A/C clutch ACURA_AC_CLU_PCM
- Request
22 26 10 - Service 22
DID 2610 - Module
DA0E → 0E - Every
1 s - Testing
Bit 262 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 1996 to 2014.
Active cylinders ACURA_ACTIVE_CYL
- Request
22 26 15 - Service 22
DID 2615 - Module
DA10 → 10 - Every
500 ms - Testing
Bits 400 to 407 of the reply, 8 bits.
- Formula
val- Range
- 0 to 6
- Unit
- Number
In testing for 1996 to 2006, 2008 to 2011, 2013 to 2014. Not supported for 2007, 2012.
Active cylinders ACURA_ACTIVE_CYL_PCM
- Request
22 26 15 - Service 22
DID 2615 - Module
DA0E → 0E - Every
1 s - Testing
Bits 400 to 407 of the reply, 8 bits.
- Formula
val- Range
- 0 to 6
- Unit
- Number
In testing for 1996 to 2014.
Air conditioner clutch ACURA_AC_CLU_DA11
- Request
22 26 10 - Service 22
DID 2610 - Module
DA11 → 11 - Every
1 s - Testing
Bit 262 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 1996 to 2014.
Air conditioning pressure, raw count ACURA_AC_P_RAW_CNT
- Request
22 26 13 - Service 22
DID 2613 - Module
DA11 → 11 - Every
1 s - Testing
Bits 120 to 135 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 1996 to 2014.
Air flow rate from mass air flow sensor MAFSAE J1979Confirmed
Pelican can show this parameter as the mass air flow.
- Request
01 10 - Service 01
PID 10 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655.35 g/s
- Unit
- g/s
Confirmed for 2012.
Air/gas ratio ACURA_AIRGAS_RAT
- Request
22 26 11 - Service 22
DID 2611 - Module
DA10 → 10 - Every
250 ms - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
(val × 29.4 ÷ 65535)- Range
- 0 to 29.4
- Unit
- Number
In testing for 1996 to 2014.
Air/gas ratio ACURA_AIRGAS_RAT_PCM
- Request
22 26 11 - Service 22
DID 2611 - Module
DA0E → 0E - Every
1 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
(val × 29.4 ÷ 65535)- Range
- 0 to 29.4
- Unit
- Number
In testing for 1996 to 2014.
Air/gas ratio ACURA_AIRGAS_RATIO
- Request
22 26 11 - Service 22
DID 2611 - Module
DA10 → 10 - Every
250 ms - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
(val × 29.4 ÷ 65535)- Range
- 0 to 29.4
- Unit
- Number
In testing for 1996 to 2006, 2008 to 2011, 2013 to 2014. Not supported for 2007, 2012.
Air/gas ratio ACURA_AIRGAS_RATIO_PCM
- Request
22 26 11 - Service 22
DID 2611 - Module
DA0E → 0E - Every
1 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
(val × 29.4 ÷ 65535)- Range
- 0 to 29.4
- Unit
- Number
In testing for 1996 to 2014.
Air/gas ratio ACURA_AIRGAS_RATIO_V2
- Request
22 26 11 - Service 22
DID 2611 - Module
DA11 → 11 - Every
5 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
(val × 29.4 ÷ 65535)- Range
- 0 to 29.4
- Unit
- Number
In testing for 1996 to 2006, 2008 to 2011, 2013 to 2014. Not supported for 2007, 2012.
Ambient air temperature, cabin ACURA_AAT_CAB
- Request
22 20 2A - Service 22
DID 202A - Module
DA01 → 01 - Every
1 s - Testing
Bits 832 to 839 of the reply, 8 bits. The value is signed.
- Formula
val- Range
- -40 to 127 °C
- Unit
- °C
In testing for 1996 to 2014.
Ambient air temperature, outside ACURA_AAT_OUT
- Request
22 20 2A - Service 22
DID 202A - Module
DA01 → 01 - Every
1 s - Testing
Bits 840 to 847 of the reply, 8 bits. The value is signed.
- Formula
val- Range
- -40 to 127 °C
- Unit
- °C
In testing for 1996 to 2014.
Cabin air temperature ACURA_CABIN_AIR_TEMPERATURE
- Request
22 20 01 - Service 22
DID 2001 - Module
DBEF - Every
5 s - Testing
Bits 200 to 207 of the reply, 8 bits.
