Engine parameters
The Kia Stinger has 191 engine parameters.
● Confirmed◆ In testing○ Supported× Not supported
4WD clutch duty STINGER_AWD_CLU_DUTYConfirmed
- Request
22 01 A1 - Service 22
DID 01A1 - Module
740 → 748 - Every
250 ms - Testing for 2018 to 2019, 2021 to 2023
Example reply from a 2020 Kia Stinger.
Bits 72 to 87 of the reply, 16 bits. The value is signed.
0x0068 = 104 → (104 ÷ 10) = 10.4 %
- Formula
(val ÷ 10)- Range
- -3276.8 to 100 %
- Unit
- %
Confirmed for 2020. In testing for 2018 to 2019, 2021 to 2023.
4WD clutch pressure STINGER_AWD_CLU_PConfirmed
- Request
22 01 A1 - Service 22
DID 01A1 - Module
740 → 748 - Every
250 ms - Testing for 2018 to 2019, 2021 to 2023
Bits 216 to 231 of the reply, 16 bits. The value is signed.
- Formula
(val × 0.001953)- Range
- -63.99 to 63.99 bar
- Unit
- bar
Confirmed for 2020. In testing for 2018 to 2019, 2021 to 2023.
4WD clutch stress STINGER_AWD_CLU_STRESSConfirmed
- Request
22 01 A1 - Service 22
DID 01A1 - Module
740 → 748 - Every
250 ms - Testing for 2018 to 2019, 2021 to 2023
Example reply from a 2020 Kia Stinger.
Bits 104 to 119 of the reply, 16 bits. The value is signed.
0x0000 = 0 → (0 × 0.001953) = 0 %
- Formula
(val × 0.001953)- Range
- -63.99 to 63.99 %
- Unit
- %
Confirmed for 2020. In testing for 2018 to 2019, 2021 to 2023.
4WD clutch torque STINGER_AWD_CLU_TQConfirmed
- Request
22 01 A1 - Service 22
DID 01A1 - Module
740 → 748 - Every
250 ms - Testing for 2018 to 2019, 2021 to 2023
Example reply from a 2020 Kia Stinger.
Bits 200 to 215 of the reply, 16 bits. The value is signed.
0x0000 = 0 → (0 ÷ 16) = 0 N·m
- Formula
(val ÷ 16)- Range
- -2048 to 2047.9375 N·m
- Unit
- N·m
Confirmed for 2020. In testing for 2018 to 2019, 2021 to 2023.
4WD front axle ratio STINGER_AWD_FRONT_AXLE_RATConfirmed
- Request
22 01 A3 - Service 22
DID 01A3 - Module
740 → 748 - Every
250 ms - Testing for 2018 to 2019, 2021 to 2023
Bits 56 to 71 of the reply, 16 bits. The value is signed.
- Formula
(val × 2 ÷ 65535)- Range
- -1 to 0.999
- Unit
- Number
Confirmed for 2020. In testing for 2018 to 2019, 2021 to 2023.
Absolute load value LOAD_ABSSAE J1979Confirmed
- Request
01 43 - Service 01
PID 43 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 25700 %
- Unit
- %
Confirmed for 2018, 2020. Supported for 2022 to 2023.
Actual engine torque TQ_ACTSAE J1979Confirmed
- Request
01 62 - Service 01
PID 62 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 125)- Range
- -125 to 130 %
- Unit
- %
Confirmed for 2020.
Air conditioning pressure STINGER_AC_PConfirmed
- Request
22 E0 14 - Service 22
DID E014 - Module
7E0 → 7E8 - Every
5 s - Testing for 2018 to 2019, 2021 to 2023
Example reply from a 2020 Kia Stinger.
Bits 112 to 119 of the reply, 8 bits.
0x40 = 64 → (64 × 3520 ÷ 255) = 883.45098 kPa
- Formula
(val × 3520 ÷ 255)- Range
- 0 to 3520 kPa
- Unit
- kPa
Confirmed for 2020. In testing for 2018 to 2019, 2021 to 2023.
Air conditioning relay STINGER_AC_RELAY
- Request
22 ED 01 - Service 22
DID ED01 - Module
7E0 → 7E8 - Every
5 s - Testing
Bit 101 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2018 to 2019, 2021 to 2023. Not supported for 2020.
Automatic transmission fluid temperature STINGER_ATF_T_7E1Confirmed
Pelican can show this parameter as the transmission fluid temperature.
- Request
22 01 A0 - Service 22
DID 01A0 - Module
7E1 → 7E9 - Every
250 ms - Testing for 2018, 2021
Example reply from a 2023 Kia Stinger.
Bits 104 to 111 of the reply, 8 bits.
0x5A = 90 → (90 − 40) = 50 °C
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2019 to 2020, 2022 to 2023. In testing for 2018, 2021.
Barometric pressure BAROSAE J1979Confirmed
Normally obtained from one of a dedicated barometric sensor, a MAP sensor at key-on and during certain modes of driving, or inferred from a MAF sensor and other inputs during certain modes of driving. The control module reports BARO from whatever source it is derived from.
- Request
01 33 - Service 01
PID 33 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 kPa
- Unit
- kPa
Confirmed for 2018, 2020. Supported for 2019, 2021 to 2023.
Barometric pressure STINGER_BAROMETRIC_PRESSURE
- Request
21 13 - Service 21
PID 13 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 312 to 319 of the reply, 8 bits.
- Formula
(val ÷ 2)- Range
- 0 to 127.5 kPa
- Unit
- kPa
In testing for 2018 to 2019, 2021. Not supported for 2020, 2022 to 2023.
Calculated engine load LOAD_PCTSAE J1979Confirmed
Represents the amount of work the engine is doing. Expected to reach 100% at wide open throttle/wide open pedal at any altitude, temperature or rpm for both naturally aspirated and boosted engines. If engine load is limited for powertrain protection e.g. engine/turbocharger protection, this value may not reach 100%. For hybrid vehicles, indicates the torque produced only by the internal combustion engine, not the torque being delivered by the entire powertrain. For electric vehicles, the meaning of this parameter is undefined.
Pelican can show this parameter as the engine load.
- Request
01 04 - Service 01
PID 04 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2018, 2020 to 2023. Supported for 2019.
Catalyst damaging misfires total all cylinders STINGER_CATALYST_DAMAGING_MISFIRES_TOTAL_ALL_CYLINDERS
- Request
22 E0 0D - Service 22
DID E00D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 448 to 463 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2018 to 2019, 2021, 2023. Not supported for 2020, 2022.
Catalyst damaging misfires total, cylinder 1 STINGER_CATALYST_DAMAGING_MISFIRES_TOTAL_C1
- Request
22 E0 0D - Service 22
DID E00D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 304 to 319 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2018 to 2019, 2021, 2023. Not supported for 2020, 2022.
Catalyst damaging misfires total, cylinder 1 STINGER_CATDMG_MIS_TOT_1Confirmed
- Request
22 E0 1D - Service 22
DID E01D - Module
7E0 → 7E8 - Every
1 s - Testing for 2018 to 2019, 2021 to 2023
Example reply from a 2020 Kia Stinger.
Bits 160 to 175 of the reply, 16 bits. The bytes are in little-endian order.
0x0000 = 0 → 0
- Formula
val- Range
- 0 to 65535
- Unit
- Number
Confirmed for 2020. In testing for 2018 to 2019, 2021 to 2023.
Catalyst damaging misfires total, cylinder 2 STINGER_CATALYST_DAMAGING_MISFIRES_TOTAL_C2
- Request
22 E0 0D - Service 22
DID E00D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 320 to 335 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2018 to 2019, 2021, 2023. Not supported for 2020, 2022.
Catalyst damaging misfires total, cylinder 2 STINGER_CATDMG_MIS_TOT_2Confirmed
- Request
22 E0 1D - Service 22
DID E01D - Module
7E0 → 7E8 - Every
1 s - Testing for 2018 to 2019, 2021 to 2023
Example reply from a 2020 Kia Stinger.
Bits 176 to 191 of the reply, 16 bits. The bytes are in little-endian order.
0x0000 = 0 → 0
- Formula
val- Range
- 0 to 65535
- Unit
- Number
Confirmed for 2020. In testing for 2018 to 2019, 2021 to 2023.
Catalyst damaging misfires total, cylinder 3 STINGER_CATALYST_DAMAGING_MISFIRES_TOTAL_C3
- Request
22 E0 0D - Service 22
DID E00D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 336 to 351 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2018 to 2019, 2021, 2023. Not supported for 2020, 2022.
Catalyst damaging misfires total, cylinder 3 STINGER_CATDMG_MIS_TOT_3Confirmed
- Request
22 E0 1D - Service 22
DID E01D - Module
7E0 → 7E8 - Every
1 s - Testing for 2018 to 2019, 2021 to 2023
Example reply from a 2020 Kia Stinger.
Bits 192 to 207 of the reply, 16 bits. The bytes are in little-endian order.
0x0000 = 0 → 0
- Formula
val- Range
- 0 to 65535
- Unit
- Number
Confirmed for 2020. In testing for 2018 to 2019, 2021 to 2023.
Catalyst damaging misfires total, cylinder 4 STINGER_CATALYST_DAMAGING_MISFIRES_TOTAL_C4
- Request
22 E0 0D - Service 22
DID E00D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 352 to 367 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2018 to 2019, 2021, 2023. Not supported for 2020, 2022.
