AC charging power available RENAULT_AC_P_AVAIL
- Request
22 30 0F - Service 22
DID 300F - Module
DADA → DA - Every
2 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 40)- Range
- 0 to 1638.375 kW
- Unit
- kW
In testing for 1990 to 2026.
AC mains current RENAULT_AC_A
- Request
22 30 0D - Service 22
DID 300D - Module
DADA → DA - Every
2 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 A
- Unit
- A
In testing for 1990 to 2026.
AC mains phases RENAULT_AC_PHASES
- Request
22 30 0B - Service 22
DID 300B - Module
DADA → DA - Every
2 s - Testing
Bits 4 to 7 of the reply, 4 bits.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
0 | ONE | One phase |
1 | TWO | Two phase |
2 | THREE | Three phase |
3 | NONE | Not detected |
In testing for 1990 to 2026.
AC mains voltage RENAULT_AC_V
- Request
22 2B 8A - Service 22
DID 2B8A - Module
DADA → DA - Every
2 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 2)- Range
- 0 to 32767.5 V
- Unit
- V
In testing for 1990 to 2026.
Battery module 1 temperature RENAULT_MOD_T1
- Request
21 04 - Service 21
PID 04 - Module
79B → 7BB - Every
60 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 1990 to 2026.
Battery module 2 temperature RENAULT_MOD_T2
- Request
21 04 - Service 21
PID 04 - Module
79B → 7BB - Every
60 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 1990 to 2026.
Battery module 3 temperature RENAULT_MOD_T3
- Request
21 04 - Service 21
PID 04 - Module
79B → 7BB - Every
60 s - Testing
Bits 64 to 71 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 1990 to 2026.
Battery module 4 temperature RENAULT_MOD_T4
- Request
21 04 - Service 21
PID 04 - Module
79B → 7BB - Every
60 s - Testing
Bits 88 to 95 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 1990 to 2026.
Battery module 5 temperature RENAULT_MOD_T5
- Request
21 04 - Service 21
PID 04 - Module
79B → 7BB - Every
60 s - Testing
Bits 112 to 119 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 1990 to 2026.
Battery module 6 temperature RENAULT_MOD_T6
- Request
21 04 - Service 21
PID 04 - Module
79B → 7BB - Every
60 s - Testing
Bits 136 to 143 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 1990 to 2026.
Battery module 7 temperature RENAULT_MOD_T7
- Request
21 04 - Service 21
PID 04 - Module
79B → 7BB - Every
60 s - Testing
Bits 160 to 167 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 1990 to 2026.
Battery module 8 temperature RENAULT_MOD_T8
- Request
21 04 - Service 21
PID 04 - Module
79B → 7BB - Every
60 s - Testing
Bits 184 to 191 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 1990 to 2026.
Battery module 9 temperature RENAULT_MOD_T9
- Request
21 04 - Service 21
PID 04 - Module
79B → 7BB - Every
60 s - Testing
Bits 208 to 215 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 1990 to 2026.
Battery module 10 temperature RENAULT_MOD_T10
- Request
21 04 - Service 21
PID 04 - Module
79B → 7BB - Every
60 s - Testing
Bits 232 to 239 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 1990 to 2026.
Battery module 11 temperature RENAULT_MOD_T11
- Request
21 04 - Service 21
PID 04 - Module
79B → 7BB - Every
60 s - Testing
Bits 256 to 263 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 1990 to 2026.
Battery module 12 temperature RENAULT_MOD_T12
- Request
21 04 - Service 21
PID 04 - Module
79B → 7BB - Every
60 s - Testing
Bits 280 to 287 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 1990 to 2026.
Battery voltage, 12V RENAULT_12V_BAT_V
Pelican can show this parameter as the starter battery voltage.
- Request
22 30 01 - Service 22
DID 3001 - Module
748 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 10)- Range
- 0 to 25.5 V
- Unit
- V
In testing for 1990 to 2026.
Charge plug present RENAULT_PLUG
Pelican can show this parameter as the plug state.
- Request
22 2B 85 - Service 22
DID 2B85 - Module
DADA → DA - Every
2 s - Testing
Bits 4 to 7 of the reply, 4 bits.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
In testing for 1990 to 2026.
Charge state RENAULT_CHG_STATE
- Request
22 2B 6D - Service 22
DID 2B6D - Module
DADA → DA - Every
2 s - Testing
Bits 4 to 7 of the reply, 4 bits.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
0 | STOPPED | Stopped |
1 | TIMER_WAIT | Waiting for timer |
2 | DONE | Done |
3 | CHARGING | Battery |
4 | INTERRUPTED | Interrupted |
5 | POWER_WAIT | Waiting for power |
6 | FLAP_OPEN | Charge flap open |
8 | PREPARING | Preparing |
In testing for 1990 to 2026.
