Kia Stinger

Battery parameters

The Kia Stinger has 20 battery parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

12V battery state of charge STINGER_BATTERY_SOCConfirmed

  • Request22 E0 01
  • Service 22DID E001
  • Module7E0 → 7E8
  • Every2 s

Example reply from a 2023 Kia Stinger.

Bits 48 to 55 of the reply, 8 bits.

0x43 = 67 → 67 %

Formula
val
Range
0 to 255 %
Unit
%

Confirmed for 2018 to 2023.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

12v battery charge STINGER_VPWR_V3

  • Request22 E0 04
  • Service 22DID E004
  • Module7E2 → 7EA
  • Every10 s
  • Testing for 2018, 2021 to 2023

Bits 152 to 159 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

Supported for 2019 to 2020. Not supported for 2018, 2021 to 2023.

12V battery state of charge STINGER_BATTERY_SOCConfirmed

  • Request22 E0 01
  • Service 22DID E001
  • Module7E0 → 7E8
  • Every2 s

Example reply from a 2023 Kia Stinger.

Bits 48 to 55 of the reply, 8 bits.

0x43 = 67 → 67 %

Formula
val
Range
0 to 255 %
Unit
%

Confirmed for 2018 to 2023.

Aux battery state of charge STINGER_AUX_SOC

  • Request22 E0 04
  • Service 22DID E004
  • Module7E0 → 7E8
  • Every5 s

Bits 320 to 327 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

Supported for 2018 to 2023.

Aux battery state of health STINGER_AUX_SOH

  • Request22 E0 04
  • Service 22DID E004
  • Module7E0 → 7E8
  • Every5 s

Bits 328 to 335 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

Supported for 2018 to 2023.

Available charge power STINGER_BMS_CHG_PWRConfirmed

  • Request22 01 01
  • Service 22DID 0101
  • Module7D4 → 7DC
  • Every5 s
  • Testing for 2019

Example reply from a 2023 Kia Stinger.

Bits 40 to 55 of the reply, 16 bits.

0x0000 = 0 → (0 ÷ 100) = 0 kW

Formula
(val ÷ 100)
Range
0 to 655.35 kW
Unit
kW

Confirmed for 2018, 2020 to 2023. Not supported for 2019.

Available discharge power STINGER_BMS_DISCHG_PWRConfirmed

  • Request22 01 01
  • Service 22DID 0101
  • Module7D4 → 7DC
  • Every5 s
  • Testing for 2019

Example reply from a 2023 Kia Stinger.

Bits 56 to 71 of the reply, 16 bits.

0x0000 = 0 → (0 ÷ 100) = 0 kW

Formula
(val ÷ 100)
Range
0 to 655.35 kW
Unit
kW

Confirmed for 2018, 2020 to 2023. Not supported for 2019.

Battery min temp STINGER_BMS_MIN_TEMP

  • Request22 01 01
  • Service 22DID 0101
  • Module7D4 → 7DC
  • Every5 s
  • Testing for 2019

Bits 120 to 127 of the reply, 8 bits. The value is signed.

Formula
val
Range
-40 to 80 °C
Unit
°C

Supported for 2018, 2020 to 2023. Not supported for 2019.

Battery mod 1 temp STINGER_BMS_MOD1_TEMP

  • Request22 01 01
  • Service 22DID 0101
  • Module7D4 → 7DC
  • Every5 s
  • Testing for 2019

Bits 128 to 135 of the reply, 8 bits. The value is signed.

Formula
val
Range
-40 to 80 °C
Unit
°C

Supported for 2018, 2020 to 2023. Not supported for 2019.

Battery mod 2 temp STINGER_BMS_MOD2_TEMP

  • Request22 01 01
  • Service 22DID 0101
  • Module7D4 → 7DC
  • Every5 s
  • Testing for 2019

Bits 136 to 143 of the reply, 8 bits. The value is signed.

Formula
val
Range
-40 to 80 °C
Unit
°C

Supported for 2018, 2020 to 2023. Not supported for 2019.

Battery mod 3 temp STINGER_BMS_MOD3_TEMP

  • Request22 01 01
  • Service 22DID 0101
  • Module7D4 → 7DC
  • Every5 s
  • Testing for 2019

Bits 144 to 151 of the reply, 8 bits. The value is signed.

Formula
val
Range
-40 to 80 °C
Unit
°C

Supported for 2018, 2020 to 2023. Not supported for 2019.

