Toyota C-HR

Engine parameters

The Toyota C-HR has 251 engine parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

Engine coolant temperature CHR_ECTConfirmed

Pelican can show this parameter as the engine coolant temperature.

  • Request21 26
  • Service 21PID 26
  • Module7C4 → 7CC
  • Every5 s
  • Testing for 2016 to 2018, 2020 to 2026

Example reply from a 2019 Toyota C-HR.

Bits 0 to 7 of the reply, 8 bits.

0x2B = 43 → (43 × 89.25 ÷ 255 + 1.3) = 16.35 °C

Formula
(val × 89.25 ÷ 255 + 1.3)
Range
1.3 to 90.55 °C
Unit
°C

Confirmed for 2019. In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2024.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

A/F heater duty bank 1 sensor 1 CHR_F_HEATER_DUTY_B1S1

  • Request21 3A
  • Service 21PID 3A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
(val × 25 ÷ 4096)
Range
0 to 399.9 %
Unit
%

In testing for 2016 to 2026.

A/F ratio learn value high, bank 1 CHR_AF_LEARN_HIGH_PORT_B1Confirmed

  • Request22 10 A2
  • Service 22DID 10A2
  • Module700 → 708
  • Every3600 s
  • Testing for 2016 to 2023, 2025 to 2026

Bits 32 to 39 of the reply, 8 bits.

Formula
(val × 100 ÷ 255 − 50)
Range
-50 to 50 %
Unit
%

Confirmed for 2024. In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2019.

A/F ratio learn value idle, bank 1 CHR_AF_LEARN_IDLE_PORT_B1Confirmed

  • Request22 10 A2
  • Service 22DID 10A2
  • Module700 → 708
  • Every3600 s
  • Testing for 2016 to 2023, 2025 to 2026

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 100 ÷ 255 − 50)
Range
-50 to 50 %
Unit
%

Confirmed for 2024. In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2019.

A/F ratio learn value low, bank 1 CHR_AF_LEARN_LOW_PORT_B1Confirmed

  • Request22 10 A2
  • Service 22DID 10A2
  • Module700 → 708
  • Every3600 s
  • Testing for 2016 to 2023, 2025 to 2026

Bits 8 to 15 of the reply, 8 bits.

Formula
(val × 100 ÷ 255 − 50)
Range
-50 to 50 %
Unit
%

Confirmed for 2024. In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2019.

A/F ratio learn value mid.1, bank 1 CHR_AF_LEARN_MID1_PORT_B1Confirmed

  • Request22 10 A2
  • Service 22DID 10A2
  • Module700 → 708
  • Every3600 s
  • Testing for 2016 to 2023, 2025 to 2026

Example reply from a 2024 Toyota C-HR.

Bits 16 to 23 of the reply, 8 bits.

0x8B = 139 → (139 × 100 ÷ 255 − 50) = 4.509804 %

Formula
(val × 100 ÷ 255 − 50)
Range
-50 to 50 %
Unit
%

Confirmed for 2024. In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2019.

A/F ratio learn value mid.2, bank 1 CHR_AF_LEARN_MID2_PORT_B1Confirmed

  • Request22 10 A2
  • Service 22DID 10A2
  • Module700 → 708
  • Every3600 s
  • Testing for 2016 to 2023, 2025 to 2026

Bits 24 to 31 of the reply, 8 bits.

Formula
(val × 100 ÷ 255 − 50)
Range
-50 to 50 %
Unit
%

Confirmed for 2024. In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2019.

A/F ratio learned high, bank 1 CHR_A_F_RATIO_LEARNED_HIGH_BANK_1Confirmed

  • Request22 10 2A
  • Service 22DID 102A
  • Module700 → 708
  • Every3600 s
  • Testing for 2016 to 2018, 2020 to 2022, 2026

Example reply from a 2025 Toyota C-HR.

Bits 32 to 39 of the reply, 8 bits.

0x91 = 145 → (145 × 100 ÷ 255 − 50) = 6.862745 %

Formula
(val × 100 ÷ 255 − 50)
Range
-50 to 50 %
Unit
%

Confirmed for 2019, 2023 to 2025. In testing for 2016 to 2018, 2020 to 2022, 2026.

A/F ratio learned idle, bank 1 CHR_A_F_RATIO_LEARNED_IDLE_BANK_1Confirmed

  • Request22 10 2A
  • Service 22DID 102A
  • Module700 → 708
  • Every3600 s
  • Testing for 2016 to 2018, 2020 to 2022, 2026

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 100 ÷ 255 − 50)
Range
-50 to 50 %
Unit
%

Confirmed for 2019, 2023 to 2025. In testing for 2016 to 2018, 2020 to 2022, 2026.

A/F ratio learned low, bank 1 CHR_A_F_RATIO_LEARNED_LOW_BANK_1Confirmed

  • Request22 10 2A
  • Service 22DID 102A
  • Module700 → 708
  • Every3600 s
  • Testing for 2016 to 2018, 2020 to 2022, 2026

Bits 8 to 15 of the reply, 8 bits.

Formula
(val × 100 ÷ 255 − 50)
Range
-50 to 50 %
Unit
%

Confirmed for 2019, 2023 to 2025. In testing for 2016 to 2018, 2020 to 2022, 2026.

A/F ratio learned mid 1, bank 1 CHR_A_F_RATIO_LEARNED_MID_1_BANK_1Confirmed

  • Request22 10 2A
  • Service 22DID 102A
  • Module700 → 708
  • Every3600 s
  • Testing for 2016 to 2018, 2020 to 2022, 2026

Example reply from a 2025 Toyota C-HR.

Bits 16 to 23 of the reply, 8 bits.

0x97 = 151 → (151 × 100 ÷ 255 − 50) = 9.215686 %

Formula
(val × 100 ÷ 255 − 50)
Range
-50 to 50 %
Unit
%

Confirmed for 2019, 2023 to 2025. In testing for 2016 to 2018, 2020 to 2022, 2026.

A/F ratio learned mid 2, bank 1 CHR_A_F_RATIO_LEARNED_MID_2_BANK_1Confirmed

  • Request22 10 2A
  • Service 22DID 102A
  • Module700 → 708
  • Every3600 s
  • Testing for 2016 to 2018, 2020 to 2022, 2026

Example reply from a 2025 Toyota C-HR.

Bits 24 to 31 of the reply, 8 bits.

0x8E = 142 → (142 × 100 ÷ 255 − 50) = 5.686275 %

Formula
(val × 100 ÷ 255 − 50)
Range
-50 to 50 %
Unit
%

Confirmed for 2019, 2023 to 2025. In testing for 2016 to 2018, 2020 to 2022, 2026.

A/F test results 1, incomplete CHR_F_TEST_RESULTS_1

  • Request21 E3
  • Service 21PID E3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 15 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2016 to 2026.

Accessory relay on CHR_ACC_RELAY_ON

  • Request21 39
  • Service 21PID 39
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bit 46 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2016 to 2026.

Accumulator open CHR_ACCUMULATOR_OPENConfirmed

  • Request21 BE
  • Service 21PID BE
  • Module7B0 → 7B8
  • Every1 s
  • Testing for 2016 to 2018, 2020 to 2026

Example reply from a 2019 Toyota C-HR.

Bit 16 of the reply.

0b0 = 0 → 0

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2019. In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2024.

Acoustic control induction system vacuum switching valve on CHR_ACIS_VSV_ON

  • Request21 39
  • Service 21PID 39
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2016 to 2026.

Actual engine torque CHR_ACT_ENG_TQ

  • Request21 49
  • Service 21PID 49
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 24 to 39 of the reply, 16 bits.

Formula
(val − 32768)
Range
-32768 to 32767 N·m
Unit
N·m

In testing for 2016 to 2026.

Actuator power supply on CHR_ACTUATOR_POWER_SUP_ON

  • Request21 41
  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bit 146 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2016 to 2026.

Air conditioning compressor CHR_AC_COMP

  • Request21 E6
  • Service 21PID E6
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2016 to 2026.

Air conditioning power consumption CHR_AC_POWER_CONS

  • Request22 10 6E
  • Service 22DID 106E
  • Module7D2 → 7DA
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 20)
Range
0 to 12.75 kW
Unit
kW

In testing for 2019 to 2026.

Air mix servo target pulse, driver CHR_AIR_MIX_SERVO_TARG_D

  • Request21 41
  • Service 21PID 41
  • Module7C4 → 7CC
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2016 to 2026.

Air mix servo, actual pulse, d CHR_AIR_MIX_SERVO_ACT_D

  • Request21 41
  • Service 21PID 41
  • Module7C4 → 7CC
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2016 to 2026.

Air-fuel equivalence ratio, bank 1 sensor 1 CHR_AF_LAMBDA_B1S1

Pelican can show this parameter as the O2 lambda.

  • Request21 04
  • Service 21PID 04
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
(val × 1.99 ÷ 65535)
Range
0 to 1.99
Unit
Number

In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2019, 2024.

Air-fuel sensor current, bank 1 sensor 1 CHR_AFS_I_B1S1

  • Request21 04
  • Service 21PID 04
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 96 to 111 of the reply, 16 bits.

Formula
(val ÷ 256 − 128)
Range
-128 to 127.99 mA
Unit
mA

In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2019, 2024.

Air-fuel sensor voltage, bank 1 sensor 1 CHR_AFS_V_B1S1

  • Request21 04
  • Service 21PID 04
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
(val × 7.99 ÷ 65535)
Range
0 to 7.99 V
Unit
V

In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2019, 2024.

Alt voltage - active test CHR_ALT_VOL_ACTIVE_TEST

  • Request21 42
  • Service 21PID 42
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
(val × 5 ÷ 4096)
Range
0 to 79.998 V
Unit
V

In testing for 2016 to 2026.

