Connectable parameters
The Honda Prologue has 28 Connectables, parameters that Pelican can monitor automatically.
● Confirmed◆ In testing○ Supported× Not supported
State of charge
State of charge HONDA_SOC
Pelican can show this parameter as the state of charge.
- Request
22 20 2A - Service 22
DID 202A - Module
DA01 → 01 - Every
1 s - Testing
Bits 400 to 407 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2026. Not supported for 2024 to 2025.
Fuel tank level
Fuel level HONDA_FLV
Pelican can show this parameter as the fuel tank level.
- Request
22 70 29 - Service 22
DID 7029 - Module
DA60 → 60 - Every
30 s - Testing
Bits 96 to 111 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655 L
- Unit
- L
In testing for 2026. Not supported for 2024 to 2025.
Speed
Vehicle speed VSSSAE J1979Confirmed
Pelican can show this parameter as the speed.
- Request
01 0D - Service 01
PID 0D - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 km/h
- Unit
- km/h
Confirmed for 2024 to 2025.
Odometer
Odometer HONDA_ODO_PCM
Pelican can show this parameter as the odometer.
- Request
22 26 60 - Service 22
DID 2660 - Module
DA0E → 0E - Every
30 s - Testing
Bits 344 to 367 of the reply, 24 bits.
- Formula
val- Range
- 0 to 16777215 km
- Unit
- km
In testing for 2024 to 2026.
Odometer HONDA_ODO
Pelican can show this parameter as the odometer.
- Request
22 26 60 - Service 22
DID 2660 - Module
DA10 → 10 - Every
5 s - Testing
Bits 344 to 367 of the reply, 24 bits.
- Formula
val- Range
- 0 to 16777215 km
- Unit
- km
In testing for 2026. Not supported for 2024 to 2025.
Odometer HONDA_ODO_V2
Pelican can show this parameter as the odometer.
- Request
22 26 60 - Service 22
DID 2660 - Module
DA1D → 1D - Every
30 s - Testing
Bits 344 to 367 of the reply, 24 bits.
- Formula
val- Range
- 0 to 16777215 km
- Unit
- km
In testing for 2026. Not supported for 2024 to 2025.
Odometer ODOSAE J1979Confirmed
Pelican can show this parameter as the odometer.
- Request
01 A6 - Service 01
PID A6 - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 31 of the reply, 32 bits.
- Formula
(val ÷ 10)- Range
- 0 to 429496729.5 km
- Unit
- km
Confirmed for 2024 to 2025.
Front left tire pressure
Front left tire pressure HONDA_TP_FL
Pelican can show this parameter as the front left tire pressure.
- Request
22 60 01 - Service 22
DID 6001 - Module
DA26 → 26 - Every
15 s - Testing
Bits 80 to 95 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 kPa
- Unit
- kPa
In testing for 2026. Not supported for 2024 to 2025.
Front right tire pressure
Front right tire pressure HONDA_TP_FR
Pelican can show this parameter as the front right tire pressure.
- Request
22 60 01 - Service 22
DID 6001 - Module
DA26 → 26 - Every
15 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 kPa
- Unit
- kPa
In testing for 2026. Not supported for 2024 to 2025.
Rear left tire pressure
Rear left tire pressure HONDA_TP_RL
Pelican can show this parameter as the rear left tire pressure.
- Request
22 60 01 - Service 22
DID 6001 - Module
DA26 → 26 - Every
15 s - Testing
Bits 112 to 127 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 kPa
- Unit
- kPa
In testing for 2026. Not supported for 2024 to 2025.
Rear right tire pressure
Rear right tire pressure HONDA_TP_RR
Pelican can show this parameter as the rear right tire pressure.
- Request
22 60 01 - Service 22
DID 6001 - Module
DA26 → 26 - Every
15 s - Testing
Bits 96 to 111 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 kPa
- Unit
- kPa
In testing for 2026. Not supported for 2024 to 2025.
CheckEngineLightOn
Malfunction indicator lamp MILSAE J1979Confirmed
The MIL status is OFF during key-on, engine-off bulb check unless MIL has also been commanded ON for a detected malfunction. The status reflects whether there are confirmed DTC(s) stored that are illuminating the MIL. It should not reflect the status of the MIL, which could be on for a function check, flashing I/M readiness or flashing for misfire.
Pelican can show this parameter as the checkEngineLightOn.
- Request
01 01 - Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 0 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
Confirmed for 2024 to 2025.
Distance since trouble codes were cleared
Distance traveled since diagnostic trouble codes cleared CLR_DISTSAE J1979Confirmed
Distance accumulated since DTCs were cleared (via an external test equipment or possibly, a battery disconnect). This parameter is not associated with any particular DTC. It is simply an indication for inspection/maintenance, of the last time an external test equipment was used to clear DTCs. If greater than 65,535 km have occurred, will remain at 65,535 km and not wrap to zero.
Pelican can show this parameter as the distance since trouble codes were cleared.
- Request
01 31 - Service 01
PID 31 - Module
7E0 → 7E8 - Every
15 s
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 km
- Unit
- km
Confirmed for 2024 to 2025.
Engine coolant temperature
Engine coolant temperature sensor 1 HONDA_ECT_1
Pelican can show this parameter as the engine coolant temperature.
- Request
22 20 2C - Service 22
DID 202C - Module
DA01 → 01 - Every
5 s - Testing
Bits 1,608 to 1,623 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2026. Not supported for 2024 to 2025.