Catalyst damaging misfires total, cylinder 4 STINGER_CATDMG_MIS_TOT_4Confirmed
- Request
22 E0 1D - Service 22
DID E01D - Module
7E0 → 7E8 - Every
1 s - Testing for 2018 to 2019, 2021 to 2023
Example reply from a 2020 Kia Stinger.
Bits 208 to 223 of the reply, 16 bits. The bytes are in little-endian order.
0x0000 = 0 → 0
- Formula
val- Range
- 0 to 65535
- Unit
- Number
Confirmed for 2020. In testing for 2018 to 2019, 2021 to 2023.
Catalyst temperature bank 1, sensor 1 CATEMP11SAE J1979Confirmed
- Request
01 3C - Service 01
PID 3C - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10 − 40)- Range
- -40 to 6513.5 °C
- Unit
- °C
Confirmed for 2018, 2020. Supported for 2019, 2021 to 2023.
Catalyst temperature bank 1, sensor 2 CATEMP12SAE J1979Confirmed
- Request
01 3E - Service 01
PID 3E - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10 − 40)- Range
- -40 to 6513.5 °C
- Unit
- °C
Confirmed for 2018, 2020. Supported for 2019, 2021 to 2023.
Catalyst temperature bank 2, sensor 1 CATEMP21SAE J1979Confirmed
- Request
01 3D - Service 01
PID 3D - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10 − 40)- Range
- -40 to 6513.5 °C
- Unit
- °C
Confirmed for 2020. Supported for 2019, 2021 to 2022.
Catalyst temperature bank 2, sensor 2 CATEMP22SAE J1979Confirmed
- Request
01 3F - Service 01
PID 3F - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10 − 40)- Range
- -40 to 6513.5 °C
- Unit
- °C
Confirmed for 2020. Supported for 2019, 2021 to 2022.
Clutch solenoid duty STINGER_CLUTCH_SOLENOID_DUTY
- Request
21 C0 - Service 21
PID C0 - Module
7E5 - Every
250 ms - Testing
Bits 88 to 95 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 %
- Unit
- %
In testing for 2018, 2021. Not supported for 2019 to 2020, 2022 to 2023.
Commanded equivalence ratio EQ_RATSAE J1979Confirmed
Fuel systems that utilize conventional oxygen sensor display the inverse of the commanded open loop equivalence ratio (also known as lambda) while the fuel control system is in open loop. Will indicate 1.000 while in closed-loop fuel.
Pelican can show this parameter as the commanded lambda.
- Request
01 44 - Service 01
PID 44 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 2 ÷ 65535)- Range
- 0 to 1.99
- Unit
- Number
Confirmed for 2018 to 2023.
Commanded evaporative purge EVAP_PCTSAE J1979Confirmed
- Request
01 2E - Service 01
PID 2E - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2018, 2020. Supported for 2019, 2021 to 2023.
Commanded evaporative purge STINGER_COMMANDED_EVAPORATIVE_PURGE
- Request
21 02 - Service 21
PID 02 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 160 to 167 of the reply, 8 bits.
- Formula
(val × 0.390625)- Range
- 0 to 99.6 %
- Unit
- %
In testing for 2018, 2021. Not supported for 2019 to 2020, 2022 to 2023.
Commanded throttle actuator STINGER_COMMANDED_THROTTLE_ACTUATOR
- Request
21 14 - Service 21
PID 14 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val × 0.390625)- Range
- 0 to 99.6 %
- Unit
- %
In testing for 2018 to 2019, 2021. Not supported for 2020, 2022 to 2023.
Commanded throttle actuator control TAC_PCTSAE J1979Confirmed
- Request
01 4C - Service 01
PID 4C - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2018, 2020.
Commanded torque STINGER_COMMANDED_TORQUE
- Request
21 C0 - Service 21
PID C0 - Module
7E5 - Every
250 ms - Testing
Bits 80 to 87 of the reply, 8 bits.
- Formula
(val × 10)- Range
- 0 to 2550 N·m
- Unit
- N·m
In testing for 2018, 2021. Not supported for 2019 to 2020, 2022 to 2023.
Coolant STINGER_COOLANT_FAN
- Request
21 14 - Service 21
PID 14 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 96 to 103 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2018 to 2019, 2021. Not supported for 2020, 2022 to 2023.
Coolant fan PWM STINGER_CLT_FAN_PWMConfirmed
- Request
22 E0 14 - Service 22
DID E014 - Module
7E0 → 7E8 - Every
5 s - Testing for 2018 to 2019, 2021 to 2023
Example reply from a 2020 Kia Stinger.
Bits 88 to 95 of the reply, 8 bits.
0x45 = 69 → (69 × 100 ÷ 255) = 27.058824 %
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2020. In testing for 2018 to 2019, 2021 to 2023.
Diesel particulate filter differential pressure STINGER_DPF_DIFF_PConfirmed
- Request
22 E0 F1 - Service 22
DID E0F1 - Module
7E0 → 7E8 - Every
1 s - Testing for 2018 to 2019, 2021 to 2023
Example reply from a 2020 Kia Stinger.
Bits 248 to 255 of the reply, 8 bits.
0x00 = 0 → (0 × 431.373 ÷ 100 − 100) = -100
- Formula
(val × 431.373 ÷ 100 − 100)- Range
- -100 to 1000
- Unit
- Raw value
Confirmed for 2020. In testing for 2018 to 2019, 2021 to 2023.
Diesel particulate filter differential pressure STINGER_DPF_DIFFERENTIAL_PRESSURE
- Request
21 1B - Service 21
PID 1B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 2)- Range
- 0 to 32767.5
- Unit
- Raw value
In testing for 2018, 2021. Not supported for 2019 to 2020, 2022 to 2023.
Diesel particulate filter regeneration count STINGER_DPF_REGEN_CNT
- Request
22 ED 03 - Service 22
DID ED03 - Module
7E0 → 7E8 - Every
30 s - Testing
Bits 440 to 447 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2018 to 2019, 2021 to 2023. Not supported for 2020.
Diesel particulate filter regeneration state STINGER_DPF_REGEN_ST
- Request
22 ED 03 - Service 22
DID ED03 - Module
7E0 → 7E8 - Every
30 s - Testing
Bit 431 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2018 to 2019, 2021 to 2023. Not supported for 2020.
Diesel particulate filter regeneration state STINGER_DPF_REGENERATION_STATE
- Request
21 06 - Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 207 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2018, 2021. Not supported for 2019 to 2020, 2022 to 2023.
Diesel particulate filter soot mass STINGER_DPF_SOOT_MASS
- Request
22 ED 94 - Service 22
DID ED94 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 56 to 63 of the reply, 8 bits.
- Formula
(val × 99 ÷ 255)- Range
- 0 to 99
- Unit
- Raw value
In testing for 2018 to 2019, 2021 to 2023. Not supported for 2020.
Diesel particulate filter total sulfur mass STINGER_DPF_TOT_SULFUR_MASS
- Request
22 ED 29 - Service 22
DID ED29 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.15259)- Range
- 0 to 9999
- Unit
- Raw value
In testing for 2018 to 2019, 2021 to 2023. Not supported for 2020.
Direct injection time 1st pulse, cylinder 1 STINGER_DI_TIME_1ST_CYL_1Confirmed
- Request
22 E0 23 - Service 22
DID E023 - Module
7E0 → 7E8 - Every
1 s - Testing for 2018 to 2019, 2021 to 2023
Example reply from a 2020 Kia Stinger.
Bits 264 to 279 of the reply, 16 bits. The bytes are in little-endian order.
0x0110 = 272 → (272 × 4 ÷ 1000) = 1.088 ms
- Formula
(val × 4 ÷ 1000)- Range
- 0 to 262.14 ms
- Unit
- ms
Confirmed for 2020. In testing for 2018 to 2019, 2021 to 2023.
Direct injection time 1st pulse, cylinder 2 STINGER_DI_TIME_1ST_CYL_2Confirmed
- Request
22 E0 23 - Service 22
DID E023 - Module
7E0 → 7E8 - Every
1 s - Testing for 2018 to 2019, 2021 to 2023
Example reply from a 2020 Kia Stinger.
Bits 280 to 295 of the reply, 16 bits. The bytes are in little-endian order.
0x0109 = 265 → (265 × 4 ÷ 1000) = 1.06 ms
- Formula
(val × 4 ÷ 1000)- Range
- 0 to 262.14 ms
- Unit
- ms
Confirmed for 2020. In testing for 2018 to 2019, 2021 to 2023.
Direct injection time 1st pulse, cylinder 3 STINGER_DI_TIME_1ST_CYL_3Confirmed
- Request
22 E0 23 - Service 22
DID E023 - Module
7E0 → 7E8 - Every
1 s - Testing for 2018 to 2019, 2021 to 2023
Example reply from a 2020 Kia Stinger.
Bits 296 to 311 of the reply, 16 bits. The bytes are in little-endian order.
0x0111 = 273 → (273 × 4 ÷ 1000) = 1.092 ms
- Formula
(val × 4 ÷ 1000)- Range
- 0 to 262.14 ms
- Unit
- ms
Confirmed for 2020. In testing for 2018 to 2019, 2021 to 2023.
