Engine parameters
The Kia Forte has 235 engine parameters.
● Confirmed◆ In testing○ Supported× Not supported
Absolute load value LOAD_ABSSAE J1979Confirmed
- Request
01 43 - Service 01
PID 43 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 25700 %
- Unit
- %
Confirmed for 2017, 2022 to 2024. Supported for 2010 to 2014, 2016, 2018 to 2021.
Actual engine torque TQ_ACTSAE J1979Confirmed
- Request
01 62 - Service 01
PID 62 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 125)- Range
- -125 to 130 %
- Unit
- %
Confirmed for 2022 to 2024. Supported for 2019.
Adaptation value for lower stop of wastegate actuator FORTE_ADPT_LO_STOP
- Request
21 19 - Service 21
PID 19 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 384 to 399 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
(val × 1.53 ÷ 10000)- Range
- -5.01 to 5.01 V
- Unit
- V
In testing for 2008 to 2022. Not supported for 2023 to 2024.
Air conditioning pressure FORTE_AC_PConfirmed
- Request
22 E0 14 - Service 22
DID E014 - Module
7E0 → 7E8 - Every
5 s - Testing for 2008 to 2022
Example reply from a 2024 Kia Forte.
Bits 112 to 119 of the reply, 8 bits.
0x37 = 55 → (55 × 3520 ÷ 255) = 759.215686 kPa
- Formula
(val × 3520 ÷ 255)- Range
- 0 to 3520 kPa
- Unit
- kPa
Confirmed for 2023 to 2024. In testing for 2008 to 2022.
Air conditioning relay FORTE_AC_RELAY
- Request
22 ED 01 - Service 22
DID ED01 - Module
7E0 → 7E8 - Every
5 s - Testing
Bit 101 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2008 to 2022. Not supported for 2023 to 2024.
Air flow rate from mass air flow sensor MAFSAE J1979Confirmed
Pelican can show this parameter as the mass air flow.
- Request
01 10 - Service 01
PID 10 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655.35 g/s
- Unit
- g/s
Confirmed for 2019 to 2020, 2022 to 2024. Supported for 2021.
Automatic transmission fluid temperature FORTE_ATF_T_7E1Confirmed
Pelican can show this parameter as the transmission fluid temperature.
- Request
22 01 A0 - Service 22
DID 01A0 - Module
7E1 → 7E9 - Every
250 ms - Testing for 2008 to 2022
Example reply from a 2024 Kia Forte.
Bits 104 to 111 of the reply, 8 bits.
0x77 = 119 → (119 − 40) = 79 °C
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2023 to 2024. In testing for 2008 to 2022.
Barometric pressure BAROSAE J1979Confirmed
Normally obtained from one of a dedicated barometric sensor, a MAP sensor at key-on and during certain modes of driving, or inferred from a MAF sensor and other inputs during certain modes of driving. The control module reports BARO from whatever source it is derived from.
- Request
01 33 - Service 01
PID 33 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 kPa
- Unit
- kPa
Confirmed for 2017, 2022 to 2024. Supported for 2010 to 2014, 2016, 2018 to 2021.
Barometric pressure FORTE_BAROMETRIC_PRESSURE
- Request
21 13 - Service 21
PID 13 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 312 to 319 of the reply, 8 bits.
- Formula
(val ÷ 2)- Range
- 0 to 127.5 kPa
- Unit
- kPa
In testing for 2008 to 2022. Not supported for 2023 to 2024.
Boost pressure upstream FORTE_BOOST_P_UP
- Request
22 E0 03 - Service 22
DID E003 - Module
7E0 → 7E8 - Every
1 s - Testing for 2008 to 2022
Bits 280 to 295 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val × 39 ÷ 500)- Range
- 0 to 5111
- Unit
- Raw value
In testing for 2008 to 2022. Supported for 2023 to 2024.
Boost pressure upstream, desired FORTE_BOOST_P_UP_DES
- Request
22 E0 03 - Service 22
DID E003 - Module
7E0 → 7E8 - Every
1 s - Testing for 2008 to 2022
Bits 312 to 327 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val × 39 ÷ 500)- Range
- 0 to 5111
- Unit
- Raw value
In testing for 2008 to 2022. Supported for 2023 to 2024.
Calculated engine load LOAD_PCTSAE J1979Confirmed
Represents the amount of work the engine is doing. Expected to reach 100% at wide open throttle/wide open pedal at any altitude, temperature or rpm for both naturally aspirated and boosted engines. If engine load is limited for powertrain protection e.g. engine/turbocharger protection, this value may not reach 100%. For hybrid vehicles, indicates the torque produced only by the internal combustion engine, not the torque being delivered by the entire powertrain. For electric vehicles, the meaning of this parameter is undefined.
Pelican can show this parameter as the engine load.
- Request
01 04 - Service 01
PID 04 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2013 to 2014, 2017 to 2020, 2022 to 2024. Supported for 2010 to 2012, 2016, 2021.