- Formula
(val × 1.8 + 32)- Range
- 0 to 491 °F
- Unit
- °F
In testing for 1996 to 2014.
Calculated engine load LOAD_PCTSAE J1979Confirmed
Represents the amount of work the engine is doing. Expected to reach 100% at wide open throttle/wide open pedal at any altitude, temperature or rpm for both naturally aspirated and boosted engines. If engine load is limited for powertrain protection e.g. engine/turbocharger protection, this value may not reach 100%. For hybrid vehicles, indicates the torque produced only by the internal combustion engine, not the torque being delivered by the entire powertrain. For electric vehicles, the meaning of this parameter is undefined.
Pelican can show this parameter as the engine load.
- Request
01 04 - Service 01
PID 04 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2012.
Catalyst temperature ACURA_CAT_T
- Request
22 26 62 - Service 22
DID 2662 - Module
DA11 → 11 - Every
5 s - Testing
Bits 96 to 111 of the reply, 16 bits.
- Formula
(val ÷ 10 − 40)- Range
- -40 to 1500 °C
- Unit
- °C
In testing for 1996 to 2006, 2008 to 2011, 2013 to 2014. Not supported for 2007, 2012.
Commanded equivalence ratio EQ_RATSAE J1979Confirmed
Fuel systems that utilize conventional oxygen sensor display the inverse of the commanded open loop equivalence ratio (also known as lambda) while the fuel control system is in open loop. Will indicate 1.000 while in closed-loop fuel.
Pelican can show this parameter as the commanded lambda.
- Request
01 44 - Service 01
PID 44 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 2 ÷ 65535)- Range
- 0 to 1.99
- Unit
- Number
Confirmed for 2012.
DC-DC converter temperature ACURA_DC_DC_CONVERTER_TEMPERATURE
- Request
22 20 10 - Service 22
DID 2010 - Module
DBEF - Every
5 s - Testing
Bits 104 to 119 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276.8 to 3276.7 °C
- Unit
- °C
In testing for 1996 to 2014.
Electric load detector current ACURA_ELD_ELEC_LOAD_DUTY
- Request
22 26 61 - Service 22
DID 2661 - Module
DA11 → 11 - Every
1 s - Testing
Bits 136 to 143 of the reply, 8 bits.
- Formula
(val ÷ 2)- Range
- 0 to 127 A
- Unit
- A
In testing for 1996 to 2014.
Electric motor load ACURA_ELEC_MOTOR_LOAD
- Request
22 26 68 - Service 22
DID 2668 - Module
DA11 → 11 - Every
1 s - Testing
Bits 216 to 223 of the reply, 8 bits.
- Formula
(val × 40 ÷ 51 − 100)- Range
- -100 to 100 %
- Unit
- %
In testing for 1996 to 2014.
Electric motor load ACURA_ELEC_MOTOR_LOAD_DA10
- Request
22 26 68 - Service 22
DID 2668 - Module
DA10 → 10 - Every
1 s - Testing
Bits 216 to 223 of the reply, 8 bits.
- Formula
(val × 40 ÷ 51 − 100)- Range
- -100 to 100 %
- Unit
- %
In testing for 1996 to 2014.
Engine coolant temperature ECTSAE J1979Confirmed
Your engine temperature must operate within a certain temperature range to operate efficiently and safely. If it runs too hot, then your engine could be permanently damaged. If it runs too cold, then your engine will use more fuel than necessary.
Pelican can show this parameter as the engine coolant temperature.
- Request
01 05 - Service 01
PID 05 - Module
7E0 → 7E8 - Every
500 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2012.
Engine coolant temperature sensor 1 ACURA_ECT_1
Pelican can show this parameter as the engine coolant temperature.
- Request
22 20 2C - Service 22
DID 202C - Module
DA01 → 01 - Every
5 s - Testing
Bits 1,608 to 1,623 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 1996 to 2014.
Engine coolant temperature sensor 2 ACURA_ECT_2
Pelican can show this parameter as the engine coolant temperature.
- Request
22 20 2C - Service 22
DID 202C - Module
DA01 → 01 - Every
5 s - Testing
Bits 1,624 to 1,639 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 1996 to 2014.
Engine coolant temperature sensor 3 ACURA_ECT_3
Pelican can show this parameter as the engine coolant temperature.
- Request
22 20 2C - Service 22
DID 202C - Module
DA01 → 01 - Every
5 s - Testing
Bits 1,640 to 1,655 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 1996 to 2014.
