Honda Prologue

Battery parameters

The Honda Prologue has 202 battery parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

Battery coolant temperature HONDA_BATTERY_COOLANT_TEMPERATURE

  • Request22 20 01
  • Service 22DID 2001
  • ModuleDBEF
  • Every5 s
  • Testing

Bits 88 to 95 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2024 to 2026.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Battery coolant temperature HONDA_BATTERY_COOLANT_TEMPERATURE

  • Request22 20 01
  • Service 22DID 2001
  • ModuleDBEF
  • Every5 s
  • Testing

Bits 88 to 95 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2024 to 2026.

Battery module power HONDA_BATTERY_MODULE_POWER

  • Request22 20 01
  • Service 22DID 2001
  • ModuleDBEF
  • Every5 s
  • Testing

Bits 168 to 183 of the reply, 16 bits. The value is signed.

Formula
(val × 0.016)
Range
-524.288 to 524.272 kW
Unit
kW

In testing for 2024 to 2026.

Cell voltage limit during charge HONDA_CEL_V_LIM

  • Request22 20 29
  • Service 22DID 2029
  • ModuleDA15 → 15
  • Every1 s
  • Testing

Bits 392 to 407 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2026. Not supported for 2024 to 2025.

Charging voltage target HONDA_CHG_V_TGT

  • Request22 20 29
  • Service 22DID 2029
  • ModuleDA15 → 15
  • Every1 s
  • Testing

Bits 272 to 287 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2026. Not supported for 2024 to 2025.

Control module voltage VPWRSAE J1979Confirmed

Power input to the OBD control module. VPWR is normally battery voltage, less any voltage drop in the circuit between the battery and the control module.

Pelican can show this parameter as the starter battery voltage.

  • Request01 42
  • Service 01PID 42
  • Module7E0 → 7E8
  • Every10 s

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65535 V
Unit
V

Confirmed for 2024 to 2025.

Distance traveled since last charge HONDA_BAT_DIST

  • Request22 22 40
  • Service 22DID 2240
  • ModuleDA0E → 0E
  • Every30 s
  • Testing

Bits 80 to 111 of the reply, 32 bits.

Formula
val
Range
0 to 250000 km
Unit
km

In testing for 2026. Not supported for 2024 to 2025.

High voltage battery cells, max state of charge HONDA_CELL_MAX_SOC

  • Request22 20 2A
  • Service 22DID 202A
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 584 to 599 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 100 %
Unit
%

In testing for 2026. Not supported for 2024 to 2025.

High voltage battery cells, max state of charge HONDA_CELL_MIN_SOC

  • Request22 20 2A
  • Service 22DID 202A
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 600 to 615 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 100 %
Unit
%

In testing for 2026. Not supported for 2024 to 2025.

High voltage battery module 1A temperature HONDA_HVB_MOD_1A_T

  • Request22 20 2C
  • Service 22DID 202C
  • ModuleDA01 → 01
  • Every5 s
  • Testing

Bits 472 to 487 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-40 to 215 °C
Unit
°C

In testing for 2026. Not supported for 2024 to 2025.

High voltage battery module 1B temperature HONDA_HVB_MOD_1B_T

  • Request22 20 2C
  • Service 22DID 202C
  • ModuleDA16 → 16
  • Every5 s
  • Testing

Bits 472 to 487 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-40 to 215 °C
Unit
°C

In testing for 2026. Not supported for 2024 to 2025.

High voltage battery module 2A temperature HONDA_HVB_MOD_2A_T

  • Request22 20 2C
  • Service 22DID 202C
  • ModuleDA16 → 16
  • Every5 s
  • Testing

Bits 488 to 503 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-40 to 215 °C
Unit
°C

In testing for 2026. Not supported for 2024 to 2025.

High voltage battery module 3A temperature HONDA_HVB_MOD_3A_T

  • Request22 20 2C
  • Service 22DID 202C
  • ModuleDA01 → 01
  • Every5 s
  • Testing

Bits 504 to 519 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-40 to 215 °C
Unit
°C

In testing for 2026. Not supported for 2024 to 2025.

