smart fortwo

Battery parameters

The smart fortwo has 281 battery parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

12V system voltage, hd FORTWO_EQA_AUX_V_HD

Pelican can show this parameter as the starter battery voltage.

  • Request22 02 01
  • Service 22DID 0201
  • Module624 → 5A4
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
(val × 1000 ÷ 10000)
Range
0 to 100 V
Unit
V

In testing for 1998 to 2024.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

12V system voltage, hd FORTWO_EQA_AUX_V_HD

Pelican can show this parameter as the starter battery voltage.

  • Request22 02 01
  • Service 22DID 0201
  • Module624 → 5A4
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
(val × 1000 ÷ 10000)
Range
0 to 100 V
Unit
V

In testing for 1998 to 2024.

Auxiliary battery voltage FORTWO_EQA_AUX_V

Pelican can show this parameter as the starter battery voltage.

  • Request22 20 05
  • Service 22DID 2005
  • Module7E5
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 25.9 ÷ 255)
Range
0 to 25.9 V
Unit
V

In testing for 1998 to 2024.

Battery age condition FORTWO_ED_BAT_AGE

  • Request22 63 08
  • Service 22DID 6308
  • Module7E5 → 7ED
  • Every600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 2)
Range
0 to 127.5 %
Unit
%

In testing for 1998 to 2024.

Battery heater on FORTWO_ED_HEATER_ON

  • Request22 D3 02
  • Service 22DID D302
  • Module7E5 → 7ED
  • Every60 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 1998 to 2024.

Battery module 1 temperature FORTWO_ED_MOD_T1

  • Request22 02 02
  • Service 22DID 0202
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 64)
Range
-512 to 511.9843 °C
Unit
°C

In testing for 1998 to 2024.

Battery module 2 temperature FORTWO_ED_MOD_T2

  • Request22 02 02
  • Service 22DID 0202
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 16 to 31 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 64)
Range
-512 to 511.9843 °C
Unit
°C

In testing for 1998 to 2024.

Battery module 3 temperature FORTWO_ED_MOD_T3

  • Request22 02 02
  • Service 22DID 0202
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 32 to 47 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 64)
Range
-512 to 511.9843 °C
Unit
°C

In testing for 1998 to 2024.

Battery module 4 temperature FORTWO_ED_MOD_T4

  • Request22 02 02
  • Service 22DID 0202
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 48 to 63 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 64)
Range
-512 to 511.9843 °C
Unit
°C

In testing for 1998 to 2024.

Battery module 5 temperature FORTWO_ED_MOD_T5

  • Request22 02 02
  • Service 22DID 0202
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 64 to 79 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 64)
Range
-512 to 511.9843 °C
Unit
°C

In testing for 1998 to 2024.

Battery module 6 temperature FORTWO_ED_MOD_T6

  • Request22 02 02
  • Service 22DID 0202
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 80 to 95 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 64)
Range
-512 to 511.9843 °C
Unit
°C

In testing for 1998 to 2024.

Battery module 7 temperature FORTWO_ED_MOD_T7

  • Request22 02 02
  • Service 22DID 0202
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 96 to 111 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 64)
Range
-512 to 511.9843 °C
Unit
°C

In testing for 1998 to 2024.

Battery module 8 temperature FORTWO_ED_MOD_T8

  • Request22 02 02
  • Service 22DID 0202
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 112 to 127 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 64)
Range
-512 to 511.9843 °C
Unit
°C

In testing for 1998 to 2024.

Battery module 9 temperature FORTWO_ED_MOD_T9

  • Request22 02 02
  • Service 22DID 0202
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 128 to 143 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 64)
Range
-512 to 511.9843 °C
Unit
°C

In testing for 1998 to 2024.

Battery operating mode FORTWO_EV_MODE

  • Request21 07
  • Service 21PID 07
  • Module79B → 7BB
  • Every5 s
  • Testing

Bits 168 to 175 of the reply, 8 bits.

Formula
val
Range
0 to 7
Unit
Number

In testing for 1998 to 2024.

Capacity loss FORTWO_CAP_LOSS

  • Request21 08
  • Service 21PID 08
  • Module79B → 7BB
  • Every10 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
(val ÷ 16)
Range
0 to 4095.9375 %
Unit
%

In testing for 1998 to 2024.

Cell capacity, average FORTWO_ED_CAP_AS_AVG

  • Request22 03 10
  • Service 22DID 0310
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 152 to 167 of the reply, 16 bits.

Formula
(val ÷ 3600)
Range
0 to 18.2041 Ah
Unit
Ah

In testing for 1998 to 2024.

Cell capacity, maximum FORTWO_ED_CAP_AS_MAX

  • Request22 03 10
  • Service 22DID 0310
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 104 to 119 of the reply, 16 bits.

Formula
(val ÷ 3600)
Range
0 to 18.2041 Ah
Unit
Ah

In testing for 1998 to 2024.

Cell capacity, minimum FORTWO_ED_CAP_AS_MIN

  • Request22 03 10
  • Service 22DID 0310
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 136 to 151 of the reply, 16 bits.

Formula
(val ÷ 3600)
Range
0 to 18.2041 Ah
Unit
Ah

In testing for 1998 to 2024.

Cell voltage reference, average FORTWO_ED_ADC_V_AVG

  • Request22 02 07
  • Service 22DID 0207
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mV
Unit
mV

In testing for 1998 to 2024.

Cell voltage reference, maximum FORTWO_ED_ADC_V_MAX

  • Request22 02 07
  • Service 22DID 0207
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val + 1500)
Range
1500 to 67035 mV
Unit
mV

In testing for 1998 to 2024.

Cell voltage reference, minimum FORTWO_ED_ADC_V_MIN

  • Request22 02 07
  • Service 22DID 0207
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
(val + 1500)
Range
1500 to 67035 mV
Unit
mV

In testing for 1998 to 2024.

Charger 12V output voltage FORTWO_ED_OBL_LV

  • Request22 02 26
  • Service 22DID 0226
  • Module61A → 483
  • Every10 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
(val ÷ 10)
Range
0 to 25.5 V
Unit
V

In testing for 1998 to 2024.

