 2021.
A/F ratio learned mid 2, bank 1 TUNDRA_A_F_RATIO_LEARNED_MID_2_BANK_1Confirmed
- Request
22 10 2A - Service 22
DID 102A - Module
700 → 708 - Every
3600 s - Testing for 1999 to 2021, 2026
Example reply from a 2025 Toyota Tundra.
Bits 24 to 31 of the reply, 8 bits.
0x8A = 138 → (138 × 100 ÷ 255 − 50) = 4.117647 %
- Formula
(val × 100 ÷ 255 − 50)- Range
- -50 to 50 %
- Unit
- %
Confirmed for 2022 to 2025. In testing for 1999, 2001 to 2004, 2009, 2013, 2016, 2026. Not supported for 2000, 2005 to 2008, 2010 to 2012, 2014 to 2015, 2017 to 2021.
A/F test results 1, incomplete TUNDRA_F_TEST_RESULTS_1
- Request
21 E3 - Service 21
PID E3 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 15 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1999 to 2022, 2026. Not supported for 2023 to 2025.
Accessory relay on TUNDRA_ACC_RELAY_ON
- Request
21 39 - Service 21
PID 39 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bit 46 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1999 to 2022, 2026. Not supported for 2023 to 2025.
Accumulator open TUNDRA_ACCUMULATOR_OPEN
- Request
21 BE - Service 21
PID BE - Module
7B0 → 7B8 - Every
1 s - Testing for 1999 to 2017, 2022 to 2026
Bit 16 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
In testing for 1999, 2001 to 2004, 2009, 2012 to 2013, 2016, 2022, 2026. Supported for 2018 to 2021. Not supported for 2000, 2005 to 2008, 2010 to 2011, 2014 to 2015, 2017, 2023 to 2025.
Acoustic control induction system vacuum switching valve on TUNDRA_ACIS_VSV_ON
- Request
21 39 - Service 21
PID 39 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bit 3 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1999 to 2022, 2026. Not supported for 2023 to 2025.
Actual engine torque TQ_ACTSAE J1979Confirmed
- Request
01 62 - Service 01
PID 62 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 125)- Range
- -125 to 130 %
- Unit
- %
Confirmed for 2021. Supported for 2024.
Actual engine torque TUNDRA_ACT_ENG_TQ
- Request
21 49 - Service 21
PID 49 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 24 to 39 of the reply, 16 bits.
- Formula
(val − 32768)- Range
- -32768 to 32767 N·m
- Unit
- N·m
In testing for 1999 to 2022, 2026. Not supported for 2023 to 2025.
Actuator power supply on TUNDRA_ACTUATOR_POWER_SUP_ONConfirmed
- Request
21 41 - Service 21
PID 41 - Module
7E0 → 7E8 - Every
3600 s - Testing for 1999 to 2017, 2020 to 2026
Example reply from a 2019 Toyota Tundra.
Bit 146 of the reply.
0b1 = 1 → 1
- Formula
val- Range
- 0 to 1
- Unit
- Number
Confirmed for 2018 to 2019. In testing for 1999 to 2017, 2020 to 2022, 2026. Not supported for 2023 to 2025.
Air conditioning compressor TUNDRA_AC_COMP
- Request
21 E6 - Service 21
PID E6 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 2 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 1999 to 2022, 2026. Not supported for 2023 to 2025.
Air conditioning power consumption TUNDRA_AC_POWER_CONSConfirmed
- Request
22 10 6E - Service 22
DID 106E - Module
7D2 → 7DA - Every
1 s - Testing for 1999 to 2022, 2024, 2026
Example reply from a 2025 Toyota Tundra.
Bits 0 to 7 of the reply, 8 bits.
0x0B = 11 → (11 ÷ 20) = 0.55 kW
- Formula
(val ÷ 20)- Range
- 0 to 12.75 kW
- Unit
- kW
Confirmed for 2023, 2025. In testing for 2022, 2026. Not supported for 2024.
Air flow rate from mass air flow sensor MAFSAE J1979Confirmed
Pelican can show this parameter as the mass air flow.
- Request
01 10 - Service 01
PID 10 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655.35 g/s
- Unit
- g/s
Confirmed for 2008, 2014 to 2015, 2019. Supported for 2005 to 2007, 2010 to 2013, 2016 to 2018, 2020 to 2021.
Air mix servo target pulse, driver TUNDRA_AIR_MIX_SERVO_TARG_D
- Request
21 41 - Service 21
PID 41 - Module
7C4 → 7CC - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1999 to 2022, 2026. Not supported for 2023 to 2025.
Air mix servo, actual pulse, d TUNDRA_AIR_MIX_SERVO_ACT_D
- Request
21 41 - Service 21
PID 41 - Module
7C4 → 7CC - Every
1 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1999 to 2022, 2026. Not supported for 2023 to 2025.
Air-fuel equivalence ratio, bank 1 sensor 1 TUNDRA_AF_LAMBDA_B1S1Confirmed
Pelican can show this parameter as the O2 lambda.
- Request
21 04 - Service 21
PID 04 - Module
7E0 → 7E8 - Every
1 s - Testing for 1999 to 2004, 2009, 2012 to 2013, 2016, 2022 to 2026
Example reply from a 2021 Toyota Tundra.
Bits 16 to 31 of the reply, 16 bits.
0x7FF2 = 32754 → (32754 × 1.99 ÷ 65535) = 0.99459
- Formula
(val × 1.99 ÷ 65535)- Range
- 0 to 1.99
- Unit
- Number
Confirmed for 2010 to 2011, 2014 to 2015, 2017 to 2021. In testing for 1999, 2001 to 2004, 2009, 2012 to 2013, 2016, 2022, 2026. Supported for 2005 to 2008. Not supported for 2000, 2023 to 2025.
Air-fuel sensor current, bank 1 sensor 1 TUNDRA_AFS_I_B1S1Confirmed
- Request
21 04 - Service 21
PID 04 - Module
7E0 → 7E8 - Every
1 s - Testing for 1999 to 2004, 2009, 2012 to 2013, 2016, 2022 to 2026
Bits 96 to 111 of the reply, 16 bits.
- Formula
(val ÷ 256 − 128)- Range
- -128 to 127.99 mA
- Unit
- mA
Confirmed for 2010 to 2011, 2014 to 2015, 2017 to 2021. In testing for 1999, 2001 to 2004, 2009, 2012 to 2013, 2016, 2022, 2026. Supported for 2005 to 2008. Not supported for 2000, 2023 to 2025.
Air-fuel sensor voltage, bank 1 sensor 1 TUNDRA_AFS_V_B1S1Confirmed
- Request
21 04 - Service 21
PID 04 - Module
7E0 → 7E8 - Every
1 s - Testing for 1999 to 2004, 2009, 2012 to 2013, 2016, 2022 to 2026
Example reply from a 2021 Toyota Tundra.
Bits 32 to 47 of the reply, 16 bits.
0x68A9 = 26793 → (26793 × 7.99 ÷ 65535) = 3.266591 V
- Formula
(val × 7.99 ÷ 65535)- Range
- 0 to 7.99 V
- Unit
- V
Confirmed for 2010 to 2011, 2014 to 2015, 2017 to 2021. In testing for 1999, 2001 to 2004, 2009, 2012 to 2013, 2016, 2022, 2026. Supported for 2005 to 2008. Not supported for 2000, 2023 to 2025.
Alt voltage - active test TUNDRA_ALT_VOL_ACTIVE_TEST
- Request
21 42 - Service 21
PID 42 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 48 to 63 of the reply, 16 bits.
- Formula
(val × 5 ÷ 4096)- Range
- 0 to 79.998 V
- Unit
- V
In testing for 1999 to 2022, 2026. Not supported for 2023 to 2025.
Alt voltage - non active test TUNDRA_ALT_VOL_NON_ACTIVE
- Request
21 42 - Service 21
PID 42 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
(val × 5 ÷ 4096)- Range
- 0 to 79.998 V
- Unit
- V
In testing for 1999 to 2022, 2026. Not supported for 2023 to 2025.
Alternator output duty TUNDRA_ALTERNATOR_OUTPUT
- Request
21 42 - Service 21
PID 42 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
(val × 25 ÷ 4096)- Range
- 0 to 399.9 %
- Unit
- %
In testing for 1999 to 2022, 2026. Not supported for 2023 to 2025.
Alternator output duty cycle TUNDRA_ALT_DUTY_CYCLEConfirmed
- Request
22 15 FA - Service 22
DID 15FA - Module
700 → 708 - Every
1 s - Testing for 1999 to 2022, 2026
Example reply from a 2025 Toyota Tundra.
Bits 0 to 15 of the reply, 16 bits.
0x0000 = 0 → (0 ÷ 164) = 0 %
- Formula
(val ÷ 164)- Range
- 0 to 399 %
- Unit
- %
Confirmed for 2023 to 2025. In testing for 1999, 2001 to 2004, 2009, 2012 to 2013, 2016, 2022, 2026. Not supported for 2000, 2005 to 2008, 2010 to 2011, 2014 to 2015, 2017 to 2021.
Ambient temperature TUNDRA_AAT_7D2Confirmed
- Request
22 1F 46 - Service 22
DID 1F46 - Module
7D2 → 7DA - Every
1 s - Testing for 2026
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2022 to 2025. In testing for 2026. Not supported for 2000, 2005 to 2008, 2010 to 2012, 2014 to 2015, 2017 to 2021.
Automatic transmission fluid thermal degradation estimate TUNDRA_ATF_THERMAL_DEGRAD_ESTConfirmed
- Request
22 16 2B - Service 22
DID 162B - Module
701 → 709 - Every
1 s - Testing for 1999 to 2022, 2026
Example reply from a 2025 Toyota Tundra.
Bits 0 to 15 of the reply, 16 bits.
0x0022 = 34 → 34
- Formula
val- Range
- 0 to 65535
- Unit
- Number
Confirmed for 2023 to 2025. In testing for 1999, 2001 to 2004, 2009, 2012 to 2013, 2016, 2022, 2026. Not supported for 2000, 2005 to 2008, 2010 to 2011, 2014 to 2015, 2017 to 2021.
Barometric pressure TUNDRA_BAROConfirmed
- Request
21 01 - Service 21
PID 01 - Module
7E0 → 7E8 - Every
1 s - Testing for 1999 to 2004, 2009, 2012 to 2013, 2022 to 2026
Example reply from a 2021 Toyota Tundra.
Bits 56 to 63 of the reply, 8 bits.
0x62 = 98 → 98 kPa
- Formula
val- Range
- 0 to 255 kPa
- Unit
- kPa
Confirmed for 2010 to 2011, 2015, 2018 to 2021. In testing for 1999, 2001 to 2004, 2009, 2012 to 2013, 2022, 2026. Supported for 2005 to 2008. Not supported for 2000, 2023 to 2025.
Barometric pressure TUNDRA_BARO_V2Confirmed
- Request
21 01 - Service 21
PID 01 - Module
7E0 → 7E8 - Every
1 s - Testing for 2016
Example reply from a 2017 Toyota Tundra.
Bits 48 to 55 of the reply, 8 bits.
0x27 = 39 → 39 kPa
- Formula
val- Range
- 0 to 255 kPa
- Unit
- kPa
Confirmed for 2014, 2017. In testing for 2016.
Calculated engine load LOAD_PCTSAE J1979Confirmed
Represents the amount of work the engine is doing. Expected to reach 100% at wide open throttle/wide open pedal at any altitude, temperature or rpm for both naturally aspirated and boosted engines. If engine load is limited for powertrain protection e.g. engine/turbocharger protection, this value may not reach 100%. For hybrid vehicles, indicates the torque produced only by the internal combustion engine, not the torque being delivered by the entire powertrain. For electric vehicles, the meaning of this parameter is undefined.
Pelican can show this parameter as the engine load.
- Request
01 04 - Service 01
PID 04 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2005 to 2008, 2014 to 2015, 2019 to 2021, 2023 to 2024. Supported for 2010 to 2013, 2016 to 2018, 2022, 2025.
Calculated load TUNDRA_LOADConfirmed
Pelican can show this parameter as the engine load.
- Request
21 01 - Service 21
PID 01 - Module
7E0 → 7E8 - Every
1 s - Testing for 1999 to 2004, 2009, 2012 to 2013, 2022 to 2026
Example reply from a 2021 Toyota Tundra.
Bits 0 to 7 of the reply, 8 bits.
0x54 = 84 → (84 × 100 ÷ 255) = 32.941176 %
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2005 to 2008, 2010 to 2011, 2015, 2018 to 2021. In testing for 1999, 2001 to 2004, 2009, 2012 to 2013, 2022, 2026. Not supported for 2000, 2023 to 2025.
Calculated load TUNDRA_LOAD_V2Confirmed
Pelican can show this parameter as the engine load.
- Request
21 01 - Service 21
PID 01 - Module
7E0 → 7E8 - Every
1 s - Testing for 2016
Example reply from a 2017 Toyota Tundra.
Bits 0 to 7 of the reply, 8 bits.
0x30 = 48 → (48 × 100 ÷ 255) = 18.823529 %
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2014, 2017. In testing for 2016.
Catalyst temperature bank 2 sensor 1 TUNDRA_CAT_T_BANK_2_SENS_1Confirmed
- Request
22 1F 3D - Service 22
DID 1F3D - Module
700 → 708 - Every
5 s - Testing for 1999 to 2022, 2026
Example reply from a 2025 Toyota Tundra.
Bits 0 to 15 of the reply, 16 bits.
0x0389 = 905 → (905 × 9 ÷ 50 − 40) = 122.9 °F
- Formula
(val × 9 ÷ 50 − 40)- Range
- -40 to 11756.3 °F
- Unit
- °F
Confirmed for 2023 to 2025. In testing for 1999 to 2007, 2009 to 2014, 2016 to 2017, 2020 to 2022, 2026. Not supported for 2008, 2015, 2018 to 2019.
Catalyst temperature bank 2 sensor 2 TUNDRA_CAT_T_BANK_2_SENS_2Confirmed
- Request
22 1F 3F - Service 22
DID 1F3F - Module
700 → 708 - Every
5 s - Testing for 1999 to 2022, 2026
Example reply from a 2025 Toyota Tundra.
Bits 0 to 15 of the reply, 16 bits.
0x02F3 = 755 → (755 × 9 ÷ 50 − 40) = 95.9 °F
- Formula
(val × 9 ÷ 50 − 40)- Range
- -40 to 11756.3 °F
- Unit
- °F
Confirmed for 2023 to 2025. In testing for 1999 to 2007, 2009 to 2014, 2016 to 2017, 2020 to 2022, 2026. Not supported for 2008, 2015, 2018 to 2019.
Catalyst temperature, bank 1 sensor 1 TUNDRA_CAT_T_B1S1Confirmed
- Request
21 05 - Service 21
PID 05 - Module
7E0 → 7E8 - Every
5 s - Testing for 1999 to 2004, 2009, 2012 to 2013, 2016, 2022 to 2026
Example reply from a 2021 Toyota Tundra.
Bits 16 to 31 of the reply, 16 bits.
0x110A = 4362 → (4362 ÷ 10 − 40) = 396.2 °C
- Formula
(val ÷ 10 − 40)- Range
- -40 to 6513.5 °C
- Unit
- °C
Confirmed for 2010 to 2011, 2014 to 2015, 2017 to 2021. In testing for 1999, 2001 to 2004, 2009, 2012 to 2013, 2016, 2022, 2026. Supported for 2005 to 2008. Not supported for 2000, 2023 to 2025.
Catalyst temperature, bank 1 sensor 2 TUNDRA_CAT_T_B1S2Confirmed
- Request
21 05 - Service 21
PID 05 - Module
7E0 → 7E8 - Every
5 s - Testing for 1999 to 2004, 2009, 2012 to 2013, 2016, 2022 to 2026
Example reply from a 2021 Toyota Tundra.
Bits 48 to 63 of the reply, 16 bits.
0x0DD0 = 3536 → (3536 ÷ 10 − 40) = 313.6 °C
- Formula
(val ÷ 10 − 40)- Range
- -40 to 6513.5 °C
- Unit
- °C
Confirmed for 2010 to 2011, 2014 to 2015, 2017 to 2021. In testing for 1999, 2001 to 2004, 2009, 2012 to 2013, 2016, 2022, 2026. Supported for 2005 to 2008. Not supported for 2000, 2023 to 2025.
