Transmission parameters
The Toyota Prius has 32 transmission parameters.
● Confirmed◆ In testing○ Supported× Not supported
Boosting converter temperature, lower PRIUS_BOOSTING_CONV_T_LOConfirmed
- Request
22 10 A7 - Service 22
DID 10A7 - Module
7D2 → 7DA - Every
5 s - Testing for 2017 to 2023, 2026
Example reply from a 2025 Toyota Prius.
Bits 8 to 15 of the reply, 8 bits.
0x43 = 67 → (67 − 40) = 27 °C
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2016, 2024 to 2025. In testing for 2017 to 2023, 2026.
Boosting converter temperature, upper PRIUS_BOOSTING_CONV_T_HIConfirmed
- Request
22 10 A7 - Service 22
DID 10A7 - Module
7D2 → 7DA - Every
5 s - Testing for 2017 to 2023, 2026
Example reply from a 2025 Toyota Prius.
Bits 0 to 7 of the reply, 8 bits.
0x43 = 67 → (67 − 40) = 27 °C
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2016, 2024 to 2025. In testing for 2017 to 2023, 2026.
Current gear PRIUS_GEAR_V2
- Request
21 DA - Service 21
PID DA - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1997 to 2008, 2010 to 2012, 2014 to 2015, 2017 to 2023, 2026. Not supported for 2009, 2013, 2016, 2024 to 2025.
DC-DC converter output current PRIUS_DC_DC_CONV_OUTPUTConfirmed
- Request
22 11 1C - Service 22
DID 111C - Module
7D2 → 7DA - Every
1 s - Testing for 1997 to 2023, 2026
Example reply from a 2025 Toyota Prius.
Bits 0 to 7 of the reply, 8 bits.
0x00 = 0 → (0 × 25 ÷ 32) = 0 A
- Formula
(val × 25 ÷ 32)- Range
- 0 to 199 A
- Unit
- A
Confirmed for 2024 to 2025. In testing for 2017 to 2023, 2026. Not supported for 2016.
Gear PRIUS_GEAR
- Request
21 85 - Service 21
PID 85 - Module
7E0 → 7E8 - Every
400 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 20
- Unit
- Number
In testing for 1997 to 2004, 2006, 2015, 2017 to 2018, 2020 to 2021, 2023, 2026. Not supported for 2005, 2007 to 2014, 2016, 2019, 2022, 2024 to 2025.
Gear PRIUS_GEAR_700
- Request
22 16 21 - Service 22
DID 1621 - Module
700 → 708 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1997 to 2008, 2010 to 2012, 2014 to 2015, 2017 to 2023, 2026. Not supported for 2009, 2013, 2016, 2024 to 2025.
Lock up state PRIUS_AT_LOCK_UP_STATE
- Request
22 16 20 - Service 22
DID 1620 - Module
700 → 708 - Every
1 s - Testing
Bit 7 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 1997 to 2008, 2010 to 2012, 2014 to 2015, 2017 to 2023, 2026. Not supported for 2009, 2013, 2016, 2024 to 2025.
Shift in drive PRIUS_SHIFT_DConfirmed
- Request
21 D3 - Service 21
PID D3 - Module
7E2 → 7EA - Every
1 s - Testing for 1997 to 2008
Example reply from a 2009 Toyota Prius.
Bit 16 of the reply.
0b0 = 0 → 0
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
Confirmed for 2009. In testing for 2004 to 2008.
Shift position sensor voltage PRIUS_SHIFT_POS_VConfirmed
- Request
21 C3 - Service 21
PID C3 - Module
7E2 → 7EA - Every
250 ms - Testing for 1997 to 2008
Bits 280 to 287 of the reply, 8 bits.
- Formula
(val ÷ 51)- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2009. In testing for 2004 to 2008.
Shift select sensor main voltage PRIUS_SELECT_MAIN_VConfirmed
- Request
21 C3 - Service 21
PID C3 - Module
7E2 → 7EA - Every
250 ms - Testing for 1997 to 2008
Bits 264 to 271 of the reply, 8 bits.
- Formula
(val ÷ 51)- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2009. In testing for 2004 to 2008.
Shift select sensor sub voltage PRIUS_SELECT_SUB_VConfirmed
- Request
21 C3 - Service 21
PID C3 - Module
7E2 → 7EA - Every
250 ms - Testing for 1997 to 2008
Bits 272 to 279 of the reply, 8 bits.