Direct injection time 1st pulse, cylinder 4 STINGER_DI_TIME_1ST_CYL_4Confirmed
- Request
22 E0 23 - Service 22
DID E023 - Module
7E0 → 7E8 - Every
1 s - Testing for 2018 to 2019, 2021 to 2023
Example reply from a 2020 Kia Stinger.
Bits 312 to 327 of the reply, 16 bits. The bytes are in little-endian order.
0x0112 = 274 → (274 × 4 ÷ 1000) = 1.096 ms
- Formula
(val × 4 ÷ 1000)- Range
- 0 to 262.14 ms
- Unit
- ms
Confirmed for 2020. In testing for 2018 to 2019, 2021 to 2023.
Direct injection time 1st pulse, cylinder 5 STINGER_CYL5_INJ_TIME_1STConfirmed
- Request
22 E0 23 - Service 22
DID E023 - Module
7E0 → 7E8 - Every
1 s - Testing for 2018 to 2019, 2021 to 2023
Example reply from a 2020 Kia Stinger.
Bits 392 to 407 of the reply, 16 bits. The bytes are in little-endian order.
0x010F = 271 → (271 × 4 ÷ 1000) = 1.084 ms
- Formula
(val × 4 ÷ 1000)- Range
- 0 to 262.14 ms
- Unit
- ms
Confirmed for 2020. In testing for 2018 to 2019, 2021 to 2023.
Direct injection time 1st pulse, cylinder 6 STINGER_CYL6_INJ_TIME_1STConfirmed
- Request
22 E0 23 - Service 22
DID E023 - Module
7E0 → 7E8 - Every
1 s - Testing for 2018 to 2019, 2021 to 2023
Example reply from a 2020 Kia Stinger.
Bits 408 to 423 of the reply, 16 bits. The bytes are in little-endian order.
0x011C = 284 → (284 × 4 ÷ 1000) = 1.136 ms
- Formula
(val × 4 ÷ 1000)- Range
- 0 to 262.14 ms
- Unit
- ms
Confirmed for 2020. In testing for 2018 to 2019, 2021 to 2023.
Direct injection time 2nd pulse, cylinder 1 STINGER_DI_TIME_2ND_CYL_1Confirmed
- Request
22 E0 23 - Service 22
DID E023 - Module
7E0 → 7E8 - Every
1 s - Testing for 2018 to 2019, 2021 to 2023
Example reply from a 2020 Kia Stinger.
Bits 200 to 215 of the reply, 16 bits. The bytes are in little-endian order.
0x0000 = 0 → (0 × 4 ÷ 1000) = 0 ms
- Formula
(val × 4 ÷ 1000)- Range
- 0 to 262.14 ms
- Unit
- ms
Confirmed for 2020. In testing for 2018 to 2019, 2021 to 2023.
Direct injection time 2nd pulse, cylinder 2 STINGER_DI_TIME_2ND_CYL_2Confirmed
- Request
22 E0 23 - Service 22
DID E023 - Module
7E0 → 7E8 - Every
1 s - Testing for 2018 to 2019, 2021 to 2023
Example reply from a 2020 Kia Stinger.
Bits 216 to 231 of the reply, 16 bits. The bytes are in little-endian order.
0x0000 = 0 → (0 × 4 ÷ 1000) = 0 ms
- Formula
(val × 4 ÷ 1000)- Range
- 0 to 262.14 ms
- Unit
- ms
Confirmed for 2020. In testing for 2018 to 2019, 2021 to 2023.
Direct injection time 2nd pulse, cylinder 3 STINGER_DI_TIME_2ND_CYL_3Confirmed
- Request
22 E0 23 - Service 22
DID E023 - Module
7E0 → 7E8 - Every
1 s - Testing for 2018 to 2019, 2021 to 2023
Example reply from a 2020 Kia Stinger.
Bits 232 to 247 of the reply, 16 bits. The bytes are in little-endian order.
0x0000 = 0 → (0 × 4 ÷ 1000) = 0 ms
- Formula
(val × 4 ÷ 1000)- Range
- 0 to 262.14 ms
- Unit
- ms
Confirmed for 2020. In testing for 2018 to 2019, 2021 to 2023.
Direct injection time 2nd pulse, cylinder 4 STINGER_DI_TIME_2ND_CYL_4Confirmed
- Request
22 E0 23 - Service 22
DID E023 - Module
7E0 → 7E8 - Every
1 s - Testing for 2018 to 2019, 2021 to 2023
Example reply from a 2020 Kia Stinger.
Bits 248 to 263 of the reply, 16 bits. The bytes are in little-endian order.
0x0000 = 0 → (0 × 4 ÷ 1000) = 0 ms
- Formula
(val × 4 ÷ 1000)- Range
- 0 to 262.14 ms
- Unit
- ms
Confirmed for 2020. In testing for 2018 to 2019, 2021 to 2023.
Direct injection time 2nd pulse, cylinder 5 STINGER_CYL5_INJ_TIME_2NDConfirmed
- Request
22 E0 23 - Service 22
DID E023 - Module
7E0 → 7E8 - Every
1 s - Testing for 2018 to 2019, 2021 to 2023
Example reply from a 2020 Kia Stinger.
Bits 360 to 375 of the reply, 16 bits. The bytes are in little-endian order.
0x0000 = 0 → (0 × 4 ÷ 1000) = 0 ms
- Formula
(val × 4 ÷ 1000)- Range
- 0 to 262.14 ms
- Unit
- ms
Confirmed for 2020. In testing for 2018 to 2019, 2021 to 2023.
Direct injection time 2nd pulse, cylinder 6 STINGER_CYL6_INJ_TIME_2NDConfirmed
- Request
22 E0 23 - Service 22
DID E023 - Module
7E0 → 7E8 - Every
1 s - Testing for 2018 to 2019, 2021 to 2023
Example reply from a 2020 Kia Stinger.
Bits 376 to 391 of the reply, 16 bits. The bytes are in little-endian order.
0x0000 = 0 → (0 × 4 ÷ 1000) = 0 ms
- Formula
(val × 4 ÷ 1000)- Range
- 0 to 262.14 ms
- Unit
- ms
Confirmed for 2020. In testing for 2018 to 2019, 2021 to 2023.
Emission relevant misfires total all cylinders STINGER_EMISSION_RELEVANT_MISFIRES_TOTAL_ALL_CYLINDERS
- Request
22 E0 0D - Service 22
DID E00D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 432 to 447 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2018 to 2019, 2021, 2023. Not supported for 2020, 2022.
Emission relevant misfires total, cylinder 1 STINGER_EMIS_MIS_TOT_1Confirmed
- Request
22 E0 1D - Service 22
DID E01D - Module
7E0 → 7E8 - Every
1 s - Testing for 2018 to 2019, 2021 to 2023
Example reply from a 2020 Kia Stinger.
Bits 32 to 47 of the reply, 16 bits. The bytes are in little-endian order.
0x0000 = 0 → 0
- Formula
val- Range
- 0 to 65535
- Unit
- Number
Confirmed for 2020. In testing for 2018 to 2019, 2021 to 2023.
Emission relevant misfires total, cylinder 1 STINGER_EMISSION_RELEVANT_MISFIRES_TOTAL_C1
- Request
22 E0 0D - Service 22
DID E00D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 176 to 191 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2018 to 2019, 2021, 2023. Not supported for 2020, 2022.
Emission relevant misfires total, cylinder 2 STINGER_EMIS_MIS_TOT_2Confirmed
- Request
22 E0 1D - Service 22
DID E01D - Module
7E0 → 7E8 - Every
1 s - Testing for 2018 to 2019, 2021 to 2023
Example reply from a 2020 Kia Stinger.
Bits 48 to 63 of the reply, 16 bits. The bytes are in little-endian order.
0x0000 = 0 → 0
- Formula
val- Range
- 0 to 65535
- Unit
- Number
Confirmed for 2020. In testing for 2018 to 2019, 2021 to 2023.
Emission relevant misfires total, cylinder 2 STINGER_EMISSION_RELEVANT_MISFIRES_TOTAL_C2
- Request
22 E0 0D - Service 22
DID E00D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 192 to 207 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2018 to 2019, 2021, 2023. Not supported for 2020, 2022.
Emission relevant misfires total, cylinder 3 STINGER_EMIS_MIS_TOT_3Confirmed
- Request
22 E0 1D - Service 22
DID E01D - Module
7E0 → 7E8 - Every
1 s - Testing for 2018 to 2019, 2021 to 2023
Example reply from a 2020 Kia Stinger.
Bits 64 to 79 of the reply, 16 bits. The bytes are in little-endian order.
0x0000 = 0 → 0
- Formula
val- Range
- 0 to 65535
- Unit
- Number
Confirmed for 2020. In testing for 2018 to 2019, 2021 to 2023.
Emission relevant misfires total, cylinder 3 STINGER_EMISSION_RELEVANT_MISFIRES_TOTAL_C3
- Request
22 E0 0D - Service 22
DID E00D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 208 to 223 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2018 to 2019, 2021, 2023. Not supported for 2020, 2022.
Emission relevant misfires total, cylinder 4 STINGER_EMIS_MIS_TOT_4Confirmed
- Request
22 E0 1D - Service 22
DID E01D - Module
7E0 → 7E8 - Every
1 s - Testing for 2018 to 2019, 2021 to 2023
Example reply from a 2020 Kia Stinger.
