Toyota Tundra

Engine parameters

The Toyota Tundra has 277 engine parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

Air-fuel equivalence ratio, bank 1 sensor 1 TUNDRA_AF_LAMBDA_B1S1Confirmed

Pelican can show this parameter as the O2 lambda.

  • Request21 04
  • Service 21PID 04
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1999 to 2004, 2009, 2012 to 2013, 2016, 2022 to 2026

Example reply from a 2021 Toyota Tundra.

Bits 16 to 31 of the reply, 16 bits.

0x7FF2 = 32754 → (32754 × 1.99 ÷ 65535) = 0.99459

Formula
(val × 1.99 ÷ 65535)
Range
0 to 1.99
Unit
Number

Confirmed for 2010 to 2011, 2014 to 2015, 2017 to 2021. In testing for 1999, 2001 to 2004, 2009, 2012 to 2013, 2016, 2022, 2026. Supported for 2005 to 2008. Not supported for 2000, 2023 to 2025.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

A/F heater duty bank 1 sensor 1 TUNDRA_F_HEATER_DUTY_B1S1

  • Request21 3A
  • Service 21PID 3A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
(val × 25 ÷ 4096)
Range
0 to 399.9 %
Unit
%

In testing for 1999 to 2022, 2026. Not supported for 2023 to 2025.

A/F ratio learn value high, bank 1 TUNDRA_AF_LEARN_HIGH_PORT_B1Confirmed

  • Request22 10 A2
  • Service 22DID 10A2
  • Module700 → 708
  • Every3600 s
  • Testing for 1999 to 2022, 2026

Example reply from a 2025 Toyota Tundra.

Bits 32 to 39 of the reply, 8 bits.

0x8E = 142 → (142 × 100 ÷ 255 − 50) = 5.686275 %

Formula
(val × 100 ÷ 255 − 50)
Range
-50 to 50 %
Unit
%

Confirmed for 2023 to 2025. In testing for 1999, 2001 to 2004, 2009, 2012 to 2013, 2016, 2022, 2026. Not supported for 2000, 2005 to 2008, 2010 to 2011, 2014 to 2015, 2017 to 2021.

A/F ratio learn value idle, bank 1 TUNDRA_AF_LEARN_IDLE_PORT_B1Confirmed

  • Request22 10 A2
  • Service 22DID 10A2
  • Module700 → 708
  • Every3600 s
  • Testing for 1999 to 2022, 2026

Example reply from a 2025 Toyota Tundra.

Bits 0 to 7 of the reply, 8 bits.

0x74 = 116 → (116 × 100 ÷ 255 − 50) = -4.509804 %

Formula
(val × 100 ÷ 255 − 50)
Range
-50 to 50 %
Unit
%

Confirmed for 2023 to 2025. In testing for 1999, 2001 to 2004, 2009, 2012 to 2013, 2016, 2022, 2026. Not supported for 2000, 2005 to 2008, 2010 to 2011, 2014 to 2015, 2017 to 2021.

A/F ratio learn value low, bank 1 TUNDRA_AF_LEARN_LOW_PORT_B1Confirmed

  • Request22 10 A2
  • Service 22DID 10A2
  • Module700 → 708
  • Every3600 s
  • Testing for 1999 to 2022, 2026

Example reply from a 2025 Toyota Tundra.

Bits 8 to 15 of the reply, 8 bits.

0x73 = 115 → (115 × 100 ÷ 255 − 50) = -4.901961 %

Formula
(val × 100 ÷ 255 − 50)
Range
-50 to 50 %
Unit
%

Confirmed for 2023 to 2025. In testing for 1999, 2001 to 2004, 2009, 2012 to 2013, 2016, 2022, 2026. Not supported for 2000, 2005 to 2008, 2010 to 2011, 2014 to 2015, 2017 to 2021.

A/F ratio learn value mid.1, bank 1 TUNDRA_AF_LEARN_MID1_PORT_B1Confirmed

  • Request22 10 A2
  • Service 22DID 10A2
  • Module700 → 708
  • Every3600 s
  • Testing for 1999 to 2022, 2026

Example reply from a 2025 Toyota Tundra.

Bits 16 to 23 of the reply, 8 bits.

0x96 = 150 → (150 × 100 ÷ 255 − 50) = 8.823529 %

Formula
(val × 100 ÷ 255 − 50)
Range
-50 to 50 %
Unit
%

Confirmed for 2023 to 2025. In testing for 1999, 2001 to 2004, 2009, 2012 to 2013, 2016, 2022, 2026. Not supported for 2000, 2005 to 2008, 2010 to 2011, 2014 to 2015, 2017 to 2021.

A/F ratio learn value mid.2, bank 1 TUNDRA_AF_LEARN_MID2_PORT_B1Confirmed

  • Request22 10 A2
  • Service 22DID 10A2
  • Module700 → 708
  • Every3600 s
  • Testing for 1999 to 2022, 2026

Example reply from a 2025 Toyota Tundra.

Bits 24 to 31 of the reply, 8 bits.

0x97 = 151 → (151 × 100 ÷ 255 − 50) = 9.215686 %

Formula
(val × 100 ÷ 255 − 50)
Range
-50 to 50 %
Unit
%

Confirmed for 2023 to 2025. In testing for 1999, 2001 to 2004, 2009, 2012 to 2013, 2016, 2022, 2026. Not supported for 2000, 2005 to 2008, 2010 to 2011, 2014 to 2015, 2017 to 2021.

A/F ratio learned high, bank 1 TUNDRA_A_F_RATIO_LEARNED_HIGH_BANK_1Confirmed

  • Request22 10 2A
  • Service 22DID 102A
  • Module700 → 708
  • Every3600 s
  • Testing for 1999 to 2021, 2026

Example reply from a 2025 Toyota Tundra.

Bits 32 to 39 of the reply, 8 bits.

0x88 = 136 → (136 × 100 ÷ 255 − 50) = 3.333333 %

Formula
(val × 100 ÷ 255 − 50)
Range
-50 to 50 %
Unit
%

Confirmed for 2022 to 2025. In testing for 1999, 2001 to 2004, 2009, 2013, 2016, 2026. Not supported for 2000, 2005 to 2008, 2010 to 2012, 2014 to 2015, 2017 to 2021.

A/F ratio learned idle, bank 1 TUNDRA_A_F_RATIO_LEARNED_IDLE_BANK_1Confirmed

  • Request22 10 2A
  • Service 22DID 102A
  • Module700 → 708
  • Every3600 s
  • Testing for 1999 to 2021, 2026

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 100 ÷ 255 − 50)
Range
-50 to 50 %
Unit
%

Confirmed for 2022 to 2025. In testing for 1999, 2001 to 2004, 2009, 2013, 2016, 2026. Not supported for 2000, 2005 to 2008, 2010 to 2012, 2014 to 2015, 2017 to 2021.

A/F ratio learned low, bank 1 TUNDRA_A_F_RATIO_LEARNED_LOW_BANK_1Confirmed

  • Request22 10 2A
  • Service 22DID 102A
  • Module700 → 708
  • Every3600 s
  • Testing for 1999 to 2021, 2026

Bits 8 to 15 of the reply, 8 bits.

Formula
(val × 100 ÷ 255 − 50)
Range
-50 to 50 %
Unit
%

Confirmed for 2022 to 2025. In testing for 1999, 2001 to 2004, 2009, 2013, 2016, 2026. Not supported for 2000, 2005 to 2008, 2010 to 2012, 2014 to 2015, 2017 to 2021.

A/F ratio learned mid 1, bank 1 TUNDRA_A_F_RATIO_LEARNED_MID_1_BANK_1Confirmed

  • Request22 10 2A
  • Service 22DID 102A
  • Module700 → 708
  • Every3600 s
  • Testing for 1999 to 2021, 2026

Bits 16 to 23 of the reply, 8 bits.

Formula
(val × 100 ÷ 255 − 50)
Range
-50 to 50 %
Unit
%

Confirmed for 2022 to 2025. In testing for 1999, 2001 to 2004, 2009, 2013, 2016, 2026. Not supported for 2000, 2005 to 2008, 2010 to 2012, 2014 to 2015, 2017 to 2021.

A/F ratio learned mid 2, bank 1 TUNDRA_A_F_RATIO_LEARNED_MID_2_BANK_1Confirmed

  • Request22 10 2A
  • Service 22DID 102A
  • Module700 → 708
  • Every3600 s
  • Testing for 1999 to 2021, 2026

Example reply from a 2025 Toyota Tundra.

Bits 24 to 31 of the reply, 8 bits.

0x8A = 138 → (138 × 100 ÷ 255 − 50) = 4.117647 %

Formula
(val × 100 ÷ 255 − 50)
Range
-50 to 50 %
Unit
%

Confirmed for 2022 to 2025. In testing for 1999, 2001 to 2004, 2009, 2013, 2016, 2026. Not supported for 2000, 2005 to 2008, 2010 to 2012, 2014 to 2015, 2017 to 2021.

A/F test results 1, incomplete TUNDRA_F_TEST_RESULTS_1

  • Request21 E3
  • Service 21PID E3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 15 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 1999 to 2022, 2026. Not supported for 2023 to 2025.

Accessory relay on TUNDRA_ACC_RELAY_ON

  • Request21 39
  • Service 21PID 39
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bit 46 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 1999 to 2022, 2026. Not supported for 2023 to 2025.

Accumulator open TUNDRA_ACCUMULATOR_OPEN

  • Request21 BE
  • Service 21PID BE
  • Module7B0 → 7B8
  • Every1 s
  • Testing for 1999 to 2017, 2022 to 2026

Bit 16 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

In testing for 1999, 2001 to 2004, 2009, 2012 to 2013, 2016, 2022, 2026. Supported for 2018 to 2021. Not supported for 2000, 2005 to 2008, 2010 to 2011, 2014 to 2015, 2017, 2023 to 2025.

Acoustic control induction system vacuum switching valve on TUNDRA_ACIS_VSV_ON

  • Request21 39
  • Service 21PID 39
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 1999 to 2022, 2026. Not supported for 2023 to 2025.

Actual engine torque TQ_ACTSAE J1979Confirmed

  • Request01 62
  • Service 01PID 62
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 125)
Range
-125 to 130 %
Unit
%

Confirmed for 2021. Supported for 2024.

Actual engine torque TUNDRA_ACT_ENG_TQ

  • Request21 49
  • Service 21PID 49
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 24 to 39 of the reply, 16 bits.

Formula
(val − 32768)
Range
-32768 to 32767 N·m
Unit
N·m

In testing for 1999 to 2022, 2026. Not supported for 2023 to 2025.

Actuator power supply on TUNDRA_ACTUATOR_POWER_SUP_ONConfirmed

  • Request21 41
  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing for 1999 to 2017, 2020 to 2026

Example reply from a 2019 Toyota Tundra.

Bit 146 of the reply.

0b1 = 1 → 1

Formula
val
Range
0 to 1
Unit
Number

Confirmed for 2018 to 2019. In testing for 1999 to 2017, 2020 to 2022, 2026. Not supported for 2023 to 2025.

Air conditioning compressor TUNDRA_AC_COMP

  • Request21 E6
  • Service 21PID E6
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 1999 to 2022, 2026. Not supported for 2023 to 2025.

Air conditioning power consumption TUNDRA_AC_POWER_CONSConfirmed

  • Request22 10 6E
  • Service 22DID 106E
  • Module7D2 → 7DA
  • Every1 s
  • Testing for 1999 to 2022, 2024, 2026

Example reply from a 2025 Toyota Tundra.

Bits 0 to 7 of the reply, 8 bits.

0x0B = 11 → (11 ÷ 20) = 0.55 kW

Formula
(val ÷ 20)
Range
0 to 12.75 kW
Unit
kW

Confirmed for 2023, 2025. In testing for 2022, 2026. Not supported for 2024.

Air flow rate from mass air flow sensor MAFSAE J1979Confirmed

Pelican can show this parameter as the mass air flow.

  • Request01 10
  • Service 01PID 10
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 655.35 g/s
Unit
g/s

Confirmed for 2008, 2014 to 2015, 2019. Supported for 2005 to 2007, 2010 to 2013, 2016 to 2018, 2020 to 2021.

Air mix servo target pulse, driver TUNDRA_AIR_MIX_SERVO_TARG_D

  • Request21 41
  • Service 21PID 41
  • Module7C4 → 7CC
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1999 to 2022, 2026. Not supported for 2023 to 2025.

Air mix servo, actual pulse, d TUNDRA_AIR_MIX_SERVO_ACT_D

  • Request21 41
  • Service 21PID 41
  • Module7C4 → 7CC
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1999 to 2022, 2026. Not supported for 2023 to 2025.

Air-fuel equivalence ratio, bank 1 sensor 1 TUNDRA_AF_LAMBDA_B1S1Confirmed

Pelican can show this parameter as the O2 lambda.

  • Request21 04
  • Service 21PID 04
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1999 to 2004, 2009, 2012 to 2013, 2016, 2022 to 2026

Example reply from a 2021 Toyota Tundra.

Bits 16 to 31 of the reply, 16 bits.

0x7FF2 = 32754 → (32754 × 1.99 ÷ 65535) = 0.99459

Formula
(val × 1.99 ÷ 65535)
Range
0 to 1.99
Unit
Number

Confirmed for 2010 to 2011, 2014 to 2015, 2017 to 2021. In testing for 1999, 2001 to 2004, 2009, 2012 to 2013, 2016, 2022, 2026. Supported for 2005 to 2008. Not supported for 2000, 2023 to 2025.

Air-fuel sensor current, bank 1 sensor 1 TUNDRA_AFS_I_B1S1Confirmed

  • Request21 04
  • Service 21PID 04
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1999 to 2004, 2009, 2012 to 2013, 2016, 2022 to 2026

Bits 96 to 111 of the reply, 16 bits.

Formula
(val ÷ 256 − 128)
Range
-128 to 127.99 mA
Unit
mA

Confirmed for 2010 to 2011, 2014 to 2015, 2017 to 2021. In testing for 1999, 2001 to 2004, 2009, 2012 to 2013, 2016, 2022, 2026. Supported for 2005 to 2008. Not supported for 2000, 2023 to 2025.

Air-fuel sensor voltage, bank 1 sensor 1 TUNDRA_AFS_V_B1S1Confirmed

  • Request21 04
  • Service 21PID 04
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1999 to 2004, 2009, 2012 to 2013, 2016, 2022 to 2026

Example reply from a 2021 Toyota Tundra.

Bits 32 to 47 of the reply, 16 bits.

0x68A9 = 26793 → (26793 × 7.99 ÷ 65535) = 3.266591 V

Formula
(val × 7.99 ÷ 65535)
Range
0 to 7.99 V
Unit
V

Confirmed for 2010 to 2011, 2014 to 2015, 2017 to 2021. In testing for 1999, 2001 to 2004, 2009, 2012 to 2013, 2016, 2022, 2026. Supported for 2005 to 2008. Not supported for 2000, 2023 to 2025.

Alt voltage - active test TUNDRA_ALT_VOL_ACTIVE_TEST

  • Request21 42
  • Service 21PID 42
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
(val × 5 ÷ 4096)
Range
0 to 79.998 V
Unit
V

In testing for 1999 to 2022, 2026. Not supported for 2023 to 2025.

Alt voltage - non active test TUNDRA_ALT_VOL_NON_ACTIVE

  • Request21 42
  • Service 21PID 42
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
(val × 5 ÷ 4096)
Range
0 to 79.998 V
Unit
V

In testing for 1999 to 2022, 2026. Not supported for 2023 to 2025.

Alternator output duty TUNDRA_ALTERNATOR_OUTPUT

  • Request21 42
  • Service 21PID 42
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
(val × 25 ÷ 4096)
Range
0 to 399.9 %
Unit
%

In testing for 1999 to 2022, 2026. Not supported for 2023 to 2025.

Alternator output duty cycle TUNDRA_ALT_DUTY_CYCLEConfirmed

  • Request22 15 FA
  • Service 22DID 15FA
  • Module700 → 708
  • Every1 s
  • Testing for 1999 to 2022, 2026

Example reply from a 2025 Toyota Tundra.

Bits 0 to 15 of the reply, 16 bits.

0x0000 = 0 → (0 ÷ 164) = 0 %

Formula
(val ÷ 164)
Range
0 to 399 %
Unit
%

Confirmed for 2023 to 2025. In testing for 1999, 2001 to 2004, 2009, 2012 to 2013, 2016, 2022, 2026. Not supported for 2000, 2005 to 2008, 2010 to 2011, 2014 to 2015, 2017 to 2021.