Charge type RENAULT_CHG_TYPE
- Request
22 2B 7A - Service 22
DID 2B7A - Module
DADA → DA - Every
2 s - Testing
Bits 4 to 7 of the reply, 4 bits.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
0 | UNDEFINED | Undefined |
1 | TYPE2 | Type 2 |
2 | TYPE2 | Type 2 |
3 | CHADEMO | CHAdeMO |
4 | CCS |
In testing for 1990 to 2026.
Complete charge cycles RENAULT_CYCLES
- Request
22 92 10 - Service 22
DID 9210 - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 1990 to 2026.
Computer supply voltage RENAULT_ECU_V
- Request
22 01 2F - Service 22
DID 012F - Module
740 → 760 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 V
- Unit
- V
In testing for 1990 to 2026.
Control module voltage VPWRSAE J1979Confirmed
Power input to the OBD control module. VPWR is normally battery voltage, less any voltage drop in the circuit between the battery and the control module.
Pelican can show this parameter as the starter battery voltage.
- Request
01 42 - Service 01
PID 42 - Module
7E0 → 7E8 - Every
10 s
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65535 V
- Unit
- V
Confirmed for 2019, 2023. Supported for 2016 to 2018, 2020 to 2021, 2024.
Energy charged, total RENAULT_E_CHG
- Request
22 92 43 - Service 22
DID 9243 - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 4294967.295 kWh
- Unit
- kWh
In testing for 1990 to 2026.
Energy discharged, total RENAULT_E_DISCHG
- Request
22 92 45 - Service 22
DID 9245 - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 4294967.295 kWh
- Unit
- kWh
In testing for 1990 to 2026.
Energy regenerated, total RENAULT_E_REGEN
- Request
22 92 47 - Service 22
DID 9247 - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 4294967.295 kWh
- Unit
- kWh
In testing for 1990 to 2026.
High voltage battery available energy RENAULT_HV_E_AVAIL
- Request
22 91 C8 - Service 22
DID 91C8 - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 23 of the reply, 24 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 16777.215 kWh
- Unit
- kWh
In testing for 1990 to 2026.
High voltage battery average temperature RENAULT_HV_T
- Request
22 90 12 - Service 22
DID 9012 - Module
DADB → DB - Every
10 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 16 − 40)- Range
- -40 to 4055.9375 °C
- Unit
- °C
In testing for 1990 to 2026.
High voltage battery current RENAULT_HV_A
Pelican can show this parameter as the traction battery current.
- Request
22 92 5D - Service 22
DID 925D - Module
DADB → DB - Every
2 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × -1 ÷ 32 + 1020)- Range
- -1027.97 to 1020 A
- Unit
- A
In testing for 1990 to 2026.
High voltage battery current RENAULT_HV_A_3042
- Request
22 30 42 - Service 22
DID 3042 - Module
DADA → DA - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 2 − 16383.75)- Range
- -16383.75 to 16383.75 A
- Unit
- A
In testing for 1990 to 2026.
High voltage battery current, power electronics RENAULT_HV_A_PEB
- Request
22 32 04 - Service 22
DID 3204 - Module
7E4 → 7EC - Every
2 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4 − 8192)- Range
- -8192 to 8191.75 A
- Unit
- A
In testing for 1990 to 2026.
High voltage battery current, vehicle controller RENAULT_HV_A_EVC
- Request
22 21 CC - Service 22
DID 21CC - Module
DADA → DA - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4 − 500)- Range
- -500 to 15883.75 A
- Unit
- A
In testing for 1990 to 2026.
High voltage battery voltage RENAULT_HV_V
Pelican can show this parameter as the traction battery voltage.
- Request
22 90 05 - Service 22
DID 9005 - Module
DADB → DB - Every
2 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 V
- Unit
- V
In testing for 1990 to 2026.
High voltage battery voltage, power electronics RENAULT_HV_V_PEB
- Request
22 32 03 - Service 22
DID 3203 - Module
7E4 → 7EC - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 2)- Range
- 0 to 32767.5 V
- Unit
- V
In testing for 1990 to 2026.
High voltage battery voltage, vehicle controller RENAULT_HV_V_EVC
- Request
22 20 FE - Service 22
DID 20FE - Module
DADA → DA - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 V
- Unit
- V
In testing for 1990 to 2026.
