Kia K4

Battery parameters

The Kia K4 has 29 battery parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

12V battery state of charge K4_BATTERY_SOCConfirmed

  • Request22 E0 01
  • Service 22DID E001
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2024, 2026

Example reply from a 2025 Kia K4.

Bits 48 to 55 of the reply, 8 bits.

0x4A = 74 → 74 %

Formula
val
Range
0 to 255 %
Unit
%

Confirmed for 2025. In testing for 2024, 2026.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

12V battery state of charge K4_BATTERY_SOCConfirmed

  • Request22 E0 01
  • Service 22DID E001
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2024, 2026

Example reply from a 2025 Kia K4.

Bits 48 to 55 of the reply, 8 bits.

0x4A = 74 → 74 %

Formula
val
Range
0 to 255 %
Unit
%

Confirmed for 2025. In testing for 2024, 2026.

Battery capacity, battery sensor K4_BAT_CAP_BATSENS

  • Request22 ED 27
  • Service 22DID ED27
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 160 to 167 of the reply, 8 bits.

Formula
val
Range
0 to 255 Ah
Unit
Ah

In testing for 2024, 2026. Not supported for 2025.

Battery charge flag, battery sensor K4_BAT_CHG_FLAG_BATSENS

  • Request22 ED 27
  • Service 22DID ED27
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bit 183 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2024, 2026. Not supported for 2025.

Battery current K4_BAT_CURRENT

  • Request22 ED 27
  • Service 22DID ED27
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 256 to 271 of the reply, 16 bits. The value is signed.

Formula
(val × 1000 ÷ 10000)
Range
-3276.8 to 3276.7 A
Unit
A

In testing for 2024, 2026. Not supported for 2025.

Battery current, battery sensor K4_BAT_CURRENT_BATSENS

  • Request22 ED 27
  • Service 22DID ED27
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 48 to 55 of the reply, 8 bits.

Formula
(val ÷ 10)
Range
0 to 25.5 A
Unit
A

In testing for 2024, 2026. Not supported for 2025.

Battery health aging flag, battery sensor K4_BAT_HEALTH_AGING

  • Request22 ED 27
  • Service 22DID ED27
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bit 182 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2024, 2026. Not supported for 2025.

Battery is in use to crank the engine flag, battery sensor K4_BAT_CRANK_ENG_FLAG

  • Request22 ED 27
  • Service 22DID ED27
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bit 181 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2024, 2026. Not supported for 2025.

Battery quiescent current flag, battery sensor K4_BAT_QUIESCENT

  • Request22 ED 27
  • Service 22DID ED27
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bit 180 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2024, 2026. Not supported for 2025.

Battery sensor invalid condition flag, battery sensor K4_BATSENS_INVALID_COND

  • Request22 ED 27
  • Service 22DID ED27
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bit 179 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2024, 2026. Not supported for 2025.

Battery state of charge, battery sensor K4_BAT_ST_CHG_BATSENS

  • Request22 ED 27
  • Service 22DID ED27
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 72 to 79 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2024, 2026. Not supported for 2025.

Battery state of function, battery sensor K4_BAT_ST_FUNCTION

  • Request22 ED 27
  • Service 22DID ED27
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 88 to 95 of the reply, 8 bits.

Formula
(val × 12.75 ÷ 255)
Range
0 to 12.75 V
Unit
V

In testing for 2024, 2026. Not supported for 2025.

Battery state of health, battery sensor K4_BAT_ST_HEALTH

  • Request22 ED 27
  • Service 22DID ED27
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 80 to 87 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2024, 2026. Not supported for 2025.

Battery temperature K4_BAT_T

  • Request22 ED 27
  • Service 22DID ED27
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 288 to 303 of the reply, 16 bits.

Formula
(val ÷ 2)
Range
0 to 32767.5 °C
Unit
°C

In testing for 2024, 2026. Not supported for 2025.

Battery temperature, battery sensor K4_BAT_T_BATSENS

  • Request22 ED 27
  • Service 22DID ED27
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 64 to 71 of the reply, 8 bits.

Formula
(val ÷ 2 − 40)
Range
-40 to 87.5 °C
Unit
°C

In testing for 2024, 2026. Not supported for 2025.

Battery voltage K4_BAT_V

  • Request22 ED 27
  • Service 22DID ED27
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 272 to 287 of the reply, 16 bits.

Formula
(val × 10 ÷ 10000 + 6)
Range
0 to 71.535 V
Unit
V

In testing for 2024, 2026. Not supported for 2025.