Charger cooling plate temperature FORTWO_ED_OBL_PLATE_T

  • Request22 02 23
  • Service 22DID 0223
  • Module61A → 483
  • Every60 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 1998 to 2024.

Charger current set point FORTWO_ED_OBL_A_SET

  • Request22 02 2A
  • Service 22DID 022A
  • Module61A → 483
  • Every60 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val
Range
0 to 255 A
Unit
A

In testing for 1998 to 2024.

Charger HV output current FORTWO_ED_OBL_HV_A

  • Request22 02 25
  • Service 22DID 0225
  • Module61A → 483
  • Every10 s
  • Testing

Bits 112 to 127 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 204.7 A
Unit
A

In testing for 1998 to 2024.

Charger HV output voltage FORTWO_ED_OBL_HV

  • Request22 02 26
  • Service 22DID 0226
  • Module61A → 483
  • Every10 s
  • Testing

Bits 40 to 55 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 819 V
Unit
V

In testing for 1998 to 2024.

Charger mains current FORTWO_ED_OBL_MAINS_A

  • Request22 02 25
  • Service 22DID 0225
  • Module61A → 483
  • Every10 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 204.7 A
Unit
A

In testing for 1998 to 2024.

Charger mains current, phase 1 FORTWO_OBL_A1

  • Request22 73 03
  • Service 22DID 7303
  • Module792 → 793
  • Every10 s
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 5990.4 A
Unit
A

In testing for 1998 to 2024.

Charger mains current, phase 2 FORTWO_OBL_A2

  • Request22 73 03
  • Service 22DID 7303
  • Module792 → 793
  • Every10 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 5990.4 A
Unit
A

In testing for 1998 to 2024.

Charger mains voltage FORTWO_ED_OBL_MAINS_V

  • Request22 02 26
  • Service 22DID 0226
  • Module61A → 483
  • Every10 s
  • Testing

Bits 56 to 71 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 819 V
Unit
V

In testing for 1998 to 2024.

Charger mains voltage FORTWO_OBL_V

  • Request22 73 03
  • Service 22DID 7303
  • Module792 → 793
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 5990.4 V
Unit
V

In testing for 1998 to 2024.

Charger power 1 FORTWO_OBL_P1

  • Request22 73 03
  • Service 22DID 7303
  • Module792 → 793
  • Every10 s
  • Testing

Bits 96 to 111 of the reply, 16 bits.

Formula
(val ÷ 2000)
Range
0 to 29.952 kW
Unit
kW

In testing for 1998 to 2024.

Charger power 2 FORTWO_OBL_P2

  • Request22 73 03
  • Service 22DID 7303
  • Module792 → 793
  • Every10 s
  • Testing

Bits 112 to 127 of the reply, 16 bits.

Formula
(val ÷ 2000)
Range
0 to 29.952 kW
Unit
kW

In testing for 1998 to 2024.

Charger temperature FORTWO_ED_OBL_T

  • Request22 02 23
  • Service 22DID 0223
  • Module61A → 483
  • Every60 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 1998 to 2024.

Charging cable current code FORTWO_ED_OBL_CABLE_A

  • Request22 02 25
  • Service 22DID 0225
  • Module61A → 483
  • Every10 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 6553.5 A
Unit
A

In testing for 1998 to 2024.

Charging plug detected FORTWO_PLUG

Pelican can show this parameter as the plug state.

  • Request22 33 9D
  • Service 22DID 339D
  • Module7E4 → 7EC
  • Every5 s
  • Testing

Bits 4 to 7 of the reply, 4 bits.

Formula
val
Range
0 to 1
Unit
Yes or no

In testing for 1998 to 2024.

Charging socket temperature FORTWO_ED_OBL_SOCKET_T

  • Request22 02 23
  • Service 22DID 0223
  • Module61A → 483
  • Every60 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 1998 to 2024.

DC converter requested voltage FORTWO_EQA_CNVRTR_REQ_V

  • Request22 60 71
  • Service 22DID 6071
  • Module7E5
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 250 ÷ 10000)
Range
0 to 100 V
Unit
V

In testing for 1998 to 2024.

Estimated capacity FORTWO_CAP_EST

  • Request21 08
  • Service 21PID 08
  • Module79B → 7BB
  • Every10 s
  • Testing

Bits 96 to 111 of the reply, 16 bits.

Formula
(val ÷ 360)
Range
0 to 182.0416 Ah
Unit
Ah

In testing for 1998 to 2024.

Highest cell voltage FORTWO_CELL_V_MAX

  • Request21 07
  • Service 21PID 07
  • Module79B → 7BB
  • Every5 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 1998 to 2024.

HV battery amperage FORTWO_EQA_HV_A

  • Request22 60 53
  • Service 22DID 6053
  • Module7E5
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
0 to 100 A
Unit
A

In testing for 1998 to 2024.

HV battery available energy FORTWO_HV_E

  • Request22 32 0C
  • Service 22DID 320C
  • Module7E4 → 7EC
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 200)
Range
0 to 327.675 kWh
Unit
kWh

In testing for 1998 to 2024.

HV battery coolant temperature FORTWO_EQA_HV_COOLANT_T

  • Request22 25 26
  • Service 22DID 2526
  • Module7E5
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val × 1250 ÷ 10000)
Range
0 to 100 °C
Unit
°C

In testing for 1998 to 2024.

HV battery current FORTWO_ED_HV_A

  • Request22 02 03
  • Service 22DID 0203
  • Module7E7 → 7EF
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 32)
Range
-1024 to 1023.9687 A
Unit
A

In testing for 1998 to 2024.

HV battery current FORTWO_HV_A

Pelican can show this parameter as the traction battery current.

  • Request21 07
  • Service 21PID 07
  • Module79B → 7BB
  • Every5 s
  • Testing

Bits 80 to 95 of the reply, 16 bits. The value is signed.

Formula
(val × -1 ÷ 32)
Range
-1023.9687 to 1024 A
Unit
A

In testing for 1998 to 2024.