Calculated oil temperature FORTE_CALC_OIL_TConfirmed
- Request
22 E0 11 - Service 22
DID E011 - Module
7E0 → 7E8 - Every
5 s - Testing for 2008 to 2022
Example reply from a 2024 Kia Forte.
Bits 304 to 311 of the reply, 8 bits.
0x69 = 105 → (105 − 40) = 65 °C
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2023 to 2024. In testing for 2008 to 2022.
Catalyst damaging misfires all cylinders FORTE_CATDMG_MIS_ALL
- Request
21 08 - Service 21
PID 08 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 400 to 415 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2008 to 2022. Not supported for 2023 to 2024.
Catalyst damaging misfires total all cylinders FORTE_CATALYST_DAMAGING_MISFIRES_TOTAL_ALL_CYLINDERS
- Request
22 E0 0D - Service 22
DID E00D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 448 to 463 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2008 to 2022. Not supported for 2023 to 2024.
Catalyst damaging misfires total, cylinder 1 FORTE_CATALYST_DAMAGING_MISFIRES_TOTAL_C1
- Request
22 E0 0D - Service 22
DID E00D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 304 to 319 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2008 to 2022. Not supported for 2023 to 2024.
Catalyst damaging misfires total, cylinder 1 FORTE_CATDMG_MIS_TOT_1Confirmed
- Request
22 E0 1D - Service 22
DID E01D - Module
7E0 → 7E8 - Every
1 s - Testing for 2008 to 2022
Example reply from a 2024 Kia Forte.
Bits 160 to 175 of the reply, 16 bits. The bytes are in little-endian order.
0x0000 = 0 → 0
- Formula
val- Range
- 0 to 65535
- Unit
- Number
Confirmed for 2023 to 2024. In testing for 2008 to 2022.
Catalyst damaging misfires total, cylinder 2 FORTE_CATALYST_DAMAGING_MISFIRES_TOTAL_C2
- Request
22 E0 0D - Service 22
DID E00D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 320 to 335 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2008 to 2022. Not supported for 2023 to 2024.
Catalyst damaging misfires total, cylinder 2 FORTE_CATDMG_MIS_TOT_2Confirmed
- Request
22 E0 1D - Service 22
DID E01D - Module
7E0 → 7E8 - Every
1 s - Testing for 2008 to 2022
Example reply from a 2024 Kia Forte.
Bits 176 to 191 of the reply, 16 bits. The bytes are in little-endian order.
0x0000 = 0 → 0
- Formula
val- Range
- 0 to 65535
- Unit
- Number
Confirmed for 2023 to 2024. In testing for 2008 to 2022.
Catalyst damaging misfires total, cylinder 3 FORTE_CATALYST_DAMAGING_MISFIRES_TOTAL_C3
- Request
22 E0 0D - Service 22
DID E00D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 336 to 351 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2008 to 2022. Not supported for 2023 to 2024.
Catalyst damaging misfires total, cylinder 3 FORTE_CATDMG_MIS_TOT_3Confirmed
- Request
22 E0 1D - Service 22
DID E01D - Module
7E0 → 7E8 - Every
1 s - Testing for 2008 to 2022
Example reply from a 2024 Kia Forte.
Bits 192 to 207 of the reply, 16 bits. The bytes are in little-endian order.
0x0000 = 0 → 0
- Formula
val- Range
- 0 to 65535
- Unit
- Number
Confirmed for 2023 to 2024. In testing for 2008 to 2022.
Catalyst damaging misfires total, cylinder 4 FORTE_CATALYST_DAMAGING_MISFIRES_TOTAL_C4
- Request
22 E0 0D - Service 22
DID E00D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 352 to 367 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2008 to 2022. Not supported for 2023 to 2024.
Catalyst damaging misfires total, cylinder 4 FORTE_CATDMG_MIS_TOT_4Confirmed
- Request
22 E0 1D - Service 22
DID E01D - Module
7E0 → 7E8 - Every
1 s - Testing for 2008 to 2022
Example reply from a 2024 Kia Forte.
Bits 208 to 223 of the reply, 16 bits. The bytes are in little-endian order.
0x0000 = 0 → 0
- Formula
val- Range
- 0 to 65535
- Unit
- Number
Confirmed for 2023 to 2024. In testing for 2008 to 2022.
Catalyst damaging misfires, cylinder 1 FORTE_CATDMG_MIS_1
- Request
21 08 - Service 21
PID 08 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 256 to 271 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2008 to 2022. Not supported for 2023 to 2024.
Catalyst damaging misfires, cylinder 2 FORTE_CATDMG_MIS_2
- Request
21 08 - Service 21
PID 08 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 272 to 287 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2008 to 2022. Not supported for 2023 to 2024.
Catalyst damaging misfires, cylinder 3 FORTE_CATDMG_MIS_3
- Request
21 08 - Service 21
PID 08 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 288 to 303 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2008 to 2022. Not supported for 2023 to 2024.