Ambient temperature TUNDRA_AAT_7D2Confirmed

  • Request22 1F 46
  • Service 22DID 1F46
  • Module7D2 → 7DA
  • Every1 s
  • Testing for 2026

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2022 to 2025. In testing for 2026. Not supported for 2000, 2005 to 2008, 2010 to 2012, 2014 to 2015, 2017 to 2021.

Automatic transmission fluid thermal degradation estimate TUNDRA_ATF_THERMAL_DEGRAD_ESTConfirmed

  • Request22 16 2B
  • Service 22DID 162B
  • Module701 → 709
  • Every1 s
  • Testing for 1999 to 2022, 2026

Example reply from a 2025 Toyota Tundra.

Bits 0 to 15 of the reply, 16 bits.

0x0022 = 34 → 34

Formula
val
Range
0 to 65535
Unit
Number

Confirmed for 2023 to 2025. In testing for 1999, 2001 to 2004, 2009, 2012 to 2013, 2016, 2022, 2026. Not supported for 2000, 2005 to 2008, 2010 to 2011, 2014 to 2015, 2017 to 2021.

Barometric pressure TUNDRA_BAROConfirmed

  • Request21 01
  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1999 to 2004, 2009, 2012 to 2013, 2022 to 2026

Example reply from a 2021 Toyota Tundra.

Bits 56 to 63 of the reply, 8 bits.

0x62 = 98 → 98 kPa

Formula
val
Range
0 to 255 kPa
Unit
kPa

Confirmed for 2010 to 2011, 2015, 2018 to 2021. In testing for 1999, 2001 to 2004, 2009, 2012 to 2013, 2022, 2026. Supported for 2005 to 2008. Not supported for 2000, 2023 to 2025.

Barometric pressure TUNDRA_BARO_V2Confirmed

  • Request21 01
  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2016

Example reply from a 2017 Toyota Tundra.

Bits 48 to 55 of the reply, 8 bits.

0x27 = 39 → 39 kPa

Formula
val
Range
0 to 255 kPa
Unit
kPa

Confirmed for 2014, 2017. In testing for 2016.

Calculated engine load LOAD_PCTSAE J1979Confirmed

Represents the amount of work the engine is doing. Expected to reach 100% at wide open throttle/wide open pedal at any altitude, temperature or rpm for both naturally aspirated and boosted engines. If engine load is limited for powertrain protection e.g. engine/turbocharger protection, this value may not reach 100%. For hybrid vehicles, indicates the torque produced only by the internal combustion engine, not the torque being delivered by the entire powertrain. For electric vehicles, the meaning of this parameter is undefined.

Pelican can show this parameter as the engine load.

  • Request01 04
  • Service 01PID 04
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

Confirmed for 2005 to 2008, 2014 to 2015, 2019 to 2021, 2023 to 2024. Supported for 2010 to 2013, 2016 to 2018, 2022, 2025.

Calculated load TUNDRA_LOADConfirmed

Pelican can show this parameter as the engine load.

  • Request21 01
  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1999 to 2004, 2009, 2012 to 2013, 2022 to 2026

Example reply from a 2021 Toyota Tundra.

Bits 0 to 7 of the reply, 8 bits.

0x54 = 84 → (84 × 100 ÷ 255) = 32.941176 %

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

Confirmed for 2005 to 2008, 2010 to 2011, 2015, 2018 to 2021. In testing for 1999, 2001 to 2004, 2009, 2012 to 2013, 2022, 2026. Not supported for 2000, 2023 to 2025.

Calculated load TUNDRA_LOAD_V2Confirmed

Pelican can show this parameter as the engine load.

  • Request21 01
  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2016

Example reply from a 2017 Toyota Tundra.

Bits 0 to 7 of the reply, 8 bits.

0x30 = 48 → (48 × 100 ÷ 255) = 18.823529 %

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

Confirmed for 2014, 2017. In testing for 2016.

Catalyst temperature bank 2 sensor 1 TUNDRA_CAT_T_BANK_2_SENS_1Confirmed

  • Request22 1F 3D
  • Service 22DID 1F3D
  • Module700 → 708
  • Every5 s
  • Testing for 1999 to 2022, 2026

Example reply from a 2025 Toyota Tundra.

Bits 0 to 15 of the reply, 16 bits.

0x0389 = 905 → (905 × 9 ÷ 50 − 40) = 122.9 °F

Formula
(val × 9 ÷ 50 − 40)
Range
-40 to 11756.3 °F
Unit
°F

Confirmed for 2023 to 2025. In testing for 1999 to 2007, 2009 to 2014, 2016 to 2017, 2020 to 2022, 2026. Not supported for 2008, 2015, 2018 to 2019.

Catalyst temperature bank 2 sensor 2 TUNDRA_CAT_T_BANK_2_SENS_2Confirmed

  • Request22 1F 3F
  • Service 22DID 1F3F
  • Module700 → 708
  • Every5 s
  • Testing for 1999 to 2022, 2026

Example reply from a 2025 Toyota Tundra.

Bits 0 to 15 of the reply, 16 bits.

0x02F3 = 755 → (755 × 9 ÷ 50 − 40) = 95.9 °F

Formula
(val × 9 ÷ 50 − 40)
Range
-40 to 11756.3 °F
Unit
°F

Confirmed for 2023 to 2025. In testing for 1999 to 2007, 2009 to 2014, 2016 to 2017, 2020 to 2022, 2026. Not supported for 2008, 2015, 2018 to 2019.

Catalyst temperature, bank 1 sensor 1 TUNDRA_CAT_T_B1S1Confirmed

  • Request21 05
  • Service 21PID 05
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 1999 to 2004, 2009, 2012 to 2013, 2016, 2022 to 2026

Example reply from a 2021 Toyota Tundra.

Bits 16 to 31 of the reply, 16 bits.

0x110A = 4362 → (4362 ÷ 10 − 40) = 396.2 °C

Formula
(val ÷ 10 − 40)
Range
-40 to 6513.5 °C
Unit
°C

Confirmed for 2010 to 2011, 2014 to 2015, 2017 to 2021. In testing for 1999, 2001 to 2004, 2009, 2012 to 2013, 2016, 2022, 2026. Supported for 2005 to 2008. Not supported for 2000, 2023 to 2025.

Catalyst temperature, bank 1 sensor 2 TUNDRA_CAT_T_B1S2Confirmed

  • Request21 05
  • Service 21PID 05
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 1999 to 2004, 2009, 2012 to 2013, 2016, 2022 to 2026

Example reply from a 2021 Toyota Tundra.

Bits 48 to 63 of the reply, 16 bits.

0x0DD0 = 3536 → (3536 ÷ 10 − 40) = 313.6 °C

Formula
(val ÷ 10 − 40)
Range
-40 to 6513.5 °C
Unit
°C

Confirmed for 2010 to 2011, 2014 to 2015, 2017 to 2021. In testing for 1999, 2001 to 2004, 2009, 2012 to 2013, 2016, 2022, 2026. Supported for 2005 to 2008. Not supported for 2000, 2023 to 2025.

Catalyst temperature, bank 1 sensor 2, variant 2 TUNDRA_CAT_T_B1S2_V2

  • Request21 3E
  • Service 21PID 3E
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10 − 40)
Range
-40 to 6513.5 °C
Unit
°C

In testing for 1999 to 2022, 2026. Not supported for 2023 to 2025.

Check mode on TUNDRA_CHECK_MODE_ON

  • Request21 E3
  • Service 21PID E3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 1999 to 2022, 2026. Not supported for 2023 to 2025.

Closed throttle position switch on TUNDRA_CLOSED_THROTTLE_POS_ON

  • Request21 37
  • Service 21PID 37
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bit 125 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 1999 to 2022, 2026. Not supported for 2023 to 2025.

Codes, include history TUNDRA_CODES_INCLUDE

  • Request21 E1
  • Service 21PID E1
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1999 to 2022, 2026. Not supported for 2023 to 2025.

Commanded equivalence ratio EQ_RATSAE J1979Confirmed

Fuel systems that utilize conventional oxygen sensor display the inverse of the commanded open loop equivalence ratio (also known as lambda) while the fuel control system is in open loop. Will indicate 1.000 while in closed-loop fuel.

Pelican can show this parameter as the commanded lambda.

  • Request01 44
  • Service 01PID 44
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 2 ÷ 65535)
Range
0 to 1.99
Unit
Number

Confirmed for 2005 to 2008, 2014 to 2015, 2019 to 2021, 2024 to 2025. Supported for 2022 to 2023.

Continuously variable transmission learning complete TUNDRA_CVT_LEARNED

  • Request21 DD
  • Service 21PID DD
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

In testing for 1999 to 2022, 2026. Not supported for 2023 to 2025.

Continuously variable transmission oil pressure TUNDRA_CVT_OIL_P

  • Request21 BE
  • Service 21PID BE
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 40)
Range
0 to 10200 kPa
Unit
kPa

In testing for 1999 to 2022, 2026. Not supported for 2023 to 2025.

Coolant temperature TUNDRA_COOL_TConfirmed

  • Request22 1F 05
  • Service 22DID 1F05
  • Module7D2 → 7DA
  • Every1 s
  • Testing for 2026

Example reply from a 2025 Toyota Tundra.

Bits 0 to 7 of the reply, 8 bits.

0x31 = 49 → (49 − 40) = 9 °C

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2022 to 2025. In testing for 2026. Not supported for 2000, 2005 to 2008, 2010 to 2012, 2014 to 2015, 2017 to 2021.

Coolant water route switching valve 1, closed? TUNDRA_COOLANT_VALVE_1_CLOSE

  • Request22 28 2C
  • Service 22DID 282C
  • Module700 → 708
  • Every1 s
  • Testing

Bit 15 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

In testing for 1999, 2001 to 2004, 2009, 2012 to 2013, 2016, 2022, 2026. Not supported for 2000, 2005 to 2008, 2010 to 2011, 2014 to 2015, 2017 to 2021, 2023 to 2025.

Coolant water route switching valve 2, closed? TUNDRA_COOLANT_VALVE_2_CLOSE

  • Request22 28 47
  • Service 22DID 2847
  • Module700 → 708
  • Every1 s
  • Testing

Bit 15 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

In testing for 1999, 2001 to 2004, 2009, 2012 to 2013, 2016, 2022, 2026. Not supported for 2000, 2005 to 2008, 2010 to 2011, 2014 to 2015, 2017 to 2021, 2023 to 2025.

Cooling fan duty ratio TUNDRA_COOLING_FAN_DUTY_RATIOConfirmed

  • Request22 10 46
  • Service 22DID 1046
  • Module700 → 708
  • Every1 s
  • Testing for 1999 to 2022, 2026

Example reply from a 2025 Toyota Tundra.

Bits 0 to 7 of the reply, 8 bits.

0x00 = 0 → (0 × 127.5 ÷ 255) = 0 %

Formula
(val × 127.5 ÷ 255)
Range
0 to 127.5 %
Unit
%

Confirmed for 2023 to 2025. In testing for 1999, 2001 to 2004, 2009, 2012 to 2013, 2016, 2022, 2026. Not supported for 2000, 2005 to 2008, 2010 to 2011, 2014 to 2015, 2017 to 2021.

Cruise control on TUNDRA_CRUISE_CTRL_ON

  • Request21 D3
  • Service 21PID D3
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bit 25 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 1999 to 2022, 2026. Not supported for 2023 to 2025.

Cylinder 1 injection volume TUNDRA_CYL_1_INJ_VOLUME

  • Request22 11 31
  • Service 22DID 1131
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 19531 ÷ 1000000 − 640)
Range
-640 to 15
Unit
Raw value

In testing for 1999 to 2007, 2009 to 2014, 2016 to 2017, 2020 to 2022, 2026. Not supported for 2008, 2015, 2018 to 2019, 2023 to 2025.

Cylinder 2 injection volume TUNDRA_CYL_2_INJ_VOLUME

  • Request22 11 31
  • Service 22DID 1131
  • Module700 → 708
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
(val × 19531 ÷ 1000000 − 640)
Range
-640 to 15
Unit
Raw value

In testing for 1999 to 2007, 2009 to 2014, 2016 to 2017, 2020 to 2022, 2026. Not supported for 2008, 2015, 2018 to 2019, 2023 to 2025.

Cylinder 3 injection volume TUNDRA_CYL_3_INJ_VOLUME

  • Request22 11 31
  • Service 22DID 1131
  • Module700 → 708
  • Every1 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
(val × 19531 ÷ 1000000 − 640)
Range
-640 to 15
Unit
Raw value

In testing for 1999 to 2007, 2009 to 2014, 2016 to 2017, 2020 to 2022, 2026. Not supported for 2008, 2015, 2018 to 2019, 2023 to 2025.

Cylinder 4 injection volume TUNDRA_CYL_4_INJ_VOLUME

  • Request22 11 31
  • Service 22DID 1131
  • Module700 → 708
  • Every1 s
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
(val × 19531 ÷ 1000000 − 640)
Range
-640 to 15
Unit
Raw value

In testing for 1999 to 2007, 2009 to 2014, 2016 to 2017, 2020 to 2022, 2026. Not supported for 2008, 2015, 2018 to 2019, 2023 to 2025.

Cylinder number TUNDRA_CYLINDER_NUMBER

  • Request21 C1
  • Service 21PID C1
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 104 to 111 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1999 to 2022, 2026. Not supported for 2023 to 2025.

Destination TUNDRA_DESTINATION

  • Request21 C1
  • Service 21PID C1
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 120 to 127 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1999 to 2022, 2026. Not supported for 2023 to 2025.

Dist battery cable disconnect TUNDRA_DIST_BATT_CABLE

  • Request21 37
  • Service 21PID 37
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 96 to 111 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

In testing for 1999 to 2022, 2026. Not supported for 2023 to 2025.

Electric fan motor on TUNDRA_ELEC_FAN_MOTOR_ON

  • Request21 39
  • Service 21PID 39
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bit 34 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 1999 to 2022, 2026. Not supported for 2023 to 2025.

Electric thermostat duty ratio TUNDRA_ELECTRIC_THERMOSTAT_DUTY_RATIO

  • Request22 28 29
  • Service 22DID 2829
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 1999, 2001 to 2004, 2009, 2012 to 2013, 2016, 2022, 2026. Not supported for 2000, 2005 to 2008, 2010 to 2011, 2014 to 2015, 2017 to 2021, 2023 to 2025.

Electric water pump TUNDRA_ELECTRIC_WATER_PUMP

  • Request22 28 27
  • Service 22DID 2827
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 40)
Range
0 to 10200 rpm
Unit
rpm

In testing for 1999, 2001 to 2004, 2009, 2012 to 2013, 2016, 2022, 2026. Not supported for 2000, 2005 to 2008, 2010 to 2011, 2014 to 2015, 2017 to 2021, 2023 to 2025.

Electric water pump RPM TUNDRA_EWP_RPM

  • Request22 10 43
  • Service 22DID 1043
  • Module700 → 708
  • Every250 ms
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
(val × 25)
Range
0 to 6375 rpm
Unit
rpm

In testing for 1999, 2001 to 2004, 2009, 2013, 2016, 2026. Not supported for 2000, 2005 to 2008, 2010 to 2012, 2014 to 2015, 2017 to 2025.

Electric water pump target speed TUNDRA_EWP_TARGET_VSS

  • Request22 10 43
  • Service 22DID 1043
  • Module700 → 708
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 25)
Range
0 to 6375 rpm
Unit
rpm

In testing for 1999, 2001 to 2004, 2009, 2013, 2016, 2026. Not supported for 2000, 2005 to 2008, 2010 to 2012, 2014 to 2015, 2017 to 2025.

Engine coolant temperature ECTSAE J1979Confirmed

Your engine temperature must operate within a certain temperature range to operate efficiently and safely. If it runs too hot, then your engine could be permanently damaged. If it runs too cold, then your engine will use more fuel than necessary.

Pelican can show this parameter as the engine coolant temperature.

  • Request01 05
  • Service 01PID 05
  • Module7E0 → 7E8
  • Every500 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2006 to 2008, 2014 to 2015, 2019, 2021. Supported for 2005, 2010 to 2013, 2016 to 2018, 2020, 2022 to 2025.

Engine coolant temperature TUNDRA_ECTConfirmed

Pelican can show this parameter as the engine coolant temperature.

