Engine parameters
The BMW 5 Series has 110 engine parameters.
● Confirmed◆ In testing○ Supported× Not supported
02S Bank 3, Sensor 1 present O2S31_EXISTSSAE J1979Confirmed
- Request
01 1D - Service 01
PID 1D - Module
7E0 → 7E8 - Every
3600 s
Bit 3 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2009. Supported for 2004, 2021.
02S Bank 3, Sensor 2 present O2S32_EXISTSSAE J1979Confirmed
- Request
01 1D - Service 01
PID 1D - Module
7E0 → 7E8 - Every
3600 s
Bit 2 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2009. Supported for 2004, 2021.
02S Bank 4, Sensor 1 present O2S41_EXISTSSAE J1979Confirmed
- Request
01 1D - Service 01
PID 1D - Module
7E0 → 7E8 - Every
3600 s
Bit 1 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2009. Supported for 2004, 2021.
02S Bank 4, Sensor 2 present O2S42_EXISTSSAE J1979Confirmed
- Request
01 1D - Service 01
PID 1D - Module
7E0 → 7E8 - Every
3600 s
Bit 0 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2009. Supported for 2004, 2021.
Accelerator pedal position 5SERIES_APP
- Request
22 DE 9C - Service 22
DID DE9C - Module
6F1 → 612 - Every
1 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
(val ÷ 16)- Range
- 0 to 4095 %
- Unit
- %
In testing for 2011 to 2013, 2015 to 2016, 2018 to 2019, 2022 to 2026. Not supported for 2014, 2017, 2020 to 2021.
Air conditioning compressor PWM 5SERIES_AC_COMP_PWMConfirmed
- Request
22 D9 06 - Service 22
DID D906 - Module
6F1 → 640 - Every
1 s - Testing for 1988 to 2016, 2018 to 2019, 2022 to 2026
Example reply from a 2021 BMW 5 Series.
Bits 16 to 23 of the reply, 8 bits.
0x00 = 0 → 0 %
- Formula
val- Range
- 0 to 255 %
- Unit
- %
Confirmed for 2017, 2020 to 2021. In testing for 2011 to 2013, 2015 to 2016, 2018 to 2019, 2022 to 2026. Not supported for 2014.
Air conditioning compressor status 5SERIES_AC_COMP_STATConfirmed
- Request
22 D9 06 - Service 22
DID D906 - Module
6F1 → 640 - Every
1 s - Testing for 1988 to 2016, 2018 to 2019, 2022 to 2026
Example reply from a 2021 BMW 5 Series.
Bits 8 to 15 of the reply, 8 bits.
0x00 = 0 → 0
- Formula
val- Range
- 0 to 255
- Unit
- Number
Confirmed for 2017, 2020 to 2021. In testing for 2011 to 2013, 2015 to 2016, 2018 to 2019, 2022 to 2026. Not supported for 2014.
Air flow rate from mass air flow sensor MAFSAE J1979Confirmed
Pelican can show this parameter as the mass air flow.
- Request
01 10 - Service 01
PID 10 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655.35 g/s
- Unit
- g/s
Confirmed for 2009, 2011, 2013, 2015, 2020 to 2021. Supported for 2004, 2008, 2010, 2012, 2014, 2016 to 2019, 2022 to 2023.
AT engine torque 5SERIES_ENG_TQ
- Request
21 08 - Service 21
PID 08 - Module
6F1 → 618 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
val- Range
- -32768 to 32767 N·m
- Unit
- N·m
In testing for 2011 to 2013, 2015 to 2016, 2018 to 2019, 2022 to 2026. Not supported for 2014, 2017, 2020 to 2021.
Automatic air recirculation 5SERIES_HVAC_AUCConfirmed
- Request
22 D9 30 - Service 22
DID D930 - Module
6F1 → 678 - Every
5 s - Testing for 1988 to 2013, 2015 to 2026
Example reply from a 2014 BMW 5 Series.
Bits 0 to 7 of the reply, 8 bits.
0x00 = 0 → 0
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
Confirmed for 2014. In testing for 2011 to 2013, 2015 to 2016, 2018 to 2019, 2022 to 2026. Not supported for 2017, 2020 to 2021.
Automatic transmission fluid temperature 5SERIES_ATF_T
- Request
21 0A - Service 21
PID 0A - Module
6F1 → 618 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 55)- Range
- -55 to 200 °C
- Unit
- °C
In testing for 2011 to 2012, 2015 to 2016, 2018 to 2019, 2022 to 2026. Not supported for 2013 to 2014, 2017, 2020 to 2021.
Automatic transmission fluid temperature 5SERIES_ATF_TEMPConfirmed
Pelican can show this parameter as the transmission fluid temperature.
- Request
22 DA 12 - Service 22
DID DA12 - Module
6F1 → 618 - Every
30 s - Testing for 1988 to 2010, 2024 to 2026
Example reply from a 2023 BMW 5 Series.
Bits 0 to 15 of the reply, 16 bits.
0x004A = 74 → (74 − 48) = 26 °C
- Formula
(val − 48)- Range
- -48 to 65487 °C
- Unit
- °C
Confirmed for 2011 to 2023. In testing for 2007 to 2008, 2010, 2024 to 2026. Not supported for 1998, 2003 to 2006, 2009.
Barometric pressure 5SERIES_BAROConfirmed
- Request
22 42 01 - Service 22
DID 4201 - Module
6F1 → 612 - Every
5 s - Testing for 1988 to 2013, 2015 to 2016, 2018 to 2019, 2022 to 2026
Example reply from a 2021 BMW 5 Series.
Bits 0 to 15 of the reply, 16 bits.
0x60F2 = 24818 → (24818 ÷ 256) = 96.945313 kPa
- Formula
(val ÷ 256)- Range
- 0 to 255.99 kPa
- Unit
- kPa
Confirmed for 2014, 2017, 2020 to 2021. In testing for 2011 to 2013, 2015 to 2016, 2018 to 2019, 2022 to 2026.
Boost pressure 5SERIES_BOOST_PConfirmed
- Request
22 42 05 - Service 22
DID 4205 - Module
6F1 → 612 - Every
250 ms - Testing for 1988 to 2013, 2015 to 2016, 2018 to 2019, 2022 to 2026
Example reply from a 2021 BMW 5 Series.
Bits 0 to 15 of the reply, 16 bits.
0x3070 = 12400 → (12400 ÷ 128) = 96.875 kPa
- Formula
(val ÷ 128)- Range
- 0 to 511.99 kPa
- Unit
- kPa
Confirmed for 2014, 2017, 2020 to 2021. In testing for 2011 to 2013, 2015 to 2016, 2018 to 2019, 2022 to 2026.
Boost pressure, set point 5SERIES_BOOST_P_SETConfirmed
- Request
22 4A B0 - Service 22
DID 4AB0 - Module
6F1 → 612 - Every
250 ms - Testing for 1988 to 2013, 2015 to 2019, 2022 to 2026
Example reply from a 2021 BMW 5 Series.
Bits 0 to 15 of the reply, 16 bits.
