Volvo S60

Battery parameters

The Volvo S60 has 36 battery parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

Auxiliary battery current S60_AUXILIARY_BAT

  • Request22 41 12
  • Service 22DID 4112
  • ModuleD01A → 1F402E80
  • Every1 s
  • Testing for 2000 to 2019, 2021 to 2024

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 127)
Range
-127 to 128 A
Unit
A

In testing for 2000 to 2014, 2016 to 2019, 2021 to 2024. Supported for 2020. Not supported for 2015.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Auxiliary battery current S60_AUXILIARY_BAT

  • Request22 41 12
  • Service 22DID 4112
  • ModuleD01A → 1F402E80
  • Every1 s
  • Testing for 2000 to 2019, 2021 to 2024

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 127)
Range
-127 to 128 A
Unit
A

In testing for 2000 to 2014, 2016 to 2019, 2021 to 2024. Supported for 2020. Not supported for 2015.

Auxiliary battery temperature S60_AUXILIARY_BAT_T

  • Request22 40 D3
  • Service 22DID 40D3
  • ModuleD01A → 1F402E80
  • Every5 s
  • Testing for 2000 to 2019, 2021 to 2024

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 50)
Range
-50 to 205 °C
Unit
°C

In testing for 2000 to 2014, 2016 to 2019, 2021 to 2024. Supported for 2020. Not supported for 2015.

Auxiliary battery voltage S60_AUXILIARY_BAT_V

  • Request22 41 7E
  • Service 22DID 417E
  • ModuleD01A → 1F402E80
  • Every5 s
  • Testing for 2000 to 2019, 2021 to 2024

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 10)
Range
0 to 25.5 V
Unit
V

In testing for 2000 to 2014, 2016 to 2019, 2021 to 2024. Supported for 2020. Not supported for 2015.

Average static low range battery current S60_AVG_STATIC_LOW_RANGE

  • Request22 40 25
  • Service 22DID 4025
  • ModuleD01A → 1F402E80
  • Every1 s
  • Testing for 2000 to 2019, 2021 to 2024

Bits 0 to 15 of the reply, 16 bits.

Formula
(val − 511)
Range
-511 to 65024 mA
Unit
mA

In testing for 2000 to 2014, 2016 to 2019, 2021 to 2024. Supported for 2020. Not supported for 2015.

Battery current S60_BAT_CURRENT

  • Request22 40 90
  • Service 22DID 4090
  • ModuleD01A → 1F402E80
  • Every1 s
  • Testing for 2000 to 2019, 2021 to 2024

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 16 − 512)
Range
-512 to 3583 A
Unit
A

In testing for 2000 to 2014, 2016 to 2019, 2021 to 2024. Supported for 2020. Not supported for 2015.

Battery state of charge S60_BAT_ST_CHG

  • Request22 40 28
  • Service 22DID 4028
  • ModuleD01A → 1F402E80
  • Every1 s
  • Testing for 2000 to 2019, 2021 to 2024

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 6553 %
Unit
%

In testing for 2000 to 2014, 2016 to 2019, 2021 to 2024. Supported for 2020. Not supported for 2015.

Battery voltage S60_BAT_V

Pelican can show this parameter as the starter battery voltage.

  • Request22 40 CD
  • Service 22DID 40CD
  • ModuleD01A → 1F402E80
  • Every5 s
  • Testing for 2000 to 2019, 2021 to 2024

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 40 + 5)
Range
0 to 1643 V
Unit
V

In testing for 2000 to 2014, 2016 to 2019, 2021 to 2024. Supported for 2020. Not supported for 2015.

Charger cable current S60_CHARGER_CABLE

  • Request22 EE 8D
  • Service 22DID EE8D
  • ModuleD016 → 1EC68E80
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10 − 410)
Range
-410 to 6143 A
Unit
A

In testing for 2000 to 2014, 2016 to 2019, 2021 to 2024. Not supported for 2015, 2020.

Charging socket lock S60_CHG_SOCKET_LOCKED

  • Request22 EE 8C
  • Service 22DID EE8C
  • ModuleD016 → 1EC68E80
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
1UNLOCKEDUnlocked
2LOCKEDLocked

In testing for 2000 to 2014, 2016 to 2019, 2021 to 2024. Not supported for 2015, 2020.

Control module voltage VPWRSAE J1979Confirmed

Power input to the OBD control module. VPWR is normally battery voltage, less any voltage drop in the circuit between the battery and the control module.

Pelican can show this parameter as the starter battery voltage.

