Battery parameters
The Genesis GV60 has 328 battery parameters.
● Confirmed◆ In testing○ Supported× Not supported
A/C charger current GV60_AC_CHARGER_CURRENTConfirmed
- Request
22 E0 03 - Service 22
DID E003 - Module
744 → 74C - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 304 to 319 of the reply, 16 bits.
0x0000 = 0 → (0 ÷ 100) = 0 A
- Formula
(val ÷ 100)- Range
- 0 to 655.35 A
- Unit
- A
Confirmed for 2023. In testing for 2022, 2024 to 2026.
A/C charging counter GV60_HVBAT_AC_CHARGING_COUNTERConfirmed
- Request
22 E0 03 - Service 22
DID E003 - Module
744 → 74C - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 240 to 255 of the reply, 16 bits.
0x004F = 79 → 79
- Formula
val- Range
- 0 to 65535
- Unit
- Number
Confirmed for 2023. In testing for 2022, 2024 to 2026.
A/C charging time GV60_VCMS__AC_CHARGING_TIMEConfirmed
- Request
22 E0 03 - Service 22
DID E003 - Module
744 → 74C - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 272 to 287 of the reply, 16 bits.
0x0115 = 277 → 277 h
- Formula
val- Range
- 0 to 65535 h
- Unit
- h
Confirmed for 2023. In testing for 2022, 2024 to 2026.
A/C charging time, after plug-in GV60_AC_CHARGING_TIME_AFTER_PLUG_INConfirmed
- Request
22 E0 03 - Service 22
DID E003 - Module
744 → 74C - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 336 to 351 of the reply, 16 bits.
0x0000 = 0 → 0 min
- Formula
val- Range
- 0 to 65535 min
- Unit
- min
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Auxiliary battery current GV60_2025_AUX_BATTERY_CURRENT
- Request
22 E1 01 - Service 22
DID E101 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 144 to 159 of the reply, 16 bits.
- Formula
(val ÷ 100 − 327)- Range
- -327 to 328.35 A
- Unit
- A
In testing for 2022, 2024 to 2026. Not supported for 2023.
Auxiliary battery current GV60_AUX_BATTERY_CURRENTConfirmed
- Request
22 E0 11 - Service 22
DID E011 - Module
7E5 → 7ED - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 144 to 159 of the reply, 16 bits.
0x850F = 34063 → (34063 ÷ 100 − 327) = 13.63 A
- Formula
(val ÷ 100 − 327)- Range
- -327 to 328.35 A
- Unit
- A
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Auxiliary battery state of charge GV60_2025_AUX_BATTERY_STATE_OF_CHARGE
- Request
22 E1 01 - Service 22
DID E101 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 160 to 167 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2022, 2024 to 2026. Not supported for 2023.
Auxiliary battery state of charge GV60_AUX_BATTERY_STATE_OF_CHARGEConfirmed
- Request
22 E0 11 - Service 22
DID E011 - Module
7E5 → 7ED - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 160 to 167 of the reply, 8 bits.
0x53 = 83 → 83 %
- Formula
val- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Auxiliary battery temperature GV60_2025_AUX_BATTERY_T
- Request
22 E1 01 - Service 22
DID E101 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 184 to 199 of the reply, 16 bits.
- Formula
(val ÷ 2 − 40)- Range
- -40 to 32727.5 °C
- Unit
- °C
In testing for 2022, 2024 to 2026. Not supported for 2023.
Auxiliary battery temperature GV60_AUX_BATTERY_TConfirmed
- Request
22 E0 11 - Service 22
DID E011 - Module
7E5 → 7ED - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 184 to 199 of the reply, 16 bits.
0x006D = 109 → (109 ÷ 2 − 40) = 14.5 °C
- Formula
(val ÷ 2 − 40)- Range
- -40 to 32727.5 °C
- Unit
- °C
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Auxiliary battery voltage GV60_12V_VConfirmed
Pelican can show this parameter as the starter battery voltage.
- Request
22 E0 04 - Service 22
DID E004 - Module
7E2 → 7EA - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 96 to 111 of the reply, 16 bits. The bytes are in little-endian order.
0x6EE1 = 28385 → (28385 × 4.883 ÷ 10000) = 13.860396 V
- Formula
(val × 4.883 ÷ 10000)- Range
- 0 to 32 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Auxiliary battery voltage GV60_2025_AUX_BATTERY_VOLTAGE
Pelican can show this parameter as the starter battery voltage.
- Request
22 E1 01 - Service 22
DID E101 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 168 to 183 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 6)- Range
- 6 to 71.535 V
- Unit
- V
In testing for 2022, 2024 to 2026. Not supported for 2023.
Auxiliary battery voltage GV60_AUX_BATTERY_VOLTAGE_7E5Confirmed
Pelican can show this parameter as the starter battery voltage.
- Request
22 E0 11 - Service 22
DID E011 - Module
7E5 → 7ED - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 168 to 183 of the reply, 16 bits.
0x1FBA = 8122 → (8122 ÷ 1000 + 6) = 14.122 V
- Formula
(val ÷ 1000 + 6)- Range
- 6 to 71.535 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Auxiliary battery voltage GV60_AUXILLARY_BATTERY_VOLTAGEConfirmed
- Request
22 01 01 - Service 22
DID 0101 - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 232 to 239 of the reply, 8 bits.
0x7C = 124 → (124 ÷ 10) = 12.4 V
- Formula
(val ÷ 10)- Range
- 11 to 14.6 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery current GV60_BATTERY_CURRENTConfirmed
- Request
22 01 01 - Service 22
DID 0101 - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 80 to 95 of the reply, 16 bits. The value is signed.
0x0000 = 0 → (0 ÷ 10) = 0 A
- Formula
(val ÷ 10)- Range
- -230 to 230 A
- Unit
- A
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery DC voltage GV60_BATTERY_DC_VOLTAGEConfirmed
Pelican can show this parameter as the traction battery voltage.
- Request
22 01 01 - Service 22
DID 0101 - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 96 to 111 of the reply, 16 bits.
0x1B22 = 6946 → (6946 ÷ 10) = 694.6 V
- Formula
(val ÷ 10)- Range
- 0 to 1000 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery fan duty feedback GV60_HVBAT_FAN_DUTYConfirmed
- Request
22 01 06 - Service 22
DID 0106 - Module
7E4 → 7EC - Every
5 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 64 to 71 of the reply, 8 bits.
0x00 = 0 → 0 %
- Formula
val- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery fan feedback GV60_BATTERY_FAN_FEEDBACKConfirmed
- Request
22 01 01 - Service 22
DID 0101 - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 224 to 231 of the reply, 8 bits.
0x00 = 0 → 0 Hz
- Formula
val- Range
- 0 to 120 Hz
- Unit
- Hz
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery fan status GV60_BATTERY_FAN_STATUSConfirmed
- Request
22 01 01 - Service 22
DID 0101 - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 216 to 223 of the reply, 8 bits.
0x00 = 0 → 0
- Formula
val- Range
- 0 to 9
- Unit
- Number
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery inlet temperature GV60_BATTERY_INLET_TConfirmed
- Request
22 01 01 - Service 22
DID 0101 - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 176 to 183 of the reply, 8 bits.
0x3F = 63 → (63 − 40) = 23 °C
- Formula
(val − 40)- Range
- -40 to 80 °C
- Unit
- °C
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery management state GV60_BMS_STATEConfirmed
- Request
22 01 06 - Service 22
DID 0106 - Module
7E4 → 7EC - Every
5 s - Testing for 2022, 2024 to 2026
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 15
- Unit
- Number
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery management system ignition GV60_BMS_IGNITIONConfirmed
- Request
22 01 01 - Service 22
DID 0101 - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bit 405 of the reply.
0b0 = 0 → 0
- Formula
val- Range
- 0 to 1
- Unit
- Number
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery management system main relay GV60_BMS_MAIN_RELAYConfirmed
- Request
22 01 01 - Service 22
DID 0101 - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bit 79 of the reply.
0b0 = 0 → 0
- Formula
val- Range
- 0 to 1
- Unit
- Number
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery max temperature GV60_BATTERY_MAX_TConfirmed
- Request
22 01 01 - Service 22
DID 0101 - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 112 to 119 of the reply, 8 bits. The value is signed.
0x16 = 22 → 22 °C
- Formula
val- Range
- -40 to 80 °C
- Unit
- °C
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery min temperature GV60_BATTERY_MIN_TConfirmed
- Request
22 01 01 - Service 22
DID 0101 - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 120 to 127 of the reply, 8 bits. The value is signed.
0x15 = 21 → 21 °C
- Formula
val- Range
- -40 to 80 °C
- Unit
- °C
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery pack B01 GV60_BATTERY_PACK_B01Confirmed
- Request
22 01 01 - Service 22
DID 0101 - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 128 to 135 of the reply, 8 bits. The value is signed.
0x16 = 22 → 22 °C
- Formula
val- Range
- -40 to 80 °C
- Unit
- °C
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery pack B02 GV60_BATTERY_PACK_B02Confirmed
- Request
22 01 01 - Service 22
DID 0101 - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 136 to 143 of the reply, 8 bits. The value is signed.
0x16 = 22 → 22 °C
- Formula
val- Range
- -40 to 80 °C
- Unit
- °C
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery pack B03 GV60_BATTERY_PACK_B03Confirmed
- Request
22 01 01 - Service 22
DID 0101 - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 144 to 151 of the reply, 8 bits. The value is signed.
0x15 = 21 → 21 °C
- Formula
val- Range
- -40 to 80 °C
- Unit
- °C
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery pack B04 GV60_BATTERY_PACK_B04Confirmed
- Request
22 01 01 - Service 22
DID 0101 - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 152 to 159 of the reply, 8 bits. The value is signed.
0x16 = 22 → 22 °C
- Formula
val- Range
- -40 to 80 °C
- Unit
- °C
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery pack B05 GV60_BATTERY_PACK_B05Confirmed
- Request
22 01 01 - Service 22
DID 0101 - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 160 to 167 of the reply, 8 bits. The value is signed.
0x15 = 21 → 21 °C
- Formula
val- Range
- -40 to 80 °C
- Unit
- °C
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery pack B17 GV60_BATTERY_PACK_B17Confirmed
- Request
22 01 11 - Service 22
DID 0111 - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 208 to 215 of the reply, 8 bits. The value is signed.
0x11 = 17 → 17 °C
- Formula
val- Range
- -40 to 80 °C
- Unit
- °C
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery pack B18 GV60_BATTERY_PACK_B18Confirmed
- Request
22 01 11 - Service 22
DID 0111 - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 216 to 223 of the reply, 8 bits. The value is signed.
0x11 = 17 → 17 °C
- Formula
val- Range
- -40 to 80 °C
- Unit
- °C
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery temperature at the power relay assembly GV60_HVBAT_PRA_TConfirmed
- Request
22 01 06 - Service 22
DID 0106 - Module
7E4 → 7EC - Every
5 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 160 to 167 of the reply, 8 bits. The value is signed.
0x06 = 6 → (6 × 2) = 12 °C
- Formula
(val × 2)- Range
- -256 to 254 °C
- Unit
- °C
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery temperature at WCS input GV60_HVBAT_WCS_INLET_TConfirmed
- Request
22 01 06 - Service 22
DID 0106 - Module
7E4 → 7EC - Every
5 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 32 to 39 of the reply, 8 bits. The value is signed.
0x0E = 14 → 14 °C
- Formula
val- Range
- -128 to 127 °C
- Unit
- °C
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery work time total GV60_BATTERY_WORK_TIME_TOTAL_SECConfirmed
- Request
22 01 01 - Service 22
DID 0101 - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 368 to 399 of the reply, 32 bits.
0x02A4E61E = 44361246 → 44,361,246 s
- Formula
val- Range
- 0 to 4294967295 s
- Unit
- s
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Charge mode A/C maximum current limit GV60_CHARGE_MODE_AC_MAXIMUM_CURRENT_LIMITConfirmed
- Request
22 E0 01 - Service 22
DID E001 - Module
7E5 → 7ED - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 96 to 111 of the reply, 16 bits.
0x0000 = 0 → (0 ÷ 10) = 0 A
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 A
- Unit
- A
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Charge mode DC maximum current limit GV60_CHARGE_MODE_DC_MAXIMUM_CURRENT_LIMITConfirmed
- Request
22 E0 01 - Service 22
DID E001 - Module
7E5 → 7ED - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 80 to 95 of the reply, 16 bits.
0x0000 = 0 → (0 ÷ 10) = 0 A
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 A
- Unit
- A
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Charge mode DC target voltage GV60_CHARGE_MODE_DC_TARGET_VOLTAGEConfirmed
- Request
22 E0 01 - Service 22
DID E001 - Module
7E5 → 7ED - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 64 to 79 of the reply, 16 bits.