0x6BC0 = 27584 → (27584 ÷ 256) = 107.75 kPa
- Formula
(val ÷ 256)- Range
- 0 to 255.99 kPa
- Unit
- kPa
Confirmed for 2014, 2020 to 2021. In testing for 2011 to 2013, 2015 to 2016, 2018 to 2019, 2022 to 2026. Not supported for 2017.
Cabin temperature 5SERIES_CABIN_T
- Request
22 D8 5C - Service 22
DID D85C - Module
6F1 → 678 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
val- Range
- -128 to 127 °C
- Unit
- °C
In testing for 2011 to 2013, 2015 to 2016, 2018 to 2019, 2022 to 2026. Not supported for 2014, 2017, 2020 to 2021.
Calculated engine load LOAD_PCTSAE J1979Confirmed
Represents the amount of work the engine is doing. Expected to reach 100% at wide open throttle/wide open pedal at any altitude, temperature or rpm for both naturally aspirated and boosted engines. If engine load is limited for powertrain protection e.g. engine/turbocharger protection, this value may not reach 100%. For hybrid vehicles, indicates the torque produced only by the internal combustion engine, not the torque being delivered by the entire powertrain. For electric vehicles, the meaning of this parameter is undefined.
Pelican can show this parameter as the engine load.
- Request
01 04 - Service 01
PID 04 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2009, 2011, 2013, 2015, 2021. Supported for 2004, 2008, 2010, 2012, 2014, 2016 to 2020, 2022 to 2023.
Catalyst temperature 5SERIES_CAT_TConfirmed
- Request
22 58 2F - Service 22
DID 582F - Module
6F1 → 612 - Every
5 s - Testing for 1988 to 2019, 2022 to 2026
Example reply from a 2021 BMW 5 Series.
Bits 0 to 15 of the reply, 16 bits.
0x0AAB = 2731 → (2731 ÷ 10 − 273.15) = -0.05 °C
- Formula
(val ÷ 10 − 273.15)- Range
- -273.15 to 6280 °C
- Unit
- °C
Confirmed for 2020 to 2021. In testing for 2011 to 2013, 2015 to 2016, 2018 to 2019, 2022 to 2026. Not supported for 2014, 2017.
Charge cycle efficiency 5SERIES_OBC_EFF_CYCLE
- Request
22 DE 85 - Service 22
DID DE85 - Module
6F1 → 615 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 %
- Unit
- %
In testing for 2011 to 2013, 2015 to 2016, 2018 to 2019, 2022 to 2026. Not supported for 2014, 2017, 2020 to 2021.
Charger 12V supply voltage 5SERIES_OBC_KL30_V
- Request
22 DE 86 - Service 22
DID DE86 - Module
6F1 → 615 - Every
5 s - Testing
Bits 48 to 55 of the reply, 8 bits.
- Formula
(val ÷ 10)- Range
- 0 to 25.5 V
- Unit
- V
In testing for 2011 to 2013, 2015 to 2016, 2018 to 2019, 2022 to 2026. Not supported for 2014, 2017, 2020 to 2021.
Charger AC current, phase 1 5SERIES_OBC_AC_I_1
- Request
22 DE 87 - Service 22
DID DE87 - Module
6F1 → 615 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553 A
- Unit
- A
In testing for 2011 to 2013, 2015 to 2016, 2018 to 2019, 2022 to 2026. Not supported for 2014, 2017, 2020 to 2021.
Charger AC current, phase 2 5SERIES_OBC_AC_I_2
- Request
22 DE 87 - Service 22
DID DE87 - Module
6F1 → 615 - Every
5 s - Testing
Bits 80 to 95 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553 A
- Unit
- A
In testing for 2011 to 2013, 2015 to 2016, 2018 to 2019, 2022 to 2026. Not supported for 2014, 2017, 2020 to 2021.
Charger AC current, phase 3 5SERIES_OBC_AC_I_3
- Request
22 DE 87 - Service 22
DID DE87 - Module
6F1 → 615 - Every
5 s - Testing
Bits 96 to 111 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553 A
- Unit
- A
In testing for 2011 to 2013, 2015 to 2016, 2018 to 2019, 2022 to 2026. Not supported for 2014, 2017, 2020 to 2021.
Charger AC voltage, phase 1 5SERIES_OBC_AC_V_1
- Request
22 DE 86 - Service 22
DID DE86 - Module
6F1 → 615 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 V
- Unit
- V
In testing for 2011 to 2013, 2015 to 2016, 2018 to 2019, 2022 to 2026. Not supported for 2014, 2017, 2020 to 2021.
Charger AC voltage, phase 2 5SERIES_OBC_AC_V_2
- Request
22 DE 86 - Service 22
DID DE86 - Module
6F1 → 615 - Every
5 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 V
- Unit
- V
In testing for 2011 to 2013, 2015 to 2016, 2018 to 2019, 2022 to 2026. Not supported for 2014, 2017, 2020 to 2021.
Charger AC voltage, phase 3 5SERIES_OBC_AC_V_3
- Request
22 DE 86 - Service 22
DID DE86 - Module
6F1 → 615 - Every
5 s - Testing
Bits 80 to 95 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 V
- Unit
- V
In testing for 2011 to 2013, 2015 to 2016, 2018 to 2019, 2022 to 2026. Not supported for 2014, 2017, 2020 to 2021.
Charger DC efficiency 5SERIES_OBC_EFF_DC
- Request
22 DE 85 - Service 22
DID DE85 - Module
6F1 → 615 - Every
5 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 %
- Unit
- %
In testing for 2011 to 2013, 2015 to 2016, 2018 to 2019, 2022 to 2026. Not supported for 2014, 2017, 2020 to 2021.
Charger grid frequency, phase 1 5SERIES_OBC_GRID_HZ
- Request
22 DE 84 - Service 22
DID DE84 - Module
6F1 → 615 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 4)- Range
- 0 to 63.75 Hz
- Unit
- Hz
In testing for 2011 to 2013, 2015 to 2016, 2018 to 2019, 2022 to 2026. Not supported for 2014, 2017, 2020 to 2021.
Charger HV DC current 5SERIES_OBC_HV_I
- Request
22 DE 87 - Service 22
DID DE87 - Module
6F1 → 615 - Every
5 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
(val ÷ 10 − 204.7)- Range
- -204 to 6348 A
- Unit
- A
In testing for 2011 to 2013, 2015 to 2016, 2018 to 2019, 2022 to 2026. Not supported for 2014, 2017, 2020 to 2021.
Charger HV DC voltage 5SERIES_OBC_HV_V
- Request
22 DE 86 - Service 22
DID DE86 - Module
6F1 → 615 - Every
5 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553 V
- Unit
- V
In testing for 2011 to 2013, 2015 to 2016, 2018 to 2019, 2022 to 2026. Not supported for 2014, 2017, 2020 to 2021.
Charger HV output power 5SERIES_OBC_PWR
- Request
22 DE 85 - Service 22
DID DE85 - Module
6F1 → 615 - Every
5 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 W
- Unit
- W
In testing for 2011 to 2013, 2015 to 2016, 2018 to 2019, 2022 to 2026. Not supported for 2014, 2017, 2020 to 2021.
