Brake fluid pressure PILOT_BRK_FLD_P
- Request
22 42 01 - Service 22
DID 4201 - Module
DA2A → 2A - Every
1 s - Testing
Bits 168 to 183 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 5
- Unit
- Raw value
In testing for 2003 to 2006, 2008 to 2012, 2014 to 2016, 2018, 2021 to 2022, 2026. Not supported for 2007, 2013, 2017, 2019 to 2020, 2023 to 2025.
Brake pedal stroke PILOT_BRK_PED_STK
- Request
22 42 01 - Service 22
DID 4201 - Module
DA2A → 2A - Every
1 s - Testing
Bits 88 to 103 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 50 mm
- Unit
- mm
In testing for 2003 to 2006, 2008 to 2012, 2014 to 2016, 2018, 2021 to 2022, 2026. Not supported for 2007, 2013, 2017, 2019 to 2020, 2023 to 2025.
Brake pressure PILOT_BRK_PConfirmed
- Request
22 40 05 - Service 22
DID 4005 - Module
DA28 → 28 - Every
1 s - Testing for 2003 to 2016, 2018, 2021 to 2022, 2026
Bits 56 to 71 of the reply, 16 bits.
- Formula
(val − 25)- Range
- 0 to 120 bar
- Unit
- bar
Confirmed for 2017, 2019 to 2020, 2023 to 2025. In testing for 2003 to 2006, 2008 to 2012, 2014 to 2016, 2018, 2021 to 2022, 2026. Not supported for 2007, 2013.
Brake switch PILOT_BRK_SWConfirmed
- Request
22 40 04 - Service 22
DID 4004 - Module
DA28 → 28 - Every
1 s - Testing for 2003 to 2016, 2018, 2021 to 2022, 2026
Bit 127 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
Confirmed for 2017, 2019 to 2020, 2023 to 2025. In testing for 2003 to 2006, 2008 to 2012, 2014 to 2016, 2018, 2021 to 2022, 2026. Not supported for 2007, 2013.
Master cylinder stroke PILOT_MSTR_CYL_STK
- Request
22 42 01 - Service 22
DID 4201 - Module
DA2A → 2A - Every
1 s - Testing
Bits 232 to 247 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276.8 to 3276.7 mm
- Unit
- mm
In testing for 2003 to 2006, 2008 to 2012, 2014 to 2016, 2018, 2021 to 2022, 2026. Not supported for 2007, 2013, 2017, 2019 to 2020, 2023 to 2025.
Slave cylinder stroke PILOT_SLV_CYL_STK
- Request
22 42 01 - Service 22
DID 4201 - Module
DA2A → 2A - Every
1 s - Testing
Bits 248 to 263 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 mm
- Unit
- mm
In testing for 2003 to 2006, 2008 to 2012, 2014 to 2016, 2018, 2021 to 2022, 2026. Not supported for 2007, 2013, 2017, 2019 to 2020, 2023 to 2025.