The MG HS has 3 control parameters.
● Confirmed◆ In testing○ Supported× Not supported
Absolute throttle position TPSAE J1979Confirmed
Throttle position at idle will usually be more than 0%, and throttle position at wide open throttle will usually be less than 100%.
Pelican can show this parameter as the throttle position.
- Request
01 11 - Service 01
PID 11 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2025. Supported for 2021.
Brake pedal MG_BRAKE
- Request
22 B1 20 - Service 22
DID B120 - Module
7E3 → 7EB - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 %
- Unit
- %
In testing for 2018 to 2026.
Parking brake applied MG_PARK_BRAKE
- Request
22 BA 40 - Service 22
DID BA40 - Module
7E3 → 7EB - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 1
- Unit
- Yes or no