Catalyst damaging misfires, cylinder 4 FORTE_CATDMG_MIS_4
- Request
21 08 - Service 21
PID 08 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 304 to 319 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2008 to 2022. Not supported for 2023 to 2024.
Catalyst damaging misfires, cylinder 5 FORTE_CATDMG_MIS_5
- Request
21 08 - Service 21
PID 08 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 320 to 335 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2008 to 2022. Not supported for 2023 to 2024.
Catalyst damaging misfires, cylinder 6 FORTE_CATDMG_MIS_6
- Request
21 08 - Service 21
PID 08 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 336 to 351 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2008 to 2022. Not supported for 2023 to 2024.
Catalyst temperature bank 1, sensor 1 CATEMP11SAE J1979Confirmed
- Request
01 3C - Service 01
PID 3C - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10 − 40)- Range
- -40 to 6513.5 °C
- Unit
- °C
Confirmed for 2017, 2022 to 2024. Supported for 2010 to 2014, 2016, 2018 to 2021.
Catalyst temperature bank 1, sensor 2 CATEMP12SAE J1979Confirmed
- Request
01 3E - Service 01
PID 3E - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10 − 40)- Range
- -40 to 6513.5 °C
- Unit
- °C
Confirmed for 2022. Supported for 2010 to 2013, 2016 to 2021, 2023.
Commanded EGR EGR_PCTSAE J1979Confirmed
- Request
01 2C - Service 01
PID 2C - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2022. Supported for 2019 to 2021, 2023 to 2024.
Commanded equivalence ratio EQ_RATSAE J1979Confirmed
Fuel systems that utilize conventional oxygen sensor display the inverse of the commanded open loop equivalence ratio (also known as lambda) while the fuel control system is in open loop. Will indicate 1.000 while in closed-loop fuel.
Pelican can show this parameter as the commanded lambda.
- Request
01 44 - Service 01
PID 44 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 2 ÷ 65535)- Range
- 0 to 1.99
- Unit
- Number
Confirmed for 2013 to 2014, 2017 to 2020, 2022 to 2024. Supported for 2010 to 2012, 2016, 2021.
Commanded evaporative purge EVAP_PCTSAE J1979Confirmed
- Request
01 2E - Service 01
PID 2E - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2017, 2022 to 2023. Supported for 2010 to 2014, 2016, 2018 to 2021, 2024.
Commanded evaporative purge FORTE_COMMANDED_EVAPORATIVE_PURGE
- Request
21 02 - Service 21
PID 02 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 160 to 167 of the reply, 8 bits.
- Formula
(val × 0.390625)- Range
- 0 to 99.6 %
- Unit
- %
In testing for 2008 to 2022. Not supported for 2023 to 2024.
Commanded throttle actuator FORTE_COMMANDED_THROTTLE_ACTUATOR
- Request
21 14 - Service 21
PID 14 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val × 0.390625)- Range
- 0 to 99.6 %
- Unit
- %
In testing for 2008 to 2022. Not supported for 2023 to 2024.
Commanded throttle actuator control TAC_PCTSAE J1979Confirmed
- Request
01 4C - Service 01
PID 4C - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2017, 2022 to 2023. Supported for 2019.
Coolant FORTE_COOLANT_FAN
- Request
21 14 - Service 21
PID 14 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 96 to 103 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2008 to 2022. Not supported for 2023 to 2024.
Coolant fan PWM FORTE_CLT_FAN_PWMConfirmed
- Request
22 E0 14 - Service 22
DID E014 - Module
7E0 → 7E8 - Every
5 s - Testing for 2008 to 2022
Example reply from a 2024 Kia Forte.
Bits 88 to 95 of the reply, 8 bits.
0x00 = 0 → (0 × 100 ÷ 255) = 0 %
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2023 to 2024. In testing for 2008 to 2022.
Coolant temperature FORTE_HVAC_COOLANT_TConfirmed
- Request
22 01 02 - Service 22
DID 0102 - Module
7B3 → 7BB - Every
1 s - Testing for 2008 to 2022
Example reply from a 2024 Kia Forte.
Bits 32 to 39 of the reply, 8 bits.
0xFF = 255 → (255 ÷ 2 − 40) = 87.5 °C
- Formula
(val ÷ 2 − 40)- Range
- -40 to 87.5 °C
- Unit
- °C
Confirmed for 2023 to 2024. In testing for 2008 to 2022.
Crankshaft torque FORTE_CRANK_TQ
- Request
22 ED 05 - Service 22
DID ED05 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 240 to 247 of the reply, 8 bits.
- Formula
(val × 600 ÷ 255)- Range
- 0 to 600 N·m
- Unit
- N·m
In testing for 2008 to 2022. Not supported for 2023 to 2024.