High voltage battery module 3B temperature HONDA_HVB_MOD_3B_T

  • Request22 20 2C
  • Service 22DID 202C
  • ModuleDA16 → 16
  • Every5 s
  • Testing

Bits 504 to 519 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-40 to 215 °C
Unit
°C

In testing for 2026. Not supported for 2024 to 2025.

High voltage battery module 4B temperature HONDA_HVB_MOD_4B_T

  • Request22 20 2C
  • Service 22DID 202C
  • ModuleDA16 → 16
  • Every5 s
  • Testing

Bits 520 to 535 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-40 to 215 °C
Unit
°C

In testing for 2026. Not supported for 2024 to 2025.

High voltage battery total capacity HONDA_HVB_CAP

  • Request22 20 2A
  • Service 22DID 202A
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 1,336 to 1,351 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 655.35 Ah
Unit
Ah

In testing for 2026. Not supported for 2024 to 2025.

High voltage battery total current HONDA_HVB_C_TOTAL

Pelican can show this parameter as the traction battery current.

  • Request22 20 2A
  • Service 22DID 202A
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 456 to 471 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 50)
Range
-100 to 200 A
Unit
A

In testing for 2026. Not supported for 2024 to 2025.

High voltage battery voltage HONDA_HVB_V

Pelican can show this parameter as the traction battery voltage.

  • Request22 20 2A
  • Service 22DID 202A
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 488 to 503 of the reply, 16 bits.

Formula
(val ÷ 20)
Range
0 to 400 V
Unit
V

In testing for 2026. Not supported for 2024 to 2025.

High voltage battery voltage, line B HONDA_HVB_V_B

Pelican can show this parameter as the starter battery voltage.

  • Request22 20 2A
  • Service 22DID 202A
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 488 to 503 of the reply, 16 bits.

Formula
(val ÷ 20)
Range
0 to 400 V
Unit
V

In testing for 2026. Not supported for 2024 to 2025.

HV battery cell max state of charge HONDA_HV_BATTERY_CELL_MAX_STATE_OF_CHARGE

  • Request22 20 12
  • Service 22DID 2012
  • ModuleDBEF
  • Every1 s
  • Testing

Bits 208 to 223 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 100)
Range
-327.68 to 100 %
Unit
%

In testing for 2024 to 2026.

HV battery current HONDA_HV_BATTERY_CURRENT

  • Request22 20 10
  • Service 22DID 2010
  • ModuleDBEF
  • Every5 s
  • Testing

Bits 32 to 47 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 100)
Range
-327.68 to 327.67 A
Unit
A

In testing for 2024 to 2026.

HV battery fan 3 speed HONDA_HV_BATTERY_FAN_3_SPEED

  • Request22 20 01
  • Service 22DID 2001
  • ModuleDBEF
  • Every5 s
  • Testing

Bits 288 to 295 of the reply, 8 bits.

Formula
(val × 100)
Range
0 to 25500 rpm
Unit
rpm

In testing for 2024 to 2026.

HV battery max cell voltage HONDA_HV_BATTERY_MAX_CELL_VOLTAGE

  • Request22 22 22
  • Service 22DID 2222
  • ModuleDBEF
  • Every1 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 13107 mV
Unit
mV

In testing for 2024 to 2026.

HV battery usable capacity HONDA_HV_BATTERY_USABLE_CAPACITY

  • Request22 20 12
  • Service 22DID 2012
  • ModuleDBEF
  • Every1 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2024 to 2026.

Motor assist battery temperature HONDA_IMA_BAT_T

  • Request22 26 14
  • Service 22DID 2614
  • ModuleDA11 → 11
  • Every5 s
  • Testing

Bits 176 to 183 of the reply, 8 bits.

Formula
(val × 9 ÷ 5 − 40)
Range
-40 to 419 °C
Unit
°C

In testing for 2024 to 2026.

Motor assist battery temperature HONDA_IMA_BAT_T_DA10

  • Request22 26 14
  • Service 22DID 2614
  • ModuleDA10 → 10
  • Every5 s
  • Testing

Bits 176 to 183 of the reply, 8 bits.

Formula
(val × 9 ÷ 5 − 40)
Range
-40 to 419 °C
Unit
°C

In testing for 2024 to 2026.

