Renault Clio

Electrical parameters

The Renault Clio has 8 electrical parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

12V battery current RENAULT_12V_A

  • Request22 60 79
  • Service 22DID 6079
  • Module74D → 76D
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 6553.5 A
Unit
A

In testing for 1990 to 2026.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

12V battery current RENAULT_12V_A

  • Request22 60 79
  • Service 22DID 6079
  • Module74D → 76D
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 6553.5 A
Unit
A

In testing for 1990 to 2026.

12V battery voltage RENAULT_12V_V

Pelican can show this parameter as the starter battery voltage.

  • Request22 20 05
  • Service 22DID 2005
  • ModuleDADA → DA
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 655.35 V
Unit
V

In testing for 1990 to 2026.

Alternator load RENAULT_ALT_LOAD

  • Request22 20 99
  • Service 22DID 2099
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

In testing for 1990 to 2026.

Alternator power RENAULT_ALT_PWR

  • Request22 20 57
  • Service 22DID 2057
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 10)
Range
0 to 655350 W
Unit
W

In testing for 1990 to 2026.

Brake lights request RENAULT_BRAKE_LIGHTS

  • Request22 4B 15
  • Service 22DID 4B15
  • Module740 → 760
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1990 to 2026.

Hazard lights LED RENAULT_HAZARD_LED

  • Request22 4B 14
  • Service 22DID 4B14
  • Module740 → 760
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1990 to 2026.

Sensor feed voltage 1 RENAULT_SNS_FEED_V1

  • Request22 20 21
  • Service 22DID 2021
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 1990 to 2026.

Sensor feed voltage 2 RENAULT_SNS_FEED_V2

  • Request22 20 22
  • Service 22DID 2022
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 1990 to 2026.

Keyboard shortcuts

jk/↓↑
Move down or up through a list or a grid.
hl/←→
Move across a row or between cards.
Enter
Open the focused link.
f
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.