Bits 80 to 95 of the reply, 16 bits. The bytes are in little-endian order.
0x0000 = 0 → 0
- Formula
val- Range
- 0 to 65535
- Unit
- Number
Confirmed for 2020. In testing for 2018 to 2019, 2021 to 2023.
Emission relevant misfires total, cylinder 4 STINGER_EMISSION_RELEVANT_MISFIRES_TOTAL_C4
- Request
22 E0 0D - Service 22
DID E00D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 224 to 239 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2018 to 2019, 2021, 2023. Not supported for 2020, 2022.
Engine coolant temperature ECTSAE J1979Confirmed
Your engine temperature must operate within a certain temperature range to operate efficiently and safely. If it runs too hot, then your engine could be permanently damaged. If it runs too cold, then your engine will use more fuel than necessary.
Pelican can show this parameter as the engine coolant temperature.
- Request
01 05 - Service 01
PID 05 - Module
7E0 → 7E8 - Every
500 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2018 to 2022. Supported for 2023.
Engine Friction - Percent Torque TQ_FRSAE J1979Confirmed
- Request
01 8E - Service 01
PID 8E - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 125)- Range
- -125 to 130 %
- Unit
- %
Confirmed for 2020.
Engine oil temperature STINGER_EOTConfirmed
- Request
22 E0 01 - Service 22
DID E001 - Module
7E0 → 7E8 - Every
2 s
Example reply from a 2023 Kia Stinger.
Bits 272 to 279 of the reply, 8 bits.
0x81 = 129 → (129 ÷ 1.3333 − 48) = 48.752419 °C
- Formula
(val ÷ 1.3333 − 48)- Range
- 0 to 143 °C
- Unit
- °C
Confirmed for 2018 to 2023.
Engine oil temperature STINGER_EOT_7E0
- Request
22 ED 07 - Service 22
DID ED07 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 152 to 159 of the reply, 8 bits.
- Formula
(val × 0.7843 − 50)- Range
- -50 to 149.9965 °C
- Unit
- °C
In testing for 2018 to 2019, 2021 to 2023. Not supported for 2020.
Engine oil temperature STINGER_EOT_V2Confirmed
- Request
22 ED 02 - Service 22
DID ED02 - Module
7E0 → 7E8 - Every
5 s - Testing for 2018 to 2019, 2021 to 2023
Example reply from a 2020 Kia Stinger.
Bits 184 to 191 of the reply, 8 bits.
0x62 = 98 → (98 − 4) = 94 °C
- Formula
(val − 4)- Range
- -4 to 251 °C
- Unit
- °C
Confirmed for 2020. Not supported for 2018 to 2019, 2021 to 2023.
Engine reference torque TQ_REFSAE J1979Confirmed
- Request
01 63 - Service 01
PID 63 - Module
7E0 → 7E8 - Every
86400 s
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 N·m
- Unit
- N·m
Confirmed for 2020.
Engine RPM RPMSAE J1979Confirmed
- Request
01 0C - Service 01
PID 0C - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4)- Range
- 0 to 16383.75 rpm
- Unit
- rpm
Confirmed for 2018, 2020. Supported for 2019, 2021 to 2023.
Engine RPM STINGER_RPM
- Request
21 C0 - Service 21
PID C0 - Module
7E5 - Every
250 ms - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
(val ÷ 4)- Range
- 0 to 16383.75 rpm
- Unit
- rpm
In testing for 2018, 2021. Not supported for 2019 to 2020, 2022 to 2023.
Engine, actual torque STINGER_ENG_ACT_TQ
- Request
22 ED 01 - Service 22
DID ED01 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 240 to 247 of the reply, 8 bits.
- Formula
(val × 2.3529)- Range
- 0 to 599.9895 N·m
- Unit
- N·m
In testing for 2018 to 2019, 2021 to 2023. Not supported for 2020.
Evap system vapor pressure EVAP_VPSAE J1979Confirmed
The pressure signal is normally obtained from a sensor located in the fuel tank or a sensor in an evaporative system vapor line.
- Request
01 32 - Service 01
PID 32 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 4000)- Range
- -8192 to 8191.75 kPa
- Unit
- kPa
Confirmed for 2018, 2020. Supported for 2019, 2022 to 2023.
Exhaust gas temperature STINGER_EXHAUST_GAS_T
- Request
21 03 - Service 21
PID 03 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 368 to 375 of the reply, 8 bits.
- Formula
(val × 4.709803922 + 99)- Range
- 99 to 1300 °C
- Unit
- °C
In testing for 2018, 2021. Not supported for 2019 to 2020, 2022 to 2023.
Exhaust temperature 1, upstream of oxidation catalyst STINGER_EXH_T_1_UP_OXICAT
- Request
22 ED 03 - Service 22
DID ED03 - Module
7E0 → 7E8 - Every
30 s - Testing
Bits 296 to 303 of the reply, 8 bits.
- Formula
(val × 4.7098 + 99)- Range
- 0 to 1299.999 °C
- Unit
- °C
In testing for 2018 to 2019, 2021 to 2023. Not supported for 2020.
Exhaust temperature 2, upstream of DPF STINGER_EXH_T_2_UP_DPF
- Request
22 ED 03 - Service 22
DID ED03 - Module
7E0 → 7E8 - Every
30 s - Testing
Bits 304 to 311 of the reply, 8 bits.
- Formula
(val × 4.7098 + 99)- Range
- 0 to 1299.999 °C
- Unit
- °C
In testing for 2018 to 2019, 2021 to 2023. Not supported for 2020.
Front left tire temperature STINGER_FL_TT
Pelican can show this parameter as the front left tire temperature.
- Request
21 06 - Service 21
PID 06 - Module
7D6 → 7DE - Every
15 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2018, 2021. Not supported for 2019 to 2020, 2022 to 2023.
Front right tire temperature STINGER_FR_TT
Pelican can show this parameter as the front right tire temperature.
- Request
21 06 - Service 21
PID 06 - Module
7D6 → 7DE - Every
15 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2018, 2021. Not supported for 2019 to 2020, 2022 to 2023.
Fuel rail pressure (absolute) FRP_ABSSAE J1979Confirmed
Fuel rail pressure at the engine when the reading is referenced to atmosphere (gage pressure).
- Request
01 59 - Service 01
PID 59 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 10)- Range
- 0 to 655350 kPa
- Unit
- kPa
Confirmed for 2018, 2020.
Gasoline direct injection time bank a, 1 STINGER_GDI_IT_A1
- Request
22 E0 05 - Service 22
DID E005 - Module
7E0 → 7E8 - Every
2 s - Testing for 2018 to 2019, 2021, 2023
Bits 224 to 239 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 ms
- Unit
- ms
In testing for 2018 to 2019, 2021, 2023. Supported for 2020, 2022.
Gasoline direct injection time bank a, 2 STINGER_GDI_IT_A2
- Request
22 E0 05 - Service 22
DID E005 - Module
7E0 → 7E8 - Every
2 s - Testing for 2018 to 2019, 2021, 2023
Bits 240 to 255 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 ms
- Unit
- ms
In testing for 2018 to 2019, 2021, 2023. Supported for 2020, 2022.
Gasoline direct injection time bank a, 3 STINGER_GDI_IT_A3
- Request
22 E0 05 - Service 22
DID E005 - Module
7E0 → 7E8 - Every
2 s - Testing for 2018 to 2019, 2021, 2023
Bits 256 to 271 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 ms
- Unit
- ms
In testing for 2018 to 2019, 2021, 2023. Supported for 2020, 2022.
Gasoline direct injection time bank a, 4 STINGER_GDI_IT_A4
- Request
22 E0 05 - Service 22
DID E005 - Module
7E0 → 7E8 - Every
2 s - Testing for 2018 to 2019, 2021, 2023
Bits 272 to 287 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 ms
- Unit
- ms
In testing for 2018 to 2019, 2021, 2023. Supported for 2020, 2022.
Gasoline direct injection time bank b, 1 STINGER_GDI_IT_B1
- Request
22 E0 05 - Service 22
DID E005 - Module
7E0 → 7E8 - Every
2 s - Testing for 2018 to 2019, 2021, 2023
Bits 352 to 367 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 ms
- Unit
- ms
In testing for 2018 to 2019, 2021, 2023. Supported for 2020, 2022.
Gasoline direct injection time bank b, 2 STINGER_GDI_IT_B2
- Request
22 E0 05 - Service 22
DID E005 - Module
7E0 → 7E8 - Every
2 s - Testing for 2018 to 2019, 2021, 2023
Bits 368 to 383 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 ms
- Unit
- ms
In testing for 2018 to 2019, 2021, 2023. Supported for 2020, 2022.
Gasoline direct injection time bank b, 3 STINGER_GDI_IT_B3
- Request
22 E0 05 - Service 22
DID E005 - Module
7E0 → 7E8 - Every
2 s - Testing for 2018 to 2019, 2021, 2023
Bits 384 to 399 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 ms
- Unit
- ms
In testing for 2018 to 2019, 2021, 2023. Supported for 2020, 2022.
Gasoline direct injection time bank b, 4 STINGER_GDI_IT_B4
- Request
22 E0 05 - Service 22
DID E005 - Module
7E0 → 7E8 - Every
2 s - Testing for 2018 to 2019, 2021, 2023
Bits 400 to 415 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 ms
- Unit
- ms
In testing for 2018 to 2019, 2021, 2023. Supported for 2020, 2022.