Normal charger input voltage HONDA_CHG_V_IN

  • Request22 20 21
  • Service 22DID 2021
  • ModuleDA15 → 15
  • Every5 s
  • Testing

Bits 240 to 255 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 500 V
Unit
V

In testing for 2026. Not supported for 2024 to 2025.

Normal charger output voltage HONDA_CHG_V_OUT

  • Request22 20 21
  • Service 22DID 2021
  • ModuleDA15 → 15
  • Every5 s
  • Testing

Bits 272 to 287 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 500 V
Unit
V

In testing for 2026. Not supported for 2024 to 2025.

State of charge HONDA_SOC

Pelican can show this parameter as the state of charge.

  • Request22 20 2A
  • Service 22DID 202A
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 400 to 407 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2026. Not supported for 2024 to 2025.

State of charge HONDA_STATE_OF_CHARGE

  • Request22 20 12
  • Service 22DID 2012
  • ModuleDBEF
  • Every1 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2024 to 2026.

State of charge, raw count HONDA_ST_CHG_RAW_CNT

  • Request22 26 14
  • Service 22DID 2614
  • ModuleDA11 → 11
  • Every5 s
  • Testing

Bits 144 to 159 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2024 to 2026.

State of charge, raw count HONDA_ST_CHG_RAW_CNT_DA10

  • Request22 26 14
  • Service 22DID 2614
  • ModuleDA10 → 10
  • Every5 s
  • Testing

Bits 144 to 159 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2024 to 2026.

Battery › Cells

Battery capacity, line B HONDA_HVB_CAP_B

  • Request22 20 2A
  • Service 22DID 202A
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 1,336 to 1,351 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 655.35 Ah
Unit
Ah

In testing for 2026. Not supported for 2024 to 2025.

Cell voltage, 1 HONDA_CEL_V_B1

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 216 to 231 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2026. Not supported for 2024 to 2025.

Cell voltage, 2 HONDA_CEL_V_B2

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 232 to 247 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2026. Not supported for 2024 to 2025.

Cell voltage, 3 HONDA_CEL_V_B3

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 248 to 263 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2026. Not supported for 2024 to 2025.

Cell voltage, 4 HONDA_CEL_V_B4

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 264 to 279 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2026. Not supported for 2024 to 2025.

Cell voltage, 5 HONDA_CEL_V_B5

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 280 to 295 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2026. Not supported for 2024 to 2025.

Cell voltage, 6 HONDA_CEL_V_B6

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 296 to 311 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2026. Not supported for 2024 to 2025.

Cell voltage, 7 HONDA_CEL_V_B7

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 312 to 327 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2026. Not supported for 2024 to 2025.

Cell voltage, 8 HONDA_CEL_V_B8

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 328 to 343 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2026. Not supported for 2024 to 2025.

Cell voltage, 9 HONDA_CEL_V_B9

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 344 to 359 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2026. Not supported for 2024 to 2025.

Cell voltage, 10 HONDA_CEL_V_B10

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 360 to 375 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2026. Not supported for 2024 to 2025.

Cell voltage, 11 HONDA_CEL_V_B11

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 376 to 391 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2026. Not supported for 2024 to 2025.

Cell voltage, 12 HONDA_CEL_V_B12

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 392 to 407 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2026. Not supported for 2024 to 2025.

Cell voltage, 13 HONDA_CEL_V_B13

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 408 to 423 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2026. Not supported for 2024 to 2025.

Cell voltage, 14 HONDA_CEL_V_B14

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 424 to 439 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2026. Not supported for 2024 to 2025.

Cell voltage, 15 HONDA_CEL_V_B15

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 440 to 455 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2026. Not supported for 2024 to 2025.

Cell voltage, 16 HONDA_CEL_V_B16

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 456 to 471 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2026. Not supported for 2024 to 2025.

Cell voltage, 17 HONDA_CEL_V_B17

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 472 to 487 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2026. Not supported for 2024 to 2025.

Cell voltage, 18 HONDA_CEL_V_B18

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 488 to 503 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2026. Not supported for 2024 to 2025.

Cell voltage, 19 HONDA_CEL_V_B19

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 504 to 519 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2026. Not supported for 2024 to 2025.

