Engine parameters
The Peugeot 308 has 168 engine parameters.
● Confirmed◆ In testing○ Supported× Not supported
5V power supply state number 1 308_5V_POWER_SUP_ST_1
- Request
22 D4 23 - Service 22
DID D423 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2007 to 2018, 2020 to 2026. Not supported for 2019.
5V power supply state number 2 308_5V_POWER_SUP_ST_2
- Request
22 D4 24 - Service 22
DID D424 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2007 to 2018, 2020 to 2026. Not supported for 2019.
5V power supply state number 3 308_5V_POWER_SUP_ST_3
- Request
22 D4 25 - Service 22
DID D425 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2007 to 2018, 2020 to 2026. Not supported for 2019.
5V power supply state number 4 308_5V_POWER_SUP_ST_4
- Request
22 D4 26 - Service 22
DID D426 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2007 to 2018, 2020 to 2026. Not supported for 2019.
12V network allowed stop 308_12V_NETWORK_ALLOWEDConfirmed
- Request
22 D7 4C - Service 22
DID D74C - Module
6A8 → 688 - Every
1 s - Testing for 2007 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 308.
Bits 0 to 7 of the reply, 8 bits.
0x00 = 0 → 0
- Formula
val- Range
- 0 to 255
- Unit
- Number
Confirmed for 2019. In testing for 2007 to 2018, 2020 to 2026.
Activation count, brake electromagnetic valve B1 308_NUM_ACTIVATIONS_B1Confirmed
- Request
22 D7 45 - Service 22
DID D745 - Module
6A9 → 689 - Every
250 ms - Testing for 2007 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 308.
Bits 0 to 31 of the reply, 32 bits.
0x00030292 = 197266 → 197,266
- Formula
val- Range
- 0 to 4294967295
- Unit
- Number
Confirmed for 2019. In testing for 2007 to 2018, 2020 to 2026.
Activation count, line pressure control solenoid 308_NUM_LINE_P_CTRLConfirmed
- Request
22 D7 51 - Service 22
DID D751 - Module
6A9 → 689 - Every
1 s - Testing for 2007 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 308.
Bits 0 to 31 of the reply, 32 bits.
0x00004B04 = 19204 → 19,204
- Formula
val- Range
- 0 to 4294967295
- Unit
- Number
Confirmed for 2019. In testing for 2007 to 2018, 2020 to 2026.
Activation count, the electromagnetic valve of brake B2 308_NUM_ACTIVATIONS_B2Confirmed
- Request
22 D7 5A - Service 22
DID D75A - Module
6A9 → 689 - Every
250 ms - Testing for 2007 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 308.
Bits 0 to 31 of the reply, 32 bits.
0x0000A590 = 42384 → 42,384
- Formula
val- Range
- 0 to 4294967295
- Unit
- Number
Confirmed for 2019. In testing for 2007 to 2018, 2020 to 2026.
Actual oil pressure 308_ACT_OIL_P
- Request
21 C5 - Service 21
PID C5 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 144 to 151 of the reply, 8 bits.
- Formula
(val ÷ 20)- Range
- 0 to 12.75 bar
- Unit
- bar
In testing for 2007 to 2018, 2020 to 2026. Not supported for 2019.
Additional heater control 1 308_ADDITIONAL_HEATER_1
- Request
22 D4 16 - Service 22
DID D416 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2007 to 2018, 2020 to 2026. Not supported for 2019.
Air conditioning 308_ACConfirmed
- Request
22 D4 AF - Service 22
DID D4AF - Module
6A8 → 688 - Every
1 s - Testing for 2007 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 308.
Bits 0 to 7 of the reply, 8 bits.
0x01 = 1 → 1
- Formula
val- Range
- 0 to 255
- Unit
- Number
Confirmed for 2019. In testing for 2007 to 2018, 2020 to 2026.
Air conditioning compressor current 308_AC_COMP_CURRENTConfirmed
- Request
22 D4 1C - Service 22
DID D41C - Module
6A8 → 688 - Every
1 s - Testing for 2007 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 308.
Bits 0 to 7 of the reply, 8 bits.
0x06 = 6 → (6 × 25) = 150
- Formula
(val × 25)- Range
- 0 to 6375
- Unit
- Number
Confirmed for 2019. In testing for 2007 to 2018, 2020 to 2026.
Air conditioning pressure 308_AC_PConfirmed
- Request
22 D4 21 - Service 22
DID D421 - Module
6A8 → 688 - Every
1 s - Testing for 2007 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 308.
Bits 0 to 15 of the reply, 16 bits.
0x27F7 = 10231 → (10231 ÷ 1000) = 10.231 bar
- Formula
(val ÷ 1000)- Range
- 0 to 65.53 bar
- Unit
- bar
Confirmed for 2019. In testing for 2007 to 2018, 2020 to 2026.
Air flow 308_AIR_FLOW
- Request
22 D4 89 - Service 22
DID D489 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276 to 3276
- Unit
- Raw value
In testing for 2007 to 2018, 2020 to 2026. Not supported for 2019.
Air flow target 308_AIR_FLOW_TGT
- Request
22 D4 8E - Service 22
DID D48E - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276 to 3276
- Unit
- Raw value
In testing for 2007 to 2018, 2020 to 2026. Not supported for 2019.
Air temperature by air flow meter 308_AIR_T_AIR_FLOW_METER
- Request
22 D5 4E - Service 22
DID D54E - Module
6A8 → 688 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10 − 273.1400146)- Range
- -3549 to 3003 °C
- Unit
- °C
In testing for 2007 to 2018, 2020 to 2026. Not supported for 2019.
Alternator load value 308_ALTERNATOR_LOADConfirmed
- Request
22 D4 A5 - Service 22
DID D4A5 - Module
6A8 → 688 - Every
1 s - Testing for 2007 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 308.
Bits 0 to 7 of the reply, 8 bits.
0x0D = 13 → 13 %
- Formula
val- Range
- 0 to 255 %
- Unit
- %
Confirmed for 2019. In testing for 2007 to 2018, 2020 to 2026.
Ambient air temperature 308_AAT_6A9Confirmed
- Request
22 D5 52 - Service 22
DID D552 - Module
6A9 → 689 - Every
5 s - Testing for 2007 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 308.
Bits 0 to 7 of the reply, 8 bits.
0x6D = 109 → (109 ÷ 2 − 40) = 14.5 °C
- Formula
(val ÷ 2 − 40)- Range
- -40 to 87.5 °C
- Unit
- °C
Confirmed for 2019. In testing for 2007 to 2018, 2020 to 2026.
ANTI START PROGRAMMING STATUS 308_ANTI_STARTConfirmed
- Request
22 DA DC - Service 22
DID DADC - Module
6A9 → 689 - Every
1 s - Testing for 2007 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 308.
Bits 8 to 15 of the reply, 8 bits.
0x04 = 4 → 4
- Formula
val- Range
- 0 to 255
- Unit
- Number
Confirmed for 2019. In testing for 2007 to 2018, 2020 to 2026.
Atmospheric pressure 308_ATMOSPHERIC_PConfirmed
- Request
22 D4 65 - Service 22
DID D465 - Module
6A8 → 688 - Every
1 s - Testing for 2007 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 308.
Bits 0 to 15 of the reply, 16 bits.
0x3198 = 12696 → 12,696
- Formula
val- Range
- 0 to 65535
- Unit
- Raw value
Confirmed for 2019. In testing for 2007 to 2018, 2020 to 2026.
Automatic restart request from body control module 308_AUTOMATIC_RESTART_REQ_BSIConfirmed
- Request
22 D7 0A - Service 22
DID D70A - Module
6A8 → 688 - Every
1 s - Testing for 2007 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 308.
Bits 0 to 7 of the reply, 8 bits.
0x00 = 0 → 0
- Formula
val- Range
- 0 to 255
- Unit
- Number
Confirmed for 2019. In testing for 2007 to 2018, 2020 to 2026.
Automatic restart request from engine management computer 308_AUTOMATIC_RESTARTConfirmed
- Request
22 D7 09 - Service 22
DID D709 - Module
6A8 → 688 - Every
1 s - Testing for 2007 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 308.
Bits 0 to 7 of the reply, 8 bits.
0x00 = 0 → 0
- Formula
val- Range
- 0 to 255
- Unit
- Number
Confirmed for 2019. In testing for 2007 to 2018, 2020 to 2026.