Heat STINGER_HEAT
- Request
21 C0 - Service 21
PID C0 - Module
7E5 - Every
250 ms - Testing
Bits 96 to 103 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 °C
- Unit
- °C
In testing for 2018, 2021. Not supported for 2019 to 2020, 2022 to 2023.
Injection duration cylinder 1 STINGER_INJ_DUR_1Confirmed
- Request
22 E0 02 - Service 22
DID E002 - Module
7E0 → 7E8 - Every
5 s
Bits 176 to 191 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val ÷ 1220.7)- Range
- 0 to 53.68 s
- Unit
- s
Confirmed for 2018 to 2023.
Injection duration cylinder 2 STINGER_INJ_DUR_2Confirmed
- Request
22 E0 02 - Service 22
DID E002 - Module
7E0 → 7E8 - Every
5 s
Bits 192 to 207 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val ÷ 1220.7)- Range
- 0 to 53.68 s
- Unit
- s
Confirmed for 2018 to 2023.
Injection duration cylinder 3 STINGER_INJ_DUR_3Confirmed
- Request
22 E0 02 - Service 22
DID E002 - Module
7E0 → 7E8 - Every
5 s
Bits 208 to 223 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val ÷ 1220.7)- Range
- 0 to 53.68 s
- Unit
- s
Confirmed for 2018 to 2023.
Injection duration cylinder 4 STINGER_INJ_DUR_4Confirmed
- Request
22 E0 02 - Service 22
DID E002 - Module
7E0 → 7E8 - Every
5 s
Bits 224 to 239 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val ÷ 1220.7)- Range
- 0 to 53.68 s
- Unit
- s
Confirmed for 2018 to 2023.
Injection duration cylinder 5 STINGER_INJ_DUR_5Confirmed
- Request
22 E0 02 - Service 22
DID E002 - Module
7E0 → 7E8 - Every
5 s
Example reply from a 2023 Kia Stinger.
Bits 240 to 255 of the reply, 16 bits. The bytes are in little-endian order.
0x0000 = 0 → (0 ÷ 1220.7) = 0 s
- Formula
(val ÷ 1220.7)- Range
- 0 to 53.68 s
- Unit
- s
Confirmed for 2018 to 2023.
Injection duration cylinder 6 STINGER_INJ_DUR_6Confirmed
- Request
22 E0 02 - Service 22
DID E002 - Module
7E0 → 7E8 - Every
5 s
Example reply from a 2023 Kia Stinger.
Bits 256 to 271 of the reply, 16 bits. The bytes are in little-endian order.
0x0000 = 0 → (0 ÷ 1220.7) = 0 s
- Formula
(val ÷ 1220.7)- Range
- 0 to 53.68 s
- Unit
- s
Confirmed for 2018 to 2023.
Intake air temperature IATSAE J1979Confirmed
- Request
01 0F - Service 01
PID 0F - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2018, 2020. Supported for 2019, 2021 to 2023.
Intake air temperature STINGER_IATConfirmed
- Request
22 E0 01 - Service 22
DID E001 - Module
7E0 → 7E8 - Every
2 s
Example reply from a 2023 Kia Stinger.
Bits 264 to 271 of the reply, 8 bits.
0x53 = 83 → (83 ÷ 1.3333 − 48) = 14.251556 °C
- Formula
(val ÷ 1.3333 − 48)- Range
- 0 to 143 °C
- Unit
- °C
Confirmed for 2018 to 2023.
Intake camshaft position actual STINGER_INTAKE_CAMSHAFT_POSITION_ACTUAL
- Request
21 17 - Service 21
PID 17 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 40 to 55 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
(val ÷ 128)- Range
- -256 to 255 °
- Unit
- °
In testing for 2018, 2021. Not supported for 2019 to 2020, 2022 to 2023.
Intake camshaft position commanded STINGER_INTAKE_CAMSHAFT_POSITION_COMMANDED
- Request
21 17 - Service 21
PID 17 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 32 to 39 of the reply, 8 bits. The value is signed.
- Formula
(val ÷ 2)- Range
- -64 to 63.5 °
- Unit
- °
In testing for 2018, 2021. Not supported for 2019 to 2020, 2022 to 2023.
Intake manifold absolute pressure MAPSAE J1979Confirmed
- Request
01 0B - Service 01
PID 0B - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 kPa
- Unit
- kPa
Confirmed for 2018, 2020. Supported for 2019, 2021 to 2023.
Knock learn cylinder 1 STINGER_KNOCK_LEARN_1Confirmed
- Request
22 E0 0A - Service 22
DID E00A - Module
7E0 → 7E8 - Every
1 s
Example reply from a 2022 Kia Stinger.
Bits 160 to 167 of the reply, 8 bits. The value is signed.
0x00 = 0 → (0 ÷ 5) = 0 °
- Formula
(val ÷ 5)- Range
- -25.6 to 25.4 °
- Unit
- °
Confirmed for 2019 to 2022. Supported for 2018, 2023.
Knock learn cylinder 2 STINGER_KNOCK_LEARN_2
- Request
22 E0 0A - Service 22
DID E00A - Module
7E0 → 7E8 - Every
1 s
Bits 168 to 175 of the reply, 8 bits. The value is signed.
- Formula
(val ÷ 5)- Range
- -25.6 to 25.4 °
- Unit
- °
Supported for 2018 to 2023.
Knock learn cylinder 3 STINGER_KNOCK_LEARN_3
- Request
22 E0 0A - Service 22
DID E00A - Module
7E0 → 7E8 - Every
1 s
Bits 176 to 183 of the reply, 8 bits. The value is signed.
- Formula
(val ÷ 5)- Range
- -25.6 to 25.4 °
- Unit
- °
Supported for 2018 to 2023.
Knock learn cylinder 4 STINGER_KNOCK_LEARN_4
- Request
22 E0 0A - Service 22
DID E00A - Module
7E0 → 7E8 - Every
1 s
Bits 184 to 191 of the reply, 8 bits. The value is signed.
- Formula
(val ÷ 5)- Range
- -25.6 to 25.4 °
- Unit
- °
Supported for 2018 to 2023.
Knock retard cylinder #1 STINGER_KNOCK_RETARD_CYLINDER_1
- Request
21 16 - Service 21
PID 16 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 96 to 103 of the reply, 8 bits.
- Formula
(val × 0.75)- Range
- 0 to 191.25 °
- Unit
- °
In testing for 2018 to 2019, 2021. Not supported for 2020, 2022 to 2023.
Knock retard cylinder #2 STINGER_KNOCK_RETARD_CYLINDER_2
- Request
21 16 - Service 21
PID 16 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 104 to 111 of the reply, 8 bits.
- Formula
(val × 0.75)- Range
- 0 to 191.25 °
- Unit
- °
In testing for 2018 to 2019, 2021. Not supported for 2020, 2022 to 2023.
Knock retard cylinder #3 STINGER_KNOCK_RETARD_CYLINDER_3
- Request
21 16 - Service 21
PID 16 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 112 to 119 of the reply, 8 bits.
- Formula
(val × 0.75)- Range
- 0 to 191.25 °
- Unit
- °
In testing for 2018 to 2019, 2021. Not supported for 2020, 2022 to 2023.
Knock retard cylinder #4 STINGER_KNOCK_RETARD_CYLINDER_4
- Request
21 16 - Service 21
PID 16 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 120 to 127 of the reply, 8 bits.
- Formula
(val × 0.75)- Range
- 0 to 191.25 °
- Unit
- °
In testing for 2018 to 2019, 2021. Not supported for 2020, 2022 to 2023.
Knock retard cylinder 1 STINGER_KNOCK_RETARD_1Confirmed
- Request
22 E0 0A - Service 22
DID E00A - Module
7E0 → 7E8 - Every
1 s
Example reply from a 2023 Kia Stinger.
Bits 96 to 103 of the reply, 8 bits. The value is signed.
0xB2 = -78 → (-78 ÷ 5) = -15.6 °
- Formula
(val ÷ 5)- Range
- -25.6 to 25.4 °
- Unit
- °
Confirmed for 2018 to 2023.
Knock retard cylinder 1, alternate STINGER_KNOCK_RETARD_1_E019Confirmed
- Request
22 E0 19 - Service 22
DID E019 - Module
7E0 → 7E8 - Every
1 s - Testing for 2018, 2021
Example reply from a 2023 Kia Stinger.
Bits 168 to 175 of the reply, 8 bits.
0x00 = 0 → (0 × 0.75 − 191.25) = -191.25 °
- Formula
(val × 0.75 − 191.25)- Range
- -191.25 to 0 °
- Unit
- °
Confirmed for 2019 to 2020, 2022 to 2023. In testing for 2018, 2021.
Knock retard cylinder 2 STINGER_KNOCK_RETARD_2Confirmed
- Request
22 E0 0A - Service 22
DID E00A - Module
7E0 → 7E8 - Every
1 s
Example reply from a 2023 Kia Stinger.
Bits 104 to 111 of the reply, 8 bits. The value is signed.
0x00 = 0 → (0 ÷ 5) = 0 °
- Formula
(val ÷ 5)- Range
- -25.6 to 25.4 °
- Unit
- °
Confirmed for 2018 to 2023.
