Trip parameters
The Honda Prologue has 5 trip parameters.
● Confirmed◆ In testing○ Supported× Not supported
Odometer HONDA_ODO
Pelican can show this parameter as the odometer.
- Request
22 26 60 - Service 22
DID 2660 - Module
DA10 → 10 - Every
5 s - Testing
Bits 344 to 367 of the reply, 24 bits.
- Formula
val- Range
- 0 to 16777215 km
- Unit
- km
In testing for 2026. Not supported for 2024 to 2025.
Odometer HONDA_ODO_PCM
Pelican can show this parameter as the odometer.
- Request
22 26 60 - Service 22
DID 2660 - Module
DA0E → 0E - Every
30 s - Testing
Bits 344 to 367 of the reply, 24 bits.
- Formula
val- Range
- 0 to 16777215 km
- Unit
- km
In testing for 2024 to 2026.
Odometer HONDA_ODO_V2
Pelican can show this parameter as the odometer.
- Request
22 26 60 - Service 22
DID 2660 - Module
DA1D → 1D - Every
30 s - Testing
Bits 344 to 367 of the reply, 24 bits.
- Formula
val- Range
- 0 to 16777215 km
- Unit
- km
In testing for 2026. Not supported for 2024 to 2025.
Odometer ODOSAE J1979Confirmed
Pelican can show this parameter as the odometer.
- Request
01 A6 - Service 01
PID A6 - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 31 of the reply, 32 bits.
- Formula
(val ÷ 10)- Range
- 0 to 429496729.5 km
- Unit
- km
Confirmed for 2024 to 2025.
Odometer, variation 3 HONDA_ODO_V3
- Request
22 70 22 - Service 22
DID 7022 - Module
DA60 → 60 - Every
30 s - Testing
Bits 48 to 71 of the reply, 24 bits.
- Formula
val- Range
- 0 to 200000 mi
- Unit
- mi
In testing for 2026. Not supported for 2024 to 2025.