- Formula
(val ÷ 51)- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2009. In testing for 2004 to 2008.
Shift sensor main voltage PRIUS_SHIFT_MAIN_VConfirmed
- Request
21 C3 - Service 21
PID C3 - Module
7E2 → 7EA - Every
250 ms - Testing for 1997 to 2008
Example reply from a 2009 Toyota Prius.
Bits 248 to 255 of the reply, 8 bits.
0x7D = 125 → (125 ÷ 51) = 2.45098 V
- Formula
(val ÷ 51)- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2009. In testing for 2004 to 2008.
Shift sensor sub voltage PRIUS_SHIFT_SUB_VConfirmed
- Request
21 C3 - Service 21
PID C3 - Module
7E2 → 7EA - Every
250 ms - Testing for 1997 to 2008
Example reply from a 2009 Toyota Prius.
Bits 256 to 263 of the reply, 8 bits.
0x7D = 125 → (125 ÷ 51) = 2.45098 V
- Formula
(val ÷ 51)- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2009. In testing for 2004 to 2008.
Torque converter and TE1 on PRIUS_TQ_CONV_TE1_ON
- Request
21 39 - Service 21
PID 39 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bit 30 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1997 to 2008, 2010 to 2012, 2014 to 2015, 2017 to 2023, 2026. Not supported for 2009, 2013, 2016, 2024 to 2025.
Torque converter lock-up PRIUS_TQC_LOCKUP
Engages a clutch inside the torque converter to create a direct connection between the engine and transmission, reducing slippage and improving efficiency.
- Request
21 85 - Service 21
PID 85 - Module
7E0 → 7E8 - Every
400 ms - Testing
Bit 8 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 1997 to 2004, 2006, 2015, 2017 to 2018, 2020 to 2021, 2023, 2026. Not supported for 2005, 2007 to 2014, 2016, 2019, 2022, 2024 to 2025.
Transmission fluid post-converter temperature, variant 3 PRIUS_TRANS_FLUID_POST_T_3
- Request
22 16 28 - Service 22
DID 1628 - Module
700 → 708 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 256 − 40)- Range
- -40 to 215.996 °C
- Unit
- °C
In testing for 1997 to 2008, 2010 to 2012, 2014 to 2015, 2017 to 2023, 2026. Not supported for 2009, 2013, 2016, 2024 to 2025.
Transmission fluid temperature, pan var.3 PRIUS_ATF_T_PAN_V3
Pelican can show this parameter as the transmission fluid temperature.
- Request
22 16 27 - Service 22
DID 1627 - Module
700 → 708 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 256 − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 1997 to 2008, 2010 to 2012, 2014 to 2015, 2017 to 2023, 2026. Not supported for 2009, 2013, 2016, 2024 to 2025.
Transmission fluid temperature, variant 5 PRIUS_ATF_T_V_5
- Request
21 D9 - Service 21
PID D9 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
(val ÷ 256 − 40)- Range
- -40 to 215.996 °C
- Unit
- °C
In testing for 1997 to 2008, 2010 to 2012, 2014 to 2015, 2017 to 2023, 2026. Not supported for 2009, 2013, 2016, 2024 to 2025.
Transmission fluid temperature, variant 8 PRIUS_ATF_T_V_8
- Request
21 D9 - Service 21
PID D9 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 48 to 63 of the reply, 16 bits.
- Formula
(val ÷ 256 − 40)- Range
- -40 to 215.996 °C
- Unit
- °C
In testing for 1997 to 2008, 2010 to 2012, 2014 to 2015, 2017 to 2023, 2026. Not supported for 2009, 2013, 2016, 2024 to 2025.
Transmission fluid temperature, variant 9 PRIUS_ATF_T_V_9
- Request
21 D9 - Service 21
PID D9 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
(val ÷ 256 − 40)- Range
- -40 to 215.996 °C
- Unit
- °C
In testing for 1997 to 2008, 2010 to 2012, 2014 to 2015, 2017 to 2023, 2026. Not supported for 2009, 2013, 2016, 2024 to 2025.