Knock retard cylinder 2, alternate STINGER_KNOCK_RETARD_2_E019Confirmed
- Request
22 E0 19 - Service 22
DID E019 - Module
7E0 → 7E8 - Every
1 s - Testing for 2018, 2021
Example reply from a 2023 Kia Stinger.
Bits 176 to 183 of the reply, 8 bits.
0x00 = 0 → (0 × 0.75 − 191.25) = -191.25 °
- Formula
(val × 0.75 − 191.25)- Range
- -191.25 to 0 °
- Unit
- °
Confirmed for 2019 to 2020, 2022 to 2023. In testing for 2018, 2021.
Knock retard cylinder 3 STINGER_KNOCK_RETARD_3Confirmed
- Request
22 E0 0A - Service 22
DID E00A - Module
7E0 → 7E8 - Every
1 s
Example reply from a 2023 Kia Stinger.
Bits 112 to 119 of the reply, 8 bits. The value is signed.
0x00 = 0 → (0 ÷ 5) = 0 °
- Formula
(val ÷ 5)- Range
- -25.6 to 25.4 °
- Unit
- °
Confirmed for 2018 to 2023.
Knock retard cylinder 3, alternate STINGER_KNOCK_RETARD_3_E019Confirmed
- Request
22 E0 19 - Service 22
DID E019 - Module
7E0 → 7E8 - Every
1 s - Testing for 2018, 2021
Example reply from a 2023 Kia Stinger.
Bits 184 to 191 of the reply, 8 bits.
0x00 = 0 → (0 × 0.75 − 191.25) = -191.25 °
- Formula
(val × 0.75 − 191.25)- Range
- -191.25 to 0 °
- Unit
- °
Confirmed for 2019 to 2020, 2022 to 2023. In testing for 2018, 2021.
Knock retard cylinder 4 STINGER_KNOCK_RETARD_4Confirmed
- Request
22 E0 0A - Service 22
DID E00A - Module
7E0 → 7E8 - Every
1 s
Example reply from a 2023 Kia Stinger.
Bits 120 to 127 of the reply, 8 bits. The value is signed.
0xDF = -33 → (-33 ÷ 5) = -6.6 °
- Formula
(val ÷ 5)- Range
- -25.6 to 25.4 °
- Unit
- °
Confirmed for 2018 to 2023.
Knock retard cylinder 4, alternate STINGER_KNOCK_RETARD_4_E019Confirmed
- Request
22 E0 19 - Service 22
DID E019 - Module
7E0 → 7E8 - Every
1 s - Testing for 2018, 2021
Example reply from a 2023 Kia Stinger.
Bits 192 to 199 of the reply, 8 bits.
0x00 = 0 → (0 × 0.75 − 191.25) = -191.25 °
- Formula
(val × 0.75 − 191.25)- Range
- -191.25 to 0 °
- Unit
- °
Confirmed for 2019 to 2020, 2022 to 2023. In testing for 2018, 2021.
Lock switch STINGER_LOCK_SWITCH
- Request
21 C0 - Service 21
PID C0 - Module
7E5 - Every
250 ms - Testing
Bit 151 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2018, 2021. Not supported for 2019 to 2020, 2022 to 2023.
Long term fuel trim (bank 1) LONGFT1SAE J1979Confirmed
- Request
01 07 - Service 01
PID 07 - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 128 − 100)- Range
- -100 to 99.2 %
- Unit
- %
Confirmed for 2018, 2020. Supported for 2019, 2021 to 2023.
Long term fuel trim (bank 2) LONGFT2SAE J1979Confirmed
- Request
01 09 - Service 01
PID 09 - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 128 − 100)- Range
- -100 to 99.2 %
- Unit
- %
Confirmed for 2020. Supported for 2019, 2021 to 2022.
Long term secondary O2 sensor fuel trim (bank 1) LGSO2FT1SAE J1979Confirmed
- Request
01 56 - Service 01
PID 56 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 128 − 100)- Range
- -100 to 99.22 %
- Unit
- %
Confirmed for 2018, 2020.
Long term secondary O2 sensor fuel trim (bank 2) LGSO2FT2SAE J1979Confirmed
- Request
01 58 - Service 01
PID 58 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 128 − 100)- Range
- -100 to 99.22 %
- Unit
- %
Confirmed for 2020.
Main injection volume STINGER_MAIN_INJECTION_QTY
- Request
21 07 - Service 21
PID 07 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 96 to 103 of the reply, 8 bits.
- Formula
(val × 0.392156863)- Range
- 0 to 100 L
- Unit
- L
In testing for 2018, 2021. Not supported for 2019 to 2020, 2022 to 2023.
Malfunction indicator STINGER_MALFUNCTION_INDICATOR
- Request
21 C0 - Service 21
PID C0 - Module
7E5 - Every
250 ms - Testing
Bit 175 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2018, 2021. Not supported for 2019 to 2020, 2022 to 2023.
Mass air flow rate STINGER_MAF_RATEConfirmed
- Request
22 E0 10 - Service 22
DID E010 - Module
7E0 → 7E8 - Every
1 s - Testing for 2018 to 2019, 2021 to 2023
Example reply from a 2020 Kia Stinger.
Bits 208 to 215 of the reply, 8 bits. The bytes are in little-endian order.
0x3E = 62 → (62 × 0.04239) = 2.62818
- Formula
(val × 0.04239)- Range
- 0 to 10.8
- Unit
- Raw value
Confirmed for 2020. In testing for 2018 to 2019, 2021 to 2023.
Misfire count #1 STINGER_MIS_1
- Request
21 01 - Service 21
PID 01 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 56 to 71 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2019. Not supported for 2018, 2020 to 2023.
Misfire count #2 STINGER_MIS_2
- Request
21 01 - Service 21
PID 01 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 72 to 87 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2019. Not supported for 2018, 2020 to 2023.
Misfire count #3 STINGER_MIS_3
- Request
21 01 - Service 21
PID 01 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 88 to 103 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2019. Not supported for 2018, 2020 to 2023.
Misfire count #4 STINGER_MIS_4
- Request
21 01 - Service 21
PID 01 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 104 to 119 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2019. Not supported for 2018, 2020 to 2023.
Misfires, current, cylinder 1 STINGER_MISFIRES_C1_CUR
- Request
22 E0 0D - Service 22
DID E00D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 48 to 63 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2018 to 2019, 2021, 2023. Not supported for 2020, 2022.
Misfires, current, cylinder 2 STINGER_MISFIRES_C2_CUR
- Request
22 E0 0D - Service 22
DID E00D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 64 to 79 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2018 to 2019, 2021, 2023. Not supported for 2020, 2022.
Misfires, current, cylinder 3 STINGER_MISFIRES_C3_CUR
- Request
22 E0 0D - Service 22
DID E00D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 80 to 95 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2018 to 2019, 2021, 2023. Not supported for 2020, 2022.
Misfires, current, cylinder 4 STINGER_MISFIRES_C4_CUR
- Request
22 E0 0D - Service 22
DID E00D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 96 to 111 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2018 to 2019, 2021, 2023. Not supported for 2020, 2022.
Motor-driven power steering current STINGER_MDPS_MOTOR_CURRENTConfirmed
- Request
22 01 01 - Service 22
DID 0101 - Module
7D4 → 7DC - Every
5 s - Testing for 2019
Example reply from a 2023 Kia Stinger.
Bits 88 to 95 of the reply, 8 bits. The value is signed.
0x00 = 0 → 0 A
- Formula
val- Range
- -128 to 127 A
- Unit
- A
Confirmed for 2018, 2020 to 2023. Not supported for 2019.
Oxygen sensor 1 bank 1 STINGER_OXYGEN_SENSOR_11
- Request
21 02 - Service 21
PID 02 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val × 0.00521 − 0.2)- Range
- -0.2 to 1.12 V
- Unit
- V
In testing for 2018, 2021. Not supported for 2019 to 2020, 2022 to 2023.
Oxygen sensor 2 bank 1 STINGER_OXYGEN_SENSOR_21
- Request
21 02 - Service 21
PID 02 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 48 to 55 of the reply, 8 bits.
- Formula
(val × 0.00521 − 0.2)- Range
- -0.2 to 1.12 V
- Unit
- V
In testing for 2018, 2021. Not supported for 2019 to 2020, 2022 to 2023.
Pilot injection volume STINGER_PILOT_INJECTION_QTY
- Request
21 07 - Service 21
PID 07 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 104 to 119 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 L
- Unit
- L
In testing for 2018, 2021. Not supported for 2019 to 2020, 2022 to 2023.
Post injection volume STINGER_POST_INJECTION_QTY
- Request
21 07 - Service 21
PID 07 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 128 to 143 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 L
- Unit
- L
In testing for 2018, 2021. Not supported for 2019 to 2020, 2022 to 2023.
Pressure sensor STINGER_PRESSURE_SENSOR
- Request
21 C0 - Service 21
PID C0 - Module
7E5 - Every
250 ms - Testing
Bits 176 to 183 of the reply, 8 bits.
- Formula
(val ÷ 4)- Range
- 0 to 63.75 bar
- Unit
- bar
In testing for 2018, 2021. Not supported for 2019 to 2020, 2022 to 2023.
Rear left tire temperature STINGER_RL_TT
Pelican can show this parameter as the rear left tire temperature.
