Toyota Corolla Hybrid

Trip parameters

The Toyota Corolla Hybrid has 3 trip parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

Odometer COROLLAHYBRID_ODO_V2_V2Confirmed

Pelican can show this parameter as the odometer.

  • Request22 01 03
  • Service 22DID 0103
  • Module7D2 → 7DA
  • Every10 s
  • Testing for 2019, 2021 to 2026

Example reply from a 2020 Toyota Corolla Hybrid.

Bits 8 to 31 of the reply, 24 bits.

0x011064 = 69732 → 69,732 km

Formula
val
Range
0 to 16777215 km
Unit
km

Confirmed for 2020. In testing for 2019, 2021 to 2026.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Odometer COROLLAHYBRID_ODO

Pelican can show this parameter as the odometer.

  • Request22 01 03
  • Service 22DID 0103
  • Module747 → 74F
  • Every10 s
  • Testing

Bits 8 to 31 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

In testing for 2019, 2021 to 2026. Not supported for 2020.

Odometer COROLLAHYBRID_ODO_V2_V2Confirmed

Pelican can show this parameter as the odometer.

  • Request22 01 03
  • Service 22DID 0103
  • Module7D2 → 7DA
  • Every10 s
  • Testing for 2019, 2021 to 2026

Example reply from a 2020 Toyota Corolla Hybrid.

Bits 8 to 31 of the reply, 24 bits.

0x011064 = 69732 → 69,732 km

Formula
val
Range
0 to 16777215 km
Unit
km

Confirmed for 2020. In testing for 2019, 2021 to 2026.

Total distance COROLLAHYBRID_TOT_DIST

  • Request22 01 03
  • Service 22DID 0103
  • Module7B1 → 7B9
  • Every30 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 150
Unit
Number

In testing for 2019, 2021 to 2026. Not supported for 2020.

Keyboard shortcuts

jk/↓↑
Move down or up through a list or a grid.
hl/←→
Move across a row or between cards.
Enter
Open the focused link.
f
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.