MG HS

Battery parameters

The MG HS has 247 battery parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

HV battery is charging? MG_HVBAT_CHARGINGConfirmed

Pelican can show this parameter as the charging state.

  • Request22 B0 48
  • Service 22DID B048
  • Module7DF → 7ED
  • Every1 s
  • Testing

Example reply from a 2025 MG HS.

Bit 7 of the reply.

0b1 = 1 → 1

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2025. In testing for 2018 to 2024, 2026.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Charge current limit MG_CHG_A_LIMIT

  • Request22 B7 12
  • Service 22DID B712
  • Module7E3 → 7EB
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 6553.5 A
Unit
A

In testing for 2018 to 2026.

Charger connected MG_CHG_CONNECTED

Pelican can show this parameter as the plug state.

  • Request22 B7 1B
  • Service 22DID B71B
  • Module7E3 → 7EB
  • Every5 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

In testing for 2018 to 2026.

Control module voltage VPWRSAE J1979Confirmed

Power input to the OBD control module. VPWR is normally battery voltage, less any voltage drop in the circuit between the battery and the control module.

Pelican can show this parameter as the starter battery voltage.

  • Request01 42
  • Service 01PID 42
  • Module7E0 → 7E8
  • Every10 s

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65535 V
Unit
V

Confirmed for 2025. Supported for 2021.

High voltage battery current MG_HBAT_C

  • Request22 B0 43
  • Service 22DID B043
  • Module781 → 789
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 40 − 1000)
Range
-1000 to 638.375 mA
Unit
mA

In testing for 2018 to 2026.

High voltage battery voltage MG_HBAT_V

  • Request22 B0 42
  • Service 22DID B042
  • Module781 → 789
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 4)
Range
300 to 450 V
Unit
V

In testing for 2018 to 2026.

Highest cell voltage MG_HVBAT_CELL_V_MAX

  • Request22 B0 58
  • Service 22DID B058
  • Module7E5 → 7ED
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2018 to 2026.

Highest cell voltage MG_HVBAT_CELL_V_MAX_GEN1

  • Request22 B0 58
  • Service 22DID B058
  • Module781 → 789
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2018 to 2026.

HV battery coolant temperature MG_HVBAT_COOLANT_TEMP

  • Request22 B0 5C
  • Service 22DID B05C
  • Module7DF → 7ED
  • Every60 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 2 − 40)
Range
0 to 87.5 °C
Unit
°C

In testing for 2018 to 2026.

HV battery coolant temperature MG_HVBAT_COOLANT_TEMP_GEN1

  • Request22 B0 5C
  • Service 22DID B05C
  • Module781 → 789
  • Every60 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 2 − 40)
Range
-40 to 87.5 °C
Unit
°C

In testing for 2018 to 2026.

HV battery coolant temperature MG_HVBAT_COOLANT_TEMP_V2

  • Request22 B0 5C
  • Service 22DID B05C
  • Module7E5 → 7ED
  • Every60 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 2 − 40)
Range
-40 to 87.5 °C
Unit
°C

In testing for 2018 to 2026.

HV battery current MG_HVBAT_CURRENT

  • Request22 B0 43
  • Service 22DID B043
  • Module7DF → 7ED
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 40 − 1000)
Range
0 to 250 A
Unit
A

In testing for 2018 to 2026.

HV battery current MG_HVBAT_CURRENT_V2

  • Request22 B0 43
  • Service 22DID B043
  • Module7E5 → 7ED
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 0.025 − 1000)
Range
0 to 250 A
Unit
A

In testing for 2018 to 2026.

HV battery error code MG_HVBAT_ERR

  • Request22 B0 47
  • Service 22DID B047
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2018 to 2026.

HV battery error code MG_HVBAT_ERR_GEN1

  • Request22 B0 47
  • Service 22DID B047
  • Module781 → 789
  • Every10 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2018 to 2026.

HV battery health MG_HVBAT_SOHConfirmed

Pelican can show this parameter as the state of health.

  • Request22 B0 61
  • Service 22DID B061
  • Module7DF → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 100 %
Unit
%

Confirmed for 2025. In testing for 2018 to 2024, 2026.

HV battery health MG_HVBAT_SOH_V2

Pelican can show this parameter as the state of health.

  • Request22 B0 61
  • Service 22DID B061
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 100 %
Unit
%

In testing for 2018 to 2026.

HV battery is charging? MG_HVBAT_CHARGINGConfirmed

Pelican can show this parameter as the charging state.

  • Request22 B0 48
  • Service 22DID B048
  • Module7DF → 7ED
  • Every1 s
  • Testing

Example reply from a 2025 MG HS.

Bit 7 of the reply.

0b1 = 1 → 1

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2025. In testing for 2018 to 2024, 2026.

HV battery is charging? MG_HVBAT_CHARGING_V2

  • Request22 B0 48
  • Service 22DID B048
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2018 to 2026.

HV battery main relay B state MG_HVBAT_RELAY_B

  • Request22 B0 49
  • Service 22DID B049
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2018 to 2026.

HV battery main relay B state MG_HVBAT_RELAY_B_GEN1

  • Request22 B0 49
  • Service 22DID B049
  • Module781 → 789
  • Every10 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2018 to 2026.

HV battery main relay G state MG_HVBAT_RELAY_G

  • Request22 B0 4A
  • Service 22DID B04A
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2018 to 2026.

HV battery main relay G state MG_HVBAT_RELAY_G_GEN1

  • Request22 B0 4A
  • Service 22DID B04A
  • Module781 → 789
  • Every10 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2018 to 2026.

HV battery main relay P state MG_HVBAT_RELAY_P

  • Request22 B0 52
  • Service 22DID B052
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2018 to 2026.

HV battery main relay P state MG_HVBAT_RELAY_P_GEN1

  • Request22 B0 52
  • Service 22DID B052
  • Module781 → 789
  • Every10 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2018 to 2026.

HV battery range count MG_HVBAT_RANGE_RAW

  • Request22 B0 CE
  • Service 22DID B0CE
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2018 to 2026.

HV battery range count MG_HVBAT_RANGE_RAW_GEN1

  • Request22 B0 CE
  • Service 22DID B0CE
  • Module781 → 789
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2018 to 2026.

HV battery temperature MG_HVBAT_TEMPConfirmed

  • Request22 B0 56
  • Service 22DID B056
  • Module7DF → 7ED
  • Every60 s
  • Testing

Example reply from a 2025 MG HS.

Bits 0 to 7 of the reply, 8 bits.

0x97 = 151 → (151 ÷ 2 − 40) = 35.5 °C

Formula
(val ÷ 2 − 40)
Range
0 to 87.5 °C
Unit
°C

Confirmed for 2025. In testing for 2018 to 2024, 2026.

HV battery temperature MG_HVBAT_TEMP_GEN1

  • Request22 B0 56
  • Service 22DID B056
  • Module781 → 789
  • Every60 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 2 − 40)
Range
-40 to 87.5 °C
Unit
°C

In testing for 2018 to 2026.

HV battery temperature MG_HVBAT_TEMP_V2

  • Request22 B0 56
  • Service 22DID B056
  • Module7E5 → 7ED
  • Every60 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 2 − 40)
Range
-40 to 87.5 °C
Unit
°C

In testing for 2018 to 2026.

HV battery voltage MG_HVBAT_VOLTAGE

  • Request22 B0 42
  • Service 22DID B042
  • Module7DF → 7ED
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 4)
Range
0 to 500 V
Unit
V

In testing for 2018 to 2026.

HV battery voltage MG_HVBAT_VOLTAGE_V2

  • Request22 B0 42
  • Service 22DID B042
  • Module7E5 → 7ED
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 0.25)
Range
0 to 500 V
Unit
V

In testing for 2018 to 2026.

HV battery voltage, vehicle control unit MG_HVBAT_V_VCU

  • Request22 B7 05
  • Service 22DID B705
  • Module7E3 → 7EB
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 6553.5 V
Unit
V

In testing for 2018 to 2026.

HV contactor closed MG_HV_CONTACTOR

  • Request22 B7 03
  • Service 22DID B703
  • Module7E3 → 7EB
  • Every5 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

In testing for 2018 to 2026.

Is charging MG_IS_CHARGING

Pelican can show this parameter as the charging state.

  • Request22 B0 48
  • Service 22DID B048
  • Module781 → 789
  • Every1 s
  • Testing

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

In testing for 2018 to 2026.

Is DC fast charging MG_IS_DCFC

  • Request22 B0 48
  • Service 22DID B048
  • Module781 → 789
  • Every1 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

In testing for 2018 to 2026.

Knock sensor voltage MG_KNOCK_SNS_V

  • Request22 B1 40
  • Service 22DID B140
  • Module7E0
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 5 ÷ 255)
Range
0 to 5 V
Unit
V

In testing for 2018 to 2026.

Lowest cell voltage MG_HVBAT_CELL_V_MIN

  • Request22 B0 59
  • Service 22DID B059
  • Module7E5 → 7ED
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2018 to 2026.