Alt voltage - non active test CHR_ALT_VOL_NON_ACTIVE

  • Request21 42
  • Service 21PID 42
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
(val × 5 ÷ 4096)
Range
0 to 79.998 V
Unit
V

In testing for 2016 to 2026.

Alternator output duty CHR_ALTERNATOR_OUTPUT

  • Request21 42
  • Service 21PID 42
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
(val × 25 ÷ 4096)
Range
0 to 399.9 %
Unit
%

In testing for 2016 to 2026.

Alternator output duty cycle CHR_ALT_DUTY_CYCLE

  • Request22 15 FA
  • Service 22DID 15FA
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 164)
Range
0 to 399 %
Unit
%

In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2019, 2024.

Ambient temperature CHR_AAT_7D2Confirmed

  • Request22 1F 46
  • Service 22DID 1F46
  • Module7D2 → 7DA
  • Every1 s
  • Testing for 2020 to 2022, 2026

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2019, 2023 to 2025. In testing for 2020 to 2022, 2026.

Barometric pressure CHR_BARO

  • Request21 01
  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 48 to 55 of the reply, 8 bits.

Formula
val
Range
0 to 255 kPa
Unit
kPa

In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2019, 2024.

Calculated load CHR_LOAD

Pelican can show this parameter as the engine load.

  • Request21 01
  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2019, 2024.

Catalyst temperature bank 2 sensor 1 CHR_CAT_T_BANK_2_SENS_1

  • Request22 1F 3D
  • Service 22DID 1F3D
  • Module700 → 708
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 9 ÷ 50 − 40)
Range
-40 to 11756.3 °F
Unit
°F

In testing for 2016 to 2026.

Catalyst temperature bank 2 sensor 2 CHR_CAT_T_BANK_2_SENS_2

  • Request22 1F 3F
  • Service 22DID 1F3F
  • Module700 → 708
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 9 ÷ 50 − 40)
Range
-40 to 11756.3 °F
Unit
°F

In testing for 2016 to 2026.

Catalyst temperature, bank 1 sensor 1 CHR_CAT_T_B1S1

  • Request21 05
  • Service 21PID 05
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
(val ÷ 10 − 40)
Range
-40 to 6513.5 °C
Unit
°C

In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2019, 2024.

Catalyst temperature, bank 1 sensor 2 CHR_CAT_T_B1S2

  • Request21 05
  • Service 21PID 05
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
(val ÷ 10 − 40)
Range
-40 to 6513.5 °C
Unit
°C

In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2019, 2024.

Catalyst temperature, bank 1 sensor 2, variant 2 CHR_CAT_T_B1S2_V2

  • Request21 3E
  • Service 21PID 3E
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10 − 40)
Range
-40 to 6513.5 °C
Unit
°C

In testing for 2016 to 2026.

Check mode on CHR_CHECK_MODE_ON

  • Request21 E3
  • Service 21PID E3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2016 to 2026.

Closed throttle position switch on CHR_CLOSED_THROTTLE_POS_ON

  • Request21 37
  • Service 21PID 37
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bit 125 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2016 to 2026.

Codes, include history CHR_CODES_INCLUDE

  • Request21 E1
  • Service 21PID E1
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2016 to 2026.

Continuously variable transmission learning complete CHR_CVT_LEARNED

  • Request21 DD
  • Service 21PID DD
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

In testing for 2016 to 2026.

Continuously variable transmission oil pressure CHR_CVT_OIL_P

  • Request21 BE
  • Service 21PID BE
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 40)
Range
0 to 10200 kPa
Unit
kPa

In testing for 2016 to 2026.

Coolant temperature CHR_COOL_TConfirmed

  • Request22 1F 05
  • Service 22DID 1F05
  • Module7D2 → 7DA
  • Every1 s
  • Testing for 2020 to 2022, 2026

Example reply from a 2025 Toyota C-HR.

Bits 0 to 7 of the reply, 8 bits.

0x42 = 66 → (66 − 40) = 26 °C

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2019, 2023 to 2025. In testing for 2020 to 2022, 2026.

Coolant water route switching valve 1, closed? CHR_COOLANT_VALVE_1_CLOSEConfirmed

  • Request22 28 2C
  • Service 22DID 282C
  • Module700 → 708
  • Every1 s
  • Testing for 2016 to 2018, 2020 to 2026

Example reply from a 2019 Toyota C-HR.

Bit 15 of the reply.

0b0 = 0 → 0

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2019. In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2024.

Coolant water route switching valve 2, closed? CHR_COOLANT_VALVE_2_CLOSE

  • Request22 28 47
  • Service 22DID 2847
  • Module700 → 708
  • Every1 s
  • Testing

Bit 15 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2019, 2024.

Cooling fan duty ratio CHR_COOLING_FAN_DUTY_RATIO

  • Request22 10 46
  • Service 22DID 1046
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 127.5 ÷ 255)
Range
0 to 127.5 %
Unit
%

In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2019, 2024.

Cruise control on CHR_CRUISE_CTRL_ON

  • Request21 D3
  • Service 21PID D3
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bit 25 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2016 to 2026.

Cylinder 1 injection volume CHR_CYL_1_INJ_VOLUME

  • Request22 11 31
  • Service 22DID 1131
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 19531 ÷ 1000000 − 640)
Range
-640 to 15
Unit
Raw value

In testing for 2016 to 2026.

Cylinder 2 injection volume CHR_CYL_2_INJ_VOLUME

  • Request22 11 31
  • Service 22DID 1131
  • Module700 → 708
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
(val × 19531 ÷ 1000000 − 640)
Range
-640 to 15
Unit
Raw value

In testing for 2016 to 2026.

Cylinder 3 injection volume CHR_CYL_3_INJ_VOLUME

  • Request22 11 31
  • Service 22DID 1131
  • Module700 → 708
  • Every1 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
(val × 19531 ÷ 1000000 − 640)
Range
-640 to 15
Unit
Raw value

In testing for 2016 to 2026.

Cylinder 4 injection volume CHR_CYL_4_INJ_VOLUME

  • Request22 11 31
  • Service 22DID 1131
  • Module700 → 708
  • Every1 s
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
(val × 19531 ÷ 1000000 − 640)
Range
-640 to 15
Unit
Raw value

In testing for 2016 to 2026.

Cylinder number CHR_CYLINDER_NUMBER

  • Request21 C1
  • Service 21PID C1
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 104 to 111 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2016 to 2026.

Destination CHR_DESTINATION

  • Request21 C1
  • Service 21PID C1
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 120 to 127 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2016 to 2026.

Dist battery cable disconnect CHR_DIST_BATT_CABLE

  • Request21 37
  • Service 21PID 37
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 96 to 111 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

In testing for 2016 to 2026.

Electric fan motor on CHR_ELEC_FAN_MOTOR_ON

  • Request21 39
  • Service 21PID 39
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bit 34 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2016 to 2026.

Electric thermostat duty ratio CHR_ELECTRIC_THERMOSTAT_DUTY_RATIO

  • Request22 28 29
  • Service 22DID 2829
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2019, 2024.

Electric water pump CHR_ELECTRIC_WATER_PUMPConfirmed

  • Request22 28 27
  • Service 22DID 2827
  • Module700 → 708
  • Every1 s
  • Testing for 2016 to 2018, 2020 to 2023, 2025 to 2026

Example reply from a 2024 Toyota C-HR.

Bits 0 to 7 of the reply, 8 bits.

0x38 = 56 → (56 × 40) = 2,240 rpm

Formula
(val × 40)
Range
0 to 10200 rpm
Unit
rpm

Confirmed for 2019, 2024. In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026.

Electric water pump RPM CHR_EWP_RPMConfirmed

  • Request22 10 43
  • Service 22DID 1043
  • Module700 → 708
  • Every250 ms
  • Testing for 2016 to 2018, 2020 to 2022, 2026

Example reply from a 2025 Toyota C-HR.

Bits 8 to 15 of the reply, 8 bits.

0x00 = 0 → (0 × 25) = 0 rpm

Formula
(val × 25)
Range
0 to 6375 rpm
Unit
rpm

Confirmed for 2019, 2023 to 2025. In testing for 2016 to 2018, 2020 to 2022, 2026.

Electric water pump target speed CHR_EWP_TARGET_VSSConfirmed

  • Request22 10 43
  • Service 22DID 1043
  • Module700 → 708
  • Every250 ms
  • Testing for 2016 to 2018, 2020 to 2022, 2026

Example reply from a 2025 Toyota C-HR.

Bits 0 to 7 of the reply, 8 bits.

0x00 = 0 → (0 × 25) = 0 rpm

Formula
(val × 25)
Range
0 to 6375 rpm
Unit
rpm

Confirmed for 2019, 2023 to 2025. In testing for 2016 to 2018, 2020 to 2022, 2026.

Engine coolant temperature CHR_ECTConfirmed

Pelican can show this parameter as the engine coolant temperature.

  • Request21 26
  • Service 21PID 26
  • Module7C4 → 7CC
  • Every5 s
  • Testing for 2016 to 2018, 2020 to 2026

Example reply from a 2019 Toyota C-HR.

Bits 0 to 7 of the reply, 8 bits.

0x2B = 43 → (43 × 89.25 ÷ 255 + 1.3) = 16.35 °C

Formula
(val × 89.25 ÷ 255 + 1.3)
Range
1.3 to 90.55 °C
Unit
°C

Confirmed for 2019. In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2024.

Engine coolant temperature CHR_ECT_7C0Confirmed

Pelican can show this parameter as the engine coolant temperature.

  • Request21 23
  • Service 21PID 23
  • Module7C0 → 7C8
  • Every5 s
  • Testing for 2016 to 2018, 2020 to 2026

Example reply from a 2019 Toyota C-HR.

Bits 0 to 7 of the reply, 8 bits.