HV battery open-circuit voltage FORTWO_OCV

  • Request21 08
  • Service 21PID 08
  • Module79B → 7BB
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 655.35 V
Unit
V

In testing for 1998 to 2024.

HV battery state of charge FORTWO_EQA_HV_SOC

Pelican can show this parameter as the state of charge.

  • Request22 60 50
  • Service 22DID 6050
  • Module7E5
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 100 %
Unit
%

In testing for 1998 to 2024.

HV battery temperature FORTWO_ED_HV_T

  • Request22 02 01
  • Service 22DID 0201
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 64)
Range
-512 to 511.9843 °C
Unit
°C

In testing for 1998 to 2024.

HV battery temperature, average FORTWO_HV_T_AVG

  • Request21 04
  • Service 21PID 04
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 32 to 47 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 64)
Range
-512 to 511.9843 °C
Unit
°C

In testing for 1998 to 2024.

HV battery temperature, maximum FORTWO_HV_T_MAX

  • Request21 04
  • Service 21PID 04
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 16 to 31 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 64)
Range
-512 to 511.9843 °C
Unit
°C

In testing for 1998 to 2024.

HV battery temperature, minimum FORTWO_HV_T_MIN

  • Request21 04
  • Service 21PID 04
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 64)
Range
-512 to 511.9843 °C
Unit
°C

In testing for 1998 to 2024.

HV battery voltage FORTWO_ED_HV_V

  • Request22 02 04
  • Service 22DID 0204
  • Module7E7 → 7EF
  • Every10 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
(val ÷ 64)
Range
0 to 1023.9843 V
Unit
V

In testing for 1998 to 2024.

HV battery voltage FORTWO_EQA_HV_V

  • Request22 60 75
  • Service 22DID 6075
  • Module7E5
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 25 ÷ 1000)
Range
0 to 100 V
Unit
V

In testing for 1998 to 2024.

HV battery voltage FORTWO_HV_V

Pelican can show this parameter as the traction battery voltage.

  • Request21 07
  • Service 21PID 07
  • Module79B → 7BB
  • Every5 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
(val ÷ 64)
Range
0 to 1023.9843 V
Unit
V

In testing for 1998 to 2024.

HV contactor cycles remaining FORTWO_ED_CONT_LEFT

  • Request22 03 0B
  • Service 22DID 030B
  • Module7E7 → 7EF
  • Every600 s
  • Testing

Bits 8 to 31 of the reply, 24 bits.

Formula
val
Range
0 to 16777215
Unit
Number

In testing for 1998 to 2024.

HV contactor cycles remaining FORTWO_HV_CONT_LEFT

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 1998 to 2024.

HV contactor cycles, maximum FORTWO_ED_CONT_MAX

  • Request22 03 0C
  • Service 22DID 030C
  • Module7E7 → 7EF
  • Every600 s
  • Testing

Bits 8 to 31 of the reply, 24 bits.

Formula
val
Range
0 to 16777215
Unit
Number

In testing for 1998 to 2024.

HV contactor cycles, maximum FORTWO_HV_CONT_MAX

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 32 to 63 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 1998 to 2024.

HV contactor state FORTWO_ED_CONTACTOR

  • Request22 D0 00
  • Service 22DID D000
  • Module7E7 → 7EF
  • Every10 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1998 to 2024.

HV contactor state FORTWO_HV_CONTACTOR

  • Request21 07
  • Service 21PID 07
  • Module79B → 7BB
  • Every5 s
  • Testing

Bits 96 to 103 of the reply, 8 bits.

Formula
val
Range
0 to 3
Unit
Number

In testing for 1998 to 2024.

HV DC fault code FORTWO_ED_DC_FAULT

  • Request22 02 09
  • Service 22DID 0209
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1998 to 2024.

HV isolation resistance FORTWO_ED_ISO

  • Request22 02 09
  • Service 22DID 0209
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65534 kΩ
Unit
kΩ

In testing for 1998 to 2024.

HV plug interlock closed FORTWO_HV_INTERLOCK_PLUG

  • Request21 07
  • Service 21PID 07
  • Module79B → 7BB
  • Every5 s
  • Testing

Bits 104 to 111 of the reply, 8 bits.

Formula
val
Range
0 to 1
Unit
Yes or no

In testing for 1998 to 2024.

Initial capacity FORTWO_CAP_INIT

  • Request21 08
  • Service 21PID 08
  • Module79B → 7BB
  • Every10 s
  • Testing

Bits 80 to 95 of the reply, 16 bits.

Formula
(val ÷ 360)
Range
0 to 182.0416 Ah
Unit
Ah

In testing for 1998 to 2024.

Leakage current, 10 kilohertz FORTWO_LEAK_HF10

  • Request22 50 66
  • Service 22DID 5066
  • Module792 → 793
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000 − 32.768)
Range
-32.768 to 32.7669
Unit
Number

In testing for 1998 to 2024.

Leakage DC current FORTWO_LEAK_DC

  • Request22 50 65
  • Service 22DID 5065
  • Module792 → 793
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000 − 32.768)
Range
-32.768 to 32.7669
Unit
Number

In testing for 1998 to 2024.

Leakage diagnostic code FORTWO_LEAK_DIAG

  • Request22 50 64
  • Service 22DID 5064
  • Module792 → 793
  • Every60 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1998 to 2024.

Leakage high-frequency current FORTWO_LEAK_HF

  • Request22 50 67
  • Service 22DID 5067
  • Module792 → 793
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000 − 32.768)
Range
-32.768 to 32.7669
Unit
Number

In testing for 1998 to 2024.

Leakage low-frequency current FORTWO_LEAK_LF

  • Request22 50 68
  • Service 22DID 5068
  • Module792 → 793
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000 − 32.768)
Range
-32.768 to 32.7669
Unit
Number

In testing for 1998 to 2024.

Lowest cell voltage FORTWO_CELL_V_MIN

  • Request21 07
  • Service 21PID 07
  • Module79B → 7BB
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 1998 to 2024.