  • Request21 26
  • Service 21PID 26
  • Module7C4 → 7CC
  • Every5 s
  • Testing for 1999 to 2006, 2009, 2012 to 2013, 2016, 2022 to 2026

Example reply from a 2021 Toyota Tundra.

Bits 0 to 7 of the reply, 8 bits.

0x93 = 147 → (147 × 89.25 ÷ 255 + 1.3) = 52.75 °C

Formula
(val × 89.25 ÷ 255 + 1.3)
Range
1.3 to 90.55 °C
Unit
°C

Confirmed for 2007 to 2008, 2010 to 2011, 2014 to 2015, 2017 to 2021. In testing for 1999, 2001 to 2004, 2009, 2012 to 2013, 2016, 2022, 2026. Not supported for 2000, 2005 to 2006, 2023 to 2025.

Engine coolant temperature TUNDRA_ECT_7C0Confirmed

Pelican can show this parameter as the engine coolant temperature.

  • Request21 23
  • Service 21PID 23
  • Module7C0 → 7C8
  • Every5 s
  • Testing for 1999 to 2006, 2009, 2012 to 2013, 2016, 2022 to 2026

Example reply from a 2021 Toyota Tundra.

Bits 0 to 7 of the reply, 8 bits.

0x6E = 110 → (110 ÷ 2) = 55 °C

Formula
(val ÷ 2)
Range
0 to 127.5 °C
Unit
°C

Confirmed for 2007 to 2008, 2010 to 2011, 2014 to 2015, 2017 to 2021. In testing for 1999, 2001 to 2004, 2009, 2012 to 2013, 2016, 2022, 2026. Not supported for 2000, 2005 to 2006, 2023 to 2025.

Engine coolant temperature TUNDRA_ECT_7E0Confirmed

Pelican can show this parameter as the engine coolant temperature.

  • Request21 01
  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1999 to 2004, 2009, 2012 to 2013, 2022 to 2026

Example reply from a 2021 Toyota Tundra.

Bits 64 to 71 of the reply, 8 bits.

0x6A = 106 → (106 − 40) = 66 °C

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2010 to 2011, 2015, 2018 to 2021. In testing for 1999, 2001 to 2004, 2009, 2012 to 2013, 2022, 2026. Supported for 2005 to 2008. Not supported for 2000, 2023 to 2025.

Engine coolant temperature TUNDRA_ECT_7E0_V2Confirmed

Pelican can show this parameter as the engine coolant temperature.

  • Request21 01
  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2016

Example reply from a 2017 Toyota Tundra.

Bits 56 to 63 of the reply, 8 bits.

0x82 = 130 → (130 − 40) = 90 °C

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2014, 2017. In testing for 2016.

Engine coolant temperature, at ignition TUNDRA_ECT_IGNConfirmed

  • Request22 10 41
  • Service 22DID 1041
  • Module700 → 708
  • Every5 s
  • Testing for 1999 to 2022, 2026

Example reply from a 2025 Toyota Tundra.

Bits 0 to 7 of the reply, 8 bits.

0x26 = 38 → (38 × 62.5 ÷ 100 − 40) = -16.25 °C

Formula
(val × 62.5 ÷ 100 − 40)
Range
-40 to 119.375 °C
Unit
°C

Confirmed for 2023 to 2025. In testing for 1999, 2001 to 2004, 2009, 2012 to 2013, 2016, 2022, 2026. Not supported for 2000, 2005 to 2008, 2010 to 2011, 2014 to 2015, 2017 to 2021.

Engine coolant temperature, initial TUNDRA_ECT_INITConfirmed

  • Request22 10 41
  • Service 22DID 1041
  • Module700 → 708
  • Every5 s
  • Testing for 1999 to 2022, 2026

Example reply from a 2025 Toyota Tundra.

Bits 8 to 15 of the reply, 8 bits.

0x26 = 38 → (38 × 62.5 ÷ 100 − 40) = -16.25 °C

Formula
(val × 62.5 ÷ 100 − 40)
Range
-40 to 119.375 °C
Unit
°C

Confirmed for 2023 to 2025. In testing for 1999, 2001 to 2004, 2009, 2012 to 2013, 2016, 2022, 2026. Not supported for 2000, 2005 to 2008, 2010 to 2011, 2014 to 2015, 2017 to 2021.

Engine independent TUNDRA_ENG_INDEPENDENT

  • Request21 49
  • Service 21PID 49
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bit 91 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 1999 to 2022, 2026. Not supported for 2023 to 2025.

Engine independent control TUNDRA_ENG_INDEPENDENT_CTRL

  • Request21 49
  • Service 21PID 49
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bit 88 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 1999 to 2022, 2026. Not supported for 2023 to 2025.

Engine oil pressure TUNDRA_EOPConfirmed

  • Request22 10 74
  • Service 22DID 1074
  • Module700 → 708
  • Every1 s
  • Testing for 1999 to 2021, 2026

Example reply from a 2025 Toyota Tundra.

Bits 0 to 15 of the reply, 16 bits.

0x0000 = 0 → (0 × 10 ÷ 128) = 0 kPa

Formula
(val × 10 ÷ 128)
Range
0 to 5119.92 kPa
Unit
kPa

Confirmed for 2022 to 2025. In testing for 1999, 2001 to 2004, 2009, 2013, 2026. Not supported for 2000, 2005 to 2008, 2010 to 2012, 2014 to 2021.

Engine oil pressure control valve TUNDRA_EOP_CONTROL_VALVE

  • Request22 28 48
  • Service 22DID 2848
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 0.0762939)
Range
0 to 4999.9207 mA
Unit
mA

In testing for 1999, 2001 to 2004, 2009, 2013, 2016, 2026. Not supported for 2000, 2005 to 2008, 2010 to 2012, 2014 to 2015, 2017 to 2025.

Engine oil temperature TUNDRA_EOTConfirmed

Pelican can show this parameter as the engine oil temperature.

  • Request21 51
  • Service 21PID 51
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1999 to 2009, 2011, 2013, 2022 to 2026

Example reply from a 2021 Toyota Tundra.

Bits 72 to 79 of the reply, 8 bits.

0x6E = 110 → (110 − 40) = 70 °C

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2010, 2012, 2014 to 2021. In testing for 1999, 2001 to 2004, 2009, 2013, 2026. Not supported for 2000, 2005 to 2008, 2011, 2022 to 2025.

Engine oil temperature TUNDRA_EOT_700Confirmed

Pelican can show this parameter as the engine oil temperature.

  • Request22 10 7B
  • Service 22DID 107B
  • Module700 → 708
  • Every5 s
  • Testing for 1999 to 2021, 2026

Example reply from a 2025 Toyota Tundra.

Bits 192 to 199 of the reply, 8 bits.

0x48 = 72 → (72 − 40) = 32 °C

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2022 to 2025. In testing for 1999, 2001 to 2004, 2009, 2013, 2016, 2026. Not supported for 2000, 2005 to 2008, 2010 to 2012, 2014 to 2015, 2017 to 2021.

Engine oil temperature, variation 2 TUNDRA_EOT_V2Confirmed

Pelican can show this parameter as the engine oil temperature.

  • Request22 1F 5C
  • Service 22DID 1F5C
  • Module700 → 708
  • Every5 s
  • Testing for 1999 to 2021, 2026

Example reply from a 2025 Toyota Tundra.

Bits 0 to 7 of the reply, 8 bits.

0x2D = 45 → (45 − 40) = 5 °C

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2022 to 2025. In testing for 1999, 2001 to 2004, 2009, 2013, 2016, 2026. Not supported for 2000, 2005 to 2008, 2010 to 2012, 2014 to 2015, 2017 to 2021.

Engine run time TUNDRA_ENGINE_RUN_TIMEConfirmed

  • Request21 01
  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1999 to 2004, 2009, 2012 to 2013, 2022 to 2026

Example reply from a 2021 Toyota Tundra.

Bits 96 to 111 of the reply, 16 bits.

0x03C9 = 969 → 969 s

Formula
val
Range
0 to 65535 s
Unit
s

Confirmed for 2010 to 2011, 2015, 2018 to 2021. In testing for 1999, 2001 to 2004, 2009, 2012 to 2013, 2022, 2026. Supported for 2005 to 2008. Not supported for 2000, 2023 to 2025.

Engine run time TUNDRA_ENGINE_RUN_TIME_V2Confirmed

  • Request21 01
  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2016

Example reply from a 2017 Toyota Tundra.

Bits 88 to 103 of the reply, 16 bits.

0x4113 = 16659 → 16,659 s

Formula
val
Range
0 to 65535 s
Unit
s

Confirmed for 2014, 2017. In testing for 2016.

Engine run time, up to 255 sec. only TUNDRA_ENG_RUN_TIME_UP_255

  • Request21 49
  • Service 21PID 49
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
val
Range
0 to 255 s
Unit
s

In testing for 1999 to 2022, 2026. Not supported for 2023 to 2025.

Engine stall control FB flow TUNDRA_ENG_STALL_CTRL_FB

  • Request21 52
  • Service 21PID 52
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
(val × 5 ÷ 4096 − 40)
Range
-40 to 39.99
Unit
Number

In testing for 1999 to 2022, 2026. Not supported for 2023 to 2025.

Evaporative purge duty TUNDRA_EVAP_PURGE_DUTY_7E0

  • Request21 2E
  • Service 21PID 2E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 20 ÷ 51)
Range
0 to 100 %
Unit
%

In testing for 1999 to 2022, 2026. Not supported for 2023 to 2025.

Evaporative purge flow TUNDRA_EVAP_PURGE_FLOW

  • Request21 37
  • Service 21PID 37
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
(val × 25 ÷ 4096)
Range
0 to 399.99 %
Unit
%

In testing for 1999 to 2022, 2026. Not supported for 2023 to 2025.

Evaporative purge vacuum switching valve on TUNDRA_EVAP_PURGE_VSV_ON

  • Request21 39
  • Service 21PID 39
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bit 11 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 1999 to 2022, 2026. Not supported for 2023 to 2025.

Exhaust gas recirculation step position TUNDRA_EGR_STEP_POSITIONConfirmed

  • Request21 47
  • Service 21PID 47
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1999 to 2018, 2020 to 2026

Example reply from a 2019 Toyota Tundra.

Bits 0 to 7 of the reply, 8 bits.

0x00 = 0 → 0

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2019. In testing for 1999 to 2018, 2020 to 2022, 2026. Not supported for 2023 to 2025.

Exhaust gas recirculation temperature TUNDRA_EGR_T

  • Request21 ED
  • Service 21PID ED
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 53 ÷ 85)
Range
0 to 159 °C
Unit
°C

In testing for 1999 to 2022, 2026. Not supported for 2023 to 2025.

Exhaust gas recirculation valve step TUNDRA_EGR_STEP

  • Request21 E7
  • Service 21PID E7
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1999 to 2022, 2026. Not supported for 2023 to 2025.

Exhaust VVT change angle, bank 1 TUNDRA_EXHAUST_VVT_ANGLE_B1Confirmed

  • Request22 10 88
  • Service 22DID 1088
  • Module700 → 708
  • Every1 s
  • Testing for 1999 to 2022, 2026

Example reply from a 2025 Toyota Tundra.

Bits 0 to 15 of the reply, 16 bits.

0x0000 = 0 → (0 × 639.9 ÷ 65535) = 0 °

Formula
(val × 639.9 ÷ 65535)
Range
0 to 639.9 °
Unit
°

Confirmed for 2023 to 2025. In testing for 1999, 2001 to 2004, 2009, 2012 to 2013, 2016, 2022, 2026. Not supported for 2000, 2005 to 2008, 2010 to 2011, 2014 to 2015, 2017 to 2021.

Exhaust VVT hold learn value, bank 1 TUNDRA_EXHAUST_VVT_HOLD_LEARN_B1Confirmed

  • Request22 10 89
  • Service 22DID 1089
  • Module700 → 708
  • Every3600 s
  • Testing for 1999 to 2022, 2026

Example reply from a 2025 Toyota Tundra.

Bits 0 to 15 of the reply, 16 bits.

0x1E7A = 7802 → (7802 × 399.9 ÷ 65535) = 47.60845 %

Formula
(val × 399.9 ÷ 65535)
Range
0 to 399.9 %
Unit
%

Confirmed for 2023 to 2025. In testing for 1999, 2001 to 2004, 2009, 2012 to 2013, 2016, 2022, 2026. Not supported for 2000, 2005 to 2008, 2010 to 2011, 2014 to 2015, 2017 to 2021.

Exhaust VVT oil control valve control duty TUNDRA_EXHAUST_VVT_OCV_CONTROL_DUTYConfirmed

  • Request22 10 62
  • Service 22DID 1062
  • Module700 → 708
  • Every1 s
  • Testing for 1999 to 2021, 2026

Example reply from a 2025 Toyota Tundra.

Bits 0 to 15 of the reply, 16 bits.

0x0000 = 0 → (0 × 400 ÷ 65535) = 0 %

Formula
(val × 400 ÷ 65535)
Range
0 to 400 %
Unit
%

Confirmed for 2022 to 2025. In testing for 1999, 2001 to 2004, 2009, 2013, 2016, 2026. Not supported for 2000, 2005 to 2008, 2010 to 2012, 2014 to 2015, 2017 to 2021.

Exhaust VVT target angle B1 TUNDRA_EXHAUST_VVT_TARGET_ANGLE_B1Confirmed

  • Request22 10 71
  • Service 22DID 1071
  • Module700 → 708
  • Every1 s
  • Testing for 1999 to 2021, 2026

Example reply from a 2025 Toyota Tundra.

Bits 0 to 15 of the reply, 16 bits.

0x0000 = 0 → (0 × 639.9 ÷ 65535) = 0 °

Formula
(val × 639.9 ÷ 65535)
Range
0 to 639.9 °
Unit
°

Confirmed for 2022 to 2025. In testing for 1999, 2001 to 2004, 2009, 2013, 2016, 2026. Not supported for 2000, 2005 to 2008, 2010 to 2012, 2014 to 2015, 2017 to 2021.

Exhaust VVT timing most over-advanced learn value, bank 1 TUNDRA_EXHAUST_VVT_OVER_ADV_LEARN_B1Confirmed

  • Request22 10 8F
  • Service 22DID 108F
  • Module700 → 708
  • Every3600 s
  • Testing for 1999 to 2022, 2026

Example reply from a 2025 Toyota Tundra.

Bits 0 to 15 of the reply, 16 bits.

0x2F50 = 12112 → (12112 × 639.99 ÷ 65535) = 118.281207 °

Formula
(val × 639.99 ÷ 65535)
Range
0 to 639.99 °
Unit
°

Confirmed for 2023 to 2025. In testing for 1999, 2001 to 2004, 2009, 2012 to 2013, 2016, 2022, 2026. Not supported for 2000, 2005 to 2008, 2010 to 2011, 2014 to 2015, 2017 to 2021.

Front/rear motor torque ratio TUNDRA_FRONT_REAR_MOTOR_TQConfirmed

  • Request22 10 39
  • Service 22DID 1039
  • Module7D2 → 7DA
  • Every250 ms
  • Testing for 1999 to 2022, 2024, 2026

Example reply from a 2025 Toyota Tundra.

Bits 16 to 31 of the reply, 16 bits.

0x0ACE = 2766 → (2766 ÷ 1000 − 32.768) = -30.002

Formula
(val ÷ 1000 − 32.768)
Range
-32.76 to 32.76
Unit
Number

Confirmed for 2023, 2025. In testing for 2022, 2026. Not supported for 2024.

Fuel cut for engine stop request TUNDRA_F_C_ENG_STOP_REQ

  • Request21 49
  • Service 21PID 49
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bit 92 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 1999 to 2022, 2026. Not supported for 2023 to 2025.

Fuel cut TAU on TUNDRA_FC_TAU_ON

  • Request21 37
  • Service 21PID 37
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bit 127 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 1999 to 2022, 2026. Not supported for 2023 to 2025.

Fuel filter temperature TUNDRA_FFT

  • Request22 10 9A
  • Service 22DID 109A
  • Module700 → 708
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 1999, 2001 to 2004, 2009, 2012 to 2013, 2016, 2022, 2026. Not supported for 2000, 2005 to 2008, 2010 to 2011, 2014 to 2015, 2017 to 2021, 2023 to 2025.

G sensor calibration, complete TUNDRA_G_SENS_CALIBRATION

  • Request21 83
  • Service 21PID 83
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 1999 to 2022, 2026. Not supported for 2023 to 2025.