Automatic stop allowed by body control module 308_AUTOMATIC_STOPConfirmed
- Request
22 D7 03 - Service 22
DID D703 - Module
6A8 → 688 - Every
1 s - Testing for 2007 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 308.
Bits 0 to 7 of the reply, 8 bits.
0x01 = 1 → 1
- Formula
val- Range
- 0 to 255
- Unit
- Number
Confirmed for 2019. In testing for 2007 to 2018, 2020 to 2026.
Automatic stop allowed by power steering computer 308_AUTOMATIC_STOP_ALLOWED_POWER_STEERConfirmed
- Request
22 D7 05 - Service 22
DID D705 - Module
6A8 → 688 - Every
250 ms - Testing for 2007 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 308.
Bits 0 to 7 of the reply, 8 bits.
0x00 = 0 → 0
- Formula
val- Range
- 0 to 255
- Unit
- Number
Confirmed for 2019. In testing for 2007 to 2018, 2020 to 2026.
Auxiliary heater 2 control 308_AUXILIARY_HEATER_2
- Request
22 D4 17 - Service 22
DID D417 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2007 to 2018, 2020 to 2026. Not supported for 2019.
Barometric pressure BAROSAE J1979Confirmed
Normally obtained from one of a dedicated barometric sensor, a MAP sensor at key-on and during certain modes of driving, or inferred from a MAF sensor and other inputs during certain modes of driving. The control module reports BARO from whatever source it is derived from.
- Request
01 33 - Service 01
PID 33 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 kPa
- Unit
- kPa
Confirmed for 2019, 2024. Supported for 2016, 2022 to 2023, 2025.
Boost air temperature 308_BOOST_AIR_T
- Request
22 D4 11 - Service 22
DID D411 - Module
6A8 → 688 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10 − 273.1400146)- Range
- -3549 to 3003 °C
- Unit
- °C
In testing for 2007 to 2018, 2020 to 2026. Not supported for 2019.
Button state 308_BUTTON_STConfirmed
- Request
22 D5 17 - Service 22
DID D517 - Module
6A9 → 689 - Every
1 s - Testing for 2007 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 308.
Bits 0 to 7 of the reply, 8 bits.
0x00 = 0 → 0
- Formula
val- Range
- 0 to 255
- Unit
- Number
Confirmed for 2019. In testing for 2007 to 2018, 2020 to 2026.
Calculated engine load LOAD_PCTSAE J1979Confirmed
Represents the amount of work the engine is doing. Expected to reach 100% at wide open throttle/wide open pedal at any altitude, temperature or rpm for both naturally aspirated and boosted engines. If engine load is limited for powertrain protection e.g. engine/turbocharger protection, this value may not reach 100%. For hybrid vehicles, indicates the torque produced only by the internal combustion engine, not the torque being delivered by the entire powertrain. For electric vehicles, the meaning of this parameter is undefined.
Pelican can show this parameter as the engine load.
- Request
01 04 - Service 01
PID 04 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2018 to 2019, 2024. Supported for 2010, 2016, 2022 to 2023, 2025.
Camshaft/crankshaft position synchronization 308_CAM_CRANK_POS
- Request
22 D4 18 - Service 22
DID D418 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2007 to 2018, 2020 to 2026. Not supported for 2019.
Catalyst temperature bank 1, sensor 1 CATEMP11SAE J1979Confirmed
- Request
01 3C - Service 01
PID 3C - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10 − 40)- Range
- -40 to 6513.5 °C
- Unit
- °C
Confirmed for 2019, 2024. Supported for 2016, 2022 to 2023, 2025.
CHANGE REPORT IN PROGRESS 308_CHANGE_REPORTConfirmed
- Request
22 D5 16 - Service 22
DID D516 - Module
6A9 → 689 - Every
1 s - Testing for 2007 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 308.
Bits 0 to 7 of the reply, 8 bits.
0x00 = 0 → 0
- Formula
val- Range
- 0 to 255
- Unit
- Number
Confirmed for 2019. In testing for 2007 to 2018, 2020 to 2026.
Combustion engine state 308_ICE_STConfirmed
- Request
22 D7 09 - Service 22
DID D709 - Module
6A9 → 689 - Every
1 s - Testing for 2007 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 308.
Bits 0 to 7 of the reply, 8 bits.
0x03 = 3 → 3
- Formula
val- Range
- 0 to 255
- Unit
- Number
Confirmed for 2019. In testing for 2007 to 2018, 2020 to 2026.
Commanded equivalence ratio EQ_RATSAE J1979Confirmed
Fuel systems that utilize conventional oxygen sensor display the inverse of the commanded open loop equivalence ratio (also known as lambda) while the fuel control system is in open loop. Will indicate 1.000 while in closed-loop fuel.
Pelican can show this parameter as the commanded lambda.
- Request
01 44 - Service 01
PID 44 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 2 ÷ 65535)- Range
- 0 to 1.99
- Unit
- Number
Confirmed for 2018 to 2019, 2024. Supported for 2016, 2022 to 2023, 2025.
Commanded evaporative purge EVAP_PCTSAE J1979Confirmed
- Request
01 2E - Service 01
PID 2E - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2019, 2024. Supported for 2016, 2022 to 2023, 2025.
Commanded oil pressure 308_CMD_OIL_P
- Request
21 C5 - Service 21
PID C5 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 128 to 135 of the reply, 8 bits.
- Formula
(val ÷ 10)- Range
- 0 to 25.5 bar
- Unit
- bar
In testing for 2007 to 2018, 2020 to 2026. Not supported for 2019.
Commanded throttle actuator control TAC_PCTSAE J1979Confirmed
- Request
01 4C - Service 01
PID 4C - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2019, 2024. Supported for 2016, 2022 to 2023, 2025.
Commanded wastegate A position WG_A_CMDSAE J1979Confirmed
If an on/off solenoid is used, is 0% when the wastegate is commanded off (allow full boost), 100% when commanded on (dump boost). If a vacuum solenoid is duty cycled, the duty cycle from 0 to 100% is displayed. If a linear or stepper motor valve is used, the fully closed position (full boost) is displayed as 0%, the fully open position (dump boost) is displayed as 100%. Intermediate positions are displayed as a percent of the full-open position. Any other actuation method is normalized to display 0% when the WG is commanded off and 100% when the WG is commanded on.
- Request
01 72 - Service 01
PID 72 - Module
7E0 → 7E8 - Every
250 ms
Bits 8 to 15 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2019.
Commanded wastegate B position WG_B_CMDSAE J1979Confirmed
If an on/off solenoid is used, is 0% when the wastegate is commanded off (allow full boost), 100% when commanded on (dump boost). If a vacuum solenoid is duty cycled, the duty cycle from 0 to 100% is displayed. If a linear or stepper motor valve is used, the fully closed position (full boost) is displayed as 0%, the fully open position (dump boost) is displayed as 100%. Intermediate positions are displayed as a percent of the full-open position. Any other actuation method is normalized to display 0% when the WG is commanded off and 100% when the WG is commanded on.
- Request
01 72 - Service 01
PID 72 - Module
7E0 → 7E8 - Every
250 ms
Bits 24 to 31 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2019.
Computer lock 308_COMPUTER_LOCKConfirmed
- Request
22 DA DD - Service 22
DID DADD - Module
6A9 → 689 - Every
1 s - Testing for 2007 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 308.
Bits 0 to 7 of the reply, 8 bits.
0x00 = 0 → 0
- Formula
val- Range
- 0 to 255
- Unit
- Number
Confirmed for 2019. In testing for 2007 to 2018, 2020 to 2026.
Computer remote wake-up state 308_COMPUTER_WAKE_UP_STConfirmed
- Request
22 D5 15 - Service 22
DID D515 - Module
6A9 → 689 - Every
1 s - Testing for 2007 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 308.
Bits 0 to 7 of the reply, 8 bits.
0x01 = 1 → 1
- Formula
val- Range
- 0 to 255
- Unit
- Number
Confirmed for 2019. In testing for 2007 to 2018, 2020 to 2026.
Computer restarts since memory erase 308_CNT_NUM_REConfirmed
- Request
22 D4 D8 - Service 22
DID D4D8 - Module
6A8 → 688 - Every
3600 s - Testing for 2007 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 308.
Bits 0 to 15 of the reply, 16 bits.
