Genesis GV60

Climate parameters

The Genesis GV60 has 10 climate parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

A/C compressor operation RPM GV60_AC_COMPRESSOR_OPERATION_RPMConfirmed

  • Request22 01 14
  • Service 22DID 0114
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 208 to 223 of the reply, 16 bits.

0x0000 = 0 → (0 × 20) = 0 rpm

Formula
(val × 20)
Range
0 to 1310700 rpm
Unit
rpm

Confirmed for 2023. In testing for 2022, 2024 to 2026.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

A/C compressor operation RPM GV60_AC_COMPRESSOR_OPERATION_RPMConfirmed

  • Request22 01 14
  • Service 22DID 0114
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 208 to 223 of the reply, 16 bits.

0x0000 = 0 → (0 × 20) = 0 rpm

Formula
(val × 20)
Range
0 to 1310700 rpm
Unit
rpm

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Air conditioning compressor speed GV60_AC_COMP_RPMConfirmed

  • Request22 01 06
  • Service 22DID 0106
  • Module7E4 → 7EC
  • Every5 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 96 to 103 of the reply, 8 bits.

0x00 = 0 → (0 × 20) = 0 rpm

Formula
(val × 20)
Range
0 to 5100 rpm
Unit
rpm

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Evaporator temperature GV60_HVAC_EVAPORATOR_TConfirmed

  • Request22 01 00
  • Service 22DID 0100
  • Module7B3 → 7BB
  • Every250 ms
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 56 to 63 of the reply, 8 bits.

0x70 = 112 → (112 ÷ 2 − 40) = 16 °C

Formula
(val ÷ 2 − 40)
Range
-40 to 87.5 °C
Unit
°C

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Humidity sensor for automatic defogger GV60_HVAC_HUMIDITY_SENSOR_FOR_AUTOMATIC_DEFOGGERConfirmed

  • Request22 01 00
  • Service 22DID 0100
  • Module7B3 → 7BB
  • Every250 ms
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 200 to 207 of the reply, 8 bits.

0x54 = 84 → 84 %

Formula
val
Range
0 to 100 %
Unit
%

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Interior temperature, driver legs vent GV60_HVAC_IAT_DRIVER_LEGS_VENTConfirmed

  • Request22 01 00
  • Service 22DID 0100
  • Module7B3 → 7BB
  • Every250 ms
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 224 to 231 of the reply, 8 bits.

0x72 = 114 → (114 ÷ 2 − 40) = 17 °C

Formula
(val ÷ 2 − 40)
Range
-40 to 87.5 °C
Unit
°C

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Interior temperature, driver vent GV60_HVAC_IAT_DRIVER_VENTConfirmed

  • Request22 01 00
  • Service 22DID 0100
  • Module7B3 → 7BB
  • Every250 ms
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 216 to 223 of the reply, 8 bits.

0x73 = 115 → (115 ÷ 2 − 40) = 17.5 °C

Formula
(val ÷ 2 − 40)
Range
-40 to 87.5 °C
Unit
°C

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Interior temperature, front GV60_HVAC_IATConfirmed

  • Request22 01 00
  • Service 22DID 0100
  • Module7B3 → 7BB
  • Every250 ms
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 40 to 47 of the reply, 8 bits.

0x72 = 114 → (114 ÷ 2 − 40) = 17 °C

Formula
(val ÷ 2 − 40)
Range
-40 to 87.5 °C
Unit
°C

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Interior temperature, passenger legs vent GV60_HVAC_IAT_PASSENGER_LEGS_VENTConfirmed

  • Request22 01 01
  • Service 22DID 0101
  • Module7B3 → 7BB
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 72 to 79 of the reply, 8 bits.

0x75 = 117 → (117 ÷ 2 − 40) = 18.5 °C

Formula
(val ÷ 2 − 40)
Range
-40 to 87.5 °C
Unit
°C

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Interior temperature, passenger vent GV60_HVAC_IAT_PASSENGER_VENTConfirmed

  • Request22 01 01
  • Service 22DID 0101
  • Module7B3 → 7BB
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 64 to 71 of the reply, 8 bits.

0x6B = 107 → (107 ÷ 2 − 40) = 13.5 °C

Formula
(val ÷ 2 − 40)
Range
-40 to 87.5 °C
Unit
°C

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Outdoor temperature GV60_HVAC_AATConfirmed

  • Request22 01 00
  • Service 22DID 0100
  • Module7B3 → 7BB
  • Every250 ms
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 48 to 55 of the reply, 8 bits.

0x6D = 109 → (109 ÷ 2 − 40) = 14.5 °C

Formula
(val ÷ 2 − 40)
Range
-40 to 87.5 °C
Unit
°C

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Keyboard shortcuts

jk/↓↑
Move down or up through a list or a grid.
hl/←→
Move across a row or between cards.
Enter
Open the focused link.
f
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.