Engine parameters
The Renault Clio has 197 engine parameters.
● Confirmed◆ In testing○ Supported× Not supported
ABS RENAULT_ABS
- Request
22 4B 35 - Service 22
DID 4B35 - Module
740 → 760 - Every
1 s - Testing
Bit 2 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2026.
ABS, warning RENAULT_ABS_WARN
- Request
22 4B 35 - Service 22
DID 4B35 - Module
740 → 760 - Every
1 s - Testing
Bit 3 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2026.
Absolute load value LOAD_ABSSAE J1979Confirmed
- Request
01 43 - Service 01
PID 43 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 25700 %
- Unit
- %
Confirmed for 2017, 2021, 2023. Supported for 2018 to 2020, 2024.
Accelerator pedal detection blocked RENAULT_ACCEL_DETECT_BLOCKED
- Request
22 20 36 - Service 22
DID 2036 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1990 to 2026.
Accelerator pedal potentiometer voltage, track 1 RENAULT_ACCEL_POT_V1
- Request
22 20 0B - Service 22
DID 200B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2026.
Accelerator pedal potentiometer voltage, track 2 RENAULT_ACCEL_POT_V2
- Request
22 20 0C - Service 22
DID 200C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2026.
Actual engine torque TQ_ACTSAE J1979Confirmed
- Request
01 62 - Service 01
PID 62 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 125)- Range
- -125 to 130 %
- Unit
- %
Confirmed for 2021, 2023. Supported for 2019 to 2020, 2024.
Air flow rate from mass air flow sensor MAFSAE J1979Confirmed
Pelican can show this parameter as the mass air flow.
- Request
01 10 - Service 01
PID 10 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655.35 g/s
- Unit
- g/s
Confirmed for 2023. Supported for 2016, 2020.
Air inlet temperature sensor voltage RENAULT_AIR_INLET_T_SNS_V
- Request
22 FD 83 - Service 22
DID FD83 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.99975 V
- Unit
- V
In testing for 1990 to 2026.
Anti-rollover control RENAULT_ANTI_ROLL
- Request
22 4B 35 - Service 22
DID 4B35 - Module
740 → 760 - Every
1 s - Testing
Bit 24 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2026.
Anti-rollover control, warning RENAULT_ANTI_ROLL_WARN
- Request
22 4B 35 - Service 22
DID 4B35 - Module
740 → 760 - Every
1 s - Testing
Bit 25 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2026.
Barometric pressure BAROSAE J1979Confirmed
Normally obtained from one of a dedicated barometric sensor, a MAP sensor at key-on and during certain modes of driving, or inferred from a MAF sensor and other inputs during certain modes of driving. The control module reports BARO from whatever source it is derived from.
- Request
01 33 - Service 01
PID 33 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 kPa
- Unit
- kPa
Confirmed for 2021, 2023. Supported for 2016 to 2020, 2024.
Boost pressure RENAULT_BOOST_P
- Request
22 24 01 - Service 22
DID 2401 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 bar
- Unit
- bar
In testing for 1990 to 2026.
Boost pressure sensor A BP_A_ACTSAE J1979Confirmed
Actual turbocharger/supercharger A boost pressure.
- Request
01 70 - Service 01
PID 70 - Module
7E0 → 7E8 - Every
250 ms
Bits 24 to 39 of the reply, 16 bits.
- Formula
(val ÷ 32)- Range
- 0 to 2047.96875 kPa
- Unit
- kPa
Confirmed for 2021. Supported for 2019 to 2020, 2024.
Boost pressure sensor B BP_B_ACTSAE J1979Confirmed
Actual turbocharger/supercharger B boost pressure.
- Request
01 70 - Service 01
PID 70 - Module
7E0 → 7E8 - Every
250 ms
Bits 56 to 71 of the reply, 16 bits.
- Formula
(val ÷ 32)- Range
- 0 to 2047.96875 kPa
- Unit
- kPa
Confirmed for 2021. Supported for 2019 to 2020, 2024.
Brake contact duration 1 RENAULT_BRAKE_CONTACT_1_DUR
- Request
22 20 6A - Service 22
DID 206A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 s
- Unit
- s
In testing for 1990 to 2026.
Brake contact duration 2 RENAULT_BRAKE_CONTACT_2_DUR
- Request
22 20 6B - Service 22
DID 206B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 s
- Unit
- s
In testing for 1990 to 2026.
Brake dive limiter RENAULT_BRAKE_DIVE
- Request
22 4B 35 - Service 22
DID 4B35 - Module
740 → 760 - Every
1 s - Testing
Bit 32 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2026.
Brake dive limiter, warning RENAULT_BRAKE_DIVE_WARN
- Request
22 4B 35 - Service 22
DID 4B35 - Module
740 → 760 - Every
1 s - Testing
Bit 33 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2026.
Brake pedal RENAULT_BRAKE_PEDAL
- Request
22 4B 11 - Service 22
DID 4B11 - Module
740 → 760 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1990 to 2026.
Brake pressure, master cylinder RENAULT_BRAKE_P_MC
- Request
22 4B 0E - Service 22
DID 4B0E - Module
740 → 760 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 bar
- Unit
- bar
In testing for 1990 to 2026.
Braking detected multiplex signal RENAULT_BRAKE_MUX_SIG
- Request
22 20 0F - Service 22
DID 200F - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1990 to 2026.
Calculated engine load LOAD_PCTSAE J1979Confirmed
Represents the amount of work the engine is doing. Expected to reach 100% at wide open throttle/wide open pedal at any altitude, temperature or rpm for both naturally aspirated and boosted engines. If engine load is limited for powertrain protection e.g. engine/turbocharger protection, this value may not reach 100%. For hybrid vehicles, indicates the torque produced only by the internal combustion engine, not the torque being delivered by the entire powertrain. For electric vehicles, the meaning of this parameter is undefined.
Pelican can show this parameter as the engine load.
- Request
01 04 - Service 01
PID 04 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2017, 2020 to 2021, 2023 to 2024. Supported for 2010, 2016, 2018 to 2019.
Camshaft top dead center synchronization RENAULT_CAM_TDC_SYNC
- Request
22 20 14 - Service 22
DID 2014 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1990 to 2026.
Canister bleed solenoid valve RCO RENAULT_CANISTER_BLEED_SOL_RCO
- Request
22 28 22 - Service 22
DID 2822 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 100 ÷ 65535)- Range
- 0 to 100 %
- Unit
- %
In testing for 1990 to 2026.
