Volvo S60

Transmission parameters

The Volvo S60 has 6 transmission parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

Clutch pump duty S60_CLU_PMP_DUTY

  • Request22 D9 20
  • Service 22DID D920
  • ModuleD016 → 1EC70E80
  • Every1 s
  • Testing for 2000 to 2019, 2021 to 2024

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2000 to 2014, 2016 to 2019, 2021 to 2024. Supported for 2020. Not supported for 2015.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Clutch pump duty S60_CLU_PMP_DUTY

  • Request22 D9 20
  • Service 22DID D920
  • ModuleD016 → 1EC70E80
  • Every1 s
  • Testing for 2000 to 2019, 2021 to 2024

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2000 to 2014, 2016 to 2019, 2021 to 2024. Supported for 2020. Not supported for 2015.

Gear S60_GEAR

  • Request22 DA 85
  • Service 22DID DA85
  • ModuleD016 → 1EC64E80
  • Every250 ms
  • Testing for 2000 to 2019, 2021 to 2024

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2000 to 2014, 2016 to 2019, 2021 to 2024. Supported for 2020. Not supported for 2015.

Gear ratio, actual S60_GEAR_RAT_ACT

  • Request22 DA 34
  • Service 22DID DA34
  • ModuleD016 → 1EC64E80
  • Every250 ms
  • Testing for 2000 to 2019, 2021 to 2024

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 61 ÷ 250000)
Range
0 to 15.99
Unit
Number

In testing for 2000 to 2014, 2016 to 2019, 2021 to 2024. Supported for 2020. Not supported for 2015.

Gear ratio, requested S60_GEAR_RAT_REQ

  • Request22 DA 47
  • Service 22DID DA47
  • ModuleD016 → 1EC64E80
  • Every250 ms
  • Testing for 2000 to 2019, 2021 to 2024

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.53
Unit
Number

In testing for 2000 to 2014, 2016 to 2019, 2021 to 2024. Supported for 2020. Not supported for 2015.

Torque converter lock S60_TQ_CONV_LOCK

  • Request22 DA 3C
  • Service 22DID DA3C
  • ModuleD016 → 1EC64E80
  • Every250 ms
  • Testing for 2000 to 2019, 2021 to 2024

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2000 to 2014, 2016 to 2019, 2021 to 2024. Supported for 2020. Not supported for 2015.

Transmission fluid temperature S60_ATF_T

Pelican can show this parameter as the transmission fluid temperature.

  • Request22 DA 3B
  • Service 22DID DA3B
  • ModuleD016 → 1EC64E80
  • Every5 s
  • Testing for 2000 to 2019, 2021 to 2024

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 °C
Unit
°C

In testing for 2000 to 2014, 2016 to 2019, 2021 to 2024. Supported for 2020. Not supported for 2015.

Keyboard shortcuts

jk/↓↑
Move down or up through a list or a grid.
hl/←→
Move across a row or between cards.
Enter
Open the focused link.
f
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.