Hybrid battery pack remaining charge BAT_SOCSAE J1979Confirmed
The percent remaining level of charge for a battery pack used for propulsion, expressed as a percentage of total useable battery energy, commonly referred to as State Of Charge (SOC).
Pelican can show this parameter as the state of charge.
- Request
01 5B - Service 01
PID 5B - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2023.
Maximum charge power RENAULT_CHG_P_MAX
- Request
22 90 18 - Service 22
DID 9018 - Module
DADB → DB - Every
10 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655.35 kW
- Unit
- kW
In testing for 1990 to 2026.
Pack temperature 1 RENAULT_PACK_T1
- Request
22 91 31 - Service 22
DID 9131 - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 16 − 40)- Range
- -40 to 4055.9375 °C
- Unit
- °C
In testing for 1990 to 2026.
Pack temperature 2 RENAULT_PACK_T2
- Request
22 91 32 - Service 22
DID 9132 - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 16 − 40)- Range
- -40 to 4055.9375 °C
- Unit
- °C
In testing for 1990 to 2026.
Pack temperature 3 RENAULT_PACK_T3
- Request
22 91 33 - Service 22
DID 9133 - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 16 − 40)- Range
- -40 to 4055.9375 °C
- Unit
- °C
In testing for 1990 to 2026.
Pack temperature 4 RENAULT_PACK_T4
- Request
22 91 34 - Service 22
DID 9134 - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 16 − 40)- Range
- -40 to 4055.9375 °C
- Unit
- °C
In testing for 1990 to 2026.
Pack temperature 5 RENAULT_PACK_T5
- Request
22 91 35 - Service 22
DID 9135 - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 16 − 40)- Range
- -40 to 4055.9375 °C
- Unit
- °C
In testing for 1990 to 2026.
Pack temperature 6 RENAULT_PACK_T6
- Request
22 91 36 - Service 22
DID 9136 - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 16 − 40)- Range
- -40 to 4055.9375 °C
- Unit
- °C
In testing for 1990 to 2026.
Pack temperature 7 RENAULT_PACK_T7
- Request
22 91 37 - Service 22
DID 9137 - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 16 − 40)- Range
- -40 to 4055.9375 °C
- Unit
- °C
In testing for 1990 to 2026.
Pack temperature 8 RENAULT_PACK_T8
- Request
22 91 38 - Service 22
DID 9138 - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 16 − 40)- Range
- -40 to 4055.9375 °C
- Unit
- °C
In testing for 1990 to 2026.
Pack temperature 9 RENAULT_PACK_T9
- Request
22 91 39 - Service 22
DID 9139 - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 16 − 40)- Range
- -40 to 4055.9375 °C
- Unit
- °C
In testing for 1990 to 2026.
Pack temperature 10 RENAULT_PACK_T10
- Request
22 91 3A - Service 22
DID 913A - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 16 − 40)- Range
- -40 to 4055.9375 °C
- Unit
- °C
In testing for 1990 to 2026.
Pack temperature 11 RENAULT_PACK_T11
- Request
22 91 3B - Service 22
DID 913B - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 16 − 40)- Range
- -40 to 4055.9375 °C
- Unit
- °C
In testing for 1990 to 2026.
Pack temperature 12 RENAULT_PACK_T12
- Request
22 91 3C - Service 22
DID 913C - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 16 − 40)- Range
- -40 to 4055.9375 °C
- Unit
- °C
In testing for 1990 to 2026.
State of charge RENAULT_SOC
Pelican can show this parameter as the state of charge.
- Request
22 90 02 - Service 22
DID 9002 - Module
DADB → DB - Every
10 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 100 %
- Unit
- %
In testing for 1990 to 2026.
State of charge RENAULT_SOC_9002
- Request
22 90 02 - Service 22
DID 9002 - Module
DADA → DA - Every
10 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655.35 %
- Unit
- %
In testing for 1990 to 2026.
State of charge, battery controller RENAULT_SOC_9001
- Request
22 90 01 - Service 22
DID 9001 - Module
DADB → DB - Every
10 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655.35 %
- Unit
- %
In testing for 1990 to 2026.
State of charge, vehicle controller RENAULT_SOC_EVC
- Request
22 20 02 - Service 22
DID 2002 - Module
DADA → DA - Every
10 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 50)- Range
- 0 to 1310.7 %
- Unit
- %
In testing for 1990 to 2026.
State of health RENAULT_SOH
Pelican can show this parameter as the state of health.
- Request
22 90 03 - Service 22
DID 9003 - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655.35 %
- Unit
- %
In testing for 1990 to 2026.