Catalyst temperature, bank 1 sensor 2, variant 2 TUNDRA_CAT_T_B1S2_V2
- Request
21 3E - Service 21
PID 3E - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10 − 40)- Range
- -40 to 6513.5 °C
- Unit
- °C
In testing for 1999 to 2022, 2026. Not supported for 2023 to 2025.
Check mode on TUNDRA_CHECK_MODE_ON
- Request
21 E3 - Service 21
PID E3 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 0 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1999 to 2022, 2026. Not supported for 2023 to 2025.
Closed throttle position switch on TUNDRA_CLOSED_THROTTLE_POS_ON
- Request
21 37 - Service 21
PID 37 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bit 125 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1999 to 2022, 2026. Not supported for 2023 to 2025.
Codes, include history TUNDRA_CODES_INCLUDE
- Request
21 E1 - Service 21
PID E1 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1999 to 2022, 2026. Not supported for 2023 to 2025.
Commanded equivalence ratio EQ_RATSAE J1979Confirmed
Fuel systems that utilize conventional oxygen sensor display the inverse of the commanded open loop equivalence ratio (also known as lambda) while the fuel control system is in open loop. Will indicate 1.000 while in closed-loop fuel.
Pelican can show this parameter as the commanded lambda.
- Request
01 44 - Service 01
PID 44 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 2 ÷ 65535)- Range
- 0 to 1.99
- Unit
- Number
Confirmed for 2005 to 2008, 2014 to 2015, 2019 to 2021, 2024 to 2025. Supported for 2022 to 2023.
Continuously variable transmission learning complete TUNDRA_CVT_LEARNED
- Request
21 DD - Service 21
PID DD - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 7 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Yes or no
In testing for 1999 to 2022, 2026. Not supported for 2023 to 2025.
Continuously variable transmission oil pressure TUNDRA_CVT_OIL_P
- Request
21 BE - Service 21
PID BE - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 40)- Range
- 0 to 10200 kPa
- Unit
- kPa
In testing for 1999 to 2022, 2026. Not supported for 2023 to 2025.
Coolant temperature TUNDRA_COOL_TConfirmed
- Request
22 1F 05 - Service 22
DID 1F05 - Module
7D2 → 7DA - Every
1 s - Testing for 2026
Example reply from a 2025 Toyota Tundra.
Bits 0 to 7 of the reply, 8 bits.
0x31 = 49 → (49 − 40) = 9 °C
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2022 to 2025. In testing for 2026. Not supported for 2000, 2005 to 2008, 2010 to 2012, 2014 to 2015, 2017 to 2021.
Coolant water route switching valve 1, closed? TUNDRA_COOLANT_VALVE_1_CLOSE
- Request
22 28 2C - Service 22
DID 282C - Module
700 → 708 - Every
1 s - Testing
Bit 15 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
In testing for 1999, 2001 to 2004, 2009, 2012 to 2013, 2016, 2022, 2026. Not supported for 2000, 2005 to 2008, 2010 to 2011, 2014 to 2015, 2017 to 2021, 2023 to 2025.
Coolant water route switching valve 2, closed? TUNDRA_COOLANT_VALVE_2_CLOSE
- Request
22 28 47 - Service 22
DID 2847 - Module
700 → 708 - Every
1 s - Testing
Bit 15 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
In testing for 1999, 2001 to 2004, 2009, 2012 to 2013, 2016, 2022, 2026. Not supported for 2000, 2005 to 2008, 2010 to 2011, 2014 to 2015, 2017 to 2021, 2023 to 2025.
Cooling fan duty ratio TUNDRA_COOLING_FAN_DUTY_RATIOConfirmed
- Request
22 10 46 - Service 22
DID 1046 - Module
700 → 708 - Every
1 s - Testing for 1999 to 2022, 2026
Example reply from a 2025 Toyota Tundra.
Bits 0 to 7 of the reply, 8 bits.
0x00 = 0 → (0 × 127.5 ÷ 255) = 0 %
- Formula
(val × 127.5 ÷ 255)- Range
- 0 to 127.5 %
- Unit
- %
Confirmed for 2023 to 2025. In testing for 1999, 2001 to 2004, 2009, 2012 to 2013, 2016, 2022, 2026. Not supported for 2000, 2005 to 2008, 2010 to 2011, 2014 to 2015, 2017 to 2021.
Cruise control on TUNDRA_CRUISE_CTRL_ON
- Request
21 D3 - Service 21
PID D3 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bit 25 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 1999 to 2022, 2026. Not supported for 2023 to 2025.
Cylinder 1 injection volume TUNDRA_CYL_1_INJ_VOLUME
- Request
22 11 31 - Service 22
DID 1131 - Module
700 → 708 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 19531 ÷ 1000000 − 640)- Range
- -640 to 15
- Unit
- Raw value
In testing for 1999 to 2007, 2009 to 2014, 2016 to 2017, 2020 to 2022, 2026. Not supported for 2008, 2015, 2018 to 2019, 2023 to 2025.
Cylinder 2 injection volume TUNDRA_CYL_2_INJ_VOLUME
- Request
22 11 31 - Service 22
DID 1131 - Module
700 → 708 - Every
1 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val × 19531 ÷ 1000000 − 640)- Range
- -640 to 15
- Unit
- Raw value
In testing for 1999 to 2007, 2009 to 2014, 2016 to 2017, 2020 to 2022, 2026. Not supported for 2008, 2015, 2018 to 2019, 2023 to 2025.
Cylinder 3 injection volume TUNDRA_CYL_3_INJ_VOLUME
- Request
22 11 31 - Service 22
DID 1131 - Module
700 → 708 - Every
1 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
(val × 19531 ÷ 1000000 − 640)- Range
- -640 to 15
- Unit
- Raw value
In testing for 1999 to 2007, 2009 to 2014, 2016 to 2017, 2020 to 2022, 2026. Not supported for 2008, 2015, 2018 to 2019, 2023 to 2025.
Cylinder 4 injection volume TUNDRA_CYL_4_INJ_VOLUME
- Request
22 11 31 - Service 22
DID 1131 - Module
700 → 708 - Every
1 s - Testing
Bits 48 to 63 of the reply, 16 bits.
- Formula
(val × 19531 ÷ 1000000 − 640)- Range
- -640 to 15
- Unit
- Raw value
In testing for 1999 to 2007, 2009 to 2014, 2016 to 2017, 2020 to 2022, 2026. Not supported for 2008, 2015, 2018 to 2019, 2023 to 2025.
Cylinder number TUNDRA_CYLINDER_NUMBER
- Request
21 C1 - Service 21
PID C1 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 104 to 111 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1999 to 2022, 2026. Not supported for 2023 to 2025.
Destination TUNDRA_DESTINATION
- Request
21 C1 - Service 21
PID C1 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 120 to 127 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1999 to 2022, 2026. Not supported for 2023 to 2025.
Dist battery cable disconnect TUNDRA_DIST_BATT_CABLE
- Request
21 37 - Service 21
PID 37 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 96 to 111 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 km
- Unit
- km
In testing for 1999 to 2022, 2026. Not supported for 2023 to 2025.
Electric fan motor on TUNDRA_ELEC_FAN_MOTOR_ON
- Request
21 39 - Service 21
PID 39 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bit 34 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1999 to 2022, 2026. Not supported for 2023 to 2025.
Electric thermostat duty ratio TUNDRA_ELECTRIC_THERMOSTAT_DUTY_RATIO
- Request
22 28 29 - Service 22
DID 2829 - Module
700 → 708 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 %
- Unit
- %
In testing for 1999, 2001 to 2004, 2009, 2012 to 2013, 2016, 2022, 2026. Not supported for 2000, 2005 to 2008, 2010 to 2011, 2014 to 2015, 2017 to 2021, 2023 to 2025.
Electric water pump TUNDRA_ELECTRIC_WATER_PUMP
- Request
22 28 27 - Service 22
DID 2827 - Module
700 → 708 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 40)- Range
- 0 to 10200 rpm
- Unit
- rpm
In testing for 1999, 2001 to 2004, 2009, 2012 to 2013, 2016, 2022, 2026. Not supported for 2000, 2005 to 2008, 2010 to 2011, 2014 to 2015, 2017 to 2021, 2023 to 2025.
Electric water pump RPM TUNDRA_EWP_RPM
- Request
22 10 43 - Service 22
DID 1043 - Module
700 → 708 - Every
250 ms - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
(val × 25)- Range
- 0 to 6375 rpm
- Unit
- rpm
In testing for 1999, 2001 to 2004, 2009, 2013, 2016, 2026. Not supported for 2000, 2005 to 2008, 2010 to 2012, 2014 to 2015, 2017 to 2025.
Electric water pump target speed TUNDRA_EWP_TARGET_VSS
- Request
22 10 43 - Service 22
DID 1043 - Module
700 → 708 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 25)- Range
- 0 to 6375 rpm
- Unit
- rpm
In testing for 1999, 2001 to 2004, 2009, 2013, 2016, 2026. Not supported for 2000, 2005 to 2008, 2010 to 2012, 2014 to 2015, 2017 to 2025.
Engine coolant temperature ECTSAE J1979Confirmed
Your engine temperature must operate within a certain temperature range to operate efficiently and safely. If it runs too hot, then your engine could be permanently damaged. If it runs too cold, then your engine will use more fuel than necessary.
Pelican can show this parameter as the engine coolant temperature.
- Request
01 05 - Service 01
PID 05 - Module
7E0 → 7E8 - Every
500 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2006 to 2008, 2014 to 2015, 2019, 2021. Supported for 2005, 2010 to 2013, 2016 to 2018, 2020, 2022 to 2025.
Engine coolant temperature TUNDRA_ECTConfirmed
Pelican can show this parameter as the engine coolant temperature.
- Request
21 26 - Service 21
PID 26 - Module
7C4 → 7CC - Every
5 s - Testing for 1999 to 2006, 2009, 2012 to 2013, 2016, 2022 to 2026
Example reply from a 2021 Toyota Tundra.
Bits 0 to 7 of the reply, 8 bits.
0x93 = 147 → (147 × 89.25 ÷ 255 + 1.3) = 52.75 °C
- Formula
(val × 89.25 ÷ 255 + 1.3)- Range
- 1.3 to 90.55 °C
- Unit
- °C
Confirmed for 2007 to 2008, 2010 to 2011, 2014 to 2015, 2017 to 2021. In testing for 1999, 2001 to 2004, 2009, 2012 to 2013, 2016, 2022, 2026. Not supported for 2000, 2005 to 2006, 2023 to 2025.
Engine coolant temperature TUNDRA_ECT_7C0Confirmed
Pelican can show this parameter as the engine coolant temperature.
- Request
21 23 - Service 21
PID 23 - Module
7C0 → 7C8 - Every
5 s - Testing for 1999 to 2006, 2009, 2012 to 2013, 2016, 2022 to 2026
Example reply from a 2021 Toyota Tundra.
Bits 0 to 7 of the reply, 8 bits.
0x6E = 110 → (110 ÷ 2) = 55 °C
- Formula
(val ÷ 2)- Range
- 0 to 127.5 °C
- Unit
- °C
Confirmed for 2007 to 2008, 2010 to 2011, 2014 to 2015, 2017 to 2021. In testing for 1999, 2001 to 2004, 2009, 2012 to 2013, 2016, 2022, 2026. Not supported for 2000, 2005 to 2006, 2023 to 2025.
Engine coolant temperature TUNDRA_ECT_7E0Confirmed
Pelican can show this parameter as the engine coolant temperature.
- Request
21 01 - Service 21
PID 01 - Module
7E0 → 7E8 - Every
1 s - Testing for 1999 to 2004, 2009, 2012 to 2013, 2022 to 2026
Example reply from a 2021 Toyota Tundra.
Bits 64 to 71 of the reply, 8 bits.
0x6A = 106 → (106 − 40) = 66 °C
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2010 to 2011, 2015, 2018 to 2021. In testing for 1999, 2001 to 2004, 2009, 2012 to 2013, 2022, 2026. Supported for 2005 to 2008. Not supported for 2000, 2023 to 2025.
Engine coolant temperature TUNDRA_ECT_7E0_V2Confirmed
Pelican can show this parameter as the engine coolant temperature.
- Request
21 01 - Service 21
PID 01 - Module
7E0 → 7E8 - Every
1 s - Testing for 2016
Example reply from a 2017 Toyota Tundra.
Bits 56 to 63 of the reply, 8 bits.
0x82 = 130 → (130 − 40) = 90 °C
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2014, 2017. In testing for 2016.
Engine coolant temperature, at ignition TUNDRA_ECT_IGNConfirmed
- Request
22 10 41 - Service 22
DID 1041 - Module
700 → 708 - Every
5 s - Testing for 1999 to 2022, 2026
Example reply from a 2025 Toyota Tundra.
Bits 0 to 7 of the reply, 8 bits.
0x26 = 38 → (38 × 62.5 ÷ 100 − 40) = -16.25 °C
- Formula
(val × 62.5 ÷ 100 − 40)- Range
- -40 to 119.375 °C
- Unit
- °C
Confirmed for 2023 to 2025. In testing for 1999, 2001 to 2004, 2009, 2012 to 2013, 2016, 2022, 2026. Not supported for 2000, 2005 to 2008, 2010 to 2011, 2014 to 2015, 2017 to 2021.
Engine coolant temperature, initial TUNDRA_ECT_INITConfirmed
- Request
22 10 41 - Service 22
DID 1041 - Module
700 → 708 - Every
5 s - Testing for 1999 to 2022, 2026
Example reply from a 2025 Toyota Tundra.
Bits 8 to 15 of the reply, 8 bits.
0x26 = 38 → (38 × 62.5 ÷ 100 − 40) = -16.25 °C
- Formula
(val × 62.5 ÷ 100 − 40)- Range
- -40 to 119.375 °C
- Unit
- °C
Confirmed for 2023 to 2025. In testing for 1999, 2001 to 2004, 2009, 2012 to 2013, 2016, 2022, 2026. Not supported for 2000, 2005 to 2008, 2010 to 2011, 2014 to 2015, 2017 to 2021.
Engine independent TUNDRA_ENG_INDEPENDENT
- Request
21 49 - Service 21
PID 49 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bit 91 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 1999 to 2022, 2026. Not supported for 2023 to 2025.
Engine independent control TUNDRA_ENG_INDEPENDENT_CTRL
- Request
21 49 - Service 21
PID 49 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bit 88 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 1999 to 2022, 2026. Not supported for 2023 to 2025.
Engine oil pressure TUNDRA_EOPConfirmed
- Request
22 10 74 - Service 22
DID 1074 - Module
700 → 708 - Every
1 s - Testing for 1999 to 2021, 2026
Example reply from a 2025 Toyota Tundra.
Bits 0 to 15 of the reply, 16 bits.
0x0000 = 0 → (0 × 10 ÷ 128) = 0 kPa
- Formula
(val × 10 ÷ 128)- Range
- 0 to 5119.92 kPa
- Unit
- kPa
Confirmed for 2022 to 2025. In testing for 1999, 2001 to 2004, 2009, 2013, 2026. Not supported for 2000, 2005 to 2008, 2010 to 2012, 2014 to 2021.
Engine oil pressure control valve TUNDRA_EOP_CONTROL_VALVE
- Request
22 28 48 - Service 22
DID 2848 - Module
700 → 708 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.0762939)- Range
- 0 to 4999.9207 mA
- Unit
- mA
In testing for 1999, 2001 to 2004, 2009, 2013, 2016, 2026. Not supported for 2000, 2005 to 2008, 2010 to 2012, 2014 to 2015, 2017 to 2025.
Engine oil temperature TUNDRA_EOTConfirmed
Pelican can show this parameter as the engine oil temperature.
- Request
21 51 - Service 21
PID 51 - Module
7E0 → 7E8 - Every
1 s - Testing for 1999 to 2009, 2011, 2013, 2022 to 2026
Example reply from a 2021 Toyota Tundra.
Bits 72 to 79 of the reply, 8 bits.