Lowest cell voltage MG_HVBAT_CELL_V_MIN_GEN1

  • Request22 B0 59
  • Service 22DID B059
  • Module781 → 789
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2018 to 2026.

State of charge MG_SOC

Pelican can show this parameter as the state of charge.

  • Request22 B0 46
  • Service 22DID B046
  • Module781 → 789
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 100 %
Unit
%

In testing for 2018 to 2026.

State of health MG_SOH

Pelican can show this parameter as the state of health.

  • Request22 B0 61
  • Service 22DID B061
  • Module781 → 789
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 100 %
Unit
%

In testing for 2018 to 2026.

Battery › EVCC

Charging MG_EVCC_CHARGING

  • Request22 B0 0F
  • Service 22DID B00F
  • Module7DF → 7EC
  • Every4 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2018 to 2026.

Charging MG_EVCC_CHARGING_V2

  • Request22 B0 0F
  • Service 22DID B00F
  • Module7E4 → 7EC
  • Every4 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2018 to 2026.

Current MG_EVCC_CURRENT

  • Request22 B0 01
  • Service 22DID B001
  • Module7DF → 7EC
  • Every180 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 5 − 409.6)
Range
0 to 250 A
Unit
A

In testing for 2018 to 2026.

Current MG_EVCC_CURRENT_V2

  • Request22 B0 01
  • Service 22DID B001
  • Module7E4 → 7EC
  • Every180 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 0.2 − 409.6)
Range
0 to 250 A
Unit
A

In testing for 2018 to 2026.

Max current MG_EVCC_MAX_CURRENT

  • Request22 B0 03
  • Service 22DID B003
  • Module7DF → 7EC
  • Every180 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 0.434782609)
Range
0 to 110.869565 A
Unit
A

In testing for 2018 to 2026.

Max Current MG_EVCC_MAX_CURRENT_V2

  • Request22 B0 03
  • Service 22DID B003
  • Module7E4 → 7EC
  • Every180 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 0.434782609)
Range
0 to 110.869565 A
Unit
A

In testing for 2018 to 2026.

Voltage MG_EVCC_VOLTAGE

  • Request22 B0 10
  • Service 22DID B010
  • Module7DF → 7EC
  • Every4 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 97)
Range
0 to 675.618556 V
Unit
V

In testing for 2018 to 2026.

Voltage MG_EVCC_VOLTAGE_V2

  • Request22 B0 10
  • Service 22DID B010
  • Module7E4 → 7EC
  • Every4 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 0.0103092783)
Range
0 to 675.618553 V
Unit
V

In testing for 2018 to 2026.

Battery › Internal

BMS Status MG_BMS_STATUSConfirmed

  • Request22 B0 48
  • Service 22DID B048
  • Module7DF → 7ED
  • Every1 s
  • Testing

Example reply from a 2025 MG HS.

Bits 0 to 7 of the reply, 8 bits.

0x97 = 151 → 151

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2025. In testing for 2018 to 2024, 2026.

HV battery bus voltage MG_HVBAT_BUS_VOLTAGE

  • Request22 B0 41
  • Service 22DID B041
  • Module7DF → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 4)
Range
0 to 1000 V
Unit
V

In testing for 2018 to 2026.

HV battery bus voltage MG_HVBAT_BUS_VOLTAGE_GEN1

  • Request22 B0 41
  • Service 22DID B041
  • Module781 → 789
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 4)
Range
0 to 1000 V
Unit
V

In testing for 2018 to 2026.

HV battery bus voltage MG_HVBAT_BUS_VOLTAGE_V2

  • Request22 B0 41
  • Service 22DID B041
  • Module7E5 → 7ED
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 4)
Range
0 to 1000 V
Unit
V

In testing for 2018 to 2026.

HV battery internal resistance MG_HVBAT_RESISTANCE

  • Request22 B0 45
  • Service 22DID B045
  • Module7DF → 7ED
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 2)
Range
0 to 32767.5
Unit
Number

In testing for 2018 to 2026.

HV battery internal resistance MG_HVBAT_RESISTANCE_V2

  • Request22 B0 45
  • Service 22DID B045
  • Module7E5 → 7ED
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 0.5)
Range
0 to 32767.5
Unit
Number

In testing for 2018 to 2026.

HV battery raw charge MG_HVBAT_RAW_SOC

HV battery raw charge

  • Request22 B0 46
  • Service 22DID B046
  • Module7DF → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 100 %
Unit
%

In testing for 2018 to 2026.

Battery › Modules › 01

HV battery module 01 max temperature MG_HVBAT_CMU01_MAXTEMP

  • Request22 B0 01
  • Service 22DID B001
  • Module7DF → 7EC
  • Every180 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
(val ÷ 2 − 40)
Range
0 to 87.5 °C
Unit
°C

In testing for 2018 to 2026.

HV battery module 01 max temperature MG_HVBAT_CMU01_MAXTEMP_V2

  • Request22 B0 01
  • Service 22DID B001
  • Module7E5 → 7ED
  • Every180 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
(val × 0.5 − 40)
Range
0 to 150 °C
Unit
°C

In testing for 2018 to 2026.

HV battery module 01 max voltage MG_HVBAT_CMU01_MAXVOLT

  • Request22 B0 01
  • Service 22DID B001
  • Module7DF → 7EC
  • Every180 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
(val ÷ 2000 + 1)
Range
0 to 10 V
Unit
V

In testing for 2018 to 2026.

HV battery module 01 max voltage MG_HVBAT_CMU01_MAXVOLT_V2

  • Request22 B0 01
  • Service 22DID B001
  • Module7E5 → 7ED
  • Every180 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
(val × 0.0005 + 1)
Range
0 to 10 V
Unit
V

In testing for 2018 to 2026.

HV battery module 01 min temperature MG_HVBAT_CMU01_MINTEMP

  • Request22 B0 01
  • Service 22DID B001
  • Module7DF → 7EC
  • Every180 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
(val ÷ 2 − 40)
Range
0 to 87.5 °C
Unit
°C

In testing for 2018 to 2026.

HV battery module 01 min temperature MG_HVBAT_CMU01_MINTEMP_V2

  • Request22 B0 01
  • Service 22DID B001
  • Module7E5 → 7ED
  • Every180 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
(val × 0.5 − 40)
Range
0 to 150 °C
Unit
°C

In testing for 2018 to 2026.

HV battery module 01 min voltage MG_HVBAT_CMU01_MINVOLT

  • Request22 B0 01
  • Service 22DID B001
  • Module7DF → 7EC
  • Every180 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 2000 + 1)
Range
0 to 10 V
Unit
V

In testing for 2018 to 2026.

HV battery module 01 min voltage MG_HVBAT_CMU01_MINVOLT_V2

  • Request22 B0 01
  • Service 22DID B001
  • Module7E5 → 7ED
  • Every180 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 0.0005 + 1)
Range
0 to 10 V
Unit
V

In testing for 2018 to 2026.

Battery › Modules › 02

HV battery module 02 max temperature MG_HVBAT_CMU02_MAXTEMP

  • Request22 B0 09
  • Service 22DID B009
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
(val ÷ 2 − 40)
Range
0 to 87.5 °C
Unit
°C

In testing for 2018 to 2026.

HV battery module 02 max temperature MG_HVBAT_CMU02_MAXTEMP_V2

  • Request22 B0 09
  • Service 22DID B009
  • Module7E5 → 7ED
  • Every180 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
(val × 0.5 − 40)
Range
0 to 150 °C
Unit
°C

In testing for 2018 to 2026.

HV battery module 02 max voltage MG_HVBAT_CMU02_MAXVOLT

  • Request22 B0 09
  • Service 22DID B009
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
(val ÷ 2000 + 1)
Range
0 to 10 V
Unit
V

In testing for 2018 to 2026.

HV battery module 02 max voltage MG_HVBAT_CMU02_MAXVOLT_V2

  • Request22 B0 09
  • Service 22DID B009
  • Module7E5 → 7ED
  • Every180 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
(val × 0.0005 + 1)
Range
0 to 10 V
Unit
V

In testing for 2018 to 2026.

HV battery module 02 min temperature MG_HVBAT_CMU02_MINTEMP

  • Request22 B0 09
  • Service 22DID B009
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
(val ÷ 2 − 40)
Range
0 to 87.5 °C
Unit
°C

In testing for 2018 to 2026.

HV battery module 02 min temperature MG_HVBAT_CMU02_MINTEMP_V2

  • Request22 B0 09
  • Service 22DID B009
  • Module7E5 → 7ED
  • Every180 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
(val × 0.5 − 40)
Range
0 to 150 °C
Unit
°C

In testing for 2018 to 2026.

HV battery module 02 min voltage MG_HVBAT_CMU02_MINVOLT

  • Request22 B0 09
  • Service 22DID B009
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 2000 + 1)
Range
0 to 10 V
Unit
V

In testing for 2018 to 2026.