Supply voltage, ECU RENAULT_ECU_SUPPLY_V
- Request
22 20 05 - Service 22
DID 2005 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655.35 V
- Unit
- V
In testing for 1990 to 2026.
Battery › Cells
Cell 1 voltage RENAULT_CELL_V1
- Request
22 90 21 - Service 22
DID 9021 - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1990 to 2026.
Cell 1 voltage RENAULT_CELL1_V1
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2026.
Cell 2 voltage RENAULT_CELL_V2
- Request
22 90 22 - Service 22
DID 9022 - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1990 to 2026.
Cell 2 voltage RENAULT_CELL1_V2
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2026.
Cell 3 voltage RENAULT_CELL_V3
- Request
22 90 23 - Service 22
DID 9023 - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1990 to 2026.
Cell 3 voltage RENAULT_CELL1_V3
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2026.
Cell 4 voltage RENAULT_CELL_V4
- Request
22 90 24 - Service 22
DID 9024 - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1990 to 2026.
Cell 4 voltage RENAULT_CELL1_V4
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 48 to 63 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2026.
Cell 5 voltage RENAULT_CELL_V5
- Request
22 90 25 - Service 22
DID 9025 - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1990 to 2026.
Cell 5 voltage RENAULT_CELL1_V5
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2026.
Cell 6 voltage RENAULT_CELL_V6
- Request
22 90 26 - Service 22
DID 9026 - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1990 to 2026.
Cell 6 voltage RENAULT_CELL1_V6
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 80 to 95 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2026.
Cell 7 voltage RENAULT_CELL_V7
- Request
22 90 27 - Service 22
DID 9027 - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1990 to 2026.
Cell 7 voltage RENAULT_CELL1_V7
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 96 to 111 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2026.
Cell 8 voltage RENAULT_CELL_V8
- Request
22 90 28 - Service 22
DID 9028 - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1990 to 2026.
Cell 8 voltage RENAULT_CELL1_V8
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 112 to 127 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2026.
Cell 9 voltage RENAULT_CELL_V9
- Request
22 90 29 - Service 22
DID 9029 - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1990 to 2026.
Cell 9 voltage RENAULT_CELL1_V9
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 128 to 143 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2026.
Cell 10 voltage RENAULT_CELL_V10
- Request
22 90 2A - Service 22
DID 902A - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1990 to 2026.
Cell 10 voltage RENAULT_CELL1_V10
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 144 to 159 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2026.
Cell 11 voltage RENAULT_CELL_V11
- Request
22 90 2B - Service 22
DID 902B - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1990 to 2026.
Cell 11 voltage RENAULT_CELL1_V11
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 160 to 175 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2026.
Cell 12 voltage RENAULT_CELL_V12
- Request
22 90 2C - Service 22
DID 902C - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1990 to 2026.
Cell 12 voltage RENAULT_CELL1_V12
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 176 to 191 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2026.
Cell 13 voltage RENAULT_CELL_V13
- Request
22 90 2D - Service 22
DID 902D - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1990 to 2026.
Cell 13 voltage RENAULT_CELL1_V13
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 192 to 207 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2026.
Cell 14 voltage RENAULT_CELL_V14
- Request
22 90 2E - Service 22
DID 902E - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1990 to 2026.
Cell 14 voltage RENAULT_CELL1_V14
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 208 to 223 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2026.
Cell 15 voltage RENAULT_CELL_V15
- Request
22 90 2F - Service 22
DID 902F - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1990 to 2026.
Cell 15 voltage RENAULT_CELL1_V15
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 224 to 239 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2026.
Cell 16 voltage RENAULT_CELL_V16
- Request
22 90 30 - Service 22
DID 9030 - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1990 to 2026.
Cell 16 voltage RENAULT_CELL1_V16
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 240 to 255 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2026.
Cell 17 voltage RENAULT_CELL_V17
- Request
22 90 31 - Service 22
DID 9031 - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1990 to 2026.
Cell 17 voltage RENAULT_CELL1_V17
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 256 to 271 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2026.
Cell 18 voltage RENAULT_CELL_V18
- Request
22 90 32 - Service 22
DID 9032 - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1990 to 2026.
Cell 18 voltage RENAULT_CELL1_V18
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 272 to 287 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2026.
Cell 19 voltage RENAULT_CELL_V19
- Request
22 90 33 - Service 22
DID 9033 - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1990 to 2026.
Cell 19 voltage RENAULT_CELL1_V19
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 288 to 303 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2026.