Cell voltage, 20 HONDA_CEL_V_B20

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 520 to 535 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2026. Not supported for 2024 to 2025.

Cell voltage, 21 HONDA_CEL_V_B21

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 536 to 551 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2026. Not supported for 2024 to 2025.

Cell voltage, 22 HONDA_CEL_V_B22

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 552 to 567 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2026. Not supported for 2024 to 2025.

Cell voltage, 23 HONDA_CEL_V_B23

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 568 to 583 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2026. Not supported for 2024 to 2025.

Cell voltage, 24 HONDA_CEL_V_B24

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 584 to 599 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2026. Not supported for 2024 to 2025.

Cell voltage, 25 HONDA_CEL_V_B25

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 600 to 615 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2026. Not supported for 2024 to 2025.

Cell voltage, 26 HONDA_CEL_V_B26

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 616 to 631 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2026. Not supported for 2024 to 2025.

Cell voltage, 27 HONDA_CEL_V_B27

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 632 to 647 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2026. Not supported for 2024 to 2025.

Cell voltage, 28 HONDA_CEL_V_B28

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 648 to 663 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2026. Not supported for 2024 to 2025.

Cell voltage, 29 HONDA_CEL_V_B29

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 664 to 679 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2026. Not supported for 2024 to 2025.

Cell voltage, 30 HONDA_CEL_V_B30

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 680 to 695 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2026. Not supported for 2024 to 2025.

Cell voltage, 31 HONDA_CEL_V_B31

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 696 to 711 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2026. Not supported for 2024 to 2025.

Cell voltage, 32 HONDA_CEL_V_B32

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 712 to 727 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2026. Not supported for 2024 to 2025.

Cell voltage, 33 HONDA_CEL_V_B33

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 728 to 743 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2026. Not supported for 2024 to 2025.

Cell voltage, 34 HONDA_CEL_V_B34

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 744 to 759 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2026. Not supported for 2024 to 2025.

Cell voltage, 35 HONDA_CEL_V_B35

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 760 to 775 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2026. Not supported for 2024 to 2025.

Cell voltage, 36 HONDA_CEL_V_B36

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 776 to 791 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2026. Not supported for 2024 to 2025.

Cell voltage, 37 HONDA_CEL_V_B37

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 792 to 807 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2026. Not supported for 2024 to 2025.

Cell voltage, 38 HONDA_CEL_V_B38

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 808 to 823 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2026. Not supported for 2024 to 2025.

Cell voltage, 39 HONDA_CEL_V_B39

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 824 to 839 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2026. Not supported for 2024 to 2025.

Cell voltage, 40 HONDA_CEL_V_B40

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 840 to 855 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2026. Not supported for 2024 to 2025.

Cell voltage, 41 HONDA_CEL_V_B41

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 856 to 871 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2026. Not supported for 2024 to 2025.

Cell voltage, 42 HONDA_CEL_V_B42

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 872 to 887 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2026. Not supported for 2024 to 2025.

Cell voltage, 43 HONDA_CEL_V_B43

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 888 to 903 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2026. Not supported for 2024 to 2025.

Cell voltage, 44 HONDA_CEL_V_B44

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 904 to 919 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2026. Not supported for 2024 to 2025.

Cell voltage, 45 HONDA_CEL_V_B45

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 920 to 935 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2026. Not supported for 2024 to 2025.

Cell voltage, 46 HONDA_CEL_V_B46

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 936 to 951 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2026. Not supported for 2024 to 2025.

Cell voltage, 47 HONDA_CEL_V_B47

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 952 to 967 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2026. Not supported for 2024 to 2025.

Cell voltage, 48 HONDA_CEL_V_B48

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 968 to 983 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2026. Not supported for 2024 to 2025.

Cell voltage, 49 HONDA_CEL_V_B49

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 984 to 999 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2026. Not supported for 2024 to 2025.

Cell voltage, 50 HONDA_CEL_V_B50

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 1,000 to 1,015 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2026. Not supported for 2024 to 2025.

Cell voltage, 51 HONDA_CEL_V_B51

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 1,016 to 1,031 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2026. Not supported for 2024 to 2025.