Charger power reduction 5SERIES_OBC_DERATING
- Request
22 DE 84 - Service 22
DID DE84 - Module
6F1 → 615 - Every
5 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 %
- Unit
- %
In testing for 2011 to 2013, 2015 to 2016, 2018 to 2019, 2022 to 2026. Not supported for 2014, 2017, 2020 to 2021.
Charging cable current rating 5SERIES_CHG_CABLE_IConfirmed
- Request
22 DE F5 - Service 22
DID DEF5 - Module
6F1 → 614 - Every
5 s - Testing for 1988 to 2020, 2022 to 2026
Example reply from a 2021 BMW 5 Series.
Bits 8 to 15 of the reply, 8 bits.
0xFD = 253 → 253 A
- Formula
val- Range
- 0 to 255 A
- Unit
- A
Confirmed for 2021. In testing for 2011 to 2013, 2015 to 2016, 2018 to 2019, 2022 to 2026. Not supported for 2014, 2017, 2020.
Charging plug state 5SERIES_CHG_PLUG_STConfirmed
- Request
22 DE F5 - Service 22
DID DEF5 - Module
6F1 → 614 - Every
5 s - Testing for 1988 to 2020, 2022 to 2026
Example reply from a 2021 BMW 5 Series.
Bits 0 to 7 of the reply, 8 bits.
0x00 = 0 → 0
- Formula
val- Range
- 0 to 255
- Unit
- Number
Confirmed for 2021. In testing for 2011 to 2013, 2015 to 2016, 2018 to 2019, 2022 to 2026. Not supported for 2014, 2017, 2020.
Climate control off 5SERIES_HVAC_OFFConfirmed
- Request
22 D9 2C - Service 22
DID D92C - Module
6F1 → 678 - Every
5 s - Testing for 1988 to 2013, 2015 to 2026
Example reply from a 2014 BMW 5 Series.
Bits 0 to 7 of the reply, 8 bits.
0x00 = 0 → 0
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
Confirmed for 2014. In testing for 2011 to 2013, 2015 to 2016, 2018 to 2019, 2022 to 2026. Not supported for 2017, 2020 to 2021.
Commanded equivalence ratio EQ_RATSAE J1979Confirmed
Fuel systems that utilize conventional oxygen sensor display the inverse of the commanded open loop equivalence ratio (also known as lambda) while the fuel control system is in open loop. Will indicate 1.000 while in closed-loop fuel.
Pelican can show this parameter as the commanded lambda.
- Request
01 44 - Service 01
PID 44 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 2 ÷ 65535)- Range
- 0 to 1.99
- Unit
- Number
Confirmed for 2009, 2020 to 2021, 2023. Supported for 2008, 2010 to 2019, 2022.
Consumption, kwh/100km 5SERIES_CONS_KWH_100KMConfirmed
- Request
22 D1 2A - Service 22
DID D12A - Module
6F1 → 660 - Every
1 s - Testing for 1988 to 2016, 2018 to 2019, 2022 to 2026
Example reply from a 2021 BMW 5 Series.
Bits 0 to 15 of the reply, 16 bits.
0x0041 = 65 → (65 ÷ 10) = 6.5
- Formula
(val ÷ 10)- Range
- 0 to 6553
- Unit
- Number
Confirmed for 2017, 2020 to 2021. In testing for 2011 to 2013, 2015 to 2016, 2018 to 2019, 2022 to 2026. Not supported for 2014.
Coolant temperature 5SERIES_COOLANTConfirmed
- Request
22 41 1E - Service 22
DID 411E - Module
6F1 → 612 - Every
1 s - Testing for 1988 to 2019, 2022 to 2026
Example reply from a 2021 BMW 5 Series.
Bits 16 to 23 of the reply, 8 bits.
0x00 = 0 → 0 °C
- Formula
val- Range
- 0 to 200 °C
- Unit
- °C
Confirmed for 2020 to 2021. In testing for 2011 to 2012, 2015 to 2016, 2018 to 2019, 2022 to 2026. Not supported for 2013 to 2014, 2017.
Crank torque 5SERIES_CRANK_TQConfirmed
- Request
22 58 BA - Service 22
DID 58BA - Module
6F1 → 612 - Every
250 ms - Testing for 1988 to 2013, 2015 to 2019, 2022 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553 N·m
- Unit
- N·m
Confirmed for 2014, 2020 to 2021. In testing for 2011 to 2013, 2015 to 2016, 2018 to 2019, 2022 to 2026. Not supported for 2017.
DC charging pin cover open 5SERIES_DC_PIN_COVER
- Request
22 DE FA - Service 22
DID DEFA - Module
6F1 → 614 - Every
30 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2011 to 2013, 2015 to 2016, 2018 to 2019, 2022 to 2026. Not supported for 2014, 2017, 2020 to 2021.
Drive electronics processor 0 temperature 5SERIES_EME_T_MC0
- Request
22 DE 8C - Service 22
DID DE8C - Module
6F1 → 61A - Every
5 s - Testing
Bits 208 to 223 of the reply, 16 bits. The value is signed.
- Formula
(val × 39 ÷ 2500)- Range
- -511 to 511 °C
- Unit
- °C
In testing for 2011 to 2013, 2015 to 2016, 2018 to 2019, 2022 to 2026. Not supported for 2014, 2017, 2020 to 2021.
Drive electronics processor 2 temperature 5SERIES_EME_T_MC2
- Request
22 DE 8C - Service 22
DID DE8C - Module
6F1 → 61A - Every
5 s - Testing
Bits 224 to 239 of the reply, 16 bits. The value is signed.
- Formula
(val × 39 ÷ 2500)- Range
- -511 to 511 °C
- Unit
- °C
In testing for 2011 to 2013, 2015 to 2016, 2018 to 2019, 2022 to 2026. Not supported for 2014, 2017, 2020 to 2021.
Drive inverter gate driver temperature 5SERIES_INV_T_GATE
- Request
22 DE 8C - Service 22
DID DE8C - Module
6F1 → 61A - Every
5 s - Testing
Bits 48 to 63 of the reply, 16 bits. The value is signed.
- Formula
(val × 39 ÷ 2500)- Range
- -511 to 511 °C
- Unit
- °C
In testing for 2011 to 2013, 2015 to 2016, 2018 to 2019, 2022 to 2026. Not supported for 2014, 2017, 2020 to 2021.
Drive inverter HV DC current 5SERIES_EM_INV_I_DC
- Request
22 DE 8A - Service 22
DID DE8A - Module
6F1 → 61A - Every
1 s - Testing
Bits 64 to 79 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276 to 3276 A
- Unit
- A
In testing for 2011 to 2013, 2015 to 2016, 2018 to 2019, 2022 to 2026. Not supported for 2014, 2017, 2020 to 2021.
Drive inverter phase u temperature 5SERIES_INV_T_U
- Request
22 DE 8C - Service 22
DID DE8C - Module
6F1 → 61A - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val × 39 ÷ 2500)- Range
- -511 to 511 °C
- Unit
- °C
In testing for 2011 to 2013, 2015 to 2016, 2018 to 2019, 2022 to 2026. Not supported for 2014, 2017, 2020 to 2021.