0x00 = 0 → (0 ÷ 2) = 0 °C

Formula
(val ÷ 2)
Range
0 to 127.5 °C
Unit
°C

Confirmed for 2019. In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2024.

Engine coolant temperature CHR_ECT_7E0

Pelican can show this parameter as the engine coolant temperature.

  • Request21 01
  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 56 to 63 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2019, 2024.

Engine coolant temperature, at ignition CHR_ECT_IGNConfirmed

  • Request22 10 41
  • Service 22DID 1041
  • Module700 → 708
  • Every5 s
  • Testing for 2016 to 2018, 2020 to 2023, 2025 to 2026

Example reply from a 2024 Toyota C-HR.

Bits 0 to 7 of the reply, 8 bits.

0x99 = 153 → (153 × 62.5 ÷ 100 − 40) = 55.625 °C

Formula
(val × 62.5 ÷ 100 − 40)
Range
-40 to 119.375 °C
Unit
°C

Confirmed for 2019, 2024. In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026.

Engine coolant temperature, initial CHR_ECT_INITConfirmed

  • Request22 10 41
  • Service 22DID 1041
  • Module700 → 708
  • Every5 s
  • Testing for 2016 to 2018, 2020 to 2023, 2025 to 2026

Example reply from a 2024 Toyota C-HR.

Bits 8 to 15 of the reply, 8 bits.

0x86 = 134 → (134 × 62.5 ÷ 100 − 40) = 43.75 °C

Formula
(val × 62.5 ÷ 100 − 40)
Range
-40 to 119.375 °C
Unit
°C

Confirmed for 2019, 2024. In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026.

Engine independent CHR_ENG_INDEPENDENT

  • Request21 49
  • Service 21PID 49
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bit 91 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2016 to 2026.

Engine independent control CHR_ENG_INDEPENDENT_CTRL

  • Request21 49
  • Service 21PID 49
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bit 88 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2016 to 2026.

Engine oil pressure CHR_EOPConfirmed

  • Request22 10 74
  • Service 22DID 1074
  • Module700 → 708
  • Every1 s
  • Testing for 2016 to 2023, 2025 to 2026

Example reply from a 2024 Toyota C-HR.

Bits 0 to 15 of the reply, 16 bits.

0x0000 = 0 → (0 × 10 ÷ 128) = 0 kPa

Formula
(val × 10 ÷ 128)
Range
0 to 5119.92 kPa
Unit
kPa

Confirmed for 2024. In testing for 2016 to 2018, 2020 to 2021, 2026. Not supported for 2019, 2022 to 2023, 2025.

Engine oil pressure control valve CHR_EOP_CONTROL_VALVEConfirmed

  • Request22 28 48
  • Service 22DID 2848
  • Module700 → 708
  • Every1 s
  • Testing for 2016 to 2023, 2025 to 2026

Example reply from a 2024 Toyota C-HR.

Bits 0 to 15 of the reply, 16 bits.

0x051E = 1310 → (1310 × 0.0762939) = 99.945009 mA

Formula
(val × 0.0762939)
Range
0 to 4999.9207 mA
Unit
mA

Confirmed for 2024. In testing for 2016 to 2018, 2020 to 2022, 2026. Not supported for 2019, 2023, 2025.

Engine oil temperature CHR_EOTConfirmed

Pelican can show this parameter as the engine oil temperature.

  • Request21 51
  • Service 21PID 51
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2016 to 2018, 2020 to 2026

Example reply from a 2019 Toyota C-HR.

Bits 72 to 79 of the reply, 8 bits.

0x53 = 83 → (83 − 40) = 43 °C

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2019. In testing for 2016 to 2018, 2020 to 2021, 2026. Not supported for 2022 to 2025.

Engine oil temperature CHR_EOT_700

Pelican can show this parameter as the engine oil temperature.

  • Request22 10 7B
  • Service 22DID 107B
  • Module700 → 708
  • Every5 s
  • Testing

Bits 192 to 199 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2016 to 2018, 2020 to 2022, 2026. Not supported for 2019, 2023 to 2025.

Engine oil temperature, variation 2 CHR_EOT_V2Confirmed

Pelican can show this parameter as the engine oil temperature.

  • Request22 1F 5C
  • Service 22DID 1F5C
  • Module700 → 708
  • Every5 s
  • Testing for 2016 to 2023, 2025 to 2026

Example reply from a 2024 Toyota C-HR.

Bits 0 to 7 of the reply, 8 bits.

0x53 = 83 → (83 − 40) = 43 °C

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2024. In testing for 2016 to 2018, 2020 to 2022, 2026. Not supported for 2019, 2023, 2025.

Engine run time, up to 255 sec. only CHR_ENG_RUN_TIME_UP_255

  • Request21 49
  • Service 21PID 49
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
val
Range
0 to 255 s
Unit
s

In testing for 2016 to 2026.

Engine stall control FB flow CHR_ENG_STALL_CTRL_FB

  • Request21 52
  • Service 21PID 52
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
(val × 5 ÷ 4096 − 40)
Range
-40 to 39.99
Unit
Number

In testing for 2016 to 2026.

Evaporative purge duty CHR_EVAP_PURGE_DUTY_7E0

  • Request21 2E
  • Service 21PID 2E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 20 ÷ 51)
Range
0 to 100 %
Unit
%

In testing for 2016 to 2026.

Evaporative purge flow CHR_EVAP_PURGE_FLOW

  • Request21 37
  • Service 21PID 37
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
(val × 25 ÷ 4096)
Range
0 to 399.99 %
Unit
%

In testing for 2016 to 2026.

Evaporative purge vacuum switching valve on CHR_EVAP_PURGE_VSV_ON

  • Request21 39
  • Service 21PID 39
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bit 11 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2016 to 2026.

Exhaust gas recirculation step position CHR_EGR_STEP_POSITION

  • Request21 47
  • Service 21PID 47
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2016 to 2026.

Exhaust gas recirculation temperature CHR_EGR_T

  • Request21 ED
  • Service 21PID ED
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 53 ÷ 85)
Range
0 to 159 °C
Unit
°C

In testing for 2016 to 2026.

Exhaust gas recirculation valve step CHR_EGR_STEP

  • Request21 E7
  • Service 21PID E7
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2016 to 2026.

Exhaust VVT change angle, bank 1 CHR_EXHAUST_VVT_ANGLE_B1Confirmed

  • Request22 10 88
  • Service 22DID 1088
  • Module700 → 708
  • Every1 s
  • Testing for 2016 to 2023, 2025 to 2026

Example reply from a 2024 Toyota C-HR.

Bits 0 to 15 of the reply, 16 bits.

0x0000 = 0 → (0 × 639.9 ÷ 65535) = 0 °

Formula
(val × 639.9 ÷ 65535)
Range
0 to 639.9 °
Unit
°

Confirmed for 2024. In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2019.

Exhaust VVT hold learn value, bank 1 CHR_EXHAUST_VVT_HOLD_LEARN_B1Confirmed

  • Request22 10 89
  • Service 22DID 1089
  • Module700 → 708
  • Every3600 s
  • Testing for 2016 to 2023, 2025 to 2026

Example reply from a 2024 Toyota C-HR.

Bits 0 to 15 of the reply, 16 bits.

0x1FF1 = 8177 → (8177 × 399.9 ÷ 65535) = 49.896732 %

Formula
(val × 399.9 ÷ 65535)
Range
0 to 399.9 %
Unit
%

Confirmed for 2024. In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2019.

Exhaust VVT oil control valve control duty CHR_EXHAUST_VVT_OCV_CONTROL_DUTYConfirmed

  • Request22 10 62
  • Service 22DID 1062
  • Module700 → 708
  • Every1 s
  • Testing for 2016 to 2023, 2025 to 2026

Example reply from a 2024 Toyota C-HR.

Bits 0 to 15 of the reply, 16 bits.

0x06EC = 1772 → (1772 × 400 ÷ 65535) = 10.815595 %

Formula
(val × 400 ÷ 65535)
Range
0 to 400 %
Unit
%

Confirmed for 2024. In testing for 2016 to 2018, 2020 to 2022, 2026. Not supported for 2019, 2023, 2025.

Exhaust VVT target angle B1 CHR_EXHAUST_VVT_TARGET_ANGLE_B1Confirmed

  • Request22 10 71
  • Service 22DID 1071
  • Module700 → 708
  • Every1 s
  • Testing for 2016 to 2023, 2025 to 2026

Example reply from a 2024 Toyota C-HR.

Bits 0 to 15 of the reply, 16 bits.

0x0000 = 0 → (0 × 639.9 ÷ 65535) = 0 °

Formula
(val × 639.9 ÷ 65535)
Range
0 to 639.9 °
Unit
°

Confirmed for 2024. In testing for 2016 to 2018, 2020 to 2022, 2026. Not supported for 2019, 2023, 2025.

Exhaust VVT timing most over-advanced learn value, bank 1 CHR_EXHAUST_VVT_OVER_ADV_LEARN_B1Confirmed

  • Request22 10 8F
  • Service 22DID 108F
  • Module700 → 708
  • Every3600 s
  • Testing for 2016 to 2023, 2025 to 2026

Example reply from a 2024 Toyota C-HR.

Bits 0 to 15 of the reply, 16 bits.

0x245A = 9306 → (9306 × 639.99 ÷ 65535) = 90.878873 °

Formula
(val × 639.99 ÷ 65535)
Range
0 to 639.99 °
Unit
°

Confirmed for 2024. In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2019.

Front/rear motor torque ratio CHR_FRONT_REAR_MOTOR_TQ

  • Request22 10 39
  • Service 22DID 1039
  • Module7D2 → 7DA
  • Every250 ms
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
(val ÷ 1000 − 32.768)
Range
-32.76 to 32.76
Unit
Number

In testing for 2019 to 2026.