G sensor learning value TUNDRA_G_SENS_LEARNING

  • Request21 83
  • Service 21PID 83
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 8 to 23 of the reply, 16 bits.

Formula
(val × 5 ÷ 4096)
Range
0 to 79.998 V
Unit
V

In testing for 1999 to 2022, 2026. Not supported for 2023 to 2025.

Generator inverter temperature TUNDRA_GEN_INVERTER_T

  • Request22 10 A4
  • Service 22DID 10A4
  • Module7D2 → 7DA
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2022, 2026. Not supported for 2023 to 2025.

Generator inverter temperature TUNDRA_GEN_INVERTER_T_7D2

  • Request22 10 A8
  • Service 22DID 10A8
  • Module7D2 → 7DA
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2022, 2026. Not supported for 2023 to 2025.

Generator inverter temperature after ignition on TUNDRA_GEN_INVERTER_T_AFTER_ON

  • Request22 10 A8
  • Service 22DID 10A8
  • Module7D2 → 7DA
  • Every5 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2022, 2026. Not supported for 2023 to 2025.

Glass humidity TUNDRA_GLASS_HUMIDITY

  • Request21 B1
  • Service 21PID B1
  • Module7C4 → 7CC
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 20 ÷ 13107)
Range
0 to 100 %
Unit
%

In testing for 1999 to 2022, 2026. Not supported for 2023 to 2025.

Glass temperature TUNDRA_GLASS_T

  • Request21 AF
  • Service 21PID AF
  • Module7C4 → 7CC
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 9 ÷ 500 − 557.8)
Range
-557 to 621 °F
Unit
°F

In testing for 1999 to 2022, 2026. Not supported for 2023 to 2025.

Hydraulic valve, communication open TUNDRA_HV_COMM_OPEN

  • Request21 BE
  • Service 21PID BE
  • Module7B0 → 7B8
  • Every1 s
  • Testing for 1999 to 2017, 2022 to 2026

Bit 17 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

In testing for 1999, 2001 to 2004, 2009, 2012 to 2013, 2016, 2022, 2026. Supported for 2018 to 2021. Not supported for 2000, 2005 to 2008, 2010 to 2011, 2014 to 2015, 2017, 2023 to 2025.

Idle control TUNDRA_IDLE_CTRL

  • Request21 E6
  • Service 21PID E6
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 1999 to 2022, 2026. Not supported for 2023 to 2025.

Idle spark advance control 1 TUNDRA_IDLE_SPARK_ADVN_CTRL_1

  • Request21 52
  • Service 21PID 52
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 16)
Range
0 to 15.93 °
Unit
°

In testing for 1999 to 2022, 2026. Not supported for 2023 to 2025.

Idle spark advance control 2 TUNDRA_IDLE_SPARK_ADVN_CTRL_2

  • Request21 52
  • Service 21PID 52
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
(val ÷ 16)
Range
0 to 15.93 °
Unit
°

In testing for 1999 to 2022, 2026. Not supported for 2023 to 2025.

Idle spark advance control 3 TUNDRA_IDLE_SPARK_ADVN_CTRL_3

  • Request21 52
  • Service 21PID 52
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
(val ÷ 16)
Range
0 to 15.93 °
Unit
°

In testing for 1999 to 2022, 2026. Not supported for 2023 to 2025.

Idle spark advance control 4 TUNDRA_IDLE_SPARK_ADVN_CTRL_4

  • Request21 52
  • Service 21PID 52
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
(val ÷ 16)
Range
0 to 15.93 °
Unit
°

In testing for 1999 to 2022, 2026. Not supported for 2023 to 2025.

Idle spark advance control, cylinder 1 TUNDRA_IDLE_SAC_CYL_1

  • Request22 10 78
  • Service 22DID 1078
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 6.25 ÷ 100)
Range
0 to 15.9375 °
Unit
°

In testing for 1999, 2001 to 2004, 2009, 2013, 2016, 2026. Not supported for 2000, 2005 to 2008, 2010 to 2012, 2014 to 2015, 2017 to 2025.

Idle spark advance control, cylinder 2 TUNDRA_IDLE_SAC_CYL_2

  • Request22 10 78
  • Service 22DID 1078
  • Module700 → 708
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
(val × 6.25 ÷ 100)
Range
0 to 15.9375 °
Unit
°

In testing for 1999, 2001 to 2004, 2009, 2013, 2016, 2026. Not supported for 2000, 2005 to 2008, 2010 to 2012, 2014 to 2015, 2017 to 2025.

Idle spark advance control, cylinder 3 TUNDRA_IDLE_SAC_CYL_3

  • Request22 10 78
  • Service 22DID 1078
  • Module700 → 708
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
(val × 6.25 ÷ 100)
Range
0 to 15.9375 °
Unit
°

In testing for 1999, 2001 to 2004, 2009, 2013, 2016, 2026. Not supported for 2000, 2005 to 2008, 2010 to 2012, 2014 to 2015, 2017 to 2025.

Idle spark advance control, cylinder 4 TUNDRA_IDLE_SAC_CYL_4

  • Request22 10 78
  • Service 22DID 1078
  • Module700 → 708
  • Every1 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
(val × 6.25 ÷ 100)
Range
0 to 15.9375 °
Unit
°

In testing for 1999, 2001 to 2004, 2009, 2013, 2016, 2026. Not supported for 2000, 2005 to 2008, 2010 to 2012, 2014 to 2015, 2017 to 2025.

Idle speed control learning TUNDRA_IDLE_SPD_CTRL

  • Request21 49
  • Service 21PID 49
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bit 93 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 1999 to 2022, 2026. Not supported for 2023 to 2025.

Idle speed control learning value, l/s TUNDRA_IDLE_SPD_CTRL_L_S

  • Request21 49
  • Service 21PID 49
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 72 to 87 of the reply, 16 bits.

Formula
(val × 0.0012206912)
Range
0 to 79.99
Unit
Number

In testing for 1999 to 2022, 2026. Not supported for 2023 to 2025.

IG OFF elapsed time TUNDRA_IG_OFF_ELAPSED_TIME

  • Request21 37
  • Service 21PID 37
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 80 to 95 of the reply, 16 bits.

Formula
(val × 10)
Range
0 to 655350 min
Unit
min

In testing for 1999 to 2022, 2026. Not supported for 2023 to 2025.

Ignition advance TUNDRA_SPARKADV_21

  • Request21 0E
  • Service 21PID 0E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 2 − 64)
Range
-64 to 63.5 °
Unit
°

In testing for 1999 to 2022, 2026. Not supported for 2023 to 2025.

Ignition timing advance TUNDRA_IGN_ADVANCEConfirmed

  • Request21 03
  • Service 21PID 03
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1999 to 2004, 2009, 2012 to 2013, 2016 to 2017, 2021 to 2026

Example reply from a 2020 Toyota Tundra.

Bits 48 to 55 of the reply, 8 bits.

0x97 = 151 → (151 ÷ 2 − 64) = 11.5 °

Formula
(val ÷ 2 − 64)
Range
-64 to 63.5 °
Unit
°

Confirmed for 2010 to 2011, 2014 to 2015, 2018 to 2020. In testing for 1999, 2001 to 2004, 2009, 2012 to 2013, 2016, 2022, 2026. Supported for 2005 to 2008. Not supported for 2000, 2017, 2021, 2023 to 2025.

Immobilizer communication on TUNDRA_IMMOBILIZER_ON

  • Request21 37
  • Service 21PID 37
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bit 120 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 1999 to 2022, 2026. Not supported for 2023 to 2025.

Initial engine coolant temperature TUNDRA_INITIAL_ECT

  • Request21 37
  • Service 21PID 37
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 531 ÷ 850 − 40)
Range
-40 to 119.3
Unit
Number

In testing for 1999 to 2022, 2026. Not supported for 2023 to 2025.

Initial intake air temperature TUNDRA_INITIAL_IAT

  • Request21 37
  • Service 21PID 37
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
(val × 5 ÷ 8 − 40)
Range
-40 to 119 °C
Unit
°C

In testing for 1999 to 2022, 2026. Not supported for 2023 to 2025.

Injection TUNDRA_INJECTIONConfirmed

  • Request22 10 19
  • Service 22DID 1019
  • Module700 → 708
  • Every1 s
  • Testing for 1999 to 2022, 2026

Example reply from a 2025 Toyota Tundra.

Bits 0 to 7 of the reply, 8 bits.

0x01 = 1 → DIRECT

Unit
Named states
States
Raw valueStateMeaning
1DIRECTDirect
2BOTHBoth

Confirmed for 2023 to 2025. In testing for 1999, 2001 to 2004, 2009, 2012 to 2013, 2016, 2022, 2026. Not supported for 2000, 2005 to 2008, 2010 to 2011, 2014 to 2015, 2017 to 2021.

Injection duration for cylinder 1 TUNDRA_INJ_DUR_CYL_1Confirmed

  • Request21 3C
  • Service 21PID 3C
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1999 to 2017, 2019 to 2026

Example reply from a 2018 Toyota Tundra.

Bits 16 to 31 of the reply, 16 bits.

0x0978 = 2424 → (2424 ÷ 1000) = 2.424 ms

Formula
(val ÷ 1000)
Range
0 to 65.535 ms
Unit
ms

Confirmed for 2018. In testing for 1999 to 2017, 2019 to 2022, 2026. Not supported for 2023 to 2025.

Injection feedback value 1 TUNDRA_INJ_FEEDBACK_1

  • Request22 11 2B
  • Service 22DID 112B
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 5 ÷ 32 − 20)
Range
-20 to 15
Unit
Raw value

In testing for 1999 to 2007, 2009 to 2014, 2016 to 2017, 2020 to 2022, 2026. Not supported for 2008, 2015, 2018 to 2019, 2023 to 2025.

Injection feedback value 1 TUNDRA_INJ_FEEDBACK_1_700

  • Request22 11 B8
  • Service 22DID 11B8
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 332 ÷ 2125 − 19.99811765)
Range
-19.9981 to 19.8418
Unit
Raw value

In testing for 1999 to 2007, 2009 to 2014, 2016 to 2017, 2020 to 2022, 2026. Not supported for 2008, 2015, 2018 to 2019, 2023 to 2025.

Injection feedback value 2 TUNDRA_INJ_FEEDBACK_2

  • Request22 11 2B
  • Service 22DID 112B
  • Module700 → 708
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
(val × 5 ÷ 32 − 20)
Range
-20 to 15
Unit
Raw value

In testing for 1999 to 2007, 2009 to 2014, 2016 to 2017, 2020 to 2022, 2026. Not supported for 2008, 2015, 2018 to 2019, 2023 to 2025.

Injection feedback value 2 TUNDRA_INJ_FEEDBACK_2_700

  • Request22 11 B8
  • Service 22DID 11B8
  • Module700 → 708
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
(val × 332 ÷ 2125 − 19.99811765)
Range
-19.9981 to 19.8418
Unit
Raw value

In testing for 1999 to 2007, 2009 to 2014, 2016 to 2017, 2020 to 2022, 2026. Not supported for 2008, 2015, 2018 to 2019, 2023 to 2025.

Injection feedback value 3 TUNDRA_INJ_FEEDBACK_3

  • Request22 11 2B
  • Service 22DID 112B
  • Module700 → 708
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
(val × 5 ÷ 32 − 20)
Range
-20 to 15
Unit
Raw value

In testing for 1999 to 2007, 2009 to 2014, 2016 to 2017, 2020 to 2022, 2026. Not supported for 2008, 2015, 2018 to 2019, 2023 to 2025.

Injection feedback value 3 TUNDRA_INJ_FEEDBACK_3_700

  • Request22 11 B8
  • Service 22DID 11B8
  • Module700 → 708
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
(val × 332 ÷ 2125 − 19.99811765)
Range
-19.9981 to 19.8418
Unit
Raw value

In testing for 1999 to 2007, 2009 to 2014, 2016 to 2017, 2020 to 2022, 2026. Not supported for 2008, 2015, 2018 to 2019, 2023 to 2025.

Injection feedback value 4 TUNDRA_INJ_FEEDBACK_4

  • Request22 11 2B
  • Service 22DID 112B
  • Module700 → 708
  • Every1 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
(val × 5 ÷ 32 − 20)
Range
-20 to 15
Unit
Raw value

In testing for 1999 to 2007, 2009 to 2014, 2016 to 2017, 2020 to 2022, 2026. Not supported for 2008, 2015, 2018 to 2019, 2023 to 2025.

Injection feedback value 4 TUNDRA_INJ_FEEDBACK_4_700

  • Request22 11 B8
  • Service 22DID 11B8
  • Module700 → 708
  • Every1 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
(val × 332 ÷ 2125 − 19.99811765)
Range
-19.9981 to 19.8418
Unit
Raw value

In testing for 1999 to 2007, 2009 to 2014, 2016 to 2017, 2020 to 2022, 2026. Not supported for 2008, 2015, 2018 to 2019, 2023 to 2025.

Injection feedback value 5 TUNDRA_INJ_FEEDBACK_5

  • Request22 11 B8
  • Service 22DID 11B8
  • Module700 → 708
  • Every1 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
(val × 332 ÷ 2125 − 19.99811765)
Range
-19.9981 to 19.8418
Unit
Raw value

In testing for 1999 to 2007, 2009 to 2014, 2016 to 2017, 2020 to 2022, 2026. Not supported for 2008, 2015, 2018 to 2019, 2023 to 2025.

Injection feedback value 6 TUNDRA_INJ_FEEDBACK_6

  • Request22 11 B8
  • Service 22DID 11B8
  • Module700 → 708
  • Every1 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
(val × 332 ÷ 2125 − 19.99811765)
Range
-19.9981 to 19.8418
Unit
Raw value

In testing for 1999 to 2007, 2009 to 2014, 2016 to 2017, 2020 to 2022, 2026. Not supported for 2008, 2015, 2018 to 2019, 2023 to 2025.

Injection volume TUNDRA_INJ_VOLConfirmed

  • Request22 10 17
  • Service 22DID 1017
  • Module700 → 708
  • Every1 s
  • Testing for 1999 to 2021, 2026

Example reply from a 2025 Toyota Tundra.

Bits 0 to 15 of the reply, 16 bits.

0x0000 = 0 → (0 ÷ 3200) = 0 L

Formula
(val ÷ 3200)
Range
0 to 20 L
Unit
L

Confirmed for 2022 to 2025. In testing for 1999, 2001 to 2004, 2009, 2013, 2016, 2026. Not supported for 2000, 2005 to 2008, 2010 to 2012, 2014 to 2015, 2017 to 2021.

Injection volume - target TUNDRA_INJ_VOLUME_TGT

  • Request22 11 2C
  • Service 22DID 112C
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 19531 ÷ 1000000)
Range
0 to 15
Unit
Raw value

In testing for 1999 to 2007, 2009 to 2014, 2016 to 2017, 2020 to 2022, 2026. Not supported for 2008, 2015, 2018 to 2019, 2023 to 2025.

Injection volume 1 TUNDRA_INJ_VOLUME_1

  • Request22 11 8B
  • Service 22DID 118B
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 19531 ÷ 1000000 − 640)
Range
-40 to 300
Unit
Raw value

In testing for 1999 to 2007, 2009 to 2014, 2016 to 2017, 2020 to 2022, 2026. Not supported for 2008, 2015, 2018 to 2019, 2023 to 2025.

Injection volume 2 TUNDRA_INJ_VOLUME_2

  • Request22 11 8B
  • Service 22DID 118B
  • Module700 → 708
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
(val × 19531 ÷ 1000000 − 640)
Range
-40 to 300
Unit
Raw value

In testing for 1999 to 2007, 2009 to 2014, 2016 to 2017, 2020 to 2022, 2026. Not supported for 2008, 2015, 2018 to 2019, 2023 to 2025.

Injection volume 3 TUNDRA_INJ_VOLUME_3

  • Request22 11 8B
  • Service 22DID 118B
  • Module700 → 708
  • Every1 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
(val × 19531 ÷ 1000000 − 640)
Range
-40 to 300
Unit
Raw value

In testing for 1999 to 2007, 2009 to 2014, 2016 to 2017, 2020 to 2022, 2026. Not supported for 2008, 2015, 2018 to 2019, 2023 to 2025.