Engine coolant temperature sensor 4 ACURA_ECT_4
Pelican can show this parameter as the engine coolant temperature.
- Request
22 20 2C - Service 22
DID 202C - Module
DA01 → 01 - Every
5 s - Testing
Bits 1,656 to 1,671 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 1996 to 2014.
Engine oil level ACURA_OIL_LEVEL
- Request
22 26 66 - Service 22
DID 2666 - Module
DA11 → 11 - Every
5 s - Testing
Bits 48 to 55 of the reply, 8 bits.
- Formula
(val ÷ 2)- Range
- 0 to 127.5 mm
- Unit
- mm
In testing for 1996 to 2014.
Engine oil temperature, variant 1 ACURA_EOT_VAR_1
- Request
22 26 66 - Service 22
DID 2666 - Module
DA11 → 11 - Every
5 s - Testing
Bits 88 to 95 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 1996 to 2014.
Engine oil temperature, variant 2 ACURA_EOT_VAR_2
- Request
22 26 66 - Service 22
DID 2666 - Module
DA11 → 11 - Every
5 s - Testing
Bits 112 to 119 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 1996 to 2014.
Engine oil temperature, variant 3 ACURA_EOT_VAR_3
- Request
22 26 66 - Service 22
DID 2666 - Module
DA10 → 10 - Every
5 s - Testing
Bits 88 to 95 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 1996 to 2014.
Engine oil temperature, variant 3 ACURA_EOT_VAR_3_PCM
- Request
22 26 66 - Service 22
DID 2666 - Module
DA0E → 0E - Every
5 s - Testing
Bits 88 to 95 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 1996 to 2014.
Engine oil temperature, variant 4 ACURA_EOT_VAR_4
- Request
22 26 66 - Service 22
DID 2666 - Module
DA10 → 10 - Every
5 s - Testing
Bits 112 to 119 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 1996 to 2014.
Engine oil temperature, variant 4 ACURA_EOT_VAR_4_PCM
- Request
22 26 66 - Service 22
DID 2666 - Module
DA0E → 0E - Every
5 s - Testing
Bits 112 to 119 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 1996 to 2014.
Evaporative purge control load ACURA_EVAP_PC_LOAD
- Request
22 26 13 - Service 22
DID 2613 - Module
DA11 → 11 - Every
1 s - Testing
Bits 48 to 55 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 99.61 %
- Unit
- %
In testing for 1996 to 2014.
Fuel/air commanded equivalence ratio ACURA_FUELAIR_CAR
- Request
22 26 61 - Service 22
DID 2661 - Module
DA10 → 10 - Every
250 ms - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
(val ÷ 2229.081633)- Range
- 0 to 29.4
- Unit
- Number
In testing for 1996 to 2006, 2008 to 2011, 2013 to 2014. Not supported for 2007, 2012.
Fuel/air commanded equivalence ratio ACURA_FUELAIR_CAR_PCM
- Request
22 26 61 - Service 22
DID 2661 - Module
DA0E → 0E - Every
1 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
(val ÷ 2229.081633)- Range
- 0 to 29.4
- Unit
- Number
In testing for 1996 to 2014.
Generator ACURA_GEN
- Request
22 26 10 - Service 22
DID 2610 - Module
DA11 → 11 - Every
1 s - Testing
Bits 184 to 191 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 1996 to 2014.
Generator ACURA_GENERATOR
- Request
22 26 10 - Service 22
DID 2610 - Module
DA10 → 10 - Every
5 s - Testing
Bits 184 to 191 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
In testing for 1996 to 2006, 2008 to 2011, 2013 to 2014. Not supported for 2007, 2012.
Generator ACURA_GENERATOR_DA11
- Request
22 26 10 - Service 22
DID 2610 - Module
DA11 → 11 - Every
1 s - Testing
Bits 184 to 191 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
In testing for 1996 to 2014.
Generator ACURA_GENERATOR_PCM
- Request
22 26 10 - Service 22
DID 2610 - Module
DA0E → 0E - Every
1 s - Testing
Bits 184 to 191 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
In testing for 1996 to 2014.
Knock control ACURA_KNOCK_CONTROL
ECU's determination of fuel quality.
- Request
22 26 62 - Service 22
DID 2662 - Module
DA10 → 10 - Every
250 ms - Testing
Bits 80 to 87 of the reply, 8 bits.