Battery voltage K4_BATTERY_VConfirmed

  • Request22 E0 01
  • Service 22DID E001
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2024, 2026

Example reply from a 2025 Kia K4.

Bits 32 to 39 of the reply, 8 bits.

0xCD = 205 → (205 × 17.37 ÷ 255) = 13.964118 V

Formula
(val × 17.37 ÷ 255)
Range
0 to 17.37 V
Unit
V

Confirmed for 2025. In testing for 2024, 2026.

Battery voltage after ignition K4_BATTERY_V_AFTER_IGNITIONConfirmed

  • Request22 E0 01
  • Service 22DID E001
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2024, 2026

Example reply from a 2025 Kia K4.

Bits 40 to 47 of the reply, 8 bits.

0xCD = 205 → (205 × 17.37 ÷ 255) = 13.964118 V

Formula
(val × 17.37 ÷ 255)
Range
0 to 17.37 V
Unit
V

Confirmed for 2025. In testing for 2024, 2026.

Battery voltage, battery sensor K4_BAT_V_BATSENS

Pelican can show this parameter as the starter battery voltage.

  • Request22 ED 27
  • Service 22DID ED27
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 56 to 63 of the reply, 8 bits.

Formula
(val × 12.75 ÷ 255 + 6)
Range
0 to 18.75 V
Unit
V

In testing for 2024, 2026. Not supported for 2025.

Control module voltage K4_CONTROL_MODULE_VOLTAGE

  • Request21 01
  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
val
Range
0 to 255 V
Unit
V

In testing for 2024, 2026. Not supported for 2025.

Control module voltage VPWRSAE J1979Confirmed

Power input to the OBD control module. VPWR is normally battery voltage, less any voltage drop in the circuit between the battery and the control module.

Pelican can show this parameter as the starter battery voltage.

  • Request01 42
  • Service 01PID 42
  • Module7E0 → 7E8
  • Every10 s

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65535 V
Unit
V

Confirmed for 2025.

Control module voltage after ignition K4_CONTROL_MODULE_VOLTAGE_AFTER_IGNITION

  • Request21 01
  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 48 to 55 of the reply, 8 bits.

Formula
val
Range
0 to 255 V
Unit
V

In testing for 2024, 2026. Not supported for 2025.

Coolant temperature sensor voltage K4_COOLANT_T_SENSOR_VOLTAGE

  • Request21 01
  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 184 to 199 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val × 0.0048828125)
Range
0 to 319 V
Unit
V

In testing for 2024, 2026. Not supported for 2025.

IAT sensor voltage K4_IAT_SENSOR_VOLTAGE

  • Request21 01
  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 248 to 263 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val × 0.0048828125)
Range
0 to 319 V
Unit
V

In testing for 2024, 2026. Not supported for 2025.

Manifold absolute pressure sensor voltage K4_MAP_SENSOR_VOLTAGE

  • Request21 01
  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 112 to 127 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val × 0.0048828125)
Range
0 to 319 V
Unit
V

In testing for 2024, 2026. Not supported for 2025.

Relative accelerator pedal position voltage K4_RELATIVE_ACCELERATOR_PEDAL_POSITION_VOLTAGE

  • Request21 14
  • Service 21PID 14
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 112 to 127 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
(val ÷ 5)
Range
-6553.6 to 6553.4 V
Unit
V

In testing for 2024, 2026. Not supported for 2025.

Response error from battery sensor flag, battery sensor K4_RESPONSE_ERROR

  • Request22 ED 27
  • Service 22DID ED27
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bit 178 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2024, 2026. Not supported for 2025.

Throttle position sensor voltage #1 K4_THROTTLE_POSITION_SENSOR_VOLTAGE__1

  • Request21 14
  • Service 21PID 14
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 360 to 375 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val × 0.0012207031)
Range
0 to 79 V
Unit
V

In testing for 2024, 2026. Not supported for 2025.

Throttle position sensor voltage #2 K4_THROTTLE_POSITION_SENSOR_VOLTAGE__2

  • Request21 14
  • Service 21PID 14
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 80 to 95 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val × 0.0012207031)
Range
0 to 79 V
Unit
V

In testing for 2024, 2026. Not supported for 2025.

Wastegate position voltage K4_WASTEGATE_POS_V

  • Request21 19
  • Service 21PID 19
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 400 to 415 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
(val × 1.53 ÷ 10000)
Range
-5.01 to 5.01 V
Unit
V

In testing for 2024, 2026. Not supported for 2025.

Keyboard shortcuts

jk/↓↑
Move down or up through a list or a grid.
hl/←→
Move across a row or between cards.
Enter
Open the focused link.
f
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.