HV battery module 02 min voltage MG_HVBAT_CMU02_MINVOLT_V2

  • Request22 B0 09
  • Service 22DID B009
  • Module7E5 → 7ED
  • Every180 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 0.0005 + 1)
Range
0 to 10 V
Unit
V

In testing for 2018 to 2026.

Battery › Modules › 03

HV battery module 03 max temperature MG_HVBAT_CMU03_MAXTEMP

  • Request22 B0 11
  • Service 22DID B011
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
(val ÷ 2 − 40)
Range
0 to 87.5 °C
Unit
°C

In testing for 2018 to 2026.

HV battery module 03 max temperature MG_HVBAT_CMU03_MAXTEMP_V2

  • Request22 B0 11
  • Service 22DID B011
  • Module7E5 → 7ED
  • Every180 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
(val × 0.5 − 40)
Range
0 to 150 °C
Unit
°C

In testing for 2018 to 2026.

HV battery module 03 max voltage MG_HVBAT_CMU03_MAXVOLT

  • Request22 B0 11
  • Service 22DID B011
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
(val ÷ 2000 + 1)
Range
0 to 10 V
Unit
V

In testing for 2018 to 2026.

HV battery module 03 max voltage MG_HVBAT_CMU03_MAXVOLT_V2

  • Request22 B0 11
  • Service 22DID B011
  • Module7E5 → 7ED
  • Every180 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
(val × 0.0005 + 1)
Range
0 to 10 V
Unit
V

In testing for 2018 to 2026.

HV battery module 03 min temperature MG_HVBAT_CMU03_MINTEMP

  • Request22 B0 11
  • Service 22DID B011
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
(val ÷ 2 − 40)
Range
0 to 87.5 °C
Unit
°C

In testing for 2018 to 2026.

HV battery module 03 min temperature MG_HVBAT_CMU03_MINTEMP_V2

  • Request22 B0 11
  • Service 22DID B011
  • Module7E5 → 7ED
  • Every180 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
(val × 0.5 − 40)
Range
0 to 150 °C
Unit
°C

In testing for 2018 to 2026.

HV battery module 03 min voltage MG_HVBAT_CMU03_MINVOLTConfirmed

  • Request22 B0 11
  • Service 22DID B011
  • Module7DF → 7ED
  • Every180 s
  • Testing

Example reply from a 2025 MG HS.

Bits 0 to 15 of the reply, 16 bits.

0x0758 = 1880 → (1880 ÷ 2000 + 1) = 1.94 V

Formula
(val ÷ 2000 + 1)
Range
0 to 10 V
Unit
V

Confirmed for 2025. In testing for 2018 to 2024, 2026.

HV battery module 03 min voltage MG_HVBAT_CMU03_MINVOLT_V2

  • Request22 B0 11
  • Service 22DID B011
  • Module7E5 → 7ED
  • Every180 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 0.0005 + 1)
Range
0 to 10 V
Unit
V

In testing for 2018 to 2026.

Battery › Modules › 04

HV battery module 04 max temperature MG_HVBAT_CMU04_MAXTEMP

  • Request22 B0 19
  • Service 22DID B019
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
(val ÷ 2 − 40)
Range
0 to 87.5 °C
Unit
°C

In testing for 2018 to 2026.

HV battery module 04 max temperature MG_HVBAT_CMU04_MAXTEMP_V2

  • Request22 B0 19
  • Service 22DID B019
  • Module7E5 → 7ED
  • Every180 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
(val × 0.5 − 40)
Range
0 to 150 °C
Unit
°C

In testing for 2018 to 2026.

HV battery module 04 max voltage MG_HVBAT_CMU04_MAXVOLT

  • Request22 B0 19
  • Service 22DID B019
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
(val ÷ 2000 + 1)
Range
0 to 10 V
Unit
V

In testing for 2018 to 2026.

HV battery module 04 max voltage MG_HVBAT_CMU04_MAXVOLT_V2

  • Request22 B0 19
  • Service 22DID B019
  • Module7E5 → 7ED
  • Every180 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
(val × 0.0005 + 1)
Range
0 to 10 V
Unit
V

In testing for 2018 to 2026.

HV battery module 04 min temperature MG_HVBAT_CMU04_MINTEMP

  • Request22 B0 19
  • Service 22DID B019
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
(val ÷ 2 − 40)
Range
0 to 87.5 °C
Unit
°C

In testing for 2018 to 2026.

HV battery module 04 min temperature MG_HVBAT_CMU04_MINTEMP_V2

  • Request22 B0 19
  • Service 22DID B019
  • Module7E5 → 7ED
  • Every180 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
(val × 0.5 − 40)
Range
0 to 150 °C
Unit
°C

In testing for 2018 to 2026.

HV battery module 04 min voltage MG_HVBAT_CMU04_MINVOLT

  • Request22 B0 19
  • Service 22DID B019
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 2000 + 1)
Range
0 to 10 V
Unit
V

In testing for 2018 to 2026.

HV battery module 04 min voltage MG_HVBAT_CMU04_MINVOLT_V2

  • Request22 B0 19
  • Service 22DID B019
  • Module7E5 → 7ED
  • Every180 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 0.0005 + 1)
Range
0 to 10 V
Unit
V

In testing for 2018 to 2026.

Battery › Modules › 05

HV battery module 05 max temperature MG_HVBAT_CMU05_MAXTEMP

  • Request22 B0 21
  • Service 22DID B021
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
(val ÷ 2 − 40)
Range
0 to 87.5 °C
Unit
°C

In testing for 2018 to 2026.

HV battery module 05 max temperature MG_HVBAT_CMU05_MAXTEMP_V2

  • Request22 B0 21
  • Service 22DID B021
  • Module7E5 → 7ED
  • Every180 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
(val × 0.5 − 40)
Range
0 to 150 °C
Unit
°C

In testing for 2018 to 2026.

HV battery module 05 max voltage MG_HVBAT_CMU05_MAXVOLT

  • Request22 B0 21
  • Service 22DID B021
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
(val ÷ 2000 + 1)
Range
0 to 10 V
Unit
V

In testing for 2018 to 2026.

HV battery module 05 max voltage MG_HVBAT_CMU05_MAXVOLT_V2

  • Request22 B0 21
  • Service 22DID B021
  • Module7E5 → 7ED
  • Every180 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
(val × 0.0005 + 1)
Range
0 to 10 V
Unit
V

In testing for 2018 to 2026.

HV battery module 05 min temperature MG_HVBAT_CMU05_MINTEMP

  • Request22 B0 21
  • Service 22DID B021
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
(val ÷ 2 − 40)
Range
0 to 87.5 °C
Unit
°C

In testing for 2018 to 2026.

HV battery module 05 min temperature MG_HVBAT_CMU05_MINTEMP_V2

  • Request22 B0 21
  • Service 22DID B021
  • Module7E5 → 7ED
  • Every180 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
(val × 0.5 − 40)
Range
0 to 150 °C
Unit
°C

In testing for 2018 to 2026.

HV battery module 05 min voltage MG_HVBAT_CMU05_MINVOLT

  • Request22 B0 21
  • Service 22DID B021
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 2000 + 1)
Range
0 to 10 V
Unit
V

In testing for 2018 to 2026.

HV battery module 05 min voltage MG_HVBAT_CMU05_MINVOLT_V2

  • Request22 B0 21
  • Service 22DID B021
  • Module7E5 → 7ED
  • Every180 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 0.0005 + 1)
Range
0 to 10 V
Unit
V

In testing for 2018 to 2026.

Battery › Modules › 06

HV battery module 06 max temperature MG_HVBAT_CMU06_MAXTEMP

  • Request22 B0 29
  • Service 22DID B029
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
(val ÷ 2 − 40)
Range
0 to 87.5 °C
Unit
°C

In testing for 2018 to 2026.

HV battery module 06 max temperature MG_HVBAT_CMU06_MAXTEMP_V2

  • Request22 B0 29
  • Service 22DID B029
  • Module7E5 → 7ED
  • Every180 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
(val × 0.5 − 40)
Range
0 to 150 °C
Unit
°C

In testing for 2018 to 2026.

HV battery module 06 max voltage MG_HVBAT_CMU06_MAXVOLT

  • Request22 B0 29
  • Service 22DID B029
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
(val ÷ 2000 + 1)
Range
0 to 10 V
Unit
V

In testing for 2018 to 2026.

HV battery module 06 max voltage MG_HVBAT_CMU06_MAXVOLT_V2

  • Request22 B0 29
  • Service 22DID B029
  • Module7E5 → 7ED
  • Every180 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
(val × 0.0005 + 1)
Range
0 to 10 V
Unit
V

In testing for 2018 to 2026.

HV battery module 06 min temperature MG_HVBAT_CMU06_MINTEMP

  • Request22 B0 29
  • Service 22DID B029
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
(val ÷ 2 − 40)
Range
0 to 87.5 °C
Unit
°C

In testing for 2018 to 2026.

