Climate parameters
The Nissan Rogue has 16 climate parameters.
● Confirmed◆ In testing○ Supported× Not supported
A/C state NISSAN_AC_ON
- Request
22 11 06 - Service 22
DID 1106 - Module
797 → 79A - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2008 to 2009, 2011 to 2013, 2016 to 2017. Not supported for 2010, 2014 to 2015, 2018 to 2026.
Air conditioning compressor speed NISSAN_AC_COMP_RPM
- Request
21 10 - Service 21
PID 10 - Module
744 → 764 - Every
5 s - Testing
Bits 168 to 183 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 rpm
- Unit
- rpm
In testing for 2008 to 2026.
Air conditioning on NISSAN_HVAC_AC_ON
- Request
21 10 - Service 21
PID 10 - Module
744 → 764 - Every
5 s - Testing
Bit 80 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2008 to 2026.
Air conditioning status NISSAN_AC_STATUSConfirmed
- Request
22 40 07 - Service 22
DID 4007 - Module
744 → 764 - Every
5 s - Testing
Example reply from a 2024 Nissan Rogue.
Bits 0 to 7 of the reply, 8 bits.
0x89 = 137 → 137
- Formula
val- Range
- 0 to 255
- Unit
- Off or on
Confirmed for 2021 to 2022, 2024. In testing for 2008 to 2009, 2011 to 2013, 2016 to 2017, 2023, 2025. Not supported for 2010, 2014 to 2015, 2018 to 2020, 2026.
Ambient air temperature AATSAE J1979Confirmed
- Request
01 46 - Service 01
PID 46 - Module
7E0 → 7E8 - Every
15 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2018. Supported for 2019, 2021 to 2026.
Ambient air temperature NISSAN_AATConfirmed
- Request
22 40 08 - Service 22
DID 4008 - Module
744 → 764 - Every
5 s - Testing
Example reply from a 2024 Nissan Rogue.
Bits 0 to 7 of the reply, 8 bits.
0x28 = 40 → (40 − 40) = 0 °C
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2021 to 2022, 2024. In testing for 2008 to 2009, 2011 to 2013, 2016 to 2017, 2023, 2025. Not supported for 2010, 2014 to 2015, 2018 to 2020, 2026.
Ambient air temperature NISSAN_AAT_V2
- Request
22 11 5D - Service 22
DID 115D - Module
797 → 79A - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 0.9 − 40.9)- Range
- -36.81 to 192.69 °F
- Unit
- °F
In testing for 2008 to 2009, 2011 to 2013, 2016 to 2017. Not supported for 2010, 2014 to 2015, 2018 to 2026.
Ambient air temperature, climate module NISSAN_HVAC_AAT
- Request
21 10 - Service 21
PID 10 - Module
744 → 764 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2008 to 2026.
Blower on NISSAN_HVAC_FAN_ON
- Request
21 10 - Service 21
PID 10 - Module
744 → 764 - Every
5 s - Testing
Bit 88 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2008 to 2026.
Blower voltage NISSAN_HVAC_BLOWER_V
- Request
21 10 - Service 21
PID 10 - Module
744 → 764 - Every
5 s - Testing
Bits 89 to 95 of the reply, 7 bits.
- Formula
val- Range
- 0 to 127 V
- Unit
- V
In testing for 2008 to 2026.
Cabin temperature NISSAN_HVAC_CABIN_T
- Request
21 10 - Service 21
PID 10 - Module
744 → 764 - Every
5 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2008 to 2026.
Coolant temperature NISSAN_ECTConfirmed
- Request
22 F4 67 - Service 22
DID F467 - Module
744 → 764 - Every
5 s - Testing
Example reply from a 2024 Nissan Rogue.
Bits 0 to 7 of the reply, 8 bits.
0x73 = 115 → (115 − 40) = 75 °C
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2021 to 2022, 2024. In testing for 2008 to 2009, 2011 to 2013, 2016 to 2017, 2023, 2025. Not supported for 2010, 2014 to 2015, 2018 to 2020, 2026.
ECO mode state NISSAN_ECO_MODE
- Request
22 13 18 - Service 22
DID 1318 - Module
797 → 79A - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
0 | ECO_OFF | ECO is off |
16 | ECO_ON_1 | ECO is on |
17 | ECO_ON_2 | ECO is on |
In testing for 2008 to 2009, 2011 to 2013, 2016 to 2017. Not supported for 2010, 2014 to 2015, 2018 to 2026.
Evaporator temperature NISSAN_HVAC_EVAP_T
- Request
21 10 - Service 21
PID 10 - Module
744 → 764 - Every
5 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2008 to 2026.
Rear heater state NISSAN_HTR_REAR
- Request
22 11 0F - Service 22
DID 110F - Module
797 → 79A - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
162 | HEATER_ON | Heater is on |
In testing for 2008 to 2009, 2011 to 2013, 2016 to 2017. Not supported for 2010, 2014 to 2015, 2018 to 2026.
Sun load NISSAN_HVAC_SUNLOAD
- Request
21 10 - Service 21
PID 10 - Module
744 → 764 - Every
5 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2008 to 2026.