Battery mod 4 temp STINGER_BMS_MOD4_TEMP

  • Request22 01 01
  • Service 22DID 0101
  • Module7D4 → 7DC
  • Every5 s
  • Testing for 2019

Bits 152 to 159 of the reply, 8 bits. The value is signed.

Formula
val
Range
-40 to 80 °C
Unit
°C

Supported for 2018, 2020 to 2023. Not supported for 2019.

Battery voltage STINGER_BATTERY_VConfirmed

  • Request22 E0 01
  • Service 22DID E001
  • Module7E0 → 7E8
  • Every2 s

Example reply from a 2023 Kia Stinger.

Bits 32 to 39 of the reply, 8 bits.

0x65 = 101 → (101 × 17.37 ÷ 255) = 6.879882 V

Formula
(val × 17.37 ÷ 255)
Range
0 to 17.37 V
Unit
V

Confirmed for 2018 to 2023.

Battery voltage after ignition STINGER_BATTERY_V_AFTER_IGNITIONConfirmed

  • Request22 E0 01
  • Service 22DID E001
  • Module7E0 → 7E8
  • Every2 s

Example reply from a 2023 Kia Stinger.

Bits 40 to 47 of the reply, 8 bits.

0x6F = 111 → (111 × 17.37 ÷ 255) = 7.561059 V

Formula
(val × 17.37 ÷ 255)
Range
0 to 17.37 V
Unit
V

Confirmed for 2018 to 2023.

Control module voltage VPWRSAE J1979Confirmed

Power input to the OBD control module. VPWR is normally battery voltage, less any voltage drop in the circuit between the battery and the control module.

Pelican can show this parameter as the starter battery voltage.

  • Request01 42
  • Service 01PID 42
  • Module7E0 → 7E8
  • Every10 s

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65535 V
Unit
V

Confirmed for 2020 to 2022. Supported for 2018 to 2019, 2023.

Relative accelerator pedal position voltage STINGER_RELATIVE_ACCELERATOR_PEDAL_POSITION_VOLTAGE

  • Request21 14
  • Service 21PID 14
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 112 to 127 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
(val ÷ 5)
Range
-6553.6 to 6553.4 V
Unit
V

In testing for 2018 to 2019, 2021. Not supported for 2020, 2022 to 2023.

State of charge STINGER_BMS_SOCConfirmed

  • Request22 01 01
  • Service 22DID 0101
  • Module7D4 → 7DC
  • Every5 s
  • Testing for 2019

Bits 32 to 39 of the reply, 8 bits.

Formula
(val ÷ 2)
Range
0 to 100 %
Unit
%

Confirmed for 2018, 2020 to 2023. Not supported for 2019.

Supply voltage STINGER_SUPPLY_VOLTAGE

  • Request21 C0
  • Service 21PID C0
  • Module7E5
  • Every250 ms
  • Testing

Bits 64 to 71 of the reply, 8 bits.

Formula
(val ÷ 10)
Range
0 to 25.5 V
Unit
V

In testing for 2018, 2021. Not supported for 2019 to 2020, 2022 to 2023.

System voltage STINGER_SYSTEM_VOLTAGE

  • Request21 C0
  • Service 21PID C0
  • Module7E5
  • Every250 ms
  • Testing

Bits 72 to 79 of the reply, 8 bits.

Formula
(val ÷ 10)
Range
0 to 25.5 V
Unit
V

In testing for 2018, 2021. Not supported for 2019 to 2020, 2022 to 2023.

Throttle position sensor voltage #1 STINGER_THROTTLE_POSITION_SENSOR_VOLTAGE__1

  • Request21 14
  • Service 21PID 14
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 360 to 375 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val × 0.0012207031)
Range
0 to 79 V
Unit
V

In testing for 2018 to 2019, 2021. Not supported for 2020, 2022 to 2023.

Throttle position sensor voltage #2 STINGER_THROTTLE_POSITION_SENSOR_VOLTAGE__2

  • Request21 14
  • Service 21PID 14
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 80 to 95 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val × 0.0012207031)
Range
0 to 79 V
Unit
V

In testing for 2018 to 2019, 2021. Not supported for 2020, 2022 to 2023.

Keyboard shortcuts

jk/↓↑
Move down or up through a list or a grid.
hl/←→
Move across a row or between cards.
Enter
Open the focused link.
f
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.