HV battery module 06 min temperature MG_HVBAT_CMU06_MINTEMP_V2

  • Request22 B0 29
  • Service 22DID B029
  • Module7E5 → 7ED
  • Every180 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
(val × 0.5 − 40)
Range
0 to 150 °C
Unit
°C

In testing for 2018 to 2026.

HV battery module 06 min voltage MG_HVBAT_CMU06_MINVOLT

  • Request22 B0 29
  • Service 22DID B029
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 2000 + 1)
Range
0 to 10 V
Unit
V

In testing for 2018 to 2026.

HV battery module 06 min voltage MG_HVBAT_CMU06_MINVOLT_V2

  • Request22 B0 29
  • Service 22DID B029
  • Module7E5 → 7ED
  • Every180 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 0.0005 + 1)
Range
0 to 10 V
Unit
V

In testing for 2018 to 2026.

Battery › Modules › 07

HV battery module 07 max temperature MG_HVBAT_CMU07_MAXTEMP

  • Request22 B0 A3
  • Service 22DID B0A3
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
(val ÷ 2 − 40)
Range
0 to 87.5 °C
Unit
°C

In testing for 2018 to 2024, 2026. Not supported for 2025.

HV battery module 07 max temperature MG_HVBAT_CMU07_MAXTEMP_V2

  • Request22 B0 A3
  • Service 22DID B0A3
  • Module7E5 → 7ED
  • Every180 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
(val × 0.5 − 40)
Range
0 to 150 °C
Unit
°C

In testing for 2018 to 2026.

HV battery module 07 max voltage MG_HVBAT_CMU07_MAXVOLT

  • Request22 B0 A3
  • Service 22DID B0A3
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
(val ÷ 2000 + 1)
Range
0 to 10 V
Unit
V

In testing for 2018 to 2024, 2026. Not supported for 2025.

HV battery module 07 max voltage MG_HVBAT_CMU07_MAXVOLT_V2

  • Request22 B0 A3
  • Service 22DID B0A3
  • Module7E5 → 7ED
  • Every180 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
(val × 0.0005 + 1)
Range
0 to 10 V
Unit
V

In testing for 2018 to 2026.

HV battery module 07 min temperature MG_HVBAT_CMU07_MINTEMP

  • Request22 B0 A3
  • Service 22DID B0A3
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
(val ÷ 2 − 40)
Range
0 to 87.5 °C
Unit
°C

In testing for 2018 to 2024, 2026. Not supported for 2025.

HV battery module 07 min temperature MG_HVBAT_CMU07_MINTEMP_V2

  • Request22 B0 A3
  • Service 22DID B0A3
  • Module7E5 → 7ED
  • Every180 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
(val × 0.5 − 40)
Range
0 to 150 °C
Unit
°C

In testing for 2018 to 2026.

HV battery module 07 min voltage MG_HVBAT_CMU07_MINVOLT

  • Request22 B0 A3
  • Service 22DID B0A3
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 2000 + 1)
Range
0 to 10 V
Unit
V

In testing for 2018 to 2024, 2026. Not supported for 2025.

HV battery module 07 min voltage MG_HVBAT_CMU07_MINVOLT_V2

  • Request22 B0 A3
  • Service 22DID B0A3
  • Module7E5 → 7ED
  • Every180 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 0.0005 + 1)
Range
0 to 10 V
Unit
V

In testing for 2018 to 2026.

Battery › Modules › 08

HV battery module 08 max temperature MG_HVBAT_CMU08_MAXTEMP

  • Request22 B0 AB
  • Service 22DID B0AB
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
(val ÷ 2 − 40)
Range
0 to 87.5 °C
Unit
°C

In testing for 2018 to 2024, 2026. Not supported for 2025.

HV battery module 08 max temperature MG_HVBAT_CMU08_MAXTEMP_V2

  • Request22 B0 AB
  • Service 22DID B0AB
  • Module7E5 → 7ED
  • Every180 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
(val × 0.5 − 40)
Range
0 to 150 °C
Unit
°C

In testing for 2018 to 2026.

HV battery module 08 max voltage MG_HVBAT_CMU08_MAXVOLT

  • Request22 B0 AB
  • Service 22DID B0AB
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
(val ÷ 2000 + 1)
Range
0 to 10 V
Unit
V

In testing for 2018 to 2024, 2026. Not supported for 2025.

HV battery module 08 max voltage MG_HVBAT_CMU08_MAXVOLT_V2

  • Request22 B0 AB
  • Service 22DID B0AB
  • Module7E5 → 7ED
  • Every180 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
(val × 0.0005 + 1)
Range
0 to 10 V
Unit
V

In testing for 2018 to 2026.

HV battery module 08 min temperature MG_HVBAT_CMU08_MINTEMP

  • Request22 B0 AB
  • Service 22DID B0AB
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
(val ÷ 2 − 40)
Range
0 to 87.5 °C
Unit
°C

In testing for 2018 to 2024, 2026. Not supported for 2025.

HV battery module 08 min temperature MG_HVBAT_CMU08_MINTEMP_V2

  • Request22 B0 AB
  • Service 22DID B0AB
  • Module7E5 → 7ED
  • Every180 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
(val × 0.5 − 40)
Range
0 to 150 °C
Unit
°C

In testing for 2018 to 2026.

HV battery module 08 min voltage MG_HVBAT_CMU08_MINVOLT

  • Request22 B0 AB
  • Service 22DID B0AB
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 2000 + 1)
Range
0 to 10 V
Unit
V

In testing for 2018 to 2024, 2026. Not supported for 2025.

HV battery module 08 min voltage MG_HVBAT_CMU08_MINVOLT_V2

  • Request22 B0 AB
  • Service 22DID B0AB
  • Module7E5 → 7ED
  • Every180 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 0.0005 + 1)
Range
0 to 10 V
Unit
V

In testing for 2018 to 2026.

Battery › Modules › 09

HV battery module 09 max temperature MG_HVBAT_CMU09_MAXTEMP

  • Request22 B0 B3
  • Service 22DID B0B3
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
(val ÷ 2 − 40)
Range
0 to 87.5 °C
Unit
°C

In testing for 2018 to 2024, 2026. Not supported for 2025.

HV battery module 09 max temperature MG_HVBAT_CMU09_MAXTEMP_V2

  • Request22 B0 B3
  • Service 22DID B0B3
  • Module7E5 → 7ED
  • Every180 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
(val × 0.5 − 40)
Range
0 to 150 °C
Unit
°C

In testing for 2018 to 2026.

HV battery module 09 max voltage MG_HVBAT_CMU09_MAXVOLT

  • Request22 B0 B3
  • Service 22DID B0B3
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
(val ÷ 2000 + 1)
Range
0 to 10 V
Unit
V

In testing for 2018 to 2024, 2026. Not supported for 2025.

HV battery module 09 max voltage MG_HVBAT_CMU09_MAXVOLT_V2

  • Request22 B0 B3
  • Service 22DID B0B3
  • Module7E5 → 7ED
  • Every180 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
(val × 0.0005 + 1)
Range
0 to 10 V
Unit
V

In testing for 2018 to 2026.

HV battery module 09 min temperature MG_HVBAT_CMU09_MINTEMP

  • Request22 B0 B3
  • Service 22DID B0B3
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
(val ÷ 2 − 40)
Range
0 to 87.5 °C
Unit
°C

In testing for 2018 to 2024, 2026. Not supported for 2025.

HV battery module 09 min temperature MG_HVBAT_CMU09_MINTEMP_V2

  • Request22 B0 B3
  • Service 22DID B0B3
  • Module7E5 → 7ED
  • Every180 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
(val × 0.5 − 40)
Range
0 to 150 °C
Unit
°C

In testing for 2018 to 2026.

HV battery module 09 min voltage MG_HVBAT_CMU09_MINVOLT

  • Request22 B0 B3
  • Service 22DID B0B3
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 2000 + 1)
Range
0 to 10 V
Unit
V

In testing for 2018 to 2024, 2026. Not supported for 2025.

HV battery module 09 min voltage MG_HVBAT_CMU09_MINVOLT_V2

  • Request22 B0 B3
  • Service 22DID B0B3
  • Module7E5 → 7ED
  • Every180 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 0.0005 + 1)
Range
0 to 10 V
Unit
V

In testing for 2018 to 2026.

Battery › Modules › 10

HV battery module 10 max temperature MG_HVBAT_CMU10_MAXTEMP

  • Request22 B0 BB
  • Service 22DID B0BB
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
(val ÷ 2 − 40)
Range
0 to 87.5 °C
Unit
°C

In testing for 2018 to 2024, 2026. Not supported for 2025.

HV battery module 10 max temperature MG_HVBAT_CMU10_MAXTEMP_V2

  • Request22 B0 BB
  • Service 22DID B0BB
  • Module7E5 → 7ED
  • Every180 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
(val × 0.5 − 40)
Range
0 to 150 °C
Unit
°C

In testing for 2018 to 2026.