Cylinder 1 injection time, 1st pulse FORTE_CYL_1_INJ_TIME_1ST
- Request
21 23 - Service 21
PID 23 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 264 to 279 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val × 4 ÷ 1000)- Range
- 0 to 262.14 ms
- Unit
- ms
In testing for 2008 to 2022. Not supported for 2023 to 2024.
Cylinder 1 injection time, 2nd pulse FORTE_CYL_1_INJ_TIME_2ND
- Request
21 23 - Service 21
PID 23 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 200 to 215 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val × 4 ÷ 1000)- Range
- 0 to 262.14 ms
- Unit
- ms
In testing for 2008 to 2022. Not supported for 2023 to 2024.
Cylinder 2 injection time, 1st pulse FORTE_CYL_2_INJ_TIME_1ST
- Request
21 23 - Service 21
PID 23 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 280 to 295 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val × 4 ÷ 1000)- Range
- 0 to 262.14 ms
- Unit
- ms
In testing for 2008 to 2022. Not supported for 2023 to 2024.
Cylinder 2 injection time, 2nd pulse FORTE_CYL_2_INJ_TIME_2ND
- Request
21 23 - Service 21
PID 23 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 216 to 231 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val × 4 ÷ 1000)- Range
- 0 to 262.14 ms
- Unit
- ms
In testing for 2008 to 2022. Not supported for 2023 to 2024.
Cylinder 3 injection time, 1st pulse FORTE_CYL_3_INJ_TIME_1ST
- Request
21 23 - Service 21
PID 23 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 296 to 311 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val × 4 ÷ 1000)- Range
- 0 to 262.14 ms
- Unit
- ms
In testing for 2008 to 2022. Not supported for 2023 to 2024.
Cylinder 3 injection time, 2nd pulse FORTE_CYL_3_INJ_TIME_2ND
- Request
21 23 - Service 21
PID 23 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 232 to 247 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val × 4 ÷ 1000)- Range
- 0 to 262.14 ms
- Unit
- ms
In testing for 2008 to 2022. Not supported for 2023 to 2024.
Cylinder 4 injection time, 1st pulse FORTE_CYL_4_INJ_TIME_1ST
- Request
21 23 - Service 21
PID 23 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 312 to 327 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val × 4 ÷ 1000)- Range
- 0 to 262.14 ms
- Unit
- ms
In testing for 2008 to 2022. Not supported for 2023 to 2024.
Cylinder 4 injection time, 2nd pulse FORTE_CYL_4_INJ_TIME_2ND
- Request
21 23 - Service 21
PID 23 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 248 to 263 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val × 4 ÷ 1000)- Range
- 0 to 262.14 ms
- Unit
- ms
In testing for 2008 to 2022. Not supported for 2023 to 2024.
Diesel particulate filter regeneration count FORTE_DPF_REGEN_CNT
- Request
22 ED 03 - Service 22
DID ED03 - Module
7E0 → 7E8 - Every
30 s - Testing
Bits 440 to 447 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2008 to 2022. Not supported for 2023 to 2024.
Diesel particulate filter regeneration state FORTE_DPF_REGEN_ST
- Request
22 ED 03 - Service 22
DID ED03 - Module
7E0 → 7E8 - Every
30 s - Testing
Bit 431 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2008 to 2022. Not supported for 2023 to 2024.
Direct injection time 1 FORTE_DI_TIME_1
- Request
21 0B - Service 21
PID 0B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 32 to 47 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val × 100 ÷ 13107)- Range
- 0 to 500 ms
- Unit
- ms
In testing for 2008 to 2022. Not supported for 2023 to 2024.
Direct injection time 1st pulse, cylinder 1 FORTE_DI_TIME_1ST_CYL_1Confirmed
- Request
22 E0 23 - Service 22
DID E023 - Module
7E0 → 7E8 - Every
1 s - Testing for 2008 to 2022
Example reply from a 2024 Kia Forte.
Bits 264 to 279 of the reply, 16 bits. The bytes are in little-endian order.
0x0000 = 0 → (0 × 4 ÷ 1000) = 0 ms
- Formula
(val × 4 ÷ 1000)- Range
- 0 to 262.14 ms
- Unit
- ms
Confirmed for 2023 to 2024. In testing for 2008 to 2022.
Direct injection time 1st pulse, cylinder 2 FORTE_DI_TIME_1ST_CYL_2Confirmed
- Request
22 E0 23 - Service 22
DID E023 - Module
7E0 → 7E8 - Every
1 s - Testing for 2008 to 2022
Example reply from a 2024 Kia Forte.
Bits 280 to 295 of the reply, 16 bits. The bytes are in little-endian order.
0x0000 = 0 → (0 × 4 ÷ 1000) = 0 ms
- Formula
(val × 4 ÷ 1000)- Range
- 0 to 262.14 ms
- Unit
- ms
Confirmed for 2023 to 2024. In testing for 2008 to 2022.