- Formula
(val × 2 ÷ 255)- Range
- 0 to 2
- Unit
- Raw value
In testing for 1996 to 2006, 2008 to 2011, 2013 to 2014. Not supported for 2007, 2012.
Knock control ACURA_KNOCK_CONTROL_V2
- Request
22 26 62 - Service 22
DID 2662 - Module
DA11 → 11 - Every
5 s - Testing
Bits 80 to 87 of the reply, 8 bits.
- Formula
(val × 1.99 ÷ 255)- Range
- 0 to 1.99
- Unit
- Number
In testing for 1996 to 2006, 2008 to 2011, 2013 to 2014. Not supported for 2007, 2012.
Maintenance, air cleaner ACURA_MAINT_AIR_CLN
- Request
22 70 60 - Service 22
DID 7060 - Module
DA60 → 60 - Every
30 s - Testing
Bits 336 to 351 of the reply, 16 bits.
- Formula
val- Range
- 0 to 9999
- Unit
- Raw value
In testing for 1996 to 2014.
Maintenance, brake fluid ACURA_MAINT_BRK_FLD
- Request
22 70 60 - Service 22
DID 7060 - Module
DA60 → 60 - Every
30 s - Testing
Bits 320 to 335 of the reply, 16 bits.
- Formula
val- Range
- 0 to 9999
- Unit
- Raw value
In testing for 1996 to 2014.
Maintenance, cabin filter ACURA_MAINT_CABIN_FLT
- Request
22 70 60 - Service 22
DID 7060 - Module
DA60 → 60 - Every
30 s - Testing
Bits 240 to 255 of the reply, 16 bits.
- Formula
val- Range
- 0 to 9999
- Unit
- Raw value
In testing for 1996 to 2014.
Maintenance, engine coolant ACURA_MAINT_COOL
- Request
22 70 60 - Service 22
DID 7060 - Module
DA60 → 60 - Every
30 s - Testing
Bits 288 to 303 of the reply, 16 bits.
- Formula
val- Range
- 0 to 9999
- Unit
- Raw value
In testing for 1996 to 2014.
Maintenance, general inspection ACURA_MAINT_INSP
- Request
22 70 60 - Service 22
DID 7060 - Module
DA60 → 60 - Every
30 s - Testing
Bits 208 to 223 of the reply, 16 bits.
- Formula
val- Range
- 0 to 9999
- Unit
- Raw value
In testing for 1996 to 2014.
Maintenance, oil & filter ACURA_MAINT_OIL_FLT
- Request
22 70 60 - Service 22
DID 7060 - Module
DA60 → 60 - Every
30 s - Testing
Bits 112 to 127 of the reply, 16 bits.
- Formula
val- Range
- 0 to 9999
- Unit
- Raw value
In testing for 1996 to 2014.
Maintenance, spark plugs & valves ACURA_MAINT_SPARK
- Request
22 70 60 - Service 22
DID 7060 - Module
DA60 → 60 - Every
30 s - Testing
Bits 128 to 143 of the reply, 16 bits.
- Formula
val- Range
- 0 to 9999
- Unit
- Raw value
In testing for 1996 to 2014.
Maintenance, transmission fluid ACURA_MAINT_TRANS_FLD
- Request
22 70 60 - Service 22
DID 7060 - Module
DA60 → 60 - Every
30 s - Testing
Bits 256 to 271 of the reply, 16 bits.
- Formula
val- Range
- 0 to 9999
- Unit
- Raw value
In testing for 1996 to 2014.
Misfire count #1, variant 1 ACURA_MIS_CNT_1_VAR_1_PCM
- Request
22 26 6C - Service 22
DID 266C - Module
DA0E → 0E - Every
1 s - Testing
Bits 48 to 55 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1996 to 2014.
Misfire count #1, variant 1 ACURA_MISFIRE_COUNT_1_VAR_1
- Request
22 26 6C - Service 22
DID 266C - Module
DA11 → 11 - Every
1 s - Testing
Bits 48 to 55 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1996 to 2014.
Misfire count #1, variant 2 ACURA_MISFIRE_COUNT_1_VAR_2
- Request
22 26 63 - Service 22
DID 2663 - Module
DA11 → 11 - Every
1 s - Testing
Bits 272 to 287 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 1996 to 2014.
Misfire count #1, variant 3 ACURA_MIS_CNT_1_VAR_3_PCM
- Request
22 26 63 - Service 22
DID 2663 - Module
DA0E → 0E - Every
1 s - Testing
Bits 160 to 175 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 1996 to 2014.