HV battery module 10 max voltage MG_HVBAT_CMU10_MAXVOLT

  • Request22 B0 BB
  • Service 22DID B0BB
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
(val ÷ 2000 + 1)
Range
0 to 10 V
Unit
V

In testing for 2018 to 2024, 2026. Not supported for 2025.

HV battery module 10 max voltage MG_HVBAT_CMU10_MAXVOLT_V2

  • Request22 B0 BB
  • Service 22DID B0BB
  • Module7E5 → 7ED
  • Every180 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
(val × 0.0005 + 1)
Range
0 to 10 V
Unit
V

In testing for 2018 to 2026.

HV battery module 10 min temperature MG_HVBAT_CMU10_MINTEMP

  • Request22 B0 BB
  • Service 22DID B0BB
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
(val ÷ 2 − 40)
Range
0 to 87.5 °C
Unit
°C

In testing for 2018 to 2024, 2026. Not supported for 2025.

HV battery module 10 min temperature MG_HVBAT_CMU10_MINTEMP_V2

  • Request22 B0 BB
  • Service 22DID B0BB
  • Module7E5 → 7ED
  • Every180 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
(val × 0.5 − 40)
Range
0 to 150 °C
Unit
°C

In testing for 2018 to 2026.

HV battery module 10 min voltage MG_HVBAT_CMU10_MINVOLT

  • Request22 B0 BB
  • Service 22DID B0BB
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 2000 + 1)
Range
0 to 10 V
Unit
V

In testing for 2018 to 2024, 2026. Not supported for 2025.

HV battery module 10 min voltage MG_HVBAT_CMU10_MINVOLT_V2

  • Request22 B0 BB
  • Service 22DID B0BB
  • Module7E5 → 7ED
  • Every180 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 0.0005 + 1)
Range
0 to 10 V
Unit
V

In testing for 2018 to 2026.

Battery › Modules › 11

HV battery module 11 max temperature MG_HVBAT_CMU11_MAXTEMP

  • Request22 B0 C3
  • Service 22DID B0C3
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
(val ÷ 2 − 40)
Range
0 to 87.5 °C
Unit
°C

In testing for 2018 to 2024, 2026. Not supported for 2025.

HV battery module 11 max temperature MG_HVBAT_CMU11_MAXTEMP_V2

  • Request22 B0 C3
  • Service 22DID B0C3
  • Module7E5 → 7ED
  • Every180 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
(val × 0.5 − 40)
Range
0 to 150 °C
Unit
°C

In testing for 2018 to 2026.

HV battery module 11 max voltage MG_HVBAT_CMU11_MAXVOLT

  • Request22 B0 C3
  • Service 22DID B0C3
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
(val ÷ 2000 + 1)
Range
0 to 10 V
Unit
V

In testing for 2018 to 2024, 2026. Not supported for 2025.

HV battery module 11 max voltage MG_HVBAT_CMU11_MAXVOLT_V2

  • Request22 B0 C3
  • Service 22DID B0C3
  • Module7E5 → 7ED
  • Every180 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
(val × 0.0005 + 1)
Range
0 to 10 V
Unit
V

In testing for 2018 to 2026.

HV battery module 11 min temperature MG_HVBAT_CMU11_MINTEMP

  • Request22 B0 C3
  • Service 22DID B0C3
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
(val ÷ 2 − 40)
Range
0 to 87.5 °C
Unit
°C

In testing for 2018 to 2024, 2026. Not supported for 2025.

HV battery module 11 min temperature MG_HVBAT_CMU11_MINTEMP_V2

  • Request22 B0 C3
  • Service 22DID B0C3
  • Module7E5 → 7ED
  • Every180 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
(val × 0.5 − 40)
Range
0 to 150 °C
Unit
°C

In testing for 2018 to 2026.

HV battery module 11 min voltage MG_HVBAT_CMU11_MINVOLT

  • Request22 B0 C3
  • Service 22DID B0C3
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 2000 + 1)
Range
0 to 10 V
Unit
V

In testing for 2018 to 2024, 2026. Not supported for 2025.

HV battery module 11 min voltage MG_HVBAT_CMU11_MINVOLT_V2

  • Request22 B0 C3
  • Service 22DID B0C3
  • Module7E5 → 7ED
  • Every180 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 0.0005 + 1)
Range
0 to 10 V
Unit
V

In testing for 2018 to 2026.

Battery › Modules › 12

HV battery module 12 max temperature MG_HVBAT_CMU12_MAXTEMP

  • Request22 B0 CB
  • Service 22DID B0CB
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
(val ÷ 2 − 40)
Range
0 to 87.5 °C
Unit
°C

In testing for 2018 to 2024, 2026. Not supported for 2025.

HV battery module 12 max temperature MG_HVBAT_CMU12_MAXTEMP_V2

  • Request22 B0 CB
  • Service 22DID B0CB
  • Module7E5 → 7ED
  • Every180 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
(val × 0.5 − 40)
Range
0 to 150 °C
Unit
°C

In testing for 2018 to 2026.

HV battery module 12 max voltage MG_HVBAT_CMU12_MAXVOLT

  • Request22 B0 CB
  • Service 22DID B0CB
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
(val ÷ 2000 + 1)
Range
0 to 10 V
Unit
V

In testing for 2018 to 2024, 2026. Not supported for 2025.

HV battery module 12 max voltage MG_HVBAT_CMU12_MAXVOLT_V2

  • Request22 B0 CB
  • Service 22DID B0CB
  • Module7E5 → 7ED
  • Every180 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
(val × 0.0005 + 1)
Range
0 to 10 V
Unit
V

In testing for 2018 to 2026.

HV battery module 12 min temperature MG_HVBAT_CMU12_MINTEMP

  • Request22 B0 CB
  • Service 22DID B0CB
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
(val ÷ 2 − 40)
Range
0 to 87.5 °C
Unit
°C

In testing for 2018 to 2024, 2026. Not supported for 2025.

HV battery module 12 min temperature MG_HVBAT_CMU12_MINTEMP_V2

  • Request22 B0 CB
  • Service 22DID B0CB
  • Module7E5 → 7ED
  • Every180 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
(val × 0.5 − 40)
Range
0 to 150 °C
Unit
°C

In testing for 2018 to 2026.

HV battery module 12 min voltage MG_HVBAT_CMU12_MINVOLT

  • Request22 B0 CB
  • Service 22DID B0CB
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 2000 + 1)
Range
0 to 10 V
Unit
V

In testing for 2018 to 2024, 2026. Not supported for 2025.

HV battery module 12 min voltage MG_HVBAT_CMU12_MINVOLT_V2

  • Request22 B0 CB
  • Service 22DID B0CB
  • Module7E5 → 7ED
  • Every180 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 0.0005 + 1)
Range
0 to 10 V
Unit
V

In testing for 2018 to 2026.

Battery › Modules › 13

HV battery module 13 max temperature MG_HVBAT_CMU13_MAXTEMP

  • Request22 B0 DB
  • Service 22DID B0DB
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
(val ÷ 2 − 40)
Range
0 to 87.5 °C
Unit
°C

In testing for 2018 to 2024, 2026. Not supported for 2025.

HV battery module 13 max temperature MG_HVBAT_CMU13_MAXTEMP_V2

  • Request22 B0 DB
  • Service 22DID B0DB
  • Module7E5 → 7ED
  • Every180 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
(val × 0.5 − 40)
Range
0 to 150 °C
Unit
°C

In testing for 2018 to 2026.

HV battery module 13 max voltage MG_HVBAT_CMU13_MAXVOLT

  • Request22 B0 DB
  • Service 22DID B0DB
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
(val ÷ 2000 + 1)
Range
0 to 10 V
Unit
V

In testing for 2018 to 2024, 2026. Not supported for 2025.

HV battery module 13 max voltage MG_HVBAT_CMU13_MAXVOLT_V2

  • Request22 B0 DB
  • Service 22DID B0DB
  • Module7E5 → 7ED
  • Every180 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
(val × 0.0005 + 1)
Range
0 to 10 V
Unit
V

In testing for 2018 to 2026.

HV battery module 13 min temperature MG_HVBAT_CMU13_MINTEMP

  • Request22 B0 DB
  • Service 22DID B0DB
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
(val ÷ 2 − 40)
Range
0 to 87.5 °C
Unit
°C

In testing for 2018 to 2024, 2026. Not supported for 2025.

HV battery module 13 min temperature MG_HVBAT_CMU13_MINTEMP_V2

  • Request22 B0 DB
  • Service 22DID B0DB
  • Module7E5 → 7ED
  • Every180 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
(val × 0.5 − 40)
Range
0 to 150 °C
Unit
°C

In testing for 2018 to 2026.

HV battery module 13 min voltage MG_HVBAT_CMU13_MINVOLT

  • Request22 B0 DB
  • Service 22DID B0DB
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 2000 + 1)
Range
0 to 10 V
Unit
V

In testing for 2018 to 2024, 2026. Not supported for 2025.