Transmission fluid temperature, variant 10 PRIUS_ATF_T_V_10_7E1
- Request
21 82 - Service 21
PID 82 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 256 − 40)- Range
- -40 to 215.996 °C
- Unit
- °C
In testing for 1997 to 2008, 2010 to 2012, 2014 to 2015, 2017 to 2023, 2026. Not supported for 2009, 2013, 2016, 2024 to 2025.
Transmission fluid temperature, variant 11 PRIUS_ATF_T_V_11
- Request
21 82 - Service 21
PID 82 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val ÷ 256 − 40)- Range
- -40 to 215.996 °C
- Unit
- °C
In testing for 1997 to 2008, 2010 to 2012, 2014 to 2015, 2017 to 2023, 2026. Not supported for 2009, 2013, 2016, 2024 to 2025.
Transmission fluid temperature, variant 12 PRIUS_ATF_T_V_12
- Request
21 D9 - Service 21
PID D9 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 48 to 63 of the reply, 16 bits.
- Formula
(val ÷ 256 − 40)- Range
- -40 to 215.996 °C
- Unit
- °C
In testing for 1997 to 2008, 2010 to 2012, 2014 to 2015, 2017 to 2023, 2026. Not supported for 2009, 2013, 2016, 2024 to 2025.
Transmission fluid temperature, variant 14 PRIUS_ATF_T_V_14
- Request
21 D9 - Service 21
PID D9 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 256 − 40)- Range
- -40 to 215.996 °C
- Unit
- °C
In testing for 1997 to 2008, 2010 to 2012, 2014 to 2015, 2017 to 2023, 2026. Not supported for 2009, 2013, 2016, 2024 to 2025.
Transmission fluid temperature, variant 14 PRIUS_ATF_T_V_14_7E1
- Request
21 D9 - Service 21
PID D9 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 256 − 40)- Range
- -40 to 215.996 °C
- Unit
- °C
In testing for 1997 to 2008, 2010 to 2012, 2014 to 2015, 2017 to 2023, 2026. Not supported for 2009, 2013, 2016, 2024 to 2025.
Transmission fluid temperature, variant 21 PRIUS_ATF_T_V_21
- Request
21 D9 - Service 21
PID D9 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 1997 to 2008, 2010 to 2012, 2014 to 2015, 2017 to 2023, 2026. Not supported for 2009, 2013, 2016, 2024 to 2025.
Transmission fluid temperature, variant 21 PRIUS_ATF_T_V_21_7E1
- Request
21 D9 - Service 21
PID D9 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 1997 to 2008, 2010 to 2012, 2014 to 2015, 2017 to 2023, 2026. Not supported for 2009, 2013, 2016, 2024 to 2025.
Transmission oil pressure calibration, complete PRIUS_TRANS_OIL_PRESS
- Request
21 83 - Service 21
PID 83 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bit 1 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1997 to 2008, 2010 to 2012, 2014 to 2015, 2017 to 2023, 2026. Not supported for 2009, 2013, 2016, 2024 to 2025.
Transmission shift state ratio PRIUS_TRANS_SHIFT_ST_RAT
- Request
22 16 22 - Service 22
DID 1622 - Module
700 → 708 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 5333 ÷ 21845000)- Range
- 0 to 15.999
- Unit
- Number
In testing for 1997 to 2008, 2010 to 2012, 2014 to 2015, 2017 to 2023, 2026. Not supported for 2009, 2013, 2016, 2024 to 2025.
Transmission shift state ratio PRIUS_TRANS_SHIFT_ST_RAT_701
- Request
22 16 22 - Service 22
DID 1622 - Module
701 → 709 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 5333 ÷ 21845000)- Range
- 0 to 15.999
- Unit
- Number
In testing for 1997 to 2008, 2010 to 2012, 2014 to 2015, 2017 to 2023, 2026. Not supported for 2009, 2013, 2016, 2024 to 2025.
Transmission temperature, pan PRIUS_ATF_PAN_T
- Request
21 82 - Service 21
PID 82 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 256 − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 1997 to 2000, 2002 to 2004, 2006, 2018. Not supported for 2001, 2005, 2007 to 2017, 2019 to 2026.
Transmission temperature, torque converter PRIUS_ATF_TQC_T
- Request
21 82 - Service 21
PID 82 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val ÷ 256 − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 1997 to 2000, 2002 to 2004, 2006, 2018. Not supported for 2001, 2005, 2007 to 2017, 2019 to 2026.