Direct injection time 1st pulse, cylinder 3 FORTE_DI_TIME_1ST_CYL_3Confirmed
- Request
22 E0 23 - Service 22
DID E023 - Module
7E0 → 7E8 - Every
1 s - Testing for 2008 to 2022
Example reply from a 2024 Kia Forte.
Bits 296 to 311 of the reply, 16 bits. The bytes are in little-endian order.
0x0000 = 0 → (0 × 4 ÷ 1000) = 0 ms
- Formula
(val × 4 ÷ 1000)- Range
- 0 to 262.14 ms
- Unit
- ms
Confirmed for 2023 to 2024. In testing for 2008 to 2022.
Direct injection time 1st pulse, cylinder 4 FORTE_DI_TIME_1ST_CYL_4Confirmed
- Request
22 E0 23 - Service 22
DID E023 - Module
7E0 → 7E8 - Every
1 s - Testing for 2008 to 2022
Example reply from a 2024 Kia Forte.
Bits 312 to 327 of the reply, 16 bits. The bytes are in little-endian order.
0x0000 = 0 → (0 × 4 ÷ 1000) = 0 ms
- Formula
(val × 4 ÷ 1000)- Range
- 0 to 262.14 ms
- Unit
- ms
Confirmed for 2023 to 2024. In testing for 2008 to 2022.
Direct injection time 1st pulse, cylinder 5 FORTE_CYL5_INJ_TIME_1ST
- Request
22 E0 23 - Service 22
DID E023 - Module
7E0 → 7E8 - Every
1 s - Testing for 2008 to 2022
Bits 392 to 407 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val × 4 ÷ 1000)- Range
- 0 to 262.14 ms
- Unit
- ms
In testing for 2008 to 2022. Supported for 2023 to 2024.
Direct injection time 1st pulse, cylinder 6 FORTE_CYL6_INJ_TIME_1ST
- Request
22 E0 23 - Service 22
DID E023 - Module
7E0 → 7E8 - Every
1 s - Testing for 2008 to 2022
Bits 408 to 423 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val × 4 ÷ 1000)- Range
- 0 to 262.14 ms
- Unit
- ms
In testing for 2008 to 2022. Supported for 2023 to 2024.
Direct injection time 2 FORTE_DI_TIME_2
- Request
21 0B - Service 21
PID 0B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 48 to 63 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val × 100 ÷ 13107)- Range
- 0 to 500 ms
- Unit
- ms
In testing for 2008 to 2022. Not supported for 2023 to 2024.
Direct injection time 2nd pulse, cylinder 1 FORTE_DI_TIME_2ND_CYL_1Confirmed
- Request
22 E0 23 - Service 22
DID E023 - Module
7E0 → 7E8 - Every
1 s - Testing for 2008 to 2022
Example reply from a 2024 Kia Forte.
Bits 200 to 215 of the reply, 16 bits. The bytes are in little-endian order.
0x0000 = 0 → (0 × 4 ÷ 1000) = 0 ms
- Formula
(val × 4 ÷ 1000)- Range
- 0 to 262.14 ms
- Unit
- ms
Confirmed for 2023 to 2024. In testing for 2008 to 2022.
Direct injection time 2nd pulse, cylinder 2 FORTE_DI_TIME_2ND_CYL_2Confirmed
- Request
22 E0 23 - Service 22
DID E023 - Module
7E0 → 7E8 - Every
1 s - Testing for 2008 to 2022
Example reply from a 2024 Kia Forte.
Bits 216 to 231 of the reply, 16 bits. The bytes are in little-endian order.
0x0000 = 0 → (0 × 4 ÷ 1000) = 0 ms
- Formula
(val × 4 ÷ 1000)- Range
- 0 to 262.14 ms
- Unit
- ms
Confirmed for 2023 to 2024. In testing for 2008 to 2022.
Direct injection time 2nd pulse, cylinder 3 FORTE_DI_TIME_2ND_CYL_3Confirmed
- Request
22 E0 23 - Service 22
DID E023 - Module
7E0 → 7E8 - Every
1 s - Testing for 2008 to 2022
Example reply from a 2024 Kia Forte.
Bits 232 to 247 of the reply, 16 bits. The bytes are in little-endian order.
0x0000 = 0 → (0 × 4 ÷ 1000) = 0 ms
- Formula
(val × 4 ÷ 1000)- Range
- 0 to 262.14 ms
- Unit
- ms
Confirmed for 2023 to 2024. In testing for 2008 to 2022.
Direct injection time 2nd pulse, cylinder 4 FORTE_DI_TIME_2ND_CYL_4Confirmed
- Request
22 E0 23 - Service 22
DID E023 - Module
7E0 → 7E8 - Every
1 s - Testing for 2008 to 2022
Example reply from a 2024 Kia Forte.
Bits 248 to 263 of the reply, 16 bits. The bytes are in little-endian order.
0x0000 = 0 → (0 × 4 ÷ 1000) = 0 ms
- Formula
(val × 4 ÷ 1000)- Range
- 0 to 262.14 ms
- Unit
- ms
Confirmed for 2023 to 2024. In testing for 2008 to 2022.