  • Request01 42
  • Service 01PID 42
  • Module7E0 → 7E8
  • Every10 s

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65535 V
Unit
V

Confirmed for 2011, 2015, 2022. Supported for 2014, 2019 to 2020, 2023 to 2024.

DC charger current S60_DC_CHARGER_CURRENT

  • Request22 EE 16
  • Service 22DID EE16
  • ModuleD016 → 1EC68E80
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 655 A
Unit
A

In testing for 2000 to 2014, 2016 to 2019, 2021 to 2024. Not supported for 2015, 2020.

DC charger voltage S60_DC_CHARGER_V

  • Request22 EE 17
  • Service 22DID EE17
  • ModuleD016 → 1EC68E80
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 6553 V
Unit
V

In testing for 2000 to 2014, 2016 to 2019, 2021 to 2024. Not supported for 2015, 2020.

Enhanced Hybrid/EV Vehicle Charging State EHEV_MODESAE J1979Confirmed

  • Request01 9A
  • Service 01PID 9A
  • Module7E0 → 7E8
  • Every250 ms

Bits 1 to 2 of the reply, 2 bits.

Unit
Named states
States
Raw valueStateMeaning
0CSMCharge sustaining mode
1CDMCharge depleting mode
2CIMCharge increasing mode

Confirmed for 2022.

High voltage battery current S60_HVBAT_CURRENT

Pelican can show this parameter as the traction battery current.

  • Request22 48 02
  • Service 22DID 4802
  • ModuleD016 → 1EC6AE80
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 50)
Range
-655 to 655 A
Unit
A

In testing for 2000 to 2014, 2016 to 2019, 2021 to 2024. Not supported for 2015, 2020.

High voltage battery state of charge S60_HVBAT_ST_CHG

Pelican can show this parameter as the state of charge.

  • Request22 48 01
  • Service 22DID 4801
  • ModuleD016 → 1EC6AE80
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 500)
Range
0 to 131 %
Unit
%

In testing for 2000 to 2014, 2016 to 2019, 2021 to 2024. Not supported for 2015, 2020.

High voltage battery voltage S60_HVBAT_V

Pelican can show this parameter as the traction battery voltage.

  • Request22 48 03
  • Service 22DID 4803
  • ModuleD016 → 1EC6AE80
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 655 V
Unit
V

In testing for 2000 to 2014, 2016 to 2019, 2021 to 2024. Not supported for 2015, 2020.

High voltage battery, average temperature S60_HVBAT_AVG_T

  • Request22 49 1B
  • Service 22DID 491B
  • ModuleD016 → 1EC6AE80
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100 − 50)
Range
-50 to 605 °C
Unit
°C

In testing for 2000 to 2014, 2016 to 2019, 2021 to 2024. Not supported for 2015, 2020.

High voltage battery, coolant pump speed, actual S60_HVBAT_CLT_PMP_SPD_ACT

  • Request22 48 67
  • Service 22DID 4867
  • ModuleD016 → 1EC6AE80
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 24)
Range
0 to 6120 rpm
Unit
rpm

In testing for 2000 to 2014, 2016 to 2019, 2021 to 2024. Not supported for 2015, 2020.

High voltage battery, coolant pump speed, requested S60_HVBAT_CLT_PMP_SPD

  • Request22 48 66
  • Service 22DID 4866
  • ModuleD016 → 1EC6AE80
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 24)
Range
0 to 6120 rpm
Unit
rpm

In testing for 2000 to 2014, 2016 to 2019, 2021 to 2024. Not supported for 2015, 2020.

High voltage battery, high-voltage coolant heater fuse voltage S60_HVBAT_HVCH_FUSE_V

  • Request22 48 0A
  • Service 22DID 480A
  • ModuleD016 → 1EC6AE80
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 655 V
Unit
V

In testing for 2000 to 2014, 2016 to 2019, 2021 to 2024. Not supported for 2015, 2020.

High voltage battery, IEM fuse voltage S60_HVBAT_IEM_FUSE_V

  • Request22 48 08
  • Service 22DID 4808
  • ModuleD016 → 1EC6AE80
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 655 V
Unit
V

In testing for 2000 to 2014, 2016 to 2019, 2021 to 2024. Not supported for 2015, 2020.

High voltage battery, IGM fuse voltage S60_HVBAT_IGM_FUSE_V

  • Request22 48 09
  • Service 22DID 4809
  • ModuleD016 → 1EC6AE80
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 655 V
Unit
V

In testing for 2000 to 2014, 2016 to 2019, 2021 to 2024. Not supported for 2015, 2020.