Fuel cut for engine stop request CHR_F_C_ENG_STOP_REQ

  • Request21 49
  • Service 21PID 49
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bit 92 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2016 to 2026.

Fuel cut TAU on CHR_FC_TAU_ON

  • Request21 37
  • Service 21PID 37
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bit 127 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2016 to 2026.

Fuel filter temperature CHR_FFT

  • Request22 10 9A
  • Service 22DID 109A
  • Module700 → 708
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2019, 2024.

G sensor calibration, complete CHR_G_SENS_CALIBRATION

  • Request21 83
  • Service 21PID 83
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2016 to 2026.

G sensor learning value CHR_G_SENS_LEARNING

  • Request21 83
  • Service 21PID 83
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 8 to 23 of the reply, 16 bits.

Formula
(val × 5 ÷ 4096)
Range
0 to 79.998 V
Unit
V

In testing for 2016 to 2026.

Generator inverter temperature CHR_GEN_INVERTER_T

  • Request22 10 A4
  • Service 22DID 10A4
  • Module7D2 → 7DA
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2019 to 2026.

Generator inverter temperature CHR_GEN_INVERTER_T_7D2

  • Request22 10 A8
  • Service 22DID 10A8
  • Module7D2 → 7DA
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2019 to 2026.

Generator inverter temperature after ignition on CHR_GEN_INVERTER_T_AFTER_ON

  • Request22 10 A8
  • Service 22DID 10A8
  • Module7D2 → 7DA
  • Every5 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2019 to 2026.

Glass humidity CHR_GLASS_HUMIDITY

  • Request21 B1
  • Service 21PID B1
  • Module7C4 → 7CC
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 20 ÷ 13107)
Range
0 to 100 %
Unit
%

In testing for 2016 to 2026.

Glass temperature CHR_GLASS_T

  • Request21 AF
  • Service 21PID AF
  • Module7C4 → 7CC
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 9 ÷ 500 − 557.8)
Range
-557 to 621 °F
Unit
°F

In testing for 2016 to 2026.

Hydraulic valve, communication open CHR_HV_COMM_OPENConfirmed

  • Request21 BE
  • Service 21PID BE
  • Module7B0 → 7B8
  • Every1 s
  • Testing for 2016 to 2018, 2020 to 2026

Example reply from a 2019 Toyota C-HR.

Bit 17 of the reply.

0b0 = 0 → 0

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2019. In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2024.

Idle control CHR_IDLE_CTRL

  • Request21 E6
  • Service 21PID E6
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2016 to 2026.

Idle spark advance control 1 CHR_IDLE_SPARK_ADVN_CTRL_1

  • Request21 52
  • Service 21PID 52
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 16)
Range
0 to 15.93 °
Unit
°

In testing for 2016 to 2026.

Idle spark advance control 2 CHR_IDLE_SPARK_ADVN_CTRL_2

  • Request21 52
  • Service 21PID 52
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
(val ÷ 16)
Range
0 to 15.93 °
Unit
°

In testing for 2016 to 2026.

Idle spark advance control 3 CHR_IDLE_SPARK_ADVN_CTRL_3

  • Request21 52
  • Service 21PID 52
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
(val ÷ 16)
Range
0 to 15.93 °
Unit
°

In testing for 2016 to 2026.

Idle spark advance control 4 CHR_IDLE_SPARK_ADVN_CTRL_4

  • Request21 52
  • Service 21PID 52
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
(val ÷ 16)
Range
0 to 15.93 °
Unit
°

In testing for 2016 to 2026.

Idle spark advance control, cylinder 1 CHR_IDLE_SAC_CYL_1Confirmed

  • Request22 10 78
  • Service 22DID 1078
  • Module700 → 708
  • Every1 s
  • Testing for 2016 to 2018, 2020 to 2022, 2026

Example reply from a 2025 Toyota C-HR.

Bits 0 to 7 of the reply, 8 bits.

0x00 = 0 → (0 × 6.25 ÷ 100) = 0 °

Formula
(val × 6.25 ÷ 100)
Range
0 to 15.9375 °
Unit
°

Confirmed for 2019, 2023 to 2025. In testing for 2016 to 2018, 2020 to 2022, 2026.

Idle spark advance control, cylinder 2 CHR_IDLE_SAC_CYL_2Confirmed

  • Request22 10 78
  • Service 22DID 1078
  • Module700 → 708
  • Every1 s
  • Testing for 2016 to 2018, 2020 to 2022, 2026

Example reply from a 2025 Toyota C-HR.

Bits 8 to 15 of the reply, 8 bits.

0x00 = 0 → (0 × 6.25 ÷ 100) = 0 °

Formula
(val × 6.25 ÷ 100)
Range
0 to 15.9375 °
Unit
°

Confirmed for 2019, 2023 to 2025. In testing for 2016 to 2018, 2020 to 2022, 2026.

Idle spark advance control, cylinder 3 CHR_IDLE_SAC_CYL_3Confirmed

  • Request22 10 78
  • Service 22DID 1078
  • Module700 → 708
  • Every1 s
  • Testing for 2016 to 2018, 2020 to 2022, 2026

Example reply from a 2025 Toyota C-HR.

Bits 16 to 23 of the reply, 8 bits.

0x00 = 0 → (0 × 6.25 ÷ 100) = 0 °

Formula
(val × 6.25 ÷ 100)
Range
0 to 15.9375 °
Unit
°

Confirmed for 2019, 2023 to 2025. In testing for 2016 to 2018, 2020 to 2022, 2026.

Idle spark advance control, cylinder 4 CHR_IDLE_SAC_CYL_4Confirmed

  • Request22 10 78
  • Service 22DID 1078
  • Module700 → 708
  • Every1 s
  • Testing for 2016 to 2018, 2020 to 2022, 2026

Example reply from a 2025 Toyota C-HR.

Bits 24 to 31 of the reply, 8 bits.

0x00 = 0 → (0 × 6.25 ÷ 100) = 0 °

Formula
(val × 6.25 ÷ 100)
Range
0 to 15.9375 °
Unit
°

Confirmed for 2019, 2023 to 2025. In testing for 2016 to 2018, 2020 to 2022, 2026.

Idle speed control learning CHR_IDLE_SPD_CTRL

  • Request21 49
  • Service 21PID 49
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bit 93 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2016 to 2026.

Idle speed control learning value, l/s CHR_IDLE_SPD_CTRL_L_S

  • Request21 49
  • Service 21PID 49
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 72 to 87 of the reply, 16 bits.

Formula
(val × 0.0012206912)
Range
0 to 79.99
Unit
Number

In testing for 2016 to 2026.

IG OFF elapsed time CHR_IG_OFF_ELAPSED_TIME

  • Request21 37
  • Service 21PID 37
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 80 to 95 of the reply, 16 bits.

Formula
(val × 10)
Range
0 to 655350 min
Unit
min

In testing for 2016 to 2026.

Ignition advance CHR_SPARKADV_21

  • Request21 0E
  • Service 21PID 0E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 2 − 64)
Range
-64 to 63.5 °
Unit
°

In testing for 2016 to 2026.

Ignition timing advance CHR_IGN_ADVANCE

  • Request21 03
  • Service 21PID 03
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 48 to 55 of the reply, 8 bits.

Formula
(val ÷ 2 − 64)
Range
-64 to 63.5 °
Unit
°

In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2019, 2024.

Immobilizer communication on CHR_IMMOBILIZER_ON

  • Request21 37
  • Service 21PID 37
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bit 120 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2016 to 2026.

Initial engine coolant temperature CHR_INITIAL_ECT

  • Request21 37
  • Service 21PID 37
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 531 ÷ 850 − 40)
Range
-40 to 119.3
Unit
Number

In testing for 2016 to 2026.

Initial intake air temperature CHR_INITIAL_IAT

  • Request21 37
  • Service 21PID 37
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
(val × 5 ÷ 8 − 40)
Range
-40 to 119 °C
Unit
°C

In testing for 2016 to 2026.

Injection CHR_INJECTION

  • Request22 10 19
  • Service 22DID 1019
  • Module700 → 708
  • Every1 s
  • Testing for 2016 to 2023, 2025 to 2026

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
1DIRECTDirect
2BOTHBoth

In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Supported for 2024. Not supported for 2019.

Injection duration for cylinder 1 CHR_INJ_DUR_CYL_1

  • Request21 3C
  • Service 21PID 3C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 ms
Unit
ms

In testing for 2016 to 2026.

Injection feedback value 1 CHR_INJ_FEEDBACK_1

  • Request22 11 2B
  • Service 22DID 112B
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 5 ÷ 32 − 20)
Range
-20 to 15
Unit
Raw value

In testing for 2016 to 2026.

Injection feedback value 1 CHR_INJ_FEEDBACK_1_700

  • Request22 11 B8
  • Service 22DID 11B8
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 332 ÷ 2125 − 19.99811765)
Range
-19.9981 to 19.8418
Unit
Raw value

In testing for 2016 to 2026.

Injection feedback value 2 CHR_INJ_FEEDBACK_2

  • Request22 11 2B
  • Service 22DID 112B
  • Module700 → 708
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
(val × 5 ÷ 32 − 20)
Range
-20 to 15
Unit
Raw value

In testing for 2016 to 2026.

Injection feedback value 2 CHR_INJ_FEEDBACK_2_700

  • Request22 11 B8
  • Service 22DID 11B8
  • Module700 → 708
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
(val × 332 ÷ 2125 − 19.99811765)
Range
-19.9981 to 19.8418
Unit
Raw value

In testing for 2016 to 2026.

Injection feedback value 3 CHR_INJ_FEEDBACK_3

  • Request22 11 2B
  • Service 22DID 112B
  • Module700 → 708
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
(val × 5 ÷ 32 − 20)
Range
-20 to 15
Unit
Raw value

In testing for 2016 to 2026.