0x6E = 110 → (110 − 40) = 70 °C
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2010, 2012, 2014 to 2021. In testing for 1999, 2001 to 2004, 2009, 2013, 2026. Not supported for 2000, 2005 to 2008, 2011, 2022 to 2025.
Engine oil temperature TUNDRA_EOT_700Confirmed
Pelican can show this parameter as the engine oil temperature.
- Request
22 10 7B - Service 22
DID 107B - Module
700 → 708 - Every
5 s - Testing for 1999 to 2021, 2026
Example reply from a 2025 Toyota Tundra.
Bits 192 to 199 of the reply, 8 bits.
0x48 = 72 → (72 − 40) = 32 °C
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2022 to 2025. In testing for 1999, 2001 to 2004, 2009, 2013, 2016, 2026. Not supported for 2000, 2005 to 2008, 2010 to 2012, 2014 to 2015, 2017 to 2021.
Engine oil temperature, variation 2 TUNDRA_EOT_V2Confirmed
Pelican can show this parameter as the engine oil temperature.
- Request
22 1F 5C - Service 22
DID 1F5C - Module
700 → 708 - Every
5 s - Testing for 1999 to 2021, 2026
Example reply from a 2025 Toyota Tundra.
Bits 0 to 7 of the reply, 8 bits.
0x2D = 45 → (45 − 40) = 5 °C
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2022 to 2025. In testing for 1999, 2001 to 2004, 2009, 2013, 2016, 2026. Not supported for 2000, 2005 to 2008, 2010 to 2012, 2014 to 2015, 2017 to 2021.
Engine run time TUNDRA_ENGINE_RUN_TIMEConfirmed
- Request
21 01 - Service 21
PID 01 - Module
7E0 → 7E8 - Every
1 s - Testing for 1999 to 2004, 2009, 2012 to 2013, 2022 to 2026
Example reply from a 2021 Toyota Tundra.
Bits 96 to 111 of the reply, 16 bits.
0x03C9 = 969 → 969 s
- Formula
val- Range
- 0 to 65535 s
- Unit
- s
Confirmed for 2010 to 2011, 2015, 2018 to 2021. In testing for 1999, 2001 to 2004, 2009, 2012 to 2013, 2022, 2026. Supported for 2005 to 2008. Not supported for 2000, 2023 to 2025.
Engine run time TUNDRA_ENGINE_RUN_TIME_V2Confirmed
- Request
21 01 - Service 21
PID 01 - Module
7E0 → 7E8 - Every
1 s - Testing for 2016
Example reply from a 2017 Toyota Tundra.
Bits 88 to 103 of the reply, 16 bits.
0x4113 = 16659 → 16,659 s
- Formula
val- Range
- 0 to 65535 s
- Unit
- s
Confirmed for 2014, 2017. In testing for 2016.
Engine run time, up to 255 sec. only TUNDRA_ENG_RUN_TIME_UP_255
- Request
21 49 - Service 21
PID 49 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 s
- Unit
- s
In testing for 1999 to 2022, 2026. Not supported for 2023 to 2025.
Engine stall control FB flow TUNDRA_ENG_STALL_CTRL_FB
- Request
21 52 - Service 21
PID 52 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 48 to 63 of the reply, 16 bits.
- Formula
(val × 5 ÷ 4096 − 40)- Range
- -40 to 39.99
- Unit
- Number
In testing for 1999 to 2022, 2026. Not supported for 2023 to 2025.
Evaporative purge duty TUNDRA_EVAP_PURGE_DUTY_7E0
- Request
21 2E - Service 21
PID 2E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 1999 to 2022, 2026. Not supported for 2023 to 2025.
Evaporative purge flow TUNDRA_EVAP_PURGE_FLOW
- Request
21 37 - Service 21
PID 37 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
(val × 25 ÷ 4096)- Range
- 0 to 399.99 %
- Unit
- %
In testing for 1999 to 2022, 2026. Not supported for 2023 to 2025.
Evaporative purge vacuum switching valve on TUNDRA_EVAP_PURGE_VSV_ON
- Request
21 39 - Service 21
PID 39 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bit 11 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1999 to 2022, 2026. Not supported for 2023 to 2025.
Exhaust gas recirculation step position TUNDRA_EGR_STEP_POSITIONConfirmed
- Request
21 47 - Service 21
PID 47 - Module
7E0 → 7E8 - Every
1 s - Testing for 1999 to 2018, 2020 to 2026
Example reply from a 2019 Toyota Tundra.
Bits 0 to 7 of the reply, 8 bits.
0x00 = 0 → 0
- Formula
val- Range
- 0 to 255
- Unit
- Number
Confirmed for 2019. In testing for 1999 to 2018, 2020 to 2022, 2026. Not supported for 2023 to 2025.
Exhaust gas recirculation temperature TUNDRA_EGR_T
- Request
21 ED - Service 21
PID ED - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 53 ÷ 85)- Range
- 0 to 159 °C
- Unit
- °C
In testing for 1999 to 2022, 2026. Not supported for 2023 to 2025.
Exhaust gas recirculation valve step TUNDRA_EGR_STEP
- Request
21 E7 - Service 21
PID E7 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1999 to 2022, 2026. Not supported for 2023 to 2025.
Exhaust VVT change angle, bank 1 TUNDRA_EXHAUST_VVT_ANGLE_B1Confirmed
- Request
22 10 88 - Service 22
DID 1088 - Module
700 → 708 - Every
1 s - Testing for 1999 to 2022, 2026
Example reply from a 2025 Toyota Tundra.
Bits 0 to 15 of the reply, 16 bits.
0x0000 = 0 → (0 × 639.9 ÷ 65535) = 0 °
- Formula
(val × 639.9 ÷ 65535)- Range
- 0 to 639.9 °
- Unit
- °
Confirmed for 2023 to 2025. In testing for 1999, 2001 to 2004, 2009, 2012 to 2013, 2016, 2022, 2026. Not supported for 2000, 2005 to 2008, 2010 to 2011, 2014 to 2015, 2017 to 2021.
Exhaust VVT hold learn value, bank 1 TUNDRA_EXHAUST_VVT_HOLD_LEARN_B1Confirmed
- Request
22 10 89 - Service 22
DID 1089 - Module
700 → 708 - Every
3600 s - Testing for 1999 to 2022, 2026
Example reply from a 2025 Toyota Tundra.
Bits 0 to 15 of the reply, 16 bits.
0x1E7A = 7802 → (7802 × 399.9 ÷ 65535) = 47.60845 %
- Formula
(val × 399.9 ÷ 65535)- Range
- 0 to 399.9 %
- Unit
- %
Confirmed for 2023 to 2025. In testing for 1999, 2001 to 2004, 2009, 2012 to 2013, 2016, 2022, 2026. Not supported for 2000, 2005 to 2008, 2010 to 2011, 2014 to 2015, 2017 to 2021.
Exhaust VVT oil control valve control duty TUNDRA_EXHAUST_VVT_OCV_CONTROL_DUTYConfirmed
- Request
22 10 62 - Service 22
DID 1062 - Module
700 → 708 - Every
1 s - Testing for 1999 to 2021, 2026
Example reply from a 2025 Toyota Tundra.
Bits 0 to 15 of the reply, 16 bits.
0x0000 = 0 → (0 × 400 ÷ 65535) = 0 %
- Formula
(val × 400 ÷ 65535)- Range
- 0 to 400 %
- Unit
- %
Confirmed for 2022 to 2025. In testing for 1999, 2001 to 2004, 2009, 2013, 2016, 2026. Not supported for 2000, 2005 to 2008, 2010 to 2012, 2014 to 2015, 2017 to 2021.
Exhaust VVT target angle B1 TUNDRA_EXHAUST_VVT_TARGET_ANGLE_B1Confirmed
- Request
22 10 71 - Service 22
DID 1071 - Module
700 → 708 - Every
1 s - Testing for 1999 to 2021, 2026
Example reply from a 2025 Toyota Tundra.
Bits 0 to 15 of the reply, 16 bits.
0x0000 = 0 → (0 × 639.9 ÷ 65535) = 0 °
- Formula
(val × 639.9 ÷ 65535)- Range
- 0 to 639.9 °
- Unit
- °
Confirmed for 2022 to 2025. In testing for 1999, 2001 to 2004, 2009, 2013, 2016, 2026. Not supported for 2000, 2005 to 2008, 2010 to 2012, 2014 to 2015, 2017 to 2021.
Exhaust VVT timing most over-advanced learn value, bank 1 TUNDRA_EXHAUST_VVT_OVER_ADV_LEARN_B1Confirmed
- Request
22 10 8F - Service 22
DID 108F - Module
700 → 708 - Every
3600 s - Testing for 1999 to 2022, 2026
Example reply from a 2025 Toyota Tundra.
Bits 0 to 15 of the reply, 16 bits.
0x2F50 = 12112 → (12112 × 639.99 ÷ 65535) = 118.281207 °
- Formula
(val × 639.99 ÷ 65535)- Range
- 0 to 639.99 °
- Unit
- °
Confirmed for 2023 to 2025. In testing for 1999, 2001 to 2004, 2009, 2012 to 2013, 2016, 2022, 2026. Not supported for 2000, 2005 to 2008, 2010 to 2011, 2014 to 2015, 2017 to 2021.
Front/rear motor torque ratio TUNDRA_FRONT_REAR_MOTOR_TQConfirmed
- Request
22 10 39 - Service 22
DID 1039 - Module
7D2 → 7DA - Every
250 ms - Testing for 1999 to 2022, 2024, 2026
Example reply from a 2025 Toyota Tundra.
Bits 16 to 31 of the reply, 16 bits.
0x0ACE = 2766 → (2766 ÷ 1000 − 32.768) = -30.002
- Formula
(val ÷ 1000 − 32.768)- Range
- -32.76 to 32.76
- Unit
- Number
Confirmed for 2023, 2025. In testing for 2022, 2026. Not supported for 2024.
Fuel cut for engine stop request TUNDRA_F_C_ENG_STOP_REQ
- Request
21 49 - Service 21
PID 49 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bit 92 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 1999 to 2022, 2026. Not supported for 2023 to 2025.
Fuel cut TAU on TUNDRA_FC_TAU_ON
- Request
21 37 - Service 21
PID 37 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bit 127 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1999 to 2022, 2026. Not supported for 2023 to 2025.
Fuel filter temperature TUNDRA_FFT
- Request
22 10 9A - Service 22
DID 109A - Module
700 → 708 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 1999, 2001 to 2004, 2009, 2012 to 2013, 2016, 2022, 2026. Not supported for 2000, 2005 to 2008, 2010 to 2011, 2014 to 2015, 2017 to 2021, 2023 to 2025.
G sensor calibration, complete TUNDRA_G_SENS_CALIBRATION
- Request
21 83 - Service 21
PID 83 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bit 2 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1999 to 2022, 2026. Not supported for 2023 to 2025.
G sensor learning value TUNDRA_G_SENS_LEARNING
- Request
21 83 - Service 21
PID 83 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 8 to 23 of the reply, 16 bits.
- Formula
(val × 5 ÷ 4096)- Range
- 0 to 79.998 V
- Unit
- V
In testing for 1999 to 2022, 2026. Not supported for 2023 to 2025.
Generator inverter temperature TUNDRA_GEN_INVERTER_T
- Request
22 10 A4 - Service 22
DID 10A4 - Module
7D2 → 7DA - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2022, 2026. Not supported for 2023 to 2025.
Generator inverter temperature TUNDRA_GEN_INVERTER_T_7D2
- Request
22 10 A8 - Service 22
DID 10A8 - Module
7D2 → 7DA - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2022, 2026. Not supported for 2023 to 2025.
Generator inverter temperature after ignition on TUNDRA_GEN_INVERTER_T_AFTER_ON
- Request
22 10 A8 - Service 22
DID 10A8 - Module
7D2 → 7DA - Every
5 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2022, 2026. Not supported for 2023 to 2025.
Glass humidity TUNDRA_GLASS_HUMIDITY
- Request
21 B1 - Service 21
PID B1 - Module
7C4 → 7CC - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 20 ÷ 13107)- Range
- 0 to 100 %
- Unit
- %
In testing for 1999 to 2022, 2026. Not supported for 2023 to 2025.
Glass temperature TUNDRA_GLASS_T
- Request
21 AF - Service 21
PID AF - Module
7C4 → 7CC - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 9 ÷ 500 − 557.8)- Range
- -557 to 621 °F
- Unit
- °F
In testing for 1999 to 2022, 2026. Not supported for 2023 to 2025.
Hydraulic valve, communication open TUNDRA_HV_COMM_OPEN
- Request
21 BE - Service 21
PID BE - Module
7B0 → 7B8 - Every
1 s - Testing for 1999 to 2017, 2022 to 2026
Bit 17 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
In testing for 1999, 2001 to 2004, 2009, 2012 to 2013, 2016, 2022, 2026. Supported for 2018 to 2021. Not supported for 2000, 2005 to 2008, 2010 to 2011, 2014 to 2015, 2017, 2023 to 2025.
Idle control TUNDRA_IDLE_CTRL
- Request
21 E6 - Service 21
PID E6 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 1 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 1999 to 2022, 2026. Not supported for 2023 to 2025.
Idle spark advance control 1 TUNDRA_IDLE_SPARK_ADVN_CTRL_1
- Request
21 52 - Service 21
PID 52 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 16)- Range
- 0 to 15.93 °
- Unit
- °
In testing for 1999 to 2022, 2026. Not supported for 2023 to 2025.
Idle spark advance control 2 TUNDRA_IDLE_SPARK_ADVN_CTRL_2
- Request
21 52 - Service 21
PID 52 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
(val ÷ 16)- Range
- 0 to 15.93 °
- Unit
- °
In testing for 1999 to 2022, 2026. Not supported for 2023 to 2025.
Idle spark advance control 3 TUNDRA_IDLE_SPARK_ADVN_CTRL_3
- Request
21 52 - Service 21
PID 52 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
(val ÷ 16)- Range
- 0 to 15.93 °
- Unit
- °
In testing for 1999 to 2022, 2026. Not supported for 2023 to 2025.
Idle spark advance control 4 TUNDRA_IDLE_SPARK_ADVN_CTRL_4
- Request
21 52 - Service 21
PID 52 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
(val ÷ 16)- Range
- 0 to 15.93 °
- Unit
- °
In testing for 1999 to 2022, 2026. Not supported for 2023 to 2025.
Idle spark advance control, cylinder 1 TUNDRA_IDLE_SAC_CYL_1
- Request
22 10 78 - Service 22
DID 1078 - Module
700 → 708 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 6.25 ÷ 100)- Range
- 0 to 15.9375 °
- Unit
- °
In testing for 1999, 2001 to 2004, 2009, 2013, 2016, 2026. Not supported for 2000, 2005 to 2008, 2010 to 2012, 2014 to 2015, 2017 to 2025.
Idle spark advance control, cylinder 2 TUNDRA_IDLE_SAC_CYL_2
- Request
22 10 78 - Service 22
DID 1078 - Module
700 → 708 - Every
1 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
(val × 6.25 ÷ 100)- Range
- 0 to 15.9375 °
- Unit
- °
In testing for 1999, 2001 to 2004, 2009, 2013, 2016, 2026. Not supported for 2000, 2005 to 2008, 2010 to 2012, 2014 to 2015, 2017 to 2025.
Idle spark advance control, cylinder 3 TUNDRA_IDLE_SAC_CYL_3
- Request
22 10 78 - Service 22
DID 1078 - Module
700 → 708 - Every
1 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
(val × 6.25 ÷ 100)- Range
- 0 to 15.9375 °
- Unit
- °
In testing for 1999, 2001 to 2004, 2009, 2013, 2016, 2026. Not supported for 2000, 2005 to 2008, 2010 to 2012, 2014 to 2015, 2017 to 2025.
Idle spark advance control, cylinder 4 TUNDRA_IDLE_SAC_CYL_4
- Request
22 10 78 - Service 22
DID 1078 - Module
700 → 708 - Every
1 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
(val × 6.25 ÷ 100)- Range
- 0 to 15.9375 °
- Unit
- °
In testing for 1999, 2001 to 2004, 2009, 2013, 2016, 2026. Not supported for 2000, 2005 to 2008, 2010 to 2012, 2014 to 2015, 2017 to 2025.