0x2040 = 8256 → (8256 ÷ 10) = 825.6 V
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Charging? GV60_HV_CHARGINGConfirmed
Pelican can show this parameter as the charging state.
- Request
22 01 01 - Service 22
DID 0101 - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bit 72 of the reply.
0b0 = 0 → 0
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Control pilot duty cycle GV60_HVBAT_CP_DUTY_CYCLEConfirmed
- Request
22 E0 03 - Service 22
DID E003 - Module
744 → 74C - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 56 to 71 of the reply, 16 bits.
0x0000 = 0 → (0 ÷ 10) = 0 %
- Formula
(val ÷ 10)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Control pilot voltage GV60_HVBAT_CP_VOLTAGEConfirmed
- Request
22 E0 03 - Service 22
DID E003 - Module
744 → 74C - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 48 to 55 of the reply, 8 bits.
0x5A = 90 → (90 ÷ 10) = 9 V
- Formula
(val ÷ 10)- Range
- 0 to 25.5 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Cumulative charge current GV60_CUMULATIVE_CHARGE_CURRENTConfirmed
- Request
22 01 01 - Service 22
DID 0101 - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 240 to 271 of the reply, 32 bits.
0x000459DE = 285150 → (285150 ÷ 10) = 28,515 Ah
- Formula
(val ÷ 10)- Range
- 0 to 429496729.5 Ah
- Unit
- Ah
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Cumulative DC charging time GV60_DC_CHRG_TIMEConfirmed
- Request
22 E0 03 - Service 22
DID E003 - Module
744 → 74C - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 288 to 303 of the reply, 16 bits.
0x007D = 125 → 125 h
- Formula
val- Range
- 0 to 65535 h
- Unit
- h
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Cumulative discharge current GV60_CUMULATIVE_DISCHARGE_CURRENTConfirmed
- Request
22 01 01 - Service 22
DID 0101 - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 272 to 303 of the reply, 32 bits.
0x000433D2 = 275410 → (275410 ÷ 10) = 27,541 Ah
- Formula
(val ÷ 10)- Range
- 0 to 429496729.5 Ah
- Unit
- Ah
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Cumulative energy charged GV60_CUMULATIVE_ENERGY_CHARGEDConfirmed
- Request
22 01 01 - Service 22
DID 0101 - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 304 to 335 of the reply, 32 bits.
0x00034567 = 214375 → (214375 ÷ 10) = 21,437.5 kWh
- Formula
(val ÷ 10)- Range
- 0 to 429496729.5 kWh
- Unit
- kWh
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Cumulative energy discharged GV60_CUMULATIVE_ENERGY_DISCHARGEDConfirmed
- Request
22 01 01 - Service 22
DID 0101 - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 336 to 367 of the reply, 32 bits.
0x00030065 = 196709 → (196709 ÷ 10) = 19,670.9 kWh
- Formula
(val ÷ 10)- Range
- 0 to 429496729.5 kWh
- Unit
- kWh
Confirmed for 2023. In testing for 2022, 2024 to 2026.
DC charger current capability GV60_DC_CHARGER_CURRENT_CAPABILITYConfirmed
- Request
22 E0 03 - Service 22
DID E003 - Module
744 → 74C - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 320 to 335 of the reply, 16 bits.
0x0D02 = 3330 → (3330 ÷ 100) = 33.3 A
- Formula
(val ÷ 100)- Range
- 0 to 655.35 A
- Unit
- A
Confirmed for 2023. In testing for 2022, 2024 to 2026.
DC charging counter GV60_HVBAT_CHRG_CNTConfirmed
- Request
22 E0 03 - Service 22
DID E003 - Module
744 → 74C - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 256 to 271 of the reply, 16 bits.
0x0133 = 307 → 307
- Formula
val- Range
- 0 to 65535
- Unit
- Number
Confirmed for 2023. In testing for 2022, 2024 to 2026.
DC charging time, after plug-in GV60_DC_CHARGING_TIME_AFTER_PLUG_INConfirmed
- Request
22 E0 03 - Service 22
DID E003 - Module
744 → 74C - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 352 to 367 of the reply, 16 bits.
0x001A = 26 → 26 min
- Formula
val- Range
- 0 to 65535 min
- Unit
- min
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Discharge mode A/C maximum current limit GV60_DISCHARGE_MODE_AC_MAXIMUM_CURRENT_LIMITConfirmed
- Request
22 E0 01 - Service 22
DID E001 - Module
7E5 → 7ED - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 136 to 143 of the reply, 8 bits.
0x00 = 0 → 0 A
- Formula
val- Range
- 0 to 255 A
- Unit
- A
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Discharge mode A/C target voltage GV60_DISCHARGE_MODE_V2L_AC_TARGET_VOLTAGEConfirmed
- Request
22 E0 01 - Service 22
DID E001 - Module
7E5 → 7ED - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 112 to 119 of the reply, 8 bits.
0x00 = 0 → 0 V
- Formula
val- Range
- 0 to 255 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Discharge mode DC maximum current limit GV60_DISCHARGE_MODE_DC_MAXIMUM_CURRENT_LIMITConfirmed
- Request
22 E0 01 - Service 22
DID E001 - Module
7E5 → 7ED - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 128 to 135 of the reply, 8 bits.
0x32 = 50 → 50 A
- Formula
val- Range
- 0 to 255 A
- Unit
- A
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Electric oil pump, actual speed GV60_EOP_ACTUAL_SPEEDConfirmed
- Request
22 E0 09 - Service 22
DID E009 - Module
7E3 → 7EB - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 112 to 119 of the reply, 8 bits.
0x00 = 0 → (0 × 20) = 0 rpm
- Formula
(val × 20)- Range
- 0 to 5100 rpm
- Unit
- rpm
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Electric oil pump, commanded speed GV60_EOP_COMMANDED_SPEEDConfirmed
- Request
22 E0 09 - Service 22
DID E009 - Module
7E3 → 7EB - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 152 to 159 of the reply, 8 bits.
0x00 = 0 → (0 × 20) = 0 rpm
- Formula
(val × 20)- Range
- 0 to 5100 rpm
- Unit
- rpm
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Electric oil pump, current DC GV60_EOP_CURRENT_DCConfirmed
- Request
22 E0 09 - Service 22
DID E009 - Module
7E3 → 7EB - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 176 to 183 of the reply, 8 bits.
0x00 = 0 → 0 A
- Formula
val- Range
- 0 to 255 A
- Unit
- A
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Electric oil pump, current IQ GV60_EOP_CURRENT_IQConfirmed
- Request
22 E0 09 - Service 22
DID E009 - Module
7E3 → 7EB - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 184 to 191 of the reply, 8 bits.
0x00 = 0 → 0 A
- Formula
val- Range
- 0 to 255 A
- Unit
- A
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Electric vehicle supply equipment, target current GV60_HVBAT_TARGET_CURRConfirmed
- Request
22 E0 03 - Service 22
DID E003 - Module
744 → 74C - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 144 to 159 of the reply, 16 bits.
0x0000 = 0 → (0 ÷ 10) = 0 A
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 A
- Unit
- A
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Electric water pump, actual rotation speed GV60_EWP_ACTUAL_ROTATION_SPEEDConfirmed
- Request
22 E0 09 - Service 22
DID E009 - Module
7E3 → 7EB - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 96 to 103 of the reply, 8 bits.
0x47 = 71 → (71 × 24) = 1,704 rpm
- Formula
(val × 24)- Range
- 0 to 6120 rpm
- Unit
- rpm
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Electric water pump, commanded rotation speed GV60_EWP_COMMANDED_ROTATION_SPEEDConfirmed
- Request
22 E0 09 - Service 22
DID E009 - Module
7E3 → 7EB - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 88 to 95 of the reply, 8 bits.
0x48 = 72 → (72 × 24) = 1,728 rpm
- Formula
(val × 24)- Range
- 0 to 6120 rpm
- Unit
- rpm
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Electric water pump, current DC GV60_EWP_CURRENT_DCConfirmed
- Request
22 E0 09 - Service 22
DID E009 - Module
7E3 → 7EB - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 56 to 63 of the reply, 8 bits.
0x04 = 4 → (4 ÷ 10) = 0.4 A
- Formula
(val ÷ 10)- Range
- 0 to 25.5 A
- Unit
- A
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Electric water pump, voltage DC GV60_EWP_VOLTAGE_DCConfirmed
- Request
22 E0 09 - Service 22
DID E009 - Module
7E3 → 7EB - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 64 to 71 of the reply, 8 bits.
0x8C = 140 → (140 ÷ 10) = 14 V
- Formula
(val ÷ 10)- Range
- 0 to 25.5 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
High voltage battery, max current GV60_HVBAT_EV_MAX_CURRENTConfirmed
- Request
22 E0 03 - Service 22
DID E003 - Module
744 → 74C - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 176 to 191 of the reply, 16 bits.
0x0DAC = 3500 → (3500 ÷ 10) = 350 A
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 A
- Unit
- A
Confirmed for 2023. In testing for 2022, 2024 to 2026.
High voltage battery, max voltage GV60_HVBAT_EV_MAX_VOLTAGEConfirmed
- Request
22 E0 03 - Service 22
DID E003 - Module
744 → 74C - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 160 to 175 of the reply, 16 bits.
0x2040 = 8256 → (8256 ÷ 10) = 825.6 V
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
High voltage battery, state of charge GV60_HVBAT_SOC_VCMSConfirmed
Pelican can show this parameter as the state of charge.
- Request
22 E0 03 - Service 22
DID E003 - Module
744 → 74C - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 120 to 127 of the reply, 8 bits.
0xB4 = 180 → (180 ÷ 2) = 90 %
- Formula
(val ÷ 2)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2023. In testing for 2022, 2024 to 2026.
High voltage battery, target current GV60_HVBAT_BMS_TARGET_CURRENTConfirmed
- Request
22 E0 03 - Service 22
DID E003 - Module
744 → 74C - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 208 to 223 of the reply, 16 bits.
0x0000 = 0 → (0 ÷ 10) = 0 A
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 A
- Unit
- A
Confirmed for 2023. In testing for 2022, 2024 to 2026.
High voltage battery, target voltage GV60_HVBAT_BMS_TARGET_VOLTAGEConfirmed
- Request
22 E0 03 - Service 22
DID E003 - Module
744 → 74C - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 192 to 207 of the reply, 16 bits.
0x2040 = 8256 → (8256 ÷ 10) = 825.6 V
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
High voltage battery, target voltage GV60_HVBAT_TARGET_VOLTConfirmed
- Request
22 E0 03 - Service 22
DID E003 - Module
744 → 74C - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 128 to 143 of the reply, 16 bits.
0x2040 = 8256 → (8256 ÷ 10) = 825.6 V
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
High voltage battery, voltage GV60_HVBAT_HV_BATTERY_VOLTAGEConfirmed
Pelican can show this parameter as the traction battery voltage.
- Request
22 E0 03 - Service 22
DID E003 - Module
744 → 74C - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 104 to 119 of the reply, 16 bits.
0x1EC9 = 7881 → (7881 ÷ 10) = 788.1 V
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
HV battery charge GV60_HVBAT_SOC_DISPConfirmed
Pelican can show this parameter as the state of charge.
- Request
22 01 05 - Service 22
DID 0105 - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 248 to 255 of the reply, 8 bits.
0xA9 = 169 → (169 ÷ 2) = 84.5 %
- Formula
(val ÷ 2)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2023. In testing for 2022, 2024 to 2026.
HV battery charge, dashboard GV60_HVBAT_SOCConfirmed
Pelican can show this parameter as the state of charge.
- Request
22 01 01 - Service 22
DID 0101 - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 32 to 39 of the reply, 8 bits.
0x46 = 70 → (70 ÷ 2) = 35 %
- Formula
(val ÷ 2)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2023. In testing for 2022, 2024 to 2026.
HV battery remaining energy GV60_HVBAT_WHConfirmed
- Request
22 01 05 - Service 22
DID 0105 - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 224 to 239 of the reply, 16 bits.
0x7750 = 30544 → (30544 × 2 ÷ 1000) = 61.088 kWh
- Formula
(val × 2 ÷ 1000)- Range
- 0 to 100 kWh
- Unit
- kWh
Confirmed for 2023. In testing for 2022, 2024 to 2026.
HV battery state of health GV60_HVBAT_SOHConfirmed
Pelican can show this parameter as the state of health.
- Request
22 01 05 - Service 22
DID 0105 - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 200 to 215 of the reply, 16 bits.
0x03E8 = 1000 → (1000 ÷ 10) = 100 %
- Formula
(val ÷ 10)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Inverter capacitor voltage GV60_INVERTER_CAPACITOR_VOLTAGEConfirmed
- Request
22 01 01 - Service 22
DID 0101 - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 408 to 423 of the reply, 16 bits.
