ECU parameters
The Honda Pilot has 16 ECU parameters.
● Confirmed◆ In testing○ Supported× Not supported
Knock control PILOT_KNOCK_CONTROLConfirmed
- Request
22 26 62 - Service 22
DID 2662 - Module
DA10 → 10 - Every
250 ms - Testing for 2003 to 2016, 2018 to 2019, 2021 to 2022, 2026
Bits 80 to 87 of the reply, 8 bits.
- Formula
(val × 2 ÷ 255)- Range
- 0 to 2
- Unit
- Number
Confirmed for 2017, 2020, 2023 to 2025. In testing for 2003 to 2006, 2008 to 2012, 2014 to 2016, 2018, 2021 to 2022, 2026. Not supported for 2007, 2013, 2019.
Knock control PILOT_KNOCK_CONTROL_PCMConfirmed
- Request
22 26 62 - Service 22
DID 2662 - Module
DA0E → 0E - Every
250 ms - Testing for 2003 to 2016, 2018, 2020 to 2026
Bits 80 to 87 of the reply, 8 bits.
- Formula
(val × 2 ÷ 255)- Range
- 0 to 2
- Unit
- Number
Confirmed for 2017, 2019. In testing for 2003 to 2016, 2018, 2020 to 2023, 2026. Not supported for 2024 to 2025.
Misfire count, cylinder 1 PILOT_MIS_1Confirmed
- Request
22 26 63 - Service 22
DID 2663 - Module
DA10 → 10 - Every
1 s - Testing for 2003 to 2016, 2018 to 2019, 2021 to 2022, 2026
Bits 272 to 287 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
Confirmed for 2017, 2020, 2023 to 2025. In testing for 2003 to 2006, 2008 to 2012, 2014 to 2016, 2018, 2021 to 2022, 2026. Not supported for 2007, 2013, 2019.
Misfire count, cylinder 1 PILOT_MIS_1_PCMConfirmed
- Request
22 26 63 - Service 22
DID 2663 - Module
DA0E → 0E - Every
1 s - Testing for 2003 to 2018, 2020 to 2026
Bits 272 to 287 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
Confirmed for 2019. In testing for 2003 to 2016, 2018, 2020 to 2023, 2026. Not supported for 2017, 2024 to 2025.
Misfire count, cylinder 2 PILOT_MIS_2Confirmed
- Request
22 26 63 - Service 22
DID 2663 - Module
DA10 → 10 - Every
1 s - Testing for 2003 to 2016, 2018 to 2019, 2021 to 2022, 2026
Bits 288 to 303 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
Confirmed for 2017, 2020, 2023 to 2025. In testing for 2003 to 2006, 2008 to 2012, 2014 to 2016, 2018, 2021 to 2022, 2026. Not supported for 2007, 2013, 2019.
Misfire count, cylinder 2 PILOT_MIS_2_PCMConfirmed
- Request
22 26 63 - Service 22
DID 2663 - Module
DA0E → 0E - Every
1 s - Testing for 2003 to 2018, 2020 to 2026
Bits 288 to 303 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
Confirmed for 2019. In testing for 2003 to 2016, 2018, 2020 to 2023, 2026. Not supported for 2017, 2024 to 2025.
Misfire count, cylinder 3 PILOT_MIS_3Confirmed
- Request
22 26 63 - Service 22
DID 2663 - Module
DA10 → 10 - Every
1 s - Testing for 2003 to 2016, 2018 to 2019, 2021 to 2022, 2026
Bits 304 to 319 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
Confirmed for 2017, 2020, 2023 to 2025. In testing for 2003 to 2006, 2008 to 2012, 2014 to 2016, 2018, 2021 to 2022, 2026. Not supported for 2007, 2013, 2019.
Misfire count, cylinder 3 PILOT_MIS_3_PCMConfirmed
- Request
22 26 63 - Service 22
DID 2663 - Module
DA0E → 0E - Every
1 s - Testing for 2003 to 2018, 2020 to 2026
Bits 304 to 319 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
Confirmed for 2019. In testing for 2003 to 2016, 2018, 2020 to 2023, 2026. Not supported for 2017, 2024 to 2025.