Drive inverter phase v temperature 5SERIES_INV_T_V
- Request
22 DE 8C - Service 22
DID DE8C - Module
6F1 → 61A - Every
5 s - Testing
Bits 16 to 31 of the reply, 16 bits. The value is signed.
- Formula
(val × 39 ÷ 2500)- Range
- -511 to 511 °C
- Unit
- °C
In testing for 2011 to 2013, 2015 to 2016, 2018 to 2019, 2022 to 2026. Not supported for 2014, 2017, 2020 to 2021.
Drive inverter phase w temperature 5SERIES_INV_T_W
- Request
22 DE 8C - Service 22
DID DE8C - Module
6F1 → 61A - Every
5 s - Testing
Bits 32 to 47 of the reply, 16 bits. The value is signed.
- Formula
(val × 39 ÷ 2500)- Range
- -511 to 511 °C
- Unit
- °C
In testing for 2011 to 2013, 2015 to 2016, 2018 to 2019, 2022 to 2026. Not supported for 2014, 2017, 2020 to 2021.
Drive motor excitation current 5SERIES_EM_I_EXC
- Request
22 DE 8A - Service 22
DID DE8A - Module
6F1 → 61A - Every
1 s - Testing
Bits 48 to 63 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 16)- Range
- -2048 to 2047 A
- Unit
- A
In testing for 2011 to 2013, 2015 to 2016, 2018 to 2019, 2022 to 2026. Not supported for 2014, 2017, 2020 to 2021.
Drive motor phase u current 5SERIES_EM_I_U
- Request
22 DE 8A - Service 22
DID DE8A - Module
6F1 → 61A - Every
1 s - Testing
Bits 32 to 47 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 16)- Range
- -2048 to 2047 A
- Unit
- A
In testing for 2011 to 2013, 2015 to 2016, 2018 to 2019, 2022 to 2026. Not supported for 2014, 2017, 2020 to 2021.
Drive motor phase v current 5SERIES_EM_I_V
- Request
22 DE 8A - Service 22
DID DE8A - Module
6F1 → 61A - Every
1 s - Testing
Bits 16 to 31 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 16)- Range
- -2048 to 2047 A
- Unit
- A
In testing for 2011 to 2013, 2015 to 2016, 2018 to 2019, 2022 to 2026. Not supported for 2014, 2017, 2020 to 2021.
Drive motor phase w current 5SERIES_EM_I_W
- Request
22 DE 8A - Service 22
DID DE8A - Module
6F1 → 61A - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 16)- Range
- -2048 to 2047 A
- Unit
- A
In testing for 2011 to 2013, 2015 to 2016, 2018 to 2019, 2022 to 2026. Not supported for 2014, 2017, 2020 to 2021.
Drive motor speed 5SERIES_EM_RPM
- Request
22 DE A7 - Service 22
DID DEA7 - Module
6F1 → 61A - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 2 − 5000)- Range
- -5000 to 27767 rpm
- Unit
- rpm
In testing for 2011 to 2013, 2015 to 2016, 2018 to 2019, 2022 to 2026. Not supported for 2014, 2017, 2020 to 2021.
Drive motor temperature 1 5SERIES_EM_T_1
- Request
22 DE A6 - Service 22
DID DEA6 - Module
6F1 → 61A - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val × 39 ÷ 2500)- Range
- -511 to 511 °C
- Unit
- °C
In testing for 2011 to 2013, 2015 to 2016, 2018 to 2019, 2022 to 2026. Not supported for 2014, 2017, 2020 to 2021.
Drive motor temperature 2 5SERIES_EM_T_2
- Request
22 DE A6 - Service 22
DID DEA6 - Module
6F1 → 61A - Every
5 s - Testing
Bits 16 to 31 of the reply, 16 bits. The value is signed.
- Formula
(val × 39 ÷ 2500)- Range
- -511 to 511 °C
- Unit
- °C
In testing for 2011 to 2013, 2015 to 2016, 2018 to 2019, 2022 to 2026. Not supported for 2014, 2017, 2020 to 2021.
Drive motor torque, actual 5SERIES_EM_TQ
- Request
22 DE A7 - Service 22
DID DEA7 - Module
6F1 → 61A - Every
250 ms - Testing
Bits 16 to 31 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 2)- Range
- -16384 to 16383 N·m
- Unit
- N·m
In testing for 2011 to 2013, 2015 to 2016, 2018 to 2019, 2022 to 2026. Not supported for 2014, 2017, 2020 to 2021.
Drive motor torque, requested 5SERIES_EM_TQ_TGT
- Request
22 DE A7 - Service 22
DID DEA7 - Module
6F1 → 61A - Every
250 ms - Testing
Bits 32 to 47 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 2)- Range
- -16384 to 16383 N·m
- Unit
- N·m
In testing for 2011 to 2013, 2015 to 2016, 2018 to 2019, 2022 to 2026. Not supported for 2014, 2017, 2020 to 2021.
Engine coolant temperature ECTSAE J1979Confirmed
Your engine temperature must operate within a certain temperature range to operate efficiently and safely. If it runs too hot, then your engine could be permanently damaged. If it runs too cold, then your engine will use more fuel than necessary.
Pelican can show this parameter as the engine coolant temperature.
- Request
01 05 - Service 01
PID 05 - Module
7E0 → 7E8 - Every
500 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2009, 2011, 2013, 2015, 2021. Supported for 2004, 2008, 2010, 2012, 2014, 2016 to 2020, 2022 to 2023.
Engine load 5SERIES_LOADConfirmed
Pelican can show this parameter as the engine load.
- Request
22 58 13 - Service 22
DID 5813 - Module
6F1 → 612 - Every
250 ms - Testing for 1988 to 2013, 2015 to 2019, 2022 to 2026
Example reply from a 2021 BMW 5 Series.
Bits 0 to 7 of the reply, 8 bits.
0x1C = 28 → (28 × 0.75) = 21 %
- Formula
(val × 0.75)- Range
- 0 to 191.25 %
- Unit
- %
Confirmed for 2014, 2020 to 2021. In testing for 2011 to 2013, 2015 to 2016, 2018 to 2019, 2022 to 2026. Not supported for 2017.
Engine load 2 5SERIES_LOAD_2Confirmed
- Request
22 4A 4B - Service 22
DID 4A4B - Module
6F1 → 612 - Every
1 s - Testing for 1988 to 2013, 2015 to 2019, 2022 to 2026
Example reply from a 2021 BMW 5 Series.
Bits 0 to 7 of the reply, 8 bits.
0x00 = 0 → (0 × 20 ÷ 51) = 0 %
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2014, 2020 to 2021. In testing for 2011 to 2013, 2015 to 2016, 2018 to 2019, 2022 to 2026. Not supported for 2017.
Engine load, target 5SERIES_LOAD_TGTConfirmed
- Request
22 48 0C - Service 22
DID 480C - Module
6F1 → 612 - Every
1 s - Testing for 1988 to 2013, 2015 to 2019, 2022 to 2026
Example reply from a 2021 BMW 5 Series.
Bits 0 to 15 of the reply, 16 bits.
