Genesis GV60

Engine parameters

The Genesis GV60 has 18 engine parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

Coolant temperature GV60_HVAC_COOLANT_TConfirmed

  • Request22 01 02
  • Service 22DID 0102
  • Module7B3 → 7BB
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 32 to 39 of the reply, 8 bits.

0x6E = 110 → (110 ÷ 2 − 40) = 15 °C

Formula
(val ÷ 2 − 40)
Range
-40 to 87.5 °C
Unit
°C

Confirmed for 2023. In testing for 2022, 2024 to 2026.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Coolant temperature GV60_HVAC_COOLANT_TConfirmed

  • Request22 01 02
  • Service 22DID 0102
  • Module7B3 → 7BB
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 32 to 39 of the reply, 8 bits.

0x6E = 110 → (110 ÷ 2 − 40) = 15 °C

Formula
(val ÷ 2 − 40)
Range
-40 to 87.5 °C
Unit
°C

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Disconnector actuator motor current GV60_DISCONNECTOR_ACTUATOR_MOTOR_CURRENTConfirmed

  • Request22 E0 05
  • Service 22DID E005
  • Module7E2 → 7EA
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 96 to 103 of the reply, 8 bits. The value is signed.

0x00 = 0 → (0 × 2) = 0 A

Formula
(val × 2)
Range
-256 to 254 A
Unit
A

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Disconnector disengage last time GV60_DISCONNECTOR_DISENGAGE_LAST_TIMEConfirmed

  • Request22 E0 05
  • Service 22DID E005
  • Module7E2 → 7EA
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 80 to 87 of the reply, 8 bits.

0x56 = 86 → 86 ms

Formula
val
Range
0 to 255 ms
Unit
ms

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Disconnector end point GV60_DISCONNECTOR_END_POINTConfirmed

  • Request22 E0 05
  • Service 22DID E005
  • Module7E2 → 7EA
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 64 to 79 of the reply, 16 bits. The bytes are in little-endian order.

0x060C = 1548 → (1548 ÷ 128) = 12.09375 mm

Formula
(val ÷ 128)
Range
0 to 511 mm
Unit
mm

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Disconnector inverter PWM duty GV60_DISCONNECTOR_INVERTER_PWM_DUTYConfirmed

  • Request22 E0 05
  • Service 22DID E005
  • Module7E2 → 7EA
  • Every1 s
  • Testing for 2022, 2024 to 2026

Bits 104 to 119 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
(val × 78.125 ÷ 10000)
Range
0 to 100 %
Unit
%

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Disconnector meet point GV60_DISCONNECTOR_MEET_POINTConfirmed

  • Request22 E0 05
  • Service 22DID E005
  • Module7E2 → 7EA
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 48 to 63 of the reply, 16 bits. The bytes are in little-endian order.

0x048D = 1165 → (1165 ÷ 128) = 9.101563 mm

Formula
(val ÷ 128)
Range
0 to 511 mm
Unit
mm

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Disconnector stroke position GV60_DISCONNECTOR_STROKE_POSITIONConfirmed

  • Request22 E0 05
  • Service 22DID E005
  • Module7E2 → 7EA
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 32 to 47 of the reply, 16 bits. The bytes are in little-endian order.

0x0380 = 896 → (896 ÷ 128) = 7 mm

Formula
(val ÷ 128)
Range
0 to 511 mm
Unit
mm

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Disconnector zero count offset GV60_DISCONNECTOR_ZERO_COUNT_OFFSETConfirmed

  • Request22 E0 05
  • Service 22DID E005
  • Module7E2 → 7EA
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 120 to 135 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

0x00D2 = 210 → 210

Formula
val
Range
-32768 to 32767
Unit
Number

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Heat sink temperature GV60_HEAT_SINK_TConfirmed

  • Request22 E0 01
  • Service 22DID E001
  • Module7E3 → 7EB
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 448 to 463 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

0x0838 = 2104 → (2104 ÷ 100) = 21.04 °C

Formula
(val ÷ 100)
Range
-327.68 to 327.67 °C
Unit
°C

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Ignition voltage GV60_IGN_VOLTAGEConfirmed

  • Request22 E0 01
  • Service 22DID E001
  • Module7E3 → 7EB
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 120 to 135 of the reply, 16 bits. The bytes are in little-endian order.

0x3695 = 13973 → (13973 × 10 ÷ 10000) = 13.973 V

Formula
(val × 10 ÷ 10000)
Range
0 to 65.535 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Inverter temperature GV60_HVAC_INVERTER_TConfirmed

  • Request22 01 02
  • Service 22DID 0102
  • Module7B3 → 7BB
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 96 to 103 of the reply, 8 bits.

0x14 = 20 → (20 ÷ 2 − 40) = -30 °C

Formula
(val ÷ 2 − 40)
Range
-40 to 87.5 °C
Unit
°C

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Inverter temperature GV60_INVERTER_TConfirmed

  • Request22 E0 01
  • Service 22DID E001
  • Module7E3 → 7EB
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 216 to 231 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

0x0911 = 2321 → (2321 ÷ 100) = 23.21 °C

Formula
(val ÷ 100)
Range
-327.68 to 327.67 °C
Unit
°C

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Motor actual torque GV60_MOTOR_ACTUAL_TORQUEConfirmed

  • Request22 E0 01
  • Service 22DID E001
  • Module7E3 → 7EB
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 168 to 183 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

0x0000 = 0 → (0 ÷ 10) = 0 N·m

Formula
(val ÷ 10)
Range
-3276.8 to 3276.7 N·m
Unit
N·m

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Motor phase current GV60_MOTOR_PHASE_CURRENT_RMSConfirmed

  • Request22 E0 01
  • Service 22DID E001
  • Module7E3 → 7EB
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 184 to 199 of the reply, 16 bits. The bytes are in little-endian order.

0x001C = 28 → (28 ÷ 10) = 2.8 A

Formula
(val ÷ 10)
Range
0 to 6553.5 A
Unit
A

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Motor RPM GV60_MOTOR_RPMConfirmed

  • Request22 E0 01
  • Service 22DID E001
  • Module7E3 → 7EB
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 136 to 151 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

0x0000 = 0 → 0 rpm

Formula
val
Range
-32768 to 32767 rpm
Unit
rpm

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Motor temperature GV60_MOTOR_TConfirmed

  • Request22 E0 01
  • Service 22DID E001
  • Module7E3 → 7EB
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 200 to 215 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

0x08FE = 2302 → (2302 ÷ 100) = 23.02 °C

Formula
(val ÷ 100)
Range
-327.68 to 327.67 °C
Unit
°C

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Motor-driven power steering current GV60_MDPS_MOTOR_CURRENTConfirmed

  • Request22 01 01
  • Service 22DID 0101
  • Module7D4 → 7DC
  • Every250 ms
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 88 to 95 of the reply, 8 bits. The value is signed.

0x03 = 3 → 3 A

Formula
val
Range
-128 to 127 A
Unit
A

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Nominal torque value GV60_NOMINAL_TORQUE_VALUEConfirmed

  • Request22 E0 01
  • Service 22DID E001
  • Module7E3 → 7EB
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 152 to 167 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

0x0000 = 0 → (0 ÷ 10) = 0 N·m

Formula
(val ÷ 10)
Range
-3276.8 to 3276.7 N·m
Unit
N·m

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Keyboard shortcuts

jk/↓↑
Move down or up through a list or a grid.
hl/←→
Move across a row or between cards.
Enter
Open the focused link.
f
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.