Misfire count #1, variant 3 ACURA_MISFIRE_COUNT_1_VAR_3
- Request
22 26 63 - Service 22
DID 2663 - Module
DA11 → 11 - Every
1 s - Testing
Bits 160 to 175 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 1996 to 2014.
Misfire count #2, variant 1 ACURA_MIS_CNT_2_VAR_1_PCM
- Request
22 26 6C - Service 22
DID 266C - Module
DA0E → 0E - Every
1 s - Testing
Bits 56 to 63 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1996 to 2014.
Misfire count #2, variant 1 ACURA_MISFIRE_COUNT_2_VAR_1
- Request
22 26 6C - Service 22
DID 266C - Module
DA11 → 11 - Every
1 s - Testing
Bits 56 to 63 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1996 to 2014.
Misfire count #2, variant 2 ACURA_MISFIRE_COUNT_2_VAR_2
- Request
22 26 63 - Service 22
DID 2663 - Module
DA11 → 11 - Every
1 s - Testing
Bits 288 to 303 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 1996 to 2014.
Misfire count #2, variant 3 ACURA_MIS_CNT_2_VAR_3_PCM
- Request
22 26 63 - Service 22
DID 2663 - Module
DA0E → 0E - Every
1 s - Testing
Bits 176 to 191 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 1996 to 2014.
Misfire count #2, variant 3 ACURA_MISFIRE_COUNT_2_VAR_3
- Request
22 26 63 - Service 22
DID 2663 - Module
DA11 → 11 - Every
1 s - Testing
Bits 176 to 191 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 1996 to 2014.
Misfire count #3, variant 1 ACURA_MIS_CNT_3_VAR_1_PCM
- Request
22 26 6C - Service 22
DID 266C - Module
DA0E → 0E - Every
1 s - Testing
Bits 64 to 71 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1996 to 2014.
Misfire count #3, variant 1 ACURA_MISFIRE_COUNT_3_VAR_1
- Request
22 26 6C - Service 22
DID 266C - Module
DA11 → 11 - Every
1 s - Testing
Bits 64 to 71 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1996 to 2014.
Misfire count #3, variant 2 ACURA_MISFIRE_COUNT_3_VAR_2
- Request
22 26 63 - Service 22
DID 2663 - Module
DA11 → 11 - Every
1 s - Testing
Bits 304 to 319 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 1996 to 2014.
Misfire count #3, variant 3 ACURA_MIS_CNT_3_VAR_3_PCM
- Request
22 26 63 - Service 22
DID 2663 - Module
DA0E → 0E - Every
1 s - Testing
Bits 192 to 207 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 1996 to 2014.
Misfire count #3, variant 3 ACURA_MISFIRE_COUNT_3_VAR_3
- Request
22 26 63 - Service 22
DID 2663 - Module
DA11 → 11 - Every
1 s - Testing
Bits 192 to 207 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 1996 to 2014.
Misfire count #4, variant 1 ACURA_MIS_CNT_4_VAR_1_PCM
- Request
22 26 6C - Service 22
DID 266C - Module
DA0E → 0E - Every
1 s - Testing
Bits 72 to 79 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1996 to 2014.
Misfire count #4, variant 1 ACURA_MISFIRE_COUNT_4_VAR_1
- Request
22 26 6C - Service 22
DID 266C - Module
DA11 → 11 - Every
1 s - Testing
Bits 72 to 79 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1996 to 2014.
Misfire count #4, variant 2 ACURA_MISFIRE_COUNT_4_VAR_2
- Request
22 26 63 - Service 22
DID 2663 - Module
DA11 → 11 - Every
1 s - Testing
Bits 320 to 335 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 1996 to 2014.
Misfire count #4, variant 3 ACURA_MIS_CNT_4_VAR_3_PCM
- Request
22 26 63 - Service 22
DID 2663 - Module
DA0E → 0E - Every
1 s - Testing
Bits 208 to 223 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 1996 to 2014.
Misfire count #4, variant 3 ACURA_MISFIRE_COUNT_4_VAR_3
- Request
22 26 63 - Service 22
DID 2663 - Module
DA11 → 11 - Every
1 s - Testing
Bits 208 to 223 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 1996 to 2014.