Catalyst temperature bank 1, sensor 1 CATEMP11SAE J1979Confirmed
- Request
01 3C - Service 01
PID 3C - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10 − 40)- Range
- -40 to 6513.5 °C
- Unit
- °C
Confirmed for 2021, 2023. Supported for 2016, 2019 to 2020, 2024.
Catalyst temperature bank 1, sensor 2 CATEMP12SAE J1979Confirmed
- Request
01 3E - Service 01
PID 3E - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10 − 40)- Range
- -40 to 6513.5 °C
- Unit
- °C
Confirmed for 2021. Supported for 2016, 2020, 2024.
Clutch contact wire connection RENAULT_CLUTCH_CONTACT_WIRE
- Request
22 20 6D - Service 22
DID 206D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1990 to 2026.
Clutch pedal switch RENAULT_CLUTCH_PEDAL_SW
- Request
22 22 2D - Service 22
DID 222D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1990 to 2026.
Clutch start-of-travel switch RENAULT_CLUTCH_TRAVEL_SW
- Request
22 20 59 - Service 22
DID 2059 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 7 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 1990 to 2026.
Clutch temperature RENAULT_CLUTCH_T
- Request
22 30 20 - Service 22
DID 3020 - Module
748 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 °C
- Unit
- °C
In testing for 1990 to 2026.
Commanded boost pressure A BP_A_CMDSAE J1979Confirmed
Turbocharger/supercharger A commanded boost pressure.
- Request
01 70 - Service 01
PID 70 - Module
7E0 → 7E8 - Every
250 ms
Bits 8 to 23 of the reply, 16 bits.
- Formula
(val ÷ 32)- Range
- 0 to 2047.96875 kPa
- Unit
- kPa
Confirmed for 2021. Supported for 2019 to 2020, 2024.
Commanded boost pressure B BP_B_CMDSAE J1979Confirmed
Turbocharger/supercharger B commanded boost pressure.
- Request
01 70 - Service 01
PID 70 - Module
7E0 → 7E8 - Every
250 ms
Bits 40 to 55 of the reply, 16 bits.
- Formula
(val ÷ 32)- Range
- 0 to 2047.96875 kPa
- Unit
- kPa
Confirmed for 2021. Supported for 2019 to 2020, 2024.
Commanded EGR EGR_PCTSAE J1979Confirmed
- Request
01 2C - Service 01
PID 2C - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2023. Supported for 2016, 2020.
Commanded equivalence ratio EQ_RATSAE J1979Confirmed
Fuel systems that utilize conventional oxygen sensor display the inverse of the commanded open loop equivalence ratio (also known as lambda) while the fuel control system is in open loop. Will indicate 1.000 while in closed-loop fuel.
Pelican can show this parameter as the commanded lambda.
- Request
01 44 - Service 01
PID 44 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 2 ÷ 65535)- Range
- 0 to 1.99
- Unit
- Number
Confirmed for 2020 to 2021, 2023 to 2024. Supported for 2017 to 2019.
Commanded evaporative purge EVAP_PCTSAE J1979Confirmed
- Request
01 2E - Service 01
PID 2E - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2017, 2021, 2023. Supported for 2018 to 2020, 2024.
Commanded Throttle Actuator A Control TAC_A_CMDSAE J1979Confirmed
- Request
01 6C - Service 01
PID 6C - Module
7E0 → 7E8 - Every
250 ms
Bits 8 to 15 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2021. Supported for 2019 to 2020, 2024.
Commanded Throttle Actuator B Control TAC_B_CMDSAE J1979Confirmed
- Request
01 6C - Service 01
PID 6C - Module
7E0 → 7E8 - Every
250 ms
Bits 24 to 31 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2021. Supported for 2019 to 2020, 2024.
Commanded throttle actuator control TAC_PCTSAE J1979Confirmed
- Request
01 4C - Service 01
PID 4C - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2021, 2023. Supported for 2016 to 2020, 2024.
Commanded wastegate A position WG_A_CMDSAE J1979Confirmed
If an on/off solenoid is used, is 0% when the wastegate is commanded off (allow full boost), 100% when commanded on (dump boost). If a vacuum solenoid is duty cycled, the duty cycle from 0 to 100% is displayed. If a linear or stepper motor valve is used, the fully closed position (full boost) is displayed as 0%, the fully open position (dump boost) is displayed as 100%. Intermediate positions are displayed as a percent of the full-open position. Any other actuation method is normalized to display 0% when the WG is commanded off and 100% when the WG is commanded on.
- Request
01 72 - Service 01
PID 72 - Module
7E0 → 7E8 - Every
250 ms
Bits 8 to 15 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2021. Supported for 2019 to 2020, 2024.
Commanded wastegate B position WG_B_CMDSAE J1979Confirmed
If an on/off solenoid is used, is 0% when the wastegate is commanded off (allow full boost), 100% when commanded on (dump boost). If a vacuum solenoid is duty cycled, the duty cycle from 0 to 100% is displayed. If a linear or stepper motor valve is used, the fully closed position (full boost) is displayed as 0%, the fully open position (dump boost) is displayed as 100%. Intermediate positions are displayed as a percent of the full-open position. Any other actuation method is normalized to display 0% when the WG is commanded off and 100% when the WG is commanded on.
- Request
01 72 - Service 01
PID 72 - Module
7E0 → 7E8 - Every
250 ms
Bits 24 to 31 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2021. Supported for 2019 to 2020, 2024.
Coolant temperature RENAULT_ECT
Pelican can show this parameter as the engine coolant temperature.
- Request
22 20 01 - Service 22
DID 2001 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10 − 273)- Range
- -273 to 6280.5 °C
- Unit
- °C
In testing for 1990 to 2026.
Coolant temperature sensor voltage RENAULT_COOLANT_T_SNS_V
- Request
22 FD 8B - Service 22
DID FD8B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.99975 V
- Unit
- V
In testing for 1990 to 2026.
Coupler RENAULT_COUPLER
- Request
22 30 11 - Service 22
DID 3011 - Module
748 - Every
1 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1990 to 2026.
Crankshaft sync loss counter RENAULT_CRANK_SYNC_LOSS_CNT
- Request
22 21 62 - Service 22
DID 2162 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 1990 to 2026.