Cell voltage, 52 HONDA_CEL_V_B52

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 1,032 to 1,047 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2026. Not supported for 2024 to 2025.

Cell voltage, 53 HONDA_CEL_V_B53

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 1,048 to 1,063 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2026. Not supported for 2024 to 2025.

Cell voltage, 54 HONDA_CEL_V_B54

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 1,064 to 1,079 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2026. Not supported for 2024 to 2025.

Cell voltage, 55 HONDA_CEL_V_B55

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 1,080 to 1,095 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2026. Not supported for 2024 to 2025.

Cell voltage, 56 HONDA_CEL_V_B56

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 1,096 to 1,111 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2026. Not supported for 2024 to 2025.

Cell voltage, 57 HONDA_CEL_V_B57

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 1,112 to 1,127 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2026. Not supported for 2024 to 2025.

Cell voltage, 58 HONDA_CEL_V_B58

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 1,128 to 1,143 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2026. Not supported for 2024 to 2025.

Cell voltage, 59 HONDA_CEL_V_B59

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 1,144 to 1,159 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2026. Not supported for 2024 to 2025.

Cell voltage, 60 HONDA_CEL_V_B60

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 1,160 to 1,175 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2026. Not supported for 2024 to 2025.

Cell voltage, 61 HONDA_CEL_V_B61

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 1,176 to 1,191 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2026. Not supported for 2024 to 2025.

Cell voltage, 62 HONDA_CEL_V_B62

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 1,192 to 1,207 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2026. Not supported for 2024 to 2025.

Cell voltage, 63 HONDA_CEL_V_B63

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 1,208 to 1,223 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2026. Not supported for 2024 to 2025.

Cell voltage, 64 HONDA_CEL_V_B64

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 1,224 to 1,239 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2026. Not supported for 2024 to 2025.

Cell voltage, 65 HONDA_CEL_V_B65

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 1,240 to 1,255 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2026. Not supported for 2024 to 2025.

Cell voltage, 66 HONDA_CEL_V_B66

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 1,256 to 1,271 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2026. Not supported for 2024 to 2025.

Cell voltage, 67 HONDA_CEL_V_B67

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 1,272 to 1,287 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2026. Not supported for 2024 to 2025.

Cell voltage, 68 HONDA_CEL_V_B68

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 1,288 to 1,303 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2026. Not supported for 2024 to 2025.

Cell voltage, 69 HONDA_CEL_V_B69

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 1,304 to 1,319 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2026. Not supported for 2024 to 2025.

Cell voltage, 70 HONDA_CEL_V_B70

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 1,320 to 1,335 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2026. Not supported for 2024 to 2025.

Cell voltage, 71 HONDA_CEL_V_B71

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 1,336 to 1,351 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2026. Not supported for 2024 to 2025.

Cell voltage, 72 HONDA_CEL_V_B72

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 1,352 to 1,367 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2026. Not supported for 2024 to 2025.

Cell voltage, 73 HONDA_CEL_V_B73

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 1,368 to 1,383 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2026. Not supported for 2024 to 2025.

Cell voltage, 74 HONDA_CEL_V_B74

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 1,384 to 1,399 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2026. Not supported for 2024 to 2025.

Cell voltage, 75 HONDA_CEL_V_B75

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 1,400 to 1,415 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2026. Not supported for 2024 to 2025.

Cell voltage, 76 HONDA_CEL_V_B76

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 1,416 to 1,431 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2026. Not supported for 2024 to 2025.

Cell voltage, 77 HONDA_CEL_V_B77

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 1,432 to 1,447 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2026. Not supported for 2024 to 2025.

Cell voltage, 78 HONDA_CEL_V_B78

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 1,448 to 1,463 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2026. Not supported for 2024 to 2025.

Cell voltage, 79 HONDA_CEL_V_B79

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 1,464 to 1,479 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2026. Not supported for 2024 to 2025.

Cell voltage, 80 HONDA_CEL_V_B80

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 1,480 to 1,495 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2026. Not supported for 2024 to 2025.

Cell voltage, 81 HONDA_CEL_V_B81

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 1,496 to 1,511 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2026. Not supported for 2024 to 2025.