0x0482 = 1154 → (1154 × 3 ÷ 128) = 27.046875 %
- Formula
(val × 3 ÷ 128)- Range
- 0 to 1535 %
- Unit
- %
Confirmed for 2014, 2020 to 2021. In testing for 2011 to 2013, 2015 to 2016, 2018 to 2019, 2022 to 2026. Not supported for 2017.
Engine oil temperature 5SERIES_EOTConfirmed
Pelican can show this parameter as the engine oil temperature.
- Request
22 DA 25 - Service 22
DID DA25 - Module
6F1 → 618 - Every
1 s - Testing for 1988 to 2010, 2024 to 2026
Example reply from a 2023 BMW 5 Series.
Bits 0 to 15 of the reply, 16 bits.
0x002E = 46 → (46 − 48) = -2 °C
- Formula
(val − 48)- Range
- -48 to 65487 °C
- Unit
- °C
Confirmed for 2011 to 2023. In testing for 2007 to 2008, 2010, 2024 to 2026. Not supported for 1998, 2003 to 2006, 2009.
Engine oil temperature 5SERIES_EOT_6F1Confirmed
Pelican can show this parameter as the engine oil temperature.
- Request
22 44 02 - Service 22
DID 4402 - Module
6F1 → 612 - Every
1 s - Testing for 1988 to 2013, 2015 to 2019, 2022 to 2026
Example reply from a 2021 BMW 5 Series.
Bits 8 to 15 of the reply, 8 bits.
0x6A = 106 → (106 ÷ 2) = 53 °C
- Formula
(val ÷ 2)- Range
- 0 to 127.5 °C
- Unit
- °C
Confirmed for 2014, 2020 to 2021. In testing for 2011 to 2012, 2015 to 2016, 2018 to 2019, 2022 to 2026. Not supported for 2013, 2017.
Engine oil temperature 5SERIES_EOT_DMEConfirmed
Pelican can show this parameter as the engine oil temperature.
- Request
22 44 08 - Service 22
DID 4408 - Module
6F1 → 612 - Every
5 s - Testing for 1988 to 2013, 2015 to 2017
Example reply from a 2014 BMW 5 Series.
Bits 0 to 15 of the reply, 16 bits.
0x03A3 = 931 → (931 ÷ 10) = 93.1 °C
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 °C
- Unit
- °C
Confirmed for 2014. In testing for 1988 to 2013, 2015 to 2016. Not supported for 2017.
Engine oil temperature 5SERIES_EOT_DME_KConfirmed
Pelican can show this parameter as the engine oil temperature.
- Request
22 44 08 - Service 22
DID 4408 - Module
6F1 → 612 - Every
5 s - Testing for 2022 to 2026
Example reply from a 2021 BMW 5 Series.
Bits 0 to 15 of the reply, 16 bits.
0x0BF1 = 3057 → (3057 ÷ 10 − 273.15) = 32.55 °C
- Formula
(val ÷ 10 − 273.15)- Range
- -273.15 to 6280 °C
- Unit
- °C
Confirmed for 2020 to 2021. In testing for 2022 to 2026.
Engine oil temperature 5SERIES_OIL_TEMPConfirmed
Pelican can show this parameter as the engine oil temperature.
- Request
22 45 06 - Service 22
DID 4506 - Module
6F1 → 612 - Every
1 s - Testing for 1988 to 2013, 2015 to 2016, 2018 to 2019, 2022 to 2026
Example reply from a 2021 BMW 5 Series.
Bits 0 to 7 of the reply, 8 bits.
0x00 = 0 → 0 °C
- Formula
val- Range
- 0 to 200 °C
- Unit
- °C
Confirmed for 2014, 2017, 2020 to 2021. In testing for 2011 to 2012, 2015 to 2016, 2018 to 2019, 2022 to 2026. Not supported for 2013.
Engine oil temperature EOTSAE J1979Confirmed
Pelican can show this parameter as the engine oil temperature.
- Request
01 5C - Service 01
PID 5C - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 210 °C
- Unit
- °C
Confirmed for 2020 to 2021. Supported for 2016 to 2019, 2022 to 2023.
Engine oil temperature, alternate 5SERIES_OIL_TEMP_ALT
Pelican can show this parameter as the engine oil temperature.
- Request
22 57 C3 - Service 22
DID 57C3 - Module
6F1 → 612 - Every
1 s - Testing for 1988 to 2016
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 200 °C
- Unit
- °C
In testing for 2011 to 2012, 2015 to 2016. Supported for 2017. Not supported for 2013 to 2014.
Engine RPM RPMSAE J1979Confirmed
- Request
01 0C - Service 01
PID 0C - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4)- Range
- 0 to 16383.75 rpm
- Unit
- rpm
Confirmed for 2021. Supported for 2004, 2008 to 2020, 2022 to 2023.
Engine temperature 5SERIES_ETConfirmed
Pelican can show this parameter as the engine coolant temperature.
- Request
22 43 00 - Service 22
DID 4300 - Module
6F1 → 612 - Every
1 s - Testing for 2018 to 2019, 2022 to 2026
Example reply from a 2021 BMW 5 Series.
Bits 0 to 15 of the reply, 16 bits.
0x0BF1 = 3057 → (3057 ÷ 10 − 273.15) = 32.55 °C
- Formula
(val ÷ 10 − 273.15)- Range
- -273.15 to 6280 °C
- Unit
- °C
Confirmed for 2020 to 2021. In testing for 2018 to 2019, 2022 to 2026. Not supported for 2017.
Engine temperature 5SERIES_ET_8Confirmed
Pelican can show this parameter as the engine coolant temperature.
- Request
22 43 00 - Service 22
DID 4300 - Module
6F1 → 612 - Every
1 s - Testing for 1988 to 2013, 2015
Example reply from a 2014 BMW 5 Series.
Bits 0 to 7 of the reply, 8 bits.
0xBC = 188 → (188 × 3 ÷ 4 − 48) = 93 °C
- Formula
(val × 3 ÷ 4 − 48)- Range
- -48 to 143.25 °C
- Unit
- °C
Confirmed for 2014. In testing for 1988 to 2012, 2015. Not supported for 2013.
Engine torque 5SERIES_ENG_TQ_6F1Confirmed
- Request
22 44 2F - Service 22
DID 442F - Module
6F1 → 618 - Every
250 ms - Testing for 1988 to 2013, 2015 to 2016, 2018 to 2019, 2022 to 2026
Example reply from a 2021 BMW 5 Series.
Bits 0 to 15 of the reply, 16 bits.
0x001D = 29 → 29 N·m
- Formula
val- Range
- 0 to 65535 N·m
- Unit
- N·m
Confirmed for 2014, 2017, 2020 to 2021. In testing for 2011 to 2013, 2015 to 2016, 2018 to 2019, 2022 to 2026.
Exhaust gas calculated temperature 5SERIES_EGT_CALCConfirmed
- Request
22 4C 5B - Service 22
DID 4C5B - Module
6F1 → 612 - Every
1 s - Testing for 1988 to 2020, 2022 to 2026
Example reply from a 2021 BMW 5 Series.
Bits 16 to 31 of the reply, 16 bits.