Idle speed control learning TUNDRA_IDLE_SPD_CTRL
- Request
21 49 - Service 21
PID 49 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bit 93 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 1999 to 2022, 2026. Not supported for 2023 to 2025.
Idle speed control learning value, l/s TUNDRA_IDLE_SPD_CTRL_L_S
- Request
21 49 - Service 21
PID 49 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 72 to 87 of the reply, 16 bits.
- Formula
(val × 0.0012206912)- Range
- 0 to 79.99
- Unit
- Number
In testing for 1999 to 2022, 2026. Not supported for 2023 to 2025.
IG OFF elapsed time TUNDRA_IG_OFF_ELAPSED_TIME
- Request
21 37 - Service 21
PID 37 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 80 to 95 of the reply, 16 bits.
- Formula
(val × 10)- Range
- 0 to 655350 min
- Unit
- min
In testing for 1999 to 2022, 2026. Not supported for 2023 to 2025.
Ignition advance TUNDRA_SPARKADV_21
- Request
21 0E - Service 21
PID 0E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 2 − 64)- Range
- -64 to 63.5 °
- Unit
- °
In testing for 1999 to 2022, 2026. Not supported for 2023 to 2025.
Ignition timing advance TUNDRA_IGN_ADVANCEConfirmed
- Request
21 03 - Service 21
PID 03 - Module
7E0 → 7E8 - Every
1 s - Testing for 1999 to 2004, 2009, 2012 to 2013, 2016 to 2017, 2021 to 2026
Example reply from a 2020 Toyota Tundra.
Bits 48 to 55 of the reply, 8 bits.
0x97 = 151 → (151 ÷ 2 − 64) = 11.5 °
- Formula
(val ÷ 2 − 64)- Range
- -64 to 63.5 °
- Unit
- °
Confirmed for 2010 to 2011, 2014 to 2015, 2018 to 2020. In testing for 1999, 2001 to 2004, 2009, 2012 to 2013, 2016, 2022, 2026. Supported for 2005 to 2008. Not supported for 2000, 2017, 2021, 2023 to 2025.
Immobilizer communication on TUNDRA_IMMOBILIZER_ON
- Request
21 37 - Service 21
PID 37 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bit 120 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1999 to 2022, 2026. Not supported for 2023 to 2025.
Initial engine coolant temperature TUNDRA_INITIAL_ECT
- Request
21 37 - Service 21
PID 37 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 531 ÷ 850 − 40)- Range
- -40 to 119.3
- Unit
- Number
In testing for 1999 to 2022, 2026. Not supported for 2023 to 2025.
Initial intake air temperature TUNDRA_INITIAL_IAT
- Request
21 37 - Service 21
PID 37 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
(val × 5 ÷ 8 − 40)- Range
- -40 to 119 °C
- Unit
- °C
In testing for 1999 to 2022, 2026. Not supported for 2023 to 2025.
Injection TUNDRA_INJECTIONConfirmed
- Request
22 10 19 - Service 22
DID 1019 - Module
700 → 708 - Every
1 s - Testing for 1999 to 2022, 2026
Example reply from a 2025 Toyota Tundra.
Bits 0 to 7 of the reply, 8 bits.
0x01 = 1 → DIRECT
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
1 | DIRECT | Direct |
2 | BOTH | Both |
Confirmed for 2023 to 2025. In testing for 1999, 2001 to 2004, 2009, 2012 to 2013, 2016, 2022, 2026. Not supported for 2000, 2005 to 2008, 2010 to 2011, 2014 to 2015, 2017 to 2021.
Injection duration for cylinder 1 TUNDRA_INJ_DUR_CYL_1Confirmed
- Request
21 3C - Service 21
PID 3C - Module
7E0 → 7E8 - Every
1 s - Testing for 1999 to 2017, 2019 to 2026
Example reply from a 2018 Toyota Tundra.
Bits 16 to 31 of the reply, 16 bits.
0x0978 = 2424 → (2424 ÷ 1000) = 2.424 ms
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 ms
- Unit
- ms
Confirmed for 2018. In testing for 1999 to 2017, 2019 to 2022, 2026. Not supported for 2023 to 2025.
Injection feedback value 1 TUNDRA_INJ_FEEDBACK_1
- Request
22 11 2B - Service 22
DID 112B - Module
700 → 708 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 5 ÷ 32 − 20)- Range
- -20 to 15
- Unit
- Raw value
In testing for 1999 to 2007, 2009 to 2014, 2016 to 2017, 2020 to 2022, 2026. Not supported for 2008, 2015, 2018 to 2019, 2023 to 2025.
Injection feedback value 1 TUNDRA_INJ_FEEDBACK_1_700
- Request
22 11 B8 - Service 22
DID 11B8 - Module
700 → 708 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 332 ÷ 2125 − 19.99811765)- Range
- -19.9981 to 19.8418
- Unit
- Raw value
In testing for 1999 to 2007, 2009 to 2014, 2016 to 2017, 2020 to 2022, 2026. Not supported for 2008, 2015, 2018 to 2019, 2023 to 2025.
Injection feedback value 2 TUNDRA_INJ_FEEDBACK_2
- Request
22 11 2B - Service 22
DID 112B - Module
700 → 708 - Every
1 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
(val × 5 ÷ 32 − 20)- Range
- -20 to 15
- Unit
- Raw value
In testing for 1999 to 2007, 2009 to 2014, 2016 to 2017, 2020 to 2022, 2026. Not supported for 2008, 2015, 2018 to 2019, 2023 to 2025.
Injection feedback value 2 TUNDRA_INJ_FEEDBACK_2_700
- Request
22 11 B8 - Service 22
DID 11B8 - Module
700 → 708 - Every
1 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
(val × 332 ÷ 2125 − 19.99811765)- Range
- -19.9981 to 19.8418
- Unit
- Raw value
In testing for 1999 to 2007, 2009 to 2014, 2016 to 2017, 2020 to 2022, 2026. Not supported for 2008, 2015, 2018 to 2019, 2023 to 2025.
Injection feedback value 3 TUNDRA_INJ_FEEDBACK_3
- Request
22 11 2B - Service 22
DID 112B - Module
700 → 708 - Every
1 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
(val × 5 ÷ 32 − 20)- Range
- -20 to 15
- Unit
- Raw value
In testing for 1999 to 2007, 2009 to 2014, 2016 to 2017, 2020 to 2022, 2026. Not supported for 2008, 2015, 2018 to 2019, 2023 to 2025.
Injection feedback value 3 TUNDRA_INJ_FEEDBACK_3_700
- Request
22 11 B8 - Service 22
DID 11B8 - Module
700 → 708 - Every
1 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
(val × 332 ÷ 2125 − 19.99811765)- Range
- -19.9981 to 19.8418
- Unit
- Raw value
In testing for 1999 to 2007, 2009 to 2014, 2016 to 2017, 2020 to 2022, 2026. Not supported for 2008, 2015, 2018 to 2019, 2023 to 2025.
Injection feedback value 4 TUNDRA_INJ_FEEDBACK_4
- Request
22 11 2B - Service 22
DID 112B - Module
700 → 708 - Every
1 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
(val × 5 ÷ 32 − 20)- Range
- -20 to 15
- Unit
- Raw value
In testing for 1999 to 2007, 2009 to 2014, 2016 to 2017, 2020 to 2022, 2026. Not supported for 2008, 2015, 2018 to 2019, 2023 to 2025.
Injection feedback value 4 TUNDRA_INJ_FEEDBACK_4_700
- Request
22 11 B8 - Service 22
DID 11B8 - Module
700 → 708 - Every
1 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
(val × 332 ÷ 2125 − 19.99811765)- Range
- -19.9981 to 19.8418
- Unit
- Raw value
In testing for 1999 to 2007, 2009 to 2014, 2016 to 2017, 2020 to 2022, 2026. Not supported for 2008, 2015, 2018 to 2019, 2023 to 2025.
Injection feedback value 5 TUNDRA_INJ_FEEDBACK_5
- Request
22 11 B8 - Service 22
DID 11B8 - Module
700 → 708 - Every
1 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val × 332 ÷ 2125 − 19.99811765)- Range
- -19.9981 to 19.8418
- Unit
- Raw value
In testing for 1999 to 2007, 2009 to 2014, 2016 to 2017, 2020 to 2022, 2026. Not supported for 2008, 2015, 2018 to 2019, 2023 to 2025.
Injection feedback value 6 TUNDRA_INJ_FEEDBACK_6
- Request
22 11 B8 - Service 22
DID 11B8 - Module
700 → 708 - Every
1 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val × 332 ÷ 2125 − 19.99811765)- Range
- -19.9981 to 19.8418
- Unit
- Raw value
In testing for 1999 to 2007, 2009 to 2014, 2016 to 2017, 2020 to 2022, 2026. Not supported for 2008, 2015, 2018 to 2019, 2023 to 2025.
Injection volume TUNDRA_INJ_VOLConfirmed
- Request
22 10 17 - Service 22
DID 1017 - Module
700 → 708 - Every
1 s - Testing for 1999 to 2021, 2026
Example reply from a 2025 Toyota Tundra.
Bits 0 to 15 of the reply, 16 bits.
0x0000 = 0 → (0 ÷ 3200) = 0 L
- Formula
(val ÷ 3200)- Range
- 0 to 20 L
- Unit
- L
Confirmed for 2022 to 2025. In testing for 1999, 2001 to 2004, 2009, 2013, 2016, 2026. Not supported for 2000, 2005 to 2008, 2010 to 2012, 2014 to 2015, 2017 to 2021.
Injection volume - target TUNDRA_INJ_VOLUME_TGT
- Request
22 11 2C - Service 22
DID 112C - Module
700 → 708 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 19531 ÷ 1000000)- Range
- 0 to 15
- Unit
- Raw value
In testing for 1999 to 2007, 2009 to 2014, 2016 to 2017, 2020 to 2022, 2026. Not supported for 2008, 2015, 2018 to 2019, 2023 to 2025.
Injection volume 1 TUNDRA_INJ_VOLUME_1
- Request
22 11 8B - Service 22
DID 118B - Module
700 → 708 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 19531 ÷ 1000000 − 640)- Range
- -40 to 300
- Unit
- Raw value
In testing for 1999 to 2007, 2009 to 2014, 2016 to 2017, 2020 to 2022, 2026. Not supported for 2008, 2015, 2018 to 2019, 2023 to 2025.
Injection volume 2 TUNDRA_INJ_VOLUME_2
- Request
22 11 8B - Service 22
DID 118B - Module
700 → 708 - Every
1 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val × 19531 ÷ 1000000 − 640)- Range
- -40 to 300
- Unit
- Raw value
In testing for 1999 to 2007, 2009 to 2014, 2016 to 2017, 2020 to 2022, 2026. Not supported for 2008, 2015, 2018 to 2019, 2023 to 2025.
Injection volume 3 TUNDRA_INJ_VOLUME_3
- Request
22 11 8B - Service 22
DID 118B - Module
700 → 708 - Every
1 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
(val × 19531 ÷ 1000000 − 640)- Range
- -40 to 300
- Unit
- Raw value
In testing for 1999 to 2007, 2009 to 2014, 2016 to 2017, 2020 to 2022, 2026. Not supported for 2008, 2015, 2018 to 2019, 2023 to 2025.
Injection volume 5 TUNDRA_INJ_VOLUME_5
- Request
22 11 8B - Service 22
DID 118B - Module
700 → 708 - Every
1 s - Testing
Bits 48 to 63 of the reply, 16 bits.
- Formula
(val × 19531 ÷ 1000000 − 640)- Range
- -40 to 300
- Unit
- Raw value
In testing for 1999 to 2007, 2009 to 2014, 2016 to 2017, 2020 to 2022, 2026. Not supported for 2008, 2015, 2018 to 2019, 2023 to 2025.
Injection volume 6 TUNDRA_INJ_VOLUME_6
- Request
22 11 8B - Service 22
DID 118B - Module
700 → 708 - Every
1 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
(val × 19531 ÷ 1000000 − 640)- Range
- -40 to 300
- Unit
- Raw value
In testing for 1999 to 2007, 2009 to 2014, 2016 to 2017, 2020 to 2022, 2026. Not supported for 2008, 2015, 2018 to 2019, 2023 to 2025.
Injection volume per 10 injections, cylinder 1 TUNDRA_INJ_VOL_CYL_1Confirmed
- Request
21 3C - Service 21
PID 3C - Module
7E0 → 7E8 - Every
1 s - Testing for 1999 to 2017, 2019 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 32000000)- Range
- 0 to 0.002 L
- Unit
- L
Confirmed for 2018. In testing for 1999 to 2017, 2019 to 2022, 2026. Not supported for 2023 to 2025.
Injection volume total TUNDRA_INJ_VOLUME_TOT
- Request
22 11 2F - Service 22
DID 112F - Module
700 → 708 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 19531 ÷ 1000000 − 640)- Range
- -640 to 15
- Unit
- Raw value
In testing for 1999 to 2007, 2009 to 2014, 2016 to 2017, 2020 to 2022, 2026. Not supported for 2008, 2015, 2018 to 2019, 2023 to 2025.
Injector port TUNDRA_INJECTOR_PORTConfirmed
- Request
22 10 18 - Service 22
DID 1018 - Module
700 → 708 - Every
1 s - Testing for 1999 to 2022, 2026
Example reply from a 2025 Toyota Tundra.
Bits 0 to 15 of the reply, 16 bits.
0x0000 = 0 → (0 ÷ 1000) = 0 ms
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 ms
- Unit
- ms
Confirmed for 2023 to 2025. In testing for 1999, 2001 to 2004, 2009, 2012 to 2013, 2016, 2022, 2026. Not supported for 2000, 2005 to 2008, 2010 to 2011, 2014 to 2015, 2017 to 2021.
Injector pulse width TUNDRA_INJ_PW
- Request
21 E4 - Service 21
PID E4 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 163 ÷ 1275)- Range
- 0 to 32.6 ms
- Unit
- ms
In testing for 1999 to 2022, 2026. Not supported for 2023 to 2025.
Injector pulse width TUNDRA_INJ_WIDTH
- Request
21 F3 - Service 21
PID F3 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
(val × 16 ÷ 125)- Range
- 0 to 32.64 ms
- Unit
- ms
In testing for 1999 to 2022, 2026. Not supported for 2023 to 2025.
Input shaft speed TUNDRA_SPD_NIN
- Request
21 81 - Service 21
PID 81 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
(val × 50)- Range
- 0 to 12750 rpm
- Unit
- rpm
In testing for 1999 to 2022, 2026. Not supported for 2023 to 2025.
Intake air temperature TUNDRA_IATConfirmed
- Request
21 01 - Service 21
PID 01 - Module
7E0 → 7E8 - Every
1 s - Testing for 1999 to 2004, 2009, 2012 to 2013, 2022 to 2026
Example reply from a 2021 Toyota Tundra.
Bits 48 to 55 of the reply, 8 bits.
0x32 = 50 → (50 − 40) = 10 °C
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2010 to 2011, 2015, 2018 to 2021. In testing for 1999, 2001 to 2004, 2009, 2012 to 2013, 2022, 2026. Supported for 2005 to 2008. Not supported for 2000, 2023 to 2025.
Intake air temperature TUNDRA_IAT_21
- Request
21 0F - Service 21
PID 0F - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 1999 to 2022, 2026. Not supported for 2023 to 2025.
Intake air temperature, bank 1 sensor 1 TUNDRA_IAT_B1S1Confirmed
- Request
22 1F 77 - Service 22
DID 1F77 - Module
700 → 708 - Every
5 s - Testing for 1999 to 2022, 2026
Example reply from a 2025 Toyota Tundra.
Bits 8 to 15 of the reply, 8 bits.
0x2E = 46 → (46 − 40) = 6 °C
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2023 to 2025. In testing for 1999 to 2007, 2009 to 2014, 2016 to 2017, 2020 to 2022, 2026. Not supported for 2008, 2015, 2018 to 2019.
Intake air temperature, bank 1 sensor 2 TUNDRA_IAT_B1S2Confirmed
- Request
22 1F 77 - Service 22
DID 1F77 - Module
700 → 708 - Every
5 s - Testing for 1999 to 2022, 2026
Example reply from a 2025 Toyota Tundra.
Bits 16 to 23 of the reply, 8 bits.