Injection volume 5 TUNDRA_INJ_VOLUME_5

  • Request22 11 8B
  • Service 22DID 118B
  • Module700 → 708
  • Every1 s
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
(val × 19531 ÷ 1000000 − 640)
Range
-40 to 300
Unit
Raw value

In testing for 1999 to 2007, 2009 to 2014, 2016 to 2017, 2020 to 2022, 2026. Not supported for 2008, 2015, 2018 to 2019, 2023 to 2025.

Injection volume 6 TUNDRA_INJ_VOLUME_6

  • Request22 11 8B
  • Service 22DID 118B
  • Module700 → 708
  • Every1 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
(val × 19531 ÷ 1000000 − 640)
Range
-40 to 300
Unit
Raw value

In testing for 1999 to 2007, 2009 to 2014, 2016 to 2017, 2020 to 2022, 2026. Not supported for 2008, 2015, 2018 to 2019, 2023 to 2025.

Injection volume per 10 injections, cylinder 1 TUNDRA_INJ_VOL_CYL_1Confirmed

  • Request21 3C
  • Service 21PID 3C
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1999 to 2017, 2019 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 32000000)
Range
0 to 0.002 L
Unit
L

Confirmed for 2018. In testing for 1999 to 2017, 2019 to 2022, 2026. Not supported for 2023 to 2025.

Injection volume total TUNDRA_INJ_VOLUME_TOT

  • Request22 11 2F
  • Service 22DID 112F
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 19531 ÷ 1000000 − 640)
Range
-640 to 15
Unit
Raw value

In testing for 1999 to 2007, 2009 to 2014, 2016 to 2017, 2020 to 2022, 2026. Not supported for 2008, 2015, 2018 to 2019, 2023 to 2025.

Injector port TUNDRA_INJECTOR_PORTConfirmed

  • Request22 10 18
  • Service 22DID 1018
  • Module700 → 708
  • Every1 s
  • Testing for 1999 to 2022, 2026

Example reply from a 2025 Toyota Tundra.

Bits 0 to 15 of the reply, 16 bits.

0x0000 = 0 → (0 ÷ 1000) = 0 ms

Formula
(val ÷ 1000)
Range
0 to 65.535 ms
Unit
ms

Confirmed for 2023 to 2025. In testing for 1999, 2001 to 2004, 2009, 2012 to 2013, 2016, 2022, 2026. Not supported for 2000, 2005 to 2008, 2010 to 2011, 2014 to 2015, 2017 to 2021.

Injector pulse width TUNDRA_INJ_PW

  • Request21 E4
  • Service 21PID E4
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 163 ÷ 1275)
Range
0 to 32.6 ms
Unit
ms

In testing for 1999 to 2022, 2026. Not supported for 2023 to 2025.

Injector pulse width TUNDRA_INJ_WIDTH

  • Request21 F3
  • Service 21PID F3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
(val × 16 ÷ 125)
Range
0 to 32.64 ms
Unit
ms

In testing for 1999 to 2022, 2026. Not supported for 2023 to 2025.

Input shaft speed TUNDRA_SPD_NIN

  • Request21 81
  • Service 21PID 81
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
(val × 50)
Range
0 to 12750 rpm
Unit
rpm

In testing for 1999 to 2022, 2026. Not supported for 2023 to 2025.

Intake air temperature TUNDRA_IATConfirmed

  • Request21 01
  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1999 to 2004, 2009, 2012 to 2013, 2022 to 2026

Example reply from a 2021 Toyota Tundra.

Bits 48 to 55 of the reply, 8 bits.

0x32 = 50 → (50 − 40) = 10 °C

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2010 to 2011, 2015, 2018 to 2021. In testing for 1999, 2001 to 2004, 2009, 2012 to 2013, 2022, 2026. Supported for 2005 to 2008. Not supported for 2000, 2023 to 2025.

Intake air temperature TUNDRA_IAT_21

  • Request21 0F
  • Service 21PID 0F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 1999 to 2022, 2026. Not supported for 2023 to 2025.

Intake air temperature, bank 1 sensor 1 TUNDRA_IAT_B1S1Confirmed

  • Request22 1F 77
  • Service 22DID 1F77
  • Module700 → 708
  • Every5 s
  • Testing for 1999 to 2022, 2026

Example reply from a 2025 Toyota Tundra.

Bits 8 to 15 of the reply, 8 bits.

0x2E = 46 → (46 − 40) = 6 °C

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2023 to 2025. In testing for 1999 to 2007, 2009 to 2014, 2016 to 2017, 2020 to 2022, 2026. Not supported for 2008, 2015, 2018 to 2019.

Intake air temperature, bank 1 sensor 2 TUNDRA_IAT_B1S2Confirmed

  • Request22 1F 77
  • Service 22DID 1F77
  • Module700 → 708
  • Every5 s
  • Testing for 1999 to 2022, 2026

Example reply from a 2025 Toyota Tundra.

Bits 16 to 23 of the reply, 8 bits.

0x00 = 0 → (0 − 40) = -40 °C

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2023 to 2025. In testing for 1999 to 2007, 2009 to 2014, 2016 to 2017, 2020 to 2022, 2026. Not supported for 2008, 2015, 2018 to 2019.

Intake VVT change angle, bank 1 TUNDRA_INTAKE_VVT_CHANGE_ANGLE_BANK_1Confirmed

  • Request22 10 87
  • Service 22DID 1087
  • Module700 → 708
  • Every1 s
  • Testing for 1999 to 2021, 2026

Example reply from a 2025 Toyota Tundra.

Bits 0 to 15 of the reply, 16 bits.

0x0000 = 0 → (0 × 639.9 ÷ 65535) = 0 °

Formula
(val × 639.9 ÷ 65535)
Range
0 to 639.9 °
Unit
°

Confirmed for 2022 to 2025. In testing for 1999, 2001 to 2004, 2009, 2013, 2016, 2026. Not supported for 2000, 2005 to 2008, 2010 to 2012, 2014 to 2015, 2017 to 2021.

Intake VVT most over-retarded learn value, bank 1 TUNDRA_INTAKE_VVT_OVER_RET_LEARN_B1Confirmed

  • Request22 10 8D
  • Service 22DID 108D
  • Module700 → 708
  • Every3600 s
  • Testing for 1999 to 2022, 2026

Example reply from a 2025 Toyota Tundra.

Bits 0 to 15 of the reply, 16 bits.

0x0C1D = 3101 → (3101 × 639.99 ÷ 65535) = 30.283192 °

Formula
(val × 639.99 ÷ 65535)
Range
0 to 639.99 °
Unit
°

Confirmed for 2023 to 2025. In testing for 1999, 2001 to 2004, 2009, 2012 to 2013, 2016, 2022, 2026. Not supported for 2000, 2005 to 2008, 2010 to 2011, 2014 to 2015, 2017 to 2021.

Intake VVT target angle B1 TUNDRA_INTAKE_VVT_TARGET_ANGLE_B1Confirmed

  • Request22 10 6F
  • Service 22DID 106F
  • Module700 → 708
  • Every1 s
  • Testing for 1999 to 2021, 2026

Example reply from a 2025 Toyota Tundra.

Bits 0 to 15 of the reply, 16 bits.

0x0000 = 0 → (0 × 639.9 ÷ 65535) = 0 °

Formula
(val × 639.9 ÷ 65535)
Range
0 to 639.9 °
Unit
°

Confirmed for 2022 to 2025. In testing for 1999, 2001 to 2004, 2009, 2013, 2016, 2026. Not supported for 2000, 2005 to 2008, 2010 to 2012, 2014 to 2015, 2017 to 2021.

Integrated engine run time TUNDRA_INTEGRATED_ENG_RUNConfirmed

  • Request22 15 E8
  • Service 22DID 15E8
  • Module700 → 708
  • Every3600 s
  • Testing for 1999 to 2022, 2026

Example reply from a 2025 Toyota Tundra.

Bits 80 to 95 of the reply, 16 bits.

0x000A = 10 → 10 h

Formula
val
Range
0 to 65535 h
Unit
h

Confirmed for 2023 to 2025. In testing for 1999 to 2007, 2009 to 2014, 2016 to 2017, 2020 to 2022, 2026. Not supported for 2008, 2015, 2018 to 2019.

Intercooler coolant temperature TUNDRA_INTERCOOLER_ECT

  • Request22 11 9C
  • Service 22DID 119C
  • Module700 → 708
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 1999 to 2007, 2009 to 2014, 2016 to 2017, 2020 to 2022, 2026. Not supported for 2008, 2015, 2018 to 2019, 2023 to 2025.

Intercooler water pump TUNDRA_INTERCOOLER_WATERConfirmed

  • Request22 28 20
  • Service 22DID 2820
  • Module700 → 708
  • Every1 s
  • Testing for 1999 to 2022, 2026

Example reply from a 2025 Toyota Tundra.

Bits 0 to 15 of the reply, 16 bits.

0x0000 = 0 → (0 × 80 ÷ 13107) = 0 %

Formula
(val × 80 ÷ 13107)
Range
0 to 300 %
Unit
%

Confirmed for 2023 to 2025. In testing for 1999 to 2007, 2009 to 2014, 2016 to 2017, 2020 to 2022, 2026. Not supported for 2008, 2015, 2018 to 2019.

Internal temperature TUNDRA_ECU_INTERNAL_TConfirmed

  • Request22 10 5E
  • Service 22DID 105E
  • Module700 → 708
  • Every5 s
  • Testing for 1999 to 2021, 2026

Example reply from a 2025 Toyota Tundra.

Bits 0 to 7 of the reply, 8 bits.

0x19 = 25 → (25 − 40) = -15 °C

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2022 to 2025. In testing for 1999, 2001 to 2004, 2009, 2013, 2016, 2026. Not supported for 2000, 2005 to 2008, 2010 to 2012, 2014 to 2015, 2017 to 2021.

Inverter coolant temperature TUNDRA_INVRT_COOLANT_TConfirmed

  • Request22 10 B2
  • Service 22DID 10B2
  • Module7D2 → 7DA
  • Every1 s
  • Testing for 2026

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
0 to 100 °C
Unit
°C

Confirmed for 2022 to 2025. In testing for 2026. Not supported for 2000, 2005 to 2008, 2010 to 2012, 2014 to 2015, 2017 to 2021.

Inverter water pump duty TUNDRA_INVERTER_WATER_PMP

  • Request22 11 12
  • Service 22DID 1112
  • Module7D2 → 7DA
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 15259 ÷ 5000000)
Range
0 to 199 %
Unit
%

In testing for 2022, 2026. Not supported for 2023 to 2025.

Judge time engine ignition TUNDRA_JUDGE_TIME_ENG_IGN

  • Request21 49
  • Service 21PID 49
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 56 to 63 of the reply, 8 bits.

Formula
(val ÷ 10)
Range
0 to 25.5 s
Unit
s

In testing for 1999 to 2022, 2026. Not supported for 2023 to 2025.

Judge time engine output TUNDRA_JUDGE_TIME_ENG

  • Request21 49
  • Service 21PID 49
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 64 to 71 of the reply, 8 bits.

Formula
(val ÷ 10)
Range
0 to 25.5 s
Unit
s

In testing for 1999 to 2022, 2026. Not supported for 2023 to 2025.

Key cycle TUNDRA_KEY_CYCLEConfirmed

  • Request22 01 02
  • Service 22DID 0102
  • Module7D2 → 7DA
  • Every1 s
  • Testing for 1999 to 2022, 2024, 2026

Example reply from a 2025 Toyota Tundra.

Bits 0 to 15 of the reply, 16 bits.

0x0D08 = 3336 → 3,336

Formula
val
Range
0 to 65535
Unit
Number

Confirmed for 2023, 2025. In testing for 2022, 2026. Not supported for 2024.

Knock adjust TUNDRA_KNOCK_ADJUST

  • Request21 B2
  • Service 21PID B2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 2048 ÷ 65535 − 64)
Range
-64 to 1984 °
Unit
°

In testing for 1999 to 2022, 2026. Not supported for 2023 to 2025.

Knock adjust TUNDRA_KNOCK_ADJUST_7E0

  • Request21 37
  • Service 21PID 37
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
(val × 2048 ÷ 65535 − 1024)
Range
-1024 to 1024 °
Unit
°

In testing for 1999 to 2022, 2026. Not supported for 2023 to 2025.

Knock correct learn value TUNDRA_KNOCK_CORRECT_LEARN

  • Request21 37
  • Service 21PID 37
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
(val ÷ 32 − 1024)
Range
-1024 to 1023 °
Unit
°

In testing for 1999 to 2022, 2026. Not supported for 2023 to 2025.

Knock correction, learned value TUNDRA_KNOCK_CORRECT_LEARNED_VALUEConfirmed

  • Request22 10 5C
  • Service 22DID 105C
  • Module700 → 708
  • Every1 s
  • Testing for 1999 to 2021, 2026

Example reply from a 2025 Toyota Tundra.

Bits 0 to 15 of the reply, 16 bits.

0x819F = 33183 → (33183 × 312.5 ÷ 10000 − 1024) = 12.96875

Formula
(val × 312.5 ÷ 10000 − 1024)
Range
-1024 to 1023
Unit
Number

Confirmed for 2022 to 2025. In testing for 1999, 2001 to 2004, 2009, 2013, 2016, 2026. Not supported for 2000, 2005 to 2008, 2010 to 2012, 2014 to 2015, 2017 to 2021.

Knock feedback TUNDRA_KNOCK_FEEDBACK

  • Request21 B2
  • Service 21PID B2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
(val × 2048 ÷ 65535 − 64)
Range
-64 to 1984 °
Unit
°

In testing for 1999 to 2022, 2026. Not supported for 2023 to 2025.

Knock feedback TUNDRA_KNOCK_FEEDBACK_7E0

  • Request21 37
  • Service 21PID 37
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
(val × 2048 ÷ 65535 − 1024)
Range
-1024 to 1024 °
Unit
°

In testing for 1999 to 2022, 2026. Not supported for 2023 to 2025.

Knock feedback value TUNDRA_KNOCK_FEEDBACK_VALUEConfirmed

  • Request22 10 5C
  • Service 22DID 105C
  • Module700 → 708
  • Every1 s
  • Testing for 1999 to 2021, 2026

Example reply from a 2025 Toyota Tundra.

Bits 16 to 31 of the reply, 16 bits.

0x7FA0 = 32672 → (32672 × 312.5 ÷ 10000 − 1024) = -3

Formula
(val × 312.5 ÷ 10000 − 1024)
Range
-1024 to 1023
Unit
Number

Confirmed for 2022 to 2025. In testing for 1999, 2001 to 2004, 2009, 2013, 2016, 2026. Not supported for 2000, 2005 to 2008, 2010 to 2012, 2014 to 2015, 2017 to 2021.

Lock up state TUNDRA_LOCK_UP_STATEConfirmed

  • Request22 16 20
  • Service 22DID 1620
  • Module701 → 709
  • Every1 s
  • Testing for 1999 to 2022, 2026

Example reply from a 2025 Toyota Tundra.

Bit 7 of the reply.

0b0 = 0 → 0

Formula
val
Range
0 to 1
Unit
Off or on

Confirmed for 2023 to 2025. In testing for 1999, 2001 to 2004, 2009, 2012 to 2013, 2016, 2022, 2026. Not supported for 2000, 2005 to 2008, 2010 to 2011, 2014 to 2015, 2017 to 2021.

Long term fuel trim, bank 1 TUNDRA_LONG_FT_B1Confirmed

  • Request21 03
  • Service 21PID 03
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1999 to 2004, 2009, 2012 to 2013, 2016 to 2017, 2021 to 2026

Example reply from a 2020 Toyota Tundra.

Bits 24 to 31 of the reply, 8 bits.

0x85 = 133 → (133 × 200 ÷ 256 − 100) = 3.90625 %

Formula
(val × 200 ÷ 256 − 100)
Range
-100 to 99.21 %
Unit
%

Confirmed for 2010 to 2011, 2014 to 2015, 2018 to 2020. In testing for 1999, 2001 to 2004, 2009, 2012 to 2013, 2016, 2022, 2026. Supported for 2005 to 2008. Not supported for 2000, 2017, 2021, 2023 to 2025.

Long term fuel trim, bank 2 TUNDRA_LONG_FT_B2Confirmed

  • Request21 03
  • Service 21PID 03
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1999 to 2004, 2009, 2012 to 2013, 2016 to 2017, 2021 to 2026

Example reply from a 2020 Toyota Tundra.

Bits 40 to 47 of the reply, 8 bits.