Injection feedback value 3 CHR_INJ_FEEDBACK_3_700

  • Request22 11 B8
  • Service 22DID 11B8
  • Module700 → 708
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
(val × 332 ÷ 2125 − 19.99811765)
Range
-19.9981 to 19.8418
Unit
Raw value

In testing for 2016 to 2026.

Injection feedback value 4 CHR_INJ_FEEDBACK_4

  • Request22 11 2B
  • Service 22DID 112B
  • Module700 → 708
  • Every1 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
(val × 5 ÷ 32 − 20)
Range
-20 to 15
Unit
Raw value

In testing for 2016 to 2026.

Injection feedback value 4 CHR_INJ_FEEDBACK_4_700

  • Request22 11 B8
  • Service 22DID 11B8
  • Module700 → 708
  • Every1 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
(val × 332 ÷ 2125 − 19.99811765)
Range
-19.9981 to 19.8418
Unit
Raw value

In testing for 2016 to 2026.

Injection feedback value 5 CHR_INJ_FEEDBACK_5

  • Request22 11 B8
  • Service 22DID 11B8
  • Module700 → 708
  • Every1 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
(val × 332 ÷ 2125 − 19.99811765)
Range
-19.9981 to 19.8418
Unit
Raw value

In testing for 2016 to 2026.

Injection feedback value 6 CHR_INJ_FEEDBACK_6

  • Request22 11 B8
  • Service 22DID 11B8
  • Module700 → 708
  • Every1 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
(val × 332 ÷ 2125 − 19.99811765)
Range
-19.9981 to 19.8418
Unit
Raw value

In testing for 2016 to 2026.

Injection volume CHR_INJ_VOLConfirmed

  • Request22 10 17
  • Service 22DID 1017
  • Module700 → 708
  • Every1 s
  • Testing for 2016 to 2018, 2020 to 2022, 2026

Example reply from a 2025 Toyota C-HR.

Bits 0 to 15 of the reply, 16 bits.

0x0000 = 0 → (0 ÷ 3200) = 0 L

Formula
(val ÷ 3200)
Range
0 to 20 L
Unit
L

Confirmed for 2019, 2023 to 2025. In testing for 2016 to 2018, 2020 to 2022, 2026.

Injection volume - target CHR_INJ_VOLUME_TGT

  • Request22 11 2C
  • Service 22DID 112C
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 19531 ÷ 1000000)
Range
0 to 15
Unit
Raw value

In testing for 2016 to 2026.

Injection volume 1 CHR_INJ_VOLUME_1

  • Request22 11 8B
  • Service 22DID 118B
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 19531 ÷ 1000000 − 640)
Range
-40 to 300
Unit
Raw value

In testing for 2016 to 2026.

Injection volume 2 CHR_INJ_VOLUME_2

  • Request22 11 8B
  • Service 22DID 118B
  • Module700 → 708
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
(val × 19531 ÷ 1000000 − 640)
Range
-40 to 300
Unit
Raw value

In testing for 2016 to 2026.

Injection volume 3 CHR_INJ_VOLUME_3

  • Request22 11 8B
  • Service 22DID 118B
  • Module700 → 708
  • Every1 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
(val × 19531 ÷ 1000000 − 640)
Range
-40 to 300
Unit
Raw value

In testing for 2016 to 2026.

Injection volume 5 CHR_INJ_VOLUME_5

  • Request22 11 8B
  • Service 22DID 118B
  • Module700 → 708
  • Every1 s
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
(val × 19531 ÷ 1000000 − 640)
Range
-40 to 300
Unit
Raw value

In testing for 2016 to 2026.

Injection volume 6 CHR_INJ_VOLUME_6

  • Request22 11 8B
  • Service 22DID 118B
  • Module700 → 708
  • Every1 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
(val × 19531 ÷ 1000000 − 640)
Range
-40 to 300
Unit
Raw value

In testing for 2016 to 2026.

Injection volume per 10 injections, cylinder 1 CHR_INJ_VOL_CYL_1

  • Request21 3C
  • Service 21PID 3C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 32000000)
Range
0 to 0.002 L
Unit
L

In testing for 2016 to 2026.

Injection volume total CHR_INJ_VOLUME_TOT

  • Request22 11 2F
  • Service 22DID 112F
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 19531 ÷ 1000000 − 640)
Range
-640 to 15
Unit
Raw value

In testing for 2016 to 2026.

Injector port CHR_INJECTOR_PORTConfirmed

  • Request22 10 18
  • Service 22DID 1018
  • Module700 → 708
  • Every1 s
  • Testing for 2016 to 2018, 2020 to 2023, 2025 to 2026

Example reply from a 2024 Toyota C-HR.

Bits 0 to 15 of the reply, 16 bits.

0x0000 = 0 → (0 ÷ 1000) = 0 ms

Formula
(val ÷ 1000)
Range
0 to 65.535 ms
Unit
ms

Confirmed for 2019, 2024. In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026.

Injector pulse width CHR_INJ_PW

  • Request21 E4
  • Service 21PID E4
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 163 ÷ 1275)
Range
0 to 32.6 ms
Unit
ms

In testing for 2016 to 2026.

Injector pulse width CHR_INJ_WIDTH

  • Request21 F3
  • Service 21PID F3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
(val × 16 ÷ 125)
Range
0 to 32.64 ms
Unit
ms

In testing for 2016 to 2026.

Input shaft speed CHR_SPD_NIN

  • Request21 81
  • Service 21PID 81
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
(val × 50)
Range
0 to 12750 rpm
Unit
rpm

In testing for 2016 to 2026.

Intake air temperature CHR_IAT

  • Request21 01
  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2019, 2024.

Intake air temperature CHR_IAT_21

  • Request21 0F
  • Service 21PID 0F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2016 to 2026.

Intake air temperature, bank 1 sensor 1 CHR_IAT_B1S1

  • Request22 1F 77
  • Service 22DID 1F77
  • Module700 → 708
  • Every5 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2016 to 2026.

Intake air temperature, bank 1 sensor 2 CHR_IAT_B1S2

  • Request22 1F 77
  • Service 22DID 1F77
  • Module700 → 708
  • Every5 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2016 to 2026.

Intake VVT change angle, bank 1 CHR_INTAKE_VVT_CHANGE_ANGLE_BANK_1Confirmed

  • Request22 10 87
  • Service 22DID 1087
  • Module700 → 708
  • Every1 s
  • Testing for 2016 to 2018, 2020 to 2022, 2026

Example reply from a 2025 Toyota C-HR.

Bits 0 to 15 of the reply, 16 bits.

0x0000 = 0 → (0 × 639.9 ÷ 65535) = 0 °

Formula
(val × 639.9 ÷ 65535)
Range
0 to 639.9 °
Unit
°

Confirmed for 2019, 2023 to 2025. In testing for 2016 to 2018, 2020 to 2022, 2026.

Intake VVT most over-retarded learn value, bank 1 CHR_INTAKE_VVT_OVER_RET_LEARN_B1Confirmed

  • Request22 10 8D
  • Service 22DID 108D
  • Module700 → 708
  • Every3600 s
  • Testing for 2016 to 2023, 2025 to 2026

Example reply from a 2024 Toyota C-HR.

Bits 0 to 15 of the reply, 16 bits.

0x0D48 = 3400 → (3400 × 639.99 ÷ 65535) = 33.203113 °

Formula
(val × 639.99 ÷ 65535)
Range
0 to 639.99 °
Unit
°

Confirmed for 2024. In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2019.

Intake VVT target angle B1 CHR_INTAKE_VVT_TARGET_ANGLE_B1Confirmed

  • Request22 10 6F
  • Service 22DID 106F
  • Module700 → 708
  • Every1 s
  • Testing for 2016 to 2018, 2020 to 2022, 2026

Example reply from a 2025 Toyota C-HR.

Bits 0 to 15 of the reply, 16 bits.

0x0000 = 0 → (0 × 639.9 ÷ 65535) = 0 °

Formula
(val × 639.9 ÷ 65535)
Range
0 to 639.9 °
Unit
°

Confirmed for 2019, 2023 to 2025. In testing for 2016 to 2018, 2020 to 2022, 2026.

Integrated engine run time CHR_INTEGRATED_ENG_RUN

  • Request22 15 E8
  • Service 22DID 15E8
  • Module700 → 708
  • Every3600 s
  • Testing

Bits 80 to 95 of the reply, 16 bits.

Formula
val
Range
0 to 65535 h
Unit
h

In testing for 2016 to 2026.

Intercooler coolant temperature CHR_INTERCOOLER_ECT

  • Request22 11 9C
  • Service 22DID 119C
  • Module700 → 708
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2016 to 2026.

Intercooler water pump CHR_INTERCOOLER_WATER

  • Request22 28 20
  • Service 22DID 2820
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 80 ÷ 13107)
Range
0 to 300 %
Unit
%

In testing for 2016 to 2026.

Internal temperature CHR_ECU_INTERNAL_TConfirmed

  • Request22 10 5E
  • Service 22DID 105E
  • Module700 → 708
  • Every5 s
  • Testing for 2016 to 2023, 2026

Example reply from a 2025 Toyota C-HR.

Bits 0 to 7 of the reply, 8 bits.

0x46 = 70 → (70 − 40) = 30 °C

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2024 to 2025. In testing for 2016 to 2018, 2020 to 2022, 2026. Not supported for 2019, 2023.

Inverter coolant temperature CHR_INVRT_COOLANT_TConfirmed

  • Request22 10 B2
  • Service 22DID 10B2
  • Module7D2 → 7DA
  • Every1 s
  • Testing for 2020 to 2022, 2026

Example reply from a 2025 Toyota C-HR.

Bits 0 to 7 of the reply, 8 bits.

0x42 = 66 → (66 − 40) = 26 °C

Formula
(val − 40)
Range
0 to 100 °C
Unit
°C

Confirmed for 2019, 2023 to 2025. In testing for 2020 to 2022, 2026.