Misfire count, cylinder 4 PILOT_MIS_4Confirmed
- Request
22 26 63 - Service 22
DID 2663 - Module
DA10 → 10 - Every
1 s - Testing for 2003 to 2016, 2018 to 2019, 2021 to 2022, 2026
Bits 320 to 335 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
Confirmed for 2017, 2020, 2023 to 2025. In testing for 2003 to 2006, 2008 to 2012, 2014 to 2016, 2018, 2021 to 2022, 2026. Not supported for 2007, 2013, 2019.
Misfire count, cylinder 4 PILOT_MIS_4_PCMConfirmed
- Request
22 26 63 - Service 22
DID 2663 - Module
DA0E → 0E - Every
1 s - Testing for 2003 to 2018, 2020 to 2026
Bits 320 to 335 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
Confirmed for 2019. In testing for 2003 to 2016, 2018, 2020 to 2023, 2026. Not supported for 2017, 2024 to 2025.
Misfire count, cylinder 5 PILOT_MISFIRE_5Confirmed
- Request
22 26 63 - Service 22
DID 2663 - Module
DA10 → 10 - Every
1 s - Testing for 2003 to 2016, 2018 to 2019, 2021 to 2022, 2026
Bits 336 to 351 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
Confirmed for 2017, 2020, 2023 to 2025. In testing for 2003 to 2006, 2008 to 2012, 2014 to 2016, 2018, 2021 to 2022, 2026. Not supported for 2007, 2013, 2019.
Misfire count, cylinder 5 PILOT_MISFIRE_5_PCMConfirmed
- Request
22 26 63 - Service 22
DID 2663 - Module
DA0E → 0E - Every
1 s - Testing for 2003 to 2018, 2020 to 2026
Bits 336 to 351 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
Confirmed for 2019. In testing for 2003 to 2016, 2018, 2020 to 2023, 2026. Not supported for 2017, 2024 to 2025.
Misfire count, cylinder 6 PILOT_MISFIRE_6Confirmed
- Request
22 26 63 - Service 22
DID 2663 - Module
DA10 → 10 - Every
1 s - Testing for 2003 to 2016, 2018 to 2019, 2021 to 2022, 2026
Bits 352 to 367 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
Confirmed for 2017, 2020, 2023 to 2025. In testing for 2003 to 2006, 2008 to 2012, 2014 to 2016, 2018, 2021 to 2022, 2026. Not supported for 2007, 2013, 2019.
Misfire count, cylinder 6 PILOT_MISFIRE_6_PCMConfirmed
- Request
22 26 63 - Service 22
DID 2663 - Module
DA0E → 0E - Every
1 s - Testing for 2003 to 2018, 2020 to 2026
Bits 352 to 367 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
Confirmed for 2019. In testing for 2003 to 2016, 2018, 2020 to 2023, 2026. Not supported for 2017, 2024 to 2025.
Oil pressure PILOT_EOP
- Request
22 22 03 - Service 22
DID 2203 - Module
DA1D → 1D - Every
1 s - Testing
Bits 72 to 79 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 kPa
- Unit
- kPa
In testing for 2003 to 2006, 2008 to 2012, 2014 to 2016, 2018, 2021 to 2022, 2026. Not supported for 2007, 2013, 2017, 2019 to 2020, 2023 to 2025.
Variable valve control PILOT_VTEC_CTRLConfirmed
- Request
22 26 12 - Service 22
DID 2612 - Module
DA10 → 10 - Every
250 ms - Testing for 2003 to 2016, 2018 to 2019, 2021 to 2022, 2026
Bits 168 to 175 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
Confirmed for 2017, 2020, 2023 to 2025. In testing for 2003 to 2006, 2008 to 2012, 2014 to 2016, 2018, 2021 to 2022, 2026. Not supported for 2007, 2013, 2019.