Climate parameters
The Suzuki Swift has 30 climate parameters.
● Confirmed◆ In testing○ Supported× Not supported
Adjusted ambient temperature SUZUKI_ADJUSTED_AMBIENT_T
- Request
21 3D - Service 21
PID 3D - Module
7C4 → 7CC - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 81.6 ÷ 255 − 30.8)- Range
- -30.8 to 50.8 °C
- Unit
- °C
In testing for 1988 to 2006, 2008, 2010 to 2018, 2021 to 2023, 2025 to 2026. Not supported for 2007, 2009, 2019 to 2020, 2024.
Air conditioner feedback SUZUKI_AC_FB
- Request
21 51 - Service 21
PID 51 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 216 to 231 of the reply, 16 bits.
- Formula
(val × 10 ÷ 8192 − 40)- Range
- -40 to 39.99
- Unit
- Number
In testing for 1988 to 2006, 2008, 2010 to 2018, 2021 to 2023, 2025 to 2026. Not supported for 2007, 2009, 2019 to 2020, 2024.
Air conditioning inverter gate SUZUKI_AC_GATE
- Request
21 C4 - Service 21
PID C4 - Module
7E2 - Every
250 ms - Testing
Bit 67 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 1988 to 2019, 2021 to 2023, 2025 to 2026. Not supported for 2020, 2024.
Air conditioning power consumption SUZUKI_AC_PWR
- Request
21 C4 - Service 21
PID C4 - Module
7E2 - Every
250 ms - Testing
Bits 120 to 127 of the reply, 8 bits.
- Formula
(val ÷ 51)- Range
- 0 to 5 kW
- Unit
- kW
In testing for 1988 to 2019, 2021 to 2023, 2025 to 2026. Not supported for 2020, 2024.
Air conditioning requested SUZUKI_AC_REQ
- Request
21 C4 - Service 21
PID C4 - Module
7E2 - Every
250 ms - Testing
Bit 14 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 1988 to 2019, 2021 to 2023, 2025 to 2026. Not supported for 2020, 2024.
Air inlet damper actual pulse SUZUKI_AIR_INLET_DAMPER_ACTUAL_PULSE
- Request
21 44 - Service 21
PID 44 - Module
7C4 - Every
1 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 2006, 2008, 2010 to 2018, 2021 to 2023, 2025 to 2026. Not supported for 2007, 2009, 2019 to 2020, 2024.
Air inlet damper target pulse SUZUKI_AIR_INLET_DAMPER_TARGET_PULSE
- Request
21 44 - Service 21
PID 44 - Module
7C4 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 2006, 2008, 2010 to 2018, 2021 to 2023, 2025 to 2026. Not supported for 2007, 2009, 2019 to 2020, 2024.
Air outlet servo actual pulse, driver SUZUKI_AIR_OUTLET_SERVO_ACTU_PULSE_D
- Request
21 43 - Service 21
PID 43 - Module
7C4 - Every
1 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 2006, 2008, 2010 to 2018, 2021 to 2023, 2025 to 2026. Not supported for 2007, 2009, 2019 to 2020, 2024.
Air outlet servo pulse, driver SUZUKI_AIR_OUTLET_SERVO_PULSE_D
- Request
21 43 - Service 21
PID 43 - Module
7C4 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 2006, 2008, 2010 to 2018, 2021 to 2023, 2025 to 2026. Not supported for 2007, 2009, 2019 to 2020, 2024.
Ambient air temperature SUZUKI_AAT_7C4
- Request
21 22 - Service 21
PID 22 - Module
7C4 → 7CC - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 89.25 ÷ 255 − 23.3)- Range
- -23.3 to 65.95 °C
- Unit
- °C
In testing for 1988 to 2006, 2008, 2010 to 2018, 2021 to 2023, 2025 to 2026. Not supported for 2007, 2009, 2019 to 2020, 2024.
Ambient temperature SUZUKI_AMBIENT_T
- Request
22 1F 46 - Service 22
DID 1F46 - Module
700 → 708 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 1988 to 2006, 2008, 2010 to 2018, 2021 to 2023, 2025 to 2026. Not supported for 2007, 2009, 2019 to 2020, 2024.
Ambient temperature for A/C SUZUKI_AC_AMB_T
- Request
21 51 - Service 21
PID 51 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 88 to 95 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 1988 to 2006, 2008, 2010 to 2018, 2021 to 2023, 2025 to 2026. Not supported for 2007, 2009, 2019 to 2020, 2024.
Ambient temperature, climate SUZUKI_AAT_7C4_V2
- Request
22 10 02 - Service 22
DID 1002 - Module
7C4 → 7CC - Every
10 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -327.68 to 327.67 °C
- Unit
- °C
In testing for 1988 to 2019, 2021 to 2023, 2025 to 2026. Not supported for 2020, 2024.
Blower level SUZUKI_BLOWER
- Request
22 28 01 - Service 22
DID 2801 - Module
7C4 → 7CC - Every
10 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 7
- Unit
- Number
In testing for 1988 to 2019, 2021 to 2023, 2025 to 2026. Not supported for 2020, 2024.
