ECU parameters
The Toyota Tacoma has 7 ECU parameters.
● Confirmed◆ In testing○ Supported× Not supported
Brake assist status TACOMA_BA_CTRLConfirmed
- Request
21 5F - Service 21
PID 5F - Module
7B0 → 7B8 - Every
1 s - Testing for 1995 to 2009, 2011, 2015, 2024 to 2026
Example reply from a 2023 Toyota Tacoma.
Bit 11 of the reply.
0b0 = 0 → 0
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
Confirmed for 2010, 2012 to 2014, 2016 to 2023. In testing for 1995 to 2005, 2009, 2015. Not supported for 2006 to 2008, 2011, 2024 to 2026.
Inspection mode TACOMA_INSPECTION_MODEConfirmed
- Request
21 A6 - Service 21
PID A6 - Module
7B0 → 7B8 - Every
60 s - Testing for 1995 to 2009, 2011, 2015, 2024 to 2026
Example reply from a 2023 Toyota Tacoma.
Bit 0 of the reply.
0b0 = 0 → 0
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
Confirmed for 2010, 2012 to 2014, 2016 to 2023. In testing for 1995 to 2005, 2009, 2015. Not supported for 2006 to 2008, 2011, 2024 to 2026.
Main idle TACOMA_MAIN_IDLE_SWConfirmed
- Request
21 1D - Service 21
PID 1D - Module
7B0 → 7B8 - Every
1 s - Testing for 1995 to 2009, 2011, 2015, 2024 to 2026
Example reply from a 2023 Toyota Tacoma.
Bit 2 of the reply.
0b1 = 1 → 1
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
Confirmed for 2010, 2012 to 2014, 2016 to 2023. In testing for 1995 to 2005, 2009, 2015. Not supported for 2006 to 2008, 2011, 2024 to 2026.
Predictive brake assist status TACOMA_PBA_CTRLConfirmed
- Request
21 5F - Service 21
PID 5F - Module
7B0 → 7B8 - Every
1 s - Testing for 1995 to 2009, 2011, 2015, 2024 to 2026
Example reply from a 2023 Toyota Tacoma.
Bit 12 of the reply.
0b0 = 0 → 0
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
Confirmed for 2010, 2012 to 2014, 2016 to 2023. In testing for 1995 to 2005, 2009, 2015. Not supported for 2006 to 2008, 2011, 2024 to 2026.
Reservoir warning TACOMA_RESERVOIR_WARNING_SWConfirmed
- Request
21 1D - Service 21
PID 1D - Module
7B0 → 7B8 - Every
1 s - Testing for 1995 to 2009, 2011, 2015, 2024 to 2026
Example reply from a 2023 Toyota Tacoma.
Bit 1 of the reply.
0b0 = 0 → 0
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
Confirmed for 2010, 2012 to 2014, 2016 to 2023. In testing for 1995 to 2005, 2009, 2015. Not supported for 2006 to 2008, 2011, 2024 to 2026.
VVT-ie duty ratio bank 1 TACOMA_VVT_IE_DUTY_RATIO_1
- Request
22 10 8A - Service 22
DID 108A - Module
700 → 708 - Every
1 s - Testing
Bits 0 to 14 of the reply, 15 bits.
- Formula
(val × 399.9 ÷ 65535 − 200)- Range
- -200 to -0.0531 %
- Unit
- %
In testing for 1995 to 2011, 2015 to 2016, 2020, 2026. Not supported for 2012 to 2014, 2017 to 2019, 2021 to 2025.
VVT-ie motor direction: forward bank 1 TACOMA_VVT_IE_MOTOR_DIRECTION_FORWARD_1
- Request
22 10 8A - Service 22
DID 108A - Module
700 → 708 - Every
1 s - Testing
Bit 15 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 1995 to 2011, 2015 to 2016, 2020, 2026. Not supported for 2012 to 2014, 2017 to 2019, 2021 to 2025.