Mains active power FORTWO_MAINS_P

  • Request22 50 4A
  • Service 22DID 504A
  • Module792 → 793
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000 − 20)
Range
-20 to 45.5349 kW
Unit
kW

In testing for 1998 to 2024.

Mains current limit FORTWO_MAINS_A_LIMIT

  • Request22 50 70
  • Service 22DID 5070
  • Module792 → 793
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000 − 32.768)
Range
-32.768 to 32.7669
Unit
Number

In testing for 1998 to 2024.

Mains current, phase 2 FORTWO_MAINS_A_2

  • Request22 50 3A
  • Service 22DID 503A
  • Module792 → 793
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 16 − 200)
Range
-200 to 3895.9375 A
Unit
A

In testing for 1998 to 2024.

Mains current, phase 3 FORTWO_MAINS_A_3

  • Request22 50 3B
  • Service 22DID 503B
  • Module792 → 793
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 16 − 200)
Range
-200 to 3895.9375 A
Unit
A

In testing for 1998 to 2024.

Mains frequency FORTWO_MAINS_HZ

  • Request22 50 49
  • Service 22DID 5049
  • Module792 → 793
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 128 + 10)
Range
10 to 521.9921 Hz
Unit
Hz

In testing for 1998 to 2024.

Mains ground resistance FORTWO_MAINS_GND_R

  • Request22 50 62
  • Service 22DID 5062
  • Module792 → 793
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000 − 32.768)
Range
-32.768 to 32.7669
Unit
Number

In testing for 1998 to 2024.

Mains voltage, phases 1-2 FORTWO_MAINS_V_12

  • Request22 50 3F
  • Service 22DID 503F
  • Module792 → 793
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 2)
Range
0 to 32767.5 V
Unit
V

In testing for 1998 to 2024.

Mains voltage, phases 2-3 FORTWO_MAINS_V_23

  • Request22 50 41
  • Service 22DID 5041
  • Module792 → 793
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 2)
Range
0 to 32767.5 V
Unit
V

In testing for 1998 to 2024.

Mains voltage, phases 3-1 FORTWO_MAINS_V_31

  • Request22 50 42
  • Service 22DID 5042
  • Module792 → 793
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 2)
Range
0 to 32767.5 V
Unit
V

In testing for 1998 to 2024.

Open-circuit voltage state FORTWO_OCV_STATE

  • Request21 08
  • Service 21PID 08
  • Module79B → 7BB
  • Every10 s
  • Testing

Bits 112 to 119 of the reply, 8 bits.

Formula
val
Range
0 to 4
Unit
Number

In testing for 1998 to 2024.

Real state of charge, maximum FORTWO_SOC_REAL_MAX

  • Request21 08
  • Service 21PID 08
  • Module79B → 7BB
  • Every10 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
(val ÷ 16)
Range
0 to 4095.9375 %
Unit
%

In testing for 1998 to 2024.

Real state of charge, minimum FORTWO_SOC_REAL_MIN

  • Request21 08
  • Service 21PID 08
  • Module79B → 7BB
  • Every10 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
(val ÷ 16)
Range
0 to 4095.9375 %
Unit
%

In testing for 1998 to 2024.

Service interlock closed FORTWO_HV_INTERLOCK_SVC

  • Request21 07
  • Service 21PID 07
  • Module79B → 7BB
  • Every5 s
  • Testing

Bits 112 to 119 of the reply, 8 bits.

Formula
val
Range
0 to 1
Unit
Yes or no

In testing for 1998 to 2024.

State of charge FORTWO_SOC

Pelican can show this parameter as the state of charge.

  • Request21 08
  • Service 21PID 08
  • Module79B → 7BB
  • Every10 s
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
(val ÷ 16)
Range
0 to 4095.9375 %
Unit
%

In testing for 1998 to 2024.

State of charge recalibration state FORTWO_SOC_RECAL

  • Request21 25
  • Service 21PID 25
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 3
Unit
Number

In testing for 1998 to 2024.

State of charge, displayed FORTWO_SOC_DISPLAY

  • Request21 25
  • Service 21PID 25
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 8 to 23 of the reply, 16 bits.

Formula
(val ÷ 16)
Range
0 to 4095.9375 %
Unit
%

In testing for 1998 to 2024.

State of health FORTWO_SOH

Pelican can show this parameter as the state of health.

  • Request21 61
  • Service 21PID 61
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 64 to 71 of the reply, 8 bits.

Formula
(val ÷ 2)
Range
0 to 127.5 %
Unit
%

In testing for 1998 to 2024.

State of health, raw FORTWO_ED_SOH

  • Request22 03 10
  • Service 22DID 0310
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 80 to 87 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1998 to 2024.

Sum of cell voltages FORTWO_HV_CELL_SUM_V

  • Request21 07
  • Service 21PID 07
  • Module79B → 7BB
  • Every5 s
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
(val ÷ 64)
Range
0 to 1023.9843 V
Unit
V

In testing for 1998 to 2024.

Time with HV off FORTWO_ED_HV_OFF_TIME

  • Request22 03 10
  • Service 22DID 0310
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 8 to 31 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 s
Unit
s

In testing for 1998 to 2024.

Usable capacity, full FORTWO_CAP_FULL

  • Request21 61
  • Service 21PID 61
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 48 to 63 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 360)
Range
-91.0222 to 91.0194 Ah
Unit
Ah

In testing for 1998 to 2024.

Battery › Cells

Cell 1 voltage FORTWO_CELL_V1

  • Request21 41
  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 1998 to 2024.

Cell 1 voltage FORTWO_ED_CELL_V1

  • Request22 02 08
  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 1998 to 2024.

Cell 2 voltage FORTWO_CELL_V2

  • Request21 41
  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 1998 to 2024.

Cell 2 voltage FORTWO_ED_CELL_V2

  • Request22 02 08
  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 1998 to 2024.

Cell 3 voltage FORTWO_CELL_V3

  • Request21 41
  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 1998 to 2024.

Cell 3 voltage FORTWO_ED_CELL_V3

  • Request22 02 08
  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 1998 to 2024.

Cell 4 voltage FORTWO_CELL_V4

  • Request21 41
  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 1998 to 2024.

