Lexus GX

Climate parameters

The Lexus GX has 32 climate parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

Ambient temperature LEXUS_AMBIENT_T_700Confirmed

  • Request22 1F 46
  • Service 22DID 1F46
  • Module700 → 708
  • Every1 s
  • Testing

Example reply from a 2024 Lexus GX.

Bits 0 to 7 of the reply, 8 bits.

0x1E = 30 → (30 − 40) = -10 °C

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2024. In testing for 2003 to 2023, 2025 to 2026.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

A/C compressor pressure LEXUS_IA_AC_P

  • Request22 03 93
  • Service 22DID 0393
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 245251 ÷ 845473)
Range
0 to 1000 psi
Unit
psi

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

A/C compressor pressure sensor voltage LEXUS_IA_AC_P_SENS_V

  • Request22 98 00
  • Service 22DID 9800
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 1024)
Range
0 to 5 V
Unit
V

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

A/C compressor, state LEXUS_IA_AC_STATE

  • Request22 09 9B
  • Service 22DID 099B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Adjusted ambient temperature LEXUS_ADJUSTED_AMBIENT_T

  • Request21 3D
  • Service 21PID 3D
  • Module7C4 → 7CC
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 81.6 ÷ 255 − 30.8)
Range
-30.8 to 50.8 °C
Unit
°C

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Air conditioner feedback LEXUS_AC_FBConfirmed

  • Request21 51
  • Service 21PID 51
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 216 to 231 of the reply, 16 bits.

Formula
(val × 10 ÷ 8192 − 40)
Range
-40 to 39.99
Unit
Number

Confirmed for 2023. In testing for 2003 to 2022, 2025 to 2026. Not supported for 2024.

Air conditioning inverter gate LEXUS_AC_GATE

  • Request21 C4
  • Service 21PID C4
  • Module7E2
  • Every1 s
  • Testing

Bit 67 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Air conditioning power consumption LEXUS_AC_PWR

  • Request21 C4
  • Service 21PID C4
  • Module7E2
  • Every1 s
  • Testing

Bits 120 to 127 of the reply, 8 bits.

Formula
(val ÷ 51)
Range
0 to 5 kW
Unit
kW

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Air conditioning requested LEXUS_AC_REQ

  • Request21 C4
  • Service 21PID C4
  • Module7E2
  • Every1 s
  • Testing

Bit 14 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Air inlet damper actual pulse LEXUS_AIR_INLET_DAMPER_ACTUAL_PULSE

  • Request21 44
  • Service 21PID 44
  • Module7C4 → 7CC
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Air inlet damper target pulse LEXUS_AIR_INLET_DAMPER_TARGET_PULSE

  • Request21 44
  • Service 21PID 44
  • Module7C4 → 7CC
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Air mix servo, actual pulse, driver LEXUS_AIR_MIX_SERVO_ACT_D

  • Request21 41
  • Service 21PID 41
  • Module7C4 → 7CC
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Air outlet servo pulse, driver LEXUS_AIR_OUTLET_SERVO_PULSE_D

  • Request21 43
  • Service 21PID 43
  • Module7C4 → 7CC
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Air outlet servo, actual pulse, driver LEXUS_AIR_OUTLET_SERVO_ACTU_PULSE_D

  • Request21 43
  • Service 21PID 43
  • Module7C4 → 7CC
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Ambient air temperature LEXUS_AAT_V2

  • Request22 D1 12
  • Service 22DID D112
  • Module6F1 → 660
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 2 − 40)
Range
-40 to 87.5 °C
Unit
°C

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Ambient temperature LEXUS_AMBIENT_T_700Confirmed

  • Request22 1F 46
  • Service 22DID 1F46
  • Module700 → 708
  • Every1 s
  • Testing

Example reply from a 2024 Lexus GX.

Bits 0 to 7 of the reply, 8 bits.

0x1E = 30 → (30 − 40) = -10 °C

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2024. In testing for 2003 to 2023, 2025 to 2026.

Ambient temperature for A/C LEXUS_AC_AMB_TConfirmed

  • Request21 51
  • Service 21PID 51
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 88 to 95 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2023. In testing for 2003 to 2022, 2025 to 2026. Not supported for 2024.