Cell 20 voltage RENAULT_CELL_V20
- Request
22 90 34 - Service 22
DID 9034 - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1990 to 2026.
Cell 20 voltage RENAULT_CELL1_V20
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 304 to 319 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2026.
Cell 21 voltage RENAULT_CELL_V21
- Request
22 90 35 - Service 22
DID 9035 - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1990 to 2026.
Cell 21 voltage RENAULT_CELL1_V21
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 320 to 335 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2026.
Cell 22 voltage RENAULT_CELL_V22
- Request
22 90 36 - Service 22
DID 9036 - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1990 to 2026.
Cell 22 voltage RENAULT_CELL1_V22
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 336 to 351 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2026.
Cell 23 voltage RENAULT_CELL_V23
- Request
22 90 37 - Service 22
DID 9037 - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1990 to 2026.
Cell 23 voltage RENAULT_CELL1_V23
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 352 to 367 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2026.
Cell 24 voltage RENAULT_CELL_V24
- Request
22 90 38 - Service 22
DID 9038 - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1990 to 2026.
Cell 24 voltage RENAULT_CELL1_V24
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 368 to 383 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2026.
Cell 25 voltage RENAULT_CELL_V25
- Request
22 90 39 - Service 22
DID 9039 - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1990 to 2026.
Cell 25 voltage RENAULT_CELL1_V25
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 384 to 399 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2026.
Cell 26 voltage RENAULT_CELL_V26
- Request
22 90 3A - Service 22
DID 903A - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1990 to 2026.
Cell 26 voltage RENAULT_CELL1_V26
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 400 to 415 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2026.
Cell 27 voltage RENAULT_CELL_V27
- Request
22 90 3B - Service 22
DID 903B - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1990 to 2026.
Cell 27 voltage RENAULT_CELL1_V27
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 416 to 431 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2026.
Cell 28 voltage RENAULT_CELL_V28
- Request
22 90 3C - Service 22
DID 903C - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1990 to 2026.
Cell 28 voltage RENAULT_CELL1_V28
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 432 to 447 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2026.
Cell 29 voltage RENAULT_CELL_V29
- Request
22 90 3D - Service 22
DID 903D - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1990 to 2026.
Cell 29 voltage RENAULT_CELL1_V29
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 448 to 463 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2026.
Cell 30 voltage RENAULT_CELL_V30
- Request
22 90 3E - Service 22
DID 903E - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1990 to 2026.
Cell 30 voltage RENAULT_CELL1_V30
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 464 to 479 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2026.
Cell 31 voltage RENAULT_CELL_V31
- Request
22 90 3F - Service 22
DID 903F - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1990 to 2026.
Cell 31 voltage RENAULT_CELL1_V31
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 480 to 495 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2026.
Cell 32 voltage RENAULT_CELL_V32
- Request
22 90 41 - Service 22
DID 9041 - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1990 to 2026.
Cell 32 voltage RENAULT_CELL1_V32
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 496 to 511 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2026.
Cell 33 voltage RENAULT_CELL_V33
- Request
22 90 42 - Service 22
DID 9042 - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1990 to 2026.
Cell 33 voltage RENAULT_CELL1_V33
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 512 to 527 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2026.
Cell 34 voltage RENAULT_CELL_V34
- Request
22 90 43 - Service 22
DID 9043 - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1990 to 2026.
Cell 34 voltage RENAULT_CELL1_V34
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 528 to 543 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2026.
Cell 35 voltage RENAULT_CELL_V35
- Request
22 90 44 - Service 22
DID 9044 - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1990 to 2026.
Cell 35 voltage RENAULT_CELL1_V35
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 544 to 559 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2026.
Cell 36 voltage RENAULT_CELL_V36
- Request
22 90 45 - Service 22
DID 9045 - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1990 to 2026.
Cell 36 voltage RENAULT_CELL1_V36
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 560 to 575 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2026.
Cell 37 voltage RENAULT_CELL_V37
- Request
22 90 46 - Service 22
DID 9046 - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1990 to 2026.
Cell 37 voltage RENAULT_CELL1_V37
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 576 to 591 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2026.
Cell 38 voltage RENAULT_CELL_V38
- Request
22 90 47 - Service 22
DID 9047 - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1990 to 2026.
Cell 38 voltage RENAULT_CELL1_V38
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 592 to 607 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2026.
Cell 39 voltage RENAULT_CELL_V39
- Request
22 90 48 - Service 22
DID 9048 - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1990 to 2026.
Cell 39 voltage RENAULT_CELL1_V39
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 608 to 623 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2026.
