Nissan Armada

Climate parameters

The Nissan Armada has 12 climate parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

A/C status ARMADA_AC_STATUSConfirmed

  • Request22 40 07
  • Service 22DID 4007
  • Module744 → 764
  • Every1 s
  • Testing for 2004 to 2015, 2017 to 2024

Example reply from a 2026 Nissan Armada.

Bits 0 to 7 of the reply, 8 bits.

0x00 = 0 → 0

Formula
val
Range
0 to 255
Unit
Off or on

Confirmed for 2025 to 2026. In testing for 2004 to 2015, 2018 to 2019, 2022, 2024. Not supported for 2017, 2020 to 2021, 2023.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

A/C status ARMADA_AC_STATUSConfirmed

  • Request22 40 07
  • Service 22DID 4007
  • Module744 → 764
  • Every1 s
  • Testing for 2004 to 2015, 2017 to 2024

Example reply from a 2026 Nissan Armada.

Bits 0 to 7 of the reply, 8 bits.

0x00 = 0 → 0

Formula
val
Range
0 to 255
Unit
Off or on

Confirmed for 2025 to 2026. In testing for 2004 to 2015, 2018 to 2019, 2022, 2024. Not supported for 2017, 2020 to 2021, 2023.

Air conditioning compressor speed ARMADA_AC_COMP_RPM

  • Request21 10
  • Service 21PID 10
  • Module744 → 764
  • Every5 s
  • Testing

Bits 168 to 183 of the reply, 16 bits.

Formula
val
Range
0 to 65535 rpm
Unit
rpm

In testing for 2004 to 2015, 2018 to 2025. Not supported for 2017, 2026.

Air conditioning on ARMADA_HVAC_AC_ON

  • Request21 10
  • Service 21PID 10
  • Module744 → 764
  • Every5 s
  • Testing

Bit 80 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2004 to 2015, 2018 to 2025. Not supported for 2017, 2026.

Ambient air temperature AATSAE J1979Confirmed

  • Request01 46
  • Service 01PID 46
  • Module7E0 → 7E8
  • Every15 s

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2017. Supported for 2025 to 2026.

Ambient air temperature ARMADA_AATConfirmed

  • Request22 40 08
  • Service 22DID 4008
  • Module744 → 764
  • Every1 s
  • Testing for 2004 to 2015, 2017 to 2024

Example reply from a 2026 Nissan Armada.

Bits 0 to 7 of the reply, 8 bits.

0x28 = 40 → (40 − 40) = 0 °C

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2025 to 2026. In testing for 2004 to 2015, 2018 to 2019, 2022, 2024. Not supported for 2017, 2020 to 2021, 2023.

Ambient air temperature, climate module ARMADA_HVAC_AAT

  • Request21 10
  • Service 21PID 10
  • Module744 → 764
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2004 to 2015, 2018 to 2025. Not supported for 2017, 2026.

Blower on ARMADA_HVAC_FAN_ON

  • Request21 10
  • Service 21PID 10
  • Module744 → 764
  • Every5 s
  • Testing

Bit 88 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2004 to 2015, 2018 to 2025. Not supported for 2017, 2026.

Blower voltage ARMADA_HVAC_BLOWER_V

  • Request21 10
  • Service 21PID 10
  • Module744 → 764
  • Every5 s
  • Testing

Bits 89 to 95 of the reply, 7 bits.

Formula
val
Range
0 to 127 V
Unit
V

In testing for 2004 to 2015, 2018 to 2025. Not supported for 2017, 2026.

Cabin temperature ARMADA_HVAC_CABIN_T

  • Request21 10
  • Service 21PID 10
  • Module744 → 764
  • Every5 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2004 to 2015, 2018 to 2025. Not supported for 2017, 2026.

Engine coolant temperature ARMADA_ECTConfirmed

  • Request22 F4 67
  • Service 22DID F467
  • Module744 → 764
  • Every1 s
  • Testing for 2004 to 2015, 2017 to 2024

Example reply from a 2026 Nissan Armada.

Bits 0 to 7 of the reply, 8 bits.

0x47 = 71 → (71 − 40) = 31 °C

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2025 to 2026. In testing for 2004 to 2015, 2018 to 2019, 2022, 2024. Not supported for 2017, 2020 to 2021, 2023.

Evaporator temperature ARMADA_HVAC_EVAP_T

  • Request21 10
  • Service 21PID 10
  • Module744 → 764
  • Every5 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2004 to 2015, 2018 to 2025. Not supported for 2017, 2026.

Sun load ARMADA_HVAC_SUNLOAD

  • Request21 10
  • Service 21PID 10
  • Module744 → 764
  • Every5 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2004 to 2015, 2018 to 2025. Not supported for 2017, 2026.

Keyboard shortcuts

jk/↓↑
Move down or up through a list or a grid.
hl/←→
Move across a row or between cards.
Enter
Open the focused link.
f
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?