Inverter water pump duty CHR_INVERTER_WATER_PMP

  • Request22 11 12
  • Service 22DID 1112
  • Module7D2 → 7DA
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 15259 ÷ 5000000)
Range
0 to 199 %
Unit
%

In testing for 2019 to 2026.

Judge time engine ignition CHR_JUDGE_TIME_ENG_IGN

  • Request21 49
  • Service 21PID 49
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 56 to 63 of the reply, 8 bits.

Formula
(val ÷ 10)
Range
0 to 25.5 s
Unit
s

In testing for 2016 to 2026.

Judge time engine output CHR_JUDGE_TIME_ENG

  • Request21 49
  • Service 21PID 49
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 64 to 71 of the reply, 8 bits.

Formula
(val ÷ 10)
Range
0 to 25.5 s
Unit
s

In testing for 2016 to 2026.

Key cycle CHR_KEY_CYCLE

  • Request22 01 02
  • Service 22DID 0102
  • Module7D2 → 7DA
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2019 to 2026.

Knock adjust CHR_KNOCK_ADJUST

  • Request21 B2
  • Service 21PID B2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 2048 ÷ 65535 − 64)
Range
-64 to 1984 °
Unit
°

In testing for 2016 to 2026.

Knock adjust CHR_KNOCK_ADJUST_7E0

  • Request21 37
  • Service 21PID 37
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
(val × 2048 ÷ 65535 − 1024)
Range
-1024 to 1024 °
Unit
°

In testing for 2016 to 2026.

Knock correct learn value CHR_KNOCK_CORRECT_LEARN

  • Request21 37
  • Service 21PID 37
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
(val ÷ 32 − 1024)
Range
-1024 to 1023 °
Unit
°

In testing for 2016 to 2026.

Knock correction, learned value CHR_KNOCK_CORRECT_LEARNED_VALUEConfirmed

  • Request22 10 5C
  • Service 22DID 105C
  • Module700 → 708
  • Every1 s
  • Testing for 2016 to 2018, 2020 to 2022, 2026

Example reply from a 2025 Toyota C-HR.

Bits 0 to 15 of the reply, 16 bits.

0x81B1 = 33201 → (33201 × 312.5 ÷ 10000 − 1024) = 13.53125

Formula
(val × 312.5 ÷ 10000 − 1024)
Range
-1024 to 1023
Unit
Number

Confirmed for 2019, 2023 to 2025. In testing for 2016 to 2018, 2020 to 2022, 2026.

Knock feedback CHR_KNOCK_FEEDBACK

  • Request21 B2
  • Service 21PID B2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
(val × 2048 ÷ 65535 − 64)
Range
-64 to 1984 °
Unit
°

In testing for 2016 to 2026.

Knock feedback CHR_KNOCK_FEEDBACK_7E0

  • Request21 37
  • Service 21PID 37
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
(val × 2048 ÷ 65535 − 1024)
Range
-1024 to 1024 °
Unit
°

In testing for 2016 to 2026.

Knock feedback value CHR_KNOCK_FEEDBACK_VALUEConfirmed

  • Request22 10 5C
  • Service 22DID 105C
  • Module700 → 708
  • Every1 s
  • Testing for 2016 to 2018, 2020 to 2022, 2026

Example reply from a 2025 Toyota C-HR.

Bits 16 to 31 of the reply, 16 bits.

0x7FA0 = 32672 → (32672 × 312.5 ÷ 10000 − 1024) = -3

Formula
(val × 312.5 ÷ 10000 − 1024)
Range
-1024 to 1023
Unit
Number

Confirmed for 2019, 2023 to 2025. In testing for 2016 to 2018, 2020 to 2022, 2026.

Long term fuel trim, bank 1 CHR_LONG_FT_B1

  • Request21 03
  • Service 21PID 03
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
(val × 200 ÷ 256 − 100)
Range
-100 to 99.21 %
Unit
%

In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2019, 2024.

Long term fuel trim, bank 2 CHR_LONG_FT_B2

  • Request21 03
  • Service 21PID 03
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
(val × 200 ÷ 256 − 100)
Range
-100 to 99.21 %
Unit
%

In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2019, 2024.

Long-term fuel trim, bank 1 CHR_LTFT1_21

  • Request21 07
  • Service 21PID 07
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 0.7809803922 − 100)
Range
-100 to 99.15 %
Unit
%

In testing for 2016 to 2026.

Mass air flow CHR_MAF

Pelican can show this parameter as the mass air flow.

  • Request21 01
  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 24 to 39 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 655.35 g/s
Unit
g/s

In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2019, 2024.

Mass air flow CHR_MAF_21

  • Request21 10
  • Service 21PID 10
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 655 g/s
Unit
g/s

In testing for 2016 to 2026.

Master cylinder open CHR_MASTER_CYLINDER_OPENConfirmed

  • Request21 BE
  • Service 21PID BE
  • Module7B0 → 7B8
  • Every1 s
  • Testing for 2016 to 2018, 2020 to 2026

Example reply from a 2019 Toyota C-HR.

Bit 8 of the reply.

0b0 = 0 → 0

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2019. In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2024.

Master cylinder sensor temperature CHR_MASTER_CYL_TEMP

  • Request22 10 06
  • Service 22DID 1006
  • Module7B0 → 7B8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 80)
Range
-20 to 100 °C
Unit
°C

In testing for 2016 to 2018, 2020 to 2021, 2026. Not supported for 2019, 2022 to 2025.

Maximum generator inverter temperature CHR_MAX_GEN_INVERTER_T

  • Request22 10 A8
  • Service 22DID 10A8
  • Module7D2 → 7DA
  • Every5 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2019 to 2026.

Maximum motor inverter temperature CHR_MAX_MOTOR_INVERTER_T

  • Request22 10 A5
  • Service 22DID 10A5
  • Module7D2 → 7DA
  • Every5 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2019 to 2026.

Misfire count, all cylinders CHR_MISFIRE_CNTConfirmed

  • Request22 10 A5
  • Service 22DID 10A5
  • Module700 → 708
  • Every1 s
  • Testing for 2016 to 2018, 2020 to 2022, 2026

Example reply from a 2025 Toyota C-HR.

Bits 0 to 7 of the reply, 8 bits.

0x00 = 0 → 0

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2019, 2023 to 2025. In testing for 2016 to 2018, 2020 to 2022, 2026.

Misfire count, cylinder 1 CHR_MISFIRE_CYL1Confirmed

  • Request22 10 A7
  • Service 22DID 10A7
  • Module700 → 708
  • Every1 s
  • Testing for 2016 to 2018, 2020 to 2022, 2026

Example reply from a 2025 Toyota C-HR.

Bits 0 to 7 of the reply, 8 bits.

0x00 = 0 → 0

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2019, 2023 to 2025. In testing for 2016 to 2018, 2020 to 2022, 2026.

Misfire count, cylinder 2 CHR_MISFIRE_CYL2Confirmed

  • Request22 10 A7
  • Service 22DID 10A7
  • Module700 → 708
  • Every1 s
  • Testing for 2016 to 2018, 2020 to 2022, 2026

Example reply from a 2025 Toyota C-HR.

Bits 8 to 15 of the reply, 8 bits.

0x00 = 0 → 0

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2019, 2023 to 2025. In testing for 2016 to 2018, 2020 to 2022, 2026.

Misfire count, cylinder 3 CHR_MISFIRE_CYL3Confirmed

  • Request22 10 A7
  • Service 22DID 10A7
  • Module700 → 708
  • Every1 s
  • Testing for 2016 to 2018, 2020 to 2022, 2026

Example reply from a 2025 Toyota C-HR.

Bits 16 to 23 of the reply, 8 bits.

0x00 = 0 → 0

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2019, 2023 to 2025. In testing for 2016 to 2018, 2020 to 2022, 2026.

Misfire count, cylinder 4 CHR_MISFIRE_CYL4Confirmed

  • Request22 10 A7
  • Service 22DID 10A7
  • Module700 → 708
  • Every1 s
  • Testing for 2016 to 2018, 2020 to 2022, 2026

Example reply from a 2025 Toyota C-HR.

Bits 24 to 31 of the reply, 8 bits.

0x00 = 0 → 0

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2019, 2023 to 2025. In testing for 2016 to 2018, 2020 to 2022, 2026.

Misfire load CHR_MISFIRE_LOADConfirmed

  • Request22 10 AA
  • Service 22DID 10AA
  • Module700 → 708
  • Every1 s
  • Testing for 2016 to 2018, 2020 to 2022, 2026

Example reply from a 2025 Toyota C-HR.

Bits 0 to 7 of the reply, 8 bits.

0x00 = 0 → (0 × 510 ÷ 255) = 0 %

Formula
(val × 510 ÷ 255)
Range
0 to 510 %
Unit
%

Confirmed for 2019, 2023 to 2025. In testing for 2016 to 2018, 2020 to 2022, 2026.

Misfire margin CHR_MISFIRE_MARGIN

  • Request22 10 AA
  • Service 22DID 10AA
  • Module700 → 708
  • Every1 s
  • Testing for 2016 to 2018, 2020 to 2022, 2026

Bits 32 to 39 of the reply, 8 bits.

Formula
(val − 128)
Range
-128 to 127 rpm
Unit
rpm

In testing for 2016 to 2018, 2020 to 2022, 2026. Supported for 2019, 2023 to 2025.

Misfire RPM CHR_MISFIRE_RPM

  • Request22 10 AA
  • Service 22DID 10AA
  • Module700 → 708
  • Every1 s
  • Testing for 2016 to 2018, 2020 to 2022, 2026

Bits 24 to 31 of the reply, 8 bits.

Formula
(val × 6375 ÷ 255)
Range
0 to 6375 rpm
Unit
rpm

In testing for 2016 to 2018, 2020 to 2022, 2026. Supported for 2019, 2023 to 2025.