Misfire count #5, variant 1 ACURA_MIS_CNT_5_VAR_1_PCM
- Request
22 26 6C - Service 22
DID 266C - Module
DA0E → 0E - Every
1 s - Testing
Bits 80 to 87 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1996 to 2014.
Misfire count #5, variant 1 ACURA_MISFIRE_COUNT_5_VAR_1
- Request
22 26 6C - Service 22
DID 266C - Module
DA11 → 11 - Every
1 s - Testing
Bits 80 to 87 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1996 to 2014.
Misfire count #5, variant 2 ACURA_MISFIRE_COUNT_5_VAR_2
- Request
22 26 63 - Service 22
DID 2663 - Module
DA11 → 11 - Every
1 s - Testing
Bits 336 to 351 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 1996 to 2014.
Misfire count #5, variant 3 ACURA_MIS_CNT_5_VAR_3_PCM
- Request
22 26 63 - Service 22
DID 2663 - Module
DA0E → 0E - Every
1 s - Testing
Bits 224 to 239 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 1996 to 2014.
Misfire count #5, variant 3 ACURA_MISFIRE_COUNT_5_VAR_3
- Request
22 26 63 - Service 22
DID 2663 - Module
DA11 → 11 - Every
1 s - Testing
Bits 224 to 239 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 1996 to 2014.
Misfire count #6, variant 1 ACURA_MIS_CNT_6_VAR_1_PCM
- Request
22 26 6C - Service 22
DID 266C - Module
DA0E → 0E - Every
1 s - Testing
Bits 88 to 95 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1996 to 2014.
Misfire count #6, variant 1 ACURA_MISFIRE_COUNT_6_VAR_1
- Request
22 26 6C - Service 22
DID 266C - Module
DA11 → 11 - Every
1 s - Testing
Bits 88 to 95 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1996 to 2014.
Misfire count #6, variant 2 ACURA_MISFIRE_COUNT_6_VAR_2
- Request
22 26 63 - Service 22
DID 2663 - Module
DA11 → 11 - Every
1 s - Testing
Bits 352 to 367 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 1996 to 2014.
Misfire count #6, variant 3 ACURA_MIS_CNT_6_VAR_3_PCM
- Request
22 26 63 - Service 22
DID 2663 - Module
DA0E → 0E - Every
1 s - Testing
Bits 240 to 255 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 1996 to 2014.
Misfire count #6, variant 3 ACURA_MISFIRE_COUNT_6_VAR_3
- Request
22 26 63 - Service 22
DID 2663 - Module
DA11 → 11 - Every
1 s - Testing
Bits 240 to 255 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 1996 to 2014.
Misfire count 1 ACURA_MIS_CNT_1
- Request
22 26 63 - Service 22
DID 2663 - Module
DA1D → 1D - Every
1 s - Testing
Bits 272 to 287 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 1996 to 2014.
Misfire count 2 ACURA_MIS_CNT_2
- Request
22 26 63 - Service 22
DID 2663 - Module
DA1D → 1D - Every
1 s - Testing
Bits 288 to 303 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 1996 to 2014.
Misfire count 3 ACURA_MIS_CNT_3
- Request
22 26 63 - Service 22
DID 2663 - Module
DA1D → 1D - Every
1 s - Testing
Bits 304 to 319 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 1996 to 2014.
Misfire count 4 ACURA_MIS_CNT_4
- Request
22 26 63 - Service 22
DID 2663 - Module
DA1D → 1D - Every
1 s - Testing
Bits 320 to 335 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 1996 to 2014.
Misfire count, cylinder 1 ACURA_MIS_1
- Request
22 26 63 - Service 22
DID 2663 - Module
DA10 → 10 - Every
1 s - Testing
Bits 272 to 287 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 1996 to 2014.
Misfire count, cylinder 2 ACURA_MIS_2
- Request
22 26 63 - Service 22
DID 2663 - Module
DA10 → 10 - Every
1 s - Testing
Bits 288 to 303 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 1996 to 2014.
Misfire count, cylinder 3 ACURA_MIS_3
- Request
22 26 63 - Service 22
DID 2663 - Module
DA10 → 10 - Every
1 s - Testing
Bits 304 to 319 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 1996 to 2014.
Misfire count, cylinder 4 ACURA_MIS_4
- Request
22 26 63 - Service 22
DID 2663 - Module
DA10 → 10 - Every
1 s - Testing
Bits 320 to 335 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 1996 to 2014.