0x01DF = 479 → 479 V
- Formula
val- Range
- 0 to 500 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Isolation resistance GV60_ISOLATION_RESISTANCEConfirmed
- Request
22 01 01 - Service 22
DID 0101 - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Bits 456 to 471 of the reply, 16 bits.
- Formula
val- Range
- 0 to 1000 kΩ
- Unit
- kΩ
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Low-voltage dc-dc converter, input voltage GV60_2025_LDC_INPUT_VOLTAGE
- Request
22 E1 01 - Service 22
DID E101 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 112 to 127 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 V
- Unit
- V
In testing for 2022, 2024 to 2026. Not supported for 2023.
Low-voltage dc-dc converter, input voltage GV60_LDC_INPUT_VOLTAGEConfirmed
- Request
22 E0 11 - Service 22
DID E011 - Module
7E5 → 7ED - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 112 to 127 of the reply, 16 bits.
0x1DC3 = 7619 → (7619 ÷ 10) = 761.9 V
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Low-voltage dc-dc converter, output current GV60_2025_LDC_OUTPUT_CURRENT
- Request
22 E1 01 - Service 22
DID E101 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 96 to 111 of the reply, 16 bits.
- Formula
(val × 10 ÷ 1000)- Range
- 0 to 655.35 A
- Unit
- A
In testing for 2022, 2024 to 2026. Not supported for 2023.
Low-voltage dc-dc converter, output current GV60_LDC_OUTPUT_CURRENTConfirmed
- Request
22 E0 11 - Service 22
DID E011 - Module
7E5 → 7ED - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 96 to 111 of the reply, 16 bits.
0x13E5 = 5093 → (5093 × 10 ÷ 1000) = 50.93 A
- Formula
(val × 10 ÷ 1000)- Range
- 0 to 655.35 A
- Unit
- A
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Low-voltage dc-dc converter, output voltage GV60_2025_LDC_OUTPUT_VOLTAGE
- Request
22 E1 01 - Service 22
DID E101 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 80 to 95 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2022, 2024 to 2026. Not supported for 2023.
Low-voltage dc-dc converter, output voltage GV60_LDC_OUTPUT_VOLTAGEConfirmed
- Request
22 E0 11 - Service 22
DID E011 - Module
7E5 → 7ED - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 80 to 95 of the reply, 16 bits.
0x3884 = 14468 → (14468 ÷ 1000) = 14.468 V
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Low-voltage dc-dc converter, temperature GV60_2025_LDC_T
- Request
22 E1 01 - Service 22
DID E101 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 72 to 79 of the reply, 8 bits.
- Formula
(val − 100)- Range
- -100 to 155 °C
- Unit
- °C
In testing for 2022, 2024 to 2026. Not supported for 2023.
Low-voltage dc-dc converter, temperature GV60_LDC_TConfirmed
- Request
22 E0 11 - Service 22
DID E011 - Module
7E5 → 7ED - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 72 to 79 of the reply, 8 bits.
0x77 = 119 → (119 − 100) = 19 °C
- Formula
(val − 100)- Range
- -100 to 155 °C
- Unit
- °C
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Maximum cell voltage GV60_MAXIMUM_CELL_VOLTAGEConfirmed
- Request
22 01 01 - Service 22
DID 0101 - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 184 to 191 of the reply, 8 bits.
0xB4 = 180 → (180 ÷ 50) = 3.6 V
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Maximum cell voltage no GV60_MAXIMUM_CELL_VOLTAGE_NOConfirmed
- Request
22 01 01 - Service 22
DID 0101 - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 192 to 199 of the reply, 8 bits.
0x03 = 3 → 3
- Formula
val- Range
- 0 to 98
- Unit
- Number
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Minimum cell voltage GV60_MINIMUM_CELL_VOLTAGEConfirmed
- Request
22 01 01 - Service 22
DID 0101 - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 200 to 207 of the reply, 8 bits.
0xB4 = 180 → (180 ÷ 50) = 3.6 V
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Minimum cell voltage no GV60_MINIMUM_CELL_VOLTAGE_NOConfirmed
- Request
22 01 01 - Service 22
DID 0101 - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Bits 208 to 215 of the reply, 8 bits.
- Formula
val- Range
- 0 to 98
- Unit
- Number
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Normal charge port GV60_NORMAL_CHARGE_PORTConfirmed
- Request
22 01 01 - Service 22
DID 0101 - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bit 74 of the reply.
0b0 = 0 → 0
- Formula
val- Range
- 0 to 1
- Unit
- Number
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Normal charging energy, total GV60_NORMAL_CHARGING_ENERGY_TOTConfirmed
- Request
22 01 11 - Service 22
DID 0111 - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 96 to 127 of the reply, 32 bits.
0x00000603 = 1539 → 1,539 kWh
- Formula
val- Range
- 0 to 4294967295 kWh
- Unit
- kWh
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Normal charging, count GV60_NORMAL_CHARGING_COUNTConfirmed
- Request
22 01 11 - Service 22
DID 0111 - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 32 to 63 of the reply, 32 bits.
0x00000070 = 112 → 112
- Formula
val- Range
- 0 to 4294967295
- Unit
- Number
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Proximity detection voltage GV60_HVBAT_PD_VOLTAGEConfirmed
- Request
22 E0 03 - Service 22
DID E003 - Module
744 → 74C - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 88 to 103 of the reply, 16 bits.
0x05D2 = 1490 → (1490 × 10 ÷ 10000) = 1.49 V
- Formula
(val × 10 ÷ 10000)- Range
- 0 to 65.535 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Quick charging energy, total GV60_QUICK_CHARGING_ENERGY_TOTConfirmed
- Request
22 01 11 - Service 22
DID 0111 - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 128 to 159 of the reply, 32 bits.
0x000015AC = 5548 → 5,548 kWh
- Formula
val- Range
- 0 to 4294967295 kWh
- Unit
- kWh
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Quick charging, count GV60_QUICK_CHARGING_COUNTConfirmed
- Request
22 01 11 - Service 22
DID 0111 - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 64 to 95 of the reply, 32 bits.
0x0000017F = 383 → 383
- Formula
val- Range
- 0 to 4294967295
- Unit
- Number
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Rapid charge port GV60_RAPID_CHARGE_PORTConfirmed
- Request
22 01 01 - Service 22
DID 0101 - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bit 73 of the reply.
0b0 = 0 → 0
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery › Charging
400V relay on/off request GV60_400V_RELAY_ON_OFF_REQUESTConfirmed
- Request
22 E0 04 - Service 22
DID E004 - Module
744 → 74C - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bit 43 of the reply.
0b0 = 0 → 0
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
Confirmed for 2023. In testing for 2022, 2024 to 2026.
400V relay status GV60_400V_RELAY_STATUSConfirmed
- Request
22 E0 04 - Service 22
DID E004 - Module
744 → 74C - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bit 42 of the reply.
0b0 = 0 → 0
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
Confirmed for 2023. In testing for 2022, 2024 to 2026.
AC charging state GV60_AC_CHRG_STATEConfirmed
- Request
22 E0 01 - Service 22
DID E001 - Module
744 → 74C - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bit 141 of the reply.
0b0 = 0 → 0
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
Confirmed for 2023. In testing for 2022, 2024 to 2026.
AC inlet temperature 1 GV60_AC_INLET_T_1Confirmed
- Request
22 E0 04 - Service 22
DID E004 - Module
744 → 74C - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 80 to 87 of the reply, 8 bits.
0x42 = 66 → (66 − 50) = 16 °C
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Auxiliary battery voltage GV60_AUX_BATTERY_VOLTAGEConfirmed
- Request
22 E0 01 - Service 22
DID E001 - Module
744 → 74C - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 88 to 103 of the reply, 16 bits.
0x04BB = 1211 → (1211 ÷ 100) = 12.11 V
- Formula
(val ÷ 100)- Range
- 0 to 655.35 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery main relay status GV60_BATTERY_MAIN_RELAY_STATUSConfirmed
- Request
22 E0 04 - Service 22
DID E004 - Module
744 → 74C - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bit 37 of the reply.
0b0 = 0 → 0
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Charging socket connected GV60_CHARGING_SOCKET_CONNECTEDConfirmed
- Request
22 E0 04 - Service 22
DID E004 - Module
744 → 74C - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bit 38 of the reply.
0b0 = 0 → 0
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
Confirmed for 2023. In testing for 2022, 2024 to 2026.
DC charging state GV60_DC_CHRG_STATEConfirmed
- Request
22 E0 01 - Service 22
DID E001 - Module
744 → 74C - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bit 140 of the reply.
0b0 = 0 → 0
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
Confirmed for 2023. In testing for 2022, 2024 to 2026.
DC inlet temperature 1 GV60_DC_INLET_T_1Confirmed
- Request
22 E0 04 - Service 22
DID E004 - Module
744 → 74C - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 64 to 71 of the reply, 8 bits.
0x42 = 66 → (66 − 50) = 16 °C
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
Confirmed for 2023. In testing for 2022, 2024 to 2026.
DC inlet temperature 2 GV60_DC_INLET_T_2Confirmed
- Request
22 E0 04 - Service 22
DID E004 - Module
744 → 74C - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 72 to 79 of the reply, 8 bits.
0x42 = 66 → (66 − 50) = 16 °C
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Electric vehicle supply equipment, current GV60_EVSE_CConfirmed
- Request
22 E0 02 - Service 22
DID E002 - Module
744 → 74C - Every
250 ms - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 152 to 167 of the reply, 16 bits.
0x0000 = 0 → (0 ÷ 10) = 0 A
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 A
- Unit
- A
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Electric vehicle supply equipment, current, max GV60_EVSE_MAXIMUM_CURRENT_VALUEConfirmed
- Request
22 E0 02 - Service 22
DID E002 - Module
744 → 74C - Every
250 ms - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 88 to 103 of the reply, 16 bits.
0x0000 = 0 → (0 ÷ 10) = 0 A
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 A
- Unit
- A
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Electric vehicle supply equipment, current, min GV60_EVSE_MINIMUM_CURRENT_VALUEConfirmed
- Request
22 E0 02 - Service 22
DID E002 - Module
744 → 74C - Every
250 ms - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 120 to 135 of the reply, 16 bits.
0x0000 = 0 → (0 ÷ 10) = 0 A
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 A
- Unit
- A
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Electric vehicle supply equipment, power, delivered GV60_EVSE_DELIVERED_POWER_VALUEConfirmed
- Request
22 E0 02 - Service 22
DID E002 - Module
744 → 74C - Every
250 ms - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 184 to 199 of the reply, 16 bits.
0x0000 = 0 → (0 × 10 ÷ 1000) = 0 kWh
- Formula
(val × 10 ÷ 1000)- Range
- 0 to 655.35 kWh
- Unit
- kWh
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Electric vehicle supply equipment, power, main GV60_EVSE_MAIN_POWERConfirmed
- Request
22 E0 02 - Service 22
DID E002 - Module
744 → 74C - Every
250 ms - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 216 to 223 of the reply, 8 bits.
0x00 = 0 → 0 kW
- Formula
val- Range
- 0 to 255 kW
- Unit
- kW
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Electric vehicle supply equipment, power, max GV60_EVSE_MAXIMUM_POWER_VALUEConfirmed
- Request
22 E0 02 - Service 22
DID E002 - Module
744 → 74C - Every
250 ms - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 200 to 215 of the reply, 16 bits.
0x0000 = 0 → (0 × 10) = 0 W
- Formula
(val × 10)- Range
- 0 to 655350 W
- Unit
- W
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Electric vehicle supply equipment, regulation tolerance GV60_EVSE_CURRENT_REGULATION_TOLERANCE_VALUEConfirmed
- Request
22 E0 02 - Service 22
DID E002 - Module
744 → 74C - Every
250 ms - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 176 to 183 of the reply, 8 bits.
0x00 = 0 → (0 − 50) = -50 A
- Formula
(val − 50)- Range
- -50 to 205 A
- Unit
- A
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Electric vehicle supply equipment, voltage GV60_EVSE_VConfirmed
- Request
22 E0 02 - Service 22
DID E002 - Module
744 → 74C - Every
250 ms - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 136 to 151 of the reply, 16 bits.
0x0000 = 0 → (0 ÷ 10) = 0 V
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Electric vehicle supply equipment, voltage, max GV60_EVSE_MAXIMUM_VOLTAGE_VALUEConfirmed
- Request
22 E0 02 - Service 22
DID E002 - Module
744 → 74C - Every
250 ms - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 72 to 87 of the reply, 16 bits.