0x81 = 129 → (129 × 200 ÷ 256 − 100) = 0.78125 %

Formula
(val × 200 ÷ 256 − 100)
Range
-100 to 99.21 %
Unit
%

Confirmed for 2010 to 2011, 2014 to 2015, 2018 to 2020. In testing for 1999, 2001 to 2004, 2009, 2012 to 2013, 2016, 2022, 2026. Supported for 2005 to 2008. Not supported for 2000, 2017, 2021, 2023 to 2025.

Long-term fuel trim, bank 1 TUNDRA_LTFT1_21

  • Request21 07
  • Service 21PID 07
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 0.7809803922 − 100)
Range
-100 to 99.15 %
Unit
%

In testing for 1999 to 2022, 2026. Not supported for 2023 to 2025.

Manifold absolute pressure TUNDRA_MAP_7E0Confirmed

  • Request21 01
  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1999 to 2004, 2009, 2012 to 2013, 2022 to 2026

Example reply from a 2021 Toyota Tundra.

Bits 40 to 47 of the reply, 8 bits.

0x32 = 50 → 50 kPa

Formula
val
Range
0 to 255 kPa
Unit
kPa

Confirmed for 2010 to 2011, 2015, 2018 to 2021. In testing for 1999, 2001 to 2004, 2009, 2012 to 2013, 2022, 2026. Supported for 2005 to 2008. Not supported for 2000, 2023 to 2025.

Manifold absolute pressure TUNDRA_MAP_7E0_V2Confirmed

  • Request21 01
  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2016

Example reply from a 2017 Toyota Tundra.

Bits 40 to 47 of the reply, 8 bits.

0x42 = 66 → 66 kPa

Formula
val
Range
0 to 255 kPa
Unit
kPa

Confirmed for 2014, 2017. In testing for 2016.

Mass air flow TUNDRA_MAFConfirmed

Pelican can show this parameter as the mass air flow.

  • Request21 01
  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1999 to 2004, 2009, 2012 to 2013, 2022 to 2026

Example reply from a 2021 Toyota Tundra.

Bits 24 to 39 of the reply, 16 bits.

0x0243 = 579 → (579 ÷ 100) = 5.79 g/s

Formula
(val ÷ 100)
Range
0 to 655.35 g/s
Unit
g/s

Confirmed for 2010 to 2011, 2015, 2018 to 2021. In testing for 1999, 2001 to 2004, 2009, 2012 to 2013, 2022, 2026. Supported for 2005 to 2008. Not supported for 2000, 2023 to 2025.

Mass air flow TUNDRA_MAF_21

  • Request21 10
  • Service 21PID 10
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 655 g/s
Unit
g/s

In testing for 1999 to 2022, 2026. Not supported for 2023 to 2025.

Mass air flow TUNDRA_MAF_V2Confirmed

Pelican can show this parameter as the mass air flow.

  • Request21 01
  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2016

Example reply from a 2017 Toyota Tundra.

Bits 24 to 39 of the reply, 16 bits.

0x0230 = 560 → (560 ÷ 100) = 5.6 g/s

Formula
(val ÷ 100)
Range
0 to 655.35 g/s
Unit
g/s

Confirmed for 2014, 2017. In testing for 2016.

Master cylinder open TUNDRA_MASTER_CYLINDER_OPENConfirmed

  • Request21 BE
  • Service 21PID BE
  • Module7B0 → 7B8
  • Every1 s
  • Testing for 1999 to 2017, 2022 to 2026

Example reply from a 2021 Toyota Tundra.

Bit 8 of the reply.

0b0 = 0 → 0

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2018 to 2021. In testing for 1999, 2001 to 2004, 2009, 2012 to 2013, 2016, 2022, 2026. Not supported for 2000, 2005 to 2008, 2010 to 2011, 2014 to 2015, 2017, 2023 to 2025.

Master cylinder sensor temperature TUNDRA_MASTER_CYL_TEMPConfirmed

  • Request22 10 06
  • Service 22DID 1006
  • Module7B0 → 7B8
  • Every5 s
  • Testing for 1999 to 2021, 2026

Example reply from a 2025 Toyota Tundra.

Bits 0 to 7 of the reply, 8 bits.

0x51 = 81 → (81 − 80) = 1 °C

Formula
(val − 80)
Range
-20 to 100 °C
Unit
°C

Confirmed for 2022 to 2025. In testing for 1999, 2001 to 2004, 2009, 2013, 2026. Not supported for 2000, 2005 to 2008, 2010 to 2012, 2014 to 2021.

Maximum generator inverter temperature TUNDRA_MAX_GEN_INVERTER_T

  • Request22 10 A8
  • Service 22DID 10A8
  • Module7D2 → 7DA
  • Every5 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2022, 2026. Not supported for 2023 to 2025.

Maximum motor inverter temperature TUNDRA_MAX_MOTOR_INVERTER_TConfirmed

  • Request22 10 A5
  • Service 22DID 10A5
  • Module7D2 → 7DA
  • Every5 s
  • Testing for 1999 to 2022, 2024, 2026

Example reply from a 2025 Toyota Tundra.

Bits 16 to 23 of the reply, 8 bits.

0x6E = 110 → (110 − 40) = 70 °C

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2023, 2025. In testing for 2022, 2026. Not supported for 2024.

Misfire count, all cylinders TUNDRA_MISFIRE_CNTConfirmed

  • Request22 10 A5
  • Service 22DID 10A5
  • Module700 → 708
  • Every1 s
  • Testing for 1999 to 2021, 2026

Example reply from a 2025 Toyota Tundra.

Bits 0 to 7 of the reply, 8 bits.

0x00 = 0 → 0

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2022 to 2025. In testing for 1999, 2001 to 2004, 2009, 2013, 2016, 2026. Not supported for 2000, 2005 to 2008, 2010 to 2012, 2014 to 2015, 2017 to 2021.

Misfire count, cylinder 1 TUNDRA_MISFIRE_CYL1

  • Request22 10 A7
  • Service 22DID 10A7
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1999, 2001 to 2004, 2009, 2013, 2016, 2026. Not supported for 2000, 2005 to 2008, 2010 to 2012, 2014 to 2015, 2017 to 2025.

Misfire count, cylinder 2 TUNDRA_MISFIRE_CYL2

  • Request22 10 A7
  • Service 22DID 10A7
  • Module700 → 708
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1999, 2001 to 2004, 2009, 2013, 2016, 2026. Not supported for 2000, 2005 to 2008, 2010 to 2012, 2014 to 2015, 2017 to 2025.

Misfire count, cylinder 3 TUNDRA_MISFIRE_CYL3

  • Request22 10 A7
  • Service 22DID 10A7
  • Module700 → 708
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1999, 2001 to 2004, 2009, 2013, 2016, 2026. Not supported for 2000, 2005 to 2008, 2010 to 2012, 2014 to 2015, 2017 to 2025.

Misfire count, cylinder 4 TUNDRA_MISFIRE_CYL4

  • Request22 10 A7
  • Service 22DID 10A7
  • Module700 → 708
  • Every1 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1999, 2001 to 2004, 2009, 2013, 2016, 2026. Not supported for 2000, 2005 to 2008, 2010 to 2012, 2014 to 2015, 2017 to 2025.

Misfire load TUNDRA_MISFIRE_LOADConfirmed

  • Request22 10 AA
  • Service 22DID 10AA
  • Module700 → 708
  • Every1 s
  • Testing for 1999 to 2021, 2026

Example reply from a 2025 Toyota Tundra.

Bits 0 to 7 of the reply, 8 bits.

0x00 = 0 → (0 × 510 ÷ 255) = 0 %

Formula
(val × 510 ÷ 255)
Range
0 to 510 %
Unit
%

Confirmed for 2022 to 2025. In testing for 1999, 2001 to 2004, 2009, 2013, 2016, 2026. Not supported for 2000, 2005 to 2008, 2010 to 2012, 2014 to 2015, 2017 to 2021.

Misfire margin TUNDRA_MISFIRE_MARGIN

  • Request22 10 AA
  • Service 22DID 10AA
  • Module700 → 708
  • Every1 s
  • Testing for 1999 to 2021, 2026

Bits 32 to 39 of the reply, 8 bits.

Formula
(val − 128)
Range
-128 to 127 rpm
Unit
rpm

In testing for 1999, 2001 to 2004, 2009, 2013, 2016, 2026. Supported for 2022 to 2025. Not supported for 2000, 2005 to 2008, 2010 to 2012, 2014 to 2015, 2017 to 2021.

Misfire RPM TUNDRA_MISFIRE_RPM

  • Request22 10 AA
  • Service 22DID 10AA
  • Module700 → 708
  • Every1 s
  • Testing for 1999 to 2021, 2026

Bits 24 to 31 of the reply, 8 bits.

Formula
(val × 6375 ÷ 255)
Range
0 to 6375 rpm
Unit
rpm

In testing for 1999, 2001 to 2004, 2009, 2013, 2016, 2026. Supported for 2022 to 2025. Not supported for 2000, 2005 to 2008, 2010 to 2012, 2014 to 2015, 2017 to 2021.

Misfire RPM TUNDRA_MISFIRE_RPM_7E0Confirmed

  • Request21 45
  • Service 21PID 45
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1999 to 2004, 2009, 2012 to 2013, 2016, 2022 to 2026

Example reply from a 2021 Toyota Tundra.

Bits 8 to 15 of the reply, 8 bits.

0x00 = 0 → (0 × 25) = 0 rpm

Formula
(val × 25)
Range
0 to 6375 rpm
Unit
rpm

Confirmed for 2010 to 2011, 2014 to 2015, 2017 to 2021. In testing for 1999, 2001 to 2004, 2009, 2012 to 2013, 2016, 2022, 2026. Supported for 2005 to 2008. Not supported for 2000, 2023 to 2025.

Misfire test result, incomplete TUNDRA_MIS_TEST_RESULT

  • Request21 E3
  • Service 21PID E3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 1999 to 2022, 2026. Not supported for 2023 to 2025.

Model year TUNDRA_MODEL_YEAR

  • Request21 C1
  • Service 21PID C1
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 128 to 135 of the reply, 8 bits.

Formula
(val + 1900)
Range
1900 to 2155
Unit
Number

In testing for 1999 to 2022, 2026. Not supported for 2023 to 2025.

Motor inverter temperature TUNDRA_MOTOR_INVERTER_TConfirmed

  • Request22 10 A5
  • Service 22DID 10A5
  • Module7D2 → 7DA
  • Every5 s
  • Testing for 1999 to 2022, 2024, 2026

Example reply from a 2025 Toyota Tundra.

Bits 0 to 7 of the reply, 8 bits.

0x51 = 81 → (81 − 40) = 41 °C

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2023, 2025. In testing for 2022, 2026. Not supported for 2024.

Motor inverter temperature after ignition on TUNDRA_MOTOR_INVERTER_T_ONConfirmed

  • Request22 10 A5
  • Service 22DID 10A5
  • Module7D2 → 7DA
  • Every5 s
  • Testing for 1999 to 2022, 2024, 2026

Example reply from a 2025 Toyota Tundra.

Bits 8 to 15 of the reply, 8 bits.

0x50 = 80 → (80 − 40) = 40 °C

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2023, 2025. In testing for 2022, 2026. Not supported for 2024.

Motor inverter, maximum temperature TUNDRA_M_INVRT_MAX_T

  • Request22 10 A6
  • Service 22DID 10A6
  • Module7D2 → 7DA
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2026. Not supported for 2000, 2005 to 2008, 2010 to 2012, 2014 to 2015, 2017 to 2025.

Motor regenerative break torque TUNDRA_MOTOR_REGENERATIVE_BREAKConfirmed

  • Request22 10 69
  • Service 22DID 1069
  • Module7D2 → 7DA
  • Every250 ms
  • Testing for 1999 to 2022, 2024, 2026

Example reply from a 2025 Toyota Tundra.

Bits 16 to 31 of the reply, 16 bits.

0x8000 = 32768 → (32768 ÷ 8 − 4096) = 0 kW

Formula
(val ÷ 8 − 4096)
Range
-4096 to 4095 kW
Unit
kW

Confirmed for 2023, 2025. In testing for 2022, 2026. Not supported for 2024.

Motor regenerative break torque, requested TUNDRA_MOTOR_REGENERATIVEConfirmed

  • Request22 10 69
  • Service 22DID 1069
  • Module7D2 → 7DA
  • Every250 ms
  • Testing for 1999 to 2022, 2024, 2026

Example reply from a 2025 Toyota Tundra.

Bits 0 to 15 of the reply, 16 bits.

0x8000 = 32768 → (32768 ÷ 8 − 4096) = 0 kW

Formula
(val ÷ 8 − 4096)
Range
-4096 to 4095 kW
Unit
kW

Confirmed for 2023, 2025. In testing for 2022, 2026. Not supported for 2024.

Motor RPM TUNDRA_RPM_7D2Confirmed

  • Request22 10 A1
  • Service 22DID 10A1
  • Module7D2 → 7DA
  • Every250 ms
  • Testing for 2026

Example reply from a 2025 Toyota Tundra.

Bits 0 to 15 of the reply, 16 bits.

0x7FFF = 32767 → (32767 − 32768) = -1 rpm

Formula
(val − 32768)
Range
-32768 to 32767 rpm
Unit
rpm

Confirmed for 2022 to 2025. In testing for 2026. Not supported for 2000, 2005 to 2008, 2010 to 2012, 2014 to 2015, 2017 to 2021.

Motor torque TUNDRA_TQConfirmed

  • Request22 10 A1
  • Service 22DID 10A1
  • Module7D2 → 7DA
  • Every250 ms
  • Testing for 2026

Example reply from a 2025 Toyota Tundra.

Bits 48 to 63 of the reply, 16 bits.

0x7FFA = 32762 → (32762 ÷ 8 − 4096) = -0.75 N·m

Formula
(val ÷ 8 − 4096)
Range
-4096 to 4095 N·m
Unit
N·m

Confirmed for 2022 to 2025. In testing for 2026. Not supported for 2000, 2005 to 2008, 2010 to 2012, 2014 to 2015, 2017 to 2021.

O2 heater b1s2_active TUNDRA_O2_HEATER_B1S2

  • Request21 3A
  • Service 21PID 3A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 68 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 1999 to 2022, 2026. Not supported for 2023 to 2025.

O2 heater current val bank 1 sensor 2 TUNDRA_O2_HEATER_CURR_VAL

  • Request21 3A
  • Service 21PID 3A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
(val ÷ 13107)
Range
0 to 4.999 A
Unit
A

In testing for 1999 to 2022, 2026. Not supported for 2023 to 2025.

Open side malfunction on TUNDRA_OPEN_SIDE_ONConfirmed

  • Request21 41
  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing for 1999 to 2017, 2020 to 2026

Example reply from a 2019 Toyota Tundra.

Bit 145 of the reply.

0b0 = 0 → 0

Formula
val
Range
0 to 1
Unit
Number

Confirmed for 2018 to 2019. In testing for 1999 to 2017, 2020 to 2022, 2026. Not supported for 2023 to 2025.

Output shaft speed TUNDRA_SPD_NOUT

  • Request21 81
  • Service 21PID 81
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
(val × 50)
Range
0 to 12750 rpm
Unit
rpm

In testing for 1999 to 2022, 2026. Not supported for 2023 to 2025.

OXS1, A/FS2 test result, incomplete TUNDRA_OXS1_FS2_TEST_RESULT

  • Request21 E3
  • Service 21PID E3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 1999 to 2022, 2026. Not supported for 2023 to 2025.

Oxygen sensor voltage, bank 1 sensor 1 TUNDRA_O2S11_V

  • Request21 14
  • Service 21PID 14
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 0.0049960784)
Range
0 to 1.27 V
Unit
V

In testing for 1999 to 2022, 2026. Not supported for 2023 to 2025.

Oxygen sensor voltage, bank 1 sensor 2 TUNDRA_O2S_B1S2Confirmed

  • Request21 04
  • Service 21PID 04
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1999 to 2004, 2009, 2012 to 2013, 2016, 2022 to 2026

Example reply from a 2021 Toyota Tundra.

Bits 144 to 151 of the reply, 8 bits.

0x9C = 156 → (156 × 5 ÷ 1000) = 0.78 V

Formula
(val × 5 ÷ 1000)
Range
0 to 1.275 V
Unit
V

Confirmed for 2010 to 2011, 2014 to 2015, 2017 to 2021. In testing for 1999, 2001 to 2004, 2009, 2012 to 2013, 2016, 2022, 2026. Supported for 2005 to 2008. Not supported for 2000, 2023 to 2025.