Cell 4 voltage FORTWO_ED_CELL_V4

  • Request22 02 08
  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 1998 to 2024.

Cell 5 voltage FORTWO_CELL_V5

  • Request21 41
  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 1998 to 2024.

Cell 5 voltage FORTWO_ED_CELL_V5

  • Request22 02 08
  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 1998 to 2024.

Cell 6 voltage FORTWO_CELL_V6

  • Request21 41
  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 80 to 95 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 1998 to 2024.

Cell 6 voltage FORTWO_ED_CELL_V6

  • Request22 02 08
  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 80 to 95 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 1998 to 2024.

Cell 7 voltage FORTWO_CELL_V7

  • Request21 41
  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 96 to 111 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 1998 to 2024.

Cell 7 voltage FORTWO_ED_CELL_V7

  • Request22 02 08
  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 96 to 111 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 1998 to 2024.

Cell 8 voltage FORTWO_CELL_V8

  • Request21 41
  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 112 to 127 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 1998 to 2024.

Cell 8 voltage FORTWO_ED_CELL_V8

  • Request22 02 08
  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 112 to 127 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 1998 to 2024.

Cell 9 voltage FORTWO_CELL_V9

  • Request21 41
  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 128 to 143 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 1998 to 2024.

Cell 9 voltage FORTWO_ED_CELL_V9

  • Request22 02 08
  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 128 to 143 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 1998 to 2024.

Cell 10 voltage FORTWO_CELL_V10

  • Request21 41
  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 144 to 159 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 1998 to 2024.

Cell 10 voltage FORTWO_ED_CELL_V10

  • Request22 02 08
  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 144 to 159 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 1998 to 2024.

Cell 11 voltage FORTWO_CELL_V11

  • Request21 41
  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 160 to 175 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 1998 to 2024.

Cell 11 voltage FORTWO_ED_CELL_V11

  • Request22 02 08
  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 160 to 175 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 1998 to 2024.

Cell 12 voltage FORTWO_CELL_V12

  • Request21 41
  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 176 to 191 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 1998 to 2024.

Cell 12 voltage FORTWO_ED_CELL_V12

  • Request22 02 08
  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 176 to 191 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 1998 to 2024.

Cell 13 voltage FORTWO_CELL_V13

  • Request21 41
  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 192 to 207 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 1998 to 2024.

Cell 13 voltage FORTWO_ED_CELL_V13

  • Request22 02 08
  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 192 to 207 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 1998 to 2024.

Cell 14 voltage FORTWO_CELL_V14

  • Request21 41
  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 208 to 223 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 1998 to 2024.

Cell 14 voltage FORTWO_ED_CELL_V14

  • Request22 02 08
  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 208 to 223 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 1998 to 2024.

Cell 15 voltage FORTWO_CELL_V15

  • Request21 41
  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 224 to 239 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 1998 to 2024.

Cell 15 voltage FORTWO_ED_CELL_V15

  • Request22 02 08
  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 224 to 239 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 1998 to 2024.

Cell 16 voltage FORTWO_CELL_V16

  • Request21 41
  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 240 to 255 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 1998 to 2024.

Cell 16 voltage FORTWO_ED_CELL_V16

  • Request22 02 08
  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 240 to 255 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 1998 to 2024.

Cell 17 voltage FORTWO_CELL_V17

  • Request21 41
  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 256 to 271 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 1998 to 2024.

Cell 17 voltage FORTWO_ED_CELL_V17

  • Request22 02 08
  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 256 to 271 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 1998 to 2024.

Cell 18 voltage FORTWO_CELL_V18

  • Request21 41
  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 272 to 287 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 1998 to 2024.

Cell 18 voltage FORTWO_ED_CELL_V18

  • Request22 02 08
  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 272 to 287 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 1998 to 2024.

Cell 19 voltage FORTWO_CELL_V19

  • Request21 41
  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 288 to 303 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 1998 to 2024.

Cell 19 voltage FORTWO_ED_CELL_V19

  • Request22 02 08
  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 288 to 303 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 1998 to 2024.

Cell 20 voltage FORTWO_CELL_V20

  • Request21 41
  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 304 to 319 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 1998 to 2024.

Cell 20 voltage FORTWO_ED_CELL_V20

  • Request22 02 08
  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 304 to 319 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 1998 to 2024.

Cell 21 voltage FORTWO_CELL_V21

  • Request21 41
  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 320 to 335 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 1998 to 2024.

Cell 21 voltage FORTWO_ED_CELL_V21

  • Request22 02 08
  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 320 to 335 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 1998 to 2024.

Cell 22 voltage FORTWO_CELL_V22

  • Request21 41
  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 336 to 351 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 1998 to 2024.

Cell 22 voltage FORTWO_ED_CELL_V22

  • Request22 02 08
  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 336 to 351 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 1998 to 2024.

Cell 23 voltage FORTWO_CELL_V23

  • Request21 41
  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 352 to 367 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 1998 to 2024.

Cell 23 voltage FORTWO_ED_CELL_V23

  • Request22 02 08
  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 352 to 367 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 1998 to 2024.

Cell 24 voltage FORTWO_CELL_V24

  • Request21 41
  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 368 to 383 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 1998 to 2024.

Cell 24 voltage FORTWO_ED_CELL_V24

  • Request22 02 08
  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 368 to 383 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 1998 to 2024.

Cell 25 voltage FORTWO_CELL_V25

  • Request21 41
  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 384 to 399 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 1998 to 2024.

Cell 25 voltage FORTWO_ED_CELL_V25

  • Request22 02 08
  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 384 to 399 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 1998 to 2024.

Cell 26 voltage FORTWO_CELL_V26

  • Request21 41
  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 400 to 415 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 1998 to 2024.

Cell 26 voltage FORTWO_ED_CELL_V26

  • Request22 02 08
  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 400 to 415 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 1998 to 2024.

Cell 27 voltage FORTWO_CELL_V27

  • Request21 41
  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 416 to 431 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 1998 to 2024.