Crankshaft synchronization RENAULT_CRANK_SYNC
- Request
22 20 16 - Service 22
DID 2016 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1990 to 2026.
Cylinder 1 knock RENAULT_CYL1_KNOCK
- Request
22 28 47 - Service 22
DID 2847 - Module
7E0 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 1990 to 2026.
Cylinder 1 misfire counter RENAULT_CYL1_MISFIRE_CNT
- Request
22 28 41 - Service 22
DID 2841 - Module
7E0 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 1990 to 2026.
Cylinder 2 knock RENAULT_CYL2_KNOCK
- Request
22 28 48 - Service 22
DID 2848 - Module
7E0 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 1990 to 2026.
Cylinder 2 misfire counter RENAULT_CYL2_MISFIRE_CNT
- Request
22 28 42 - Service 22
DID 2842 - Module
7E0 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 1990 to 2026.
Cylinder 3 knock RENAULT_CYL3_KNOCK
- Request
22 28 49 - Service 22
DID 2849 - Module
7E0 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 1990 to 2026.
Cylinder 3 misfire counter RENAULT_CYL3_MISFIRE_CNT
- Request
22 28 43 - Service 22
DID 2843 - Module
7E0 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 1990 to 2026.
Cylinder 4 knock RENAULT_CYL4_KNOCK
- Request
22 28 4A - Service 22
DID 284A - Module
7E0 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 1990 to 2026.
Cylinder 4 misfire counter RENAULT_CYL4_MISFIRE_CNT
- Request
22 28 44 - Service 22
DID 2844 - Module
7E0 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 1990 to 2026.
Cylinder fuel rate CYL_RATESAE J1979Confirmed
- Request
01 A2 - Service 01
PID A2 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 32)- Range
- 0 to 2047.96875 mg/stroke
- Unit
- mg/stroke
Confirmed for 2021. Supported for 2019 to 2020.
Diagnostic light request RENAULT_OBD_LIGHT_REQ
- Request
22 20 28 - Service 22
DID 2028 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1990 to 2026.
Driver's demand engine torque TQ_DDSAE J1979Confirmed
- Request
01 61 - Service 01
PID 61 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 125)- Range
- -125 to 130 %
- Unit
- %
Confirmed for 2021. Supported for 2019 to 2020, 2024.
EGR error EGR_ERRSAE J1979Confirmed
- Request
01 2D - Service 01
PID 2D - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 128 − 100)- Range
- -100 to 99.22 %
- Unit
- %
Confirmed for 2023. Supported for 2016, 2020.
Electronic brakeforce distribution RENAULT_EBD
- Request
22 4B 35 - Service 22
DID 4B35 - Module
740 → 760 - Every
1 s - Testing
Bit 0 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2026.
Electronic brakeforce distribution, warning RENAULT_EBD_WARN
- Request
22 4B 35 - Service 22
DID 4B35 - Module
740 → 760 - Every
1 s - Testing
Bit 1 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2026.
Emergency braking anticipation RENAULT_EBA_ANT
- Request
22 4B 35 - Service 22
DID 4B35 - Module
740 → 760 - Every
1 s - Testing
Bit 20 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2026.
Emergency braking anticipation, warning RENAULT_EBA_ANT_WARN
- Request
22 4B 35 - Service 22
DID 4B35 - Module
740 → 760 - Every
1 s - Testing
Bit 21 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2026.
Emergency braking assistance RENAULT_EBA_ASSIST
- Request
22 4B 35 - Service 22
DID 4B35 - Module
740 → 760 - Every
1 s - Testing
Bit 15 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2026.
Emergency braking assistance, warning RENAULT_EBA_ASSIST_WARN
- Request
22 4B 35 - Service 22
DID 4B35 - Module
740 → 760 - Every
1 s - Testing
Bit 16 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2026.
Engine coolant temperature ECTSAE J1979Confirmed
Your engine temperature must operate within a certain temperature range to operate efficiently and safely. If it runs too hot, then your engine could be permanently damaged. If it runs too cold, then your engine will use more fuel than necessary.
Pelican can show this parameter as the engine coolant temperature.
- Request
01 05 - Service 01
PID 05 - Module
7E0 → 7E8 - Every
500 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2017, 2020 to 2021, 2023 to 2024. Supported for 2010, 2016, 2018 to 2019.
Engine coolant temperature 1 ECT_1SAE J1979Confirmed
- Request
01 67 - Service 01
PID 67 - Module
7E0 → 7E8 - Every
1 s
Bits 8 to 15 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2021, 2023. Supported for 2019 to 2020, 2024.
Engine coolant temperature 2 ECT_2SAE J1979Confirmed
- Request
01 67 - Service 01
PID 67 - Module
7E0 → 7E8 - Every
1 s
Bits 16 to 23 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2021, 2023. Supported for 2019 to 2020, 2024.
Engine Friction - Percent Torque TQ_FRSAE J1979Confirmed
- Request
01 8E - Service 01
PID 8E - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 125)- Range
- -125 to 130 %
- Unit
- %
Confirmed for 2021, 2023. Supported for 2019 to 2020, 2024.
Engine oil temperature EOTSAE J1979Confirmed
Pelican can show this parameter as the engine oil temperature.
- Request
01 5C - Service 01
PID 5C - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 210 °C
- Unit
- °C
Confirmed for 2017, 2020 to 2021, 2023 to 2024. Supported for 2016, 2019.
Engine oil temperature, estimated RENAULT_EST_OIL_T
Pelican can show this parameter as the engine oil temperature.
- Request
22 20 07 - Service 22
DID 2007 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10 − 273)- Range
- -273 to 6280.5 °C
- Unit
- °C
In testing for 1990 to 2026.
Engine reference torque TQ_REFSAE J1979Confirmed
- Request
01 63 - Service 01
PID 63 - Module
7E0 → 7E8 - Every
86400 s
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 N·m
- Unit
- N·m
Confirmed for 2021, 2023. Supported for 2019 to 2020, 2024.
Engine rotation count RENAULT_ENGINE_ROT_COUNT
- Request
22 21 0E - Service 22
DID 210E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
(val ÷ 1000000)- Range
- 0 to 4294.967295
- Unit
- Number
In testing for 1990 to 2026.
Engine RPM RPMSAE J1979Confirmed
- Request
01 0C - Service 01
PID 0C - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4)- Range
- 0 to 16383.75 rpm
- Unit
- rpm
Confirmed for 2017, 2021, 2023. Supported for 2010, 2016, 2018 to 2020, 2024.