Cell voltage, 82 HONDA_CEL_V_B82

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 1,512 to 1,527 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2026. Not supported for 2024 to 2025.

Cell voltage, 83 HONDA_CEL_V_B83

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 1,528 to 1,543 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2026. Not supported for 2024 to 2025.

Cell voltage, 84 HONDA_CEL_V_B84

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 1,544 to 1,559 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2026. Not supported for 2024 to 2025.

Individual cell max SOC, line B HONDA_CEL_MAX_SOC_B

  • Request22 20 2A
  • Service 22DID 202A
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 584 to 599 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 100 %
Unit
%

In testing for 2026. Not supported for 2024 to 2025.

Individual cell min SOC, line B HONDA_CEL_MIN_SOC_B

  • Request22 20 2A
  • Service 22DID 202A
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 600 to 615 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 100 %
Unit
%

In testing for 2026. Not supported for 2024 to 2025.

Individual cell voltage A1 HONDA_CEL_V_A1

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 216 to 231 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2026. Not supported for 2024 to 2025.

Individual cell voltage A2 HONDA_CEL_V_A2

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 232 to 247 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2026. Not supported for 2024 to 2025.

Individual cell voltage A3 HONDA_CEL_V_A3

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 248 to 263 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2026. Not supported for 2024 to 2025.

Individual cell voltage A4 HONDA_CEL_V_A4

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 264 to 279 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2026. Not supported for 2024 to 2025.

Individual cell voltage A5 HONDA_CEL_V_A5

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 280 to 295 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2026. Not supported for 2024 to 2025.

Individual cell voltage A6 HONDA_CEL_V_A6

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 296 to 311 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2026. Not supported for 2024 to 2025.

Individual cell voltage A7 HONDA_CEL_V_A7

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 312 to 327 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2026. Not supported for 2024 to 2025.

Individual cell voltage A8 HONDA_CEL_V_A8

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 328 to 343 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2026. Not supported for 2024 to 2025.

Individual cell voltage A9 HONDA_CEL_V_A9

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 344 to 359 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2026. Not supported for 2024 to 2025.

Individual cell voltage A10 HONDA_CEL_V_A10

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 360 to 375 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2026. Not supported for 2024 to 2025.

Individual cell voltage A11 HONDA_CEL_V_A11

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 376 to 391 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2026. Not supported for 2024 to 2025.

Individual cell voltage A12 HONDA_CEL_V_A12

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 392 to 407 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2026. Not supported for 2024 to 2025.

Individual cell voltage A13 HONDA_CEL_V_A13

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 408 to 423 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2026. Not supported for 2024 to 2025.

Individual cell voltage A14 HONDA_CEL_V_A14

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 424 to 439 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2026. Not supported for 2024 to 2025.

Individual cell voltage A15 HONDA_CEL_V_A15

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 440 to 455 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2026. Not supported for 2024 to 2025.

Individual cell voltage A16 HONDA_CEL_V_A16

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 456 to 471 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2026. Not supported for 2024 to 2025.

Individual cell voltage A17 HONDA_CEL_V_A17

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 472 to 487 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2026. Not supported for 2024 to 2025.

Individual cell voltage A18 HONDA_CEL_V_A18

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 488 to 503 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2026. Not supported for 2024 to 2025.

Individual cell voltage A19 HONDA_CEL_V_A19

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 504 to 519 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2026. Not supported for 2024 to 2025.

Individual cell voltage A20 HONDA_CEL_V_A20

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 520 to 535 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2026. Not supported for 2024 to 2025.

Individual cell voltage A21 HONDA_CEL_V_A21

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 536 to 551 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2026. Not supported for 2024 to 2025.

Individual cell voltage A22 HONDA_CEL_V_A22

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 552 to 567 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2026. Not supported for 2024 to 2025.

Individual cell voltage A23 HONDA_CEL_V_A23

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 568 to 583 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2026. Not supported for 2024 to 2025.

Individual cell voltage A24 HONDA_CEL_V_A24

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 584 to 599 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2026. Not supported for 2024 to 2025.

Individual cell voltage A25 HONDA_CEL_V_A25

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 600 to 615 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2026. Not supported for 2024 to 2025.