0x09A0 = 2464 → 2,464
- Formula
val- Range
- 0 to 65535
- Unit
- Number
Confirmed for 2019. In testing for 2007 to 2018, 2020 to 2026.
Computer temperature 308_COMPUTER_TConfirmed
- Request
22 D4 35 - Service 22
DID D435 - Module
6A8 → 688 - Every
5 s - Testing for 2007 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 308.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
0x0018 = 24 → 24 °C
- Formula
val- Range
- -32768 to 32767 °C
- Unit
- °C
Confirmed for 2019. In testing for 2007 to 2018, 2020 to 2026.
Control current of electromagnetic valve for changing the pressure in the brake system B2 308_CTRL_CURRENT_P_B2Confirmed
- Request
22 D6 22 - Service 22
DID D622 - Module
6A9 → 689 - Every
250 ms - Testing for 2007 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 308.
Bits 0 to 7 of the reply, 8 bits.
0x0A = 10 → (10 × 10) = 100 mA
- Formula
(val × 10)- Range
- 0 to 2550 mA
- Unit
- mA
Confirmed for 2019. In testing for 2007 to 2018, 2020 to 2026.
Control current of the electromagnetic valve for changing the pressure in the brake system B1 308_CTRL_CURRENT_P_B1Confirmed
- Request
22 D6 08 - Service 22
DID D608 - Module
6A9 → 689 - Every
250 ms - Testing for 2007 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 308.
Bits 0 to 7 of the reply, 8 bits.
0x0A = 10 → (10 × 10) = 100 mA
- Formula
(val × 10)- Range
- 0 to 2550 mA
- Unit
- mA
Confirmed for 2019. In testing for 2007 to 2018, 2020 to 2026.
Coolant temperature 308_ECT_6A8
Pelican can show this parameter as the engine coolant temperature.
- Request
22 D4 15 - Service 22
DID D415 - Module
6A8 → 688 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10 − 273.1400146)- Range
- -3549 to 3003 °C
- Unit
- °C
In testing for 2007 to 2018, 2020 to 2026. Not supported for 2019.
Coolant temperature target 308_ECT_TGTConfirmed
- Request
22 D4 0D - Service 22
DID D40D - Module
6A8 → 688 - Every
5 s - Testing for 2007 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 308.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
0x0067 = 103 → 103 °C
- Formula
val- Range
- -32768 to 32767 °C
- Unit
- °C
Confirmed for 2019. In testing for 2007 to 2018, 2020 to 2026.
Coolant temperature, corrected 308_ECT_CORRECTEDConfirmed
- Request
22 D4 0A - Service 22
DID D40A - Module
6A8 → 688 - Every
5 s - Testing for 2007 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 308.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
0x0034 = 52 → 52 °C
- Formula
val- Range
- -32768 to 32767 °C
- Unit
- °C
Confirmed for 2019. In testing for 2007 to 2018, 2020 to 2026.
Cruise control, RW status 308_CRUISE_CTRL_RW_STATConfirmed
- Request
22 D4 B0 - Service 22
DID D4B0 - Module
6A8 → 688 - Every
1 s - Testing for 2007 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 308.
Bits 0 to 7 of the reply, 8 bits.
0x00 = 0 → 0
- Formula
val- Range
- 0 to 255
- Unit
- Number
Confirmed for 2019. In testing for 2007 to 2018, 2020 to 2026.
Date 308_DATEConfirmed
- Request
22 D4 CA - Service 22
DID D4CA - Module
6A8 → 688 - Every
1 s - Testing for 2007 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 308.
Bits 0 to 31 of the reply, 32 bits.
0x1F73296E = 527640942 → (527640942 ÷ 10) = 52,764,094.2 s
- Formula
(val ÷ 10)- Range
- 0 to 429496729 s
- Unit
- s
Confirmed for 2019. In testing for 2007 to 2018, 2020 to 2026.
Driver presence 308_DRIVER_PRESENCEConfirmed
- Request
22 D7 23 - Service 22
DID D723 - Module
6A8 → 688 - Every
1 s - Testing for 2007 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 308.
Bits 0 to 7 of the reply, 8 bits.
0x01 = 1 → 1
- Formula
val- Range
- 0 to 255
- Unit
- Number
Confirmed for 2019. In testing for 2007 to 2018, 2020 to 2026.
Driver, requested torque value 308_DRIVER_REQ_TQConfirmed
- Request
22 D5 07 - Service 22
DID D507 - Module
6A9 → 689 - Every
250 ms - Testing for 2007 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 308.
Bits 0 to 7 of the reply, 8 bits.
0x29 = 41 → (41 × 2 − 100) = -18 N·m
- Formula
(val × 2 − 100)- Range
- -100 to 410 N·m
- Unit
- N·m
Confirmed for 2019. In testing for 2007 to 2018, 2020 to 2026.
Economy mode off state 308_ECO_MODE_OFF_STConfirmed
- Request
22 D7 24 - Service 22
DID D724 - Module
6A8 → 688 - Every
1 s - Testing for 2007 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 308.
Bits 0 to 7 of the reply, 8 bits.
0x00 = 0 → 0
- Formula
val- Range
- 0 to 255
- Unit
- Number
Confirmed for 2019. In testing for 2007 to 2018, 2020 to 2026.
Electric cooling fan control 308_GMV_ELEC_COOLING_FANConfirmed
- Request
22 D4 2F - Service 22
DID D42F - Module
6A8 → 688 - Every
1 s - Testing for 2007 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 308.
Bits 0 to 7 of the reply, 8 bits.
0x00 = 0 → 0
- Formula
val- Range
- 0 to 255
- Unit
- Number
Confirmed for 2019. In testing for 2007 to 2018, 2020 to 2026.
Energy accumulator state transfer 308_ENERGY_ACCUMULATOR_ST
- Request
22 D7 55 - Service 22
DID D755 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2007 to 2018, 2020 to 2026. Not supported for 2019.
Energy accumulator temperature limiter state 308_ENERGY_ACCUMULATOR_T
- Request
22 D7 58 - Service 22
DID D758 - Module
6A8 → 688 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2007 to 2018, 2020 to 2026. Not supported for 2019.
Engine control module status 308_ENG_CTRL_MODULE_STATConfirmed
- Request
22 DA DC - Service 22
DID DADC - Module
6A8 → 688 - Every
1 s - Testing for 2007 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 308.
Bits 0 to 7 of the reply, 8 bits.
0x00 = 0 → 0
- Formula
val- Range
- 0 to 255
- Unit
- Number
Confirmed for 2019. In testing for 2007 to 2018, 2020 to 2026.
Engine coolant temperature 308_ECT_6A9Confirmed
- Request
22 D5 55 - Service 22
DID D555 - Module
6A9 → 689 - Every
5 s - Testing for 2007 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 308.
Bits 0 to 7 of the reply, 8 bits.
0x60 = 96 → (96 − 40) = 56 °C
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2019. In testing for 2007 to 2018, 2020 to 2026.
Engine coolant temperature ECTSAE J1979Confirmed
Your engine temperature must operate within a certain temperature range to operate efficiently and safely. If it runs too hot, then your engine could be permanently damaged. If it runs too cold, then your engine will use more fuel than necessary.
Pelican can show this parameter as the engine coolant temperature.
- Request
01 05 - Service 01
PID 05 - Module
7E0 → 7E8 - Every
500 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2018 to 2019, 2024. Supported for 2010, 2016, 2022 to 2023, 2025.
Engine operating mode 308_ENG_OP_MODEConfirmed
- Request
22 D5 53 - Service 22
DID D553 - Module
6A9 → 689 - Every
1 s - Testing for 2007 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 308.
Bits 0 to 15 of the reply, 16 bits.
0x2D40 = 11584 → (11584 ÷ 8) = 1,448 rpm
- Formula
(val ÷ 8)- Range
- 0 to 8191 rpm
- Unit
- rpm
Confirmed for 2019. In testing for 2007 to 2018, 2020 to 2026.
Engine restart counter 308_ENG_RESTART_CNTConfirmed
- Request
22 D4 06 - Service 22
DID D406 - Module
6A9 → 689 - Every
3600 s - Testing for 2007 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 308.
Bits 0 to 31 of the reply, 32 bits.
0x00000000 = 0 → 0
- Formula
val- Range
- 0 to 4294967295
- Unit
- Number
Confirmed for 2019. In testing for 2007 to 2018, 2020 to 2026.