Engine torque RENAULT_ENGINE_TORQUE
- Request
22 20 04 - Service 22
DID 2004 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 32 − 400)- Range
- -400 to 1647.96875 N·m
- Unit
- N·m
In testing for 1990 to 2026.
Engine torque control RENAULT_TORQUE_CTRL
- Request
22 4B 35 - Service 22
DID 4B35 - Module
740 → 760 - Every
1 s - Testing
Bit 12 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2026.
Engine torque control, warning RENAULT_TORQUE_CTRL_WARN
- Request
22 4B 35 - Service 22
DID 4B35 - Module
740 → 760 - Every
1 s - Testing
Bit 13 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2026.
Engine torque, reference RENAULT_ENGINE_TORQUE_REF
- Request
22 30 11 - Service 22
DID 3011 - Module
748 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 2 − 400)- Range
- -16784 to 15983.5 N·m
- Unit
- N·m
In testing for 1990 to 2026.
ESP, deactivated RENAULT_ESP_OFF
- Request
22 4B 35 - Service 22
DID 4B35 - Module
740 → 760 - Every
1 s - Testing
Bit 8 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2026.
Fan high speed request RENAULT_FAN_HI_SPD
- Request
22 20 4A - Service 22
DID 204A - Module
7E0 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1990 to 2026.
First start RENAULT_FIRST_START
- Request
22 20 47 - Service 22
DID 2047 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1990 to 2026.
Flywheel target programming RENAULT_FLYWHEEL_TGT_PROG
- Request
22 21 5B - Service 22
DID 215B - Module
7E0 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1990 to 2026.
Fuel injection timing FUEL_TIMINGSAE J1979Confirmed
Start of main fuel injection relative to Top Dead Center (TDC). Positive degrees indicate before TDC, negative degrees indicate after TDC.
- Request
01 5D - Service 01
PID 5D - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 128 − 38665)- Range
- -210 to 301.992 °
- Unit
- °
Confirmed for 2021. Supported for 2019 to 2020, 2024.
Fuel level, low RENAULT_LOW_FUEL
- Request
22 28 1B - Service 22
DID 281B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1990 to 2026.
Fuel pump control circuit RENAULT_FUEL_PUMP_CTRL
- Request
22 28 1C - Service 22
DID 281C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1990 to 2026.
Heating resistors active count RENAULT_HEAT_RESISTOR_CNT
- Request
22 21 8D - Service 22
DID 218D - Module
7E0 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1990 to 2026.
Hill start assist RENAULT_HILL_START
- Request
22 4B 31 - Service 22
DID 4B31 - Module
740 → 760 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1990 to 2026.
Hydraulic unit temperature RENAULT_HYD_T
- Request
22 4B 17 - Service 22
DID 4B17 - Module
740 → 760 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 °C
- Unit
- °C
In testing for 1990 to 2026.
Idle adaptive correction RENAULT_IDLE_ADAPT_CORR
- Request
22 20 9A - Service 22
DID 209A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 32)- Range
- -1024 to 1023.96875 N·m
- Unit
- N·m
In testing for 1990 to 2026.
Idle regulation integral correction RENAULT_IDLE_REG_INT_CORR
- Request
22 22 46 - Service 22
DID 2246 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 32)- Range
- -1024 to 1023.96875 N·m
- Unit
- N·m
In testing for 1990 to 2026.
Ignition relay on RENAULT_IGN
- Request
22 60 C6 - Service 22
DID 60C6 - Module
745 → 765 - Every
3 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 1990 to 2026.
Ignition timing advance RENAULT_IGN_TIMING_ADV
- Request
22 28 07 - Service 22
DID 2807 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 °
- Unit
- °
In testing for 1990 to 2026.
Improved grip RENAULT_GRIP_CTRL
- Request
22 4B 47 - Service 22
DID 4B47 - Module
740 → 760 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1990 to 2026.
Inlet air temperature RENAULT_INLET_AIR_T
- Request
22 24 3F - Service 22
DID 243F - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10 − 273)- Range
- -273 to 6280.5 °C
- Unit
- °C
In testing for 1990 to 2026.
Inlet camshaft dephaser control OCR RENAULT_IN_CAM_DEPHASER_OCR
- Request
22 20 33 - Service 22
DID 2033 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655.35 %
- Unit
- %
In testing for 1990 to 2026.
Inlet camshaft dephaser setpoint RENAULT_IN_CAM_DEPHASER_SETPT
- Request
22 20 30 - Service 22
DID 2030 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 50)- Range
- 0 to 1310.7 °
- Unit
- °
In testing for 1990 to 2026.
Inlet camshaft dephaser solenoid programming RENAULT_IN_CAM_DEPHASER_SOL_PROG
- Request
22 22 41 - Service 22
DID 2241 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1990 to 2026.
Inlet camshaft dephasing RENAULT_IN_CAM_DEPHASING
- Request
22 20 31 - Service 22
DID 2031 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 50)- Range
- 0 to 1310.7 °
- Unit
- °
In testing for 1990 to 2026.
Intake air temperature IATSAE J1979Confirmed
- Request
01 0F - Service 01
PID 0F - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2017, 2021, 2023. Supported for 2010, 2016, 2018 to 2020, 2024.
Intake air temperature, bank 1, sensor 1 IAT_11SAE J1979Confirmed
- Request
01 68 - Service 01
PID 68 - Module
7E0 → 7E8 - Every
250 ms
Bits 8 to 15 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2021, 2023. Supported for 2019 to 2020, 2024.
Intake air temperature, bank 1, sensor 2 IAT_12SAE J1979Confirmed
- Request
01 68 - Service 01
PID 68 - Module
7E0 → 7E8 - Every
250 ms
Bits 16 to 23 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2021, 2023. Supported for 2019 to 2020, 2024.
Intake air temperature, bank 1, sensor 3 IAT_13SAE J1979Confirmed
- Request
01 68 - Service 01
PID 68 - Module
7E0 → 7E8 - Every
250 ms
Bits 24 to 31 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2021. Supported for 2019 to 2020, 2023 to 2024.
Intake air temperature, bank 2, sensor 1 IAT_21SAE J1979Confirmed
- Request
01 68 - Service 01
PID 68 - Module
7E0 → 7E8 - Every
250 ms
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2021. Supported for 2019 to 2020, 2023 to 2024.
