Connectable parameters
The smart fortwo has 9 Connectables, parameters that Pelican can monitor automatically.
● Confirmed◆ In testing○ Supported× Not supported
State of charge
HV battery state of charge FORTWO_EQA_HV_SOC
Pelican can show this parameter as the state of charge.
- Request
22 60 50 - Service 22
DID 6050 - Module
7E5 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 100 %
- Unit
- %
In testing for 1998 to 2024.
State of charge FORTWO_SOC
Pelican can show this parameter as the state of charge.
- Request
21 08 - Service 21
PID 08 - Module
79B → 7BB - Every
10 s - Testing
Bits 48 to 63 of the reply, 16 bits.
- Formula
(val ÷ 16)- Range
- 0 to 4095.9375 %
- Unit
- %
In testing for 1998 to 2024.
State of health
State of health FORTWO_SOH
Pelican can show this parameter as the state of health.
- Request
21 61 - Service 21
PID 61 - Module
79B → 7BB - Every
60 s - Testing
Bits 64 to 71 of the reply, 8 bits.
- Formula
(val ÷ 2)- Range
- 0 to 127.5 %
- Unit
- %
In testing for 1998 to 2024.
Plug state
Charging plug detected FORTWO_PLUG
Pelican can show this parameter as the plug state.
- Request
22 33 9D - Service 22
DID 339D - Module
7E4 → 7EC - Every
5 s - Testing
Bits 4 to 7 of the reply, 4 bits.
- Formula
val- Range
- 0 to 1
- Unit
- Yes or no
In testing for 1998 to 2024.
Electric range
HV battery remaining distance FORTWO_EQA_HV_RANGE
Pelican can show this parameter as the electric range.
- Request
22 65 02 - Service 22
DID 6502 - Module
7E5 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
val- Range
- 0 to 1000 km
- Unit
- km
In testing for 1998 to 2024.
Starter battery voltage
12V system voltage, hd FORTWO_EQA_AUX_V_HD
Pelican can show this parameter as the starter battery voltage.
- Request
22 02 01 - Service 22
DID 0201 - Module
624 → 5A4 - Every
1 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val × 1000 ÷ 10000)- Range
- 0 to 100 V
- Unit
- V
In testing for 1998 to 2024.
Auxiliary battery voltage FORTWO_EQA_AUX_V
Pelican can show this parameter as the starter battery voltage.
- Request
22 20 05 - Service 22
DID 2005 - Module
7E5 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 25.9 ÷ 255)- Range
- 0 to 25.9 V
- Unit
- V
In testing for 1998 to 2024.
Traction battery current
HV battery current FORTWO_HV_A
Pelican can show this parameter as the traction battery current.
- Request
21 07 - Service 21
PID 07 - Module
79B → 7BB - Every
5 s - Testing
Bits 80 to 95 of the reply, 16 bits. The value is signed.
- Formula
(val × -1 ÷ 32)- Range
- -1023.9687 to 1024 A
- Unit
- A
In testing for 1998 to 2024.
Traction battery voltage
HV battery voltage FORTWO_HV_V
Pelican can show this parameter as the traction battery voltage.
- Request
21 07 - Service 21
PID 07 - Module
79B → 7BB - Every
5 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
(val ÷ 64)- Range
- 0 to 1023.9843 V
- Unit
- V
In testing for 1998 to 2024.