Toyota RAV4 Prime

Light parameters

The Toyota RAV4 Prime has 5 light parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

Check engine SW RAV4PRIME_CHECK_ENGINE_LIGHT

  • Request21 12
  • Service 21PID 12
  • Module7C0 → 7C8
  • Every1 s
  • Testing

Bit 15 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2020, 2022 to 2026. Not supported for 2021.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Check engine SW RAV4PRIME_CHECK_ENGINE_LIGHT

  • Request21 12
  • Service 21PID 12
  • Module7C0 → 7C8
  • Every1 s
  • Testing

Bit 15 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2020, 2022 to 2026. Not supported for 2021.

Oil pressure switch RAV4PRIME_EOP_LIGHT

  • Request21 12
  • Service 21PID 12
  • Module7C0 → 7C8
  • Every1 s
  • Testing

Bit 35 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2020, 2022 to 2026. Not supported for 2021.

P-seatbelt buckle SW RAV4PRIME_P_SEATBELT_BUCKLE_LIGHT

  • Request21 12
  • Service 21PID 12
  • Module7C0 → 7C8
  • Every1 s
  • Testing

Bit 8 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2020, 2022 to 2026. Not supported for 2021.

Rheostat RAV4PRIME_RHEOSTAT

Higher values are brighter

  • Request21 68
  • Service 21PID 68
  • Module7C0 → 7C8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2020, 2022 to 2026. Not supported for 2021.

Tail cancel SW RAV4PRIME_TAIL_CANCEL_LIGHT

  • Request21 12
  • Service 21PID 12
  • Module7C0 → 7C8
  • Every1 s
  • Testing

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2020, 2022 to 2026. Not supported for 2021.

Keyboard shortcuts

jk/↓↑
Move down or up through a list or a grid.
hl/←→
Move across a row or between cards.
Enter
Open the focused link.
f
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.