PM accumulation ratio - bank 1 TUNDRA_PM_ACCUMULATION_RAT_1

  • Request22 11 05
  • Service 22DID 1105
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 2)
Range
0 to 15 %
Unit
%

In testing for 1999 to 2007, 2009 to 2014, 2016 to 2017, 2020 to 2022, 2026. Not supported for 2008, 2015, 2018 to 2019, 2023 to 2025.

Purge cut vacuum switching valve duty TUNDRA_PURGE_CUT_VSV_DUTY

  • Request21 3A
  • Service 21PID 3A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
(val × 25 ÷ 4096)
Range
0 to 399.9 %
Unit
%

In testing for 1999 to 2022, 2026. Not supported for 2023 to 2025.

Racing operation TUNDRA_RACING_OPERATION

  • Request21 49
  • Service 21PID 49
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bit 90 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 1999 to 2022, 2026. Not supported for 2023 to 2025.

Real engine torque TUNDRA_REAL_ENG_TQ

  • Request22 10 09
  • Service 22DID 1009
  • Module7B1 → 7B9
  • Every250 ms
  • Testing

Bits 32 to 47 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 32)
Range
-20 to 150 N·m
Unit
N·m

In testing for 1999 to 2007, 2009 to 2014, 2016 to 2017, 2020 to 2022, 2026. Not supported for 2008, 2015, 2018 to 2019, 2023 to 2025.

Rear motor inverter, coolant temperature TUNDRA_RM_INVRT_COOL_T

  • Request22 10 A6
  • Service 22DID 10A6
  • Module7D2 → 7DA
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2026. Not supported for 2000, 2005 to 2008, 2010 to 2012, 2014 to 2015, 2017 to 2025.

Rear motor regenerative break torque TUNDRA_REAR_MOTOR_REGENERATIVE

  • Request22 10 6A
  • Service 22DID 106A
  • Module7D2 → 7DA
  • Every250 ms
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
(val ÷ 8 − 4096)
Range
-4096 to 4095 kW
Unit
kW

In testing for 2022, 2026. Not supported for 2023 to 2025.

Rear motor regenerative break torque, requested TUNDRA_REAR_MOTOR

  • Request22 10 6A
  • Service 22DID 106A
  • Module7D2 → 7DA
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 8 − 4096)
Range
-4096 to 4095 kW
Unit
kW

In testing for 2022, 2026. Not supported for 2023 to 2025.

Rear motor speed TUNDRA_RM_TQ_REQ

  • Request22 10 A2
  • Service 22DID 10A2
  • Module7D2 → 7DA
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val − 32768)
Range
-32768 to 32767 rpm
Unit
rpm

In testing for 2026. Not supported for 2000, 2005 to 2008, 2010 to 2012, 2014 to 2015, 2017 to 2025.

Rear motor torque TUNDRA_RM_TQ

  • Request22 10 A2
  • Service 22DID 10A2
  • Module7D2 → 7DA
  • Every250 ms
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
(val ÷ 8 − 4096)
Range
-4096 to 4095 N·m
Unit
N·m

In testing for 2026. Not supported for 2000, 2005 to 2008, 2010 to 2012, 2014 to 2015, 2017 to 2025.

Regulator pressure TUNDRA_REGULATOR_P

  • Request21 53
  • Service 21PID 53
  • Module7C4 → 7CC
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 375105 ÷ 25500 − 456.68)
Range
-456.68 to 3294 kPa
Unit
kPa

In testing for 1999, 2001 to 2004, 2009, 2012 to 2013, 2016, 2022, 2026. Not supported for 2000, 2005 to 2008, 2010 to 2011, 2014 to 2015, 2017 to 2021, 2023 to 2025.

Request engine run time TUNDRA_REQ_ENG_RUN_TIME

  • Request21 49
  • Service 21PID 49
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 48 to 55 of the reply, 8 bits.

Formula
(val ÷ 10)
Range
0 to 25.5 s
Unit
s

In testing for 1999 to 2022, 2026. Not supported for 2023 to 2025.

Request warm-up TUNDRA_REQ_WARM_UP

  • Request21 49
  • Service 21PID 49
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bit 89 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 1999 to 2022, 2026. Not supported for 2023 to 2025.

Requested engine torque TUNDRA_REQ_ENG_TQ

  • Request21 49
  • Service 21PID 49
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 4)
Range
0 to 16383
Unit
Number

In testing for 1999 to 2022, 2026. Not supported for 2023 to 2025.

Rough idle, cylinder 1 TUNDRA_ROUGH_IDLE_CYL_1Confirmed

  • Request22 10 84
  • Service 22DID 1084
  • Module700 → 708
  • Every1 s
  • Testing for 1999 to 2022, 2026

Example reply from a 2025 Toyota Tundra.

Bits 0 to 7 of the reply, 8 bits.

0x01 = 1 → 1 °

Formula
val
Range
0 to 255 °
Unit
°

Confirmed for 2023 to 2025. In testing for 1999, 2001 to 2004, 2009, 2012 to 2013, 2016, 2022, 2026. Not supported for 2000, 2005 to 2008, 2010 to 2011, 2014 to 2015, 2017 to 2021.

Rough idle, cylinder 2 TUNDRA_ROUGH_IDLE_CYL_2Confirmed

  • Request22 10 84
  • Service 22DID 1084
  • Module700 → 708
  • Every1 s
  • Testing for 1999 to 2022, 2026

Example reply from a 2025 Toyota Tundra.

Bits 8 to 15 of the reply, 8 bits.

0x00 = 0 → 0 °

Formula
val
Range
0 to 255 °
Unit
°

Confirmed for 2023 to 2025. In testing for 1999, 2001 to 2004, 2009, 2012 to 2013, 2016, 2022, 2026. Not supported for 2000, 2005 to 2008, 2010 to 2011, 2014 to 2015, 2017 to 2021.

Rough idle, cylinder 3 TUNDRA_ROUGH_IDLE_CYL_3Confirmed

  • Request22 10 84
  • Service 22DID 1084
  • Module700 → 708
  • Every1 s
  • Testing for 1999 to 2022, 2026

Example reply from a 2025 Toyota Tundra.

Bits 16 to 23 of the reply, 8 bits.

0x3F = 63 → 63 °

Formula
val
Range
0 to 255 °
Unit
°

Confirmed for 2023 to 2025. In testing for 1999, 2001 to 2004, 2009, 2012 to 2013, 2016, 2022, 2026. Not supported for 2000, 2005 to 2008, 2010 to 2011, 2014 to 2015, 2017 to 2021.

Rough idle, cylinder 4 TUNDRA_ROUGH_IDLE_CYL_4Confirmed

  • Request22 10 84
  • Service 22DID 1084
  • Module700 → 708
  • Every1 s
  • Testing for 1999 to 2022, 2026

Example reply from a 2025 Toyota Tundra.

Bits 24 to 31 of the reply, 8 bits.

0x00 = 0 → 0 °

Formula
val
Range
0 to 255 °
Unit
°

Confirmed for 2023 to 2025. In testing for 1999, 2001 to 2004, 2009, 2012 to 2013, 2016, 2022, 2026. Not supported for 2000, 2005 to 2008, 2010 to 2011, 2014 to 2015, 2017 to 2021.

Short term fuel trim, bank 1 TUNDRA_SHORT_FT_B1Confirmed

Pelican can show this parameter as the short term fuel trim.

  • Request21 03
  • Service 21PID 03
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1999 to 2004, 2009, 2012 to 2013, 2016 to 2017, 2021 to 2026

Example reply from a 2020 Toyota Tundra.

Bits 16 to 23 of the reply, 8 bits.

0x7A = 122 → (122 × 200 ÷ 256 − 100) = -4.6875 %

Formula
(val × 200 ÷ 256 − 100)
Range
-100 to 99.21 %
Unit
%

Confirmed for 2010 to 2011, 2014 to 2015, 2018 to 2020. In testing for 1999, 2001 to 2004, 2009, 2012 to 2013, 2016, 2022, 2026. Supported for 2005 to 2008. Not supported for 2000, 2017, 2021, 2023 to 2025.

Short term fuel trim, bank 2 TUNDRA_SHORT_FT_B2Confirmed

Pelican can show this parameter as the short term fuel trim.

  • Request21 03
  • Service 21PID 03
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1999 to 2004, 2009, 2012 to 2013, 2016 to 2017, 2021 to 2026

Example reply from a 2020 Toyota Tundra.

Bits 32 to 39 of the reply, 8 bits.

0x79 = 121 → (121 × 200 ÷ 256 − 100) = -5.46875 %

Formula
(val × 200 ÷ 256 − 100)
Range
-100 to 99.21 %
Unit
%

Confirmed for 2010 to 2011, 2014 to 2015, 2018 to 2020. In testing for 1999, 2001 to 2004, 2009, 2012 to 2013, 2016, 2022, 2026. Supported for 2005 to 2008. Not supported for 2000, 2017, 2021, 2023 to 2025.

Starter relay on TUNDRA_STARTER_RELAY_ON

  • Request21 39
  • Service 21PID 39
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bit 47 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 1999 to 2022, 2026. Not supported for 2023 to 2025.

Steering angle TUNDRA_STEER_ANG

  • Request22 10 09
  • Service 22DID 1009
  • Module7B1 → 7B9
  • Every250 ms
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
(val ÷ 10 − 3276.8)
Range
-20 to 150 °
Unit
°

In testing for 1999 to 2007, 2009 to 2014, 2016 to 2017, 2020 to 2022, 2026. Not supported for 2008, 2015, 2018 to 2019, 2023 to 2025.

Stroke open TUNDRA_STROKE_OPENConfirmed

  • Request21 BE
  • Service 21PID BE
  • Module7B0 → 7B8
  • Every1 s
  • Testing for 1999 to 2017, 2022 to 2026

Example reply from a 2021 Toyota Tundra.

Bit 10 of the reply.

0b0 = 0 → 0

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2018 to 2021. In testing for 1999, 2001 to 2004, 2009, 2012 to 2013, 2016, 2022, 2026. Not supported for 2000, 2005 to 2008, 2010 to 2011, 2014 to 2015, 2017, 2023 to 2025.

Synchronize stroke sensor position TUNDRA_SYNCHRONIZE_STROKE

  • Request22 16 34
  • Service 22DID 1634
  • Module701 → 709
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 256 ÷ 65535)
Range
0 to 256 mm
Unit
mm

In testing for 1999 to 2007, 2009 to 2014, 2016 to 2017, 2020 to 2022, 2026. Not supported for 2008, 2015, 2018 to 2019, 2023 to 2025.

System guard on TUNDRA_SYSTEM_GUARD_ONConfirmed

  • Request21 41
  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing for 1999 to 2017, 2020 to 2026

Example reply from a 2019 Toyota Tundra.

Bit 144 of the reply.

0b1 = 1 → 1

Formula
val
Range
0 to 1
Unit
Number

Confirmed for 2018 to 2019. In testing for 1999 to 2017, 2020 to 2022, 2026. Not supported for 2023 to 2025.

Throttle fully close learn TUNDRA_THROTTLE_FULLY_CLOSEConfirmed

  • Request21 41
  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing for 1999 to 2017, 2020 to 2026

Bits 112 to 119 of the reply, 8 bits.

Formula
(val × 5 ÷ 256)
Range
0 to 4.98 V
Unit
V

Confirmed for 2018 to 2019. In testing for 1999 to 2017, 2020 to 2022, 2026. Not supported for 2023 to 2025.

Throttle idle position on TUNDRA_THROTTLE_IDLE_POS_ONConfirmed

  • Request21 41
  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing for 1999 to 2017, 2020 to 2026

Example reply from a 2019 Toyota Tundra.

Bit 149 of the reply.

0b1 = 1 → 1

Formula
val
Range
0 to 1
Unit
Number

Confirmed for 2018 to 2019. In testing for 1999 to 2017, 2020 to 2022, 2026. Not supported for 2023 to 2025.

Throttle motor current TUNDRA_THROTTLE_MOTORConfirmed

  • Request21 41
  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing for 1999 to 2017, 2020 to 2026

Bits 136 to 143 of the reply, 8 bits.

Formula
(val × 5 ÷ 64)
Range
0 to 19.9 A
Unit
A

Confirmed for 2018 to 2019. In testing for 1999 to 2017, 2020 to 2022, 2026. Not supported for 2023 to 2025.

Throttle motor duty, close TUNDRA_THROTTLE_MOTOR_DUTY_CLOSEConfirmed

  • Request21 41
  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing for 1999 to 2017, 2020 to 2026

Example reply from a 2019 Toyota Tundra.

Bits 128 to 135 of the reply, 8 bits.

0x05 = 5 → 5 %

Formula
val
Range
0 to 255 %
Unit
%

Confirmed for 2018 to 2019. In testing for 1999 to 2017, 2020 to 2022, 2026. Not supported for 2023 to 2025.

Throttle motor duty, open TUNDRA_THROTTLE_MOTOR_DUTY_OPENConfirmed

  • Request21 41
  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing for 1999 to 2017, 2020 to 2026

Example reply from a 2019 Toyota Tundra.

Bits 120 to 127 of the reply, 8 bits.

0x00 = 0 → 0 %

Formula
val
Range
0 to 255 %
Unit
%

Confirmed for 2018 to 2019. In testing for 1999 to 2017, 2020 to 2022, 2026. Not supported for 2023 to 2025.

Throttle position TUNDRA_THROTTLE_21

  • Request21 11
  • Service 21PID 11
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 20 ÷ 51)
Range
0 to 100 %
Unit
%

In testing for 1999 to 2022, 2026. Not supported for 2023 to 2025.

Throttle position command TUNDRA_THROTTLE_POS_COMMANDConfirmed

  • Request21 41
  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing for 1999 to 2017, 2020 to 2026

Example reply from a 2019 Toyota Tundra.

Bits 32 to 39 of the reply, 8 bits.

0x30 = 48 → (48 × 5 ÷ 256) = 0.9375 V

Formula
(val × 5 ÷ 256)
Range
0 to 4.98 V
Unit
V

Confirmed for 2018 to 2019. In testing for 1999 to 2017, 2020 to 2022, 2026. Not supported for 2023 to 2025.

Throttle position, number 1 TUNDRA_THROTTLE_POS_NUMBER_1Confirmed

  • Request21 41
  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing for 1999 to 2017, 2020 to 2026

Example reply from a 2019 Toyota Tundra.

Bits 88 to 95 of the reply, 8 bits.

0x30 = 48 → (48 × 5 ÷ 256) = 0.9375 V

Formula
(val × 5 ÷ 256)
Range
0 to 4.98 V
Unit
V

Confirmed for 2018 to 2019. In testing for 1999 to 2017, 2020 to 2022, 2026. Not supported for 2023 to 2025.

Throttle position, number 2 TUNDRA_THROTTLE_POS_NUMBER_2Confirmed

  • Request21 41
  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing for 1999 to 2017, 2020 to 2026

Example reply from a 2019 Toyota Tundra.

Bits 96 to 103 of the reply, 8 bits.

0x82 = 130 → (130 × 5 ÷ 256) = 2.539063 V

Formula
(val × 5 ÷ 256)
Range
0 to 4.98 V
Unit
V

Confirmed for 2018 to 2019. In testing for 1999 to 2017, 2020 to 2022, 2026. Not supported for 2023 to 2025.

Throttle require position TUNDRA_THROTTLE_REQUIRE_POSConfirmed

  • Request21 41
  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing for 1999 to 2017, 2020 to 2026

Example reply from a 2019 Toyota Tundra.

Bits 104 to 111 of the reply, 8 bits.

0x30 = 48 → (48 × 5 ÷ 256) = 0.9375 V

Formula
(val × 5 ÷ 256)
Range
0 to 4.98 V
Unit
V

Confirmed for 2018 to 2019. In testing for 1999 to 2017, 2020 to 2022, 2026. Not supported for 2023 to 2025.

Throttle sensor open position 1 TUNDRA_THROTTLE_SENS_OPEN_1Confirmed

  • Request21 41
  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing for 1999 to 2017, 2020 to 2026

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 5 ÷ 256)
Range
0 to 4.98 V
Unit
V

Confirmed for 2018 to 2019. In testing for 1999 to 2017, 2020 to 2022, 2026. Not supported for 2023 to 2025.