Intake air temperature, bank 2, sensor 2 IAT_22SAE J1979Confirmed
- Request
01 68 - Service 01
PID 68 - Module
7E0 → 7E8 - Every
250 ms
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2021. Supported for 2019 to 2020, 2023 to 2024.
Intake air temperature, bank 2, sensor 3 IAT_23SAE J1979Confirmed
- Request
01 68 - Service 01
PID 68 - Module
7E0 → 7E8 - Every
250 ms
Bits 48 to 55 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2021. Supported for 2019 to 2020, 2023 to 2024.
Intake manifold absolute pressure MAPSAE J1979Confirmed
- Request
01 0B - Service 01
PID 0B - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 kPa
- Unit
- kPa
Confirmed for 2017, 2021, 2023. Supported for 2010, 2016, 2018 to 2020, 2024.
Internal fault code RENAULT_INT_FAULT_CODE
- Request
22 30 2D - Service 22
DID 302D - Module
748 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
val- Range
- 0 to 4294967295
- Unit
- Number
In testing for 1990 to 2026.
Knock signal, average RENAULT_KNOCK_AVG
- Request
22 28 4D - Service 22
DID 284D - Module
7E0 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1990 to 2026.
Long term fuel trim (bank 1) LONGFT1SAE J1979Confirmed
- Request
01 07 - Service 01
PID 07 - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 128 − 100)- Range
- -100 to 99.2 %
- Unit
- %
Confirmed for 2017, 2021, 2023. Supported for 2010, 2018 to 2020, 2024.
LPG pressure RENAULT_LPG_P
- Request
22 F4 23 - Service 22
DID F423 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 bar
- Unit
- bar
In testing for 1990 to 2026.
Manifold pressure RENAULT_MANIFOLD_P
- Request
22 24 0B - Service 22
DID 240B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 kPa
- Unit
- kPa
In testing for 1990 to 2026.
Manifold pressure sensor voltage RENAULT_MANIFOLD_P_SNS_V
- Request
22 FD 81 - Service 22
DID FD81 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.99975 V
- Unit
- V
In testing for 1990 to 2026.
Manifold pressure, linearised RENAULT_MANIFOLD_P_LIN
- Request
22 24 D7 - Service 22
DID 24D7 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Raw value
In testing for 1990 to 2026.
Measured air flow RENAULT_MAF
Pelican can show this parameter as the mass air flow.
- Request
22 24 F2 - Service 22
DID 24F2 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 g/s
- Unit
- g/s
In testing for 1990 to 2026.
Misfire counter, total RENAULT_MISFIRE_CNT
- Request
22 28 74 - Service 22
DID 2874 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 1990 to 2026.
Motor status RENAULT_MOTOR
- Request
22 20 10 - Service 22
DID 2010 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1990 to 2026.
Motor status RENAULT_MOTOR_STS_TC
- Request
22 30 0D - Service 22
DID 300D - Module
748 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1990 to 2026.
O2 sensor heating delay, upstream RENAULT_O2_UP_HEAT_DELAY
- Request
22 24 C4 - Service 22
DID 24C4 - Module
7E0 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 1990 to 2026.
O2 sensor heating resistance, downstream RENAULT_O2_DN_HEAT_R
- Request
22 24 4C - Service 22
DID 244C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 Ω
- Unit
- Ω
In testing for 1990 to 2026.
O2 sensor heating resistance, upstream RENAULT_O2_UP_HEAT_R
- Request
22 24 4B - Service 22
DID 244B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 Ω
- Unit
- Ω
In testing for 1990 to 2026.
O2 sensor voltage, downstream RENAULT_O2_DN_V
- Request
22 24 4A - Service 22
DID 244A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 1990 to 2026.
O2 sensor voltage, upstream RENAULT_O2_UP_V
- Request
22 24 49 - Service 22
DID 2449 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 1990 to 2026.
Parking brake RENAULT_PARK_BRAKE
- Request
22 4B 27 - Service 22
DID 4B27 - Module
740 → 760 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1990 to 2026.
Post-ignition status RENAULT_ECU_POST_IGN
- Request
22 20 0E - Service 22
DID 200E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1990 to 2026.
Power take off (PTO) status PTO_STATSAE J1979Confirmed
- Request
01 1E - Service 01
PID 1E - Module
7E0 → 7E8 - Every
1 s
Bit 7 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
Confirmed for 2021. Supported for 2016, 2019 to 2020, 2024.
Pressure sensor offset RENAULT_P_SNS_OFFSET
- Request
22 4B 39 - Service 22
DID 4B39 - Module
740 → 760 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 bar
- Unit
- bar
In testing for 1990 to 2026.
Relative Throttle A Position TP_A_RELSAE J1979Confirmed
- Request
01 6C - Service 01
PID 6C - Module
7E0 → 7E8 - Every
250 ms
Bits 16 to 23 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2021. Supported for 2019 to 2020, 2024.
Relative Throttle B Position TP_B_RELSAE J1979Confirmed
- Request
01 6C - Service 01
PID 6C - Module
7E0 → 7E8 - Every
250 ms
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2021. Supported for 2019 to 2020, 2024.
Richness correction RENAULT_RICHNESS_CORR
- Request
22 28 4E - Service 22
DID 284E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1990 to 2026.
Richness correction, operating RENAULT_RICHNESS_CORR_OP
- Request
22 28 50 - Service 22
DID 2850 - Module
7E0 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 %
- Unit
- %
In testing for 1990 to 2026.
Richness regulation gain RENAULT_RICHNESS_REG_GAIN
- Request
22 28 51 - Service 22
DID 2851 - Module
7E0 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1990 to 2026.
Richness regulation offset RENAULT_RICHNESS_REG_OFFSET
- Request
22 28 52 - Service 22
DID 2852 - Module
7E0 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 255 ms
- Unit
- ms
In testing for 1990 to 2026.
Richness, adaptive operating RENAULT_RICHNESS_ADAPT
- Request
22 28 73 - Service 22
DID 2873 - Module
7E0 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 1990 to 2026.
Short term fuel trim (bank 1) SHRTFT1SAE J1979Confirmed
Correction being used by the closed-loop fuel algorithm.
Pelican can show this parameter as the short term fuel trim.
- Request
01 06 - Service 01
PID 06 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 128 − 100)- Range
- -100 to 99.2 %
- Unit
- %
Confirmed for 2017, 2020 to 2021, 2023 to 2024. Supported for 2010, 2018 to 2019.