0x0FA0 = 4000 → (4000 ÷ 10) = 400 V
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Electric vehicle supply equipment, voltage, min GV60_EVSE_MINIMUM_VOLTAGE_VALUEConfirmed
- Request
22 E0 02 - Service 22
DID E002 - Module
744 → 74C - Every
250 ms - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 104 to 119 of the reply, 16 bits.
0x0000 = 0 → (0 ÷ 10) = 0 V
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Estimated charging power GV60_ESTIMATED_CHRG_POWERConfirmed
- Request
22 E0 01 - Service 22
DID E001 - Module
744 → 74C - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 224 to 239 of the reply, 16 bits.
0x0000 = 0 → (0 × 10 − 50) = -50 W
- Formula
(val × 10 − 50)- Range
- -50 to 655300 W
- Unit
- W
Confirmed for 2023. In testing for 2022, 2024 to 2026.
On-board charger, AC current a GV60_OBC_AC_CURRENT_A_RMSConfirmed
- Request
22 E0 02 - Service 22
DID E002 - Module
7E5 → 7ED - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 104 to 119 of the reply, 16 bits. The value is signed.
0x0000 = 0 → (0 ÷ 100) = 0 A
- Formula
(val ÷ 100)- Range
- -327.68 to 327.67 A
- Unit
- A
Confirmed for 2023. In testing for 2022, 2024 to 2026.
On-board charger, AC current b GV60_OBC_AC_CURRENT_B_RMSConfirmed
- Request
22 E0 02 - Service 22
DID E002 - Module
7E5 → 7ED - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 120 to 135 of the reply, 16 bits. The value is signed.
0x0000 = 0 → (0 ÷ 100) = 0 A
- Formula
(val ÷ 100)- Range
- -327.68 to 327.67 A
- Unit
- A
Confirmed for 2023. In testing for 2022, 2024 to 2026.
On-board charger, AC frequency GV60_OBC_AC_FREQUENCYConfirmed
- Request
22 E0 02 - Service 22
DID E002 - Module
7E5 → 7ED - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 80 to 87 of the reply, 8 bits.
0x00 = 0 → 0 Hz
- Formula
val- Range
- 0 to 255 Hz
- Unit
- Hz
Confirmed for 2023. In testing for 2022, 2024 to 2026.
On-board charger, AC input current sensor a signal voltage GV60_OBC_AC_INPUT_CURRENT_SENSOR_A_SIGNAL_VOLTAGEConfirmed
- Request
22 E0 02 - Service 22
DID E002 - Module
7E5 → 7ED - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 296 to 311 of the reply, 16 bits.
0x0000 = 0 → (0 ÷ 100) = 0 V
- Formula
(val ÷ 100)- Range
- 0 to 655.35 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
On-board charger, AC input current sensor b signal voltage GV60_OBC_AC_INPUT_CURRENT_SENSOR_B_SIGNAL_VOLTAGEConfirmed
- Request
22 E0 02 - Service 22
DID E002 - Module
7E5 → 7ED - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 312 to 327 of the reply, 16 bits.
0x0000 = 0 → (0 ÷ 100) = 0 V
- Formula
(val ÷ 100)- Range
- 0 to 655.35 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
On-board charger, AC total current GV60_OBC_AC_TOTAL_CURRENT_RMSConfirmed
- Request
22 E0 02 - Service 22
DID E002 - Module
7E5 → 7ED - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 88 to 103 of the reply, 16 bits. The value is signed.
0x0000 = 0 → (0 ÷ 100) = 0 A
- Formula
(val ÷ 100)- Range
- -327.68 to 327.67 A
- Unit
- A
Confirmed for 2023. In testing for 2022, 2024 to 2026.
On-board charger, AC voltage a GV60_OBC_AC_VOLTAGE_A_RMSConfirmed
- Request
22 E0 02 - Service 22
DID E002 - Module
7E5 → 7ED - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 32 to 47 of the reply, 16 bits.
0x0000 = 0 → (0 ÷ 10) = 0 V
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
On-board charger, AC voltage b GV60_OBC_AC_VOLTAGE_B_RMSConfirmed
- Request
22 E0 02 - Service 22
DID E002 - Module
7E5 → 7ED - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 48 to 63 of the reply, 16 bits.
0x0000 = 0 → (0 ÷ 10) = 0 V
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
On-board charger, charge mode DC target current GV60_OBC_CHARGE_MODE_DC_TARGET_CURRENTConfirmed
- Request
22 E0 03 - Service 22
DID E003 - Module
7E5 → 7ED - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 80 to 95 of the reply, 16 bits.
0x0000 = 0 → (0 ÷ 10) = 0 A
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 A
- Unit
- A
Confirmed for 2023. In testing for 2022, 2024 to 2026.
On-board charger, charge mode DC target voltage GV60_OBC_CHARGE_MODE_DC_TARGET_VOLTAGEConfirmed
- Request
22 E0 03 - Service 22
DID E003 - Module
7E5 → 7ED - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 64 to 79 of the reply, 16 bits.
0x1B28 = 6952 → (6952 ÷ 10) = 695.2 V
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
On-board charger, charging AC current GV60_OBC_CHRG_AC_CURRENTConfirmed
- Request
22 E0 01 - Service 22
DID E001 - Module
744 → 74C - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 184 to 199 of the reply, 16 bits.
0x0000 = 0 → (0 ÷ 10) = 0 A
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 A
- Unit
- A
Confirmed for 2023. In testing for 2022, 2024 to 2026.
On-board charger, charging AC voltage GV60_OBC_CHRG_AC_VOLTAGEConfirmed
- Request
22 E0 01 - Service 22
DID E001 - Module
744 → 74C - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 200 to 207 of the reply, 8 bits.
0x00 = 0 → 0 V
- Formula
val- Range
- 0 to 255 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
On-board charger, charging DC current GV60_OBC_CHRG_DC_CURRENTConfirmed
- Request
22 E0 01 - Service 22
DID E001 - Module
744 → 74C - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 168 to 183 of the reply, 16 bits.
0x0000 = 0 → (0 ÷ 10) = 0 A
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 A
- Unit
- A
Confirmed for 2023. In testing for 2022, 2024 to 2026.
On-board charger, charging DC voltage GV60_OBC_CHRG_DC_VOLTAGEConfirmed
- Request
22 E0 01 - Service 22
DID E001 - Module
744 → 74C - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 152 to 167 of the reply, 16 bits.
0x0000 = 0 → (0 ÷ 10) = 0 V
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
On-board charger, DC current a GV60_OBC_DC_CURRENT_A_RMSConfirmed
- Request
22 E0 02 - Service 22
DID E002 - Module
7E5 → 7ED - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 184 to 199 of the reply, 16 bits. The value is signed.
0x0000 = 0 → (0 ÷ 100) = 0 A
- Formula
(val ÷ 100)- Range
- -327.68 to 327.67 A
- Unit
- A
Confirmed for 2023. In testing for 2022, 2024 to 2026.
On-board charger, DC current b GV60_OBC_DC_CURRENT_B_RMSConfirmed
- Request
22 E0 02 - Service 22
DID E002 - Module
7E5 → 7ED - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 200 to 215 of the reply, 16 bits. The value is signed.
0x0000 = 0 → (0 ÷ 100) = 0 A
- Formula
(val ÷ 100)- Range
- -327.68 to 327.67 A
- Unit
- A
Confirmed for 2023. In testing for 2022, 2024 to 2026.
On-board charger, DC current total GV60_OBC_DC_CURRENT_TOTAL_RMSConfirmed
- Request
22 E0 02 - Service 22
DID E002 - Module
7E5 → 7ED - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 168 to 183 of the reply, 16 bits. The value is signed.
0x0000 = 0 → (0 ÷ 100) = 0 A
- Formula
(val ÷ 100)- Range
- -327.68 to 327.67 A
- Unit
- A
Confirmed for 2023. In testing for 2022, 2024 to 2026.
On-board charger, DC voltage GV60_OBC_DC_VOLTAGEConfirmed
- Request
22 E0 02 - Service 22
DID E002 - Module
7E5 → 7ED - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 152 to 167 of the reply, 16 bits.
0x1B1E = 6942 → (6942 ÷ 10) = 694.2 V
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
On-board charger, discharging AC current GV60_OBC_DCHRG_AC_CURRENTConfirmed
- Request
22 E0 01 - Service 22
DID E001 - Module
744 → 74C - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 216 to 223 of the reply, 8 bits.
0x00 = 0 → 0 A
- Formula
val- Range
- 0 to 255 A
- Unit
- A
Confirmed for 2023. In testing for 2022, 2024 to 2026.
On-board charger, discharging DC current GV60_OBC_DCHRG_DC_CURRENTConfirmed
- Request
22 E0 01 - Service 22
DID E001 - Module
744 → 74C - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 208 to 215 of the reply, 8 bits.
0x32 = 50 → 50 A
- Formula
val- Range
- 0 to 255 A
- Unit
- A
Confirmed for 2023. In testing for 2022, 2024 to 2026.
On-board charger, temperature a GV60_OBC_T_AConfirmed
- Request
22 E0 02 - Service 22
DID E002 - Module
7E5 → 7ED - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 216 to 223 of the reply, 8 bits.
0x42 = 66 → (66 − 40) = 26 °C
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2023. In testing for 2022, 2024 to 2026.
On-board charger, temperature b GV60_OBC_T_BConfirmed
- Request
22 E0 02 - Service 22
DID E002 - Module
7E5 → 7ED - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 224 to 231 of the reply, 8 bits.
0x42 = 66 → (66 − 40) = 26 °C
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery › Modules › 001
HV battery module 001 voltage GV60_HVBAT_CMU001_VOLTConfirmed
- Request
22 01 02 - Service 22
DID 0102 - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 32 to 39 of the reply, 8 bits.
0xB5 = 181 → (181 ÷ 50) = 3.62 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery › Modules › 002
HV battery module 002 voltage GV60_HVBAT_CMU002_VOLTConfirmed
- Request
22 01 02 - Service 22
DID 0102 - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 40 to 47 of the reply, 8 bits.
0xB5 = 181 → (181 ÷ 50) = 3.62 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery › Modules › 003
HV battery module 003 voltage GV60_HVBAT_CMU003_VOLTConfirmed
- Request
22 01 02 - Service 22
DID 0102 - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 48 to 55 of the reply, 8 bits.
0xB5 = 181 → (181 ÷ 50) = 3.62 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery › Modules › 004
HV battery module 004 voltage GV60_HVBAT_CMU004_VOLTConfirmed
- Request
22 01 02 - Service 22
DID 0102 - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 56 to 63 of the reply, 8 bits.
0xB5 = 181 → (181 ÷ 50) = 3.62 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery › Modules › 005
HV battery module 005 voltage GV60_HVBAT_CMU005_VOLTConfirmed
- Request
22 01 02 - Service 22
DID 0102 - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 64 to 71 of the reply, 8 bits.
0xB5 = 181 → (181 ÷ 50) = 3.62 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery › Modules › 006
HV battery module 006 voltage GV60_HVBAT_CMU006_VOLTConfirmed
- Request
22 01 02 - Service 22
DID 0102 - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 72 to 79 of the reply, 8 bits.
0xB5 = 181 → (181 ÷ 50) = 3.62 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery › Modules › 007
HV battery module 007 voltage GV60_HVBAT_CMU007_VOLTConfirmed
- Request
22 01 02 - Service 22
DID 0102 - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 80 to 87 of the reply, 8 bits.
0xB5 = 181 → (181 ÷ 50) = 3.62 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery › Modules › 008
HV battery module 008 voltage GV60_HVBAT_CMU008_VOLTConfirmed
- Request
22 01 02 - Service 22
DID 0102 - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 88 to 95 of the reply, 8 bits.
0xB5 = 181 → (181 ÷ 50) = 3.62 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery › Modules › 009
HV battery module 009 voltage GV60_HVBAT_CMU009_VOLTConfirmed
- Request
22 01 02 - Service 22
DID 0102 - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 96 to 103 of the reply, 8 bits.
0xB5 = 181 → (181 ÷ 50) = 3.62 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery › Modules › 010
HV battery module 010 voltage GV60_HVBAT_CMU010_VOLTConfirmed
- Request
22 01 02 - Service 22
DID 0102 - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 104 to 111 of the reply, 8 bits.
0xB5 = 181 → (181 ÷ 50) = 3.62 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery › Modules › 011
HV battery module 011 voltage GV60_HVBAT_CMU011_VOLTConfirmed
- Request
22 01 02 - Service 22
DID 0102 - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 112 to 119 of the reply, 8 bits.
0xB5 = 181 → (181 ÷ 50) = 3.62 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery › Modules › 012
HV battery module 012 voltage GV60_HVBAT_CMU012_VOLTConfirmed
- Request
22 01 02 - Service 22
DID 0102 - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 120 to 127 of the reply, 8 bits.
