Engine exhaust flow rate EXH_RATESAE J1979Confirmed
- Request
01 9E - Service 01
PID 9E - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 13107 kg/h
- Unit
- kg/h
Confirmed for 2024.
Engine fuel rate (alternate) FUEL_RATE_ALTSAE J1979Confirmed
- Request
01 9D - Service 01
PID 9D - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 50)- Range
- 0 to 1310.7 g/s
- Unit
- g/s
Confirmed for 2024.
Fuel level PILOT_FLVConfirmed
Pelican can show this parameter as the fuel tank level.
- Request
22 70 29 - Service 22
DID 7029 - Module
DA60 → 60 - Every
30 s - Testing for 2003 to 2016, 2018, 2021 to 2022, 2026
Bits 96 to 111 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655 L
- Unit
- L
Confirmed for 2017, 2019 to 2020, 2023 to 2025. In testing for 2003 to 2006, 2008 to 2012, 2014 to 2016, 2018, 2021 to 2022, 2026. Not supported for 2007, 2013.
Fuel system 1 status FUELSYS1SAE J1979Confirmed
- Request
01 03 - Service 01
PID 03 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
0 | OFF | Engine is off |
1 | OL | Open loop - has not yet satisfied conditions to go closed loop |
2 | CL | Closed loop - using oxygen sensor(s) as feedback for fuel control |
4 | OL-Drive | Open loop due to driving conditions (e.g. power enrichment, deceleration enleanment) |
8 | OL-Fault | Open loop - due to detected system fault |
16 | CL-Fault | Closed loop, but fault with at least one oxygen sensor - may be using single oxygen sensor for fuel control |
32 | OL B2 | Open loop - has not yet satisfied conditions to go closed loop (Bank 2) |
64 | OL-Drive B2 | Open loop due to driving conditions (Bank 2) (e.g. power enrichment, deceleration enleanment, cylinder deactivation) |
128 | OL-Fault B2 | Open loop - due to detected system fault (Bank 2) |
Confirmed for 2017, 2024. Supported for 2013, 2018 to 2020, 2023, 2025.
Fuel system 2 status FUELSYS2SAE J1979Confirmed
- Request
01 03 - Service 01
PID 03 - Module
7E0 → 7E8 - Every
250 ms
Bits 8 to 15 of the reply, 8 bits.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
0 | OFF | Engine is off |
1 | OL | Open loop - has not yet satisfied conditions to go closed loop |
2 | CL | Closed loop - using oxygen sensor(s) as feedback for fuel control |
4 | OL-Drive | Open loop due to driving conditions (e.g. power enrichment, deceleration enleanment) |
8 | OL-Fault | Open loop - due to detected system fault |
16 | CL-Fault | Closed loop, but fault with at least one oxygen sensor - may be using single oxygen sensor for fuel control |
32 | OL B2 | Open loop - has not yet satisfied conditions to go closed loop (Bank 2) |
64 | OL-Drive B2 | Open loop due to driving conditions (Bank 2) (e.g. power enrichment, deceleration enleanment, cylinder deactivation) |
128 | OL-Fault B2 | Open loop - due to detected system fault (Bank 2) |
Confirmed for 2017, 2024. Supported for 2013, 2018 to 2020, 2023, 2025.
Fuel system A use percentage bank 1 FUELSYSA_B1SAE J1979Confirmed
- Request
01 9F - Service 01
PID 9F - Module
7E0 → 7E8 - Every
250 ms
Bits 8 to 15 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2017, 2024.
Fuel system A use percentage bank 2 FUELSYSA_B2SAE J1979Confirmed
- Request
01 9F - Service 01
PID 9F - Module
7E0 → 7E8 - Every
250 ms
Bits 24 to 31 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2017, 2024.
Fuel system A use percentage bank 3 FUELSYSA_B3SAE J1979Confirmed
- Request
01 9F - Service 01
PID 9F - Module
7E0 → 7E8 - Every
250 ms
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2017, 2024.
Fuel system A use percentage bank 4 FUELSYSA_B4SAE J1979Confirmed
- Request
01 9F - Service 01
PID 9F - Module
7E0 → 7E8 - Every
250 ms
Bits 56 to 63 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2017, 2024.
Fuel system B use percentage bank 1 FUELSYSB_B1SAE J1979Confirmed
- Request
01 9F - Service 01
PID 9F - Module
7E0 → 7E8 - Every
250 ms
Bits 16 to 23 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2017, 2024.