Engine restart counter by stop and start function 308_ENG_RESTART_CNT_STOP
- Request
22 D7 1B - Service 22
DID D71B - Module
6A8 → 688 - Every
3600 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
val- Range
- 0 to 4294967295
- Unit
- Number
In testing for 2007 to 2018, 2020 to 2026. Not supported for 2019.
Engine restart request sent by ESP computer 308_ENG_RESTART_REQ_SENTConfirmed
- Request
22 D7 0D - Service 22
DID D70D - Module
6A8 → 688 - Every
1 s - Testing for 2007 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 308.
Bits 0 to 7 of the reply, 8 bits.
0x00 = 0 → 0
- Formula
val- Range
- 0 to 255
- Unit
- Number
Confirmed for 2019. In testing for 2007 to 2018, 2020 to 2026.
Engine RPM RPMSAE J1979Confirmed
- Request
01 0C - Service 01
PID 0C - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4)- Range
- 0 to 16383.75 rpm
- Unit
- rpm
Confirmed for 2019, 2024. Supported for 2010, 2016, 2022 to 2023, 2025.
Engine stalls 308_ENG_STALLSConfirmed
- Request
22 D7 30 - Service 22
DID D730 - Module
6A9 → 689 - Every
1 s - Testing for 2007 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 308.
Bits 0 to 7 of the reply, 8 bits.
0x00 = 0 → 0
- Formula
val- Range
- 0 to 255
- Unit
- Number
Confirmed for 2019. In testing for 2007 to 2018, 2020 to 2026.
Engine start prohibition control, start lock 308_ENG_STARTConfirmed
- Request
22 D7 03 - Service 22
DID D703 - Module
6A9 → 689 - Every
1 s - Testing for 2007 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 308.
Bits 0 to 7 of the reply, 8 bits.
0x01 = 1 → 1
- Formula
val- Range
- 0 to 255
- Unit
- Number
Confirmed for 2019. In testing for 2007 to 2018, 2020 to 2026.
Engine stop time 308_ENG_STOP_TIMEConfirmed
- Request
22 D4 77 - Service 22
DID D477 - Module
6A8 → 688 - Every
1 s - Testing for 2007 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 308.
Bits 0 to 31 of the reply, 32 bits.
0x03251CDB = 52763867 → 52,763,867 s
- Formula
val- Range
- 0 to 4294967295 s
- Unit
- s
Confirmed for 2019. In testing for 2007 to 2018, 2020 to 2026.
Engine torque 308_ENG_TQ
- Request
21 C3 - Service 21
PID C3 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 112 to 119 of the reply, 8 bits.
- Formula
(val × 2 − 100)- Range
- -100 to 410 N·m
- Unit
- N·m
In testing for 2007 to 2018, 2020 to 2026. Not supported for 2019.
Estimated torque of internal friction of the engine 308_ESTIMATED_TQConfirmed
- Request
22 D4 E2 - Service 22
DID D4E2 - Module
6A8 → 688 - Every
250 ms - Testing for 2007 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 308.
Bits 0 to 15 of the reply, 16 bits.
0x00A8 = 168 → (168 ÷ 16) = 10.5 N·m
- Formula
(val ÷ 16)- Range
- 0 to 4095 N·m
- Unit
- N·m
Confirmed for 2019. In testing for 2007 to 2018, 2020 to 2026.
Expected generator supplier identifier of the reversible generator 308_EXPECTED_GEN
- Request
22 D7 89 - Service 22
DID D789 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2007 to 2018, 2020 to 2026. Not supported for 2019.
Expected identifier of electronic power circuit of reversible generator generator 308_EXPECTED_IDENTIFIER_ELECTRONIC
- Request
22 D7 88 - Service 22
DID D788 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2007 to 2018, 2020 to 2026. Not supported for 2019.
Expected identifier of reversible generator 308_EXPECTED_IDENTIFIER
- Request
22 D7 87 - Service 22
DID D787 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2007 to 2018, 2020 to 2026. Not supported for 2019.
Fuel rail pressure FRPSAE J1979Confirmed
Fuel rail pressure at the engine when the reading is referenced to atmosphere (gage pressure).
- Request
01 23 - Service 01
PID 23 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 10)- Range
- 0 to 655350 kPa
- Unit
- kPa
Confirmed for 2019, 2024. Supported for 2010, 2016, 2022 to 2023, 2025.
FUGITIVE TRIP IN EMERGENCY MODE 308_FUGITIVE_TRIPConfirmed
- Request
22 D6 71 - Service 22
DID D671 - Module
6A9 → 689 - Every
1 s - Testing for 2007 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 308.
Bits 0 to 7 of the reply, 8 bits.
0x00 = 0 → 0
- Formula
val- Range
- 0 to 255
- Unit
- Number
Confirmed for 2019. In testing for 2007 to 2018, 2020 to 2026.
Generator mode 308_GEN_MODE
- Request
22 D7 14 - Service 22
DID D714 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 75)- Range
- 0 to 19125 rpm
- Unit
- rpm
In testing for 2007 to 2018, 2020 to 2026. Not supported for 2019.
Generator shutdown 308_GEN_SHUTDOWN
- Request
22 D7 5B - Service 22
DID D75B - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2007 to 2018, 2020 to 2026. Not supported for 2019.
Identifier of the electronic power circuit of the reversible generator 308_IDENTIFIER
- Request
22 D7 32 - Service 22
DID D732 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2007 to 2018, 2020 to 2026. Not supported for 2019.
Identifier of the supplier of the reversible generator 308_IDENTIFIER_SUPPLIER
- Request
22 D7 33 - Service 22
DID D733 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2007 to 2018, 2020 to 2026. Not supported for 2019.
Immobilizer code programming status 308_IMMOBILIZER_CODEConfirmed
- Request
22 DA DC - Service 22
DID DADC - Module
6A8 → 688 - Every
1 s - Testing for 2007 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 308.
Bits 8 to 15 of the reply, 8 bits.
0x04 = 4 → 4
- Formula
val- Range
- 0 to 255
- Unit
- Number
Confirmed for 2019. In testing for 2007 to 2018, 2020 to 2026.
Indicated engine torque 308_INDICATED_ENG_TQConfirmed
- Request
22 D4 D2 - Service 22
DID D4D2 - Module
6A8 → 688 - Every
250 ms - Testing for 2007 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 308.
Bits 0 to 15 of the reply, 16 bits.
0x0000 = 0 → (0 ÷ 16) = 0 N·m
- Formula
(val ÷ 16)- Range
- 0 to 4095 N·m
- Unit
- N·m
Confirmed for 2019. In testing for 2007 to 2018, 2020 to 2026.
Intake air temperature IATSAE J1979Confirmed
- Request
01 0F - Service 01
PID 0F - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2019, 2024. Supported for 2010, 2016, 2022 to 2023, 2025.
Intake manifold absolute pressure MAPSAE J1979Confirmed
- Request
01 0B - Service 01
PID 0B - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 kPa
- Unit
- kPa
Confirmed for 2019, 2024. Supported for 2010, 2016, 2022 to 2023, 2025.
Line pressure solenoid valve control current 308_SLT_LINE_P_VARIATIONConfirmed
- Request
22 D6 06 - Service 22
DID D606 - Module
6A9 → 689 - Every
1 s - Testing for 2007 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 308.
Bits 0 to 7 of the reply, 8 bits.
0x1A = 26 → (26 × 10) = 260 mA
- Formula
(val × 10)- Range
- 0 to 2550 mA
- Unit
- mA
Confirmed for 2019. In testing for 2007 to 2018, 2020 to 2026.
Lock status 308_LOCK_STATConfirmed
- Request
22 DA DD - Service 22
DID DADD - Module
6A8 → 688 - Every
1 s - Testing for 2007 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 308.
Bits 0 to 7 of the reply, 8 bits.
0x00 = 0 → 0
- Formula
val- Range
- 0 to 255
- Unit
- Number
Confirmed for 2019. In testing for 2007 to 2018, 2020 to 2026.
Long term fuel trim (bank 1) LONGFT1SAE J1979Confirmed
- Request
01 07 - Service 01
PID 07 - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 128 − 100)- Range
- -100 to 99.2 %
- Unit
- %
Confirmed for 2019, 2024. Supported for 2010, 2016, 2022 to 2023, 2025.
Maximum allowable torque 308_MAX_ALLOWABLE_TQConfirmed
- Request
22 D5 06 - Service 22
DID D506 - Module
6A9 → 689 - Every
250 ms - Testing for 2007 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 308.