0xB5 = 181 → (181 ÷ 50) = 3.62 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery › Modules › 013
HV battery module 013 voltage GV60_HVBAT_CMU013_VOLTConfirmed
- Request
22 01 02 - Service 22
DID 0102 - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 128 to 135 of the reply, 8 bits.
0xB5 = 181 → (181 ÷ 50) = 3.62 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery › Modules › 014
HV battery module 014 voltage GV60_HVBAT_CMU014_VOLTConfirmed
- Request
22 01 02 - Service 22
DID 0102 - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 136 to 143 of the reply, 8 bits.
0xB5 = 181 → (181 ÷ 50) = 3.62 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery › Modules › 015
HV battery module 015 voltage GV60_HVBAT_CMU015_VOLTConfirmed
- Request
22 01 02 - Service 22
DID 0102 - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 144 to 151 of the reply, 8 bits.
0xB5 = 181 → (181 ÷ 50) = 3.62 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery › Modules › 016
HV battery module 016 voltage GV60_HVBAT_CMU016_VOLTConfirmed
- Request
22 01 02 - Service 22
DID 0102 - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 152 to 159 of the reply, 8 bits.
0xB5 = 181 → (181 ÷ 50) = 3.62 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery › Modules › 017
HV battery module 017 voltage GV60_HVBAT_CMU017_VOLTConfirmed
- Request
22 01 02 - Service 22
DID 0102 - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 160 to 167 of the reply, 8 bits.
0xB5 = 181 → (181 ÷ 50) = 3.62 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery › Modules › 018
HV battery module 018 voltage GV60_HVBAT_CMU018_VOLTConfirmed
- Request
22 01 02 - Service 22
DID 0102 - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 168 to 175 of the reply, 8 bits.
0xB5 = 181 → (181 ÷ 50) = 3.62 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery › Modules › 019
HV battery module 019 voltage GV60_HVBAT_CMU019_VOLTConfirmed
- Request
22 01 02 - Service 22
DID 0102 - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 176 to 183 of the reply, 8 bits.
0xB5 = 181 → (181 ÷ 50) = 3.62 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery › Modules › 020
HV battery module 020 voltage GV60_HVBAT_CMU020_VOLTConfirmed
- Request
22 01 02 - Service 22
DID 0102 - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 184 to 191 of the reply, 8 bits.
0xB5 = 181 → (181 ÷ 50) = 3.62 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery › Modules › 021
HV battery module 021 voltage GV60_HVBAT_CMU021_VOLTConfirmed
- Request
22 01 02 - Service 22
DID 0102 - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 192 to 199 of the reply, 8 bits.
0xB5 = 181 → (181 ÷ 50) = 3.62 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery › Modules › 022
HV battery module 022 voltage GV60_HVBAT_CMU022_VOLTConfirmed
- Request
22 01 02 - Service 22
DID 0102 - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 200 to 207 of the reply, 8 bits.
0xB5 = 181 → (181 ÷ 50) = 3.62 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery › Modules › 023
HV battery module 023 voltage GV60_HVBAT_CMU023_VOLTConfirmed
- Request
22 01 02 - Service 22
DID 0102 - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 208 to 215 of the reply, 8 bits.
0xB5 = 181 → (181 ÷ 50) = 3.62 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery › Modules › 024
HV battery module 024 voltage GV60_HVBAT_CMU024_VOLTConfirmed
- Request
22 01 02 - Service 22
DID 0102 - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 216 to 223 of the reply, 8 bits.
0xB5 = 181 → (181 ÷ 50) = 3.62 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery › Modules › 025
HV battery module 025 voltage GV60_HVBAT_CMU025_VOLTConfirmed
- Request
22 01 02 - Service 22
DID 0102 - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 224 to 231 of the reply, 8 bits.
0xB5 = 181 → (181 ÷ 50) = 3.62 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery › Modules › 026
HV battery module 026 voltage GV60_HVBAT_CMU026_VOLTConfirmed
- Request
22 01 02 - Service 22
DID 0102 - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 232 to 239 of the reply, 8 bits.
0xB5 = 181 → (181 ÷ 50) = 3.62 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery › Modules › 027
HV battery module 027 voltage GV60_HVBAT_CMU027_VOLTConfirmed
- Request
22 01 02 - Service 22
DID 0102 - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 240 to 247 of the reply, 8 bits.
0xB5 = 181 → (181 ÷ 50) = 3.62 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery › Modules › 028
HV battery module 028 voltage GV60_HVBAT_CMU028_VOLTConfirmed
- Request
22 01 02 - Service 22
DID 0102 - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 248 to 255 of the reply, 8 bits.
0xB5 = 181 → (181 ÷ 50) = 3.62 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery › Modules › 029
HV battery module 029 voltage GV60_HVBAT_CMU029_VOLTConfirmed
- Request
22 01 02 - Service 22
DID 0102 - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 256 to 263 of the reply, 8 bits.
0xB5 = 181 → (181 ÷ 50) = 3.62 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery › Modules › 030
HV battery module 030 voltage GV60_HVBAT_CMU030_VOLTConfirmed
- Request
22 01 02 - Service 22
DID 0102 - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 264 to 271 of the reply, 8 bits.
0xB5 = 181 → (181 ÷ 50) = 3.62 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery › Modules › 031
HV battery module 031 voltage GV60_HVBAT_CMU031_VOLTConfirmed
- Request
22 01 02 - Service 22
DID 0102 - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 272 to 279 of the reply, 8 bits.
0xB5 = 181 → (181 ÷ 50) = 3.62 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery › Modules › 032
HV battery module 032 voltage GV60_HVBAT_CMU032_VOLTConfirmed
- Request
22 01 02 - Service 22
DID 0102 - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 280 to 287 of the reply, 8 bits.
0xB5 = 181 → (181 ÷ 50) = 3.62 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery › Modules › 033
HV battery module 033 voltage GV60_HVBAT_CMU033_VOLTConfirmed
- Request
22 01 03 - Service 22
DID 0103 - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 32 to 39 of the reply, 8 bits.
0xB5 = 181 → (181 ÷ 50) = 3.62 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery › Modules › 034
HV battery module 034 voltage GV60_HVBAT_CMU034_VOLTConfirmed
- Request
22 01 03 - Service 22
DID 0103 - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 40 to 47 of the reply, 8 bits.
0xB5 = 181 → (181 ÷ 50) = 3.62 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery › Modules › 035
HV battery module 035 voltage GV60_HVBAT_CMU035_VOLTConfirmed
- Request
22 01 03 - Service 22
DID 0103 - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 48 to 55 of the reply, 8 bits.
0xB5 = 181 → (181 ÷ 50) = 3.62 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery › Modules › 036
HV battery module 036 voltage GV60_HVBAT_CMU036_VOLTConfirmed
- Request
22 01 03 - Service 22
DID 0103 - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 56 to 63 of the reply, 8 bits.
0xB5 = 181 → (181 ÷ 50) = 3.62 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery › Modules › 037
HV battery module 037 voltage GV60_HVBAT_CMU037_VOLTConfirmed
- Request
22 01 03 - Service 22
DID 0103 - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 64 to 71 of the reply, 8 bits.
0xB5 = 181 → (181 ÷ 50) = 3.62 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery › Modules › 038
HV battery module 038 voltage GV60_HVBAT_CMU038_VOLTConfirmed
- Request
22 01 03 - Service 22
DID 0103 - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 72 to 79 of the reply, 8 bits.
0xB5 = 181 → (181 ÷ 50) = 3.62 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery › Modules › 039
HV battery module 039 voltage GV60_HVBAT_CMU039_VOLTConfirmed
- Request
22 01 03 - Service 22
DID 0103 - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 80 to 87 of the reply, 8 bits.
0xB5 = 181 → (181 ÷ 50) = 3.62 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery › Modules › 040
HV battery module 040 voltage GV60_HVBAT_CMU040_VOLTConfirmed
- Request
22 01 03 - Service 22
DID 0103 - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 88 to 95 of the reply, 8 bits.
0xB5 = 181 → (181 ÷ 50) = 3.62 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery › Modules › 041
HV battery module 041 voltage GV60_HVBAT_CMU041_VOLTConfirmed
- Request
22 01 03 - Service 22
DID 0103 - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 96 to 103 of the reply, 8 bits.
0xB5 = 181 → (181 ÷ 50) = 3.62 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery › Modules › 042
HV battery module 042 voltage GV60_HVBAT_CMU042_VOLTConfirmed
- Request
22 01 03 - Service 22
DID 0103 - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 104 to 111 of the reply, 8 bits.
0xB5 = 181 → (181 ÷ 50) = 3.62 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery › Modules › 043
HV battery module 043 voltage GV60_HVBAT_CMU043_VOLTConfirmed
- Request
22 01 03 - Service 22
DID 0103 - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 112 to 119 of the reply, 8 bits.
0xB5 = 181 → (181 ÷ 50) = 3.62 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery › Modules › 044
HV battery module 044 voltage GV60_HVBAT_CMU044_VOLTConfirmed
- Request
22 01 03 - Service 22
DID 0103 - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 120 to 127 of the reply, 8 bits.
0xB5 = 181 → (181 ÷ 50) = 3.62 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery › Modules › 045
HV battery module 045 voltage GV60_HVBAT_CMU045_VOLTConfirmed
- Request
22 01 03 - Service 22
DID 0103 - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 128 to 135 of the reply, 8 bits.
0xB5 = 181 → (181 ÷ 50) = 3.62 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery › Modules › 046
HV battery module 046 voltage GV60_HVBAT_CMU046_VOLTConfirmed
- Request
22 01 03 - Service 22
DID 0103 - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 136 to 143 of the reply, 8 bits.
0xB5 = 181 → (181 ÷ 50) = 3.62 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery › Modules › 047
HV battery module 047 voltage GV60_HVBAT_CMU047_VOLTConfirmed
- Request
22 01 03 - Service 22
DID 0103 - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 144 to 151 of the reply, 8 bits.
0xB5 = 181 → (181 ÷ 50) = 3.62 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery › Modules › 048
HV battery module 048 voltage GV60_HVBAT_CMU048_VOLTConfirmed
- Request
22 01 03 - Service 22
DID 0103 - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 152 to 159 of the reply, 8 bits.
0xB5 = 181 → (181 ÷ 50) = 3.62 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery › Modules › 049
HV battery module 049 voltage GV60_HVBAT_CMU049_VOLTConfirmed
- Request
22 01 03 - Service 22
DID 0103 - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 160 to 167 of the reply, 8 bits.
0xB5 = 181 → (181 ÷ 50) = 3.62 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery › Modules › 050
HV battery module 050 voltage GV60_HVBAT_CMU050_VOLTConfirmed
- Request
22 01 03 - Service 22
DID 0103 - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 168 to 175 of the reply, 8 bits.
0xB5 = 181 → (181 ÷ 50) = 3.62 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery › Modules › 051
HV battery module 051 voltage GV60_HVBAT_CMU051_VOLTConfirmed
- Request
22 01 03 - Service 22
DID 0103 - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 176 to 183 of the reply, 8 bits.
0xB5 = 181 → (181 ÷ 50) = 3.62 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery › Modules › 052
HV battery module 052 voltage GV60_HVBAT_CMU052_VOLTConfirmed
- Request
22 01 03 - Service 22
DID 0103 - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 184 to 191 of the reply, 8 bits.
0xB5 = 181 → (181 ÷ 50) = 3.62 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery › Modules › 053
HV battery module 053 voltage GV60_HVBAT_CMU053_VOLTConfirmed
- Request
22 01 03 - Service 22
DID 0103 - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 192 to 199 of the reply, 8 bits.
0xB5 = 181 → (181 ÷ 50) = 3.62 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery › Modules › 054
HV battery module 054 voltage GV60_HVBAT_CMU054_VOLTConfirmed
- Request
22 01 03 - Service 22
DID 0103 - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 200 to 207 of the reply, 8 bits.
0xB5 = 181 → (181 ÷ 50) = 3.62 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery › Modules › 055
HV battery module 055 voltage GV60_HVBAT_CMU055_VOLTConfirmed
- Request
22 01 03 - Service 22
DID 0103 - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 208 to 215 of the reply, 8 bits.
0xB5 = 181 → (181 ÷ 50) = 3.62 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery › Modules › 056
HV battery module 056 voltage GV60_HVBAT_CMU056_VOLTConfirmed
- Request
22 01 03 - Service 22
DID 0103 - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 216 to 223 of the reply, 8 bits.
0xB5 = 181 → (181 ÷ 50) = 3.62 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery › Modules › 057
HV battery module 057 voltage GV60_HVBAT_CMU057_VOLTConfirmed
- Request
22 01 03 - Service 22
DID 0103 - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 224 to 231 of the reply, 8 bits.