Blower motor speed level SUZUKI_BLOWER_MOTOR_SPEED_LEVEL
- Request
21 3C - Service 21
PID 3C - Module
7C4 → 7CC - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 2006, 2008, 2010 to 2018, 2021 to 2023, 2025 to 2026. Not supported for 2007, 2009, 2019 to 2020, 2024.
Cabin mode active while parked SUZUKI_MY_ROOM
- Request
22 16 92 - Service 22
DID 1692 - Module
745 → 74D - Every
10 s - Testing
Bit 15 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
In testing for 1988 to 2019, 2021 to 2023, 2025 to 2026. Not supported for 2020, 2024.
Cabin temperature SUZUKI_CABIN_T
- Request
21 21 - Service 21
PID 21 - Module
7C4 → 7CC - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 63.75 ÷ 255 − 6.5)- Range
- -6.5 to 57.25 °C
- Unit
- °C
In testing for 1988 to 2006, 2008, 2010 to 2018, 2021 to 2023, 2025 to 2026. Not supported for 2007, 2009, 2019 to 2020, 2024.
Cabin temperature SUZUKI_CABIN_T_V2
- Request
22 10 01 - Service 22
DID 1001 - Module
7C4 → 7CC - Every
10 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -327.68 to 327.67 °C
- Unit
- °C
In testing for 1988 to 2019, 2021 to 2023, 2025 to 2026. Not supported for 2020, 2024.
Climate control engine run requested SUZUKI_HVAC_REQ
- Request
21 C4 - Service 21
PID C4 - Module
7E2 - Every
250 ms - Testing
Bit 12 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 1988 to 2019, 2021 to 2023, 2025 to 2026. Not supported for 2020, 2024.
Climate power SUZUKI_HVAC_P
- Request
22 10 6E - Service 22
DID 106E - Module
7D2 → 7DA - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 20)- Range
- 0 to 12.75 kW
- Unit
- kW
In testing for 1988 to 2019, 2021 to 2023, 2025 to 2026. Not supported for 2020, 2024.
Climate power, charging control SUZUKI_HVAC_P_745
- Request
22 10 6E - Service 22
DID 106E - Module
745 → 74D - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 20)- Range
- 0 to 12.75 kW
- Unit
- kW
In testing for 1988 to 2019, 2021 to 2023, 2025 to 2026. Not supported for 2020, 2024.
Climate set point code SUZUKI_HVAC_SET_RAW
- Request
22 10 36 - Service 22
DID 1036 - Module
7C4 → 7CC - Every
10 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 2019, 2021 to 2023, 2025 to 2026. Not supported for 2020, 2024.
Communication with air conditioner SUZUKI_COMM_WITH_AIR_CONDITIONER
- Request
21 24 - Service 21
PID 24 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 5 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 1988 to 2006, 2008, 2010 to 2018, 2021 to 2023, 2025 to 2026. Not supported for 2007, 2009, 2019 to 2020, 2024.
Communication with HV SUZUKI_COMMUNICATION_WITH_HV
- Request
21 24 - Service 21
PID 24 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 2 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 1988 to 2006, 2008, 2010 to 2018, 2021 to 2023, 2025 to 2026. Not supported for 2007, 2009, 2019 to 2020, 2024.
Communication with valvematic SUZUKI_COMM_WITH_VALVEMATIC_COMM
- Request
21 24 - Service 21
PID 24 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 6 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1988 to 2006, 2008, 2010 to 2018, 2021 to 2023, 2025 to 2026. Not supported for 2007, 2009, 2019 to 2020, 2024.
Electric heater power count SUZUKI_HEATER_RAW
- Request
22 10 86 - Service 22
DID 1086 - Module
7C4 → 7CC - Every
10 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 1988 to 2019, 2021 to 2023, 2025 to 2026. Not supported for 2020, 2024.
Evaporator fin thermistor SUZUKI_EVAP_FIN_THERMISTOR
- Request
21 4B - Service 21
PID 4B - Module
7C4 → 7CC - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 89.25 ÷ 255 − 29.7)- Range
- -29.7 to 59.55 °C
- Unit
- °C
In testing for 1988 to 2006, 2008, 2010 to 2018, 2021 to 2023, 2025 to 2026. Not supported for 2007, 2009, 2019 to 2020, 2024.
Evaporator target temperature SUZUKI_EVAP_TARGET_T
- Request
21 4C - Service 21
PID 4C - Module
7C4 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100 − 327.68)- Range
- -327.68 to 327.67
- Unit
- Number
In testing for 1988 to 2006, 2008, 2010 to 2018, 2021 to 2023, 2025 to 2026. Not supported for 2007, 2009, 2019 to 2020, 2024.
Set temperature, driver side SUZUKI_T_DRIVER
- Request
21 29 - Service 21
PID 29 - Module
7C4 → 7CC - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 °C
- Unit
- °C
In testing for 1988 to 2006, 2008, 2010 to 2018, 2021 to 2023, 2025 to 2026. Not supported for 2007, 2009, 2019 to 2020, 2024.
Solar sensor, driver side SUZUKI_SOLAR_DRIVER
- Request
21 24 - Service 21
PID 24 - Module
7C4 → 7CC - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 2006, 2008, 2010 to 2018, 2021 to 2023, 2025 to 2026. Not supported for 2007, 2009, 2019 to 2020, 2024.