Short term secondary O2 sensor fuel trim (bank 1) STSO2FT1SAE J1979Confirmed
- Request
01 55 - Service 01
PID 55 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 128 − 100)- Range
- -100 to 99.22 %
- Unit
- %
Confirmed for 2021. Supported for 2019 to 2020, 2024.
Test result 1 RENAULT_TEST_RESULT_1
- Request
22 24 93 - Service 22
DID 2493 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1990 to 2026.
Test result 2 RENAULT_TEST_RESULT_2
- Request
22 24 94 - Service 22
DID 2494 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1990 to 2026.
Throttle limits programming RENAULT_THROTTLE_LIMITS_PROG
- Request
22 24 5D - Service 22
DID 245D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1990 to 2026.
Throttle low stop, programmed RENAULT_THROTTLE_LOW_STOP_PROG
- Request
22 24 57 - Service 22
DID 2457 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 20)- Range
- 0 to 3276.75 %
- Unit
- %
In testing for 1990 to 2026.
Throttle position, measured RENAULT_THROTTLE_POS
- Request
22 24 2F - Service 22
DID 242F - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 20)- Range
- 0 to 3276.75 %
- Unit
- %
In testing for 1990 to 2026.
Throttle position, reference RENAULT_THROTTLE_POS_REF
- Request
22 24 14 - Service 22
DID 2414 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 20)- Range
- 0 to 3276.75 %
- Unit
- %
In testing for 1990 to 2026.
Throttle position, track 1 RENAULT_THROTTLE_POS_1
- Request
22 24 15 - Service 22
DID 2415 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 20)- Range
- 0 to 3276.75 %
- Unit
- %
In testing for 1990 to 2026.
Throttle position, track 2 RENAULT_THROTTLE_POS_2
- Request
22 24 16 - Service 22
DID 2416 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 20)- Range
- 0 to 3276.75 %
- Unit
- %
In testing for 1990 to 2026.
Throttle safe mode value, programmed RENAULT_THROTTLE_SAFE_MODE_PROG
- Request
22 24 C9 - Service 22
DID 24C9 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 20)- Range
- 0 to 3276.75 %
- Unit
- %
In testing for 1990 to 2026.
Throttle voltage, track 1 RENAULT_THROTTLE_V1
- Request
22 24 18 - Service 22
DID 2418 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2026.
Throttle voltage, track 2 RENAULT_THROTTLE_V2
- Request
22 24 19 - Service 22
DID 2419 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2026.
Timing advance SPARKADVSAE J1979Confirmed
Ignition timing spark advance for the first cylinder. Measured in degrees before dead center. Minus is degrees before dead center, positive is degrees after.
- Request
01 0E - Service 01
PID 0E - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 2 − 64)- Range
- -64 to 63.5 °
- Unit
- °
Confirmed for 2017, 2021, 2023. Supported for 2010, 2018 to 2020, 2024.
Top dead center sensor signal RENAULT_TDC_SNS_SIG
- Request
22 21 61 - Service 22
DID 2161 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1990 to 2026.
Torque setpoint programming RENAULT_TORQUE_SETPT_PROG
- Request
22 30 11 - Service 22
DID 3011 - Module
748 - Every
1 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1990 to 2026.
Torque, applied RENAULT_TORQUE_APPLIED
- Request
22 30 2C - Service 22
DID 302C - Module
748 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 10)- Range
- 0 to 2550 N·m
- Unit
- N·m
In testing for 1990 to 2026.
Torque, requested RENAULT_TORQUE_REQ
- Request
22 30 25 - Service 22
DID 3025 - Module
748 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 N·m
- Unit
- N·m
In testing for 1990 to 2026.
Torquemeter correction, adaptive RENAULT_TORQUEMETER_ADAPT_CORR
- Request
22 21 5D - Service 22
DID 215D - Module
7E0 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val − 32768)- Range
- -32768 to 32767
- Unit
- Number
In testing for 1990 to 2026.
Torquemeter value, programmed RENAULT_TORQUEMETER_PROG
- Request
22 21 56 - Service 22
DID 2156 - Module
7E0 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1990 to 2026.
Traction control RENAULT_TC
- Request
22 4B 35 - Service 22
DID 4B35 - Module
740 → 760 - Every
1 s - Testing
Bit 6 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2026.
Traction control, deactivated RENAULT_TC_OFF
- Request
22 4B 35 - Service 22
DID 4B35 - Module
740 → 760 - Every
1 s - Testing
Bit 4 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2026.
Traction control, warning RENAULT_TC_WARN
- Request
22 4B 35 - Service 22
DID 4B35 - Module
740 → 760 - Every
1 s - Testing
Bit 7 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2026.
Trailer stability RENAULT_TRAILER_STAB
- Request
22 4B 2E - Service 22
DID 4B2E - Module
740 → 760 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1990 to 2026.
Trajectory control RENAULT_TRAJ_CTRL
- Request
22 4B 35 - Service 22
DID 4B35 - Module
740 → 760 - Every
1 s - Testing
Bit 10 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2026.
Trajectory control, warning RENAULT_TRAJ_CTRL_WARN
- Request
22 4B 35 - Service 22
DID 4B35 - Module
740 → 760 - Every
1 s - Testing
Bit 11 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2026.