Direct injection time 2nd pulse, cylinder 5 FORTE_CYL5_INJ_TIME_2ND
- Request
22 E0 23 - Service 22
DID E023 - Module
7E0 → 7E8 - Every
1 s - Testing for 2008 to 2022
Bits 360 to 375 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val × 4 ÷ 1000)- Range
- 0 to 262.14 ms
- Unit
- ms
In testing for 2008 to 2022. Supported for 2023 to 2024.
Direct injection time 2nd pulse, cylinder 6 FORTE_CYL6_INJ_TIME_2ND
- Request
22 E0 23 - Service 22
DID E023 - Module
7E0 → 7E8 - Every
1 s - Testing for 2008 to 2022
Bits 376 to 391 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val × 4 ÷ 1000)- Range
- 0 to 262.14 ms
- Unit
- ms
In testing for 2008 to 2022. Supported for 2023 to 2024.
Direct injection time 3 FORTE_DI_TIME_3
- Request
21 0B - Service 21
PID 0B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 64 to 79 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val × 100 ÷ 13107)- Range
- 0 to 500 ms
- Unit
- ms
In testing for 2008 to 2022. Not supported for 2023 to 2024.
Direct injection time 4 FORTE_DI_TIME_4
- Request
21 0B - Service 21
PID 0B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 80 to 95 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val × 100 ÷ 13107)- Range
- 0 to 500 ms
- Unit
- ms
In testing for 2008 to 2022. Not supported for 2023 to 2024.
Direct injection time 5 FORTE_DI_TIME_5
- Request
21 0B - Service 21
PID 0B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 96 to 111 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val × 100 ÷ 13107)- Range
- 0 to 500 ms
- Unit
- ms
In testing for 2008 to 2022. Not supported for 2023 to 2024.
Direct injection time 6 FORTE_DI_TIME_6
- Request
21 0B - Service 21
PID 0B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 112 to 127 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val × 100 ÷ 13107)- Range
- 0 to 500 ms
- Unit
- ms
In testing for 2008 to 2022. Not supported for 2023 to 2024.
Dual-clutch transmission clutch 1, pressure sensor a FORTE_DUAL_CLU_TRANS_CLU_1_P
- Request
22 01 A5 - Service 22
DID 01A5 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 192 to 207 of the reply, 16 bits.
- Formula
(val × 19.53 ÷ 10000)- Range
- 0 to 127 bar
- Unit
- bar
In testing for 2008 to 2022. Not supported for 2023 to 2024.
Dual-clutch transmission clutch 2, pressure sensor b FORTE_DUAL_CLU_TRANS_CLU_2_P_B
- Request
22 01 A5 - Service 22
DID 01A5 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 208 to 223 of the reply, 16 bits.
- Formula
(val × 19.53 ÷ 10000)- Range
- 0 to 127 bar
- Unit
- bar
In testing for 2008 to 2022. Not supported for 2023 to 2024.
Dual-clutch transmission fluid temperature 1 FORTE_DUAL_CLU_ATF_T_1
- Request
22 01 A5 - Service 22
DID 01A5 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 48 to 55 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2008 to 2022. Not supported for 2023 to 2024.
Dual-clutch transmission fluid temperature 2 FORTE_DUAL_CLU_ATF_T_2
- Request
22 01 A5 - Service 22
DID 01A5 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 56 to 63 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2008 to 2022. Not supported for 2023 to 2024.
Dual-clutch transmission line pressure, sensor c FORTE_DUAL_CLU_TRANS_LINE_P_C
- Request
22 01 A5 - Service 22
DID 01A5 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 224 to 239 of the reply, 16 bits.
- Formula
(val × 19.53 ÷ 10000)- Range
- 0 to 127 bar
- Unit
- bar
In testing for 2008 to 2022. Not supported for 2023 to 2024.
EGR error EGR_ERRSAE J1979Confirmed
- Request
01 2D - Service 01
PID 2D - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 128 − 100)- Range
- -100 to 99.22 %
- Unit
- %
Confirmed for 2022. Supported for 2019 to 2021, 2023 to 2024.
Emission relevant misfires all cylinders FORTE_EMIS_MIS_ALL
- Request
21 08 - Service 21
PID 08 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 384 to 399 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2008 to 2022. Not supported for 2023 to 2024.
Emission relevant misfires total all cylinders FORTE_EMISSION_RELEVANT_MISFIRES_TOTAL_ALL_CYLINDERS
- Request
22 E0 0D - Service 22
DID E00D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 432 to 447 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2008 to 2022. Not supported for 2023 to 2024.
Emission relevant misfires total, cylinder 1 FORTE_EMIS_MIS_TOT_1Confirmed
- Request
22 E0 1D - Service 22
DID E01D - Module
7E0 → 7E8 - Every
1 s - Testing for 2008 to 2022
Example reply from a 2024 Kia Forte.