Bits 0 to 7 of the reply, 8 bits.
0x42 = 66 → (66 × 2 − 100) = 32 N·m
- Formula
(val × 2 − 100)- Range
- -100 to 410 N·m
- Unit
- N·m
Confirmed for 2019. In testing for 2007 to 2018, 2020 to 2026.
Measured current of electromagnetic valve for changing the pressure in the brake system B2 308_MEAS_CURRENT_P_B2Confirmed
- Request
22 D6 23 - Service 22
DID D623 - Module
6A9 → 689 - Every
250 ms - Testing for 2007 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 308.
Bits 0 to 7 of the reply, 8 bits.
0x08 = 8 → (8 × 10) = 80 mA
- Formula
(val × 10)- Range
- 0 to 2550 mA
- Unit
- mA
Confirmed for 2019. In testing for 2007 to 2018, 2020 to 2026.
Measured current of the electromagnetic valve for changing the pressure in the brake system B1 308_MEAS_CURRENT_P_B1Confirmed
- Request
22 D6 09 - Service 22
DID D609 - Module
6A9 → 689 - Every
250 ms - Testing for 2007 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 308.
Bits 0 to 7 of the reply, 8 bits.
0x08 = 8 → (8 × 10) = 80 mA
- Formula
(val × 10)- Range
- 0 to 2550 mA
- Unit
- mA
Confirmed for 2019. In testing for 2007 to 2018, 2020 to 2026.
Measured line pressure variation solenoid valve current 308_MEAS_LINE_PConfirmed
- Request
22 D6 07 - Service 22
DID D607 - Module
6A9 → 689 - Every
1 s - Testing for 2007 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 308.
Bits 0 to 7 of the reply, 8 bits.
0x1A = 26 → (26 × 10) = 260 mA
- Formula
(val × 10)- Range
- 0 to 2550 mA
- Unit
- mA
Confirmed for 2019. In testing for 2007 to 2018, 2020 to 2026.
Mileage since last oil change 308_MILEAGE_SINCE_OIL
- Request
22 D4 3F - Service 22
DID D43F - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 km
- Unit
- km
In testing for 2007 to 2018, 2020 to 2026. Not supported for 2019.
Neutral position sensor status 308_NEUTRAL_POS_SENSConfirmed
- Request
22 D4 38 - Service 22
DID D438 - Module
6A8 → 688 - Every
1 s - Testing for 2007 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 308.
Bits 0 to 7 of the reply, 8 bits.
0x00 = 0 → 0
- Formula
val- Range
- 0 to 255
- Unit
- Number
Confirmed for 2019. In testing for 2007 to 2018, 2020 to 2026.
Number of engine stop information deletion cycles 308_NUM_ENG_STOPConfirmed
- Request
22 D7 30 - Service 22
DID D730 - Module
6A9 → 689 - Every
1 s - Testing for 2007 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 308.
Bits 8 to 15 of the reply, 8 bits.
0x00 = 0 → 0
- Formula
val- Range
- 0 to 255
- Unit
- Number
Confirmed for 2019. In testing for 2007 to 2018, 2020 to 2026.
Oil pressure 308_OIL_PConfirmed
- Request
22 D4 29 - Service 22
DID D429 - Module
6A8 → 688 - Every
1 s - Testing for 2007 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 308.
Bits 0 to 15 of the reply, 16 bits.
0x47F3 = 18419 → (18419 ÷ 1000) = 18.419 bar
- Formula
(val ÷ 1000)- Range
- 0 to 65.53 bar
- Unit
- bar
Confirmed for 2019. In testing for 2007 to 2018, 2020 to 2026.
Oil pressure reference value 308_OIL_P_REFERENCEConfirmed
- Request
22 D4 64 - Service 22
DID D464 - Module
6A8 → 688 - Every
1 s - Testing for 2007 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 308.
Bits 0 to 15 of the reply, 16 bits.
0x0BCE = 3022 → (3022 ÷ 1000) = 3.022 bar
- Formula
(val ÷ 1000)- Range
- 0 to 65.53 bar
- Unit
- bar
Confirmed for 2019. In testing for 2007 to 2018, 2020 to 2026.
Oil pressure regulation control 308_OIL_P_REGULATIONConfirmed
- Request
22 D4 3B - Service 22
DID D43B - Module
6A8 → 688 - Every
1 s - Testing for 2007 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 308.
Bits 0 to 15 of the reply, 16 bits.
0x01A7 = 423 → (423 ÷ 10) = 42.3 %
- Formula
(val ÷ 10)- Range
- 0 to 6553 %
- Unit
- %
Confirmed for 2019. In testing for 2007 to 2018, 2020 to 2026.
Oil temperature 308_OIL_T
Pelican can show this parameter as the engine oil temperature.
- Request
22 D4 7D - Service 22
DID D47D - Module
6A8 → 688 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10 − 273.1400146)- Range
- -3549 to 3003 °C
- Unit
- °C
In testing for 2007 to 2018, 2020 to 2026. Not supported for 2019.
Outside air temperature 308_AAT_6A8Confirmed
- Request
22 D4 14 - Service 22
DID D414 - Module
6A8 → 688 - Every
5 s - Testing for 2007 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 308.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
0x000E = 14 → 14 °C
- Formula
val- Range
- -32768 to 32767 °C
- Unit
- °C
Confirmed for 2019. In testing for 2007 to 2018, 2020 to 2026.
Powertrain condition 308_POWERTRAIN_CONDConfirmed
- Request
22 D4 BA - Service 22
DID D4BA - Module
6A8 → 688 - Every
1 s - Testing for 2007 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 308.
Bits 0 to 7 of the reply, 8 bits.
0x01 = 1 → 1
- Formula
val- Range
- 0 to 255
- Unit
- Number
Confirmed for 2019. In testing for 2007 to 2018, 2020 to 2026.
Presence of the identifier of the reversible generator 308_PRESENCE_IDENTIFIER
- Request
22 D7 31 - Service 22
DID D731 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2007 to 2018, 2020 to 2026. Not supported for 2019.
Problems detected while transmitting unlock code 308_PROBLEMS_DETECTEDConfirmed
- Request
22 DA DC - Service 22
DID DADC - Module
6A8 → 688 - Every
1 s - Testing for 2007 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 308.
Bits 16 to 23 of the reply, 8 bits.
0x00 = 0 → 0
- Formula
val- Range
- 0 to 255
- Unit
- Number
Confirmed for 2019. In testing for 2007 to 2018, 2020 to 2026.
Problems detected while transmitting unlock code 308_PROBLEMS_DETECTED_WHILEConfirmed
- Request
22 DA DC - Service 22
DID DADC - Module
6A9 → 689 - Every
1 s - Testing for 2007 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 308.
Bits 16 to 23 of the reply, 8 bits.
0x00 = 0 → 0
- Formula
val- Range
- 0 to 255
- Unit
- Number
Confirmed for 2019. In testing for 2007 to 2018, 2020 to 2026.
Real engine torque 308_REAL_ENG_TQConfirmed
- Request
22 D5 54 - Service 22
DID D554 - Module
6A9 → 689 - Every
250 ms - Testing for 2007 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 308.
Bits 0 to 7 of the reply, 8 bits.
0x28 = 40 → (40 × 2 − 100) = -20 N·m
- Formula
(val × 2 − 100)- Range
- -100 to 410 N·m
- Unit
- N·m
Confirmed for 2019. In testing for 2007 to 2018, 2020 to 2026.
Remote wake-up circuit status 308_REMOTE_WAKE_UPConfirmed
- Request
22 D7 05 - Service 22
DID D705 - Module
6A9 → 689 - Every
1 s - Testing for 2007 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 308.
Bits 0 to 7 of the reply, 8 bits.
0x00 = 0 → 0
- Formula
val- Range
- 0 to 255
- Unit
- Number
Confirmed for 2019. In testing for 2007 to 2018, 2020 to 2026.
Remote wake-up state 308_REMOTE_WAKE_UP_STConfirmed
- Request
22 D7 08 - Service 22
DID D708 - Module
6A9 → 689 - Every
1 s - Testing for 2007 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 308.
Bits 0 to 7 of the reply, 8 bits.
0x02 = 2 → 2
- Formula
val- Range
- 0 to 255
- Unit
- Number
Confirmed for 2019. In testing for 2007 to 2018, 2020 to 2026.
