MG HS

Door parameters

The MG HS has 8 door parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

Door open, bonnet MG_DOOR_BONNET

  • Request22 D1 12
  • Service 22DID D112
  • Module7E3
  • Every1 s
  • Testing

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

In testing for 2018 to 2026.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Door open, bonnet MG_DOOR_BONNET

  • Request22 D1 12
  • Service 22DID D112
  • Module7E3
  • Every1 s
  • Testing

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

In testing for 2018 to 2026.

Door open, boot MG_DOOR_BOOT

  • Request22 D1 12
  • Service 22DID D112
  • Module7E3
  • Every1 s
  • Testing

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

In testing for 2018 to 2026.

Door open, driver MG_DOOR_DRIVER

  • Request22 D1 12
  • Service 22DID D112
  • Module7E3
  • Every1 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

In testing for 2018 to 2026.

Door open, LH rear MG_DOOR_LH_REAR

  • Request22 D1 12
  • Service 22DID D112
  • Module7E3
  • Every1 s
  • Testing

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

In testing for 2018 to 2026.

Door open, passenger MG_DOOR_PASSENGER

  • Request22 D1 12
  • Service 22DID D112
  • Module7E3
  • Every1 s
  • Testing

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

In testing for 2018 to 2026.

Door open, RH rear MG_DOOR_RH_REAR

  • Request22 D1 12
  • Service 22DID D112
  • Module7E3
  • Every1 s
  • Testing

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

In testing for 2018 to 2026.

Hood open MG_HOOD

  • Request22 BB 06
  • Service 22DID BB06
  • Module7E3 → 7EB
  • Every5 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

In testing for 2018 to 2026.

Vehicle unlocked MG_UNLOCKED

  • Request22 B0 13
  • Service 22DID B013
  • Module745 → 74D
  • Every5 s
  • Testing

Bit 31 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

In testing for 2018 to 2026.

Keyboard shortcuts

jk/↓↑
Move down or up through a list or a grid.
hl/←→
Move across a row or between cards.
Enter
Open the focused link.
f
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.