Ambient temperature, alternate LEXUS_IA_AAT_ALT

  • Request22 05 7D
  • Service 22DID 057D
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 2 − 40)
Range
-40 to 87.5 °C
Unit
°C

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Ambient temperature, climate LEXUS_AAT_7C4_V2Confirmed

  • Request22 10 02
  • Service 22DID 1002
  • Module7C4 → 7CC
  • Every10 s
  • Testing

Example reply from a 2024 Lexus GX.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

0x071F = 1823 → (1823 ÷ 100) = 18.23 °C

Formula
(val ÷ 100)
Range
-327.68 to 327.67 °C
Unit
°C

Confirmed for 2024. In testing for 2003 to 2023, 2025 to 2026.

Blower level LEXUS_BLOWERConfirmed

  • Request22 28 01
  • Service 22DID 2801
  • Module7C4 → 7CC
  • Every10 s
  • Testing

Example reply from a 2024 Lexus GX.

Bits 0 to 7 of the reply, 8 bits.

0x00 = 0 → 0

Formula
val
Range
0 to 7
Unit
Number

Confirmed for 2024. In testing for 2003 to 2023, 2025 to 2026.

Blower motor speed level LEXUS_BLOWER_MOTOR_SPEED_LEVEL

  • Request21 3C
  • Service 21PID 3C
  • Module7C4 → 7CC
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Cabin mode active while parked LEXUS_MY_ROOM

  • Request22 16 92
  • Service 22DID 1692
  • Module745 → 74D
  • Every10 s
  • Testing

Bit 15 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Cabin temperature LEXUS_CABIN_T_V2Confirmed

  • Request22 10 01
  • Service 22DID 1001
  • Module7C4 → 7CC
  • Every10 s
  • Testing

Example reply from a 2024 Lexus GX.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

0x0795 = 1941 → (1941 ÷ 100) = 19.41 °C

Formula
(val ÷ 100)
Range
-327.68 to 327.67 °C
Unit
°C

Confirmed for 2024. In testing for 2003 to 2023, 2025 to 2026.

Climate control engine run requested LEXUS_HVAC_REQ

  • Request21 C4
  • Service 21PID C4
  • Module7E2
  • Every1 s
  • Testing

Bit 12 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Climate power, charging control LEXUS_HVAC_P_745

  • Request22 10 6E
  • Service 22DID 106E
  • Module745 → 74D
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 20)
Range
0 to 12.75 kW
Unit
kW

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Climate set point code LEXUS_HVAC_SET_RAWConfirmed

  • Request22 10 36
  • Service 22DID 1036
  • Module7C4 → 7CC
  • Every10 s
  • Testing

Example reply from a 2024 Lexus GX.

Bits 0 to 7 of the reply, 8 bits.

0x28 = 40 → 40

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2024. In testing for 2003 to 2023, 2025 to 2026.

Communication with air conditioner LEXUS_COMM_WITH_AIR_CONDITIONER

  • Request21 24
  • Service 21PID 24
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Communication with HV LEXUS_COMMUNICATION_WITH_HV

  • Request21 24
  • Service 21PID 24
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Communication with valvematic LEXUS_COMM_WITH_VALVEMATIC_COMM

  • Request21 24
  • Service 21PID 24
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Electric heater power count LEXUS_HEATER_RAW

  • Request22 10 86
  • Service 22DID 1086
  • Module7C4 → 7CC
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Evaporator fin thermistor LEXUS_EVAP_FIN_THERMISTOR

  • Request21 4B
  • Service 21PID 4B
  • Module7C4 → 7CC
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 89.25 ÷ 255 − 29.7)
Range
-29.7 to 59.55 °C
Unit
°C

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Set temperature, driver side LEXUS_T_DRIVER

  • Request21 29
  • Service 21PID 29
  • Module7C4 → 7CC
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 °C
Unit
°C

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Solar sensor, driver side LEXUS_SOLAR_DRIVER

  • Request21 24
  • Service 21PID 24
  • Module7C4 → 7CC
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Keyboard shortcuts

jk/↓↑
Move down or up through a list or a grid.
hl/←→
Move across a row or between cards.
Enter
Open the focused link.
f
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.