Request to turn on the engine diagnostic indicator 308_REQ_TURN_ON_ENGConfirmed
- Request
22 D5 11 - Service 22
DID D511 - Module
6A9 → 689 - Every
1 s - Testing for 2007 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 308.
Bits 0 to 7 of the reply, 8 bits.
0x00 = 0 → 0
- Formula
val- Range
- 0 to 255
- Unit
- Number
Confirmed for 2019. In testing for 2007 to 2018, 2020 to 2026.
Requested value controlled thermostat 308_REQ_CONTROLLED
- Request
22 D5 86 - Service 22
DID D586 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 81.92000625)- Range
- -399 to 399 %
- Unit
- %
In testing for 2007 to 2018, 2020 to 2026. Not supported for 2019.
Restart request sent by power steering computer 308_RESTART_REQ_SENTConfirmed
- Request
22 D7 0C - Service 22
DID D70C - Module
6A8 → 688 - Every
250 ms - Testing for 2007 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 308.
Bits 0 to 7 of the reply, 8 bits.
0x00 = 0 → 0
- Formula
val- Range
- 0 to 255
- Unit
- Number
Confirmed for 2019. In testing for 2007 to 2018, 2020 to 2026.
Restart request sent by suspension computer 308_RESTART_REQ_SENT_SUSPENSION
- Request
22 D7 0E - Service 22
DID D70E - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2007 to 2018, 2020 to 2026. Not supported for 2019.
Return to engine start and restart control by starter 308_RETURN_ENG_STARTConfirmed
- Request
22 D7 64 - Service 22
DID D764 - Module
6A8 → 688 - Every
1 s - Testing for 2007 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 308.
Bits 0 to 7 of the reply, 8 bits.
0x02 = 2 → 2
- Formula
val- Range
- 0 to 255
- Unit
- Number
Confirmed for 2019. In testing for 2007 to 2018, 2020 to 2026.
Return to starter engine restart control 308_RETURN_STARTER_ENGConfirmed
- Request
22 D7 61 - Service 22
DID D761 - Module
6A8 → 688 - Every
1 s - Testing for 2007 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 308.
Bits 0 to 7 of the reply, 8 bits.
0x02 = 2 → 2
- Formula
val- Range
- 0 to 255
- Unit
- Number
Confirmed for 2019. In testing for 2007 to 2018, 2020 to 2026.
Reverse generator status 308_REVERSE_GEN_STAT
- Request
22 D7 16 - Service 22
DID D716 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2007 to 2018, 2020 to 2026. Not supported for 2019.
Reversible generator torque 308_REVERSIBLE_GEN_TQ
- Request
22 D7 15 - Service 22
DID D715 - Module
6A8 → 688 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 16)- Range
- -2048 to 2047 N·m
- Unit
- N·m
In testing for 2007 to 2018, 2020 to 2026. Not supported for 2019.
Service network related engine restart request 308_SERVICE_NETWORKConfirmed
- Request
22 D7 4B - Service 22
DID D74B - Module
6A8 → 688 - Every
1 s - Testing for 2007 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 308.
Bits 0 to 7 of the reply, 8 bits.
0x00 = 0 → 0
- Formula
val- Range
- 0 to 255
- Unit
- Number
Confirmed for 2019. In testing for 2007 to 2018, 2020 to 2026.
Short term fuel trim (bank 1) SHRTFT1SAE J1979Confirmed
Correction being used by the closed-loop fuel algorithm.
Pelican can show this parameter as the short term fuel trim.
- Request
01 06 - Service 01
PID 06 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 128 − 100)- Range
- -100 to 99.2 %
- Unit
- %
Confirmed for 2018 to 2019, 2024. Supported for 2010, 2016, 2022 to 2023, 2025.
Sport mode contactor state 308_SPORT_MODE_CONTACTORConfirmed
- Request
22 D5 03 - Service 22
DID D503 - Module
6A9 → 689 - Every
1 s - Testing for 2007 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 308.
Bits 0 to 7 of the reply, 8 bits.
0x00 = 0 → 0
- Formula
val- Range
- 0 to 255
- Unit
- Number
Confirmed for 2019. In testing for 2007 to 2018, 2020 to 2026.
Start inhibit control, wired 308_START_INHIBIT_CTRLConfirmed
- Request
22 D7 67 - Service 22
DID D767 - Module
6A8 → 688 - Every
1 s - Testing for 2007 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 308.
Bits 0 to 7 of the reply, 8 bits.
0x00 = 0 → 0
- Formula
val- Range
- 0 to 255
- Unit
- Number
Confirmed for 2019. In testing for 2007 to 2018, 2020 to 2026.
Start or restart inhibition transmitted by engine management computer 308_START_OR_RESTARTConfirmed
- Request
22 D7 1E - Service 22
DID D71E - Module
6A8 → 688 - Every
1 s - Testing for 2007 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 308.
Bits 0 to 7 of the reply, 8 bits.
0x01 = 1 → 1
- Formula
val- Range
- 0 to 255
- Unit
- Number
Confirmed for 2019. In testing for 2007 to 2018, 2020 to 2026.
Start prohibition 308_START_PROHIBITIONConfirmed
- Request
22 D5 1B - Service 22
DID D51B - Module
6A9 → 689 - Every
1 s - Testing for 2007 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 308.
Bits 0 to 7 of the reply, 8 bits.
0x01 = 1 → 1
- Formula
val- Range
- 0 to 255
- Unit
- Number
Confirmed for 2019. In testing for 2007 to 2018, 2020 to 2026.
Starter activation counter 308_STARTER_ACTIVATIONConfirmed
- Request
22 D7 1F - Service 22
DID D71F - Module
6A8 → 688 - Every
3600 s - Testing for 2007 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 308.
Bits 0 to 31 of the reply, 32 bits.
0x00004A6D = 19053 → 19,053
- Formula
val- Range
- 0 to 4294967295
- Unit
- Number
Confirmed for 2019. In testing for 2007 to 2018, 2020 to 2026.
Starter control interface unit operating status 308_STARTER_CTRLConfirmed
- Request
22 D7 2A - Service 22
DID D72A - Module
6A8 → 688 - Every
1 s - Testing for 2007 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 308.
Bits 0 to 7 of the reply, 8 bits.
0x01 = 1 → 1
- Formula
val- Range
- 0 to 255
- Unit
- Number
Confirmed for 2019. In testing for 2007 to 2018, 2020 to 2026.
Starter duty cycle 308_STARTER_DUTYConfirmed
- Request
22 D4 78 - Service 22
DID D478 - Module
6A8 → 688 - Every
1 s - Testing for 2007 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 308.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
0x0000 = 0 → (0 ÷ 10) = 0 s
- Formula
(val ÷ 10)- Range
- -3276 to 3276 s
- Unit
- s
Confirmed for 2019. In testing for 2007 to 2018, 2020 to 2026.
Starter engagement status 308_STARTER_ENGAGEMENTConfirmed
- Request
22 D4 C3 - Service 22
DID D4C3 - Module
6A8 → 688 - Every
1 s - Testing for 2007 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 308.
Bits 0 to 7 of the reply, 8 bits.
0x00 = 0 → 0
- Formula
val- Range
- 0 to 255
- Unit
- Number
Confirmed for 2019. In testing for 2007 to 2018, 2020 to 2026.
State lock/unlock control unit 308_ST_LOCK_UNLOCK_CTRLConfirmed
- Request
22 DA DC - Service 22
DID DADC - Module
6A9 → 689 - Every
1 s - Testing for 2007 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 308.
Bits 0 to 7 of the reply, 8 bits.
0x00 = 0 → 0
- Formula
val- Range
- 0 to 255
- Unit
- Number
Confirmed for 2019. In testing for 2007 to 2018, 2020 to 2026.
Status of internal ignition motor 308_STAT_INTERNAL_IGNConfirmed
- Request
22 D4 12 - Service 22
DID D412 - Module
6A8 → 688 - Every
1 s - Testing for 2007 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 308.
Bits 0 to 7 of the reply, 8 bits.
0x05 = 5 → 5
- Formula
val- Range
- 0 to 255
- Unit
- Number
Confirmed for 2019. In testing for 2007 to 2018, 2020 to 2026.
Status of the energy accumulator 308_STAT_ENERGY
- Request
22 D7 22 - Service 22
DID D722 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 %
- Unit
- %
In testing for 2007 to 2018, 2020 to 2026. Not supported for 2019.