Individual cell voltage A26 HONDA_CEL_V_A26

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 616 to 631 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2026. Not supported for 2024 to 2025.

Individual cell voltage A27 HONDA_CEL_V_A27

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 632 to 647 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2026. Not supported for 2024 to 2025.

Individual cell voltage A28 HONDA_CEL_V_A28

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 648 to 663 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2026. Not supported for 2024 to 2025.

Individual cell voltage A29 HONDA_CEL_V_A29

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 664 to 679 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2026. Not supported for 2024 to 2025.

Individual cell voltage A30 HONDA_CEL_V_A30

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 680 to 695 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2026. Not supported for 2024 to 2025.

Individual cell voltage A31 HONDA_CEL_V_A31

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 696 to 711 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2026. Not supported for 2024 to 2025.

Individual cell voltage A32 HONDA_CEL_V_A32

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 712 to 727 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2026. Not supported for 2024 to 2025.

Individual cell voltage A33 HONDA_CEL_V_A33

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 728 to 743 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2026. Not supported for 2024 to 2025.

Individual cell voltage A34 HONDA_CEL_V_A34

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 744 to 759 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2026. Not supported for 2024 to 2025.

Individual cell voltage A35 HONDA_CEL_V_A35

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 760 to 775 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2026. Not supported for 2024 to 2025.

Individual cell voltage A36 HONDA_CEL_V_A36

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 776 to 791 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2026. Not supported for 2024 to 2025.

Individual cell voltage A37 HONDA_CEL_V_A37

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 792 to 807 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2026. Not supported for 2024 to 2025.

Individual cell voltage A38 HONDA_CEL_V_A38

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 808 to 823 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2026. Not supported for 2024 to 2025.

Individual cell voltage A39 HONDA_CEL_V_A39

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 824 to 839 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2026. Not supported for 2024 to 2025.

Individual cell voltage A40 HONDA_CEL_V_A40

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 840 to 855 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2026. Not supported for 2024 to 2025.

Individual cell voltage A41 HONDA_CEL_V_A41

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 856 to 871 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2026. Not supported for 2024 to 2025.

Individual cell voltage A42 HONDA_CEL_V_A42

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 872 to 887 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2026. Not supported for 2024 to 2025.

Individual cell voltage A43 HONDA_CEL_V_A43

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 888 to 903 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2026. Not supported for 2024 to 2025.

Individual cell voltage A44 HONDA_CEL_V_A44

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 904 to 919 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2026. Not supported for 2024 to 2025.

Individual cell voltage A45 HONDA_CEL_V_A45

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 920 to 935 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2026. Not supported for 2024 to 2025.

Individual cell voltage A46 HONDA_CEL_V_A46

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 936 to 951 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2026. Not supported for 2024 to 2025.

Individual cell voltage A47 HONDA_CEL_V_A47

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 952 to 967 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2026. Not supported for 2024 to 2025.

Individual cell voltage A48 HONDA_CEL_V_A48

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 968 to 983 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2026. Not supported for 2024 to 2025.

Individual cell voltage A49 HONDA_CEL_V_A49

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 984 to 999 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2026. Not supported for 2024 to 2025.

Individual cell voltage A50 HONDA_CEL_V_A50

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 1,000 to 1,015 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2026. Not supported for 2024 to 2025.

Individual cell voltage A51 HONDA_CEL_V_A51

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 1,016 to 1,031 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2026. Not supported for 2024 to 2025.

Individual cell voltage A52 HONDA_CEL_V_A52

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 1,032 to 1,047 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2026. Not supported for 2024 to 2025.

Individual cell voltage A53 HONDA_CEL_V_A53

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 1,048 to 1,063 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2026. Not supported for 2024 to 2025.

Individual cell voltage A54 HONDA_CEL_V_A54

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 1,064 to 1,079 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2026. Not supported for 2024 to 2025.

Individual cell voltage A55 HONDA_CEL_V_A55

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 1,080 to 1,095 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2026. Not supported for 2024 to 2025.

Individual cell voltage A56 HONDA_CEL_V_A56

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 1,096 to 1,111 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2026. Not supported for 2024 to 2025.