0x00 = 0 → (0 − 40) = -40 °C
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2023 to 2025. In testing for 1999 to 2007, 2009 to 2014, 2016 to 2017, 2020 to 2022, 2026. Not supported for 2008, 2015, 2018 to 2019.
Intake VVT change angle, bank 1 TUNDRA_INTAKE_VVT_CHANGE_ANGLE_BANK_1Confirmed
- Request
22 10 87 - Service 22
DID 1087 - Module
700 → 708 - Every
1 s - Testing for 1999 to 2021, 2026
Example reply from a 2025 Toyota Tundra.
Bits 0 to 15 of the reply, 16 bits.
0x0000 = 0 → (0 × 639.9 ÷ 65535) = 0 °
- Formula
(val × 639.9 ÷ 65535)- Range
- 0 to 639.9 °
- Unit
- °
Confirmed for 2022 to 2025. In testing for 1999, 2001 to 2004, 2009, 2013, 2016, 2026. Not supported for 2000, 2005 to 2008, 2010 to 2012, 2014 to 2015, 2017 to 2021.
Intake VVT most over-retarded learn value, bank 1 TUNDRA_INTAKE_VVT_OVER_RET_LEARN_B1Confirmed
- Request
22 10 8D - Service 22
DID 108D - Module
700 → 708 - Every
3600 s - Testing for 1999 to 2022, 2026
Example reply from a 2025 Toyota Tundra.
Bits 0 to 15 of the reply, 16 bits.
0x0C1D = 3101 → (3101 × 639.99 ÷ 65535) = 30.283192 °
- Formula
(val × 639.99 ÷ 65535)- Range
- 0 to 639.99 °
- Unit
- °
Confirmed for 2023 to 2025. In testing for 1999, 2001 to 2004, 2009, 2012 to 2013, 2016, 2022, 2026. Not supported for 2000, 2005 to 2008, 2010 to 2011, 2014 to 2015, 2017 to 2021.
Intake VVT target angle B1 TUNDRA_INTAKE_VVT_TARGET_ANGLE_B1Confirmed
- Request
22 10 6F - Service 22
DID 106F - Module
700 → 708 - Every
1 s - Testing for 1999 to 2021, 2026
Example reply from a 2025 Toyota Tundra.
Bits 0 to 15 of the reply, 16 bits.
0x0000 = 0 → (0 × 639.9 ÷ 65535) = 0 °
- Formula
(val × 639.9 ÷ 65535)- Range
- 0 to 639.9 °
- Unit
- °
Confirmed for 2022 to 2025. In testing for 1999, 2001 to 2004, 2009, 2013, 2016, 2026. Not supported for 2000, 2005 to 2008, 2010 to 2012, 2014 to 2015, 2017 to 2021.
Integrated engine run time TUNDRA_INTEGRATED_ENG_RUNConfirmed
- Request
22 15 E8 - Service 22
DID 15E8 - Module
700 → 708 - Every
3600 s - Testing for 1999 to 2022, 2026
Example reply from a 2025 Toyota Tundra.
Bits 80 to 95 of the reply, 16 bits.
0x000A = 10 → 10 h
- Formula
val- Range
- 0 to 65535 h
- Unit
- h
Confirmed for 2023 to 2025. In testing for 1999 to 2007, 2009 to 2014, 2016 to 2017, 2020 to 2022, 2026. Not supported for 2008, 2015, 2018 to 2019.
Intercooler coolant temperature TUNDRA_INTERCOOLER_ECT
- Request
22 11 9C - Service 22
DID 119C - Module
700 → 708 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 1999 to 2007, 2009 to 2014, 2016 to 2017, 2020 to 2022, 2026. Not supported for 2008, 2015, 2018 to 2019, 2023 to 2025.
Intercooler water pump TUNDRA_INTERCOOLER_WATERConfirmed
- Request
22 28 20 - Service 22
DID 2820 - Module
700 → 708 - Every
1 s - Testing for 1999 to 2022, 2026
Example reply from a 2025 Toyota Tundra.
Bits 0 to 15 of the reply, 16 bits.
0x0000 = 0 → (0 × 80 ÷ 13107) = 0 %
- Formula
(val × 80 ÷ 13107)- Range
- 0 to 300 %
- Unit
- %
Confirmed for 2023 to 2025. In testing for 1999 to 2007, 2009 to 2014, 2016 to 2017, 2020 to 2022, 2026. Not supported for 2008, 2015, 2018 to 2019.
Internal temperature TUNDRA_ECU_INTERNAL_TConfirmed
- Request
22 10 5E - Service 22
DID 105E - Module
700 → 708 - Every
5 s - Testing for 1999 to 2021, 2026
Example reply from a 2025 Toyota Tundra.
Bits 0 to 7 of the reply, 8 bits.
0x19 = 25 → (25 − 40) = -15 °C
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2022 to 2025. In testing for 1999, 2001 to 2004, 2009, 2013, 2016, 2026. Not supported for 2000, 2005 to 2008, 2010 to 2012, 2014 to 2015, 2017 to 2021.
Inverter coolant temperature TUNDRA_INVRT_COOLANT_TConfirmed
- Request
22 10 B2 - Service 22
DID 10B2 - Module
7D2 → 7DA - Every
1 s - Testing for 2026
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- 0 to 100 °C
- Unit
- °C
Confirmed for 2022 to 2025. In testing for 2026. Not supported for 2000, 2005 to 2008, 2010 to 2012, 2014 to 2015, 2017 to 2021.
Inverter water pump duty TUNDRA_INVERTER_WATER_PMP
- Request
22 11 12 - Service 22
DID 1112 - Module
7D2 → 7DA - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 15259 ÷ 5000000)- Range
- 0 to 199 %
- Unit
- %
In testing for 2022, 2026. Not supported for 2023 to 2025.
Judge time engine ignition TUNDRA_JUDGE_TIME_ENG_IGN
- Request
21 49 - Service 21
PID 49 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 56 to 63 of the reply, 8 bits.
- Formula
(val ÷ 10)- Range
- 0 to 25.5 s
- Unit
- s
In testing for 1999 to 2022, 2026. Not supported for 2023 to 2025.
Judge time engine output TUNDRA_JUDGE_TIME_ENG
- Request
21 49 - Service 21
PID 49 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 64 to 71 of the reply, 8 bits.
- Formula
(val ÷ 10)- Range
- 0 to 25.5 s
- Unit
- s
In testing for 1999 to 2022, 2026. Not supported for 2023 to 2025.
Key cycle TUNDRA_KEY_CYCLEConfirmed
- Request
22 01 02 - Service 22
DID 0102 - Module
7D2 → 7DA - Every
1 s - Testing for 1999 to 2022, 2024, 2026
Example reply from a 2025 Toyota Tundra.
Bits 0 to 15 of the reply, 16 bits.
0x0D08 = 3336 → 3,336
- Formula
val- Range
- 0 to 65535
- Unit
- Number
Confirmed for 2023, 2025. In testing for 2022, 2026. Not supported for 2024.
Knock adjust TUNDRA_KNOCK_ADJUST
- Request
21 B2 - Service 21
PID B2 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 2048 ÷ 65535 − 64)- Range
- -64 to 1984 °
- Unit
- °
In testing for 1999 to 2022, 2026. Not supported for 2023 to 2025.
Knock adjust TUNDRA_KNOCK_ADJUST_7E0
- Request
21 37 - Service 21
PID 37 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
(val × 2048 ÷ 65535 − 1024)- Range
- -1024 to 1024 °
- Unit
- °
In testing for 1999 to 2022, 2026. Not supported for 2023 to 2025.
Knock correct learn value TUNDRA_KNOCK_CORRECT_LEARN
- Request
21 37 - Service 21
PID 37 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val ÷ 32 − 1024)- Range
- -1024 to 1023 °
- Unit
- °
In testing for 1999 to 2022, 2026. Not supported for 2023 to 2025.
Knock correction, learned value TUNDRA_KNOCK_CORRECT_LEARNED_VALUEConfirmed
- Request
22 10 5C - Service 22
DID 105C - Module
700 → 708 - Every
1 s - Testing for 1999 to 2021, 2026
Example reply from a 2025 Toyota Tundra.
Bits 0 to 15 of the reply, 16 bits.
0x819F = 33183 → (33183 × 312.5 ÷ 10000 − 1024) = 12.96875
- Formula
(val × 312.5 ÷ 10000 − 1024)- Range
- -1024 to 1023
- Unit
- Number
Confirmed for 2022 to 2025. In testing for 1999, 2001 to 2004, 2009, 2013, 2016, 2026. Not supported for 2000, 2005 to 2008, 2010 to 2012, 2014 to 2015, 2017 to 2021.
Knock feedback TUNDRA_KNOCK_FEEDBACK
- Request
21 B2 - Service 21
PID B2 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val × 2048 ÷ 65535 − 64)- Range
- -64 to 1984 °
- Unit
- °
In testing for 1999 to 2022, 2026. Not supported for 2023 to 2025.
Knock feedback TUNDRA_KNOCK_FEEDBACK_7E0
- Request
21 37 - Service 21
PID 37 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 48 to 63 of the reply, 16 bits.
- Formula
(val × 2048 ÷ 65535 − 1024)- Range
- -1024 to 1024 °
- Unit
- °
In testing for 1999 to 2022, 2026. Not supported for 2023 to 2025.
Knock feedback value TUNDRA_KNOCK_FEEDBACK_VALUEConfirmed
- Request
22 10 5C - Service 22
DID 105C - Module
700 → 708 - Every
1 s - Testing for 1999 to 2021, 2026
Example reply from a 2025 Toyota Tundra.
Bits 16 to 31 of the reply, 16 bits.
0x7FA0 = 32672 → (32672 × 312.5 ÷ 10000 − 1024) = -3
- Formula
(val × 312.5 ÷ 10000 − 1024)- Range
- -1024 to 1023
- Unit
- Number
Confirmed for 2022 to 2025. In testing for 1999, 2001 to 2004, 2009, 2013, 2016, 2026. Not supported for 2000, 2005 to 2008, 2010 to 2012, 2014 to 2015, 2017 to 2021.
Lock up state TUNDRA_LOCK_UP_STATEConfirmed
- Request
22 16 20 - Service 22
DID 1620 - Module
701 → 709 - Every
1 s - Testing for 1999 to 2022, 2026
Example reply from a 2025 Toyota Tundra.
Bit 7 of the reply.
0b0 = 0 → 0
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
Confirmed for 2023 to 2025. In testing for 1999, 2001 to 2004, 2009, 2012 to 2013, 2016, 2022, 2026. Not supported for 2000, 2005 to 2008, 2010 to 2011, 2014 to 2015, 2017 to 2021.
Long term fuel trim, bank 1 TUNDRA_LONG_FT_B1Confirmed
- Request
21 03 - Service 21
PID 03 - Module
7E0 → 7E8 - Every
1 s - Testing for 1999 to 2004, 2009, 2012 to 2013, 2016 to 2017, 2021 to 2026
Example reply from a 2020 Toyota Tundra.
Bits 24 to 31 of the reply, 8 bits.
0x85 = 133 → (133 × 200 ÷ 256 − 100) = 3.90625 %
- Formula
(val × 200 ÷ 256 − 100)- Range
- -100 to 99.21 %
- Unit
- %
Confirmed for 2010 to 2011, 2014 to 2015, 2018 to 2020. In testing for 1999, 2001 to 2004, 2009, 2012 to 2013, 2016, 2022, 2026. Supported for 2005 to 2008. Not supported for 2000, 2017, 2021, 2023 to 2025.
Long term fuel trim, bank 2 TUNDRA_LONG_FT_B2Confirmed
- Request
21 03 - Service 21
PID 03 - Module
7E0 → 7E8 - Every
1 s - Testing for 1999 to 2004, 2009, 2012 to 2013, 2016 to 2017, 2021 to 2026
Example reply from a 2020 Toyota Tundra.
Bits 40 to 47 of the reply, 8 bits.
0x81 = 129 → (129 × 200 ÷ 256 − 100) = 0.78125 %
- Formula
(val × 200 ÷ 256 − 100)- Range
- -100 to 99.21 %
- Unit
- %
Confirmed for 2010 to 2011, 2014 to 2015, 2018 to 2020. In testing for 1999, 2001 to 2004, 2009, 2012 to 2013, 2016, 2022, 2026. Supported for 2005 to 2008. Not supported for 2000, 2017, 2021, 2023 to 2025.
Long-term fuel trim, bank 1 TUNDRA_LTFT1_21
- Request
21 07 - Service 21
PID 07 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 0.7809803922 − 100)- Range
- -100 to 99.15 %
- Unit
- %
In testing for 1999 to 2022, 2026. Not supported for 2023 to 2025.
Manifold absolute pressure TUNDRA_MAP_7E0Confirmed
- Request
21 01 - Service 21
PID 01 - Module
7E0 → 7E8 - Every
1 s - Testing for 1999 to 2004, 2009, 2012 to 2013, 2022 to 2026
Example reply from a 2021 Toyota Tundra.
Bits 40 to 47 of the reply, 8 bits.
0x32 = 50 → 50 kPa
- Formula
val- Range
- 0 to 255 kPa
- Unit
- kPa
Confirmed for 2010 to 2011, 2015, 2018 to 2021. In testing for 1999, 2001 to 2004, 2009, 2012 to 2013, 2022, 2026. Supported for 2005 to 2008. Not supported for 2000, 2023 to 2025.
Manifold absolute pressure TUNDRA_MAP_7E0_V2Confirmed
- Request
21 01 - Service 21
PID 01 - Module
7E0 → 7E8 - Every
1 s - Testing for 2016
Example reply from a 2017 Toyota Tundra.
Bits 40 to 47 of the reply, 8 bits.
0x42 = 66 → 66 kPa
- Formula
val- Range
- 0 to 255 kPa
- Unit
- kPa
Confirmed for 2014, 2017. In testing for 2016.
Mass air flow TUNDRA_MAFConfirmed
Pelican can show this parameter as the mass air flow.
- Request
21 01 - Service 21
PID 01 - Module
7E0 → 7E8 - Every
1 s - Testing for 1999 to 2004, 2009, 2012 to 2013, 2022 to 2026
Example reply from a 2021 Toyota Tundra.
Bits 24 to 39 of the reply, 16 bits.
0x0243 = 579 → (579 ÷ 100) = 5.79 g/s
- Formula
(val ÷ 100)- Range
- 0 to 655.35 g/s
- Unit
- g/s
Confirmed for 2010 to 2011, 2015, 2018 to 2021. In testing for 1999, 2001 to 2004, 2009, 2012 to 2013, 2022, 2026. Supported for 2005 to 2008. Not supported for 2000, 2023 to 2025.
Mass air flow TUNDRA_MAF_21
- Request
21 10 - Service 21
PID 10 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655 g/s
- Unit
- g/s
In testing for 1999 to 2022, 2026. Not supported for 2023 to 2025.
Mass air flow TUNDRA_MAF_V2Confirmed
Pelican can show this parameter as the mass air flow.
- Request
21 01 - Service 21
PID 01 - Module
7E0 → 7E8 - Every
1 s - Testing for 2016
Example reply from a 2017 Toyota Tundra.
Bits 24 to 39 of the reply, 16 bits.
0x0230 = 560 → (560 ÷ 100) = 5.6 g/s
- Formula
(val ÷ 100)- Range
- 0 to 655.35 g/s
- Unit
- g/s
Confirmed for 2014, 2017. In testing for 2016.
Master cylinder open TUNDRA_MASTER_CYLINDER_OPENConfirmed
- Request
21 BE - Service 21
PID BE - Module
7B0 → 7B8 - Every
1 s - Testing for 1999 to 2017, 2022 to 2026
Example reply from a 2021 Toyota Tundra.
Bit 8 of the reply.
0b0 = 0 → 0
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2018 to 2021. In testing for 1999, 2001 to 2004, 2009, 2012 to 2013, 2016, 2022, 2026. Not supported for 2000, 2005 to 2008, 2010 to 2011, 2014 to 2015, 2017, 2023 to 2025.
Master cylinder sensor temperature TUNDRA_MASTER_CYL_TEMPConfirmed
- Request
22 10 06 - Service 22
DID 1006 - Module
7B0 → 7B8 - Every
5 s - Testing for 1999 to 2021, 2026
Example reply from a 2025 Toyota Tundra.