0xB5 = 181 → (181 ÷ 50) = 3.62 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery › Modules › 058
HV battery module 058 voltage GV60_HVBAT_CMU058_VOLTConfirmed
- Request
22 01 03 - Service 22
DID 0103 - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 232 to 239 of the reply, 8 bits.
0xB5 = 181 → (181 ÷ 50) = 3.62 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery › Modules › 059
HV battery module 059 voltage GV60_HVBAT_CMU059_VOLTConfirmed
- Request
22 01 03 - Service 22
DID 0103 - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 240 to 247 of the reply, 8 bits.
0xB5 = 181 → (181 ÷ 50) = 3.62 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery › Modules › 060
HV battery module 060 voltage GV60_HVBAT_CMU060_VOLTConfirmed
- Request
22 01 03 - Service 22
DID 0103 - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 248 to 255 of the reply, 8 bits.
0xB5 = 181 → (181 ÷ 50) = 3.62 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery › Modules › 061
HV battery module 061 voltage GV60_HVBAT_CMU061_VOLTConfirmed
- Request
22 01 03 - Service 22
DID 0103 - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 256 to 263 of the reply, 8 bits.
0xB5 = 181 → (181 ÷ 50) = 3.62 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery › Modules › 062
HV battery module 062 voltage GV60_HVBAT_CMU062_VOLTConfirmed
- Request
22 01 03 - Service 22
DID 0103 - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 264 to 271 of the reply, 8 bits.
0xB5 = 181 → (181 ÷ 50) = 3.62 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery › Modules › 063
HV battery module 063 voltage GV60_HVBAT_CMU063_VOLTConfirmed
- Request
22 01 03 - Service 22
DID 0103 - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 272 to 279 of the reply, 8 bits.
0xB5 = 181 → (181 ÷ 50) = 3.62 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery › Modules › 064
HV battery module 064 voltage GV60_HVBAT_CMU064_VOLTConfirmed
- Request
22 01 03 - Service 22
DID 0103 - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 280 to 287 of the reply, 8 bits.
0xB5 = 181 → (181 ÷ 50) = 3.62 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery › Modules › 065
HV battery module 065 voltage GV60_HVBAT_CMU065_VOLTConfirmed
- Request
22 01 04 - Service 22
DID 0104 - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 32 to 39 of the reply, 8 bits.
0xBB = 187 → (187 ÷ 50) = 3.74 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery › Modules › 066
HV battery module 066 voltage GV60_HVBAT_CMU066_VOLTConfirmed
- Request
22 01 04 - Service 22
DID 0104 - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 40 to 47 of the reply, 8 bits.
0xBB = 187 → (187 ÷ 50) = 3.74 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery › Modules › 067
HV battery module 067 voltage GV60_HVBAT_CMU067_VOLTConfirmed
- Request
22 01 04 - Service 22
DID 0104 - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 48 to 55 of the reply, 8 bits.
0xBB = 187 → (187 ÷ 50) = 3.74 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery › Modules › 068
HV battery module 068 voltage GV60_HVBAT_CMU068_VOLTConfirmed
- Request
22 01 04 - Service 22
DID 0104 - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 56 to 63 of the reply, 8 bits.
0xBB = 187 → (187 ÷ 50) = 3.74 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery › Modules › 069
HV battery module 069 voltage GV60_HVBAT_CMU069_VOLTConfirmed
- Request
22 01 04 - Service 22
DID 0104 - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 64 to 71 of the reply, 8 bits.
0xBB = 187 → (187 ÷ 50) = 3.74 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery › Modules › 070
HV battery module 070 voltage GV60_HVBAT_CMU070_VOLTConfirmed
- Request
22 01 04 - Service 22
DID 0104 - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 72 to 79 of the reply, 8 bits.
0xBB = 187 → (187 ÷ 50) = 3.74 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery › Modules › 071
HV battery module 071 voltage GV60_HVBAT_CMU071_VOLTConfirmed
- Request
22 01 04 - Service 22
DID 0104 - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 80 to 87 of the reply, 8 bits.
0xBB = 187 → (187 ÷ 50) = 3.74 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery › Modules › 072
HV battery module 072 voltage GV60_HVBAT_CMU072_VOLTConfirmed
- Request
22 01 04 - Service 22
DID 0104 - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 88 to 95 of the reply, 8 bits.
0xBA = 186 → (186 ÷ 50) = 3.72 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery › Modules › 073
HV battery module 073 voltage GV60_HVBAT_CMU073_VOLTConfirmed
- Request
22 01 04 - Service 22
DID 0104 - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 96 to 103 of the reply, 8 bits.
0xBA = 186 → (186 ÷ 50) = 3.72 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery › Modules › 074
HV battery module 074 voltage GV60_HVBAT_CMU074_VOLTConfirmed
- Request
22 01 04 - Service 22
DID 0104 - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 104 to 111 of the reply, 8 bits.
0xBA = 186 → (186 ÷ 50) = 3.72 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery › Modules › 075
HV battery module 075 voltage GV60_HVBAT_CMU075_VOLTConfirmed
- Request
22 01 04 - Service 22
DID 0104 - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 112 to 119 of the reply, 8 bits.
0xBA = 186 → (186 ÷ 50) = 3.72 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery › Modules › 076
HV battery module 076 voltage GV60_HVBAT_CMU076_VOLTConfirmed
- Request
22 01 04 - Service 22
DID 0104 - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 120 to 127 of the reply, 8 bits.
0xBA = 186 → (186 ÷ 50) = 3.72 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery › Modules › 077
HV battery module 077 voltage GV60_HVBAT_CMU077_VOLTConfirmed
- Request
22 01 04 - Service 22
DID 0104 - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 128 to 135 of the reply, 8 bits.
0xBB = 187 → (187 ÷ 50) = 3.74 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery › Modules › 078
HV battery module 078 voltage GV60_HVBAT_CMU078_VOLTConfirmed
- Request
22 01 04 - Service 22
DID 0104 - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 136 to 143 of the reply, 8 bits.
0xBB = 187 → (187 ÷ 50) = 3.74 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery › Modules › 079
HV battery module 079 voltage GV60_HVBAT_CMU079_VOLTConfirmed
- Request
22 01 04 - Service 22
DID 0104 - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 144 to 151 of the reply, 8 bits.
0xBA = 186 → (186 ÷ 50) = 3.72 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery › Modules › 080
HV battery module 080 voltage GV60_HVBAT_CMU080_VOLTConfirmed
- Request
22 01 04 - Service 22
DID 0104 - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 152 to 159 of the reply, 8 bits.
0xBA = 186 → (186 ÷ 50) = 3.72 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery › Modules › 081
HV battery module 081 voltage GV60_HVBAT_CMU081_VOLTConfirmed
- Request
22 01 04 - Service 22
DID 0104 - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 160 to 167 of the reply, 8 bits.
0xBA = 186 → (186 ÷ 50) = 3.72 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery › Modules › 082
HV battery module 082 voltage GV60_HVBAT_CMU082_VOLTConfirmed
- Request
22 01 04 - Service 22
DID 0104 - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 168 to 175 of the reply, 8 bits.
0xBA = 186 → (186 ÷ 50) = 3.72 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery › Modules › 083
HV battery module 083 voltage GV60_HVBAT_CMU083_VOLTConfirmed
- Request
22 01 04 - Service 22
DID 0104 - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 176 to 183 of the reply, 8 bits.
0xBA = 186 → (186 ÷ 50) = 3.72 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery › Modules › 084
HV battery module 084 voltage GV60_HVBAT_CMU084_VOLTConfirmed
- Request
22 01 04 - Service 22
DID 0104 - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 184 to 191 of the reply, 8 bits.
0xBA = 186 → (186 ÷ 50) = 3.72 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery › Modules › 085
HV battery module 085 voltage GV60_HVBAT_CMU085_VOLTConfirmed
- Request
22 01 04 - Service 22
DID 0104 - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 192 to 199 of the reply, 8 bits.
0xBB = 187 → (187 ÷ 50) = 3.74 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery › Modules › 086
HV battery module 086 voltage GV60_HVBAT_CMU086_VOLTConfirmed
- Request
22 01 04 - Service 22
DID 0104 - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 200 to 207 of the reply, 8 bits.
0xBB = 187 → (187 ÷ 50) = 3.74 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery › Modules › 087
HV battery module 087 voltage GV60_HVBAT_CMU087_VOLTConfirmed
- Request
22 01 04 - Service 22
DID 0104 - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 208 to 215 of the reply, 8 bits.
0xBA = 186 → (186 ÷ 50) = 3.72 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery › Modules › 088
HV battery module 088 voltage GV60_HVBAT_CMU088_VOLTConfirmed
- Request
22 01 04 - Service 22
DID 0104 - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 216 to 223 of the reply, 8 bits.
0xBB = 187 → (187 ÷ 50) = 3.74 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery › Modules › 089
HV battery module 089 voltage GV60_HVBAT_CMU089_VOLTConfirmed
- Request
22 01 04 - Service 22
DID 0104 - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 224 to 231 of the reply, 8 bits.
0xBA = 186 → (186 ÷ 50) = 3.72 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery › Modules › 090
HV battery module 090 voltage GV60_HVBAT_CMU090_VOLTConfirmed
- Request
22 01 04 - Service 22
DID 0104 - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 232 to 239 of the reply, 8 bits.
0xBB = 187 → (187 ÷ 50) = 3.74 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery › Modules › 091
HV battery module 091 voltage GV60_HVBAT_CMU091_VOLTConfirmed
- Request
22 01 04 - Service 22
DID 0104 - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 240 to 247 of the reply, 8 bits.
0xBA = 186 → (186 ÷ 50) = 3.72 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery › Modules › 092
HV battery module 092 voltage GV60_HVBAT_CMU092_VOLTConfirmed
- Request
22 01 04 - Service 22
DID 0104 - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 248 to 255 of the reply, 8 bits.
0xBA = 186 → (186 ÷ 50) = 3.72 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery › Modules › 093
HV battery module 093 voltage GV60_HVBAT_CMU093_VOLTConfirmed
- Request
22 01 04 - Service 22
DID 0104 - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 256 to 263 of the reply, 8 bits.
0xBA = 186 → (186 ÷ 50) = 3.72 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery › Modules › 094
HV battery module 094 voltage GV60_HVBAT_CMU094_VOLTConfirmed
- Request
22 01 04 - Service 22
DID 0104 - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 264 to 271 of the reply, 8 bits.
0xBA = 186 → (186 ÷ 50) = 3.72 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery › Modules › 095
HV battery module 095 voltage GV60_HVBAT_CMU095_VOLTConfirmed
- Request
22 01 04 - Service 22
DID 0104 - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 272 to 279 of the reply, 8 bits.
0xBA = 186 → (186 ÷ 50) = 3.72 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery › Modules › 096
HV battery module 096 voltage GV60_HVBAT_CMU096_VOLTConfirmed
- Request
22 01 04 - Service 22
DID 0104 - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 280 to 287 of the reply, 8 bits.
0xBB = 187 → (187 ÷ 50) = 3.74 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery › Modules › 097
HV battery module 097 voltage GV60_HVBAT_CMU097_VOLTConfirmed
- Request
22 01 0A - Service 22
DID 010A - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 32 to 39 of the reply, 8 bits.
0xBA = 186 → (186 ÷ 50) = 3.72 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery › Modules › 098
HV battery module 098 voltage GV60_HVBAT_CMU098_VOLTConfirmed
- Request
22 01 0A - Service 22
DID 010A - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 40 to 47 of the reply, 8 bits.
0xBA = 186 → (186 ÷ 50) = 3.72 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery › Modules › 099
HV battery module 099 voltage GV60_HVBAT_CMU099_VOLTConfirmed
- Request
22 01 0A - Service 22
DID 010A - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 48 to 55 of the reply, 8 bits.
0xBB = 187 → (187 ÷ 50) = 3.74 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery › Modules › 100
HV battery module 100 voltage GV60_HVBAT_CMU100_VOLTConfirmed
- Request
22 01 0A - Service 22
DID 010A - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 56 to 63 of the reply, 8 bits.
0xBB = 187 → (187 ÷ 50) = 3.74 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery › Modules › 101
HV battery module 101 voltage GV60_HVBAT_CMU101_VOLTConfirmed
- Request
22 01 0A - Service 22
DID 010A - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 64 to 71 of the reply, 8 bits.
0xBB = 187 → (187 ÷ 50) = 3.74 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery › Modules › 102
HV battery module 102 voltage GV60_HVBAT_CMU102_VOLTConfirmed
- Request
22 01 0A - Service 22
DID 010A - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 72 to 79 of the reply, 8 bits.
