Transmission parameters
The Lincoln MKX has 27 transmission parameters.
● Confirmed◆ In testing○ Supported× Not supported
All-wheel drive clutch diagnostic signal LINCOLN_AWD_CLU_DIAGNOSTIC
- Request
22 1E 62 - Service 22
DID 1E62 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2007 to 2018.
All-wheel drive clutch, commanded control signal LINCOLN_AWD_CLU_CMD_CTRL_SIG
- Request
22 1E 63 - Service 22
DID 1E63 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2007 to 2018.
Axle gear ratio, measured LINCOLN_AXLE_GEAR_RATIO_MEAS
- Request
22 1E 16 - Service 22
DID 1E16 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 10
- Unit
- Number
In testing for 2007 to 2018.
Converter speed ratio LINCOLN_CONV_SPD_RAT
- Request
22 11 BA - Service 22
DID 11BA - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 5 ÷ 82)- Range
- 0 to 3996.0365
- Unit
- Number
In testing for 2007 to 2018.
Gear LINCOLN_GEAR_7E1
- Request
22 1E 1F - Service 22
DID 1E1F - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 16)- Range
- -2048 to 2047
- Unit
- Number
In testing for 2007 to 2018.
Gear commanded LINCOLN_GEAR_CMD
- Request
22 1E 12 - Service 22
DID 1E12 - Module
7E6 → 7EE - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
0 | UNKNOWN | Unknown |
20 | L | |
40 | D | |
50 | N | |
60 | R | |
70 | P | |
255 | FAULT | Fault |
In testing for 2007 to 2018.
Gear ratio, commanded LINCOLN_PCM_CMD_TRANS_GEAR_RATIO
- Request
22 1E 19 - Service 22
DID 1E19 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 16 ÷ 65535)- Range
- 0 to 16
- Unit
- Number
In testing for 2007 to 2018.
Gear, engaged LINCOLN_GEAR_ENG
- Request
22 1E 1F - Service 22
DID 1E1F - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 6
- Unit
- Number
In testing for 2007 to 2018.
Measured current of clutch a actuator LINCOLN_MEAS_CURRENT_CLU
- Request
22 1E 9E - Service 22
DID 1E9E - Module
703 → 70B - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -327 to 327 A
- Unit
- A
In testing for 2007 to 2018.
Torque converter line pressure LINCOLN_TQ_CONV_LINE_P
- Request
22 11 C0 - Service 22
DID 11C0 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 172369 ÷ 5000)- Range
- 0 to 8790.819 kPa
- Unit
- kPa
In testing for 2007 to 2018.
Torque converter slip LINCOLN_TQ_CONV_SLIP
- Request
22 11 B8 - Service 22
DID 11B8 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1.638538424)- Range
- 0 to 39996.0104 rpm
- Unit
- rpm
In testing for 2007 to 2018.
Torque into torque converter LINCOLN_TQ_INTO_TQ_CONV
- Request
22 09 CB - Service 22
DID 09CB - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1.35581795)- Range
- 0 to 48336.1353 N·m
- Unit
- N·m
In testing for 2007 to 2018.
Torque into torque converter LINCOLN_TQ_INTO_TQ_CONV_7E0
- Request
22 16 3A - Service 22
DID 163A - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 0.2711635897)- Range
- 0 to 69.1467 N·m
- Unit
- N·m
In testing for 2007 to 2018.
Torque into torque converter, variant 2 LINCOLN_TQ_INTO_TQ_CONV_VAR_2
- Request
22 16 3A - Service 22
DID 163A - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 0.2711635897)- Range
- 0 to 69.1467 N·m
- Unit
- N·m
In testing for 2007 to 2018.
Transmission fluid fluid quality LINCOLN_TRANS_FLUID_FLUID
- Request
22 18 0F - Service 22
DID 180F - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2007 to 2018.
Transmission fluid temperature, variant 1 LINCOLN_ATF_T_VAR_1
- Request
22 16 74 - Service 22
DID 1674 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 8)- Range
- 0 to 8191 °F
- Unit
- °F
In testing for 2007 to 2018.
Transmission fluid temperature, variant 2 LINCOLN_ATF_T_VAR_2
- Request
22 16 74 - Service 22
DID 1674 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 °F
- Unit
- °F
In testing for 2007 to 2018.
Transmission fluid temperature, variant 5 LINCOLN_ATF_T_VAR_5
- Request
22 1E 3F - Service 22
DID 1E3F - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
val- Range
- -32768 to 32767 °C
- Unit
- °C
In testing for 2007 to 2018.
Transmission fluid temperature, variant 6 LINCOLN_ATF_T_VAR_6
- Request
22 09 2C - Service 22
DID 092C - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 °F
- Unit
- °F
In testing for 2007 to 2018.
Transmission gear LINCOLN_TRANS_GEAR
- Request
22 11 B3 - Service 22
DID 11B3 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 2)- Range
- 0 to 127.5
- Unit
- Number
In testing for 2007 to 2018.
Transmission gear LINCOLN_TRANS_GEAR_7E1
- Request
22 11 B3 - Service 22
DID 11B3 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 2)- Range
- 0 to 127.5
- Unit
- Number
In testing for 2007 to 2018.
Transmission gear ratio LINCOLN_TRANS_GEAR_RAT
- Request
22 16 3B - Service 22
DID 163B - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 15.7480315)- Range
- 0 to 4015.748
- Unit
- Number
In testing for 2007 to 2018.
Transmission odometer LINCOLN_TRANS_ODO
- Request
22 DD 01 - Service 22
DID DD01 - Module
7E1 → 7E9 - Every
30 s - Testing
Bits 0 to 23 of the reply, 24 bits.
- Formula
val- Range
- 0 to 16777215 °C
- Unit
- °C
In testing for 2007 to 2018.
Transmission oil temperature LINCOLN_TOT_V2
- Request
22 1E 1C - Service 22
DID 1E1C - Module
7DF - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 16)- Range
- 0 to 255 °C
- Unit
- °C
In testing for 2007 to 2018.
Transmission output shaft speed LINCOLN_TRANS_OUTPUT_SHFT
- Request
22 11 B5 - Service 22
DID 11B5 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 40)- Range
- 0 to 1638.375 rpm
- Unit
- rpm
In testing for 2007 to 2018.
Transmission pressure, commanded LINCOLN_PCM_CMD_TRANS_MAIN_LINE_P
- Request
22 1E 1A - Service 22
DID 1E1A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val × 2)- Range
- -65536 to 65534 kPa
- Unit
- kPa
In testing for 2007 to 2018.
Transmission temperature LINCOLN_TT
- Request
22 1E 1C - Service 22
DID 1E1C - Module
7E6 → 7EE - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 16)- Range
- -300 to 300 °C
- Unit
- °C
In testing for 2007 to 2012, 2014 to 2015, 2017 to 2018. Not supported for 2013, 2016.