HV battery module 13 min voltage MG_HVBAT_CMU13_MINVOLT_V2

  • Request22 B0 DB
  • Service 22DID B0DB
  • Module7E5 → 7ED
  • Every180 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 0.0005 + 1)
Range
0 to 10 V
Unit
V

In testing for 2018 to 2026.

Battery › Modules › 14

HV battery module 14 max temperature MG_HVBAT_CMU14_MAXTEMP

  • Request22 B0 DC
  • Service 22DID B0DC
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
(val ÷ 2 − 40)
Range
0 to 87.5 °C
Unit
°C

In testing for 2018 to 2024, 2026. Not supported for 2025.

HV battery module 14 max temperature MG_HVBAT_CMU14_MAXTEMP_V2

  • Request22 B0 DC
  • Service 22DID B0DC
  • Module7E5 → 7ED
  • Every180 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
(val × 0.5 − 40)
Range
0 to 150 °C
Unit
°C

In testing for 2018 to 2026.

HV battery module 14 max voltage MG_HVBAT_CMU14_MAXVOLT

  • Request22 B0 DC
  • Service 22DID B0DC
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
(val ÷ 2000 + 1)
Range
0 to 10 V
Unit
V

In testing for 2018 to 2024, 2026. Not supported for 2025.

HV battery module 14 max voltage MG_HVBAT_CMU14_MAXVOLT_V2

  • Request22 B0 DC
  • Service 22DID B0DC
  • Module7E5 → 7ED
  • Every180 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
(val × 0.0005 + 1)
Range
0 to 10 V
Unit
V

In testing for 2018 to 2026.

HV battery module 14 min temperature MG_HVBAT_CMU14_MINTEMP

  • Request22 B0 DC
  • Service 22DID B0DC
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
(val ÷ 2 − 40)
Range
0 to 87.5 °C
Unit
°C

In testing for 2018 to 2024, 2026. Not supported for 2025.

HV battery module 14 min temperature MG_HVBAT_CMU14_MINTEMP_V2

  • Request22 B0 DC
  • Service 22DID B0DC
  • Module7E5 → 7ED
  • Every180 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
(val × 0.5 − 40)
Range
0 to 150 °C
Unit
°C

In testing for 2018 to 2026.

HV battery module 14 min voltage MG_HVBAT_CMU14_MINVOLT

  • Request22 B0 DC
  • Service 22DID B0DC
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 2000 + 1)
Range
0 to 10 V
Unit
V

In testing for 2018 to 2024, 2026. Not supported for 2025.

HV battery module 14 min voltage MG_HVBAT_CMU14_MINVOLT_V2

  • Request22 B0 DC
  • Service 22DID B0DC
  • Module7E5 → 7ED
  • Every180 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 0.0005 + 1)
Range
0 to 10 V
Unit
V

In testing for 2018 to 2026.

Battery › Modules › 15

HV battery module 15 max temperature MG_HVBAT_CMU15_MAXTEMP

  • Request22 B0 DD
  • Service 22DID B0DD
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
(val ÷ 2 − 40)
Range
0 to 87.5 °C
Unit
°C

In testing for 2018 to 2024, 2026. Not supported for 2025.

HV battery module 15 max temperature MG_HVBAT_CMU15_MAXTEMP_V2

  • Request22 B0 DD
  • Service 22DID B0DD
  • Module7E5 → 7ED
  • Every180 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
(val × 0.5 − 40)
Range
0 to 150 °C
Unit
°C

In testing for 2018 to 2026.

HV battery module 15 max voltage MG_HVBAT_CMU15_MAXVOLT

  • Request22 B0 DD
  • Service 22DID B0DD
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
(val ÷ 2000 + 1)
Range
0 to 10 V
Unit
V

In testing for 2018 to 2024, 2026. Not supported for 2025.

HV battery module 15 max voltage MG_HVBAT_CMU15_MAXVOLT_V2

  • Request22 B0 DD
  • Service 22DID B0DD
  • Module7E5 → 7ED
  • Every180 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
(val × 0.0005 + 1)
Range
0 to 10 V
Unit
V

In testing for 2018 to 2026.

HV battery module 15 min temperature MG_HVBAT_CMU15_MINTEMP

  • Request22 B0 DD
  • Service 22DID B0DD
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
(val ÷ 2 − 40)
Range
0 to 87.5 °C
Unit
°C

In testing for 2018 to 2024, 2026. Not supported for 2025.

HV battery module 15 min temperature MG_HVBAT_CMU15_MINTEMP_V2

  • Request22 B0 DD
  • Service 22DID B0DD
  • Module7E5 → 7ED
  • Every180 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
(val × 0.5 − 40)
Range
0 to 150 °C
Unit
°C

In testing for 2018 to 2026.

HV battery module 15 min voltage MG_HVBAT_CMU15_MINVOLT

  • Request22 B0 DD
  • Service 22DID B0DD
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 2000 + 1)
Range
0 to 10 V
Unit
V

In testing for 2018 to 2024, 2026. Not supported for 2025.

HV battery module 15 min voltage MG_HVBAT_CMU15_MINVOLT_V2

  • Request22 B0 DD
  • Service 22DID B0DD
  • Module7E5 → 7ED
  • Every180 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 0.0005 + 1)
Range
0 to 10 V
Unit
V

In testing for 2018 to 2026.

Battery › Modules › 16

HV battery module 16 max temperature MG_HVBAT_CMU16_MAXTEMP

  • Request22 B0 DE
  • Service 22DID B0DE
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
(val ÷ 2 − 40)
Range
0 to 87.5 °C
Unit
°C

In testing for 2018 to 2024, 2026. Not supported for 2025.

HV battery module 16 max temperature MG_HVBAT_CMU16_MAXTEMP_V2

  • Request22 B0 DE
  • Service 22DID B0DE
  • Module7E5 → 7ED
  • Every180 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
(val × 0.5 − 40)
Range
0 to 150 °C
Unit
°C

In testing for 2018 to 2026.

HV battery module 16 max voltage MG_HVBAT_CMU16_MAXVOLT

  • Request22 B0 DE
  • Service 22DID B0DE
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
(val ÷ 2000 + 1)
Range
0 to 10 V
Unit
V

In testing for 2018 to 2024, 2026. Not supported for 2025.

HV battery module 16 max voltage MG_HVBAT_CMU16_MAXVOLT_V2

  • Request22 B0 DE
  • Service 22DID B0DE
  • Module7E5 → 7ED
  • Every180 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
(val × 0.0005 + 1)
Range
0 to 10 V
Unit
V

In testing for 2018 to 2026.

HV battery module 16 min temperature MG_HVBAT_CMU16_MINTEMP

  • Request22 B0 DE
  • Service 22DID B0DE
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
(val ÷ 2 − 40)
Range
0 to 87.5 °C
Unit
°C

In testing for 2018 to 2024, 2026. Not supported for 2025.

HV battery module 16 min temperature MG_HVBAT_CMU16_MINTEMP_V2

  • Request22 B0 DE
  • Service 22DID B0DE
  • Module7E5 → 7ED
  • Every180 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
(val × 0.5 − 40)
Range
0 to 150 °C
Unit
°C

In testing for 2018 to 2026.

HV battery module 16 min voltage MG_HVBAT_CMU16_MINVOLT

  • Request22 B0 DE
  • Service 22DID B0DE
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 2000 + 1)
Range
0 to 10 V
Unit
V

In testing for 2018 to 2024, 2026. Not supported for 2025.

HV battery module 16 min voltage MG_HVBAT_CMU16_MINVOLT_V2

  • Request22 B0 DE
  • Service 22DID B0DE
  • Module7E5 → 7ED
  • Every180 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 0.0005 + 1)
Range
0 to 10 V
Unit
V

In testing for 2018 to 2026.

Battery › Modules › 17

HV battery module 17 max temperature MG_HVBAT_CMU17_MAXTEMP

  • Request22 B1 0E
  • Service 22DID B10E
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
(val ÷ 2 − 40)
Range
0 to 87.5 °C
Unit
°C

In testing for 2018 to 2024, 2026. Not supported for 2025.

HV battery module 17 max temperature MG_HVBAT_CMU17_MAXTEMP_V2

  • Request22 B1 0E
  • Service 22DID B10E
  • Module7E5 → 7ED
  • Every180 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
(val × 0.5 − 40)
Range
0 to 150 °C
Unit
°C

In testing for 2018 to 2026.

HV battery module 17 max voltage MG_HVBAT_CMU17_MAXVOLT

  • Request22 B1 0E
  • Service 22DID B10E
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
(val ÷ 2000 + 1)
Range
0 to 10 V
Unit
V

In testing for 2018 to 2024, 2026. Not supported for 2025.

HV battery module 17 max voltage MG_HVBAT_CMU17_MAXVOLT_V2

  • Request22 B1 0E
  • Service 22DID B10E
  • Module7E5 → 7ED
  • Every180 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
(val × 0.0005 + 1)
Range
0 to 10 V
Unit
V

In testing for 2018 to 2026.