- Request
21 06 - Service 21
PID 06 - Module
7D6 → 7DE - Every
15 s - Testing
Bits 72 to 79 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2018, 2021. Not supported for 2019 to 2020, 2022 to 2023.
Rear right tire temperature STINGER_RR_TT
Pelican can show this parameter as the rear right tire temperature.
- Request
21 06 - Service 21
PID 06 - Module
7D6 → 7DE - Every
15 s - Testing
Bits 104 to 111 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2018, 2021. Not supported for 2019 to 2020, 2022 to 2023.
Requested torque STINGER_REQUESTED_TORQUE
- Request
21 14 - Service 21
PID 14 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 176 to 191 of the reply, 16 bits.
- Formula
(val × 0.001526)- Range
- 0 to 100 %
- Unit
- %
In testing for 2018 to 2019, 2021. Not supported for 2020, 2022 to 2023.
Short term fuel trim (bank 1) SHRTFT1SAE J1979Confirmed
Correction being used by the closed-loop fuel algorithm.
Pelican can show this parameter as the short term fuel trim.
- Request
01 06 - Service 01
PID 06 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 128 − 100)- Range
- -100 to 99.2 %
- Unit
- %
Confirmed for 2018, 2020, 2023. Supported for 2019, 2021 to 2022.
Short term fuel trim (bank 2) SHRTFT2SAE J1979Confirmed
Correction being used by the closed-loop fuel algorithm.
Pelican can show this parameter as the short term fuel trim.
- Request
01 08 - Service 01
PID 08 - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 128 − 100)- Range
- -100 to 99.2 %
- Unit
- %
Confirmed for 2020. Supported for 2019, 2021 to 2022.
Short term secondary O2 sensor fuel trim (bank 1) STSO2FT1SAE J1979Confirmed
- Request
01 55 - Service 01
PID 55 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 128 − 100)- Range
- -100 to 99.22 %
- Unit
- %
Confirmed for 2018, 2020.
Short term secondary O2 sensor fuel trim (bank 2) STSO2FT2SAE J1979Confirmed
- Request
01 57 - Service 01
PID 57 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 128 − 100)- Range
- -100 to 99.22 %
- Unit
- %
Confirmed for 2020.
Throttle position #1 STINGER_THROTTLE_POSITION__1
- Request
21 14 - Service 21
PID 14 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 48 to 63 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
(val × 0.0244140625)- Range
- -800 to 799 %
- Unit
- %
In testing for 2018 to 2019, 2021. Not supported for 2020, 2022 to 2023.
Throttle position #2 STINGER_THROTTLE_POSITION__2
- Request
21 14 - Service 21
PID 14 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 64 to 79 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
(val × 0.0244140625)- Range
- -800 to 799 %
- Unit
- %
In testing for 2018 to 2019, 2021. Not supported for 2020, 2022 to 2023.
Timing advance SPARKADVSAE J1979Confirmed
Ignition timing spark advance for the first cylinder. Measured in degrees before dead center. Minus is degrees before dead center, positive is degrees after.
- Request
01 0E - Service 01
PID 0E - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 2 − 64)- Range
- -64 to 63.5 °
- Unit
- °
Confirmed for 2018, 2020. Supported for 2019, 2021 to 2023.
Timing advance #1 STINGER_TIMING_ADVANCE_1
- Request
21 13 - Service 21
PID 13 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 32 to 39 of the reply, 8 bits. The value is signed.
- Formula
(val × 0.75)- Range
- -96 to 95.25 °
- Unit
- °
In testing for 2018 to 2019, 2021. Not supported for 2020, 2022 to 2023.
Timing advance #2 STINGER_TIMING_ADVANCE_2
- Request
21 13 - Service 21
PID 13 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 40 to 47 of the reply, 8 bits. The value is signed.
- Formula
(val × 0.75)- Range
- -96 to 95.25 °
- Unit
- °
In testing for 2018 to 2019, 2021. Not supported for 2020, 2022 to 2023.
Timing advance #3 STINGER_TIMING_ADVANCE_3
- Request
21 13 - Service 21
PID 13 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 48 to 55 of the reply, 8 bits. The value is signed.
- Formula
(val × 0.75)- Range
- -96 to 95.25 °
- Unit
- °
In testing for 2018 to 2019, 2021. Not supported for 2020, 2022 to 2023.
Timing advance #4 STINGER_TIMING_ADVANCE_4
- Request
21 13 - Service 21
PID 13 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 56 to 63 of the reply, 8 bits. The value is signed.
- Formula
(val × 0.75)- Range
- -96 to 95.25 °
- Unit
- °
In testing for 2018 to 2019, 2021. Not supported for 2020, 2022 to 2023.
Torque converter slip STINGER_TORQUE_CONVERTER_SLIPConfirmed
- Request
22 01 A0 - Service 22
DID 01A0 - Module
7E1 → 7E9 - Every
250 ms - Testing for 2018, 2021
Example reply from a 2023 Kia Stinger.
Bits 128 to 143 of the reply, 16 bits.
0x0800 = 2048 → (2048 ÷ 4 − 512) = 0 rpm
- Formula
(val ÷ 4 − 512)- Range
- -512 to 15871.75 rpm
- Unit
- rpm
Confirmed for 2019 to 2020, 2022 to 2023. In testing for 2018, 2021.
Turbo boost gauge pressure STINGER_TURBO_BOOSTConfirmed
- Request
22 E0 21 - Service 22
DID E021 - Module
7E0 → 7E8 - Every
100 ms
Example reply from a 2023 Kia Stinger.
Bits 56 to 71 of the reply, 16 bits.
0x2C02 = 11266 → (11266 ÷ 831.556909 − 12) = 1.548081 psi
- Formula
(val ÷ 831.556909 − 12)- Range
- -10 to 66.81 psi
- Unit
- psi
Confirmed for 2018 to 2023.
Type of fuel currently being used by the vehicle FUEL_TYPSAE J1979Confirmed
- Request
01 51 - Service 01
PID 51 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
1 | GAS | Gasoline/petrol |
2 | METH | Methanol |
3 | ETH | Ethanol |
4 | DSL | Diesel |
5 | LPG | Liquefied petroleum gas |
6 | CNG | Compressed natural gas |
7 | PROP | Propane |
8 | ELEC | Battery/electric |
9 | BI_GAS | Bi-fuel vehicle using gasoline/petrol |
10 | BI_METH | Bi-fuel vehicle using methanol |
11 | BI_ETH | Bi-fuel vehicle using ethanol |
12 | BI_LPG | Bi-fuel vehicle using LPG |
13 | BI_CNG | Bi-fuel vehicle using CNG |
14 | BI_PROP | Bi-fuel vehicle using propane |
15 | BI_ELEC | Bi-fuel vehicle using battery |
16 | BI_MIX | Bi-fuel vehicle using battery and combustion engine for propulsion |
17 | HYB_GAS | Hybrid vehicle using gasoline engine for propulsion |
18 | HYB_ETH | Hybrid vehicle using gasoline engine on ethanol for propulsion |
19 | HYB_DSL | Hybrid vehicle using diesel engine for propulsion |
20 | HYB_ELEC | Hybrid vehicle using battery for propulsion |
21 | HYB_MIX | Hybrid vehicle using battery and combustion engine for propulsion |
22 | HYB_REG | Hybrid vehicle in regeneration mode |
23 | BI_DSL | Bi-fuel vehicle using diesel |
24 | BI_NG | Bi-fuel vehicle using natural gas |
25 | BI_DSL | Bi-fuel vehicle using diesel |
26 | NG | Natural gas |
27 | DSL_CNG | Dual fuel vehicle using diesel and CNG |
28 | DSL_LNG | Dual fuel vehicle using diesel and LNG |
29 | FC_H2 | Fuel cell utilizing hydrogen |
30 | HICE_HHO | Hydrogen Internal Combustion Engine |
31 | KERO | Kerosene |
32 | HFO | Heavy Fuel Oil |
Confirmed for 2018, 2020.
Variable valve timing temperature STINGER_CVVT_T
Continuously variable valve timing temperature.
- Request
21 18 - Service 21
PID 18 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 272 to 279 of the reply, 8 bits.
- Formula
(val − 48)- Range
- -48 to 207 °C
- Unit
- °C
In testing for 2019, 2021. Not supported for 2018, 2020, 2022 to 2023.
Waste gate duty STINGER_WG_DUTYConfirmed
- Request
22 E0 21 - Service 22
DID E021 - Module
7E0 → 7E8 - Every
100 ms
Example reply from a 2023 Kia Stinger.
Bits 408 to 423 of the reply, 16 bits.
0x1E70 = 7792 → (7792 × 200 ÷ 65535) = 23.77966 %
- Formula
(val × 200 ÷ 65535)- Range
- 0 to 200 %
- Unit
- %
Confirmed for 2018 to 2023.
Waste gate position STINGER_WG_POSITIONConfirmed
- Request
22 E0 21 - Service 22
DID E021 - Module
7E0 → 7E8 - Every
100 ms
Example reply from a 2023 Kia Stinger.
Bits 424 to 439 of the reply, 16 bits.
0x0369 = 873 → (873 × 400 ÷ 65535) = 5.32845 %
- Formula
(val × 400 ÷ 65535)- Range
- 0 to 400 %
- Unit
- %
Confirmed for 2018 to 2023.
