Honda Ridgeline

Transmission parameters

The Honda Ridgeline has 4 transmission parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

Current gear var.2 RIDGELINE_CURRENT_GEAR_VAR_2

  • Request22 26 12
  • Service 22DID 2612
  • ModuleDA0E → 0E
  • Every1 s
  • Testing

Bits 352 to 359 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2006 to 2014, 2017 to 2021, 2024 to 2026. Not supported for 2022 to 2023.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Current gear var.2 RIDGELINE_CURRENT_GEAR_VAR_2

  • Request22 26 12
  • Service 22DID 2612
  • ModuleDA0E → 0E
  • Every1 s
  • Testing

Bits 352 to 359 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2006 to 2014, 2017 to 2021, 2024 to 2026. Not supported for 2022 to 2023.

Current gear var.3 RIDGELINE_CURRENT_GEAR_VAR_3

  • Request22 26 12
  • Service 22DID 2612
  • ModuleDA0E → 0E
  • Every1 s
  • Testing

Bits 368 to 375 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2006 to 2014, 2017 to 2021, 2024 to 2026. Not supported for 2022 to 2023.

Transmission fluid temperature RIDGELINE_ATF_T_DA1EConfirmed

  • Request22 30 83
  • Service 22DID 3083
  • ModuleDA1E → 1E
  • Every5 s
  • Testing for 2006 to 2014, 2017 to 2020

Bits 112 to 119 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 200 °C
Unit
°C

Confirmed for 2021 to 2026. In testing for 2006 to 2014, 2017 to 2018, 2020. Not supported for 2019.

Transmission gear RIDGELINE_GEARConfirmed

  • Request22 30 86
  • Service 22DID 3086
  • ModuleDA1E → 1E
  • Every250 ms
  • Testing for 2006 to 2014, 2017 to 2020

Bits 160 to 167 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
0PPark
1D1Drive 1
2D2Drive 2
3D3Drive 3
4D4Drive 4
5D5Drive 5
6D6Drive 6
7D7Drive 7
8D8Drive 8
9D9Drive 9
14NNeutral
15RReverse

Confirmed for 2021 to 2026. In testing for 2006 to 2014, 2017 to 2018, 2020. Not supported for 2019.

Keyboard shortcuts

jk/↓↑
Move down or up through a list or a grid.
hl/←→
Move across a row or between cards.
Enter
Open the focused link.
f
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.