DTC parameters
The Toyota Grand Highlander has 24 DTC parameters.
● Confirmed◆ In testing○ Supported× Not supported
2nd air monitor available? GH_2ND_AIR_MONITOR_AVAIL
- Request
21 06 - Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 20 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
In testing for 2023. Not supported for 2024 to 2026.
2nd air monitor incomplete? GH_2ND_AIR_MONITOR_INCMPL
- Request
21 06 - Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 28 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
In testing for 2023. Not supported for 2024 to 2026.
A/C monitor available? GH_A_C_MONITOR_AVAIL
- Request
21 06 - Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 19 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
In testing for 2023. Not supported for 2024 to 2026.
A/C monitor incomplete? GH_A_C_MONITOR_INCMPL
- Request
21 06 - Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 27 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
In testing for 2023. Not supported for 2024 to 2026.
Catalyst monitor available? GH_CATALYST_MONITOR_AVAIL
- Request
21 06 - Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 23 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
In testing for 2023. Not supported for 2024 to 2026.
Catalyst monitor incomplete? GH_CATALYST_MONITOR_INCMPL
- Request
21 06 - Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 31 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
In testing for 2023. Not supported for 2024 to 2026.
Complete parts monitor available? GH_COMPLETE_PARTS_MONITOR_AVAIL
- Request
21 06 - Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 13 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
In testing for 2023. Not supported for 2024 to 2026.
Distance traveled since diagnostic trouble codes cleared CLR_DISTSAE J1979Confirmed
Distance accumulated since DTCs were cleared (via an external test equipment or possibly, a battery disconnect). This parameter is not associated with any particular DTC. It is simply an indication for inspection/maintenance, of the last time an external test equipment was used to clear DTCs. If greater than 65,535 km have occurred, will remain at 65,535 km and not wrap to zero.
Pelican can show this parameter as the distance since trouble codes were cleared.
- Request
01 31 - Service 01
PID 31 - Module
7E0 → 7E8 - Every
15 s
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 km
- Unit
- km
Confirmed for 2025. Supported for 2024, 2026.
EGR/VVT monitor available? GH_EGR_VVT_MONITOR_AVAIL
- Request
21 06 - Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 16 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
In testing for 2023. Not supported for 2024 to 2026.
EGR/VVT monitor incomplete? GH_EGR_VVT_MONITOR_INCMPL
- Request
21 06 - Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 24 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
In testing for 2023. Not supported for 2024 to 2026.
EVAP monitor available? GH_EVAP_MONITOR_AVAIL
- Request
21 06 - Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 21 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
In testing for 2023. Not supported for 2024 to 2026.
EVAP monitor_icmpl GH_EVAP_MONITOR_ICMPL
- Request
21 06 - Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 29 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
In testing for 2023. Not supported for 2024 to 2026.
Fuel system monitor available? GH_FUEL_SYSTEM_MONITOR_AVAIL
- Request
21 06 - Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 14 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
In testing for 2023. Not supported for 2024 to 2026.
Heated catalyst monitor available? GH_HEATED_CATALYST_MONITOR_AVAIL
- Request
21 06 - Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 22 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
In testing for 2023. Not supported for 2024 to 2026.
Heated catalyst monitor incomplete? GH_HEATED_CATALYST_MONITOR_INCMPL
- Request
21 06 - Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 30 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
In testing for 2023. Not supported for 2024 to 2026.
MIL GH_MIL
- Request
21 06 - Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 0 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2023. Not supported for 2024 to 2026.
MIL ON run distance GH_MILON_RUN_DISTANCE
- Request
21 06 - Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 48 to 63 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 km
- Unit
- km
In testing for 2023. Not supported for 2024 to 2026.
Misfire monitor available? GH_MISFIRE_MONITOR_AVAIL
- Request
21 06 - Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 15 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
In testing for 2023. Not supported for 2024 to 2026.
Number of emission DTC GH_NUMBER_OF_EMISSION_DTC
- Request
21 06 - Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 1 to 7 of the reply, 7 bits.
- Formula
val- Range
- 0 to 127
- Unit
- Number
In testing for 2023. Not supported for 2024 to 2026.
O2S heater monitor available? GH_O2S_A_FS_HEATER_MONITOR_AVAIL
- Request
21 06 - Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 17 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
In testing for 2023. Not supported for 2024 to 2026.
O2S heater monitor incomplete? GH_O2S_A_FS_HEATER_MONITOR_INCMPL
- Request
21 06 - Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 25 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
In testing for 2023. Not supported for 2024 to 2026.
O2S monitor available? GH_O2S_A_FS_MONITOR_AVAIL
- Request
21 06 - Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 18 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
In testing for 2023. Not supported for 2024 to 2026.
O2S monitor incomplete? GH_O2S_A_FS_MONITOR_INCMPL
- Request
21 06 - Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 26 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
In testing for 2023. Not supported for 2024 to 2026.
Running time from MIL ON GH_RUNNING_TIME_FROM_MIL_ON
- Request
21 06 - Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 min
- Unit
- min
In testing for 2023. Not supported for 2024 to 2026.