Cell 27 voltage FORTWO_ED_CELL_V27

  • Request22 02 08
  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 416 to 431 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 1998 to 2024.

Cell 28 voltage FORTWO_CELL_V28

  • Request21 41
  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 432 to 447 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 1998 to 2024.

Cell 28 voltage FORTWO_ED_CELL_V28

  • Request22 02 08
  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 432 to 447 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 1998 to 2024.

Cell 29 voltage FORTWO_CELL_V29

  • Request21 41
  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 448 to 463 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 1998 to 2024.

Cell 29 voltage FORTWO_ED_CELL_V29

  • Request22 02 08
  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 448 to 463 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 1998 to 2024.

Cell 30 voltage FORTWO_CELL_V30

  • Request21 41
  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 464 to 479 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 1998 to 2024.

Cell 30 voltage FORTWO_ED_CELL_V30

  • Request22 02 08
  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 464 to 479 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 1998 to 2024.

Cell 31 voltage FORTWO_CELL_V31

  • Request21 41
  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 480 to 495 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 1998 to 2024.

Cell 31 voltage FORTWO_ED_CELL_V31

  • Request22 02 08
  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 480 to 495 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 1998 to 2024.

Cell 32 voltage FORTWO_CELL_V32

  • Request21 41
  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 496 to 511 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 1998 to 2024.

Cell 32 voltage FORTWO_ED_CELL_V32

  • Request22 02 08
  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 496 to 511 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 1998 to 2024.

Cell 33 voltage FORTWO_CELL_V33

  • Request21 41
  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 512 to 527 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 1998 to 2024.

Cell 33 voltage FORTWO_ED_CELL_V33

  • Request22 02 08
  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 512 to 527 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 1998 to 2024.

Cell 34 voltage FORTWO_CELL_V34

  • Request21 41
  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 528 to 543 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 1998 to 2024.

Cell 34 voltage FORTWO_ED_CELL_V34

  • Request22 02 08
  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 528 to 543 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 1998 to 2024.

Cell 35 voltage FORTWO_CELL_V35

  • Request21 41
  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 544 to 559 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 1998 to 2024.

Cell 35 voltage FORTWO_ED_CELL_V35

  • Request22 02 08
  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 544 to 559 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 1998 to 2024.

Cell 36 voltage FORTWO_CELL_V36

  • Request21 41
  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 560 to 575 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 1998 to 2024.

Cell 36 voltage FORTWO_ED_CELL_V36

  • Request22 02 08
  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 560 to 575 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 1998 to 2024.

Cell 37 voltage FORTWO_CELL_V37

  • Request21 41
  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 576 to 591 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 1998 to 2024.

Cell 37 voltage FORTWO_ED_CELL_V37

  • Request22 02 08
  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 576 to 591 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 1998 to 2024.

Cell 38 voltage FORTWO_CELL_V38

  • Request21 41
  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 592 to 607 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 1998 to 2024.

Cell 38 voltage FORTWO_ED_CELL_V38

  • Request22 02 08
  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 592 to 607 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 1998 to 2024.

Cell 39 voltage FORTWO_CELL_V39

  • Request21 41
  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 608 to 623 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 1998 to 2024.

Cell 39 voltage FORTWO_ED_CELL_V39

  • Request22 02 08
  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 608 to 623 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 1998 to 2024.

Cell 40 voltage FORTWO_CELL_V40

  • Request21 41
  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 624 to 639 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 1998 to 2024.

Cell 40 voltage FORTWO_ED_CELL_V40

  • Request22 02 08
  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 624 to 639 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 1998 to 2024.

Cell 41 voltage FORTWO_CELL_V41

  • Request21 41
  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 640 to 655 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 1998 to 2024.

Cell 41 voltage FORTWO_ED_CELL_V41

  • Request22 02 08
  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 640 to 655 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 1998 to 2024.

Cell 42 voltage FORTWO_CELL_V42

  • Request21 41
  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 656 to 671 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 1998 to 2024.

Cell 42 voltage FORTWO_ED_CELL_V42

  • Request22 02 08
  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 656 to 671 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 1998 to 2024.

Cell 43 voltage FORTWO_CELL_V43

  • Request21 41
  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 672 to 687 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 1998 to 2024.

Cell 43 voltage FORTWO_ED_CELL_V43

  • Request22 02 08
  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 672 to 687 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 1998 to 2024.

Cell 44 voltage FORTWO_CELL_V44

  • Request21 41
  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 688 to 703 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 1998 to 2024.

Cell 44 voltage FORTWO_ED_CELL_V44

  • Request22 02 08
  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 688 to 703 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 1998 to 2024.

Cell 45 voltage FORTWO_CELL_V45

  • Request21 41
  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 704 to 719 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 1998 to 2024.

Cell 45 voltage FORTWO_ED_CELL_V45

  • Request22 02 08
  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 704 to 719 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 1998 to 2024.

Cell 46 voltage FORTWO_CELL_V46

  • Request21 41
  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 720 to 735 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 1998 to 2024.

Cell 46 voltage FORTWO_ED_CELL_V46

  • Request22 02 08
  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 720 to 735 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 1998 to 2024.

Cell 47 voltage FORTWO_CELL_V47

  • Request21 41
  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 736 to 751 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 1998 to 2024.

Cell 47 voltage FORTWO_ED_CELL_V47

  • Request22 02 08
  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 736 to 751 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 1998 to 2024.

Cell 48 voltage FORTWO_CELL_V48

  • Request21 41
  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 752 to 767 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 1998 to 2024.

Cell 48 voltage FORTWO_ED_CELL_V48

  • Request22 02 08
  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 752 to 767 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 1998 to 2024.

Cell 49 voltage FORTWO_CELL_V49

  • Request21 42
  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 1998 to 2024.

Cell 49 voltage FORTWO_ED_CELL_V49

  • Request22 02 08
  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 768 to 783 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 1998 to 2024.

Cell 50 voltage FORTWO_CELL_V50

  • Request21 42
  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 1998 to 2024.

Cell 50 voltage FORTWO_ED_CELL_V50

  • Request22 02 08
  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 784 to 799 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 1998 to 2024.

