DTC parameters
The Suzuki Swift has 24 DTC parameters.
● Confirmed◆ In testing○ Supported× Not supported
2nd air monitor_avail SUZUKI_2ND_AIR_MONITOR_AVAIL
- Request
21 06 - Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 20 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 1988 to 2008, 2010 to 2018, 2021 to 2023, 2025 to 2026. Not supported for 2009, 2019 to 2020, 2024.
2nd air monitor_incmpl SUZUKI_2ND_AIR_MONITOR_INCMPL
- Request
21 06 - Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 28 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 1988 to 2008, 2010 to 2018, 2021 to 2023, 2025 to 2026. Not supported for 2009, 2019 to 2020, 2024.
A/C monitor_avail SUZUKI_A_C_MONITOR_AVAIL
- Request
21 06 - Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 19 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 1988 to 2008, 2010 to 2018, 2021 to 2023, 2025 to 2026. Not supported for 2009, 2019 to 2020, 2024.
A/C monitor_incmpl SUZUKI_A_C_MONITOR_INCMPL
- Request
21 06 - Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 27 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 1988 to 2008, 2010 to 2018, 2021 to 2023, 2025 to 2026. Not supported for 2009, 2019 to 2020, 2024.
Catalyst monitor_avail SUZUKI_CATALYST_MONITOR_AVAIL
- Request
21 06 - Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 23 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 1988 to 2008, 2010 to 2018, 2021 to 2023, 2025 to 2026. Not supported for 2009, 2019 to 2020, 2024.
Catalyst monitor_incmpl SUZUKI_CATALYST_MONITOR_INCMPL
- Request
21 06 - Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 31 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 1988 to 2008, 2010 to 2018, 2021 to 2023, 2025 to 2026. Not supported for 2009, 2019 to 2020, 2024.
Complete parts monitor_avail SUZUKI_COMPLETE_PARTS_MONITOR_AVAIL
- Request
21 06 - Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 13 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 1988 to 2008, 2010 to 2018, 2021 to 2023, 2025 to 2026. Not supported for 2009, 2019 to 2020, 2024.
Distance traveled since diagnostic trouble codes cleared CLR_DISTSAE J1979Confirmed
Distance accumulated since DTCs were cleared (via an external test equipment or possibly, a battery disconnect). This parameter is not associated with any particular DTC. It is simply an indication for inspection/maintenance, of the last time an external test equipment was used to clear DTCs. If greater than 65,535 km have occurred, will remain at 65,535 km and not wrap to zero.
Pelican can show this parameter as the distance since trouble codes were cleared.
- Request
01 31 - Service 01
PID 31 - Module
7E0 → 7E8 - Every
15 s
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 km
- Unit
- km
Confirmed for 2024. Supported for 2018 to 2020, 2025.
EGR/VVT monitor_avail SUZUKI_EGR_VVT_MONITOR_AVAIL
- Request
21 06 - Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 16 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 1988 to 2008, 2010 to 2018, 2021 to 2023, 2025 to 2026. Not supported for 2009, 2019 to 2020, 2024.
EGR/VVT monitor_incmpl SUZUKI_EGR_VVT_MONITOR_INCMPL
- Request
21 06 - Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 24 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 1988 to 2008, 2010 to 2018, 2021 to 2023, 2025 to 2026. Not supported for 2009, 2019 to 2020, 2024.
EVAP monitor_avail SUZUKI_EVAP_MONITOR_AVAIL
- Request
21 06 - Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 21 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 1988 to 2008, 2010 to 2018, 2021 to 2023, 2025 to 2026. Not supported for 2009, 2019 to 2020, 2024.
EVAP monitor_icmpl SUZUKI_EVAP_MONITOR_ICMPL
- Request
21 06 - Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 29 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 1988 to 2008, 2010 to 2018, 2021 to 2023, 2025 to 2026. Not supported for 2009, 2019 to 2020, 2024.
Fuel system monitor_avail SUZUKI_FUEL_SYSTEM_MONITOR_AVAIL
- Request
21 06 - Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 14 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 1988 to 2008, 2010 to 2018, 2021 to 2023, 2025 to 2026. Not supported for 2009, 2019 to 2020, 2024.
Heated catalyst monitor_avail SUZUKI_HEATED_CATALYST_MONITOR_AVAIL
- Request
21 06 - Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 22 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 1988 to 2008, 2010 to 2018, 2021 to 2023, 2025 to 2026. Not supported for 2009, 2019 to 2020, 2024.
Heated catalyst monitor_incmpl SUZUKI_HEATED_CATALYST_MONITOR_INCMPL
- Request
21 06 - Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 30 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 1988 to 2008, 2010 to 2018, 2021 to 2023, 2025 to 2026. Not supported for 2009, 2019 to 2020, 2024.
MIL SUZUKI_MIL
- Request
21 06 - Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 0 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 1988 to 2008, 2010 to 2018, 2021 to 2023, 2025 to 2026. Not supported for 2009, 2019 to 2020, 2024.
MIL ON run distance SUZUKI_MILON_RUN_DISTANCE
- Request
21 06 - Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 48 to 63 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 km
- Unit
- km
In testing for 1988 to 2008, 2010 to 2018, 2021 to 2023, 2025 to 2026. Not supported for 2009, 2019 to 2020, 2024.
Misfire monitor_avail SUZUKI_MISFIRE_MONITOR_AVAIL
- Request
21 06 - Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 15 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 1988 to 2008, 2010 to 2018, 2021 to 2023, 2025 to 2026. Not supported for 2009, 2019 to 2020, 2024.
Number of emission DTC SUZUKI_NUMBER_OF_EMISSION_DTC
- Request
21 06 - Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 1 to 7 of the reply, 7 bits.
- Formula
val- Range
- 0 to 127
- Unit
- Number
In testing for 1988 to 2008, 2010 to 2018, 2021 to 2023, 2025 to 2026. Not supported for 2009, 2019 to 2020, 2024.
O2S heater monitor_avail SUZUKI_O2S_A_FS_HEATER_MONITOR_AVAIL
- Request
21 06 - Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 17 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 1988 to 2008, 2010 to 2018, 2021 to 2023, 2025 to 2026. Not supported for 2009, 2019 to 2020, 2024.
O2S heater monitor_incmpl SUZUKI_O2S_A_FS_HEATER_MONITOR_INCMPL
- Request
21 06 - Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 25 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 1988 to 2008, 2010 to 2018, 2021 to 2023, 2025 to 2026. Not supported for 2009, 2019 to 2020, 2024.
O2S monitor_avail SUZUKI_O2S_A_FS_MONITOR_AVAIL
- Request
21 06 - Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 18 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 1988 to 2008, 2010 to 2018, 2021 to 2023, 2025 to 2026. Not supported for 2009, 2019 to 2020, 2024.
O2S monitor_incmpl SUZUKI_O2S_A_FS_MONITOR_INCMPL
- Request
21 06 - Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 26 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 1988 to 2008, 2010 to 2018, 2021 to 2023, 2025 to 2026. Not supported for 2009, 2019 to 2020, 2024.
Running time from MIL ON SUZUKI_RUNNING_TIME_FROM_MIL_ON
- Request
21 06 - Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 min
- Unit
- min
In testing for 1988 to 2008, 2010 to 2018, 2021 to 2023, 2025 to 2026. Not supported for 2009, 2019 to 2020, 2024.