Type of fuel currently being used by the vehicle FUEL_TYPSAE J1979Confirmed
- Request
01 51 - Service 01
PID 51 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
1 | GAS | Gasoline/petrol |
2 | METH | Methanol |
3 | ETH | Ethanol |
4 | DSL | Diesel |
5 | LPG | Liquefied petroleum gas |
6 | CNG | Compressed natural gas |
7 | PROP | Propane |
8 | ELEC | Battery/electric |
9 | BI_GAS | Bi-fuel vehicle using gasoline/petrol |
10 | BI_METH | Bi-fuel vehicle using methanol |
11 | BI_ETH | Bi-fuel vehicle using ethanol |
12 | BI_LPG | Bi-fuel vehicle using LPG |
13 | BI_CNG | Bi-fuel vehicle using CNG |
14 | BI_PROP | Bi-fuel vehicle using propane |
15 | BI_ELEC | Bi-fuel vehicle using battery |
16 | BI_MIX | Bi-fuel vehicle using battery and combustion engine for propulsion |
17 | HYB_GAS | Hybrid vehicle using gasoline engine for propulsion |
18 | HYB_ETH | Hybrid vehicle using gasoline engine on ethanol for propulsion |
19 | HYB_DSL | Hybrid vehicle using diesel engine for propulsion |
20 | HYB_ELEC | Hybrid vehicle using battery for propulsion |
21 | HYB_MIX | Hybrid vehicle using battery and combustion engine for propulsion |
22 | HYB_REG | Hybrid vehicle in regeneration mode |
23 | BI_DSL | Bi-fuel vehicle using diesel |
24 | BI_NG | Bi-fuel vehicle using natural gas |
25 | BI_DSL | Bi-fuel vehicle using diesel |
26 | NG | Natural gas |
27 | DSL_CNG | Dual fuel vehicle using diesel and CNG |
28 | DSL_LNG | Dual fuel vehicle using diesel and LNG |
29 | FC_H2 | Fuel cell utilizing hydrogen |
30 | HICE_HHO | Hydrogen Internal Combustion Engine |
31 | KERO | Kerosene |
32 | HFO | Heavy Fuel Oil |
Confirmed for 2021, 2023. Supported for 2019 to 2020, 2024.
Vacuum sensor pressure RENAULT_VACUUM_P
- Request
22 4B 4E - Service 22
DID 4B4E - Module
740 → 760 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 bar
- Unit
- bar
In testing for 1990 to 2026.
Vehicle status RENAULT_VEH
- Request
22 4B 1A - Service 22
DID 4B1A - Module
740 → 760 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1990 to 2026.
Warning light RENAULT_WARNING_LIGHT
- Request
22 30 24 - Service 22
DID 3024 - Module
748 - Every
1 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1990 to 2026.
Wastegate A position WG_A_ACTSAE J1979Confirmed
If an on/off solenoid is used, is 0% when the wastegate is commanded off (allow full boost), 100% when commanded on (dump boost). If a vacuum solenoid is duty cycled, the duty cycle from 0 to 100% is displayed. If a linear or stepper motor valve is used, the fully closed position (full boost) is displayed as 0%, the fully open position (dump boost) is displayed as 100%. Intermediate positions are displayed as a percent of the full-open position. Any other actuation method is normalized to display 0% when the WG is commanded off and 100% when the WG is commanded on.
- Request
01 72 - Service 01
PID 72 - Module
7E0 → 7E8 - Every
250 ms
Bits 16 to 23 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2021. Supported for 2019 to 2020, 2024.
Wastegate B position WG_B_ACTSAE J1979Confirmed
If an on/off solenoid is used, is 0% when the wastegate is commanded off (allow full boost), 100% when commanded on (dump boost). If a vacuum solenoid is duty cycled, the duty cycle from 0 to 100% is displayed. If a linear or stepper motor valve is used, the fully closed position (full boost) is displayed as 0%, the fully open position (dump boost) is displayed as 100%. Intermediate positions are displayed as a percent of the full-open position. Any other actuation method is normalized to display 0% when the WG is commanded off and 100% when the WG is commanded on.
- Request
01 72 - Service 01
PID 72 - Module
7E0 → 7E8 - Every
250 ms
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2021. Supported for 2019 to 2020, 2024.
Engine › Internal
Boost bressure A control status BP_ASAE J1979Confirmed
- Request
01 70 - Service 01
PID 70 - Module
7E0 → 7E8 - Every
250 ms
Bits 78 to 79 of the reply, 2 bits.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
1 | BP_A_OL | Open loop |
2 | BP_A_CL | Closed loop |
3 | BP_A_FAULT | Fault |
Confirmed for 2021. Supported for 2019 to 2020, 2024.
Boost pressure A control status supported BP_A_SUPSAE J1979Confirmed
- Request
01 70 - Service 01
PID 70 - Module
7E0 → 7E8 - Every
250 ms
Bit 5 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2021. Supported for 2019 to 2020, 2024.
Boost pressure A supported BP_A_ACT_SUPSAE J1979Confirmed
- Request
01 70 - Service 01
PID 70 - Module
7E0 → 7E8 - Every
250 ms
Bit 6 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2021. Supported for 2019 to 2020, 2024.
Boost pressure B control status supported BP_B_SUPSAE J1979Confirmed
- Request
01 70 - Service 01
PID 70 - Module
7E0 → 7E8 - Every
250 ms
Bit 2 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2021. Supported for 2019 to 2020, 2024.
Boost pressure B supported BP_B_ACT_SUPSAE J1979Confirmed
- Request
01 70 - Service 01
PID 70 - Module
7E0 → 7E8 - Every
250 ms
Bit 3 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2021. Supported for 2019 to 2020, 2024.
Commanded boost pressure A supported BP_A_CMD_SUPSAE J1979Confirmed
- Request
01 70 - Service 01
PID 70 - Module
7E0 → 7E8 - Every
250 ms
Bit 7 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2021. Supported for 2019 to 2020, 2024.
Commanded boost pressure B supported BP_B_CMD_SUPSAE J1979Confirmed
- Request
01 70 - Service 01
PID 70 - Module
7E0 → 7E8 - Every
250 ms
Bit 4 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2021. Supported for 2019 to 2020, 2024.
Commanded Throttle Actuator A Control supported? CTAC_A_SUPSAE J1979Confirmed
- Request
01 6C - Service 01
PID 6C - Module
7E0 → 7E8 - Every
250 ms
Bit 7 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2021. Supported for 2019 to 2020, 2024.
Commanded Throttle Actuator B Control supported? CTAC_B_SUPSAE J1979Confirmed
- Request
01 6C - Service 01
PID 6C - Module
7E0 → 7E8 - Every
250 ms
Bit 5 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2021. Supported for 2019 to 2020, 2024.
Commanded wastegate A position supported WG_A_CMD_SUPSAE J1979Confirmed
- Request
01 72 - Service 01
PID 72 - Module
7E0 → 7E8 - Every
250 ms
Bit 7 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2021. Supported for 2019 to 2020, 2024.
Commanded wastegate B position supported WG_B_CMD_SUPSAE J1979Confirmed
- Request
01 72 - Service 01
PID 72 - Module
7E0 → 7E8 - Every
250 ms
Bit 5 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2021. Supported for 2019 to 2020, 2024.
IAT Bank 1, Sensor 1 supported IAT_11_SUPSAE J1979Confirmed
- Request
01 68 - Service 01
PID 68 - Module
7E0 → 7E8 - Every
250 ms
Bit 7 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2021, 2023. Supported for 2019 to 2020, 2024.