Cell 51 voltage FORTWO_CELL_V51

  • Request21 42
  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 1998 to 2024.

Cell 51 voltage FORTWO_ED_CELL_V51

  • Request22 02 08
  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 800 to 815 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 1998 to 2024.

Cell 52 voltage FORTWO_CELL_V52

  • Request21 42
  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 1998 to 2024.

Cell 52 voltage FORTWO_ED_CELL_V52

  • Request22 02 08
  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 816 to 831 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 1998 to 2024.

Cell 53 voltage FORTWO_CELL_V53

  • Request21 42
  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 1998 to 2024.

Cell 53 voltage FORTWO_ED_CELL_V53

  • Request22 02 08
  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 832 to 847 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 1998 to 2024.

Cell 54 voltage FORTWO_CELL_V54

  • Request21 42
  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 80 to 95 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 1998 to 2024.

Cell 54 voltage FORTWO_ED_CELL_V54

  • Request22 02 08
  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 848 to 863 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 1998 to 2024.

Cell 55 voltage FORTWO_CELL_V55

  • Request21 42
  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 96 to 111 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 1998 to 2024.

Cell 55 voltage FORTWO_ED_CELL_V55

  • Request22 02 08
  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 864 to 879 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 1998 to 2024.

Cell 56 voltage FORTWO_CELL_V56

  • Request21 42
  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 112 to 127 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 1998 to 2024.

Cell 56 voltage FORTWO_ED_CELL_V56

  • Request22 02 08
  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 880 to 895 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 1998 to 2024.

Cell 57 voltage FORTWO_CELL_V57

  • Request21 42
  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 128 to 143 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 1998 to 2024.

Cell 57 voltage FORTWO_ED_CELL_V57

  • Request22 02 08
  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 896 to 911 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 1998 to 2024.

Cell 58 voltage FORTWO_CELL_V58

  • Request21 42
  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 144 to 159 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 1998 to 2024.

Cell 58 voltage FORTWO_ED_CELL_V58

  • Request22 02 08
  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 912 to 927 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 1998 to 2024.

Cell 59 voltage FORTWO_CELL_V59

  • Request21 42
  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 160 to 175 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 1998 to 2024.

Cell 59 voltage FORTWO_ED_CELL_V59

  • Request22 02 08
  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 928 to 943 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 1998 to 2024.

Cell 60 voltage FORTWO_CELL_V60

  • Request21 42
  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 176 to 191 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 1998 to 2024.

Cell 60 voltage FORTWO_ED_CELL_V60

  • Request22 02 08
  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 944 to 959 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 1998 to 2024.

Cell 61 voltage FORTWO_CELL_V61

  • Request21 42
  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 192 to 207 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 1998 to 2024.

Cell 61 voltage FORTWO_ED_CELL_V61

  • Request22 02 08
  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 960 to 975 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 1998 to 2024.

Cell 62 voltage FORTWO_CELL_V62

  • Request21 42
  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 208 to 223 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 1998 to 2024.

Cell 62 voltage FORTWO_ED_CELL_V62

  • Request22 02 08
  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 976 to 991 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 1998 to 2024.

Cell 63 voltage FORTWO_CELL_V63

  • Request21 42
  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 224 to 239 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 1998 to 2024.

Cell 63 voltage FORTWO_ED_CELL_V63

  • Request22 02 08
  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 992 to 1,007 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 1998 to 2024.

Cell 64 voltage FORTWO_CELL_V64

  • Request21 42
  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 240 to 255 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 1998 to 2024.

Cell 64 voltage FORTWO_ED_CELL_V64

  • Request22 02 08
  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 1,008 to 1,023 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 1998 to 2024.

Cell 65 voltage FORTWO_CELL_V65

  • Request21 42
  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 256 to 271 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 1998 to 2024.

Cell 65 voltage FORTWO_ED_CELL_V65

  • Request22 02 08
  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 1,024 to 1,039 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 1998 to 2024.

Cell 66 voltage FORTWO_CELL_V66

  • Request21 42
  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 272 to 287 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 1998 to 2024.

Cell 66 voltage FORTWO_ED_CELL_V66

  • Request22 02 08
  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 1,040 to 1,055 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 1998 to 2024.

Cell 67 voltage FORTWO_CELL_V67

  • Request21 42
  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 288 to 303 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 1998 to 2024.

Cell 67 voltage FORTWO_ED_CELL_V67

  • Request22 02 08
  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 1,056 to 1,071 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 1998 to 2024.

Cell 68 voltage FORTWO_CELL_V68

  • Request21 42
  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 304 to 319 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 1998 to 2024.

Cell 68 voltage FORTWO_ED_CELL_V68

  • Request22 02 08
  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 1,072 to 1,087 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 1998 to 2024.

Cell 69 voltage FORTWO_CELL_V69

  • Request21 42
  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 320 to 335 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 1998 to 2024.

Cell 69 voltage FORTWO_ED_CELL_V69

  • Request22 02 08
  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 1,088 to 1,103 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 1998 to 2024.

Cell 70 voltage FORTWO_CELL_V70

  • Request21 42
  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 336 to 351 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 1998 to 2024.

Cell 70 voltage FORTWO_ED_CELL_V70

  • Request22 02 08
  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 1,104 to 1,119 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 1998 to 2024.

Cell 71 voltage FORTWO_CELL_V71

  • Request21 42
  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 352 to 367 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 1998 to 2024.

Cell 71 voltage FORTWO_ED_CELL_V71

  • Request22 02 08
  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 1,120 to 1,135 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 1998 to 2024.

Cell 72 voltage FORTWO_CELL_V72

  • Request21 42
  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 368 to 383 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 1998 to 2024.

Cell 72 voltage FORTWO_ED_CELL_V72

  • Request22 02 08
  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 1,136 to 1,151 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 1998 to 2024.

Cell 73 voltage FORTWO_CELL_V73

  • Request21 42
  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 384 to 399 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 1998 to 2024.

Cell 73 voltage FORTWO_ED_CELL_V73

  • Request22 02 08
  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 1,152 to 1,167 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 1998 to 2024.