Throttle sensor open position 2 TUNDRA_THROTTLE_SENS_OPEN_2Confirmed

  • Request21 41
  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing for 1999 to 2017, 2020 to 2026

Bits 8 to 15 of the reply, 8 bits.

Formula
(val × 5 ÷ 256)
Range
0 to 4.98 V
Unit
V

Confirmed for 2018 to 2019. In testing for 1999 to 2017, 2020 to 2022, 2026. Not supported for 2023 to 2025.

Throttle sensor position TUNDRA_THROTTLE_SENSOR_POSITIONConfirmed

  • Request21 01
  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1999 to 2004, 2009, 2012 to 2013, 2022 to 2026

Example reply from a 2021 Toyota Tundra.

Bits 112 to 119 of the reply, 8 bits.

0x00 = 0 → (0 × 100 ÷ 255) = 0 %

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

Confirmed for 2010 to 2011, 2015, 2018 to 2021. In testing for 1999, 2001 to 2004, 2009, 2012 to 2013, 2022, 2026. Supported for 2005 to 2008. Not supported for 2000, 2023 to 2025.

Throttle sensor position TUNDRA_THROTTLE_SENSOR_POSITION_V2Confirmed

  • Request21 01
  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2016

Example reply from a 2017 Toyota Tundra.

Bits 104 to 111 of the reply, 8 bits.

0x00 = 0 → (0 × 100 ÷ 255) = 0 %

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

Confirmed for 2014, 2017. In testing for 2016.

Total fuel trim, bank 1 TUNDRA_TOT_FT_1Confirmed

  • Request21 3C
  • Service 21PID 3C
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1999 to 2017, 2019 to 2026

Example reply from a 2018 Toyota Tundra.

Bits 32 to 39 of the reply, 8 bits.

0x80 = 128 → (128 × 100 ÷ 256 − 50) = 0 %

Formula
(val × 100 ÷ 256 − 50)
Range
-50 to 49.6 %
Unit
%

Confirmed for 2018. In testing for 1999 to 2017, 2019 to 2022, 2026. Not supported for 2023 to 2025.

Transaxle oil temperature TUNDRA_TRANSAXLE_OIL_TConfirmed

  • Request22 10 40
  • Service 22DID 1040
  • Module7D2 → 7DA
  • Every1 s
  • Testing for 2026

Example reply from a 2025 Toyota Tundra.

Bits 16 to 23 of the reply, 8 bits.

0x84 = 132 → (132 − 40) = 92 °C

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2022 to 2025. In testing for 2026. Not supported for 2000, 2005 to 2008, 2010 to 2012, 2014 to 2015, 2017 to 2021.

Transmission fluid pan temperature TUNDRA_TF1_PANConfirmed

Pelican can show this parameter as the transmission fluid temperature.

  • Request22 16 27
  • Service 22DID 1627
  • Module701 → 709
  • Every5 s
  • Testing for 1999 to 2021, 2026

Example reply from a 2025 Toyota Tundra.

Bits 0 to 15 of the reply, 16 bits.

0x2800 = 10240 → (10240 × 0.00703125 − 40) = 32 °F

Formula
(val × 0.00703125 − 40)
Range
-40 to 350 °F
Unit
°F

Confirmed for 2022 to 2025. In testing for 1999, 2001 to 2004, 2009, 2013, 2026. Not supported for 2000, 2005 to 2008, 2010 to 2012, 2014 to 2021.

Transmission fluid post-converter temperature TUNDRA_TF2_CONV

Pelican can show this parameter as the transmission fluid temperature.

  • Request22 16 28
  • Service 22DID 1628
  • Module701 → 709
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 0.00703125 − 40)
Range
-40 to 350 °F
Unit
°F

In testing for 1999, 2001 to 2004, 2009, 2013, 2026. Not supported for 2000, 2005 to 2008, 2010 to 2012, 2014 to 2025.

Transmission fluid temperature TUNDRA_ATF_TEMP_700

Pelican can show this parameter as the transmission fluid temperature.

  • Request22 16 38
  • Service 22DID 1638
  • Module700 → 708
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 1999, 2001 to 2004, 2009, 2013, 2026. Not supported for 2000, 2005 to 2008, 2010 to 2012, 2014 to 2025.

Transmission output shaft speed TUNDRA_TRANS_OUT_RPM

  • Request21 BD
  • Service 21PID BD
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 50)
Range
0 to 12750 rpm
Unit
rpm

In testing for 1999 to 2022, 2026. Not supported for 2023 to 2025.

Turbine speed TUNDRA_SPD_NT

  • Request21 81
  • Service 21PID 81
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 50)
Range
0 to 12750 rpm
Unit
rpm

In testing for 1999 to 2022, 2026. Not supported for 2023 to 2025.

Valvematic current angle TUNDRA_VALVEMATIC_CURRENT

  • Request21 31
  • Service 21PID 31
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 5 ÷ 512)
Range
0 to 639.9 °
Unit
°

In testing for 1999 to 2022, 2026. Not supported for 2023 to 2025.

Valvematic, target angle TUNDRA_VALVEMATIC_TGT_ANG

  • Request21 3A
  • Service 21PID 3A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 5 ÷ 512)
Range
0 to 639.9 °
Unit
°

In testing for 1999 to 2022, 2026. Not supported for 2023 to 2025.

Variable valve timing aim angle 1 TUNDRA_VARIABLE_VLV_TIM_AIM_1Confirmed

  • Request21 44
  • Service 21PID 44
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1999 to 2017, 2019 to 2026

Example reply from a 2018 Toyota Tundra.

Bits 0 to 15 of the reply, 16 bits.

0x1FE9 = 8169 → (8169 × 1333 ÷ 218450) = 49.847915 %

Formula
(val × 1333 ÷ 218450)
Range
0 to 399 %
Unit
%

Confirmed for 2018. In testing for 1999 to 2017, 2019 to 2022, 2026. Not supported for 2023 to 2025.

Variable valve timing change angle 1 TUNDRA_VARIABLE_VLV_TIM_1Confirmed

  • Request21 44
  • Service 21PID 44
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1999 to 2017, 2019 to 2026

Bits 32 to 47 of the reply, 16 bits.

Formula
(val × 0.0097642481)
Range
0 to 639 °
Unit
°

Confirmed for 2018. In testing for 1999 to 2017, 2019 to 2022, 2026. Not supported for 2023 to 2025.

Variable valve timing control status 1 on TUNDRA_VARIABLE_VLV_TIM_1_ON

  • Request21 39
  • Service 21PID 39
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bit 22 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 1999 to 2022, 2026. Not supported for 2023 to 2025.

Variable valve timing oil control valve duty 1 TUNDRA_VARIABLE_VLV_TIM_OIL_1Confirmed

  • Request21 44
  • Service 21PID 44
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1999 to 2017, 2019 to 2026

Example reply from a 2018 Toyota Tundra.

Bits 16 to 31 of the reply, 16 bits.

0x1CA9 = 7337 → (7337 × 0.0061020829) = 44.770982 %

Formula
(val × 0.0061020829)
Range
0 to 399 %
Unit
%

Confirmed for 2018. In testing for 1999 to 2017, 2019 to 2022, 2026. Not supported for 2023 to 2025.

Variable valve timing oil temperature TUNDRA_VVTOTConfirmed

  • Request21 51
  • Service 21PID 51
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1999 to 2009, 2011, 2013, 2022 to 2026

Example reply from a 2021 Toyota Tundra.

Bits 56 to 63 of the reply, 8 bits.

0x83 = 131 → (131 − 40) = 91 °C

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2010, 2012, 2014 to 2021. In testing for 1999, 2001 to 2004, 2009, 2013, 2026. Not supported for 2000, 2005 to 2008, 2011, 2022 to 2025.

Variable valve timing opening angle bank 1 TUNDRA_VVT_IE_OPENING_ANGLE_BANK_1

  • Request22 28 43
  • Service 22DID 2843
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 1999, 2001 to 2004, 2009, 2012 to 2013, 2016, 2022, 2026. Not supported for 2000, 2005 to 2008, 2010 to 2011, 2014 to 2015, 2017 to 2021, 2023 to 2025.

Vehicle speed TUNDRA_VSS_21

  • Request21 0D
  • Service 21PID 0D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 1999 to 2022, 2026. Not supported for 2023 to 2025.

Vehicle speed sensor test result, incomplete TUNDRA_SPD_TEST_RESULT

  • Request21 E3
  • Service 21PID E3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 1999 to 2022, 2026. Not supported for 2023 to 2025.

Engine › Catalyst

Catalyst temperature, bank 1 sensor 1 TUNDRA_CAT_T_11Confirmed

  • Request22 1F 3C
  • Service 22DID 1F3C
  • Module700 → 708
  • Every5 s
  • Testing for 1999 to 2021, 2026

Example reply from a 2025 Toyota Tundra.

Bits 0 to 15 of the reply, 16 bits.

0x01DE = 478 → (478 ÷ 10 − 40) = 7.8 °C

Formula
(val ÷ 10 − 40)
Range
-40 to 6513.5 °C
Unit
°C

Confirmed for 2022 to 2025. In testing for 1999, 2001 to 2004, 2009, 2013, 2016, 2026. Not supported for 2000, 2005 to 2008, 2010 to 2012, 2014 to 2015, 2017 to 2021.

Catalyst temperature, bank 1 sensor 2 TUNDRA_CAT_T_12Confirmed

  • Request22 1F 3E
  • Service 22DID 1F3E
  • Module700 → 708
  • Every5 s
  • Testing for 1999 to 2021, 2026

Example reply from a 2025 Toyota Tundra.

Bits 0 to 15 of the reply, 16 bits.

0x01D9 = 473 → (473 ÷ 10 − 40) = 7.3 °C

Formula
(val ÷ 10 − 40)
Range
-40 to 6513.5 °C
Unit
°C

Confirmed for 2022 to 2025. In testing for 1999, 2001 to 2004, 2009, 2013, 2016, 2026. Not supported for 2000, 2005 to 2008, 2010 to 2012, 2014 to 2015, 2017 to 2021.

Engine › Misfires

All cylinders misfire count TUNDRA_ALL_CYLINDERS_MISFIRE_CNTConfirmed

  • Request21 45
  • Service 21PID 45
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1999 to 2004, 2009, 2012 to 2013, 2016, 2022 to 2026

Example reply from a 2021 Toyota Tundra.

Bits 56 to 63 of the reply, 8 bits.

0x00 = 0 → 0

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2010 to 2011, 2014 to 2015, 2017 to 2021. In testing for 1999, 2001 to 2004, 2009, 2012 to 2013, 2016, 2022, 2026. Supported for 2005 to 2008. Not supported for 2000, 2023 to 2025.

Cylinder #1 misfire count TUNDRA_CYL1_MISFIRE_CNTConfirmed

  • Request21 45
  • Service 21PID 45
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1999 to 2004, 2009, 2012 to 2013, 2016, 2022 to 2026

Example reply from a 2021 Toyota Tundra.

Bits 24 to 31 of the reply, 8 bits.

0x00 = 0 → 0

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2010 to 2011, 2014 to 2015, 2017 to 2021. In testing for 1999, 2001 to 2004, 2009, 2012 to 2013, 2016, 2022, 2026. Supported for 2005 to 2008. Not supported for 2000, 2023 to 2025.

Cylinder #2 misfire count TUNDRA_CYL2_MISFIRE_CNTConfirmed

  • Request21 45
  • Service 21PID 45
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1999 to 2004, 2009, 2012 to 2013, 2016, 2022 to 2026

Example reply from a 2021 Toyota Tundra.

Bits 32 to 39 of the reply, 8 bits.

0x00 = 0 → 0

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2010 to 2011, 2014 to 2015, 2017 to 2021. In testing for 1999, 2001 to 2004, 2009, 2012 to 2013, 2016, 2022, 2026. Supported for 2005 to 2008. Not supported for 2000, 2023 to 2025.

Cylinder #3 misfire count TUNDRA_CYL3_MISFIRE_CNTConfirmed

  • Request21 45
  • Service 21PID 45
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1999 to 2004, 2009, 2012 to 2013, 2016, 2022 to 2026

Example reply from a 2021 Toyota Tundra.

Bits 40 to 47 of the reply, 8 bits.

0x00 = 0 → 0

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2010 to 2011, 2014 to 2015, 2017 to 2021. In testing for 1999, 2001 to 2004, 2009, 2012 to 2013, 2016, 2022, 2026. Supported for 2005 to 2008. Not supported for 2000, 2023 to 2025.

Cylinder #4 misfire count TUNDRA_CYL4_MISFIRE_CNTConfirmed

  • Request21 45
  • Service 21PID 45
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1999 to 2004, 2009, 2012 to 2013, 2016, 2022 to 2026

Example reply from a 2021 Toyota Tundra.

Bits 48 to 55 of the reply, 8 bits.

0x00 = 0 → 0

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2010 to 2011, 2014 to 2015, 2017 to 2021. In testing for 1999, 2001 to 2004, 2009, 2012 to 2013, 2016, 2022, 2026. Supported for 2005 to 2008. Not supported for 2000, 2023 to 2025.

Misfire load TUNDRA_MISFIRE_LOAD_7E0Confirmed

  • Request21 45
  • Service 21PID 45
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1999 to 2004, 2009, 2012 to 2013, 2016, 2022 to 2026

Example reply from a 2021 Toyota Tundra.

Bits 16 to 23 of the reply, 8 bits.

0x00 = 0 → (0 × 4 ÷ 256) = 0

Formula
(val × 4 ÷ 256)
Range
0 to 3.98
Unit
Number

Confirmed for 2010 to 2011, 2014 to 2015, 2017 to 2021. In testing for 1999, 2001 to 2004, 2009, 2012 to 2013, 2016, 2022, 2026. Supported for 2005 to 2008. Not supported for 2000, 2023 to 2025.

Misfire margin TUNDRA_MISFIRE_MARGIN_7E0Confirmed

  • Request21 45
  • Service 21PID 45
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1999 to 2004, 2009, 2012 to 2013, 2016, 2022 to 2026

Example reply from a 2021 Toyota Tundra.

Bits 80 to 87 of the reply, 8 bits.

0x00 = 0 → (0 − 128) = -128 %

Formula
(val − 128)
Range
-128 to 127 %
Unit
%

Confirmed for 2010 to 2011, 2014 to 2015, 2017 to 2021. In testing for 1999, 2001 to 2004, 2009, 2012 to 2013, 2016, 2022, 2026. Supported for 2005 to 2008. Not supported for 2000, 2023 to 2025.

Engine › OxygenSensors

Lambda value, Equivalence Ratio Bank 1, Sensor 1 LAMBDA11_CURRENTSAE J1979Confirmed

Pelican can show this parameter as the O2 lambda.

  • Request01 34
  • Service 01PID 34
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 32768)
Range
0 to 1.99
Unit
Number

Confirmed for 2007, 2019, 2021, 2024. Supported for 2006, 2008, 2010 to 2012, 2014 to 2015, 2017 to 2018, 2020, 2023, 2025.

Lambda value, Equivalence Ratio Bank 1, Sensor 1 LAMBDA11_VOLTSAE J1979Confirmed

Pelican can show this parameter as the O2 lambda.

  • Request01 24
  • Service 01PID 24
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 32768)
Range
0 to 1.99
Unit
Number

Confirmed for 2005 to 2007, 2019, 2021. Supported for 2008, 2010 to 2018, 2020.

Wide Range O2S Current, O2 Sensor Bank 1, Sensor 1 O2S11_CURRENTSAE J1979Confirmed

  • Request01 34
  • Service 01PID 34
  • Module7E0 → 7E8
  • Every250 ms

Bits 16 to 31 of the reply, 16 bits.

Formula
(val ÷ 256 − 128)
Range
-128 to 127.996 mA
Unit
mA

Confirmed for 2007, 2019, 2021, 2024. Supported for 2006, 2008, 2010 to 2012, 2014 to 2015, 2017 to 2018, 2020, 2023, 2025.

Wide Range O2S Voltage, O2 Sensor Bank 1, Sensor 1 O2S11_VOLTSAE J1979Confirmed

  • Request01 24
  • Service 01PID 24
  • Module7E0 → 7E8
  • Every250 ms

Bits 16 to 31 of the reply, 16 bits.

Formula
(val ÷ 8196)
Range
0 to 7.999 V
Unit
V

Confirmed for 2005 to 2007, 2019, 2021. Supported for 2008, 2010 to 2018, 2020.