Stop allowed by ESP computer 308_STOP_ALLOWED_ESPConfirmed
- Request
22 D7 06 - Service 22
DID D706 - Module
6A8 → 688 - Every
1 s - Testing for 2007 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 308.
Bits 0 to 7 of the reply, 8 bits.
0x01 = 1 → 1
- Formula
val- Range
- 0 to 255
- Unit
- Number
Confirmed for 2019. In testing for 2007 to 2018, 2020 to 2026.
Stop and start function state 308_STOP_START_FUNCTIONConfirmed
- Request
22 D7 25 - Service 22
DID D725 - Module
6A8 → 688 - Every
1 s - Testing for 2007 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 308.
Bits 0 to 7 of the reply, 8 bits.
0x09 = 9 → 9
- Formula
val- Range
- 0 to 255
- Unit
- Number
Confirmed for 2019. In testing for 2007 to 2018, 2020 to 2026.
Stop and start switch 308_STOP_START_SWITCHConfirmed
- Request
22 D7 26 - Service 22
DID D726 - Module
6A8 → 688 - Every
1 s - Testing for 2007 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 308.
Bits 0 to 7 of the reply, 8 bits.
0x00 = 0 → 0
- Formula
val- Range
- 0 to 255
- Unit
- Number
Confirmed for 2019. In testing for 2007 to 2018, 2020 to 2026.
Stop permitted by suspension computer 308_STOP_PERMITTED
- Request
22 D7 07 - Service 22
DID D707 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2007 to 2018, 2020 to 2026. Not supported for 2019.
Temperature of the energy accumulator 308_T_ENERGY_ACCUMULATOR
- Request
22 D7 21 - Service 22
DID D721 - Module
6A8 → 688 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 2)- Range
- -16384 to 16383 °C
- Unit
- °C
In testing for 2007 to 2018, 2020 to 2026. Not supported for 2019.
The composition of the mixture is calculated by the oxygen sensor 308_COMPOSITION_MIXTURE
- Request
22 D5 70 - Service 22
DID D570 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 32786.88588)- Range
- 0 to 1.99
- Unit
- Number
In testing for 2007 to 2018, 2020 to 2026. Not supported for 2019.
Timing advance SPARKADVSAE J1979Confirmed
Ignition timing spark advance for the first cylinder. Measured in degrees before dead center. Minus is degrees before dead center, positive is degrees after.
- Request
01 0E - Service 01
PID 0E - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 2 − 64)- Range
- -64 to 63.5 °
- Unit
- °
Confirmed for 2019, 2024. Supported for 2010, 2016, 2022 to 2023, 2025.
Torque corresponding to driver requirement 308_TQ_CORRESPONDINGConfirmed
- Request
22 D4 E3 - Service 22
DID D4E3 - Module
6A8 → 688 - Every
250 ms - Testing for 2007 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 308.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
0x013B = 315 → (315 ÷ 16) = 19.6875 N·m
- Formula
(val ÷ 16)- Range
- -2048 to 2047 N·m
- Unit
- N·m
Confirmed for 2019. In testing for 2007 to 2018, 2020 to 2026.
Torque supplied or taken by generator 308_TQ_SUPPLIED_OR_TAKENConfirmed
- Request
22 D7 28 - Service 22
DID D728 - Module
6A8 → 688 - Every
250 ms - Testing for 2007 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 308.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
0x0010 = 16 → (16 ÷ 16) = 1 N·m
- Formula
(val ÷ 16)- Range
- -2048 to 2047 N·m
- Unit
- N·m
Confirmed for 2019. In testing for 2007 to 2018, 2020 to 2026.
Total mileage 308_ODO_6A8
Pelican can show this parameter as the odometer.
- Request
22 D4 9C - Service 22
DID D49C - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
val- Range
- 0 to 4294967295 km
- Unit
- km
In testing for 2007 to 2018, 2020 to 2026. Not supported for 2019.
Towing device configured 308_CAN_VEH_BE_EQUIPPED
- Request
22 D5 57 - Service 22
DID D557 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2007 to 2018, 2020 to 2026. Not supported for 2019.
Traction or stability control regulating 308_ASR_OR_ESP_SYSTEMConfirmed
- Request
22 D5 12 - Service 22
DID D512 - Module
6A9 → 689 - Every
1 s - Testing for 2007 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 308.
Bits 0 to 7 of the reply, 8 bits.
0x00 = 0 → 0
- Formula
val- Range
- 0 to 255
- Unit
- Number
Confirmed for 2019. In testing for 2007 to 2018, 2020 to 2026.
Transmission fluid temperature 308_ATF_T
Pelican can show this parameter as the transmission fluid temperature.
- Request
21 C5 - Service 21
PID C5 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 168 to 175 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2007 to 2018, 2020 to 2026. Not supported for 2019.
Type of fuel currently being used by the vehicle FUEL_TYPSAE J1979Confirmed
- Request
01 51 - Service 01
PID 51 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
1 | GAS | Gasoline/petrol |
2 | METH | Methanol |
3 | ETH | Ethanol |
4 | DSL | Diesel |
5 | LPG | Liquefied petroleum gas |
6 | CNG | Compressed natural gas |
7 | PROP | Propane |
8 | ELEC | Battery/electric |
9 | BI_GAS | Bi-fuel vehicle using gasoline/petrol |
10 | BI_METH | Bi-fuel vehicle using methanol |
11 | BI_ETH | Bi-fuel vehicle using ethanol |
12 | BI_LPG | Bi-fuel vehicle using LPG |
13 | BI_CNG | Bi-fuel vehicle using CNG |
14 | BI_PROP | Bi-fuel vehicle using propane |
15 | BI_ELEC | Bi-fuel vehicle using battery |
16 | BI_MIX | Bi-fuel vehicle using battery and combustion engine for propulsion |
17 | HYB_GAS | Hybrid vehicle using gasoline engine for propulsion |
18 | HYB_ETH | Hybrid vehicle using gasoline engine on ethanol for propulsion |
19 | HYB_DSL | Hybrid vehicle using diesel engine for propulsion |
20 | HYB_ELEC | Hybrid vehicle using battery for propulsion |
21 | HYB_MIX | Hybrid vehicle using battery and combustion engine for propulsion |
22 | HYB_REG | Hybrid vehicle in regeneration mode |
23 | BI_DSL | Bi-fuel vehicle using diesel |
24 | BI_NG | Bi-fuel vehicle using natural gas |
25 | BI_DSL | Bi-fuel vehicle using diesel |
26 | NG | Natural gas |
27 | DSL_CNG | Dual fuel vehicle using diesel and CNG |
28 | DSL_LNG | Dual fuel vehicle using diesel and LNG |
29 | FC_H2 | Fuel cell utilizing hydrogen |
30 | HICE_HHO | Hydrogen Internal Combustion Engine |
31 | KERO | Kerosene |
32 | HFO | Heavy Fuel Oil |
Confirmed for 2019, 2024. Supported for 2025.
Vacuum circuit vacuum 308_VACUUM_CIRCUIT
- Request
22 D7 3B - Service 22
DID D73B - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Raw value
In testing for 2007 to 2018, 2020 to 2026. Not supported for 2019.
Value during generator load smooth increase 308_DURING_GEN_LOADConfirmed
- Request
22 D7 53 - Service 22
DID D753 - Module
6A8 → 688 - Every
1 s - Testing for 2007 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 308.
Bits 0 to 7 of the reply, 8 bits.
0x05 = 5 → 5
- Formula
val- Range
- 0 to 255
- Unit
- Number
Confirmed for 2019. In testing for 2007 to 2018, 2020 to 2026.
Vehicle hour meter 308_VEH_HOUR_METERConfirmed
- Request
22 D8 01 - Service 22
DID D801 - Module
6A9 → 689 - Every
1 s - Testing for 2007 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 308.
Bits 0 to 31 of the reply, 32 bits.
0x1F732A0A = 527641098 → (527641098 ÷ 10) = 52,764,109.8 s
- Formula
(val ÷ 10)- Range
- 0 to 429496729 s
- Unit
- s
Confirmed for 2019. In testing for 2007 to 2018, 2020 to 2026.
Vehicle mileage since the last oil change under severe vehicle operating conditions 308_VEH_MILEAGE_SINCE
- Request
22 D5 34 - Service 22
DID D534 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553 km
- Unit
- km
In testing for 2007 to 2018, 2020 to 2026. Not supported for 2019.
