ECU parameters
The Acura TL has 12 ECU parameters.
● Confirmed◆ In testing○ Supported× Not supported
Knock control ACURA_KNOCK_CTRL
- Request
22 26 62 - Service 22
DID 2662 - Module
DA10 → 10 - Every
250 ms - Testing
Bits 80 to 87 of the reply, 8 bits.
- Formula
(val × 2 ÷ 255)- Range
- 0 to 2
- Unit
- Number
In testing for 1996 to 2006, 2008 to 2011, 2013 to 2014. Not supported for 2007, 2012.
Knock control ACURA_KNOCK_CTRL_PCM
- Request
22 26 62 - Service 22
DID 2662 - Module
DA0E → 0E - Every
1 s - Testing
Bits 80 to 87 of the reply, 8 bits.
- Formula
(val × 2 ÷ 255)- Range
- 0 to 2
- Unit
- Number
In testing for 1996 to 2014.
Misfire count, cylinder 1 ACURA_MIS_1_PCM
- Request
22 26 63 - Service 22
DID 2663 - Module
DA0E → 0E - Every
1 s - Testing
Bits 272 to 287 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 1996 to 2014.
Misfire count, cylinder 2 ACURA_MIS_2_PCM
- Request
22 26 63 - Service 22
DID 2663 - Module
DA0E → 0E - Every
1 s - Testing
Bits 288 to 303 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 1996 to 2014.
Misfire count, cylinder 3 ACURA_MIS_3_PCM
- Request
22 26 63 - Service 22
DID 2663 - Module
DA0E → 0E - Every
1 s - Testing
Bits 304 to 319 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 1996 to 2014.
Misfire count, cylinder 4 ACURA_MIS_4_PCM
- Request
22 26 63 - Service 22
DID 2663 - Module
DA0E → 0E - Every
1 s - Testing
Bits 320 to 335 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 1996 to 2014.
Misfire count, cylinder 5 ACURA_MIS_5_PCM
- Request
22 26 63 - Service 22
DID 2663 - Module
DA0E → 0E - Every
1 s - Testing
Bits 336 to 351 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 1996 to 2014.
Misfire count, cylinder 5 ACURA_MISFIRE_5
- Request
22 26 63 - Service 22
DID 2663 - Module
DA10 → 10 - Every
1 s - Testing
Bits 336 to 351 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 1996 to 2006, 2008 to 2011, 2013 to 2014. Not supported for 2007, 2012.
Misfire count, cylinder 6 ACURA_MIS_6_PCM
- Request
22 26 63 - Service 22
DID 2663 - Module
DA0E → 0E - Every
1 s - Testing
Bits 352 to 367 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 1996 to 2014.
Misfire count, cylinder 6 ACURA_MISFIRE_6
- Request
22 26 63 - Service 22
DID 2663 - Module
DA10 → 10 - Every
1 s - Testing
Bits 352 to 367 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 1996 to 2006, 2008 to 2011, 2013 to 2014. Not supported for 2007, 2012.
Oil pressure ACURA_EOP
- Request
22 22 03 - Service 22
DID 2203 - Module
DA1D → 1D - Every
1 s - Testing
Bits 72 to 79 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 kPa
- Unit
- kPa
In testing for 1996 to 2006, 2008 to 2011, 2013 to 2014. Not supported for 2007, 2012.
Variable valve control ACURA_VTEC_CTRL
- Request
22 26 12 - Service 22
DID 2612 - Module
DA10 → 10 - Every
250 ms - Testing
Bits 168 to 175 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1996 to 2006, 2008 to 2011, 2013 to 2014. Not supported for 2007, 2012.