0xBB = 187 → (187 ÷ 50) = 3.74 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery › Modules › 103
HV battery module 103 voltage GV60_HVBAT_CMU103_VOLTConfirmed
- Request
22 01 0A - Service 22
DID 010A - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 80 to 87 of the reply, 8 bits.
0xBB = 187 → (187 ÷ 50) = 3.74 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery › Modules › 104
HV battery module 104 voltage GV60_HVBAT_CMU104_VOLTConfirmed
- Request
22 01 0A - Service 22
DID 010A - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 88 to 95 of the reply, 8 bits.
0xBB = 187 → (187 ÷ 50) = 3.74 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery › Modules › 105
HV battery module 105 voltage GV60_HVBAT_CMU105_VOLTConfirmed
- Request
22 01 0A - Service 22
DID 010A - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 96 to 103 of the reply, 8 bits.
0xBB = 187 → (187 ÷ 50) = 3.74 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery › Modules › 106
HV battery module 106 voltage GV60_HVBAT_CMU106_VOLTConfirmed
- Request
22 01 0A - Service 22
DID 010A - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 104 to 111 of the reply, 8 bits.
0xBB = 187 → (187 ÷ 50) = 3.74 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery › Modules › 107
HV battery module 107 voltage GV60_HVBAT_CMU107_VOLTConfirmed
- Request
22 01 0A - Service 22
DID 010A - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 112 to 119 of the reply, 8 bits.
0xBB = 187 → (187 ÷ 50) = 3.74 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery › Modules › 108
HV battery module 108 voltage GV60_HVBAT_CMU108_VOLTConfirmed
- Request
22 01 0A - Service 22
DID 010A - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 120 to 127 of the reply, 8 bits.
0xBB = 187 → (187 ÷ 50) = 3.74 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery › Modules › 109
HV battery module 109 voltage GV60_HVBAT_CMU109_VOLTConfirmed
- Request
22 01 0A - Service 22
DID 010A - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 128 to 135 of the reply, 8 bits.
0xBB = 187 → (187 ÷ 50) = 3.74 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery › Modules › 110
HV battery module 110 voltage GV60_HVBAT_CMU110_VOLTConfirmed
- Request
22 01 0A - Service 22
DID 010A - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 136 to 143 of the reply, 8 bits.
0xBB = 187 → (187 ÷ 50) = 3.74 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery › Modules › 111
HV battery module 111 voltage GV60_HVBAT_CMU111_VOLTConfirmed
- Request
22 01 0A - Service 22
DID 010A - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 144 to 151 of the reply, 8 bits.
0xBC = 188 → (188 ÷ 50) = 3.76 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery › Modules › 112
HV battery module 112 voltage GV60_HVBAT_CMU112_VOLTConfirmed
- Request
22 01 0A - Service 22
DID 010A - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 152 to 159 of the reply, 8 bits.
0xBB = 187 → (187 ÷ 50) = 3.74 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery › Modules › 113
HV battery module 113 voltage GV60_HVBAT_CMU113_VOLTConfirmed
- Request
22 01 0A - Service 22
DID 010A - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 160 to 167 of the reply, 8 bits.
0xBC = 188 → (188 ÷ 50) = 3.76 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery › Modules › 114
HV battery module 114 voltage GV60_HVBAT_CMU114_VOLTConfirmed
- Request
22 01 0A - Service 22
DID 010A - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 168 to 175 of the reply, 8 bits.
0xBC = 188 → (188 ÷ 50) = 3.76 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery › Modules › 115
HV battery module 115 voltage GV60_HVBAT_CMU115_VOLTConfirmed
- Request
22 01 0A - Service 22
DID 010A - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 176 to 183 of the reply, 8 bits.
0xBB = 187 → (187 ÷ 50) = 3.74 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery › Modules › 116
HV battery module 116 voltage GV60_HVBAT_CMU116_VOLTConfirmed
- Request
22 01 0A - Service 22
DID 010A - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 184 to 191 of the reply, 8 bits.
0xBB = 187 → (187 ÷ 50) = 3.74 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery › Modules › 117
HV battery module 117 voltage GV60_HVBAT_CMU117_VOLTConfirmed
- Request
22 01 0A - Service 22
DID 010A - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 192 to 199 of the reply, 8 bits.
0xBB = 187 → (187 ÷ 50) = 3.74 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery › Modules › 118
HV battery module 118 voltage GV60_HVBAT_CMU118_VOLTConfirmed
- Request
22 01 0A - Service 22
DID 010A - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 200 to 207 of the reply, 8 bits.
0xBB = 187 → (187 ÷ 50) = 3.74 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery › Modules › 119
HV battery module 119 voltage GV60_HVBAT_CMU119_VOLTConfirmed
- Request
22 01 0A - Service 22
DID 010A - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 208 to 215 of the reply, 8 bits.
0xBB = 187 → (187 ÷ 50) = 3.74 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery › Modules › 120
HV battery module 120 voltage GV60_HVBAT_CMU120_VOLTConfirmed
- Request
22 01 0A - Service 22
DID 010A - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 216 to 223 of the reply, 8 bits.
0xBB = 187 → (187 ÷ 50) = 3.74 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery › Modules › 121
HV battery module 121 voltage GV60_HVBAT_CMU121_VOLTConfirmed
- Request
22 01 0A - Service 22
DID 010A - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 224 to 231 of the reply, 8 bits.
0xBB = 187 → (187 ÷ 50) = 3.74 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery › Modules › 122
HV battery module 122 voltage GV60_HVBAT_CMU122_VOLTConfirmed
- Request
22 01 0A - Service 22
DID 010A - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 232 to 239 of the reply, 8 bits.
0xBB = 187 → (187 ÷ 50) = 3.74 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery › Modules › 123
HV battery module 123 voltage GV60_HVBAT_CMU123_VOLTConfirmed
- Request
22 01 0A - Service 22
DID 010A - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 240 to 247 of the reply, 8 bits.
0xBB = 187 → (187 ÷ 50) = 3.74 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery › Modules › 124
HV battery module 124 voltage GV60_HVBAT_CMU124_VOLTConfirmed
- Request
22 01 0A - Service 22
DID 010A - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 248 to 255 of the reply, 8 bits.
0xBB = 187 → (187 ÷ 50) = 3.74 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery › Modules › 125
HV battery module 125 voltage GV60_HVBAT_CMU125_VOLTConfirmed
- Request
22 01 0A - Service 22
DID 010A - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 256 to 263 of the reply, 8 bits.
0xBB = 187 → (187 ÷ 50) = 3.74 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery › Modules › 126
HV battery module 126 voltage GV60_HVBAT_CMU126_VOLTConfirmed
- Request
22 01 0A - Service 22
DID 010A - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 264 to 271 of the reply, 8 bits.
0xBB = 187 → (187 ÷ 50) = 3.74 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery › Modules › 127
HV battery module 127 voltage GV60_HVBAT_CMU127_VOLTConfirmed
- Request
22 01 0A - Service 22
DID 010A - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 272 to 279 of the reply, 8 bits.
0xBB = 187 → (187 ÷ 50) = 3.74 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery › Modules › 128
HV battery module 128 voltage GV60_HVBAT_CMU128_VOLTConfirmed
- Request
22 01 0A - Service 22
DID 010A - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 280 to 287 of the reply, 8 bits.
0xBB = 187 → (187 ÷ 50) = 3.74 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery › Modules › 129
HV battery module 129 voltage GV60_HVBAT_CMU129_VOLTConfirmed
- Request
22 01 0B - Service 22
DID 010B - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 32 to 39 of the reply, 8 bits.
0xBB = 187 → (187 ÷ 50) = 3.74 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery › Modules › 130
HV battery module 130 voltage GV60_HVBAT_CMU130_VOLTConfirmed
- Request
22 01 0B - Service 22
DID 010B - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 40 to 47 of the reply, 8 bits.
0xBB = 187 → (187 ÷ 50) = 3.74 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery › Modules › 131
HV battery module 131 voltage GV60_HVBAT_CMU131_VOLTConfirmed
- Request
22 01 0B - Service 22
DID 010B - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 48 to 55 of the reply, 8 bits.
0xBB = 187 → (187 ÷ 50) = 3.74 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery › Modules › 132
HV battery module 132 voltage GV60_HVBAT_CMU132_VOLTConfirmed
- Request
22 01 0B - Service 22
DID 010B - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 56 to 63 of the reply, 8 bits.
0xBB = 187 → (187 ÷ 50) = 3.74 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery › Modules › 133
HV battery module 133 voltage GV60_HVBAT_CMU133_VOLTConfirmed
- Request
22 01 0B - Service 22
DID 010B - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 64 to 71 of the reply, 8 bits.
0xBB = 187 → (187 ÷ 50) = 3.74 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery › Modules › 134
HV battery module 134 voltage GV60_HVBAT_CMU134_VOLTConfirmed
- Request
22 01 0B - Service 22
DID 010B - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 72 to 79 of the reply, 8 bits.
0xBB = 187 → (187 ÷ 50) = 3.74 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery › Modules › 135
HV battery module 135 voltage GV60_HVBAT_CMU135_VOLTConfirmed
- Request
22 01 0B - Service 22
DID 010B - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 80 to 87 of the reply, 8 bits.
0xBB = 187 → (187 ÷ 50) = 3.74 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery › Modules › 136
HV battery module 136 voltage GV60_HVBAT_CMU136_VOLTConfirmed
- Request
22 01 0B - Service 22
DID 010B - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 88 to 95 of the reply, 8 bits.
0xBB = 187 → (187 ÷ 50) = 3.74 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery › Modules › 137
HV battery module 137 voltage GV60_HVBAT_CMU137_VOLTConfirmed
- Request
22 01 0B - Service 22
DID 010B - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 96 to 103 of the reply, 8 bits.
0xBB = 187 → (187 ÷ 50) = 3.74 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery › Modules › 138
HV battery module 138 voltage GV60_HVBAT_CMU138_VOLTConfirmed
- Request
22 01 0B - Service 22
DID 010B - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 104 to 111 of the reply, 8 bits.
0xBC = 188 → (188 ÷ 50) = 3.76 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery › Modules › 139
HV battery module 139 voltage GV60_HVBAT_CMU139_VOLTConfirmed
- Request
22 01 0B - Service 22
DID 010B - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 112 to 119 of the reply, 8 bits.
0xBB = 187 → (187 ÷ 50) = 3.74 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery › Modules › 140
HV battery module 140 voltage GV60_HVBAT_CMU140_VOLTConfirmed
- Request
22 01 0B - Service 22
DID 010B - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 120 to 127 of the reply, 8 bits.
0xBA = 186 → (186 ÷ 50) = 3.72 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery › Modules › 141
HV battery module 141 voltage GV60_HVBAT_CMU141_VOLTConfirmed
- Request
22 01 0B - Service 22
DID 010B - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 128 to 135 of the reply, 8 bits.
0xBB = 187 → (187 ÷ 50) = 3.74 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery › Modules › 142
HV battery module 142 voltage GV60_HVBAT_CMU142_VOLTConfirmed
- Request
22 01 0B - Service 22
DID 010B - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 136 to 143 of the reply, 8 bits.
0xBB = 187 → (187 ÷ 50) = 3.74 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery › Modules › 143
HV battery module 143 voltage GV60_HVBAT_CMU143_VOLTConfirmed
- Request
22 01 0B - Service 22
DID 010B - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 144 to 151 of the reply, 8 bits.
0xBB = 187 → (187 ÷ 50) = 3.74 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery › Modules › 144
HV battery module 144 voltage GV60_HVBAT_CMU144_VOLTConfirmed
- Request
22 01 0B - Service 22
DID 010B - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 152 to 159 of the reply, 8 bits.
0xBB = 187 → (187 ÷ 50) = 3.74 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery › Modules › 145
HV battery module 145 voltage GV60_HVBAT_CMU145_VOLTConfirmed
- Request
22 01 0B - Service 22
DID 010B - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 160 to 167 of the reply, 8 bits.
0xBA = 186 → (186 ÷ 50) = 3.72 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery › Modules › 146
HV battery module 146 voltage GV60_HVBAT_CMU146_VOLTConfirmed
- Request
22 01 0B - Service 22
DID 010B - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 168 to 175 of the reply, 8 bits.
0xBA = 186 → (186 ÷ 50) = 3.72 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery › Modules › 147
HV battery module 147 voltage GV60_HVBAT_CMU147_VOLTConfirmed
- Request
22 01 0B - Service 22
DID 010B - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 176 to 183 of the reply, 8 bits.
