Honda Pilot

Transmission parameters

The Honda Pilot has 5 transmission parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

Current gear PILOT_GEAR

  • Request22 22 21
  • Service 22DID 2221
  • ModuleDA1D → 1D
  • Every1 s
  • Testing

Bits 184 to 191 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2003 to 2016, 2018, 2020 to 2023, 2026. Not supported for 2017, 2019, 2024 to 2025.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Current gear PILOT_GEAR

  • Request22 22 21
  • Service 22DID 2221
  • ModuleDA1D → 1D
  • Every1 s
  • Testing

Bits 184 to 191 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2003 to 2016, 2018, 2020 to 2023, 2026. Not supported for 2017, 2019, 2024 to 2025.

Current gear var.2 PILOT_CURRENT_GEAR_VAR_2Confirmed

  • Request22 26 12
  • Service 22DID 2612
  • ModuleDA0E → 0E
  • Every1 s
  • Testing for 2003 to 2016, 2018, 2020 to 2026

Bits 352 to 359 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2017, 2019. In testing for 2003 to 2016, 2018, 2020 to 2023, 2026. Not supported for 2024 to 2025.

Current gear var.3 PILOT_CURRENT_GEAR_VAR_3Confirmed

  • Request22 26 12
  • Service 22DID 2612
  • ModuleDA0E → 0E
  • Every1 s
  • Testing for 2003 to 2016, 2018, 2020 to 2026

Bits 368 to 375 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2017, 2019. In testing for 2003 to 2016, 2018, 2020 to 2023, 2026. Not supported for 2024 to 2025.

Transmission fluid temperature PILOT_ATF_T_V2Confirmed

  • Request22 30 83
  • Service 22DID 3083
  • ModuleDA1E → 1E
  • Every5 s
  • Testing for 2003 to 2016, 2018 to 2019, 2021 to 2026

Bits 112 to 119 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 200 °C
Unit
°C

Confirmed for 2017, 2020. In testing for 2003 to 2006, 2008 to 2012, 2014 to 2016, 2018, 2021 to 2022, 2026. Not supported for 2007, 2013, 2019, 2023 to 2025.

Transmission gear PILOT_GEAR_V2Confirmed

  • Request22 30 86
  • Service 22DID 3086
  • ModuleDA1E → 1E
  • Every250 ms
  • Testing for 2003 to 2016, 2018 to 2019, 2021 to 2026

Bits 160 to 167 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
0PPark
1D1Drive 1
2D2Drive 2
3D3Drive 3
4D4Drive 4
5D5Drive 5
6D6Drive 6
7D7Drive 7
8D8Drive 8
9D9Drive 9
14NNeutral
15RReverse

Confirmed for 2017, 2020. In testing for 2003 to 2006, 2008 to 2012, 2014 to 2016, 2018, 2021 to 2022, 2026. Not supported for 2007, 2013, 2019, 2023 to 2025.

Keyboard shortcuts

jk/↓↑
Move down or up through a list or a grid.
hl/←→
Move across a row or between cards.
Enter
Open the focused link.
f
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.