Toyota Corolla Hybrid

Climate parameters

The Toyota Corolla Hybrid has 13 climate parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

Adjusted ambient temperature COROLLAHYBRID_ADJUSTED_AMBIENT_TConfirmed

  • Request21 3D
  • Service 21PID 3D
  • Module7C4 → 7CC
  • Every5 s
  • Testing for 2019, 2021 to 2026

Example reply from a 2020 Toyota Corolla Hybrid.

Bits 0 to 7 of the reply, 8 bits.

0x8A = 138 → (138 × 81.6 ÷ 255 − 30.8) = 13.36 °C

Formula
(val × 81.6 ÷ 255 − 30.8)
Range
-30.8 to 50.8 °C
Unit
°C

Confirmed for 2020. In testing for 2019, 2021 to 2026.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Adjusted ambient temperature COROLLAHYBRID_ADJUSTED_AMBIENT_TConfirmed

  • Request21 3D
  • Service 21PID 3D
  • Module7C4 → 7CC
  • Every5 s
  • Testing for 2019, 2021 to 2026

Example reply from a 2020 Toyota Corolla Hybrid.

Bits 0 to 7 of the reply, 8 bits.

0x8A = 138 → (138 × 81.6 ÷ 255 − 30.8) = 13.36 °C

Formula
(val × 81.6 ÷ 255 − 30.8)
Range
-30.8 to 50.8 °C
Unit
°C

Confirmed for 2020. In testing for 2019, 2021 to 2026.

Air inlet damper actual pulse COROLLAHYBRID_AIR_INLET_DAMPER_ACTUAL_PULSEConfirmed

  • Request21 44
  • Service 21PID 44
  • Module7C4 → 7CC
  • Every1 s
  • Testing for 2019, 2021 to 2026

Example reply from a 2020 Toyota Corolla Hybrid.

Bits 8 to 15 of the reply, 8 bits.

0x80 = 128 → 128

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2020. In testing for 2019, 2021 to 2026.

Air inlet damper target pulse COROLLAHYBRID_AIR_INLET_DAMPER_TARGET_PULSEConfirmed

  • Request21 44
  • Service 21PID 44
  • Module7C4 → 7CC
  • Every1 s
  • Testing for 2019, 2021 to 2026

Example reply from a 2020 Toyota Corolla Hybrid.

Bits 0 to 7 of the reply, 8 bits.

0x80 = 128 → 128

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2020. In testing for 2019, 2021 to 2026.

Air outlet servo actual pulse, driver COROLLAHYBRID_AIR_OUTLET_SERVO_ACTU_PULSE_DConfirmed

  • Request21 43
  • Service 21PID 43
  • Module7C4 → 7CC
  • Every1 s
  • Testing for 2019, 2021 to 2026

Example reply from a 2020 Toyota Corolla Hybrid.

Bits 8 to 15 of the reply, 8 bits.

0xA9 = 169 → 169

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2020. In testing for 2019, 2021 to 2026.

Air outlet servo pulse, driver COROLLAHYBRID_AIR_OUTLET_SERVO_PULSE_DConfirmed

  • Request21 43
  • Service 21PID 43
  • Module7C4 → 7CC
  • Every1 s
  • Testing for 2019, 2021 to 2026

Example reply from a 2020 Toyota Corolla Hybrid.

Bits 0 to 7 of the reply, 8 bits.

0xA9 = 169 → 169

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2020. In testing for 2019, 2021 to 2026.

Ambient air temperature AATSAE J1979Confirmed

  • Request01 46
  • Service 01PID 46
  • Module7E0 → 7E8
  • Every15 s

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2022. Supported for 2019 to 2021, 2023 to 2026.

Ambient air temperature COROLLAHYBRID_AAT_7C4Confirmed

  • Request21 22
  • Service 21PID 22
  • Module7C4 → 7CC
  • Every5 s
  • Testing for 2019, 2021 to 2026

Example reply from a 2020 Toyota Corolla Hybrid.

Bits 0 to 7 of the reply, 8 bits.

0x69 = 105 → (105 × 89.25 ÷ 255 − 23.3) = 13.45 °C

Formula
(val × 89.25 ÷ 255 − 23.3)
Range
-23.3 to 65.95 °C
Unit
°C

Confirmed for 2020. In testing for 2019, 2021 to 2026.

Blower motor speed level COROLLAHYBRID_BLOWER_MOTOR_SPEED_LEVELConfirmed

  • Request21 3C
  • Service 21PID 3C
  • Module7C4 → 7CC
  • Every5 s
  • Testing for 2019, 2021 to 2026

Example reply from a 2020 Toyota Corolla Hybrid.

Bits 0 to 7 of the reply, 8 bits.

0x0F = 15 → 15

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2020. In testing for 2019, 2021 to 2026.

Cabin temperature COROLLAHYBRID_CABIN_TConfirmed

  • Request21 21
  • Service 21PID 21
  • Module7C4 → 7CC
  • Every5 s
  • Testing for 2019, 2021 to 2026

Example reply from a 2020 Toyota Corolla Hybrid.

Bits 0 to 7 of the reply, 8 bits.

0x6B = 107 → (107 × 63.75 ÷ 255 − 6.5) = 20.25 °C

Formula
(val × 63.75 ÷ 255 − 6.5)
Range
-6.5 to 57.25 °C
Unit
°C

Confirmed for 2020. In testing for 2019, 2021 to 2026.

Evaporator fin thermistor COROLLAHYBRID_EVAP_FIN_THERMISTORConfirmed

  • Request21 4B
  • Service 21PID 4B
  • Module7C4 → 7CC
  • Every5 s
  • Testing for 2019, 2021 to 2026

Example reply from a 2020 Toyota Corolla Hybrid.

Bits 0 to 7 of the reply, 8 bits.

0x5A = 90 → (90 × 89.25 ÷ 255 − 29.7) = 1.8 °C

Formula
(val × 89.25 ÷ 255 − 29.7)
Range
-29.7 to 59.55 °C
Unit
°C

Confirmed for 2020. In testing for 2019, 2021 to 2026.

Evaporator target temperature COROLLAHYBRID_EVAP_TARGET_TConfirmed

  • Request21 4C
  • Service 21PID 4C
  • Module7C4 → 7CC
  • Every1 s
  • Testing for 2019, 2021 to 2026

Example reply from a 2020 Toyota Corolla Hybrid.

Bits 0 to 15 of the reply, 16 bits.

0x80C8 = 32968 → (32968 ÷ 100 − 327.68) = 2

Formula
(val ÷ 100 − 327.68)
Range
-327.68 to 327.67
Unit
Number

Confirmed for 2020. In testing for 2019, 2021 to 2026.

Set temperature, driver side COROLLAHYBRID_T_DRIVER

  • Request21 29
  • Service 21PID 29
  • Module7C4 → 7CC
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 °C
Unit
°C

In testing for 2019, 2021 to 2026. Not supported for 2020.

Solar sensor, driver side COROLLAHYBRID_SOLAR_DRIVER

  • Request21 24
  • Service 21PID 24
  • Module7C4 → 7CC
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2019, 2021 to 2026. Not supported for 2020.

Keyboard shortcuts

jk/↓↑
Move down or up through a list or a grid.
hl/←→
Move across a row or between cards.
Enter
Open the focused link.
f
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.