0xBB = 187 → (187 ÷ 50) = 3.74 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery › Modules › 148
HV battery module 148 voltage GV60_HVBAT_CMU148_VOLTConfirmed
- Request
22 01 0B - Service 22
DID 010B - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 184 to 191 of the reply, 8 bits.
0xBA = 186 → (186 ÷ 50) = 3.72 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery › Modules › 149
HV battery module 149 voltage GV60_HVBAT_CMU149_VOLTConfirmed
- Request
22 01 0B - Service 22
DID 010B - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 192 to 199 of the reply, 8 bits.
0xBB = 187 → (187 ÷ 50) = 3.74 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery › Modules › 150
HV battery module 150 voltage GV60_HVBAT_CMU150_VOLTConfirmed
- Request
22 01 0B - Service 22
DID 010B - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 200 to 207 of the reply, 8 bits.
0xBB = 187 → (187 ÷ 50) = 3.74 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery › Modules › 151
HV battery module 151 voltage GV60_HVBAT_CMU151_VOLTConfirmed
- Request
22 01 0B - Service 22
DID 010B - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 208 to 215 of the reply, 8 bits.
0xBB = 187 → (187 ÷ 50) = 3.74 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery › Modules › 152
HV battery module 152 voltage GV60_HVBAT_CMU152_VOLTConfirmed
- Request
22 01 0B - Service 22
DID 010B - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 216 to 223 of the reply, 8 bits.
0xBB = 187 → (187 ÷ 50) = 3.74 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery › Modules › 153
HV battery module 153 voltage GV60_HVBAT_CMU153_VOLTConfirmed
- Request
22 01 0B - Service 22
DID 010B - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 224 to 231 of the reply, 8 bits.
0xBB = 187 → (187 ÷ 50) = 3.74 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery › Modules › 154
HV battery module 154 voltage GV60_HVBAT_CMU154_VOLTConfirmed
- Request
22 01 0B - Service 22
DID 010B - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 232 to 239 of the reply, 8 bits.
0xBB = 187 → (187 ÷ 50) = 3.74 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery › Modules › 155
HV battery module 155 voltage GV60_HVBAT_CMU155_VOLTConfirmed
- Request
22 01 0B - Service 22
DID 010B - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 240 to 247 of the reply, 8 bits.
0xBB = 187 → (187 ÷ 50) = 3.74 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery › Modules › 156
HV battery module 156 voltage GV60_HVBAT_CMU156_VOLTConfirmed
- Request
22 01 0B - Service 22
DID 010B - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 248 to 255 of the reply, 8 bits.
0xBB = 187 → (187 ÷ 50) = 3.74 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery › Modules › 157
HV battery module 157 voltage GV60_HVBAT_CMU157_VOLTConfirmed
- Request
22 01 0B - Service 22
DID 010B - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 256 to 263 of the reply, 8 bits.
0xBB = 187 → (187 ÷ 50) = 3.74 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery › Modules › 158
HV battery module 158 voltage GV60_HVBAT_CMU158_VOLTConfirmed
- Request
22 01 0B - Service 22
DID 010B - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 264 to 271 of the reply, 8 bits.
0xBB = 187 → (187 ÷ 50) = 3.74 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery › Modules › 159
HV battery module 159 voltage GV60_HVBAT_CMU159_VOLTConfirmed
- Request
22 01 0B - Service 22
DID 010B - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 272 to 279 of the reply, 8 bits.
0xBB = 187 → (187 ÷ 50) = 3.74 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery › Modules › 160
HV battery module 160 voltage GV60_HVBAT_CMU160_VOLTConfirmed
- Request
22 01 0B - Service 22
DID 010B - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 280 to 287 of the reply, 8 bits.
0xBB = 187 → (187 ÷ 50) = 3.74 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery › Modules › 161
HV battery module 161 voltage GV60_HVBAT_CMU161_VOLTConfirmed
- Request
22 01 0C - Service 22
DID 010C - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 32 to 39 of the reply, 8 bits.
0xBB = 187 → (187 ÷ 50) = 3.74 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery › Modules › 162
HV battery module 162 voltage GV60_HVBAT_CMU162_VOLTConfirmed
- Request
22 01 0C - Service 22
DID 010C - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 40 to 47 of the reply, 8 bits.
0xBB = 187 → (187 ÷ 50) = 3.74 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery › Modules › 163
HV battery module 163 voltage GV60_HVBAT_CMU163_VOLTConfirmed
- Request
22 01 0C - Service 22
DID 010C - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 48 to 55 of the reply, 8 bits.
0xBB = 187 → (187 ÷ 50) = 3.74 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery › Modules › 164
HV battery module 164 voltage GV60_HVBAT_CMU164_VOLTConfirmed
- Request
22 01 0C - Service 22
DID 010C - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 56 to 63 of the reply, 8 bits.
0xBB = 187 → (187 ÷ 50) = 3.74 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery › Modules › 165
HV battery module 165 voltage GV60_HVBAT_CMU165_VOLTConfirmed
- Request
22 01 0C - Service 22
DID 010C - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 64 to 71 of the reply, 8 bits.
0xBB = 187 → (187 ÷ 50) = 3.74 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery › Modules › 166
HV battery module 166 voltage GV60_HVBAT_CMU166_VOLTConfirmed
- Request
22 01 0C - Service 22
DID 010C - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 72 to 79 of the reply, 8 bits.
0xBB = 187 → (187 ÷ 50) = 3.74 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery › Modules › 167
HV battery module 167 voltage GV60_HVBAT_CMU167_VOLTConfirmed
- Request
22 01 0C - Service 22
DID 010C - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 80 to 87 of the reply, 8 bits.
0xBB = 187 → (187 ÷ 50) = 3.74 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery › Modules › 168
HV battery module 168 voltage GV60_HVBAT_CMU168_VOLTConfirmed
- Request
22 01 0C - Service 22
DID 010C - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 88 to 95 of the reply, 8 bits.
0xBB = 187 → (187 ÷ 50) = 3.74 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery › Modules › 169
HV battery module 169 voltage GV60_HVBAT_CMU169_VOLTConfirmed
- Request
22 01 0C - Service 22
DID 010C - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 96 to 103 of the reply, 8 bits.
0xBA = 186 → (186 ÷ 50) = 3.72 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery › Modules › 170
HV battery module 170 voltage GV60_HVBAT_CMU170_VOLTConfirmed
- Request
22 01 0C - Service 22
DID 010C - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 104 to 111 of the reply, 8 bits.
0xBB = 187 → (187 ÷ 50) = 3.74 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery › Modules › 171
HV battery module 171 voltage GV60_HVBAT_CMU171_VOLTConfirmed
- Request
22 01 0C - Service 22
DID 010C - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 112 to 119 of the reply, 8 bits.
0xBB = 187 → (187 ÷ 50) = 3.74 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery › Modules › 172
HV battery module 172 voltage GV60_HVBAT_CMU172_VOLTConfirmed
- Request
22 01 0C - Service 22
DID 010C - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 120 to 127 of the reply, 8 bits.
0xBA = 186 → (186 ÷ 50) = 3.72 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery › Modules › 173
HV battery module 173 voltage GV60_HVBAT_CMU173_VOLTConfirmed
- Request
22 01 0C - Service 22
DID 010C - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 128 to 135 of the reply, 8 bits.
0xBA = 186 → (186 ÷ 50) = 3.72 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery › Modules › 174
HV battery module 174 voltage GV60_HVBAT_CMU174_VOLTConfirmed
- Request
22 01 0C - Service 22
DID 010C - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 136 to 143 of the reply, 8 bits.
0xBB = 187 → (187 ÷ 50) = 3.74 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery › Modules › 175
HV battery module 175 voltage GV60_HVBAT_CMU175_VOLTConfirmed
- Request
22 01 0C - Service 22
DID 010C - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 144 to 151 of the reply, 8 bits.
0xBB = 187 → (187 ÷ 50) = 3.74 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery › Modules › 176
HV battery module 176 voltage GV60_HVBAT_CMU176_VOLTConfirmed
- Request
22 01 0C - Service 22
DID 010C - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 152 to 159 of the reply, 8 bits.
0xBB = 187 → (187 ÷ 50) = 3.74 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery › Modules › 177
HV battery module 177 voltage GV60_HVBAT_CMU177_VOLTConfirmed
- Request
22 01 0C - Service 22
DID 010C - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 160 to 167 of the reply, 8 bits.
0xBB = 187 → (187 ÷ 50) = 3.74 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery › Modules › 178
HV battery module 178 voltage GV60_HVBAT_CMU178_VOLTConfirmed
- Request
22 01 0C - Service 22
DID 010C - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 168 to 175 of the reply, 8 bits.
0xBB = 187 → (187 ÷ 50) = 3.74 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery › Modules › 179
HV battery module 179 voltage GV60_HVBAT_CMU179_VOLTConfirmed
- Request
22 01 0C - Service 22
DID 010C - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 176 to 183 of the reply, 8 bits.
0xBB = 187 → (187 ÷ 50) = 3.74 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery › Modules › 180
HV battery module 180 voltage GV60_HVBAT_CMU180_VOLTConfirmed
- Request
22 01 0C - Service 22
DID 010C - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 184 to 191 of the reply, 8 bits.
0xBB = 187 → (187 ÷ 50) = 3.74 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery › Modules › 181
HV battery module 181 voltage GV60_HVBAT_CMU181_VOLTConfirmed
- Request
22 01 0C - Service 22
DID 010C - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 192 to 199 of the reply, 8 bits.
0xBB = 187 → (187 ÷ 50) = 3.74 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery › Modules › 182
HV battery module 182 voltage GV60_HVBAT_CMU182_VOLTConfirmed
- Request
22 01 0C - Service 22
DID 010C - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 200 to 207 of the reply, 8 bits.
0xBB = 187 → (187 ÷ 50) = 3.74 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery › Modules › 183
HV battery module 183 voltage GV60_HVBAT_CMU183_VOLTConfirmed
- Request
22 01 0C - Service 22
DID 010C - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 208 to 215 of the reply, 8 bits.
0xBB = 187 → (187 ÷ 50) = 3.74 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery › Modules › 184
HV battery module 184 voltage GV60_HVBAT_CMU184_VOLTConfirmed
- Request
22 01 0C - Service 22
DID 010C - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 216 to 223 of the reply, 8 bits.
0xBB = 187 → (187 ÷ 50) = 3.74 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery › Modules › 185
HV battery module 185 voltage GV60_HVBAT_CMU185_VOLTConfirmed
- Request
22 01 0C - Service 22
DID 010C - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 224 to 231 of the reply, 8 bits.
0xBC = 188 → (188 ÷ 50) = 3.76 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery › Modules › 186
HV battery module 186 voltage GV60_HVBAT_CMU186_VOLTConfirmed
- Request
22 01 0C - Service 22
DID 010C - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 232 to 239 of the reply, 8 bits.
0xBC = 188 → (188 ÷ 50) = 3.76 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery › Modules › 187
HV battery module 187 voltage GV60_HVBAT_CMU187_VOLTConfirmed
- Request
22 01 0C - Service 22
DID 010C - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 240 to 247 of the reply, 8 bits.
0xBA = 186 → (186 ÷ 50) = 3.72 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery › Modules › 188
HV battery module 188 voltage GV60_HVBAT_CMU188_VOLTConfirmed
- Request
22 01 0C - Service 22
DID 010C - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 248 to 255 of the reply, 8 bits.
0xBB = 187 → (187 ÷ 50) = 3.74 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery › Modules › 189
HV battery module 189 voltage GV60_HVBAT_CMU189_VOLTConfirmed
- Request
22 01 0C - Service 22
DID 010C - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 256 to 263 of the reply, 8 bits.
0xBB = 187 → (187 ÷ 50) = 3.74 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery › Modules › 190
HV battery module 190 voltage GV60_HVBAT_CMU190_VOLTConfirmed
- Request
22 01 0C - Service 22
DID 010C - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 264 to 271 of the reply, 8 bits.
0xBB = 187 → (187 ÷ 50) = 3.74 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery › Modules › 191
HV battery module 191 voltage GV60_HVBAT_CMU191_VOLTConfirmed
- Request
22 01 0C - Service 22
DID 010C - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 272 to 279 of the reply, 8 bits.
0xBB = 187 → (187 ÷ 50) = 3.74 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.
Battery › Modules › 192
HV battery module 192 voltage GV60_HVBAT_CMU192_VOLTConfirmed
- Request
22 01 0C - Service 22
DID 010C - Module
7E4 → 7EC - Every
1 s - Testing for 2022, 2024 to 2026
Example reply from a 2023 Genesis GV60.
Bits 280 to 287 of the reply, 8 bits.
0xBA = 186 → (186 ÷ 50) = 3.72 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2023. In testing for 2022, 2024 to 2026.