Bits 0 to 7 of the reply, 8 bits.
0x51 = 81 → (81 − 80) = 1 °C
- Formula
(val − 80)- Range
- -20 to 100 °C
- Unit
- °C
Confirmed for 2022 to 2025. In testing for 1999, 2001 to 2004, 2009, 2013, 2026. Not supported for 2000, 2005 to 2008, 2010 to 2012, 2014 to 2021.
Maximum generator inverter temperature TUNDRA_MAX_GEN_INVERTER_T
- Request
22 10 A8 - Service 22
DID 10A8 - Module
7D2 → 7DA - Every
5 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2022, 2026. Not supported for 2023 to 2025.
Maximum motor inverter temperature TUNDRA_MAX_MOTOR_INVERTER_TConfirmed
- Request
22 10 A5 - Service 22
DID 10A5 - Module
7D2 → 7DA - Every
5 s - Testing for 1999 to 2022, 2024, 2026
Example reply from a 2025 Toyota Tundra.
Bits 16 to 23 of the reply, 8 bits.
0x6E = 110 → (110 − 40) = 70 °C
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2023, 2025. In testing for 2022, 2026. Not supported for 2024.
Misfire count, all cylinders TUNDRA_MISFIRE_CNTConfirmed
- Request
22 10 A5 - Service 22
DID 10A5 - Module
700 → 708 - Every
1 s - Testing for 1999 to 2021, 2026
Example reply from a 2025 Toyota Tundra.
Bits 0 to 7 of the reply, 8 bits.
0x00 = 0 → 0
- Formula
val- Range
- 0 to 255
- Unit
- Number
Confirmed for 2022 to 2025. In testing for 1999, 2001 to 2004, 2009, 2013, 2016, 2026. Not supported for 2000, 2005 to 2008, 2010 to 2012, 2014 to 2015, 2017 to 2021.
Misfire count, cylinder 1 TUNDRA_MISFIRE_CYL1
- Request
22 10 A7 - Service 22
DID 10A7 - Module
700 → 708 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1999, 2001 to 2004, 2009, 2013, 2016, 2026. Not supported for 2000, 2005 to 2008, 2010 to 2012, 2014 to 2015, 2017 to 2025.
Misfire count, cylinder 2 TUNDRA_MISFIRE_CYL2
- Request
22 10 A7 - Service 22
DID 10A7 - Module
700 → 708 - Every
1 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1999, 2001 to 2004, 2009, 2013, 2016, 2026. Not supported for 2000, 2005 to 2008, 2010 to 2012, 2014 to 2015, 2017 to 2025.
Misfire count, cylinder 3 TUNDRA_MISFIRE_CYL3
- Request
22 10 A7 - Service 22
DID 10A7 - Module
700 → 708 - Every
1 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1999, 2001 to 2004, 2009, 2013, 2016, 2026. Not supported for 2000, 2005 to 2008, 2010 to 2012, 2014 to 2015, 2017 to 2025.
Misfire count, cylinder 4 TUNDRA_MISFIRE_CYL4
- Request
22 10 A7 - Service 22
DID 10A7 - Module
700 → 708 - Every
1 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1999, 2001 to 2004, 2009, 2013, 2016, 2026. Not supported for 2000, 2005 to 2008, 2010 to 2012, 2014 to 2015, 2017 to 2025.
Misfire load TUNDRA_MISFIRE_LOADConfirmed
- Request
22 10 AA - Service 22
DID 10AA - Module
700 → 708 - Every
1 s - Testing for 1999 to 2021, 2026
Example reply from a 2025 Toyota Tundra.
Bits 0 to 7 of the reply, 8 bits.
0x00 = 0 → (0 × 510 ÷ 255) = 0 %
- Formula
(val × 510 ÷ 255)- Range
- 0 to 510 %
- Unit
- %
Confirmed for 2022 to 2025. In testing for 1999, 2001 to 2004, 2009, 2013, 2016, 2026. Not supported for 2000, 2005 to 2008, 2010 to 2012, 2014 to 2015, 2017 to 2021.
Misfire margin TUNDRA_MISFIRE_MARGIN
- Request
22 10 AA - Service 22
DID 10AA - Module
700 → 708 - Every
1 s - Testing for 1999 to 2021, 2026
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val − 128)- Range
- -128 to 127 rpm
- Unit
- rpm
In testing for 1999, 2001 to 2004, 2009, 2013, 2016, 2026. Supported for 2022 to 2025. Not supported for 2000, 2005 to 2008, 2010 to 2012, 2014 to 2015, 2017 to 2021.
Misfire RPM TUNDRA_MISFIRE_RPM
- Request
22 10 AA - Service 22
DID 10AA - Module
700 → 708 - Every
1 s - Testing for 1999 to 2021, 2026
Bits 24 to 31 of the reply, 8 bits.
- Formula
(val × 6375 ÷ 255)- Range
- 0 to 6375 rpm
- Unit
- rpm
In testing for 1999, 2001 to 2004, 2009, 2013, 2016, 2026. Supported for 2022 to 2025. Not supported for 2000, 2005 to 2008, 2010 to 2012, 2014 to 2015, 2017 to 2021.
Misfire RPM TUNDRA_MISFIRE_RPM_7E0Confirmed
- Request
21 45 - Service 21
PID 45 - Module
7E0 → 7E8 - Every
1 s - Testing for 1999 to 2004, 2009, 2012 to 2013, 2016, 2022 to 2026
Example reply from a 2021 Toyota Tundra.
Bits 8 to 15 of the reply, 8 bits.
0x00 = 0 → (0 × 25) = 0 rpm
- Formula
(val × 25)- Range
- 0 to 6375 rpm
- Unit
- rpm
Confirmed for 2010 to 2011, 2014 to 2015, 2017 to 2021. In testing for 1999, 2001 to 2004, 2009, 2012 to 2013, 2016, 2022, 2026. Supported for 2005 to 2008. Not supported for 2000, 2023 to 2025.
Misfire test result, incomplete TUNDRA_MIS_TEST_RESULT
- Request
21 E3 - Service 21
PID E3 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 5 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1999 to 2022, 2026. Not supported for 2023 to 2025.
Model year TUNDRA_MODEL_YEAR
- Request
21 C1 - Service 21
PID C1 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 128 to 135 of the reply, 8 bits.
- Formula
(val + 1900)- Range
- 1900 to 2155
- Unit
- Number
In testing for 1999 to 2022, 2026. Not supported for 2023 to 2025.
Motor inverter temperature TUNDRA_MOTOR_INVERTER_TConfirmed
- Request
22 10 A5 - Service 22
DID 10A5 - Module
7D2 → 7DA - Every
5 s - Testing for 1999 to 2022, 2024, 2026
Example reply from a 2025 Toyota Tundra.
Bits 0 to 7 of the reply, 8 bits.
0x51 = 81 → (81 − 40) = 41 °C
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2023, 2025. In testing for 2022, 2026. Not supported for 2024.
Motor inverter temperature after ignition on TUNDRA_MOTOR_INVERTER_T_ONConfirmed
- Request
22 10 A5 - Service 22
DID 10A5 - Module
7D2 → 7DA - Every
5 s - Testing for 1999 to 2022, 2024, 2026
Example reply from a 2025 Toyota Tundra.
Bits 8 to 15 of the reply, 8 bits.
0x50 = 80 → (80 − 40) = 40 °C
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2023, 2025. In testing for 2022, 2026. Not supported for 2024.
Motor inverter, maximum temperature TUNDRA_M_INVRT_MAX_T
- Request
22 10 A6 - Service 22
DID 10A6 - Module
7D2 → 7DA - Every
1 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2026. Not supported for 2000, 2005 to 2008, 2010 to 2012, 2014 to 2015, 2017 to 2025.
Motor regenerative break torque TUNDRA_MOTOR_REGENERATIVE_BREAKConfirmed
- Request
22 10 69 - Service 22
DID 1069 - Module
7D2 → 7DA - Every
250 ms - Testing for 1999 to 2022, 2024, 2026
Example reply from a 2025 Toyota Tundra.
Bits 16 to 31 of the reply, 16 bits.
0x8000 = 32768 → (32768 ÷ 8 − 4096) = 0 kW
- Formula
(val ÷ 8 − 4096)- Range
- -4096 to 4095 kW
- Unit
- kW
Confirmed for 2023, 2025. In testing for 2022, 2026. Not supported for 2024.
Motor regenerative break torque, requested TUNDRA_MOTOR_REGENERATIVEConfirmed
- Request
22 10 69 - Service 22
DID 1069 - Module
7D2 → 7DA - Every
250 ms - Testing for 1999 to 2022, 2024, 2026
Example reply from a 2025 Toyota Tundra.
Bits 0 to 15 of the reply, 16 bits.
0x8000 = 32768 → (32768 ÷ 8 − 4096) = 0 kW
- Formula
(val ÷ 8 − 4096)- Range
- -4096 to 4095 kW
- Unit
- kW
Confirmed for 2023, 2025. In testing for 2022, 2026. Not supported for 2024.
Motor RPM TUNDRA_RPM_7D2Confirmed
- Request
22 10 A1 - Service 22
DID 10A1 - Module
7D2 → 7DA - Every
250 ms - Testing for 2026
Example reply from a 2025 Toyota Tundra.
Bits 0 to 15 of the reply, 16 bits.
0x7FFF = 32767 → (32767 − 32768) = -1 rpm
- Formula
(val − 32768)- Range
- -32768 to 32767 rpm
- Unit
- rpm
Confirmed for 2022 to 2025. In testing for 2026. Not supported for 2000, 2005 to 2008, 2010 to 2012, 2014 to 2015, 2017 to 2021.
Motor torque TUNDRA_TQConfirmed
- Request
22 10 A1 - Service 22
DID 10A1 - Module
7D2 → 7DA - Every
250 ms - Testing for 2026
Example reply from a 2025 Toyota Tundra.
Bits 48 to 63 of the reply, 16 bits.
0x7FFA = 32762 → (32762 ÷ 8 − 4096) = -0.75 N·m
- Formula
(val ÷ 8 − 4096)- Range
- -4096 to 4095 N·m
- Unit
- N·m
Confirmed for 2022 to 2025. In testing for 2026. Not supported for 2000, 2005 to 2008, 2010 to 2012, 2014 to 2015, 2017 to 2021.
O2 heater b1s2_active TUNDRA_O2_HEATER_B1S2
- Request
21 3A - Service 21
PID 3A - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 68 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1999 to 2022, 2026. Not supported for 2023 to 2025.
O2 heater current val bank 1 sensor 2 TUNDRA_O2_HEATER_CURR_VAL
- Request
21 3A - Service 21
PID 3A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 48 to 63 of the reply, 16 bits.
- Formula
(val ÷ 13107)- Range
- 0 to 4.999 A
- Unit
- A
In testing for 1999 to 2022, 2026. Not supported for 2023 to 2025.
Open side malfunction on TUNDRA_OPEN_SIDE_ONConfirmed
- Request
21 41 - Service 21
PID 41 - Module
7E0 → 7E8 - Every
3600 s - Testing for 1999 to 2017, 2020 to 2026
Example reply from a 2019 Toyota Tundra.
Bit 145 of the reply.
0b0 = 0 → 0
- Formula
val- Range
- 0 to 1
- Unit
- Number
Confirmed for 2018 to 2019. In testing for 1999 to 2017, 2020 to 2022, 2026. Not supported for 2023 to 2025.
Output shaft speed TUNDRA_SPD_NOUT
- Request
21 81 - Service 21
PID 81 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val × 50)- Range
- 0 to 12750 rpm
- Unit
- rpm
In testing for 1999 to 2022, 2026. Not supported for 2023 to 2025.
OXS1, A/FS2 test result, incomplete TUNDRA_OXS1_FS2_TEST_RESULT
- Request
21 E3 - Service 21
PID E3 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 7 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 1999 to 2022, 2026. Not supported for 2023 to 2025.
Oxygen sensor voltage, bank 1 sensor 1 TUNDRA_O2S11_V
- Request
21 14 - Service 21
PID 14 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 0.0049960784)- Range
- 0 to 1.27 V
- Unit
- V
In testing for 1999 to 2022, 2026. Not supported for 2023 to 2025.
Oxygen sensor voltage, bank 1 sensor 2 TUNDRA_O2S_B1S2Confirmed
- Request
21 04 - Service 21
PID 04 - Module
7E0 → 7E8 - Every
1 s - Testing for 1999 to 2004, 2009, 2012 to 2013, 2016, 2022 to 2026
Example reply from a 2021 Toyota Tundra.
Bits 144 to 151 of the reply, 8 bits.
0x9C = 156 → (156 × 5 ÷ 1000) = 0.78 V
- Formula
(val × 5 ÷ 1000)- Range
- 0 to 1.275 V
- Unit
- V
Confirmed for 2010 to 2011, 2014 to 2015, 2017 to 2021. In testing for 1999, 2001 to 2004, 2009, 2012 to 2013, 2016, 2022, 2026. Supported for 2005 to 2008. Not supported for 2000, 2023 to 2025.
PM accumulation ratio - bank 1 TUNDRA_PM_ACCUMULATION_RAT_1
- Request
22 11 05 - Service 22
DID 1105 - Module
700 → 708 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 2)- Range
- 0 to 15 %
- Unit
- %
In testing for 1999 to 2007, 2009 to 2014, 2016 to 2017, 2020 to 2022, 2026. Not supported for 2008, 2015, 2018 to 2019, 2023 to 2025.
Purge cut vacuum switching valve duty TUNDRA_PURGE_CUT_VSV_DUTY
- Request
21 3A - Service 21
PID 3A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val × 25 ÷ 4096)- Range
- 0 to 399.9 %
- Unit
- %
In testing for 1999 to 2022, 2026. Not supported for 2023 to 2025.
Racing operation TUNDRA_RACING_OPERATION
- Request
21 49 - Service 21
PID 49 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bit 90 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 1999 to 2022, 2026. Not supported for 2023 to 2025.
Real engine torque TUNDRA_REAL_ENG_TQ
- Request
22 10 09 - Service 22
DID 1009 - Module
7B1 → 7B9 - Every
250 ms - Testing
Bits 32 to 47 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 32)- Range
- -20 to 150 N·m
- Unit
- N·m
In testing for 1999 to 2007, 2009 to 2014, 2016 to 2017, 2020 to 2022, 2026. Not supported for 2008, 2015, 2018 to 2019, 2023 to 2025.
Rear motor inverter, coolant temperature TUNDRA_RM_INVRT_COOL_T
- Request
22 10 A6 - Service 22
DID 10A6 - Module
7D2 → 7DA - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2026. Not supported for 2000, 2005 to 2008, 2010 to 2012, 2014 to 2015, 2017 to 2025.
Rear motor regenerative break torque TUNDRA_REAR_MOTOR_REGENERATIVE
- Request
22 10 6A - Service 22
DID 106A - Module
7D2 → 7DA - Every
250 ms - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val ÷ 8 − 4096)- Range
- -4096 to 4095 kW
- Unit
- kW
In testing for 2022, 2026. Not supported for 2023 to 2025.
Rear motor regenerative break torque, requested TUNDRA_REAR_MOTOR
- Request
22 10 6A - Service 22
DID 106A - Module
7D2 → 7DA - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 8 − 4096)- Range
- -4096 to 4095 kW
- Unit
- kW
In testing for 2022, 2026. Not supported for 2023 to 2025.
Rear motor speed TUNDRA_RM_TQ_REQ
- Request
22 10 A2 - Service 22
DID 10A2 - Module
7D2 → 7DA - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val − 32768)- Range
- -32768 to 32767 rpm
- Unit
- rpm
In testing for 2026. Not supported for 2000, 2005 to 2008, 2010 to 2012, 2014 to 2015, 2017 to 2025.
Rear motor torque TUNDRA_RM_TQ
- Request
22 10 A2 - Service 22
DID 10A2 - Module
7D2 → 7DA - Every
250 ms - Testing
Bits 48 to 63 of the reply, 16 bits.
- Formula
(val ÷ 8 − 4096)- Range
- -4096 to 4095 N·m
- Unit
- N·m
In testing for 2026. Not supported for 2000, 2005 to 2008, 2010 to 2012, 2014 to 2015, 2017 to 2025.