HV battery module 17 min temperature MG_HVBAT_CMU17_MINTEMP

  • Request22 B1 0E
  • Service 22DID B10E
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
(val ÷ 2 − 40)
Range
0 to 87.5 °C
Unit
°C

In testing for 2018 to 2024, 2026. Not supported for 2025.

HV battery module 17 min temperature MG_HVBAT_CMU17_MINTEMP_V2

  • Request22 B1 0E
  • Service 22DID B10E
  • Module7E5 → 7ED
  • Every180 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
(val × 0.5 − 40)
Range
0 to 150 °C
Unit
°C

In testing for 2018 to 2026.

HV battery module 17 min voltage MG_HVBAT_CMU17_MINVOLT

  • Request22 B1 0E
  • Service 22DID B10E
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 2000 + 1)
Range
0 to 10 V
Unit
V

In testing for 2018 to 2024, 2026. Not supported for 2025.

HV battery module 17 min voltage MG_HVBAT_CMU17_MINVOLT_V2

  • Request22 B1 0E
  • Service 22DID B10E
  • Module7E5 → 7ED
  • Every180 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 0.0005 + 1)
Range
0 to 10 V
Unit
V

In testing for 2018 to 2026.

Battery › Modules › 18

HV battery module 18 max temperature MG_HVBAT_CMU18_MAXTEMP

  • Request22 B1 0F
  • Service 22DID B10F
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
(val ÷ 2 − 40)
Range
0 to 87.5 °C
Unit
°C

In testing for 2018 to 2024, 2026. Not supported for 2025.

HV battery module 18 max temperature MG_HVBAT_CMU18_MAXTEMP_V2

  • Request22 B1 0F
  • Service 22DID B10F
  • Module7E5 → 7ED
  • Every180 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
(val × 0.5 − 40)
Range
0 to 150 °C
Unit
°C

In testing for 2018 to 2026.

HV battery module 18 max voltage MG_HVBAT_CMU18_MAXVOLT

  • Request22 B1 0F
  • Service 22DID B10F
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
(val ÷ 2000 + 1)
Range
0 to 10 V
Unit
V

In testing for 2018 to 2024, 2026. Not supported for 2025.

HV battery module 18 max voltage MG_HVBAT_CMU18_MAXVOLT_V2

  • Request22 B1 0F
  • Service 22DID B10F
  • Module7E5 → 7ED
  • Every180 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
(val × 0.0005 + 1)
Range
0 to 10 V
Unit
V

In testing for 2018 to 2026.

HV battery module 18 min temperature MG_HVBAT_CMU18_MINTEMP

  • Request22 B1 0F
  • Service 22DID B10F
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
(val ÷ 2 − 40)
Range
0 to 87.5 °C
Unit
°C

In testing for 2018 to 2024, 2026. Not supported for 2025.

HV battery module 18 min temperature MG_HVBAT_CMU18_MINTEMP_V2

  • Request22 B1 0F
  • Service 22DID B10F
  • Module7E5 → 7ED
  • Every180 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
(val × 0.5 − 40)
Range
0 to 150 °C
Unit
°C

In testing for 2018 to 2026.

HV battery module 18 min voltage MG_HVBAT_CMU18_MINVOLT

  • Request22 B1 0F
  • Service 22DID B10F
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 2000 + 1)
Range
0 to 10 V
Unit
V

In testing for 2018 to 2024, 2026. Not supported for 2025.

HV battery module 18 min voltage MG_HVBAT_CMU18_MINVOLT_V2

  • Request22 B1 0F
  • Service 22DID B10F
  • Module7E5 → 7ED
  • Every180 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 0.0005 + 1)
Range
0 to 10 V
Unit
V

In testing for 2018 to 2026.

Battery › Modules › 19

HV battery module 19 max temperature MG_HVBAT_CMU19_MAXTEMP

  • Request22 B1 10
  • Service 22DID B110
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
(val ÷ 2 − 40)
Range
0 to 87.5 °C
Unit
°C

In testing for 2018 to 2026.

HV battery module 19 max temperature MG_HVBAT_CMU19_MAXTEMP_V2

  • Request22 B1 10
  • Service 22DID B110
  • Module7E5 → 7ED
  • Every180 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
(val × 0.5 − 40)
Range
0 to 150 °C
Unit
°C

In testing for 2018 to 2026.

HV battery module 19 max voltage MG_HVBAT_CMU19_MAXVOLT

  • Request22 B1 10
  • Service 22DID B110
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
(val ÷ 2000 + 1)
Range
0 to 10 V
Unit
V

In testing for 2018 to 2026.

HV battery module 19 max voltage MG_HVBAT_CMU19_MAXVOLT_V2

  • Request22 B1 10
  • Service 22DID B110
  • Module7E5 → 7ED
  • Every180 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
(val × 0.0005 + 1)
Range
0 to 10 V
Unit
V

In testing for 2018 to 2026.

HV battery module 19 min temperature MG_HVBAT_CMU19_MINTEMP

  • Request22 B1 10
  • Service 22DID B110
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
(val ÷ 2 − 40)
Range
0 to 87.5 °C
Unit
°C

In testing for 2018 to 2026.

HV battery module 19 min temperature MG_HVBAT_CMU19_MINTEMP_V2

  • Request22 B1 10
  • Service 22DID B110
  • Module7E5 → 7ED
  • Every180 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
(val × 0.5 − 40)
Range
0 to 150 °C
Unit
°C

In testing for 2018 to 2026.

HV battery module 19 min voltage MG_HVBAT_CMU19_MINVOLTConfirmed

  • Request22 B1 10
  • Service 22DID B110
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 2000 + 1)
Range
0 to 10 V
Unit
V

Confirmed for 2025. In testing for 2018 to 2024, 2026.

HV battery module 19 min voltage MG_HVBAT_CMU19_MINVOLT_V2

  • Request22 B1 10
  • Service 22DID B110
  • Module7E5 → 7ED
  • Every180 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 0.0005 + 1)
Range
0 to 10 V
Unit
V

In testing for 2018 to 2026.

Battery › Modules › 20

HV battery module 20 max temperature MG_HVBAT_CMU20_MAXTEMP

  • Request22 B1 11
  • Service 22DID B111
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
(val ÷ 2 − 40)
Range
0 to 87.5 °C
Unit
°C

In testing for 2018 to 2026.

HV battery module 20 max temperature MG_HVBAT_CMU20_MAXTEMP_V2

  • Request22 B1 11
  • Service 22DID B111
  • Module7E5 → 7ED
  • Every180 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
(val × 0.5 − 40)
Range
0 to 150 °C
Unit
°C

In testing for 2018 to 2026.

HV battery module 20 max voltage MG_HVBAT_CMU20_MAXVOLT

  • Request22 B1 11
  • Service 22DID B111
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
(val ÷ 2000 + 1)
Range
0 to 10 V
Unit
V

In testing for 2018 to 2026.

HV battery module 20 max voltage MG_HVBAT_CMU20_MAXVOLT_V2

  • Request22 B1 11
  • Service 22DID B111
  • Module7E5 → 7ED
  • Every180 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
(val × 0.0005 + 1)
Range
0 to 10 V
Unit
V

In testing for 2018 to 2026.

HV battery module 20 min temperature MG_HVBAT_CMU20_MINTEMP

  • Request22 B1 11
  • Service 22DID B111
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
(val ÷ 2 − 40)
Range
0 to 87.5 °C
Unit
°C

In testing for 2018 to 2026.

HV battery module 20 min temperature MG_HVBAT_CMU20_MINTEMP_V2

  • Request22 B1 11
  • Service 22DID B111
  • Module7E5 → 7ED
  • Every180 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
(val × 0.5 − 40)
Range
0 to 150 °C
Unit
°C

In testing for 2018 to 2026.

HV battery module 20 min voltage MG_HVBAT_CMU20_MINVOLTConfirmed

  • Request22 B1 11
  • Service 22DID B111
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 2000 + 1)
Range
0 to 10 V
Unit
V

Confirmed for 2025. In testing for 2018 to 2024, 2026.

HV battery module 20 min voltage MG_HVBAT_CMU20_MINVOLT_V2

  • Request22 B1 11
  • Service 22DID B111
  • Module7E5 → 7ED
  • Every180 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 0.0005 + 1)
Range
0 to 10 V
Unit
V

In testing for 2018 to 2026.

Battery › Modules › 21

HV battery module 21 max temperature MG_HVBAT_CMU21_MAXTEMP

  • Request22 B1 12
  • Service 22DID B112
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
(val ÷ 2 − 40)
Range
0 to 87.5 °C
Unit
°C

In testing for 2018 to 2026.

HV battery module 21 max temperature MG_HVBAT_CMU21_MAXTEMP_V2

  • Request22 B1 12
  • Service 22DID B112
  • Module7E5 → 7ED
  • Every180 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
(val × 0.5 − 40)
Range
0 to 150 °C
Unit
°C

In testing for 2018 to 2026.

