Battery parameters
The Nissan X-Trail has 15 battery parameters.
● Confirmed◆ In testing○ Supported× Not supported
Accelerator pedal position sensor 1, volts XTRAIL_ACCEL_PEDAL_POS_SENS_1
- Request
22 12 0D - Service 22
DID 120D - Module
DA18 → 18 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 200)- Range
- 0 to 327 V
- Unit
- V
In testing for 2021 to 2026.
Accelerator pedal position sensor 2, volts XTRAIL_ACCEL_PEDAL_POS_SENS_2
- Request
22 12 0E - Service 22
DID 120E - Module
DA18 → 18 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 200)- Range
- 0 to 327 V
- Unit
- V
In testing for 2021 to 2026.
ALTERNATOR set point VOLTAGE XTRAIL_ALTERNATOR_SETPOINT_V
- Request
21 69 - Service 21
PID 69 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 50)- Range
- 0 to 1310 V
- Unit
- V
In testing for 2001 to 2017, 2019 to 2026. Not supported for 2018.
Control module voltage VPWRSAE J1979Confirmed
Power input to the OBD control module. VPWR is normally battery voltage, less any voltage drop in the circuit between the battery and the control module.
Pelican can show this parameter as the starter battery voltage.
- Request
01 42 - Service 01
PID 42 - Module
7E0 → 7E8 - Every
10 s
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65535 V
- Unit
- V
Confirmed for 2024 to 2025. Supported for 2016 to 2018, 2021, 2023.
EVAP pressure sensor voltage XTRAIL_EVAP_P_SENS_V
- Request
22 11 15 - Service 22
DID 1115 - Module
DA18 → 18 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2021 to 2026.
Exhaust gas recirculation temperature sensor voltage XTRAIL_EGR_T_SENS_V
- Request
22 11 05 - Service 22
DID 1105 - Module
DA18 → 18 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2021 to 2026.
Fuel pressure sensor voltage XTRAIL_FUEL_P_SENS_V
- Request
22 12 0C - Service 22
DID 120C - Module
DA18 → 18 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 4 ÷ 13107)- Range
- 0 to 20 V
- Unit
- V
In testing for 2021 to 2026.
Fuel rail temperature sensor voltage XTRAIL_FUEL_RAIL_T_SENS_V
- Request
21 AD - Service 21
PID AD - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
(val × 5 ÷ 256)- Range
- 0 to 4.98 V
- Unit
- V
In testing for 2001 to 2017, 2019 to 2026. Not supported for 2018.
Fuel tank temperature sensor voltage XTRAIL_FUEL_TANK_T_SENS_V
- Request
21 AD - Service 21
PID AD - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val × 5 ÷ 256)- Range
- 0 to 4.98 V
- Unit
- V
In testing for 2001 to 2017, 2019 to 2026. Not supported for 2018.
Manifold pressure sensor voltage XTRAIL_MANIFOLD_P_SENS_V
- Request
22 11 2A - Service 22
DID 112A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2001 to 2017, 2019 to 2026. Not supported for 2018.
Refrigerant fluid sensor voltage XTRAIL_REFRIGERANT_FLUID_V
- Request
22 12 23 - Service 22
DID 1223 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 200)- Range
- 0 to 327 V
- Unit
- V
In testing for 2001 to 2017, 2019 to 2026. Not supported for 2018.
Roll-over sensor voltage XTRAIL_ROLL_OVER_SENS_V
- Request
22 12 1F - Service 22
DID 121F - Module
DA18 → 18 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 200)- Range
- 0 to 327 V
- Unit
- V
In testing for 2021 to 2026.
Throttle position sensor 1, volts XTRAIL_THROTTLE_POS_SENS_1
- Request
22 12 0F - Service 22
DID 120F - Module
DA18 → 18 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 200)- Range
- 0 to 327 V
- Unit
- V
In testing for 2021 to 2026.
Throttle position sensor 2, volts XTRAIL_THROTTLE_POS_SENS_2
- Request
22 12 10 - Service 22
DID 1210 - Module
DA18 → 18 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 200)- Range
- 0 to 327 V
- Unit
- V
In testing for 2021 to 2026.
Upstream oxygen sensor voltage XTRAIL_UP_OXYGEN_SENS_V
- Request
22 12 25 - Service 22
DID 1225 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 200)- Range
- 0 to 327 V
- Unit
- V
In testing for 2001 to 2017, 2019 to 2026. Not supported for 2018.