0x04B3 = 1203 → (1203 ÷ 10) = 120.3 °C
- Formula
(val ÷ 10)- Range
- 0 to 1200 °C
- Unit
- °C
Confirmed for 2021. In testing for 2011 to 2012, 2015 to 2016, 2018 to 2019, 2022 to 2026. Not supported for 2013 to 2014, 2017, 2020.
Ignition angle 5SERIES_IGN_ANGLEConfirmed
- Request
22 59 FA - Service 22
DID 59FA - Module
6F1 → 612 - Every
1 s - Testing for 1988 to 2016, 2018 to 2019, 2022 to 2026
Example reply from a 2021 BMW 5 Series.
Bits 0 to 7 of the reply, 8 bits. The value is signed.
0x00 = 0 → (0 × 0.75) = 0 °
- Formula
(val × 0.75)- Range
- -96 to 95.25 °
- Unit
- °
Confirmed for 2017, 2020 to 2021. In testing for 2011 to 2013, 2015 to 2016, 2018 to 2019, 2022 to 2026. Not supported for 2014.
Ignition timing, cylinder 1 5SERIES_IGN_TIMING_1Confirmed
- Request
22 4A 49 - Service 22
DID 4A49 - Module
6F1 → 612 - Every
1 s - Testing for 1988 to 2013, 2015 to 2019, 2022 to 2026
Example reply from a 2021 BMW 5 Series.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
0xFFA1 = -95 → (-95 ÷ 10) = -9.5 °
- Formula
(val ÷ 10)- Range
- -3276 to 3276 °
- Unit
- °
Confirmed for 2014, 2020 to 2021. In testing for 2011 to 2013, 2015 to 2016, 2018 to 2019, 2022 to 2026. Not supported for 2017.
Ignition timing, cylinder 2 5SERIES_IGN_TIMING_2Confirmed
- Request
22 4A 4A - Service 22
DID 4A4A - Module
6F1 → 612 - Every
1 s - Testing for 1988 to 2013, 2015 to 2019, 2022 to 2026
Example reply from a 2021 BMW 5 Series.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
0xFFA1 = -95 → (-95 ÷ 10) = -9.5 °
- Formula
(val ÷ 10)- Range
- -3276 to 3276 °
- Unit
- °
Confirmed for 2014, 2020 to 2021. In testing for 2011 to 2013, 2015 to 2016, 2018 to 2019, 2022 to 2026. Not supported for 2017.
Ignition timing, cylinder 3 5SERIES_IGN_TIMING_3Confirmed
- Request
22 4A 4C - Service 22
DID 4A4C - Module
6F1 → 612 - Every
1 s - Testing for 1988 to 2013, 2015 to 2019, 2022 to 2026
Example reply from a 2021 BMW 5 Series.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
0xFFA1 = -95 → (-95 ÷ 10) = -9.5 °
- Formula
(val ÷ 10)- Range
- -3276 to 3276 °
- Unit
- °
Confirmed for 2014, 2020 to 2021. In testing for 2011 to 2013, 2015 to 2016, 2018 to 2019, 2022 to 2026. Not supported for 2017.
Ignition timing, cylinder 4 5SERIES_IGN_TIMING_4Confirmed
- Request
22 4A 4D - Service 22
DID 4A4D - Module
6F1 → 612 - Every
1 s - Testing for 1988 to 2013, 2015 to 2019, 2022 to 2026
Example reply from a 2021 BMW 5 Series.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
0xFFA1 = -95 → (-95 ÷ 10) = -9.5 °
- Formula
(val ÷ 10)- Range
- -3276 to 3276 °
- Unit
- °
Confirmed for 2014, 2020 to 2021. In testing for 2011 to 2013, 2015 to 2016, 2018 to 2019, 2022 to 2026. Not supported for 2017.
Intake air temperature 5SERIES_IATConfirmed
- Request
22 40 15 - Service 22
DID 4015 - Module
6F1 → 612 - Every
1 s - Testing for 1988 to 2013, 2015 to 2019, 2022 to 2026
Example reply from a 2021 BMW 5 Series.
Bits 8 to 15 of the reply, 8 bits.
0x62 = 98 → 98 °C
- Formula
val- Range
- 0 to 150 °C
- Unit
- °C
Confirmed for 2014, 2020 to 2021. In testing for 2011 to 2012, 2015 to 2016, 2018 to 2019, 2022 to 2026. Not supported for 2013, 2017.
Intake air temperature 5SERIES_IAT_DMEConfirmed
- Request
22 58 0F - Service 22
DID 580F - Module
6F1 → 612 - Every
5 s - Testing for 1988 to 2013, 2015 to 2019, 2022 to 2026
Example reply from a 2021 BMW 5 Series.
Bits 0 to 7 of the reply, 8 bits.
0x70 = 112 → (112 × 0.75 − 48) = 36 °C
- Formula
(val × 0.75 − 48)- Range
- -48 to 143.25 °C
- Unit
- °C
Confirmed for 2014, 2020 to 2021. In testing for 2011 to 2013, 2015 to 2016, 2018 to 2019, 2022 to 2026. Not supported for 2017.
Intake manifold absolute pressure MAPSAE J1979Confirmed
- Request
01 0B - Service 01
PID 0B - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 kPa
- Unit
- kPa
Confirmed for 2017. Supported for 2004, 2009 to 2016, 2018 to 2023.
Intake manifold pressure 5SERIES_MAPConfirmed
- Request
22 4A 2D - Service 22
DID 4A2D - Module
6F1 → 612 - Every
250 ms - Testing for 1988 to 2013, 2015 to 2019, 2022 to 2026
Example reply from a 2021 BMW 5 Series.
Bits 0 to 15 of the reply, 16 bits.
0x307F = 12415 → (12415 ÷ 128) = 96.992188 kPa
- Formula
(val ÷ 128)- Range
- 0 to 511.99 kPa
- Unit
- kPa
Confirmed for 2014, 2020 to 2021. In testing for 2011 to 2013, 2015 to 2016, 2018 to 2019, 2022 to 2026. Not supported for 2017.
Kickdown 5SERIES_KICKDOWNConfirmed
- Request
22 DA 1F - Service 22
DID DA1F - Module
6F1 → 618 - Every
1 s - Testing for 1988 to 2010, 2024 to 2026
Example reply from a 2023 BMW 5 Series.
Bits 8 to 15 of the reply, 8 bits.
0x00 = 0 → 0
- Formula
val- Range
- 0 to 100
- Unit
- Number
Confirmed for 2011 to 2023. In testing for 2007 to 2008, 2010, 2024 to 2026. Not supported for 1998, 2003 to 2006, 2009.
Lambda 5SERIES_LAMBDA_6F1Confirmed
- Request
22 58 89 - Service 22
DID 5889 - Module
6F1 → 612 - Every
1 s - Testing for 1988 to 2013, 2015 to 2019, 2022 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 16 ÷ 65535)- Range
- 0 to 16
- Unit
- Number
Confirmed for 2014, 2020 to 2021. In testing for 2011 to 2013, 2015 to 2016, 2018 to 2019, 2022 to 2026. Not supported for 2017.
Lambda 1, excess air ratio 5SERIES_LAMBDAConfirmed
- Request
22 40 0B - Service 22
DID 400B - Module
6F1 → 612 - Every
1 s - Testing for 1988 to 2013, 2015 to 2019, 2022 to 2026
Example reply from a 2021 BMW 5 Series.
