ECU parameters
The Honda Ridgeline has 8 ECU parameters.
● Confirmed◆ In testing○ Supported× Not supported
Knock control RIDGELINE_KNOCK_CTRL_PCM
- Request
22 26 62 - Service 22
DID 2662 - Module
DA0E → 0E - Every
1 s - Testing
Bits 80 to 87 of the reply, 8 bits.
- Formula
(val × 2 ÷ 255)- Range
- 0 to 2
- Unit
- Number
In testing for 2006 to 2014, 2017 to 2021, 2023 to 2026. Not supported for 2022.
Misfire count, cylinder 1 RIDGELINE_MIS_1_PCM
- Request
22 26 63 - Service 22
DID 2663 - Module
DA0E → 0E - Every
1 s - Testing
Bits 272 to 287 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2006 to 2014, 2017 to 2021, 2023 to 2026. Not supported for 2022.
Misfire count, cylinder 2 RIDGELINE_MIS_2_PCM
- Request
22 26 63 - Service 22
DID 2663 - Module
DA0E → 0E - Every
1 s - Testing
Bits 288 to 303 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2006 to 2014, 2017 to 2021, 2023 to 2026. Not supported for 2022.
Misfire count, cylinder 3 RIDGELINE_MIS_3_PCM
- Request
22 26 63 - Service 22
DID 2663 - Module
DA0E → 0E - Every
1 s - Testing
Bits 304 to 319 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2006 to 2014, 2017 to 2021, 2023 to 2026. Not supported for 2022.
Misfire count, cylinder 4 RIDGELINE_MIS_4_PCM
- Request
22 26 63 - Service 22
DID 2663 - Module
DA0E → 0E - Every
1 s - Testing
Bits 320 to 335 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2006 to 2014, 2017 to 2021, 2023 to 2026. Not supported for 2022.
Misfire count, cylinder 5 RIDGELINE_MIS_5_PCM
- Request
22 26 63 - Service 22
DID 2663 - Module
DA0E → 0E - Every
1 s - Testing
Bits 336 to 351 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2006 to 2014, 2017 to 2021, 2023 to 2026. Not supported for 2022.
Misfire count, cylinder 6 RIDGELINE_MIS_6_PCM
- Request
22 26 63 - Service 22
DID 2663 - Module
DA0E → 0E - Every
1 s - Testing
Bits 352 to 367 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2006 to 2014, 2017 to 2021, 2023 to 2026. Not supported for 2022.
Variable valve control RIDGELINE_VTEC_CTRLConfirmed
- Request
22 26 12 - Service 22
DID 2612 - Module
DA10 → 10 - Every
250 ms - Testing for 2006 to 2014, 2017 to 2020
Bits 168 to 175 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
Confirmed for 2021 to 2026. In testing for 2006 to 2014, 2017 to 2018, 2020. Not supported for 2019.