Bits 32 to 47 of the reply, 16 bits. The bytes are in little-endian order.
0x0000 = 0 → 0
- Formula
val- Range
- 0 to 65535
- Unit
- Number
Confirmed for 2023 to 2024. In testing for 2008 to 2022.
Emission relevant misfires total, cylinder 1 FORTE_EMISSION_RELEVANT_MISFIRES_TOTAL_C1
- Request
22 E0 0D - Service 22
DID E00D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 176 to 191 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2008 to 2022. Not supported for 2023 to 2024.
Emission relevant misfires total, cylinder 2 FORTE_EMIS_MIS_TOT_2Confirmed
- Request
22 E0 1D - Service 22
DID E01D - Module
7E0 → 7E8 - Every
1 s - Testing for 2008 to 2022
Example reply from a 2024 Kia Forte.
Bits 48 to 63 of the reply, 16 bits. The bytes are in little-endian order.
0x0000 = 0 → 0
- Formula
val- Range
- 0 to 65535
- Unit
- Number
Confirmed for 2023 to 2024. In testing for 2008 to 2022.
Emission relevant misfires total, cylinder 2 FORTE_EMISSION_RELEVANT_MISFIRES_TOTAL_C2
- Request
22 E0 0D - Service 22
DID E00D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 192 to 207 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2008 to 2022. Not supported for 2023 to 2024.
Emission relevant misfires total, cylinder 3 FORTE_EMIS_MIS_TOT_3Confirmed
- Request
22 E0 1D - Service 22
DID E01D - Module
7E0 → 7E8 - Every
1 s - Testing for 2008 to 2022
Example reply from a 2024 Kia Forte.
Bits 64 to 79 of the reply, 16 bits. The bytes are in little-endian order.
0x0000 = 0 → 0
- Formula
val- Range
- 0 to 65535
- Unit
- Number
Confirmed for 2023 to 2024. In testing for 2008 to 2022.
Emission relevant misfires total, cylinder 3 FORTE_EMISSION_RELEVANT_MISFIRES_TOTAL_C3
- Request
22 E0 0D - Service 22
DID E00D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 208 to 223 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2008 to 2022. Not supported for 2023 to 2024.
Emission relevant misfires total, cylinder 4 FORTE_EMIS_MIS_TOT_4Confirmed
- Request
22 E0 1D - Service 22
DID E01D - Module
7E0 → 7E8 - Every
1 s - Testing for 2008 to 2022
Example reply from a 2024 Kia Forte.
Bits 80 to 95 of the reply, 16 bits. The bytes are in little-endian order.
0x0000 = 0 → 0
- Formula
val- Range
- 0 to 65535
- Unit
- Number
Confirmed for 2023 to 2024. In testing for 2008 to 2022.
Emission relevant misfires total, cylinder 4 FORTE_EMISSION_RELEVANT_MISFIRES_TOTAL_C4
- Request
22 E0 0D - Service 22
DID E00D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 224 to 239 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2008 to 2022. Not supported for 2023 to 2024.
Emission relevant misfires, cylinder 1 FORTE_EMIS_MIS_1
- Request
21 08 - Service 21
PID 08 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 128 to 143 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2008 to 2022. Not supported for 2023 to 2024.
Emission relevant misfires, cylinder 2 FORTE_EMIS_MIS_2
- Request
21 08 - Service 21
PID 08 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 144 to 159 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2008 to 2022. Not supported for 2023 to 2024.
Emission relevant misfires, cylinder 3 FORTE_EMIS_MIS_3
- Request
21 08 - Service 21
PID 08 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 160 to 175 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2008 to 2022. Not supported for 2023 to 2024.
Emission relevant misfires, cylinder 4 FORTE_EMIS_MIS_4
- Request
21 08 - Service 21
PID 08 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 176 to 191 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2008 to 2022. Not supported for 2023 to 2024.
Emission relevant misfires, cylinder 5 FORTE_EMIS_MIS_5
- Request
21 08 - Service 21
PID 08 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 192 to 207 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2008 to 2022. Not supported for 2023 to 2024.
Emission relevant misfires, cylinder 6 FORTE_EMIS_MIS_6
- Request
21 08 - Service 21
PID 08 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 208 to 223 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2008 to 2022. Not supported for 2023 to 2024.
Engine coolant temperature ECTSAE J1979Confirmed
Your engine temperature must operate within a certain temperature range to operate efficiently and safely. If it runs too hot, then your engine could be permanently damaged. If it runs too cold, then your engine will use more fuel than necessary.
Pelican can show this parameter as the engine coolant temperature.
- Request
01 05 - Service 01
PID 05 - Module
7E0 → 7E8 - Every
500 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2013 to 2014, 2017 to 2020, 2022 to 2024. Supported for 2010 to 2012, 2016, 2021.