Cell 40 voltage RENAULT_CELL_V40
- Request
22 90 49 - Service 22
DID 9049 - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1990 to 2026.
Cell 40 voltage RENAULT_CELL1_V40
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 624 to 639 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2026.
Cell 41 voltage RENAULT_CELL_V41
- Request
22 90 4A - Service 22
DID 904A - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1990 to 2026.
Cell 41 voltage RENAULT_CELL1_V41
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 640 to 655 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2026.
Cell 42 voltage RENAULT_CELL_V42
- Request
22 90 4B - Service 22
DID 904B - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1990 to 2026.
Cell 42 voltage RENAULT_CELL1_V42
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 656 to 671 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2026.
Cell 43 voltage RENAULT_CELL_V43
- Request
22 90 4C - Service 22
DID 904C - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1990 to 2026.
Cell 43 voltage RENAULT_CELL1_V43
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 672 to 687 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2026.
Cell 44 voltage RENAULT_CELL_V44
- Request
22 90 4D - Service 22
DID 904D - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1990 to 2026.
Cell 44 voltage RENAULT_CELL1_V44
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 688 to 703 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2026.
Cell 45 voltage RENAULT_CELL_V45
- Request
22 90 4E - Service 22
DID 904E - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1990 to 2026.
Cell 45 voltage RENAULT_CELL1_V45
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 704 to 719 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2026.
Cell 46 voltage RENAULT_CELL_V46
- Request
22 90 4F - Service 22
DID 904F - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1990 to 2026.
Cell 46 voltage RENAULT_CELL1_V46
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 720 to 735 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2026.
Cell 47 voltage RENAULT_CELL_V47
- Request
22 90 50 - Service 22
DID 9050 - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1990 to 2026.
Cell 47 voltage RENAULT_CELL1_V47
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 736 to 751 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2026.
Cell 48 voltage RENAULT_CELL_V48
- Request
22 90 51 - Service 22
DID 9051 - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1990 to 2026.
Cell 48 voltage RENAULT_CELL1_V48
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 752 to 767 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2026.
Cell 49 voltage RENAULT_CELL_V49
- Request
22 90 52 - Service 22
DID 9052 - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1990 to 2026.
Cell 49 voltage RENAULT_CELL1_V49
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 768 to 783 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2026.
Cell 50 voltage RENAULT_CELL_V50
- Request
22 90 53 - Service 22
DID 9053 - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1990 to 2026.
Cell 50 voltage RENAULT_CELL1_V50
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 784 to 799 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2026.
Cell 51 voltage RENAULT_CELL_V51
- Request
22 90 54 - Service 22
DID 9054 - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1990 to 2026.
Cell 51 voltage RENAULT_CELL1_V51
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 800 to 815 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2026.
Cell 52 voltage RENAULT_CELL_V52
- Request
22 90 55 - Service 22
DID 9055 - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1990 to 2026.
Cell 52 voltage RENAULT_CELL1_V52
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 816 to 831 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2026.
Cell 53 voltage RENAULT_CELL_V53
- Request
22 90 56 - Service 22
DID 9056 - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1990 to 2026.
Cell 53 voltage RENAULT_CELL1_V53
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 832 to 847 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2026.
Cell 54 voltage RENAULT_CELL_V54
- Request
22 90 57 - Service 22
DID 9057 - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1990 to 2026.
Cell 54 voltage RENAULT_CELL1_V54
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 848 to 863 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2026.
Cell 55 voltage RENAULT_CELL_V55
- Request
22 90 58 - Service 22
DID 9058 - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1990 to 2026.
Cell 55 voltage RENAULT_CELL1_V55
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 864 to 879 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2026.
Cell 56 voltage RENAULT_CELL_V56
- Request
22 90 59 - Service 22
DID 9059 - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1990 to 2026.
Cell 56 voltage RENAULT_CELL1_V56
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 880 to 895 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2026.
Cell 57 voltage RENAULT_CELL_V57
- Request
22 90 5A - Service 22
DID 905A - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1990 to 2026.
Cell 57 voltage RENAULT_CELL1_V57
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 896 to 911 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2026.
Cell 58 voltage RENAULT_CELL_V58
- Request
22 90 5B - Service 22
DID 905B - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1990 to 2026.
Cell 58 voltage RENAULT_CELL1_V58
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 912 to 927 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2026.
Cell 59 voltage RENAULT_CELL_V59
- Request
22 90 5C - Service 22
DID 905C - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1990 to 2026.
Cell 59 voltage RENAULT_CELL1_V59
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 928 to 943 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2026.