Regulator pressure TUNDRA_REGULATOR_P
- Request
21 53 - Service 21
PID 53 - Module
7C4 → 7CC - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 375105 ÷ 25500 − 456.68)- Range
- -456.68 to 3294 kPa
- Unit
- kPa
In testing for 1999, 2001 to 2004, 2009, 2012 to 2013, 2016, 2022, 2026. Not supported for 2000, 2005 to 2008, 2010 to 2011, 2014 to 2015, 2017 to 2021, 2023 to 2025.
Request engine run time TUNDRA_REQ_ENG_RUN_TIME
- Request
21 49 - Service 21
PID 49 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 48 to 55 of the reply, 8 bits.
- Formula
(val ÷ 10)- Range
- 0 to 25.5 s
- Unit
- s
In testing for 1999 to 2022, 2026. Not supported for 2023 to 2025.
Request warm-up TUNDRA_REQ_WARM_UP
- Request
21 49 - Service 21
PID 49 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bit 89 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 1999 to 2022, 2026. Not supported for 2023 to 2025.
Requested engine torque TUNDRA_REQ_ENG_TQ
- Request
21 49 - Service 21
PID 49 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4)- Range
- 0 to 16383
- Unit
- Number
In testing for 1999 to 2022, 2026. Not supported for 2023 to 2025.
Rough idle, cylinder 1 TUNDRA_ROUGH_IDLE_CYL_1Confirmed
- Request
22 10 84 - Service 22
DID 1084 - Module
700 → 708 - Every
1 s - Testing for 1999 to 2022, 2026
Example reply from a 2025 Toyota Tundra.
Bits 0 to 7 of the reply, 8 bits.
0x01 = 1 → 1 °
- Formula
val- Range
- 0 to 255 °
- Unit
- °
Confirmed for 2023 to 2025. In testing for 1999, 2001 to 2004, 2009, 2012 to 2013, 2016, 2022, 2026. Not supported for 2000, 2005 to 2008, 2010 to 2011, 2014 to 2015, 2017 to 2021.
Rough idle, cylinder 2 TUNDRA_ROUGH_IDLE_CYL_2Confirmed
- Request
22 10 84 - Service 22
DID 1084 - Module
700 → 708 - Every
1 s - Testing for 1999 to 2022, 2026
Example reply from a 2025 Toyota Tundra.
Bits 8 to 15 of the reply, 8 bits.
0x00 = 0 → 0 °
- Formula
val- Range
- 0 to 255 °
- Unit
- °
Confirmed for 2023 to 2025. In testing for 1999, 2001 to 2004, 2009, 2012 to 2013, 2016, 2022, 2026. Not supported for 2000, 2005 to 2008, 2010 to 2011, 2014 to 2015, 2017 to 2021.
Rough idle, cylinder 3 TUNDRA_ROUGH_IDLE_CYL_3Confirmed
- Request
22 10 84 - Service 22
DID 1084 - Module
700 → 708 - Every
1 s - Testing for 1999 to 2022, 2026
Example reply from a 2025 Toyota Tundra.
Bits 16 to 23 of the reply, 8 bits.
0x3F = 63 → 63 °
- Formula
val- Range
- 0 to 255 °
- Unit
- °
Confirmed for 2023 to 2025. In testing for 1999, 2001 to 2004, 2009, 2012 to 2013, 2016, 2022, 2026. Not supported for 2000, 2005 to 2008, 2010 to 2011, 2014 to 2015, 2017 to 2021.
Rough idle, cylinder 4 TUNDRA_ROUGH_IDLE_CYL_4Confirmed
- Request
22 10 84 - Service 22
DID 1084 - Module
700 → 708 - Every
1 s - Testing for 1999 to 2022, 2026
Example reply from a 2025 Toyota Tundra.
Bits 24 to 31 of the reply, 8 bits.
0x00 = 0 → 0 °
- Formula
val- Range
- 0 to 255 °
- Unit
- °
Confirmed for 2023 to 2025. In testing for 1999, 2001 to 2004, 2009, 2012 to 2013, 2016, 2022, 2026. Not supported for 2000, 2005 to 2008, 2010 to 2011, 2014 to 2015, 2017 to 2021.
Short term fuel trim, bank 1 TUNDRA_SHORT_FT_B1Confirmed
Pelican can show this parameter as the short term fuel trim.
- Request
21 03 - Service 21
PID 03 - Module
7E0 → 7E8 - Every
1 s - Testing for 1999 to 2004, 2009, 2012 to 2013, 2016 to 2017, 2021 to 2026
Example reply from a 2020 Toyota Tundra.
Bits 16 to 23 of the reply, 8 bits.
0x7A = 122 → (122 × 200 ÷ 256 − 100) = -4.6875 %
- Formula
(val × 200 ÷ 256 − 100)- Range
- -100 to 99.21 %
- Unit
- %
Confirmed for 2010 to 2011, 2014 to 2015, 2018 to 2020. In testing for 1999, 2001 to 2004, 2009, 2012 to 2013, 2016, 2022, 2026. Supported for 2005 to 2008. Not supported for 2000, 2017, 2021, 2023 to 2025.
Short term fuel trim, bank 2 TUNDRA_SHORT_FT_B2Confirmed
Pelican can show this parameter as the short term fuel trim.
- Request
21 03 - Service 21
PID 03 - Module
7E0 → 7E8 - Every
1 s - Testing for 1999 to 2004, 2009, 2012 to 2013, 2016 to 2017, 2021 to 2026
Example reply from a 2020 Toyota Tundra.
Bits 32 to 39 of the reply, 8 bits.
0x79 = 121 → (121 × 200 ÷ 256 − 100) = -5.46875 %
- Formula
(val × 200 ÷ 256 − 100)- Range
- -100 to 99.21 %
- Unit
- %
Confirmed for 2010 to 2011, 2014 to 2015, 2018 to 2020. In testing for 1999, 2001 to 2004, 2009, 2012 to 2013, 2016, 2022, 2026. Supported for 2005 to 2008. Not supported for 2000, 2017, 2021, 2023 to 2025.
Starter relay on TUNDRA_STARTER_RELAY_ON
- Request
21 39 - Service 21
PID 39 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bit 47 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1999 to 2022, 2026. Not supported for 2023 to 2025.
Steering angle TUNDRA_STEER_ANG
- Request
22 10 09 - Service 22
DID 1009 - Module
7B1 → 7B9 - Every
250 ms - Testing
Bits 48 to 63 of the reply, 16 bits.
- Formula
(val ÷ 10 − 3276.8)- Range
- -20 to 150 °
- Unit
- °
In testing for 1999 to 2007, 2009 to 2014, 2016 to 2017, 2020 to 2022, 2026. Not supported for 2008, 2015, 2018 to 2019, 2023 to 2025.
Stroke open TUNDRA_STROKE_OPENConfirmed
- Request
21 BE - Service 21
PID BE - Module
7B0 → 7B8 - Every
1 s - Testing for 1999 to 2017, 2022 to 2026
Example reply from a 2021 Toyota Tundra.
Bit 10 of the reply.
0b0 = 0 → 0
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2018 to 2021. In testing for 1999, 2001 to 2004, 2009, 2012 to 2013, 2016, 2022, 2026. Not supported for 2000, 2005 to 2008, 2010 to 2011, 2014 to 2015, 2017, 2023 to 2025.
Synchronize stroke sensor position TUNDRA_SYNCHRONIZE_STROKE
- Request
22 16 34 - Service 22
DID 1634 - Module
701 → 709 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 256 ÷ 65535)- Range
- 0 to 256 mm
- Unit
- mm
In testing for 1999 to 2007, 2009 to 2014, 2016 to 2017, 2020 to 2022, 2026. Not supported for 2008, 2015, 2018 to 2019, 2023 to 2025.
System guard on TUNDRA_SYSTEM_GUARD_ONConfirmed
- Request
21 41 - Service 21
PID 41 - Module
7E0 → 7E8 - Every
3600 s - Testing for 1999 to 2017, 2020 to 2026
Example reply from a 2019 Toyota Tundra.
Bit 144 of the reply.
0b1 = 1 → 1
- Formula
val- Range
- 0 to 1
- Unit
- Number
Confirmed for 2018 to 2019. In testing for 1999 to 2017, 2020 to 2022, 2026. Not supported for 2023 to 2025.
Throttle fully close learn TUNDRA_THROTTLE_FULLY_CLOSEConfirmed
- Request
21 41 - Service 21
PID 41 - Module
7E0 → 7E8 - Every
3600 s - Testing for 1999 to 2017, 2020 to 2026
Bits 112 to 119 of the reply, 8 bits.
- Formula
(val × 5 ÷ 256)- Range
- 0 to 4.98 V
- Unit
- V
Confirmed for 2018 to 2019. In testing for 1999 to 2017, 2020 to 2022, 2026. Not supported for 2023 to 2025.
Throttle idle position on TUNDRA_THROTTLE_IDLE_POS_ONConfirmed
- Request
21 41 - Service 21
PID 41 - Module
7E0 → 7E8 - Every
3600 s - Testing for 1999 to 2017, 2020 to 2026
Example reply from a 2019 Toyota Tundra.
Bit 149 of the reply.
0b1 = 1 → 1
- Formula
val- Range
- 0 to 1
- Unit
- Number
Confirmed for 2018 to 2019. In testing for 1999 to 2017, 2020 to 2022, 2026. Not supported for 2023 to 2025.
Throttle motor current TUNDRA_THROTTLE_MOTORConfirmed
- Request
21 41 - Service 21
PID 41 - Module
7E0 → 7E8 - Every
3600 s - Testing for 1999 to 2017, 2020 to 2026
Bits 136 to 143 of the reply, 8 bits.
- Formula
(val × 5 ÷ 64)- Range
- 0 to 19.9 A
- Unit
- A
Confirmed for 2018 to 2019. In testing for 1999 to 2017, 2020 to 2022, 2026. Not supported for 2023 to 2025.
Throttle motor duty, close TUNDRA_THROTTLE_MOTOR_DUTY_CLOSEConfirmed
- Request
21 41 - Service 21
PID 41 - Module
7E0 → 7E8 - Every
3600 s - Testing for 1999 to 2017, 2020 to 2026
Example reply from a 2019 Toyota Tundra.
Bits 128 to 135 of the reply, 8 bits.
0x05 = 5 → 5 %
- Formula
val- Range
- 0 to 255 %
- Unit
- %
Confirmed for 2018 to 2019. In testing for 1999 to 2017, 2020 to 2022, 2026. Not supported for 2023 to 2025.
Throttle motor duty, open TUNDRA_THROTTLE_MOTOR_DUTY_OPENConfirmed
- Request
21 41 - Service 21
PID 41 - Module
7E0 → 7E8 - Every
3600 s - Testing for 1999 to 2017, 2020 to 2026
Example reply from a 2019 Toyota Tundra.
Bits 120 to 127 of the reply, 8 bits.
0x00 = 0 → 0 %
- Formula
val- Range
- 0 to 255 %
- Unit
- %
Confirmed for 2018 to 2019. In testing for 1999 to 2017, 2020 to 2022, 2026. Not supported for 2023 to 2025.
Throttle position TUNDRA_THROTTLE_21
- Request
21 11 - Service 21
PID 11 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 1999 to 2022, 2026. Not supported for 2023 to 2025.
Throttle position command TUNDRA_THROTTLE_POS_COMMANDConfirmed
- Request
21 41 - Service 21
PID 41 - Module
7E0 → 7E8 - Every
3600 s - Testing for 1999 to 2017, 2020 to 2026
Example reply from a 2019 Toyota Tundra.
Bits 32 to 39 of the reply, 8 bits.
0x30 = 48 → (48 × 5 ÷ 256) = 0.9375 V
- Formula
(val × 5 ÷ 256)- Range
- 0 to 4.98 V
- Unit
- V
Confirmed for 2018 to 2019. In testing for 1999 to 2017, 2020 to 2022, 2026. Not supported for 2023 to 2025.
Throttle position, number 1 TUNDRA_THROTTLE_POS_NUMBER_1Confirmed
- Request
21 41 - Service 21
PID 41 - Module
7E0 → 7E8 - Every
3600 s - Testing for 1999 to 2017, 2020 to 2026
Example reply from a 2019 Toyota Tundra.
Bits 88 to 95 of the reply, 8 bits.
0x30 = 48 → (48 × 5 ÷ 256) = 0.9375 V
- Formula
(val × 5 ÷ 256)- Range
- 0 to 4.98 V
- Unit
- V
Confirmed for 2018 to 2019. In testing for 1999 to 2017, 2020 to 2022, 2026. Not supported for 2023 to 2025.
Throttle position, number 2 TUNDRA_THROTTLE_POS_NUMBER_2Confirmed
- Request
21 41 - Service 21
PID 41 - Module
7E0 → 7E8 - Every
3600 s - Testing for 1999 to 2017, 2020 to 2026
Example reply from a 2019 Toyota Tundra.
Bits 96 to 103 of the reply, 8 bits.
0x82 = 130 → (130 × 5 ÷ 256) = 2.539063 V
- Formula
(val × 5 ÷ 256)- Range
- 0 to 4.98 V
- Unit
- V
Confirmed for 2018 to 2019. In testing for 1999 to 2017, 2020 to 2022, 2026. Not supported for 2023 to 2025.
Throttle require position TUNDRA_THROTTLE_REQUIRE_POSConfirmed
- Request
21 41 - Service 21
PID 41 - Module
7E0 → 7E8 - Every
3600 s - Testing for 1999 to 2017, 2020 to 2026
Example reply from a 2019 Toyota Tundra.
Bits 104 to 111 of the reply, 8 bits.
0x30 = 48 → (48 × 5 ÷ 256) = 0.9375 V
- Formula
(val × 5 ÷ 256)- Range
- 0 to 4.98 V
- Unit
- V
Confirmed for 2018 to 2019. In testing for 1999 to 2017, 2020 to 2022, 2026. Not supported for 2023 to 2025.
Throttle sensor open position 1 TUNDRA_THROTTLE_SENS_OPEN_1Confirmed
- Request
21 41 - Service 21
PID 41 - Module
7E0 → 7E8 - Every
3600 s - Testing for 1999 to 2017, 2020 to 2026
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 5 ÷ 256)- Range
- 0 to 4.98 V
- Unit
- V
Confirmed for 2018 to 2019. In testing for 1999 to 2017, 2020 to 2022, 2026. Not supported for 2023 to 2025.
Throttle sensor open position 2 TUNDRA_THROTTLE_SENS_OPEN_2Confirmed
- Request
21 41 - Service 21
PID 41 - Module
7E0 → 7E8 - Every
3600 s - Testing for 1999 to 2017, 2020 to 2026
Bits 8 to 15 of the reply, 8 bits.
- Formula
(val × 5 ÷ 256)- Range
- 0 to 4.98 V
- Unit
- V
Confirmed for 2018 to 2019. In testing for 1999 to 2017, 2020 to 2022, 2026. Not supported for 2023 to 2025.
Throttle sensor position TUNDRA_THROTTLE_SENSOR_POSITIONConfirmed
- Request
21 01 - Service 21
PID 01 - Module
7E0 → 7E8 - Every
1 s - Testing for 1999 to 2004, 2009, 2012 to 2013, 2022 to 2026
Example reply from a 2021 Toyota Tundra.
Bits 112 to 119 of the reply, 8 bits.
0x00 = 0 → (0 × 100 ÷ 255) = 0 %
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2010 to 2011, 2015, 2018 to 2021. In testing for 1999, 2001 to 2004, 2009, 2012 to 2013, 2022, 2026. Supported for 2005 to 2008. Not supported for 2000, 2023 to 2025.
Throttle sensor position TUNDRA_THROTTLE_SENSOR_POSITION_V2Confirmed
- Request
21 01 - Service 21
PID 01 - Module
7E0 → 7E8 - Every
1 s - Testing for 2016
Example reply from a 2017 Toyota Tundra.
Bits 104 to 111 of the reply, 8 bits.
0x00 = 0 → (0 × 100 ÷ 255) = 0 %
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2014, 2017. In testing for 2016.