Wastegate A position WG_A_ACTSAE J1979Confirmed
If an on/off solenoid is used, is 0% when the wastegate is commanded off (allow full boost), 100% when commanded on (dump boost). If a vacuum solenoid is duty cycled, the duty cycle from 0 to 100% is displayed. If a linear or stepper motor valve is used, the fully closed position (full boost) is displayed as 0%, the fully open position (dump boost) is displayed as 100%. Intermediate positions are displayed as a percent of the full-open position. Any other actuation method is normalized to display 0% when the WG is commanded off and 100% when the WG is commanded on.
- Request
01 72 - Service 01
PID 72 - Module
7E0 → 7E8 - Every
250 ms
Bits 16 to 23 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2019.
Wastegate B position WG_B_ACTSAE J1979Confirmed
If an on/off solenoid is used, is 0% when the wastegate is commanded off (allow full boost), 100% when commanded on (dump boost). If a vacuum solenoid is duty cycled, the duty cycle from 0 to 100% is displayed. If a linear or stepper motor valve is used, the fully closed position (full boost) is displayed as 0%, the fully open position (dump boost) is displayed as 100%. Intermediate positions are displayed as a percent of the full-open position. Any other actuation method is normalized to display 0% when the WG is commanded off and 100% when the WG is commanded on.
- Request
01 72 - Service 01
PID 72 - Module
7E0 → 7E8 - Every
250 ms
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2019.
Winter mode switch state 308_WINTER_MODE_SWITCHConfirmed
- Request
22 D5 02 - Service 22
DID D502 - Module
6A9 → 689 - Every
1 s - Testing for 2007 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 308.
Bits 0 to 7 of the reply, 8 bits.
0x00 = 0 → 0
- Formula
val- Range
- 0 to 255
- Unit
- Number
Confirmed for 2019. In testing for 2007 to 2018, 2020 to 2026.
Engine › Internal
Commanded wastegate A position supported WG_A_CMD_SUPSAE J1979Confirmed
- Request
01 72 - Service 01
PID 72 - Module
7E0 → 7E8 - Every
250 ms
Bit 7 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2019.
Commanded wastegate B position supported WG_B_CMD_SUPSAE J1979Confirmed
- Request
01 72 - Service 01
PID 72 - Module
7E0 → 7E8 - Every
250 ms
Bit 5 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2019.
Maximum value for air flow rate from mass air flow sensor MAX_MAFSAE J1979Confirmed
- Request
01 50 - Service 01
PID 50 - Module
7E0 → 7E8 - Every
3600 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 10)- Range
- 0 to 2550 g/s
- Unit
- g/s
Confirmed for 2019.
Maximum value for equivalence ratio MAX_EQ_RATSAE J1979Confirmed
- Request
01 4F - Service 01
PID 4F - Module
7E0 → 7E8 - Every
3600 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
Confirmed for 2019.
Maximum value for intake manifold absolute pressure (MAP) MAX_MAPSAE J1979Confirmed
- Request
01 4F - Service 01
PID 4F - Module
7E0 → 7E8 - Every
3600 s
Bits 24 to 31 of the reply, 8 bits.
- Formula
(val × 10)- Range
- 0 to 2550 kPa
- Unit
- kPa
Confirmed for 2019.
Maximum value for oxygen sensor current MAX_O2_CURRSAE J1979Confirmed
- Request
01 4F - Service 01
PID 4F - Module
7E0 → 7E8 - Every
3600 s
Bits 16 to 23 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 mA
- Unit
- mA
Confirmed for 2019.
Maximum value for oxygen sensor voltage MAX_O2_VOLTSAE J1979Confirmed
- Request
01 4F - Service 01
PID 4F - Module
7E0 → 7E8 - Every
3600 s
Bits 8 to 15 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 V
- Unit
- V
Confirmed for 2019.
Wastegate A position supported WG_A_ACT_SUPSAE J1979Confirmed
- Request
01 72 - Service 01
PID 72 - Module
7E0 → 7E8 - Every
250 ms
Bit 6 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2019.
Wastegate B position supported WG_B_ACT_SUPSAE J1979Confirmed
- Request
01 72 - Service 01
PID 72 - Module
7E0 → 7E8 - Every
250 ms
Bit 4 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2019.
Engine › OxygenSensors
02S Bank 1, Sensor 1 present O2S11_EXISTSSAE J1979Confirmed
- Request
01 13 - Service 01
PID 13 - Module
7E0 → 7E8 - Every
3600 s
Bit 7 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2019. Supported for 2010, 2016, 2022 to 2025.
02S Bank 1, Sensor 2 present O2S12_EXISTSSAE J1979Confirmed
- Request
01 13 - Service 01
PID 13 - Module
7E0 → 7E8 - Every
3600 s
Bit 6 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2019. Supported for 2010, 2016, 2022 to 2025.
02S Bank 1, Sensor 3 present O2S13_EXISTSSAE J1979Confirmed
- Request
01 13 - Service 01
PID 13 - Module
7E0 → 7E8 - Every
3600 s
Bit 5 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2019. Supported for 2010, 2016, 2022 to 2025.
02S Bank 1, Sensor 4 present O2S14_EXISTSSAE J1979Confirmed
- Request
01 13 - Service 01
PID 13 - Module
7E0 → 7E8 - Every
3600 s
Bit 4 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2019. Supported for 2010, 2016, 2022 to 2025.
02S Bank 2, Sensor 1 present O2S21_EXISTSSAE J1979Confirmed
- Request
01 13 - Service 01
PID 13 - Module
7E0 → 7E8 - Every
3600 s
Bit 3 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2019. Supported for 2010, 2016, 2022 to 2025.
02S Bank 2, Sensor 2 present O2S22_EXISTSSAE J1979Confirmed
- Request
01 13 - Service 01
PID 13 - Module
7E0 → 7E8 - Every
3600 s
Bit 2 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2019. Supported for 2010, 2016, 2022 to 2025.
02S Bank 2, Sensor 3 present O2S23_EXISTSSAE J1979Confirmed
- Request
01 13 - Service 01
PID 13 - Module
7E0 → 7E8 - Every
3600 s
Bit 1 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2019. Supported for 2010, 2016, 2022 to 2025.
02S Bank 2, Sensor 4 present O2S24_EXISTSSAE J1979Confirmed
- Request
01 13 - Service 01
PID 13 - Module
7E0 → 7E8 - Every
3600 s
Bit 0 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2019. Supported for 2010, 2016, 2022 to 2025.
Lambda value, Equivalence Ratio Bank 1, Sensor 1 LAMBDA11_CURRENTSAE J1979Confirmed
Pelican can show this parameter as the O2 lambda.
- Request
01 34 - Service 01
PID 34 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 32768)- Range
- 0 to 1.99
- Unit
- Number
Confirmed for 2018 to 2019, 2024. Supported for 2010, 2022 to 2023, 2025.
O2S Output Voltage Bank 1, Sensor 1 O2S11SAE J1979Confirmed
- Request
01 14 - Service 01
PID 14 - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 200)- Range
- 0 to 1.275 V
- Unit
- V
Confirmed for 2019. Supported for 2010.
O2S Output Voltage Bank 1, Sensor 2 O2S12SAE J1979Confirmed
- Request
01 15 - Service 01
PID 15 - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 200)- Range
- 0 to 1.275 V
- Unit
- V
Confirmed for 2019. Supported for 2010, 2016, 2022 to 2025.
SHRTFT associated with O2S11 SHRTFT11SAE J1979Confirmed
- Request
01 14 - Service 01
PID 14 - Module
7E0 → 7E8 - Every
1 s
Bits 8 to 15 of the reply, 8 bits.
- Formula
(val × 100 ÷ 128 − 128)- Range
- -100 to 99.22 %
- Unit
- %
Confirmed for 2019. Supported for 2010, 2016, 2022 to 2025.
Wide Range O2S Current, O2 Sensor Bank 1, Sensor 1 O2S11_CURRENTSAE J1979Confirmed
- Request
01 34 - Service 01
PID 34 - Module
7E0 → 7E8 - Every
250 ms
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val ÷ 256 − 128)- Range
- -128 to 127.996 mA
- Unit
- mA
Confirmed for 2018 to 2019, 2024. Supported for 2010, 2022 to 2023, 2025.