Individual cell voltage A57 HONDA_CEL_V_A57

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 1,112 to 1,127 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2026. Not supported for 2024 to 2025.

Individual cell voltage A58 HONDA_CEL_V_A58

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 1,128 to 1,143 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2026. Not supported for 2024 to 2025.

Individual cell voltage A59 HONDA_CEL_V_A59

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 1,144 to 1,159 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2026. Not supported for 2024 to 2025.

Individual cell voltage A60 HONDA_CEL_V_A60

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 1,160 to 1,175 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2026. Not supported for 2024 to 2025.

Individual cell voltage A61 HONDA_CEL_V_A61

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 1,176 to 1,191 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2026. Not supported for 2024 to 2025.

Individual cell voltage A62 HONDA_CEL_V_A62

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 1,192 to 1,207 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2026. Not supported for 2024 to 2025.

Individual cell voltage A63 HONDA_CEL_V_A63

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 1,208 to 1,223 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2026. Not supported for 2024 to 2025.

Individual cell voltage A64 HONDA_CEL_V_A64

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 1,224 to 1,239 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2026. Not supported for 2024 to 2025.

Individual cell voltage A65 HONDA_CEL_V_A65

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 1,240 to 1,255 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2026. Not supported for 2024 to 2025.

Individual cell voltage A66 HONDA_CEL_V_A66

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 1,256 to 1,271 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2026. Not supported for 2024 to 2025.

Individual cell voltage A67 HONDA_CEL_V_A67

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 1,272 to 1,287 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2026. Not supported for 2024 to 2025.

Individual cell voltage A68 HONDA_CEL_V_A68

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 1,288 to 1,303 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2026. Not supported for 2024 to 2025.

Individual cell voltage A69 HONDA_CEL_V_A69

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 1,304 to 1,319 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2026. Not supported for 2024 to 2025.

Individual cell voltage A70 HONDA_CEL_V_A70

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 1,320 to 1,335 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2026. Not supported for 2024 to 2025.

Individual cell voltage A71 HONDA_CEL_V_A71

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 1,336 to 1,351 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2026. Not supported for 2024 to 2025.

Individual cell voltage A72 HONDA_CEL_V_A72

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 1,352 to 1,367 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2026. Not supported for 2024 to 2025.

Individual cell voltage A73 HONDA_CEL_V_A73

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 1,368 to 1,383 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2026. Not supported for 2024 to 2025.

Individual cell voltage A74 HONDA_CEL_V_A74

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 1,384 to 1,399 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2026. Not supported for 2024 to 2025.

Individual cell voltage A75 HONDA_CEL_V_A75

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 1,400 to 1,415 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2026. Not supported for 2024 to 2025.

Individual cell voltage A76 HONDA_CEL_V_A76

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 1,416 to 1,431 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2026. Not supported for 2024 to 2025.

Individual cell voltage A77 HONDA_CEL_V_A77

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 1,432 to 1,447 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2026. Not supported for 2024 to 2025.

Individual cell voltage A78 HONDA_CEL_V_A78

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 1,448 to 1,463 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2026. Not supported for 2024 to 2025.

Individual cell voltage A79 HONDA_CEL_V_A79

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 1,464 to 1,479 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2026. Not supported for 2024 to 2025.

Individual cell voltage A80 HONDA_CEL_V_A80

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 1,480 to 1,495 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2026. Not supported for 2024 to 2025.

Individual cell voltage A81 HONDA_CEL_V_A81

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 1,496 to 1,511 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2026. Not supported for 2024 to 2025.

Individual cell voltage A82 HONDA_CEL_V_A82

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 1,512 to 1,527 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2026. Not supported for 2024 to 2025.

Individual cell voltage A83 HONDA_CEL_V_A83

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 1,528 to 1,543 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2026. Not supported for 2024 to 2025.

Individual cell voltage A84 HONDA_CEL_V_A84

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 1,544 to 1,559 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2026. Not supported for 2024 to 2025.

Keyboard shortcuts

jk/↓↑
Move down or up through a list or a grid.
hl/←→
Move across a row or between cards.
Enter
Open the focused link.
f
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?