Total fuel trim, bank 1 TUNDRA_TOT_FT_1Confirmed
- Request
21 3C - Service 21
PID 3C - Module
7E0 → 7E8 - Every
1 s - Testing for 1999 to 2017, 2019 to 2026
Example reply from a 2018 Toyota Tundra.
Bits 32 to 39 of the reply, 8 bits.
0x80 = 128 → (128 × 100 ÷ 256 − 50) = 0 %
- Formula
(val × 100 ÷ 256 − 50)- Range
- -50 to 49.6 %
- Unit
- %
Confirmed for 2018. In testing for 1999 to 2017, 2019 to 2022, 2026. Not supported for 2023 to 2025.
Transaxle oil temperature TUNDRA_TRANSAXLE_OIL_TConfirmed
- Request
22 10 40 - Service 22
DID 1040 - Module
7D2 → 7DA - Every
1 s - Testing for 2026
Example reply from a 2025 Toyota Tundra.
Bits 16 to 23 of the reply, 8 bits.
0x84 = 132 → (132 − 40) = 92 °C
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2022 to 2025. In testing for 2026. Not supported for 2000, 2005 to 2008, 2010 to 2012, 2014 to 2015, 2017 to 2021.
Transmission fluid pan temperature TUNDRA_TF1_PANConfirmed
Pelican can show this parameter as the transmission fluid temperature.
- Request
22 16 27 - Service 22
DID 1627 - Module
701 → 709 - Every
5 s - Testing for 1999 to 2021, 2026
Example reply from a 2025 Toyota Tundra.
Bits 0 to 15 of the reply, 16 bits.
0x2800 = 10240 → (10240 × 0.00703125 − 40) = 32 °F
- Formula
(val × 0.00703125 − 40)- Range
- -40 to 350 °F
- Unit
- °F
Confirmed for 2022 to 2025. In testing for 1999, 2001 to 2004, 2009, 2013, 2026. Not supported for 2000, 2005 to 2008, 2010 to 2012, 2014 to 2021.
Transmission fluid post-converter temperature TUNDRA_TF2_CONV
Pelican can show this parameter as the transmission fluid temperature.
- Request
22 16 28 - Service 22
DID 1628 - Module
701 → 709 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.00703125 − 40)- Range
- -40 to 350 °F
- Unit
- °F
In testing for 1999, 2001 to 2004, 2009, 2013, 2026. Not supported for 2000, 2005 to 2008, 2010 to 2012, 2014 to 2025.
Transmission fluid temperature TUNDRA_ATF_TEMP_700
Pelican can show this parameter as the transmission fluid temperature.
- Request
22 16 38 - Service 22
DID 1638 - Module
700 → 708 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 1999, 2001 to 2004, 2009, 2013, 2026. Not supported for 2000, 2005 to 2008, 2010 to 2012, 2014 to 2025.
Transmission output shaft speed TUNDRA_TRANS_OUT_RPM
- Request
21 BD - Service 21
PID BD - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 50)- Range
- 0 to 12750 rpm
- Unit
- rpm
In testing for 1999 to 2022, 2026. Not supported for 2023 to 2025.
Turbine speed TUNDRA_SPD_NT
- Request
21 81 - Service 21
PID 81 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 50)- Range
- 0 to 12750 rpm
- Unit
- rpm
In testing for 1999 to 2022, 2026. Not supported for 2023 to 2025.
Valvematic current angle TUNDRA_VALVEMATIC_CURRENT
- Request
21 31 - Service 21
PID 31 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 5 ÷ 512)- Range
- 0 to 639.9 °
- Unit
- °
In testing for 1999 to 2022, 2026. Not supported for 2023 to 2025.
Valvematic, target angle TUNDRA_VALVEMATIC_TGT_ANG
- Request
21 3A - Service 21
PID 3A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 5 ÷ 512)- Range
- 0 to 639.9 °
- Unit
- °
In testing for 1999 to 2022, 2026. Not supported for 2023 to 2025.
Variable valve timing aim angle 1 TUNDRA_VARIABLE_VLV_TIM_AIM_1Confirmed
- Request
21 44 - Service 21
PID 44 - Module
7E0 → 7E8 - Every
1 s - Testing for 1999 to 2017, 2019 to 2026
Example reply from a 2018 Toyota Tundra.
Bits 0 to 15 of the reply, 16 bits.
0x1FE9 = 8169 → (8169 × 1333 ÷ 218450) = 49.847915 %
- Formula
(val × 1333 ÷ 218450)- Range
- 0 to 399 %
- Unit
- %
Confirmed for 2018. In testing for 1999 to 2017, 2019 to 2022, 2026. Not supported for 2023 to 2025.
Variable valve timing change angle 1 TUNDRA_VARIABLE_VLV_TIM_1Confirmed
- Request
21 44 - Service 21
PID 44 - Module
7E0 → 7E8 - Every
1 s - Testing for 1999 to 2017, 2019 to 2026
Bits 32 to 47 of the reply, 16 bits.
- Formula
(val × 0.0097642481)- Range
- 0 to 639 °
- Unit
- °
Confirmed for 2018. In testing for 1999 to 2017, 2019 to 2022, 2026. Not supported for 2023 to 2025.
Variable valve timing control status 1 on TUNDRA_VARIABLE_VLV_TIM_1_ON
- Request
21 39 - Service 21
PID 39 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bit 22 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1999 to 2022, 2026. Not supported for 2023 to 2025.
Variable valve timing oil control valve duty 1 TUNDRA_VARIABLE_VLV_TIM_OIL_1Confirmed
- Request
21 44 - Service 21
PID 44 - Module
7E0 → 7E8 - Every
1 s - Testing for 1999 to 2017, 2019 to 2026
Example reply from a 2018 Toyota Tundra.
Bits 16 to 31 of the reply, 16 bits.
0x1CA9 = 7337 → (7337 × 0.0061020829) = 44.770982 %
- Formula
(val × 0.0061020829)- Range
- 0 to 399 %
- Unit
- %
Confirmed for 2018. In testing for 1999 to 2017, 2019 to 2022, 2026. Not supported for 2023 to 2025.
Variable valve timing oil temperature TUNDRA_VVTOTConfirmed
- Request
21 51 - Service 21
PID 51 - Module
7E0 → 7E8 - Every
1 s - Testing for 1999 to 2009, 2011, 2013, 2022 to 2026
Example reply from a 2021 Toyota Tundra.
Bits 56 to 63 of the reply, 8 bits.
0x83 = 131 → (131 − 40) = 91 °C
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2010, 2012, 2014 to 2021. In testing for 1999, 2001 to 2004, 2009, 2013, 2026. Not supported for 2000, 2005 to 2008, 2011, 2022 to 2025.
Variable valve timing opening angle bank 1 TUNDRA_VVT_IE_OPENING_ANGLE_BANK_1
- Request
22 28 43 - Service 22
DID 2843 - Module
700 → 708 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 %
- Unit
- %
In testing for 1999, 2001 to 2004, 2009, 2012 to 2013, 2016, 2022, 2026. Not supported for 2000, 2005 to 2008, 2010 to 2011, 2014 to 2015, 2017 to 2021, 2023 to 2025.
Vehicle speed TUNDRA_VSS_21
- Request
21 0D - Service 21
PID 0D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 km/h
- Unit
- km/h
In testing for 1999 to 2022, 2026. Not supported for 2023 to 2025.
Vehicle speed sensor test result, incomplete TUNDRA_SPD_TEST_RESULT
- Request
21 E3 - Service 21
PID E3 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 2 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1999 to 2022, 2026. Not supported for 2023 to 2025.
Engine › Catalyst
Catalyst temperature, bank 1 sensor 1 TUNDRA_CAT_T_11Confirmed
- Request
22 1F 3C - Service 22
DID 1F3C - Module
700 → 708 - Every
5 s - Testing for 1999 to 2021, 2026
Example reply from a 2025 Toyota Tundra.
Bits 0 to 15 of the reply, 16 bits.
0x01DE = 478 → (478 ÷ 10 − 40) = 7.8 °C
- Formula
(val ÷ 10 − 40)- Range
- -40 to 6513.5 °C
- Unit
- °C
Confirmed for 2022 to 2025. In testing for 1999, 2001 to 2004, 2009, 2013, 2016, 2026. Not supported for 2000, 2005 to 2008, 2010 to 2012, 2014 to 2015, 2017 to 2021.
Catalyst temperature, bank 1 sensor 2 TUNDRA_CAT_T_12Confirmed
- Request
22 1F 3E - Service 22
DID 1F3E - Module
700 → 708 - Every
5 s - Testing for 1999 to 2021, 2026
Example reply from a 2025 Toyota Tundra.
Bits 0 to 15 of the reply, 16 bits.
0x01D9 = 473 → (473 ÷ 10 − 40) = 7.3 °C
- Formula
(val ÷ 10 − 40)- Range
- -40 to 6513.5 °C
- Unit
- °C
Confirmed for 2022 to 2025. In testing for 1999, 2001 to 2004, 2009, 2013, 2016, 2026. Not supported for 2000, 2005 to 2008, 2010 to 2012, 2014 to 2015, 2017 to 2021.
Engine › Misfires
All cylinders misfire count TUNDRA_ALL_CYLINDERS_MISFIRE_CNTConfirmed
- Request
21 45 - Service 21
PID 45 - Module
7E0 → 7E8 - Every
1 s - Testing for 1999 to 2004, 2009, 2012 to 2013, 2016, 2022 to 2026
Example reply from a 2021 Toyota Tundra.
Bits 56 to 63 of the reply, 8 bits.
0x00 = 0 → 0
- Formula
val- Range
- 0 to 255
- Unit
- Number
Confirmed for 2010 to 2011, 2014 to 2015, 2017 to 2021. In testing for 1999, 2001 to 2004, 2009, 2012 to 2013, 2016, 2022, 2026. Supported for 2005 to 2008. Not supported for 2000, 2023 to 2025.
Cylinder #1 misfire count TUNDRA_CYL1_MISFIRE_CNTConfirmed
- Request
21 45 - Service 21
PID 45 - Module
7E0 → 7E8 - Every
1 s - Testing for 1999 to 2004, 2009, 2012 to 2013, 2016, 2022 to 2026
Example reply from a 2021 Toyota Tundra.
Bits 24 to 31 of the reply, 8 bits.
0x00 = 0 → 0
- Formula
val- Range
- 0 to 255
- Unit
- Number
Confirmed for 2010 to 2011, 2014 to 2015, 2017 to 2021. In testing for 1999, 2001 to 2004, 2009, 2012 to 2013, 2016, 2022, 2026. Supported for 2005 to 2008. Not supported for 2000, 2023 to 2025.
Cylinder #2 misfire count TUNDRA_CYL2_MISFIRE_CNTConfirmed
- Request
21 45 - Service 21
PID 45 - Module
7E0 → 7E8 - Every
1 s - Testing for 1999 to 2004, 2009, 2012 to 2013, 2016, 2022 to 2026
Example reply from a 2021 Toyota Tundra.
Bits 32 to 39 of the reply, 8 bits.
0x00 = 0 → 0
- Formula
val- Range
- 0 to 255
- Unit
- Number
Confirmed for 2010 to 2011, 2014 to 2015, 2017 to 2021. In testing for 1999, 2001 to 2004, 2009, 2012 to 2013, 2016, 2022, 2026. Supported for 2005 to 2008. Not supported for 2000, 2023 to 2025.
Cylinder #3 misfire count TUNDRA_CYL3_MISFIRE_CNTConfirmed
- Request
21 45 - Service 21
PID 45 - Module
7E0 → 7E8 - Every
1 s - Testing for 1999 to 2004, 2009, 2012 to 2013, 2016, 2022 to 2026
Example reply from a 2021 Toyota Tundra.
Bits 40 to 47 of the reply, 8 bits.
0x00 = 0 → 0
- Formula
val- Range
- 0 to 255
- Unit
- Number
Confirmed for 2010 to 2011, 2014 to 2015, 2017 to 2021. In testing for 1999, 2001 to 2004, 2009, 2012 to 2013, 2016, 2022, 2026. Supported for 2005 to 2008. Not supported for 2000, 2023 to 2025.
Cylinder #4 misfire count TUNDRA_CYL4_MISFIRE_CNTConfirmed
- Request
21 45 - Service 21
PID 45 - Module
7E0 → 7E8 - Every
1 s - Testing for 1999 to 2004, 2009, 2012 to 2013, 2016, 2022 to 2026
Example reply from a 2021 Toyota Tundra.
Bits 48 to 55 of the reply, 8 bits.
0x00 = 0 → 0
- Formula
val- Range
- 0 to 255
- Unit
- Number
Confirmed for 2010 to 2011, 2014 to 2015, 2017 to 2021. In testing for 1999, 2001 to 2004, 2009, 2012 to 2013, 2016, 2022, 2026. Supported for 2005 to 2008. Not supported for 2000, 2023 to 2025.
Misfire load TUNDRA_MISFIRE_LOAD_7E0Confirmed
- Request
21 45 - Service 21
PID 45 - Module
7E0 → 7E8 - Every
1 s - Testing for 1999 to 2004, 2009, 2012 to 2013, 2016, 2022 to 2026
Example reply from a 2021 Toyota Tundra.
Bits 16 to 23 of the reply, 8 bits.
0x00 = 0 → (0 × 4 ÷ 256) = 0
- Formula
(val × 4 ÷ 256)- Range
- 0 to 3.98
- Unit
- Number
Confirmed for 2010 to 2011, 2014 to 2015, 2017 to 2021. In testing for 1999, 2001 to 2004, 2009, 2012 to 2013, 2016, 2022, 2026. Supported for 2005 to 2008. Not supported for 2000, 2023 to 2025.
Misfire margin TUNDRA_MISFIRE_MARGIN_7E0Confirmed
- Request
21 45 - Service 21
PID 45 - Module
7E0 → 7E8 - Every
1 s - Testing for 1999 to 2004, 2009, 2012 to 2013, 2016, 2022 to 2026
Example reply from a 2021 Toyota Tundra.
Bits 80 to 87 of the reply, 8 bits.
0x00 = 0 → (0 − 128) = -128 %
- Formula
(val − 128)- Range
- -128 to 127 %
- Unit
- %
Confirmed for 2010 to 2011, 2014 to 2015, 2017 to 2021. In testing for 1999, 2001 to 2004, 2009, 2012 to 2013, 2016, 2022, 2026. Supported for 2005 to 2008. Not supported for 2000, 2023 to 2025.
Engine › OxygenSensors
Lambda value, Equivalence Ratio Bank 1, Sensor 1 LAMBDA11_CURRENTSAE J1979Confirmed
Pelican can show this parameter as the O2 lambda.
- Request
01 34 - Service 01
PID 34 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 32768)- Range
- 0 to 1.99
- Unit
- Number
Confirmed for 2007, 2019, 2021, 2024. Supported for 2006, 2008, 2010 to 2012, 2014 to 2015, 2017 to 2018, 2020, 2023, 2025.
Lambda value, Equivalence Ratio Bank 1, Sensor 1 LAMBDA11_VOLTSAE J1979Confirmed
Pelican can show this parameter as the O2 lambda.
- Request
01 24 - Service 01
PID 24 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 32768)- Range
- 0 to 1.99
- Unit
- Number
Confirmed for 2005 to 2007, 2019, 2021. Supported for 2008, 2010 to 2018, 2020.
Wide Range O2S Current, O2 Sensor Bank 1, Sensor 1 O2S11_CURRENTSAE J1979Confirmed
- Request
01 34 - Service 01
PID 34 - Module
7E0 → 7E8 - Every
250 ms
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val ÷ 256 − 128)- Range
- -128 to 127.996 mA
- Unit
- mA
Confirmed for 2007, 2019, 2021, 2024. Supported for 2006, 2008, 2010 to 2012, 2014 to 2015, 2017 to 2018, 2020, 2023, 2025.
Wide Range O2S Voltage, O2 Sensor Bank 1, Sensor 1 O2S11_VOLTSAE J1979Confirmed
- Request
01 24 - Service 01
PID 24 - Module
7E0 → 7E8 - Every
250 ms
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val ÷ 8196)- Range
- 0 to 7.999 V
- Unit
- V
Confirmed for 2005 to 2007, 2019, 2021. Supported for 2008, 2010 to 2018, 2020.