HV battery module 21 max voltage MG_HVBAT_CMU21_MAXVOLT

  • Request22 B1 12
  • Service 22DID B112
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
(val ÷ 2000 + 1)
Range
0 to 10 V
Unit
V

In testing for 2018 to 2026.

HV battery module 21 max voltage MG_HVBAT_CMU21_MAXVOLT_V2

  • Request22 B1 12
  • Service 22DID B112
  • Module7E5 → 7ED
  • Every180 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
(val × 0.0005 + 1)
Range
0 to 10 V
Unit
V

In testing for 2018 to 2026.

HV battery module 21 min temperature MG_HVBAT_CMU21_MINTEMP

  • Request22 B1 12
  • Service 22DID B112
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
(val ÷ 2 − 40)
Range
0 to 87.5 °C
Unit
°C

In testing for 2018 to 2026.

HV battery module 21 min temperature MG_HVBAT_CMU21_MINTEMP_V2

  • Request22 B1 12
  • Service 22DID B112
  • Module7E5 → 7ED
  • Every180 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
(val × 0.5 − 40)
Range
0 to 150 °C
Unit
°C

In testing for 2018 to 2026.

HV battery module 21 min voltage MG_HVBAT_CMU21_MINVOLTConfirmed

  • Request22 B1 12
  • Service 22DID B112
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 2000 + 1)
Range
0 to 10 V
Unit
V

Confirmed for 2025. In testing for 2018 to 2024, 2026.

HV battery module 21 min voltage MG_HVBAT_CMU21_MINVOLT_V2

  • Request22 B1 12
  • Service 22DID B112
  • Module7E5 → 7ED
  • Every180 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 0.0005 + 1)
Range
0 to 10 V
Unit
V

In testing for 2018 to 2026.

Battery › Modules › 22

HV battery module 22 max temperature MG_HVBAT_CMU22_MAXTEMP

  • Request22 B1 13
  • Service 22DID B113
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
(val ÷ 2 − 40)
Range
0 to 87.5 °C
Unit
°C

In testing for 2018 to 2026.

HV battery module 22 max temperature MG_HVBAT_CMU22_MAXTEMP_V2

  • Request22 B1 13
  • Service 22DID B113
  • Module7E5 → 7ED
  • Every180 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
(val × 0.5 − 40)
Range
0 to 150 °C
Unit
°C

In testing for 2018 to 2026.

HV battery module 22 max voltage MG_HVBAT_CMU22_MAXVOLT

  • Request22 B1 13
  • Service 22DID B113
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
(val ÷ 2000 + 1)
Range
0 to 10 V
Unit
V

In testing for 2018 to 2026.

HV battery module 22 max voltage MG_HVBAT_CMU22_MAXVOLT_V2

  • Request22 B1 13
  • Service 22DID B113
  • Module7E5 → 7ED
  • Every180 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
(val × 0.0005 + 1)
Range
0 to 10 V
Unit
V

In testing for 2018 to 2026.

HV battery module 22 min temperature MG_HVBAT_CMU22_MINTEMP

  • Request22 B1 13
  • Service 22DID B113
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
(val ÷ 2 − 40)
Range
0 to 87.5 °C
Unit
°C

In testing for 2018 to 2026.

HV battery module 22 min temperature MG_HVBAT_CMU22_MINTEMP_V2

  • Request22 B1 13
  • Service 22DID B113
  • Module7E5 → 7ED
  • Every180 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
(val × 0.5 − 40)
Range
0 to 150 °C
Unit
°C

In testing for 2018 to 2026.

HV battery module 22 min voltage MG_HVBAT_CMU22_MINVOLTConfirmed

  • Request22 B1 13
  • Service 22DID B113
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 2000 + 1)
Range
0 to 10 V
Unit
V

Confirmed for 2025. In testing for 2018 to 2024, 2026.

HV battery module 22 min voltage MG_HVBAT_CMU22_MINVOLT_V2

  • Request22 B1 13
  • Service 22DID B113
  • Module7E5 → 7ED
  • Every180 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 0.0005 + 1)
Range
0 to 10 V
Unit
V

In testing for 2018 to 2026.

Battery › Modules › 23

HV battery module 23 max temperature MG_HVBAT_CMU23_MAXTEMP

  • Request22 B1 14
  • Service 22DID B114
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
(val ÷ 2 − 40)
Range
0 to 87.5 °C
Unit
°C

In testing for 2018 to 2026.

HV battery module 23 max temperature MG_HVBAT_CMU23_MAXTEMP_V2

  • Request22 B1 14
  • Service 22DID B114
  • Module7E5 → 7ED
  • Every180 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
(val × 0.5 − 40)
Range
0 to 150 °C
Unit
°C

In testing for 2018 to 2026.

HV battery module 23 max voltage MG_HVBAT_CMU23_MAXVOLT

  • Request22 B1 14
  • Service 22DID B114
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
(val ÷ 2000 + 1)
Range
0 to 10 V
Unit
V

In testing for 2018 to 2026.

HV battery module 23 max voltage MG_HVBAT_CMU23_MAXVOLT_V2

  • Request22 B1 14
  • Service 22DID B114
  • Module7E5 → 7ED
  • Every180 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
(val × 0.0005 + 1)
Range
0 to 10 V
Unit
V

In testing for 2018 to 2026.

HV battery module 23 min temperature MG_HVBAT_CMU23_MINTEMP

  • Request22 B1 14
  • Service 22DID B114
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
(val ÷ 2 − 40)
Range
0 to 87.5 °C
Unit
°C

In testing for 2018 to 2026.

HV battery module 23 min temperature MG_HVBAT_CMU23_MINTEMP_V2

  • Request22 B1 14
  • Service 22DID B114
  • Module7E5 → 7ED
  • Every180 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
(val × 0.5 − 40)
Range
0 to 150 °C
Unit
°C

In testing for 2018 to 2026.

HV battery module 23 min voltage MG_HVBAT_CMU23_MINVOLTConfirmed

  • Request22 B1 14
  • Service 22DID B114
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 2000 + 1)
Range
0 to 10 V
Unit
V

Confirmed for 2025. In testing for 2018 to 2024, 2026.

HV battery module 23 min voltage MG_HVBAT_CMU23_MINVOLT_V2

  • Request22 B1 14
  • Service 22DID B114
  • Module7E5 → 7ED
  • Every180 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 0.0005 + 1)
Range
0 to 10 V
Unit
V

In testing for 2018 to 2026.

Battery › Modules › 24

HV battery module 24 max temperature MG_HVBAT_CMU24_MAXTEMP

  • Request22 B1 15
  • Service 22DID B115
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
(val ÷ 2 − 40)
Range
0 to 87.5 °C
Unit
°C

In testing for 2018 to 2026.

HV battery module 24 max temperature MG_HVBAT_CMU24_MAXTEMP_V2

  • Request22 B1 15
  • Service 22DID B115
  • Module7E5 → 7ED
  • Every180 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
(val × 0.5 − 40)
Range
0 to 150 °C
Unit
°C

In testing for 2018 to 2026.

HV battery module 24 max voltage MG_HVBAT_CMU24_MAXVOLT

  • Request22 B1 15
  • Service 22DID B115
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
(val ÷ 2000 + 1)
Range
0 to 10 V
Unit
V

In testing for 2018 to 2026.

HV battery module 24 max voltage MG_HVBAT_CMU24_MAXVOLT_V2

  • Request22 B1 15
  • Service 22DID B115
  • Module7E5 → 7ED
  • Every180 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
(val × 0.0005 + 1)
Range
0 to 10 V
Unit
V

In testing for 2018 to 2026.

HV battery module 24 min temperature MG_HVBAT_CMU24_MINTEMP

  • Request22 B1 15
  • Service 22DID B115
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
(val ÷ 2 − 40)
Range
0 to 87.5 °C
Unit
°C

In testing for 2018 to 2026.

HV battery module 24 min temperature MG_HVBAT_CMU24_MINTEMP_V2

  • Request22 B1 15
  • Service 22DID B115
  • Module7E5 → 7ED
  • Every180 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
(val × 0.5 − 40)
Range
0 to 150 °C
Unit
°C

In testing for 2018 to 2026.

HV battery module 24 min voltage MG_HVBAT_CMU24_MINVOLTConfirmed

  • Request22 B1 15
  • Service 22DID B115
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 2000 + 1)
Range
0 to 10 V
Unit
V

Confirmed for 2025. In testing for 2018 to 2024, 2026.

HV battery module 24 min voltage MG_HVBAT_CMU24_MINVOLT_V2

  • Request22 B1 15
  • Service 22DID B115
  • Module7E5 → 7ED
  • Every180 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 0.0005 + 1)
Range
0 to 10 V
Unit
V

In testing for 2018 to 2026.

Keyboard shortcuts

jk/↓↑
Move down or up through a list or a grid.
hl/←→
Move across a row or between cards.
Enter
Open the focused link.
f
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?