Transmission parameters
The Toyota C-HR has 25 transmission parameters.
● Confirmed◆ In testing○ Supported× Not supported
Boosting converter temperature, lower CHR_BOOSTING_CONV_T_LO
- Request
22 10 A7 - Service 22
DID 10A7 - Module
7D2 → 7DA - Every
5 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2019 to 2026.
Boosting converter temperature, upper CHR_BOOSTING_CONV_T_HI
- Request
22 10 A7 - Service 22
DID 10A7 - Module
7D2 → 7DA - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2019 to 2026.
Current gear CHR_GEAR_V2
- Request
21 DA - Service 21
PID DA - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2019, 2024.
DC-DC converter output current CHR_DC_DC_CONV_OUTPUT
- Request
22 11 1C - Service 22
DID 111C - Module
7D2 → 7DA - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 25 ÷ 32)- Range
- 0 to 199 A
- Unit
- A
In testing for 2019 to 2026.
Gear CHR_GEARConfirmed
- Request
21 85 - Service 21
PID 85 - Module
7E0 → 7E8 - Every
400 ms - Testing for 2016 to 2018, 2020 to 2026
Example reply from a 2019 Toyota C-HR.
Bits 0 to 7 of the reply, 8 bits.
0x01 = 1 → 1
- Formula
val- Range
- 0 to 20
- Unit
- Number
Confirmed for 2019. In testing for 2016 to 2018, 2020 to 2021, 2026. Not supported for 2022 to 2025.
Gear CHR_GEAR_700
- Request
22 16 21 - Service 22
DID 1621 - Module
700 → 708 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2019, 2024.
Lock up state CHR_AT_LOCK_UP_STATE
- Request
22 16 20 - Service 22
DID 1620 - Module
700 → 708 - Every
1 s - Testing
Bit 7 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2019, 2024.
Torque converter and TE1 on CHR_TQ_CONV_TE1_ON
- Request
21 39 - Service 21
PID 39 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bit 30 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 2016 to 2026.
Torque converter lock-up CHR_TQC_LOCKUPConfirmed
Engages a clutch inside the torque converter to create a direct connection between the engine and transmission, reducing slippage and improving efficiency.
- Request
21 85 - Service 21
PID 85 - Module
7E0 → 7E8 - Every
400 ms - Testing for 2016 to 2018, 2020 to 2026
Example reply from a 2019 Toyota C-HR.
Bit 8 of the reply.
0b0 = 0 → 0
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
Confirmed for 2019. In testing for 2016 to 2018, 2020 to 2021, 2026. Not supported for 2022 to 2025.
Transmission fluid post-converter temperature, variant 3 CHR_TRANS_FLUID_POST_T_3
- Request
22 16 28 - Service 22
DID 1628 - Module
700 → 708 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 256 − 40)- Range
- -40 to 215.996 °C
- Unit
- °C
In testing for 2016 to 2026.
Transmission fluid temperature, pan var.3 CHR_ATF_T_PAN_V3
Pelican can show this parameter as the transmission fluid temperature.
- Request
22 16 27 - Service 22
DID 1627 - Module
700 → 708 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 256 − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2019, 2024.
Transmission fluid temperature, variant 5 CHR_ATF_T_V_5
- Request
21 D9 - Service 21
PID D9 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
(val ÷ 256 − 40)- Range
- -40 to 215.996 °C
- Unit
- °C
In testing for 2016 to 2026.
Transmission fluid temperature, variant 8 CHR_ATF_T_V_8
- Request
21 D9 - Service 21
PID D9 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 48 to 63 of the reply, 16 bits.
- Formula
(val ÷ 256 − 40)- Range
- -40 to 215.996 °C
- Unit
- °C
In testing for 2016 to 2026.
Transmission fluid temperature, variant 9 CHR_ATF_T_V_9
- Request
21 D9 - Service 21
PID D9 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
(val ÷ 256 − 40)- Range
- -40 to 215.996 °C
- Unit
- °C
In testing for 2016 to 2026.
Transmission fluid temperature, variant 10 CHR_ATF_T_V_10_7E1
- Request
21 82 - Service 21
PID 82 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 256 − 40)- Range
- -40 to 215.996 °C
- Unit
- °C
In testing for 2016 to 2026.
Transmission fluid temperature, variant 11 CHR_ATF_T_V_11
- Request
21 82 - Service 21
PID 82 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val ÷ 256 − 40)- Range
- -40 to 215.996 °C
- Unit
- °C
In testing for 2016 to 2026.
Transmission fluid temperature, variant 12 CHR_ATF_T_V_12
- Request
21 D9 - Service 21
PID D9 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 48 to 63 of the reply, 16 bits.
- Formula
(val ÷ 256 − 40)- Range
- -40 to 215.996 °C
- Unit
- °C
In testing for 2016 to 2026.
Transmission fluid temperature, variant 14 CHR_ATF_T_V_14
- Request
21 D9 - Service 21
PID D9 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 256 − 40)- Range
- -40 to 215.996 °C
- Unit
- °C
In testing for 2016 to 2026.
Transmission fluid temperature, variant 14 CHR_ATF_T_V_14_7E1
- Request
21 D9 - Service 21
PID D9 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 256 − 40)- Range
- -40 to 215.996 °C
- Unit
- °C
In testing for 2016 to 2026.
Transmission fluid temperature, variant 21 CHR_ATF_T_V_21
- Request
21 D9 - Service 21
PID D9 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2016 to 2026.
Transmission fluid temperature, variant 21 CHR_ATF_T_V_21_7E1
- Request
21 D9 - Service 21
PID D9 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2016 to 2026.
Transmission oil pressure calibration, complete CHR_TRANS_OIL_PRESS
- Request
21 83 - Service 21
PID 83 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bit 1 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 2016 to 2026.
Transmission shift state ratio CHR_TRANS_SHIFT_ST_RAT
- Request
22 16 22 - Service 22
DID 1622 - Module
700 → 708 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 5333 ÷ 21845000)- Range
- 0 to 15.999
- Unit
- Number
In testing for 2016 to 2026.
Transmission temperature, pan CHR_ATF_PAN_TConfirmed
Pelican can show this parameter as the transmission fluid temperature.
- Request
21 82 - Service 21
PID 82 - Module
7E0 → 7E8 - Every
1 s - Testing for 2016 to 2018, 2020 to 2026
Example reply from a 2019 Toyota C-HR.
Bits 0 to 15 of the reply, 16 bits.
0x5280 = 21120 → (21120 ÷ 256 − 40) = 42.5 °C
- Formula
(val ÷ 256 − 40)- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2019. In testing for 2016 to 2018, 2020 to 2021, 2026. Not supported for 2022 to 2025.
Transmission temperature, torque converter CHR_ATF_TQC_TConfirmed
Pelican can show this parameter as the transmission fluid temperature.
- Request
21 82 - Service 21
PID 82 - Module
7E0 → 7E8 - Every
1 s - Testing for 2016 to 2018, 2020 to 2026
Example reply from a 2019 Toyota C-HR.
Bits 16 to 31 of the reply, 16 bits.
0x8118 = 33048 → (33048 ÷ 256 − 40) = 89.09375 °C
- Formula
(val ÷ 256 − 40)- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2019. In testing for 2016 to 2018, 2020 to 2021, 2026. Not supported for 2022 to 2025.