Bits 40 to 47 of the reply, 8 bits.
0x00 = 0 → (0 ÷ 100) = 0
- Formula
(val ÷ 100)- Range
- 0 to 2
- Unit
- Number
Confirmed for 2014, 2020 to 2021. In testing for 2011 to 2012, 2015 to 2016, 2018 to 2019, 2022 to 2026. Not supported for 2013, 2017.
Lambda 2 5SERIES_LAMBDA_2Confirmed
- Request
22 58 2C - Service 22
DID 582C - Module
6F1 → 612 - Every
1 s - Testing for 1988 to 2013, 2015 to 2019, 2022 to 2026
Example reply from a 2021 BMW 5 Series.
Bits 0 to 15 of the reply, 16 bits.
0x0000 = 0 → (0 ÷ 4096) = 0
- Formula
(val ÷ 4096)- Range
- 0 to 15.99
- Unit
- Number
Confirmed for 2014, 2020 to 2021. In testing for 2011 to 2013, 2015 to 2016, 2018 to 2019, 2022 to 2026. Not supported for 2017.
Oil level 5SERIES_OIL_LEVELConfirmed
- Request
22 44 2C - Service 22
DID 442C - Module
6F1 → 612 - Every
30 s - Testing for 1988 to 2013, 2015 to 2016, 2018 to 2019, 2022 to 2026
Example reply from a 2021 BMW 5 Series.
Bits 0 to 7 of the reply, 8 bits.
0x52 = 82 → 82
- Formula
val- Range
- 0 to 255
- Unit
- Number
Confirmed for 2014, 2017, 2020 to 2021. In testing for 2011 to 2013, 2015 to 2016, 2018 to 2019, 2022 to 2026.
On-board charger board temperature 5SERIES_OBC_T_BOARD
- Request
22 DE 8C - Service 22
DID DE8C - Module
6F1 → 61A - Every
5 s - Testing
Bits 176 to 191 of the reply, 16 bits. The value is signed.
- Formula
(val × 39 ÷ 2500)- Range
- -511 to 511 °C
- Unit
- °C
In testing for 2011 to 2013, 2015 to 2016, 2018 to 2019, 2022 to 2026. Not supported for 2014, 2017, 2020 to 2021.
Outside temperature, climate control 5SERIES_IHX_AATConfirmed
- Request
22 D9 6B - Service 22
DID D96B - Module
6F1 → 678 - Every
5 s - Testing for 1988 to 2013, 2015 to 2026
Example reply from a 2014 BMW 5 Series.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
0x0084 = 132 → (132 ÷ 2 − 40) = 26 °C
- Formula
(val ÷ 2 − 40)- Range
- -16424 to 16343 °C
- Unit
- °C
Confirmed for 2014. In testing for 2011 to 2013, 2015 to 2016, 2018 to 2019, 2022 to 2026. Not supported for 2017, 2020 to 2021.
Recirculation 5SERIES_HVAC_RECIRCConfirmed
- Request
22 D9 31 - Service 22
DID D931 - Module
6F1 → 678 - Every
5 s - Testing for 1988 to 2013, 2015 to 2026
Example reply from a 2014 BMW 5 Series.
Bits 0 to 7 of the reply, 8 bits.
0x00 = 0 → 0
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
Confirmed for 2014. In testing for 2011 to 2013, 2015 to 2016, 2018 to 2019, 2022 to 2026. Not supported for 2017, 2020 to 2021.
Rev limiter 5SERIES_REV_LIMITConfirmed
- Request
22 4A 2E - Service 22
DID 4A2E - Module
6F1 → 612 - Every
3600 s - Testing for 1988 to 2013, 2015 to 2019, 2022 to 2026
Example reply from a 2021 BMW 5 Series.
Bits 0 to 15 of the reply, 16 bits.
0x1770 = 6000 → 6,000 rpm
- Formula
val- Range
- 0 to 65535 rpm
- Unit
- rpm
Confirmed for 2014, 2020 to 2021. In testing for 2011 to 2013, 2015 to 2016, 2018 to 2019, 2022 to 2026. Not supported for 2017.
Short term fuel trim (bank 1) SHRTFT1SAE J1979Confirmed
Correction being used by the closed-loop fuel algorithm.
Pelican can show this parameter as the short term fuel trim.
- Request
01 06 - Service 01
PID 06 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 128 − 100)- Range
- -100 to 99.2 %
- Unit
- %
Confirmed for 2020 to 2021. Supported for 2004, 2008 to 2019, 2022 to 2023.
Speed from satellite positioning 5SERIES_GPS_SPDConfirmed
- Request
22 D0 30 - Service 22
DID D030 - Module
6F1 → 663 - Every
1 s - Testing for 1988 to 2013, 2015 to 2016, 2018 to 2026
Example reply from a 2017 BMW 5 Series.
Bits 80 to 95 of the reply, 16 bits. The value is signed.
0x0000 = 0 → 0 km/h
- Formula
val- Range
- -32768 to 32767 km/h
- Unit
- km/h
Confirmed for 2014, 2017. In testing for 2011 to 2013, 2015 to 2016, 2018 to 2019, 2022 to 2026. Not supported for 2020 to 2021.
Steering torque 5SERIES_STEER_TQConfirmed
- Request
22 DB 99 - Service 22
DID DB99 - Module
6F1 → 630 - Every
1 s - Testing for 1988 to 2016, 2018 to 2019, 2022 to 2026
Example reply from a 2021 BMW 5 Series.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
0x000C = 12 → (12 ÷ 128) = 0.09375 N·m
- Formula
(val ÷ 128)- Range
- -256 to 255 N·m
- Unit
- N·m
Confirmed for 2017, 2020 to 2021. In testing for 2011 to 2013, 2015 to 2016, 2018 to 2019, 2022 to 2026. Not supported for 2014.
Trip computer average consumption 5SERIES_BC_AVG_CONSConfirmed
- Request
22 D1 29 - Service 22
DID D129 - Module
6F1 → 660 - Every
30 s - Testing for 1988 to 2016, 2018 to 2019, 2022 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553 kWh/100 km
- Unit
- kWh/100 km
Confirmed for 2017, 2020 to 2021. In testing for 2011 to 2013, 2015 to 2016, 2018 to 2019, 2022 to 2026. Not supported for 2014.
Trip computer average speed 5SERIES_BC_AVG_SPDConfirmed
- Request
22 D1 29 - Service 22
DID D129 - Module
6F1 → 660 - Every
30 s - Testing for 1988 to 2016, 2018 to 2019, 2022 to 2026
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655 km/h
- Unit
- km/h
Confirmed for 2017, 2020 to 2021. In testing for 2011 to 2013, 2015 to 2016, 2018 to 2019, 2022 to 2026. Not supported for 2014.
Trip computer range 5SERIES_BC_RANGEConfirmed
- Request
22 D1 29 - Service 22
DID D129 - Module
6F1 → 660 - Every
30 s - Testing for 1988 to 2016, 2018 to 2019, 2022 to 2026
Example reply from a 2021 BMW 5 Series.