Waste gate set point STINGER_WG_SETPOINTConfirmed
- Request
22 E0 21 - Service 22
DID E021 - Module
7E0 → 7E8 - Every
100 ms
Example reply from a 2023 Kia Stinger.
Bits 440 to 455 of the reply, 16 bits.
0x3C60 = 15456 → (15456 × 400 ÷ 65535) = 94.337377 %
- Formula
(val × 400 ÷ 65535)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2018 to 2023.
Waste gate voltage STINGER_WG_VOLTAGEConfirmed
- Request
22 E0 21 - Service 22
DID E021 - Module
7E0 → 7E8 - Every
100 ms
Bits 392 to 407 of the reply, 16 bits.
- Formula
(val × 10 ÷ 65535)- Range
- 0 to 10 V
- Unit
- V
Confirmed for 2018 to 2023.
Engine › Misfires
Emission-relevant misfires, cylinder #1 STINGER_MIS_CNT_EMIS_1
- Request
21 0D - Service 21
PID 0D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 48 to 63 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2018, 2021. Not supported for 2019 to 2020, 2022 to 2023.
Emission-relevant misfires, cylinder #2 STINGER_MIS_CNT_EMIS_2
- Request
21 0D - Service 21
PID 0D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 64 to 79 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2018, 2021. Not supported for 2019 to 2020, 2022 to 2023.
Emission-relevant misfires, cylinder #3 STINGER_MIS_CNT_EMIS_3
- Request
21 0D - Service 21
PID 0D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 80 to 95 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2018, 2021. Not supported for 2019 to 2020, 2022 to 2023.
Emission-relevant misfires, cylinder #4 STINGER_MIS_CNT_EMIS_4
- Request
21 0D - Service 21
PID 0D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 96 to 111 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2018, 2021. Not supported for 2019 to 2020, 2022 to 2023.
Misfires harmful for catalyst cylinder 1 STINGER_MIS_CAT_1
- Request
21 1D - Service 21
PID 1D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 160 to 175 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2018, 2021. Not supported for 2019 to 2020, 2022 to 2023.
Misfires harmful for catalyst cylinder 2 STINGER_MIS_CAT_2
- Request
21 1D - Service 21
PID 1D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 176 to 191 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2018, 2021. Not supported for 2019 to 2020, 2022 to 2023.
Misfires harmful for catalyst cylinder 3 STINGER_MIS_CAT_3
- Request
21 1D - Service 21
PID 1D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 192 to 207 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2018, 2021. Not supported for 2019 to 2020, 2022 to 2023.
Misfires harmful for catalyst cylinder 4 STINGER_MIS_CAT_4
- Request
21 1D - Service 21
PID 1D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 208 to 223 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2018, 2021. Not supported for 2019 to 2020, 2022 to 2023.
Misfires total counter, all cylinders STINGER_MIS_CNT_ALL
- Request
21 0D - Service 21
PID 0D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 432 to 447 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2018, 2021. Not supported for 2019 to 2020, 2022 to 2023.
Misfires total counter, cylinder #1 STINGER_MIS_CNT_1
- Request
21 0D - Service 21
PID 0D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 176 to 191 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2018, 2021. Not supported for 2019 to 2020, 2022 to 2023.
Misfires total counter, cylinder #2 STINGER_MIS_CNT_2
- Request
21 0D - Service 21
PID 0D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 192 to 207 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2018, 2021. Not supported for 2019 to 2020, 2022 to 2023.
Misfires total counter, cylinder #3 STINGER_MIS_CNT_3
- Request
21 0D - Service 21
PID 0D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 208 to 223 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2018, 2021. Not supported for 2019 to 2020, 2022 to 2023.
Misfires total counter, cylinder #4 STINGER_MIS_CNT_4
- Request
21 0D - Service 21
PID 0D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 224 to 239 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2018, 2021. Not supported for 2019 to 2020, 2022 to 2023.
Misfires, cylinder 1 STINGER_MIS_1_7E0
- Request
21 1D - Service 21
PID 1D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 32 to 47 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2018, 2021. Not supported for 2019 to 2020, 2022 to 2023.
Misfires, cylinder 2 STINGER_MIS_2_7E0
- Request
21 1D - Service 21
PID 1D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 48 to 63 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2018, 2021. Not supported for 2019 to 2020, 2022 to 2023.
Misfires, cylinder 3 STINGER_MIS_3_7E0
- Request
21 1D - Service 21
PID 1D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 64 to 79 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2018, 2021. Not supported for 2019 to 2020, 2022 to 2023.
Misfires, cylinder 4 STINGER_MIS_4_7E0
- Request
21 1D - Service 21
PID 1D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 80 to 95 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2018, 2021. Not supported for 2019 to 2020, 2022 to 2023.
Engine › OxygenSensors
02S Bank 1, Sensor 1 present O2S11_EXISTSSAE J1979Confirmed
- Request
01 13 - Service 01
PID 13 - Module
7E0 → 7E8 - Every
3600 s
Bit 7 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2020. Supported for 2018 to 2019, 2021 to 2023.
02S Bank 1, Sensor 2 present O2S12_EXISTSSAE J1979Confirmed
- Request
01 13 - Service 01
PID 13 - Module
7E0 → 7E8 - Every
3600 s
Bit 6 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2020. Supported for 2018 to 2019, 2021 to 2023.
02S Bank 1, Sensor 3 present O2S13_EXISTSSAE J1979Confirmed
- Request
01 13 - Service 01
PID 13 - Module
7E0 → 7E8 - Every
3600 s
Bit 5 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2020. Supported for 2018 to 2019, 2021 to 2023.
02S Bank 1, Sensor 4 present O2S14_EXISTSSAE J1979Confirmed
- Request
01 13 - Service 01
PID 13 - Module
7E0 → 7E8 - Every
3600 s
Bit 4 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2020. Supported for 2018 to 2019, 2021 to 2023.
02S Bank 2, Sensor 1 present O2S21_EXISTSSAE J1979Confirmed
- Request
01 13 - Service 01
PID 13 - Module
7E0 → 7E8 - Every
3600 s
Bit 3 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2020. Supported for 2018 to 2019, 2021 to 2023.
02S Bank 2, Sensor 2 present O2S22_EXISTSSAE J1979Confirmed
- Request
01 13 - Service 01
PID 13 - Module
7E0 → 7E8 - Every
3600 s
Bit 2 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2020. Supported for 2018 to 2019, 2021 to 2023.
02S Bank 2, Sensor 3 present O2S23_EXISTSSAE J1979Confirmed
- Request
01 13 - Service 01
PID 13 - Module
7E0 → 7E8 - Every
3600 s
Bit 1 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2020. Supported for 2018 to 2019, 2021 to 2023.
02S Bank 2, Sensor 4 present O2S24_EXISTSSAE J1979Confirmed
- Request
01 13 - Service 01
PID 13 - Module
7E0 → 7E8 - Every
3600 s
Bit 0 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2020. Supported for 2018 to 2019, 2021 to 2023.
Lambda value, Equivalence Ratio Bank 1, Sensor 1 LAMBDA11_CURRENTSAE J1979Confirmed
Pelican can show this parameter as the O2 lambda.
- Request
01 34 - Service 01
PID 34 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 32768)- Range
- 0 to 1.99
- Unit
- Number
Confirmed for 2019 to 2023.
O2S Output Voltage Bank 1, Sensor 2 O2S12SAE J1979Confirmed
- Request
01 15 - Service 01
PID 15 - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 200)- Range
- 0 to 1.275 V
- Unit
- V
Confirmed for 2020. Supported for 2018 to 2019, 2021 to 2023.
O2S Output Voltage Bank 2, Sensor 2 O2S22SAE J1979Confirmed
- Request
01 19 - Service 01
PID 19 - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 200)- Range
- 0 to 1.275 V
- Unit
- V
Confirmed for 2020. Supported for 2019, 2021 to 2022.
SHRTFT associated with O2S11 SHRTFT11SAE J1979Confirmed
- Request
01 14 - Service 01
PID 14 - Module
7E0 → 7E8 - Every
1 s
Bits 8 to 15 of the reply, 8 bits.
- Formula
(val × 100 ÷ 128 − 128)- Range
- -100 to 99.22 %
- Unit
- %
Confirmed for 2020. Supported for 2018 to 2019, 2021 to 2023.
SHRTFT associated with O2S22 SHRTFT22SAE J1979Confirmed
- Request
01 19 - Service 01
PID 19 - Module
7E0 → 7E8 - Every
1 s
Bits 8 to 15 of the reply, 8 bits.
- Formula
(val × 100 ÷ 128 − 128)- Range
- -100 to 99.22 %
- Unit
- %
Confirmed for 2020. Supported for 2019, 2021 to 2022.
Wide Range O2S Current, O2 Sensor Bank 1, Sensor 1 O2S11_CURRENTSAE J1979Confirmed
- Request
01 34 - Service 01
PID 34 - Module
7E0 → 7E8 - Every
250 ms
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val ÷ 256 − 128)- Range
- -128 to 127.996 mA
- Unit
- mA
Confirmed for 2019 to 2023.
Engine › Unknown
Unknown STINGER_22E004Confirmed
- Request
22 E0 04 - Service 22
DID E004 - Module
7E0 → 7E8 - Every
5 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100
- Unit
- Number
Confirmed for 2018 to 2023.