Motor inverter, current ACURA_MOTOR_INVERTER_CURRENT
- Request
22 20 01 - Service 22
DID 2001 - Module
DBEF - Every
5 s - Testing
Bits 48 to 63 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -327.68 to 327.67 A
- Unit
- A
In testing for 1996 to 2014.
Outside air temperature ACURA_OUTSIDE_AIR_TEMPERATURE
- Request
22 20 01 - Service 22
DID 2001 - Module
DBEF - Every
5 s - Testing
Bits 208 to 215 of the reply, 8 bits.
- Formula
(val × 1.8 + 32)- Range
- 0 to 491 °F
- Unit
- °F
In testing for 1996 to 2014.
Transmission fluid temperature ACURA_ATF_T_NEW
- Request
22 22 01 - Service 22
DID 2201 - Module
DA1D → 1D - Every
1 s - Testing
Bits 208 to 215 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 1996 to 2006, 2008 to 2011, 2013 to 2014. Not supported for 2007, 2012.
Transmission fluid temperature, variant 4 ACURA_ATF_T_VAR_4
Pelican can show this parameter as the transmission fluid temperature.
- Request
22 22 01 - Service 22
DID 2201 - Module
DA1E → 1E - Every
5 s - Testing
Bits 208 to 215 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 1996 to 2014.
Variable timing control duty ACURA_VARIABLE_TIM_CTRL
- Request
22 26 62 - Service 22
DID 2662 - Module
DA11 → 11 - Every
5 s - Testing
Bits 224 to 231 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 1996 to 2014.
Variable timing control duty ACURA_VTC_DUTY_DA11
- Request
22 26 62 - Service 22
DID 2662 - Module
DA11 → 11 - Every
5 s - Testing
Bits 224 to 231 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
In testing for 1996 to 2014.
Variable valve timing duty ACURA_VTC_DUTY
- Request
22 26 62 - Service 22
DID 2662 - Module
DA10 → 10 - Every
250 ms - Testing
Bits 224 to 231 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
In testing for 1996 to 2006, 2008 to 2011, 2013 to 2014. Not supported for 2007, 2012.
Variable valve timing duty ACURA_VTC_DUTY_PCM
- Request
22 26 62 - Service 22
DID 2662 - Module
DA0E → 0E - Every
1 s - Testing
Bits 224 to 231 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
In testing for 1996 to 2014.
VTEC valve control ACURA_VTEC_VALVE_CTRL
VTEC works by switching between two (or sometimes three) different camshaft profiles by engaging or disengaging a mechanism that locks the valve rocker arms together. When VTEC is OFF, the engine operates using the standard cam profile, which is typically optimized for fuel efficiency and low-end torque. When VTEC is ON, the system switches to a high-performance cam profile that allows the valves to open wider and for a longer duration, enabling better airflow at higher RPMs for increased power.
- Request
22 26 12 - Service 22
DID 2612 - Module
DA11 → 11 - Every
1 s - Testing
Bit 175 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 1996 to 2006, 2008 to 2011, 2013 to 2014. Not supported for 2007, 2012.
VTEC valve control ACURA_VTEC_VALVE_CTRL_PCM
VTEC works by switching between two (or sometimes three) different camshaft profiles by engaging or disengaging a mechanism that locks the valve rocker arms together. When VTEC is OFF, the engine operates using the standard cam profile, which is typically optimized for fuel efficiency and low-end torque. When VTEC is ON, the system switches to a high-performance cam profile that allows the valves to open wider and for a longer duration, enabling better airflow at higher RPMs for increased power.
- Request
22 26 12 - Service 22
DID 2612 - Module
DA0E → 0E - Every
250 ms - Testing
Bit 175 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 1996 to 2014.
Engine › OxygenSensors
Lambda value, Equivalence Ratio Bank 1, Sensor 1 LAMBDA11_CURRENTSAE J1979Confirmed
Pelican can show this parameter as the O2 lambda.
- Request
01 34 - Service 01
PID 34 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 32768)- Range
- 0 to 1.99
- Unit
- Number
Confirmed for 2012.
Wide Range O2S Current, O2 Sensor Bank 1, Sensor 1 O2S11_CURRENTSAE J1979Confirmed
- Request
01 34 - Service 01
PID 34 - Module
7E0 → 7E8 - Every
250 ms
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val ÷ 256 − 128)- Range
- -128 to 127.996 mA
- Unit
- mA
Confirmed for 2012.