Fuel system B use percentage bank 2 FUELSYSB_B2SAE J1979Confirmed
- Request
01 9F - Service 01
PID 9F - Module
7E0 → 7E8 - Every
250 ms
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2017, 2024.
Fuel system B use percentage bank 3 FUELSYSB_B3SAE J1979Confirmed
- Request
01 9F - Service 01
PID 9F - Module
7E0 → 7E8 - Every
250 ms
Bits 48 to 55 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2017, 2024.
Fuel system B use percentage bank 4 FUELSYSB_B4SAE J1979Confirmed
- Request
01 9F - Service 01
PID 9F - Module
7E0 → 7E8 - Every
250 ms
Bits 64 to 71 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2017, 2024.
Fuel tank level FLISAE J1979Confirmed
Pelican can show this parameter as the fuel tank level.
- Request
01 2F - Service 01
PID 2F - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2013, 2017, 2019 to 2020, 2024 to 2025. Supported for 2018, 2023.
Fuel/air commanded equivalence ratio PILOT_FUEL_AIR_RATIOConfirmed
- Request
22 26 11 - Service 22
DID 2611 - Module
DA10 → 10 - Every
5 s - Testing for 2003 to 2016, 2018 to 2019, 2021 to 2022, 2026
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
Confirmed for 2017, 2020, 2023 to 2025. In testing for 2003 to 2006, 2008 to 2012, 2014 to 2016, 2018, 2021 to 2022, 2026. Not supported for 2007, 2013, 2019.
Fuel/air commanded equivalence ratio PILOT_FUEL_AIR_RATIO_PCMConfirmed
- Request
22 26 11 - Service 22
DID 2611 - Module
DA0E → 0E - Every
5 s - Testing for 2003 to 2016, 2018, 2020 to 2026
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
Confirmed for 2017, 2019. In testing for 2003 to 2016, 2018, 2020 to 2023, 2026. Not supported for 2024 to 2025.
Vehicle fuel rate VFUEL_RATESAE J1979Confirmed
- Request
01 9D - Service 01
PID 9D - Module
7E0 → 7E8 - Every
250 ms
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val ÷ 50)- Range
- 0 to 1310.7 g/s
- Unit
- g/s
Confirmed for 2024.
Fuel › Internal
Fuel system A use percentage bank 1 supported FUELSYSA_B1_SUPSAE J1979Confirmed
- Request
01 9F - Service 01
PID 9F - Module
7E0 → 7E8 - Every
250 ms
Bit 7 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2017, 2024.
Fuel system A use percentage bank 2 supported FUELSYSA_B2_SUPSAE J1979Confirmed
- Request
01 9F - Service 01
PID 9F - Module
7E0 → 7E8 - Every
250 ms
Bit 5 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2017, 2024.
Fuel system A use percentage bank 3 supported FUELSYSA_B3_SUPSAE J1979Confirmed
- Request
01 9F - Service 01
PID 9F - Module
7E0 → 7E8 - Every
250 ms
Bit 3 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2017, 2024.
Fuel system A use percentage bank 4 supported FUELSYSA_B4_SUPSAE J1979Confirmed
- Request
01 9F - Service 01
PID 9F - Module
7E0 → 7E8 - Every
250 ms
Bit 1 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2017, 2024.
Fuel system B use percentage bank 1 supported FUELSYSB_B1_SUPSAE J1979Confirmed
- Request
01 9F - Service 01
PID 9F - Module
7E0 → 7E8 - Every
250 ms
Bit 6 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2017, 2024.
Fuel system B use percentage bank 2 supported FUELSYSB_B2_SUPSAE J1979Confirmed
- Request
01 9F - Service 01
PID 9F - Module
7E0 → 7E8 - Every
250 ms
Bit 4 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2017, 2024.
Fuel system B use percentage bank 3 supported FUELSYSB_B3_SUPSAE J1979Confirmed
- Request
01 9F - Service 01
PID 9F - Module
7E0 → 7E8 - Every
250 ms
Bit 2 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2017, 2024.
Fuel system B use percentage bank 4 supported FUELSYSB_B4_SUPSAE J1979Confirmed
- Request
01 9F - Service 01
PID 9F - Module
7E0 → 7E8 - Every
250 ms
Bit 0 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2017, 2024.