Misfire RPM CHR_MISFIRE_RPM_7E0

  • Request21 45
  • Service 21PID 45
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
(val × 25)
Range
0 to 6375 rpm
Unit
rpm

In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2019, 2024.

Misfire test result, incomplete CHR_MIS_TEST_RESULT

  • Request21 E3
  • Service 21PID E3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2016 to 2026.

Model year CHR_MODEL_YEAR

  • Request21 C1
  • Service 21PID C1
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 128 to 135 of the reply, 8 bits.

Formula
(val + 1900)
Range
1900 to 2155
Unit
Number

In testing for 2016 to 2026.

Motor inverter temperature CHR_MOTOR_INVERTER_T

  • Request22 10 A5
  • Service 22DID 10A5
  • Module7D2 → 7DA
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2019 to 2026.

Motor inverter temperature after ignition on CHR_MOTOR_INVERTER_T_ON

  • Request22 10 A5
  • Service 22DID 10A5
  • Module7D2 → 7DA
  • Every5 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2019 to 2026.

Motor inverter, maximum temperature CHR_M_INVRT_MAX_T

  • Request22 10 A6
  • Service 22DID 10A6
  • Module7D2 → 7DA
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2020 to 2022, 2026. Not supported for 2019, 2023 to 2025.

Motor regenerative brake torque CHR_MOTOR_REGENERATIVE_BREAK

  • Request22 10 69
  • Service 22DID 1069
  • Module7D2 → 7DA
  • Every250 ms
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
(val ÷ 8 − 4096)
Range
-4096 to 4095 kW
Unit
kW

In testing for 2019 to 2026.

Motor regenerative brake torque, requested CHR_MOTOR_REGENERATIVE

  • Request22 10 69
  • Service 22DID 1069
  • Module7D2 → 7DA
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 8 − 4096)
Range
-4096 to 4095 kW
Unit
kW

In testing for 2019 to 2026.

Motor RPM CHR_RPMConfirmed

  • Request22 10 A1
  • Service 22DID 10A1
  • Module7D2 → 7DA
  • Every250 ms
  • Testing for 2020 to 2022, 2026

Example reply from a 2025 Toyota C-HR.

Bits 0 to 15 of the reply, 16 bits.

0x8000 = 32768 → (32768 − 32768) = 0 rpm

Formula
(val − 32768)
Range
-32768 to 32767 rpm
Unit
rpm

Confirmed for 2019, 2023 to 2025. In testing for 2020 to 2022, 2026.

Motor torque CHR_TQConfirmed

  • Request22 10 A1
  • Service 22DID 10A1
  • Module7D2 → 7DA
  • Every250 ms
  • Testing for 2020 to 2022, 2026

Example reply from a 2025 Toyota C-HR.

Bits 48 to 63 of the reply, 16 bits.

0x7FFE = 32766 → (32766 ÷ 8 − 4096) = -0.25 N·m

Formula
(val ÷ 8 − 4096)
Range
-4096 to 4095 N·m
Unit
N·m

Confirmed for 2019, 2023 to 2025. In testing for 2020 to 2022, 2026.

O2 heater b1s2_active CHR_O2_HEATER_B1S2

  • Request21 3A
  • Service 21PID 3A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 68 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2016 to 2026.

O2 heater current val bank 1 sensor 2 CHR_O2_HEATER_CURR_VAL

  • Request21 3A
  • Service 21PID 3A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
(val ÷ 13107)
Range
0 to 4.999 A
Unit
A

In testing for 2016 to 2026.

Open side malfunction on CHR_OPEN_SIDE_ON

  • Request21 41
  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bit 145 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2016 to 2026.

Output shaft speed CHR_SPD_NOUT

  • Request21 81
  • Service 21PID 81
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
(val × 50)
Range
0 to 12750 rpm
Unit
rpm

In testing for 2016 to 2026.

OXS1, A/FS2 test result, incomplete CHR_OXS1_FS2_TEST_RESULT

  • Request21 E3
  • Service 21PID E3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2016 to 2026.

Oxygen sensor voltage, bank 1 sensor 1 CHR_O2S11_V

  • Request21 14
  • Service 21PID 14
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 0.0049960784)
Range
0 to 1.27 V
Unit
V

In testing for 2016 to 2026.

Oxygen sensor voltage, bank 1 sensor 2 CHR_O2S_B1S2

  • Request21 04
  • Service 21PID 04
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 144 to 151 of the reply, 8 bits.

Formula
(val × 5 ÷ 1000)
Range
0 to 1.275 V
Unit
V

In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2019, 2024.

PM accumulation ratio - bank 1 CHR_PM_ACCUMULATION_RAT_1

  • Request22 11 05
  • Service 22DID 1105
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 2)
Range
0 to 15 %
Unit
%

In testing for 2016 to 2026.

Purge cut vacuum switching valve duty CHR_PURGE_CUT_VSV_DUTY

  • Request21 3A
  • Service 21PID 3A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
(val × 25 ÷ 4096)
Range
0 to 399.9 %
Unit
%

In testing for 2016 to 2026.

Racing operation CHR_RACING_OPERATION

  • Request21 49
  • Service 21PID 49
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bit 90 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2016 to 2026.

Rear motor inverter, coolant temperature CHR_RM_INVRT_COOL_T

  • Request22 10 A6
  • Service 22DID 10A6
  • Module7D2 → 7DA
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2020 to 2022, 2026. Not supported for 2019, 2023 to 2025.

Rear motor regenerative brake torque CHR_REAR_MOTOR_REGENERATIVE

  • Request22 10 6A
  • Service 22DID 106A
  • Module7D2 → 7DA
  • Every250 ms
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
(val ÷ 8 − 4096)
Range
-4096 to 4095 kW
Unit
kW

In testing for 2019 to 2026.

Rear motor regenerative brake torque, requested CHR_REAR_MOTOR

  • Request22 10 6A
  • Service 22DID 106A
  • Module7D2 → 7DA
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 8 − 4096)
Range
-4096 to 4095 kW
Unit
kW

In testing for 2019 to 2026.

Rear motor speed CHR_RM_TQ_REQ

  • Request22 10 A2
  • Service 22DID 10A2
  • Module7D2 → 7DA
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val − 32768)
Range
-32768 to 32767 rpm
Unit
rpm

In testing for 2020 to 2022, 2026. Not supported for 2019, 2023 to 2025.

Rear motor torque CHR_RM_TQ

  • Request22 10 A2
  • Service 22DID 10A2
  • Module7D2 → 7DA
  • Every250 ms
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
(val ÷ 8 − 4096)
Range
-4096 to 4095 N·m
Unit
N·m

In testing for 2020 to 2022, 2026. Not supported for 2019, 2023 to 2025.

Regulator pressure CHR_REGULATOR_PConfirmed

  • Request21 53
  • Service 21PID 53
  • Module7C4 → 7CC
  • Every5 s
  • Testing for 2016 to 2018, 2020 to 2026

Example reply from a 2019 Toyota C-HR.

Bits 0 to 7 of the reply, 8 bits.

0x33 = 51 → (51 × 375105 ÷ 25500 − 456.68) = 293.53 kPa

Formula
(val × 375105 ÷ 25500 − 456.68)
Range
-456.68 to 3294 kPa
Unit
kPa

Confirmed for 2019. In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2024.

Request engine run time CHR_REQ_ENG_RUN_TIME

  • Request21 49
  • Service 21PID 49
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 48 to 55 of the reply, 8 bits.

Formula
(val ÷ 10)
Range
0 to 25.5 s
Unit
s

In testing for 2016 to 2026.

Request warm-up CHR_REQ_WARM_UP

  • Request21 49
  • Service 21PID 49
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bit 89 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2016 to 2026.

Requested engine torque CHR_REQ_ENG_TQ

  • Request21 49
  • Service 21PID 49
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 4)
Range
0 to 16383
Unit
Number

In testing for 2016 to 2026.

Rough idle, cylinder 1 CHR_ROUGH_IDLE_CYL_1

  • Request22 10 84
  • Service 22DID 1084
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 °
Unit
°

In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2019, 2024.

Rough idle, cylinder 2 CHR_ROUGH_IDLE_CYL_2

  • Request22 10 84
  • Service 22DID 1084
  • Module700 → 708
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255 °
Unit
°

In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2019, 2024.

Rough idle, cylinder 3 CHR_ROUGH_IDLE_CYL_3

  • Request22 10 84
  • Service 22DID 1084
  • Module700 → 708
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val
Range
0 to 255 °
Unit
°

In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2019, 2024.

Rough idle, cylinder 4 CHR_ROUGH_IDLE_CYL_4

  • Request22 10 84
  • Service 22DID 1084
  • Module700 → 708
  • Every1 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val
Range
0 to 255 °
Unit
°

In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2019, 2024.

Short term fuel trim, bank 1 CHR_SHORT_FT_B1

Pelican can show this parameter as the short term fuel trim.

  • Request21 03
  • Service 21PID 03
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
(val × 200 ÷ 256 − 100)
Range
-100 to 99.21 %
Unit
%

In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2019, 2024.

Short term fuel trim, bank 2 CHR_SHORT_FT_B2

Pelican can show this parameter as the short term fuel trim.

  • Request21 03
  • Service 21PID 03
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
(val × 200 ÷ 256 − 100)
Range
-100 to 99.21 %
Unit
%

In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2019, 2024.

Starter relay on CHR_STARTER_RELAY_ON

  • Request21 39
  • Service 21PID 39
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bit 47 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2016 to 2026.

Stroke open CHR_STROKE_OPENConfirmed

  • Request21 BE
  • Service 21PID BE
  • Module7B0 → 7B8
  • Every1 s
  • Testing for 2016 to 2018, 2020 to 2026

Example reply from a 2019 Toyota C-HR.