Cell 60 voltage RENAULT_CELL_V60
- Request
22 90 5D - Service 22
DID 905D - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1990 to 2026.
Cell 60 voltage RENAULT_CELL1_V60
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 944 to 959 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2026.
Cell 61 voltage RENAULT_CELL_V61
- Request
22 90 5E - Service 22
DID 905E - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1990 to 2026.
Cell 61 voltage RENAULT_CELL1_V61
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 960 to 975 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2026.
Cell 62 voltage RENAULT_CELL_V62
- Request
22 90 5F - Service 22
DID 905F - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1990 to 2026.
Cell 62 voltage RENAULT_CELL1_V62
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 976 to 991 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2026.
Cell 63 voltage RENAULT_CELL_V63
- Request
22 90 61 - Service 22
DID 9061 - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1990 to 2026.
Cell 63 voltage RENAULT_CELL1_V63
- Request
21 42 - Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2026.
Cell 64 voltage RENAULT_CELL_V64
- Request
22 90 62 - Service 22
DID 9062 - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1990 to 2026.
Cell 64 voltage RENAULT_CELL1_V64
- Request
21 42 - Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2026.
Cell 65 voltage RENAULT_CELL_V65
- Request
22 90 63 - Service 22
DID 9063 - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1990 to 2026.
Cell 65 voltage RENAULT_CELL1_V65
- Request
21 42 - Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2026.
Cell 66 voltage RENAULT_CELL_V66
- Request
22 90 64 - Service 22
DID 9064 - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1990 to 2026.
Cell 66 voltage RENAULT_CELL1_V66
- Request
21 42 - Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 48 to 63 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2026.
Cell 67 voltage RENAULT_CELL_V67
- Request
22 90 65 - Service 22
DID 9065 - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1990 to 2026.
Cell 67 voltage RENAULT_CELL1_V67
- Request
21 42 - Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2026.
Cell 68 voltage RENAULT_CELL_V68
- Request
22 90 66 - Service 22
DID 9066 - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1990 to 2026.
Cell 68 voltage RENAULT_CELL1_V68
- Request
21 42 - Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 80 to 95 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2026.
Cell 69 voltage RENAULT_CELL_V69
- Request
22 90 67 - Service 22
DID 9067 - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1990 to 2026.
Cell 69 voltage RENAULT_CELL1_V69
- Request
21 42 - Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 96 to 111 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2026.
Cell 70 voltage RENAULT_CELL_V70
- Request
22 90 68 - Service 22
DID 9068 - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1990 to 2026.
Cell 70 voltage RENAULT_CELL1_V70
- Request
21 42 - Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 112 to 127 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2026.
Cell 71 voltage RENAULT_CELL_V71
- Request
22 90 69 - Service 22
DID 9069 - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1990 to 2026.
Cell 71 voltage RENAULT_CELL1_V71
- Request
21 42 - Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 128 to 143 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2026.
Cell 72 voltage RENAULT_CELL_V72
- Request
22 90 6A - Service 22
DID 906A - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1990 to 2026.
Cell 72 voltage RENAULT_CELL1_V72
- Request
21 42 - Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 144 to 159 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2026.
Cell 73 voltage RENAULT_CELL_V73
- Request
22 90 6B - Service 22
DID 906B - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1990 to 2026.
Cell 73 voltage RENAULT_CELL1_V73
- Request
21 42 - Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 160 to 175 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2026.
Cell 74 voltage RENAULT_CELL_V74
- Request
22 90 6C - Service 22
DID 906C - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1990 to 2026.
Cell 74 voltage RENAULT_CELL1_V74
- Request
21 42 - Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 176 to 191 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2026.
Cell 75 voltage RENAULT_CELL_V75
- Request
22 90 6D - Service 22
DID 906D - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1990 to 2026.
Cell 75 voltage RENAULT_CELL1_V75
- Request
21 42 - Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 192 to 207 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2026.
Cell 76 voltage RENAULT_CELL_V76
- Request
22 90 6E - Service 22
DID 906E - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1990 to 2026.
Cell 76 voltage RENAULT_CELL1_V76
- Request
21 42 - Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 208 to 223 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2026.
Cell 77 voltage RENAULT_CELL_V77
- Request
22 90 6F - Service 22
DID 906F - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1990 to 2026.
Cell 77 voltage RENAULT_CELL1_V77
- Request
21 42 - Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 224 to 239 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2026.
Cell 78 voltage RENAULT_CELL_V78
- Request
22 90 70 - Service 22
DID 9070 - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1990 to 2026.
Cell 78 voltage RENAULT_CELL1_V78
- Request
21 42 - Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 240 to 255 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2026.