IAT Bank 1, Sensor 1 supported IAT_21_SUPSAE J1979Confirmed
- Request
01 68 - Service 01
PID 68 - Module
7E0 → 7E8 - Every
250 ms
Bit 4 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2021, 2023. Supported for 2019 to 2020, 2024.
IAT Bank 1, Sensor 2 supported IAT_12_SUPSAE J1979Confirmed
- Request
01 68 - Service 01
PID 68 - Module
7E0 → 7E8 - Every
250 ms
Bit 6 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2021, 2023. Supported for 2019 to 2020, 2024.
IAT Bank 1, Sensor 3 supported IAT_13_SUPSAE J1979Confirmed
- Request
01 68 - Service 01
PID 68 - Module
7E0 → 7E8 - Every
250 ms
Bit 5 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2021, 2023. Supported for 2019 to 2020, 2024.
IAT Bank 2, Sensor 2 supported IAT_22_SUPSAE J1979Confirmed
- Request
01 68 - Service 01
PID 68 - Module
7E0 → 7E8 - Every
250 ms
Bit 3 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2021, 2023. Supported for 2019 to 2020, 2024.
IAT Bank 2, Sensor 3 supported IAT_23_SUPSAE J1979Confirmed
- Request
01 68 - Service 01
PID 68 - Module
7E0 → 7E8 - Every
250 ms
Bit 2 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2021, 2023. Supported for 2019 to 2020, 2024.
Is ECT sensor 1 supported? ECT_1_SUPSAE J1979Confirmed
- Request
01 67 - Service 01
PID 67 - Module
7E0 → 7E8 - Every
1 s
Bit 7 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
Confirmed for 2021, 2023. Supported for 2019 to 2020, 2024.
Is ECT sensor 2 supported? ECT_2_SUPSAE J1979Confirmed
- Request
01 67 - Service 01
PID 67 - Module
7E0 → 7E8 - Every
1 s
Bit 6 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
Confirmed for 2021, 2023. Supported for 2019 to 2020, 2024.
Relative Throttle A Position data supported? RTP_A_SUPSAE J1979Confirmed
- Request
01 6C - Service 01
PID 6C - Module
7E0 → 7E8 - Every
250 ms
Bit 6 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2021. Supported for 2019 to 2020, 2024.
Relative Throttle B Position data supported? RTP_B_SUPSAE J1979Confirmed
- Request
01 6C - Service 01
PID 6C - Module
7E0 → 7E8 - Every
250 ms
Bit 4 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2021. Supported for 2019 to 2020, 2024.
Wastegate A position supported WG_A_ACT_SUPSAE J1979Confirmed
- Request
01 72 - Service 01
PID 72 - Module
7E0 → 7E8 - Every
250 ms
Bit 6 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2021. Supported for 2019 to 2020, 2024.
Wastegate B position supported WG_B_ACT_SUPSAE J1979Confirmed
- Request
01 72 - Service 01
PID 72 - Module
7E0 → 7E8 - Every
250 ms
Bit 4 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2021. Supported for 2019 to 2020, 2024.
Engine › OxygenSensors
02S Bank 1, Sensor 1 present O2S11_EXISTSSAE J1979Confirmed
- Request
01 13 - Service 01
PID 13 - Module
7E0 → 7E8 - Every
3600 s
Bit 7 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2017. Supported for 2010, 2016, 2018 to 2021, 2023 to 2024.
02S Bank 1, Sensor 2 present O2S12_EXISTSSAE J1979Confirmed
- Request
01 13 - Service 01
PID 13 - Module
7E0 → 7E8 - Every
3600 s
Bit 6 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2017. Supported for 2010, 2016, 2018 to 2021, 2023 to 2024.
02S Bank 1, Sensor 3 present O2S13_EXISTSSAE J1979Confirmed
- Request
01 13 - Service 01
PID 13 - Module
7E0 → 7E8 - Every
3600 s
Bit 5 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2017. Supported for 2010, 2016, 2018 to 2021, 2023 to 2024.
02S Bank 1, Sensor 4 present O2S14_EXISTSSAE J1979Confirmed
- Request
01 13 - Service 01
PID 13 - Module
7E0 → 7E8 - Every
3600 s
Bit 4 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2017. Supported for 2010, 2016, 2018 to 2021, 2023 to 2024.
02S Bank 2, Sensor 1 present O2S21_EXISTSSAE J1979Confirmed
- Request
01 13 - Service 01
PID 13 - Module
7E0 → 7E8 - Every
3600 s
Bit 3 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2017. Supported for 2010, 2016, 2018 to 2021, 2023 to 2024.
02S Bank 2, Sensor 2 present O2S22_EXISTSSAE J1979Confirmed
- Request
01 13 - Service 01
PID 13 - Module
7E0 → 7E8 - Every
3600 s
Bit 2 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2017. Supported for 2010, 2016, 2018 to 2021, 2023 to 2024.
02S Bank 2, Sensor 3 present O2S23_EXISTSSAE J1979Confirmed
- Request
01 13 - Service 01
PID 13 - Module
7E0 → 7E8 - Every
3600 s
Bit 1 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2017. Supported for 2010, 2016, 2018 to 2021, 2023 to 2024.
02S Bank 2, Sensor 4 present O2S24_EXISTSSAE J1979Confirmed
- Request
01 13 - Service 01
PID 13 - Module
7E0 → 7E8 - Every
3600 s
Bit 0 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2017. Supported for 2010, 2016, 2018 to 2021, 2023 to 2024.
Lambda value, Equivalence Ratio Bank 1, Sensor 1 LAMBDA11_VOLTSAE J1979Confirmed
Pelican can show this parameter as the O2 lambda.
- Request
01 24 - Service 01
PID 24 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 32768)- Range
- 0 to 1.99
- Unit
- Number
Confirmed for 2020 to 2021, 2023 to 2024. Supported for 2016 to 2019.
Wide Range O2S Voltage, O2 Sensor Bank 1, Sensor 1 O2S11_VOLTSAE J1979Confirmed
- Request
01 24 - Service 01
PID 24 - Module
7E0 → 7E8 - Every
250 ms
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val ÷ 8196)- Range
- 0 to 7.999 V
- Unit
- V
Confirmed for 2020 to 2021, 2023 to 2024. Supported for 2016 to 2019.