Engine coolant temperature sensor 2 HONDA_ECT_2
Pelican can show this parameter as the engine coolant temperature.
- Request
22 20 2C - Service 22
DID 202C - Module
DA01 → 01 - Every
5 s - Testing
Bits 1,624 to 1,639 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2026. Not supported for 2024 to 2025.
Engine coolant temperature sensor 3 HONDA_ECT_3
Pelican can show this parameter as the engine coolant temperature.
- Request
22 20 2C - Service 22
DID 202C - Module
DA01 → 01 - Every
5 s - Testing
Bits 1,640 to 1,655 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2026. Not supported for 2024 to 2025.
Engine coolant temperature sensor 4 HONDA_ECT_4
Pelican can show this parameter as the engine coolant temperature.
- Request
22 20 2C - Service 22
DID 202C - Module
DA01 → 01 - Every
5 s - Testing
Bits 1,656 to 1,671 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2026. Not supported for 2024 to 2025.
Front left tire temperature
Front left tire temperature HONDA_TT_FL
Pelican can show this parameter as the front left tire temperature.
- Request
22 60 01 - Service 22
DID 6001 - Module
DA26 → 26 - Every
15 s - Testing
Bits 200 to 207 of the reply, 8 bits. The value is signed.
- Formula
val- Range
- -128 to 127 °C
- Unit
- °C
In testing for 2026. Not supported for 2024 to 2025.
Front right tire temperature
Front right tire temperature HONDA_TT_FR
Pelican can show this parameter as the front right tire temperature.
- Request
22 60 01 - Service 22
DID 6001 - Module
DA26 → 26 - Every
15 s - Testing
Bits 192 to 199 of the reply, 8 bits. The value is signed.
- Formula
val- Range
- -128 to 127 °C
- Unit
- °C
In testing for 2026. Not supported for 2024 to 2025.
Rear left tire temperature
Rear left tire temperature HONDA_TT_RL
Pelican can show this parameter as the rear left tire temperature.
- Request
22 60 01 - Service 22
DID 6001 - Module
DA26 → 26 - Every
15 s - Testing
Bits 216 to 223 of the reply, 8 bits. The value is signed.
- Formula
val- Range
- -128 to 127 °C
- Unit
- °C
In testing for 2026. Not supported for 2024 to 2025.
Rear right tire temperature
Rear right tire temperature HONDA_TT_RR
Pelican can show this parameter as the rear right tire temperature.
- Request
22 60 01 - Service 22
DID 6001 - Module
DA26 → 26 - Every
15 s - Testing
Bits 208 to 215 of the reply, 8 bits. The value is signed.
- Formula
val- Range
- -128 to 127 °C
- Unit
- °C
In testing for 2026. Not supported for 2024 to 2025.
Starter battery voltage
Control module voltage VPWRSAE J1979Confirmed
Power input to the OBD control module. VPWR is normally battery voltage, less any voltage drop in the circuit between the battery and the control module.
Pelican can show this parameter as the starter battery voltage.
- Request
01 42 - Service 01
PID 42 - Module
7E0 → 7E8 - Every
10 s
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65535 V
- Unit
- V
Confirmed for 2024 to 2025.
High voltage battery voltage, line B HONDA_HVB_V_B
Pelican can show this parameter as the starter battery voltage.
- Request
22 20 2A - Service 22
DID 202A - Module
DA16 → 16 - Every
1 s - Testing
Bits 488 to 503 of the reply, 16 bits.
- Formula
(val ÷ 20)- Range
- 0 to 400 V
- Unit
- V
In testing for 2026. Not supported for 2024 to 2025.
StoredDTCCount
Number of DTCs stored in this ECU DTC_CNTSAE J1979Confirmed
Number of confirmed emission-related DTCs stored in the ECU available for display using Service $03.
Pelican can show this parameter as the storedDTCCount.
- Request
01 01 - Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bits 1 to 7 of the reply, 7 bits.
- Formula
val- Range
- 0 to 127
- Unit
- Number
Confirmed for 2024 to 2025.
Traction battery current
High voltage battery total current HONDA_HVB_C_TOTAL
Pelican can show this parameter as the traction battery current.
- Request
22 20 2A - Service 22
DID 202A - Module
DA01 → 01 - Every
1 s - Testing
Bits 456 to 471 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 50)- Range
- -100 to 200 A
- Unit
- A
In testing for 2026. Not supported for 2024 to 2025.
Traction battery voltage
High voltage battery voltage HONDA_HVB_V
Pelican can show this parameter as the traction battery voltage.
- Request
22 20 2A - Service 22
DID 202A - Module
DA01 → 01 - Every
1 s - Testing
Bits 488 to 503 of the reply, 16 bits.
- Formula
(val ÷ 20)- Range
- 0 to 400 V
- Unit
- V
In testing for 2026. Not supported for 2024 to 2025.
Transmission fluid temperature
Transmission fluid temperature HONDA_ATF_T_V2
Pelican can show this parameter as the transmission fluid temperature.
- Request
22 30 83 - Service 22
DID 3083 - Module
DA1E → 1E - Every
5 s - Testing
Bits 112 to 119 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 200 °C
- Unit
- °C
In testing for 2026. Not supported for 2024 to 2025.
Transmission fluid temperature, variant 4 HONDA_ATF_T_VAR_4
Pelican can show this parameter as the transmission fluid temperature.
- Request
22 22 01 - Service 22
DID 2201 - Module
DA1E → 1E - Every
5 s - Testing
Bits 208 to 215 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2024 to 2026.