Cell 79 voltage RENAULT_CELL_V79
- Request
22 90 71 - Service 22
DID 9071 - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1990 to 2026.
Cell 79 voltage RENAULT_CELL1_V79
- Request
21 42 - Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 256 to 271 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2026.
Cell 80 voltage RENAULT_CELL_V80
- Request
22 90 72 - Service 22
DID 9072 - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1990 to 2026.
Cell 80 voltage RENAULT_CELL1_V80
- Request
21 42 - Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 272 to 287 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2026.
Cell 81 voltage RENAULT_CELL_V81
- Request
22 90 73 - Service 22
DID 9073 - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1990 to 2026.
Cell 81 voltage RENAULT_CELL1_V81
- Request
21 42 - Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 288 to 303 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2026.
Cell 82 voltage RENAULT_CELL_V82
- Request
22 90 74 - Service 22
DID 9074 - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1990 to 2026.
Cell 82 voltage RENAULT_CELL1_V82
- Request
21 42 - Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 304 to 319 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2026.
Cell 83 voltage RENAULT_CELL_V83
- Request
22 90 75 - Service 22
DID 9075 - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1990 to 2026.
Cell 83 voltage RENAULT_CELL1_V83
- Request
21 42 - Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 320 to 335 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2026.
Cell 84 voltage RENAULT_CELL_V84
- Request
22 90 76 - Service 22
DID 9076 - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1990 to 2026.
Cell 84 voltage RENAULT_CELL1_V84
- Request
21 42 - Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 336 to 351 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2026.
Cell 85 voltage RENAULT_CELL_V85
- Request
22 90 77 - Service 22
DID 9077 - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1990 to 2026.
Cell 85 voltage RENAULT_CELL1_V85
- Request
21 42 - Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 352 to 367 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2026.
Cell 86 voltage RENAULT_CELL_V86
- Request
22 90 78 - Service 22
DID 9078 - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1990 to 2026.
Cell 86 voltage RENAULT_CELL1_V86
- Request
21 42 - Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 368 to 383 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2026.
Cell 87 voltage RENAULT_CELL_V87
- Request
22 90 79 - Service 22
DID 9079 - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1990 to 2026.
Cell 87 voltage RENAULT_CELL1_V87
- Request
21 42 - Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 384 to 399 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2026.
Cell 88 voltage RENAULT_CELL_V88
- Request
22 90 7A - Service 22
DID 907A - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1990 to 2026.
Cell 88 voltage RENAULT_CELL1_V88
- Request
21 42 - Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 400 to 415 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2026.
Cell 89 voltage RENAULT_CELL_V89
- Request
22 90 7B - Service 22
DID 907B - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1990 to 2026.
Cell 89 voltage RENAULT_CELL1_V89
- Request
21 42 - Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 416 to 431 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2026.
Cell 90 voltage RENAULT_CELL_V90
- Request
22 90 7C - Service 22
DID 907C - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1990 to 2026.
Cell 90 voltage RENAULT_CELL1_V90
- Request
21 42 - Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 432 to 447 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2026.
Cell 91 voltage RENAULT_CELL_V91
- Request
22 90 7D - Service 22
DID 907D - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1990 to 2026.
Cell 91 voltage RENAULT_CELL1_V91
- Request
21 42 - Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 448 to 463 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2026.
Cell 92 voltage RENAULT_CELL_V92
- Request
22 90 7E - Service 22
DID 907E - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1990 to 2026.
Cell 92 voltage RENAULT_CELL1_V92
- Request
21 42 - Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 464 to 479 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2026.
Cell 93 voltage RENAULT_CELL_V93
- Request
22 90 7F - Service 22
DID 907F - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1990 to 2026.
Cell 93 voltage RENAULT_CELL1_V93
- Request
21 42 - Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 480 to 495 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2026.
Cell 94 voltage RENAULT_CELL_V94
- Request
22 90 81 - Service 22
DID 9081 - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1990 to 2026.
Cell 94 voltage RENAULT_CELL1_V94
- Request
21 42 - Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 496 to 511 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2026.
Cell 95 voltage RENAULT_CELL_V95
- Request
22 90 82 - Service 22
DID 9082 - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1990 to 2026.
Cell 95 voltage RENAULT_CELL1_V95
- Request
21 42 - Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 512 to 527 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2026.
Cell 96 voltage RENAULT_CELL_V96
- Request
22 90 83 - Service 22
DID 9083 - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1990 to 2026.
Cell 96 voltage RENAULT_CELL1_V96
- Request
21 42 - Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 528 to 543 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2026.