Lexus GX

ECU parameters

The Lexus GX has 4 ECU parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

Exhaust VVT hold learn value bank 1 LEXUS_EXH_VVT_HOLD_LEARN_1Confirmed

  • Request22 10 89
  • Service 22DID 1089
  • Module700 → 708
  • Every1 s
  • Testing

Example reply from a 2024 Lexus GX.

Bits 0 to 15 of the reply, 16 bits.

0x1E7B = 7803 → (7803 × 399.9 ÷ 65535) = 47.614553 %

Formula
(val × 399.9 ÷ 65535)
Range
0 to 100 %
Unit
%

Confirmed for 2024. In testing for 2003 to 2023, 2025 to 2026.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Exhaust VVT hold learn value bank 1 LEXUS_EXH_VVT_HOLD_LEARN_1Confirmed

  • Request22 10 89
  • Service 22DID 1089
  • Module700 → 708
  • Every1 s
  • Testing

Example reply from a 2024 Lexus GX.

Bits 0 to 15 of the reply, 16 bits.

0x1E7B = 7803 → (7803 × 399.9 ÷ 65535) = 47.614553 %

Formula
(val × 399.9 ÷ 65535)
Range
0 to 100 %
Unit
%

Confirmed for 2024. In testing for 2003 to 2023, 2025 to 2026.

Inspection mode LEXUS_INSPECTION_MODE

  • Request21 A6
  • Service 21PID A6
  • Module7B0 → 7B8
  • Every30 s
  • Testing

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

VVT-ie duty ratio bank 1 LEXUS_VVT_IE_DUTY_RATIO_1

  • Request22 10 8A
  • Service 22DID 108A
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 14 of the reply, 15 bits.

Formula
(val × 399.9 ÷ 65535 − 200)
Range
-200 to -0.0531 %
Unit
%

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

VVT-ie motor direction: forward bank 1 LEXUS_VVT_IE_MOTOR_DIRECTION_FORWARD_1

  • Request22 10 8A
  • Service 22DID 108A
  • Module700 → 708
  • Every1 s
  • Testing

Bit 15 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Keyboard shortcuts

jk/↓↑
Move down or up through a list or a grid.
hl/←→
Move across a row or between cards.
Enter
Open the focused link.
f
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.