Bits 48 to 63 of the reply, 16 bits.
0x001E = 30 → (30 ÷ 10) = 3 km
- Formula
(val ÷ 10)- Range
- 0 to 6553 km
- Unit
- km
Confirmed for 2017, 2020 to 2021. In testing for 2011 to 2013, 2015 to 2016, 2018 to 2019, 2022 to 2026. Not supported for 2014.
Variable geometry turbocharger calibration angle 5SERIES_VGT_CAL_ANGLEConfirmed
- Request
22 DF E7 - Service 22
DID DFE7 - Module
6F1 → 619 - Every
1 s - Testing for 2023 to 2026
Example reply from a 2022 BMW 5 Series.
Bits 0 to 15 of the reply, 16 bits.
0x03C7 = 967 → (967 × 156.25 ÷ 10000) = 15.109375 °
- Formula
(val × 156.25 ÷ 10000)- Range
- 0 to 1000 °
- Unit
- °
Confirmed for 2018 to 2022. In testing for 2024 to 2026. Supported for 2017. Not supported for 1998, 2003 to 2004, 2012 to 2013, 2015 to 2016, 2023.
Wheel sensor speed 1 5SERIES_NBT_WHL_SPD_1Confirmed
- Request
22 D0 30 - Service 22
DID D030 - Module
6F1 → 663 - Every
1 s - Testing for 1988 to 2013, 2015 to 2016, 2018 to 2026
Example reply from a 2017 BMW 5 Series.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
0x0000 = 0 → 0 km/h
- Formula
val- Range
- -32768 to 32767 km/h
- Unit
- km/h
Confirmed for 2014, 2017. In testing for 2011 to 2013, 2015 to 2016, 2018 to 2019, 2022 to 2026. Not supported for 2020 to 2021.
Wheel sensor speed 2 5SERIES_NBT_WHL_SPD_2Confirmed
- Request
22 D0 30 - Service 22
DID D030 - Module
6F1 → 663 - Every
1 s - Testing for 1988 to 2013, 2015 to 2016, 2018 to 2026
Example reply from a 2017 BMW 5 Series.
Bits 16 to 31 of the reply, 16 bits. The value is signed.
0x0000 = 0 → 0 km/h
- Formula
val- Range
- -32768 to 32767 km/h
- Unit
- km/h
Confirmed for 2014, 2017. In testing for 2011 to 2013, 2015 to 2016, 2018 to 2019, 2022 to 2026. Not supported for 2020 to 2021.
Wheel sensor speed 3 5SERIES_NBT_WHL_SPD_3Confirmed
- Request
22 D0 30 - Service 22
DID D030 - Module
6F1 → 663 - Every
1 s - Testing for 1988 to 2013, 2015 to 2016, 2018 to 2026
Example reply from a 2017 BMW 5 Series.
Bits 32 to 47 of the reply, 16 bits. The value is signed.
0x0000 = 0 → 0 km/h
- Formula
val- Range
- -32768 to 32767 km/h
- Unit
- km/h
Confirmed for 2014, 2017. In testing for 2011 to 2013, 2015 to 2016, 2018 to 2019, 2022 to 2026. Not supported for 2020 to 2021.
Wheel sensor speed 4 5SERIES_NBT_WHL_SPD_4Confirmed
- Request
22 D0 30 - Service 22
DID D030 - Module
6F1 → 663 - Every
1 s - Testing for 1988 to 2013, 2015 to 2016, 2018 to 2026
Example reply from a 2017 BMW 5 Series.
Bits 48 to 63 of the reply, 16 bits. The value is signed.
0x0000 = 0 → 0 km/h
- Formula
val- Range
- -32768 to 32767 km/h
- Unit
- km/h
Confirmed for 2014, 2017. In testing for 2011 to 2013, 2015 to 2016, 2018 to 2019, 2022 to 2026. Not supported for 2020 to 2021.
Yaw rate 5SERIES_YAW_RATE
- Request
21 04 - Service 21
PID 04 - Module
6F1 → 629 - Every
250 ms - Testing
Bits 48 to 63 of the reply, 16 bits. The value is signed.
- Formula
(val × 0.4 ÷ 100)- Range
- -131.072 to 131.068 m/s²
- Unit
- m/s²
In testing for 2011 to 2012, 2015 to 2016, 2018 to 2019, 2022 to 2026. Not supported for 2013 to 2014, 2017, 2020 to 2021.
Engine › OxygenSensors
02S Bank 1, Sensor 1 present O2S11_EXISTSSAE J1979Confirmed
- Request
01 13 - Service 01
PID 13 - Module
7E0 → 7E8 - Every
3600 s
Bit 7 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2009. Supported for 2004, 2008, 2010 to 2023.
02S Bank 1, Sensor 2 present O2S12_EXISTSSAE J1979Confirmed
- Request
01 13 - Service 01
PID 13 - Module
7E0 → 7E8 - Every
3600 s
Bit 6 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2009. Supported for 2004, 2008, 2010 to 2023.
02S Bank 2, Sensor 1 present O2S21_EXISTSSAE J1979Confirmed
- Request
01 13 - Service 01
PID 13 - Module
7E0 → 7E8 - Every
3600 s
Bit 3 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2009. Supported for 2004, 2008, 2010 to 2023.
02S Bank 2, Sensor 2 present O2S22_EXISTSSAE J1979Confirmed
- Request
01 13 - Service 01
PID 13 - Module
7E0 → 7E8 - Every
3600 s
Bit 2 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2009. Supported for 2004, 2008, 2010 to 2023.
Lambda value, Equivalence Ratio Bank 1, Sensor 1 LAMBDA11_CURRENTSAE J1979Confirmed
Pelican can show this parameter as the O2 lambda.
- Request
01 34 - Service 01
PID 34 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 32768)- Range
- 0 to 1.99
- Unit
- Number
Confirmed for 2009, 2021. Supported for 2011 to 2020, 2022 to 2023.
Lambda value, Equivalence Ratio Bank 1, Sensor 1 LAMBDA11_VOLTSAE J1979Confirmed
Pelican can show this parameter as the O2 lambda.
- Request
01 24 - Service 01
PID 24 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 32768)- Range
- 0 to 1.99
- Unit
- Number
Confirmed for 2009, 2013, 2015. Supported for 2004, 2010 to 2012, 2014.
Wide Range O2S Current, O2 Sensor Bank 1, Sensor 1 O2S11_CURRENTSAE J1979Confirmed
- Request
01 34 - Service 01
PID 34 - Module
7E0 → 7E8 - Every
250 ms
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val ÷ 256 − 128)- Range
- -128 to 127.996 mA
- Unit
- mA
Confirmed for 2009, 2021. Supported for 2011 to 2020, 2022 to 2023.
Wide Range O2S Voltage, O2 Sensor Bank 1, Sensor 1 O2S11_VOLTSAE J1979Confirmed
- Request
01 24 - Service 01
PID 24 - Module
7E0 → 7E8 - Every
250 ms
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val ÷ 8196)- Range
- 0 to 7.999 V
- Unit
- V
Confirmed for 2009, 2013, 2015. Supported for 2004, 2010 to 2012, 2014.