High voltage battery, inlet coolant temperature S60_HVBAT_INLET_ECT

  • Request22 48 04
  • Service 22DID 4804
  • ModuleD016 → 1EC6AE80
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 50)
Range
-50 to 205 °C
Unit
°C

In testing for 2000 to 2014, 2016 to 2019, 2021 to 2024. Not supported for 2015, 2020.

High voltage battery, max temperature S60_HVBAT_MAX_T

  • Request22 49 45
  • Service 22DID 4945
  • ModuleD016 → 1EC6AE80
  • Every1 s
  • Testing

Bits 8 to 23 of the reply, 16 bits.

Formula
(val ÷ 100 − 50)
Range
-50 to 605 °C
Unit
°C

In testing for 2000 to 2014, 2016 to 2019, 2021 to 2024. Not supported for 2015, 2020.

High voltage battery, OBC fuse voltage S60_HVBAT_OBC_FUSE_V

  • Request22 48 0B
  • Service 22DID 480B
  • ModuleD016 → 1EC6AE80
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 655 V
Unit
V

In testing for 2000 to 2014, 2016 to 2019, 2021 to 2024. Not supported for 2015, 2020.

Hybrid battery pack remaining charge BAT_SOCSAE J1979Confirmed

The percent remaining level of charge for a battery pack used for propulsion, expressed as a percentage of total useable battery energy, commonly referred to as State Of Charge (SOC).

Pelican can show this parameter as the state of charge.

  • Request01 5B
  • Service 01PID 5B
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

Confirmed for 2020, 2022 to 2024.

Hybrid/EV Battery System Current HEV_BATT_ASAE J1979Confirmed

  • Request01 9A
  • Service 01PID 9A
  • Module7E0 → 7E8
  • Every250 ms

Bits 32 to 47 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-3276.8 to 3276.7 A
Unit
A

Confirmed for 2022.

Hybrid/EV Battery System Voltage HEV_BATT_VSAE J1979Confirmed

  • Request01 9A
  • Service 01PID 9A
  • Module7E0 → 7E8
  • Every250 ms

Bits 16 to 31 of the reply, 16 bits.

Formula
(val ÷ 64)
Range
0 to 1023.98 V
Unit
V

Confirmed for 2022.

Hybrid/EV Vehicle Charging State HEV_MODESAE J1979Confirmed

  • Request01 9A
  • Service 01PID 9A
  • Module7E0 → 7E8
  • Every250 ms

Bit 0 of the reply.

Unit
Named states
States
Raw valueStateMeaning
0CSMCharge sustaining mode
1CDMCharge depleting mode

Confirmed for 2022.

Main charger current S60_MAIN_CHARGER_CURRENT

  • Request22 EE 15
  • Service 22DID EE15
  • ModuleD016 → 1EC68E80
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 6553 A
Unit
A

In testing for 2000 to 2014, 2016 to 2019, 2021 to 2024. Not supported for 2015, 2020.

Main charger voltage S60_MAIN_CHARGER_V

  • Request22 EE 1C
  • Service 22DID EE1C
  • ModuleD016 → 1EC68E80
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 V
Unit
V

In testing for 2000 to 2014, 2016 to 2019, 2021 to 2024. Not supported for 2015, 2020.

Module voltage S60_MODULE_V

  • Request22 D1 11
  • Service 22DID D111
  • ModuleD016 → 1EC70E80
  • Every5 s
  • Testing for 2000 to 2019, 2021 to 2024

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 10)
Range
0 to 25.5 V
Unit
V

In testing for 2000 to 2014, 2016 to 2019, 2021 to 2024. Supported for 2020. Not supported for 2015.

Battery › Internal

Enhanced Hybrid/EV Vehicle Charging State supported? EHEV_MODE_SUPSAE J1979Confirmed

  • Request01 9A
  • Service 01PID 9A
  • Module7E0 → 7E8
  • Every250 ms

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2022.

Hybrid/EV Battery Current supported? HEV_BATT_A_SUPSAE J1979Confirmed

  • Request01 9A
  • Service 01PID 9A
  • Module7E0 → 7E8
  • Every250 ms

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2022.

Hybrid/EV Battery Voltage supported? HEV_BATT_V_SUPSAE J1979Confirmed

  • Request01 9A
  • Service 01PID 9A
  • Module7E0 → 7E8
  • Every250 ms

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2022.

Hybrid/EV Vehicle Charging State supported? HEV_MODE_SUPSAE J1979Confirmed

  • Request01 9A
  • Service 01PID 9A
  • Module7E0 → 7E8
  • Every250 ms

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2022.

Keyboard shortcuts

jk/↓↑
Move down or up through a list or a grid.
hl/←→
Move across a row or between cards.
Enter
Open the focused link.
f
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.