Cell 74 voltage FORTWO_CELL_V74

  • Request21 42
  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 400 to 415 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 1998 to 2024.

Cell 74 voltage FORTWO_ED_CELL_V74

  • Request22 02 08
  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 1,168 to 1,183 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 1998 to 2024.

Cell 75 voltage FORTWO_CELL_V75

  • Request21 42
  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 416 to 431 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 1998 to 2024.

Cell 75 voltage FORTWO_ED_CELL_V75

  • Request22 02 08
  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 1,184 to 1,199 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 1998 to 2024.

Cell 76 voltage FORTWO_CELL_V76

  • Request21 42
  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 432 to 447 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 1998 to 2024.

Cell 76 voltage FORTWO_ED_CELL_V76

  • Request22 02 08
  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 1,200 to 1,215 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 1998 to 2024.

Cell 77 voltage FORTWO_CELL_V77

  • Request21 42
  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 448 to 463 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 1998 to 2024.

Cell 77 voltage FORTWO_ED_CELL_V77

  • Request22 02 08
  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 1,216 to 1,231 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 1998 to 2024.

Cell 78 voltage FORTWO_CELL_V78

  • Request21 42
  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 464 to 479 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 1998 to 2024.

Cell 78 voltage FORTWO_ED_CELL_V78

  • Request22 02 08
  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 1,232 to 1,247 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 1998 to 2024.

Cell 79 voltage FORTWO_CELL_V79

  • Request21 42
  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 480 to 495 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 1998 to 2024.

Cell 79 voltage FORTWO_ED_CELL_V79

  • Request22 02 08
  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 1,248 to 1,263 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 1998 to 2024.

Cell 80 voltage FORTWO_CELL_V80

  • Request21 42
  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 496 to 511 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 1998 to 2024.

Cell 80 voltage FORTWO_ED_CELL_V80

  • Request22 02 08
  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 1,264 to 1,279 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 1998 to 2024.

Cell 81 voltage FORTWO_CELL_V81

  • Request21 42
  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 512 to 527 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 1998 to 2024.

Cell 81 voltage FORTWO_ED_CELL_V81

  • Request22 02 08
  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 1,280 to 1,295 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 1998 to 2024.

Cell 82 voltage FORTWO_CELL_V82

  • Request21 42
  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 528 to 543 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 1998 to 2024.

Cell 82 voltage FORTWO_ED_CELL_V82

  • Request22 02 08
  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 1,296 to 1,311 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 1998 to 2024.

Cell 83 voltage FORTWO_CELL_V83

  • Request21 42
  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 544 to 559 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 1998 to 2024.

Cell 83 voltage FORTWO_ED_CELL_V83

  • Request22 02 08
  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 1,312 to 1,327 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 1998 to 2024.

Cell 84 voltage FORTWO_CELL_V84

  • Request21 42
  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 560 to 575 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 1998 to 2024.

Cell 84 voltage FORTWO_ED_CELL_V84

  • Request22 02 08
  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 1,328 to 1,343 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 1998 to 2024.

Cell 85 voltage FORTWO_CELL_V85

  • Request21 42
  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 576 to 591 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 1998 to 2024.

Cell 85 voltage FORTWO_ED_CELL_V85

  • Request22 02 08
  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 1,344 to 1,359 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 1998 to 2024.

Cell 86 voltage FORTWO_CELL_V86

  • Request21 42
  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 592 to 607 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 1998 to 2024.

Cell 86 voltage FORTWO_ED_CELL_V86

  • Request22 02 08
  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 1,360 to 1,375 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 1998 to 2024.

Cell 87 voltage FORTWO_CELL_V87

  • Request21 42
  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 608 to 623 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 1998 to 2024.

Cell 87 voltage FORTWO_ED_CELL_V87

  • Request22 02 08
  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 1,376 to 1,391 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 1998 to 2024.

Cell 88 voltage FORTWO_CELL_V88

  • Request21 42
  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 624 to 639 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 1998 to 2024.

Cell 88 voltage FORTWO_ED_CELL_V88

  • Request22 02 08
  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 1,392 to 1,407 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 1998 to 2024.

Cell 89 voltage FORTWO_CELL_V89

  • Request21 42
  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 640 to 655 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 1998 to 2024.

Cell 89 voltage FORTWO_ED_CELL_V89

  • Request22 02 08
  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 1,408 to 1,423 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 1998 to 2024.

Cell 90 voltage FORTWO_CELL_V90

  • Request21 42
  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 656 to 671 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 1998 to 2024.

Cell 90 voltage FORTWO_ED_CELL_V90

  • Request22 02 08
  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 1,424 to 1,439 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 1998 to 2024.

Cell 91 voltage FORTWO_CELL_V91

  • Request21 42
  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 672 to 687 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 1998 to 2024.

Cell 91 voltage FORTWO_ED_CELL_V91

  • Request22 02 08
  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 1,440 to 1,455 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 1998 to 2024.

Cell 92 voltage FORTWO_CELL_V92

  • Request21 42
  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 688 to 703 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 1998 to 2024.

Cell 92 voltage FORTWO_ED_CELL_V92

  • Request22 02 08
  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 1,456 to 1,471 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 1998 to 2024.

Cell 93 voltage FORTWO_CELL_V93

  • Request21 42
  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 704 to 719 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 1998 to 2024.

Cell 93 voltage FORTWO_ED_CELL_V93

  • Request22 02 08
  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 1,472 to 1,487 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 1998 to 2024.

Cell 94 voltage FORTWO_CELL_V94

  • Request21 42
  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 720 to 735 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 1998 to 2024.

Cell 95 voltage FORTWO_CELL_V95

  • Request21 42
  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 736 to 751 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 1998 to 2024.

Cell 96 voltage FORTWO_CELL_V96

  • Request21 42
  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 752 to 767 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 1998 to 2024.

Keyboard shortcuts

jk/↓↑
Move down or up through a list or a grid.
hl/←→
Move across a row or between cards.
Enter
Open the focused link.
f
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.