Bit 10 of the reply.

0b0 = 0 → 0

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2019. In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2024.

System guard on CHR_SYSTEM_GUARD_ON

  • Request21 41
  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bit 144 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2016 to 2026.

Throttle fully close learn CHR_THROTTLE_FULLY_CLOSE

  • Request21 41
  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 112 to 119 of the reply, 8 bits.

Formula
(val × 5 ÷ 256)
Range
0 to 4.98 V
Unit
V

In testing for 2016 to 2026.

Throttle idle position on CHR_THROTTLE_IDLE_POS_ON

  • Request21 41
  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bit 149 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2016 to 2026.

Throttle motor current CHR_THROTTLE_MOTOR

  • Request21 41
  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 136 to 143 of the reply, 8 bits.

Formula
(val × 5 ÷ 64)
Range
0 to 19.9 A
Unit
A

In testing for 2016 to 2026.

Throttle motor duty, close CHR_THROTTLE_MOTOR_DUTY_CLOSE

  • Request21 41
  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 128 to 135 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2016 to 2026.

Throttle motor duty, open CHR_THROTTLE_MOTOR_DUTY_OPEN

  • Request21 41
  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 120 to 127 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2016 to 2026.

Throttle position CHR_THROTTLE_21

  • Request21 11
  • Service 21PID 11
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 20 ÷ 51)
Range
0 to 100 %
Unit
%

In testing for 2016 to 2026.

Throttle position command CHR_THROTTLE_POS_COMMAND

  • Request21 41
  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
(val × 5 ÷ 256)
Range
0 to 4.98 V
Unit
V

In testing for 2016 to 2026.

Throttle position, number 1 CHR_THROTTLE_POS_NUMBER_1

  • Request21 41
  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 88 to 95 of the reply, 8 bits.

Formula
(val × 5 ÷ 256)
Range
0 to 4.98 V
Unit
V

In testing for 2016 to 2026.

Throttle position, number 2 CHR_THROTTLE_POS_NUMBER_2

  • Request21 41
  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 96 to 103 of the reply, 8 bits.

Formula
(val × 5 ÷ 256)
Range
0 to 4.98 V
Unit
V

In testing for 2016 to 2026.

Throttle require position CHR_THROTTLE_REQUIRE_POS

  • Request21 41
  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 104 to 111 of the reply, 8 bits.

Formula
(val × 5 ÷ 256)
Range
0 to 4.98 V
Unit
V

In testing for 2016 to 2026.

Throttle sensor open position 1 CHR_THROTTLE_SENS_OPEN_1

  • Request21 41
  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 5 ÷ 256)
Range
0 to 4.98 V
Unit
V

In testing for 2016 to 2026.

Throttle sensor open position 2 CHR_THROTTLE_SENS_OPEN_2

  • Request21 41
  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
(val × 5 ÷ 256)
Range
0 to 4.98 V
Unit
V

In testing for 2016 to 2026.

Total fuel trim, bank 1 CHR_TOT_FT_1

  • Request21 3C
  • Service 21PID 3C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
(val × 100 ÷ 256 − 50)
Range
-50 to 49.6 %
Unit
%

In testing for 2016 to 2026.

Transaxle oil temperature CHR_TRANSAXLE_OIL_TConfirmed

  • Request22 10 40
  • Service 22DID 1040
  • Module7D2 → 7DA
  • Every1 s
  • Testing for 2020 to 2022, 2024 to 2026

Example reply from a 2023 Toyota C-HR.

Bits 16 to 23 of the reply, 8 bits.

0x4D = 77 → (77 − 40) = 37 °C

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2019, 2023. In testing for 2020 to 2022, 2026. Not supported for 2024 to 2025.

Transmission fluid temperature CHR_ATF_TEMP_700

Pelican can show this parameter as the transmission fluid temperature.

  • Request22 16 38
  • Service 22DID 1638
  • Module700 → 708
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2016 to 2018, 2020 to 2021, 2026. Not supported for 2019, 2022 to 2025.

Transmission output shaft speed CHR_TRANS_OUT_RPM

  • Request21 BD
  • Service 21PID BD
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 50)
Range
0 to 12750 rpm
Unit
rpm

In testing for 2016 to 2026.

Turbine speed CHR_SPD_NT

  • Request21 81
  • Service 21PID 81
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 50)
Range
0 to 12750 rpm
Unit
rpm

In testing for 2016 to 2026.

Valvematic current angle CHR_VALVEMATIC_CURRENT

  • Request21 31
  • Service 21PID 31
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 5 ÷ 512)
Range
0 to 639.9 °
Unit
°

In testing for 2016 to 2026.

Valvematic, target angle CHR_VALVEMATIC_TGT_ANG

  • Request21 3A
  • Service 21PID 3A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 5 ÷ 512)
Range
0 to 639.9 °
Unit
°

In testing for 2016 to 2026.

Variable valve timing aim angle 1 CHR_VARIABLE_VLV_TIM_AIM_1

  • Request21 44
  • Service 21PID 44
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 1333 ÷ 218450)
Range
0 to 399 %
Unit
%

In testing for 2016 to 2026.

Variable valve timing change angle 1 CHR_VARIABLE_VLV_TIM_1

  • Request21 44
  • Service 21PID 44
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
(val × 0.0097642481)
Range
0 to 639 °
Unit
°

In testing for 2016 to 2026.

Variable valve timing control status 1 on CHR_VARIABLE_VLV_TIM_1_ON

  • Request21 39
  • Service 21PID 39
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bit 22 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2016 to 2026.

Variable valve timing oil control valve duty 1 CHR_VARIABLE_VLV_TIM_OIL_1

  • Request21 44
  • Service 21PID 44
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
(val × 0.0061020829)
Range
0 to 399 %
Unit
%

In testing for 2016 to 2026.

Variable valve timing oil temperature CHR_VVTOTConfirmed

  • Request21 51
  • Service 21PID 51
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2016 to 2018, 2020 to 2026

Example reply from a 2019 Toyota C-HR.

Bits 56 to 63 of the reply, 8 bits.

0x6A = 106 → (106 − 40) = 66 °C

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2019. In testing for 2016 to 2018, 2020 to 2021, 2026. Not supported for 2022 to 2025.

Variable valve timing opening angle bank 1 CHR_VVT_IE_OPENING_ANGLE_BANK_1Confirmed

  • Request22 28 43
  • Service 22DID 2843
  • Module700 → 708
  • Every1 s
  • Testing for 2016 to 2023, 2025 to 2026

Example reply from a 2024 Toyota C-HR.

Bits 0 to 7 of the reply, 8 bits.

0x00 = 0 → 0 %

Formula
val
Range
0 to 255 %
Unit
%

Confirmed for 2024. In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2019.

Vehicle speed CHR_VSS_21

  • Request21 0D
  • Service 21PID 0D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2016 to 2026.

Vehicle speed sensor test result, incomplete CHR_SPD_TEST_RESULT

  • Request21 E3
  • Service 21PID E3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2016 to 2026.

Engine › Catalyst

Catalyst temperature, bank 1 sensor 1 CHR_CAT_T_11Confirmed

  • Request22 1F 3C
  • Service 22DID 1F3C
  • Module700 → 708
  • Every5 s
  • Testing for 2016 to 2018, 2020 to 2022, 2026

Example reply from a 2025 Toyota C-HR.

Bits 0 to 15 of the reply, 16 bits.

0x0446 = 1094 → (1094 ÷ 10 − 40) = 69.4 °C

Formula
(val ÷ 10 − 40)
Range
-40 to 6513.5 °C
Unit
°C

Confirmed for 2019, 2023 to 2025. In testing for 2016 to 2018, 2020 to 2022, 2026.

Catalyst temperature, bank 1 sensor 2 CHR_CAT_T_12Confirmed

  • Request22 1F 3E
  • Service 22DID 1F3E
  • Module700 → 708
  • Every5 s
  • Testing for 2016 to 2018, 2020 to 2022, 2026

Example reply from a 2025 Toyota C-HR.

Bits 0 to 15 of the reply, 16 bits.

0x02D7 = 727 → (727 ÷ 10 − 40) = 32.7 °C

Formula
(val ÷ 10 − 40)
Range
-40 to 6513.5 °C
Unit
°C

Confirmed for 2019, 2023 to 2025. In testing for 2016 to 2018, 2020 to 2022, 2026.

Engine › Misfires

All cylinders misfire count CHR_ALL_CYLINDERS_MISFIRE_CNT

  • Request21 45
  • Service 21PID 45
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 56 to 63 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2019, 2024.

Cylinder #1 misfire count CHR_CYL1_MISFIRE_CNT

  • Request21 45
  • Service 21PID 45
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2019, 2024.

Cylinder #2 misfire count CHR_CYL2_MISFIRE_CNT

  • Request21 45
  • Service 21PID 45
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2019, 2024.

Cylinder #3 misfire count CHR_CYL3_MISFIRE_CNT

  • Request21 45
  • Service 21PID 45
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2019, 2024.

Cylinder #4 misfire count CHR_CYL4_MISFIRE_CNT

  • Request21 45
  • Service 21PID 45
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 48 to 55 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2019, 2024.

Misfire load CHR_MISFIRE_LOAD_7E0

  • Request21 45
  • Service 21PID 45
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
(val × 4 ÷ 256)
Range
0 to 3.98
Unit
Number

In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2019, 2024.

Misfire margin CHR_MISFIRE_MARGIN_7E0

  • Request21 45
  • Service 21PID 45
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 80 to 87 of the reply, 8 bits.

Formula
(val − 128)
Range
-128 to 127 %
Unit
%

In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2019, 2024.

Keyboard shortcuts

jk/↓↑
Move down or up through a list or a grid.
hl/←→
Move across a row or between cards.
Enter
Open the focused link.
f
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.