Engine Friction - Percent Torque TQ_FRSAE J1979Confirmed
- Request
01 8E - Service 01
PID 8E - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 125)- Range
- -125 to 130 %
- Unit
- %
Confirmed for 2022 to 2023. Supported for 2019.
Engine oil temperature FORTE_EOTConfirmed
Pelican can show this parameter as the engine oil temperature.
- Request
22 E0 01 - Service 22
DID E001 - Module
7E0 → 7E8 - Every
1 s - Testing for 2008 to 2016
Example reply from a 2024 Kia Forte.
Bits 272 to 279 of the reply, 8 bits.
0x9C = 156 → (156 ÷ 1.3333 − 48) = 69.002925 °C
- Formula
(val ÷ 1.3333 − 48)- Range
- 0 to 143.2547 °C
- Unit
- °C
Confirmed for 2017 to 2024. In testing for 2008 to 2009, 2011 to 2012, 2015. Not supported for 2010, 2013 to 2014, 2016.
Engine oil temperature FORTE_EOT_7E0
Pelican can show this parameter as the engine oil temperature.
- Request
22 ED 07 - Service 22
DID ED07 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 152 to 159 of the reply, 8 bits.
- Formula
(val × 0.7843 − 50)- Range
- -50 to 149.9965 °C
- Unit
- °C
In testing for 2008 to 2022. Not supported for 2023 to 2024.
Engine reference torque TQ_REFSAE J1979Confirmed
- Request
01 63 - Service 01
PID 63 - Module
7E0 → 7E8 - Every
86400 s
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 N·m
- Unit
- N·m
Confirmed for 2022 to 2023. Supported for 2019.
Engine RPM RPMSAE J1979Confirmed
- Request
01 0C - Service 01
PID 0C - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4)- Range
- 0 to 16383.75 rpm
- Unit
- rpm
Confirmed for 2017, 2022 to 2024. Supported for 2010 to 2014, 2016, 2018 to 2021.
Engine run time, total FORTE_ENG_RUN_TIME_TOT
- Request
21 0E - Service 21
PID 0E - Module
7E0 → 7E8 - Every
30 s - Testing
Bits 80 to 95 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val × 6)- Range
- 0 to 393209.9999 min
- Unit
- min
In testing for 2008 to 2022. Not supported for 2023 to 2024.
Engine, actual torque FORTE_ENG_ACT_TQ
- Request
22 ED 01 - Service 22
DID ED01 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 240 to 247 of the reply, 8 bits.
- Formula
(val × 2.3529)- Range
- 0 to 599.9895 N·m
- Unit
- N·m
In testing for 2008 to 2022. Not supported for 2023 to 2024.
Evap system vapor pressure EVAP_VPSAE J1979Confirmed
The pressure signal is normally obtained from a sensor located in the fuel tank or a sensor in an evaporative system vapor line.
- Request
01 32 - Service 01
PID 32 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 4000)- Range
- -8192 to 8191.75 kPa
- Unit
- kPa
Confirmed for 2017, 2022 to 2023. Supported for 2010 to 2014, 2016, 2018 to 2021, 2024.
Exhaust camshaft position FORTE_EXH_CAM_POSConfirmed
- Request
22 E0 20 - Service 22
DID E020 - Module
7E0 → 7E8 - Every
1 s - Testing for 2008 to 2022
Example reply from a 2024 Kia Forte.
Bits 88 to 103 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
0xC690 = -14704 → (-14704 ÷ 128) = -114.875 °
- Formula
(val ÷ 128)- Range
- -256 to 255 °
- Unit
- °
Confirmed for 2023 to 2024. In testing for 2008 to 2022.
Exhaust gas temperature FORTE_EXHAUST_GAS_T
- Request
21 03 - Service 21
PID 03 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 368 to 375 of the reply, 8 bits.
- Formula
(val × 4.709803922 + 99)- Range
- 99 to 1300 °C
- Unit
- °C
In testing for 2008 to 2022. Not supported for 2023 to 2024.
Exhaust temperature 1, upstream of oxidation catalyst FORTE_EXH_T_1_UP_OXICAT
- Request
22 ED 03 - Service 22
DID ED03 - Module
7E0 → 7E8 - Every
30 s - Testing
Bits 296 to 303 of the reply, 8 bits.
- Formula
(val × 4.7098 + 99)- Range
- 0 to 1299.999 °C
- Unit
- °C
In testing for 2008 to 2022. Not supported for 2023 to 2024.
Exhaust temperature 2, upstream of DPF FORTE_EXH_T_2_UP_DPF
- Request
22 ED 03 - Service 22
DID ED03 - Module
7E0 → 7E8 - Every
30 s - Testing
Bits 304 to 311 of the reply, 8 bits.
- Formula
(val × 4.7098 + 99)- Range
- 0 to 1299.999 °C
- Unit
- °C
In testing for 2008 to 2022. Not supported for 2023 to 2024.
Fuel rail pressure FRPSAE J1979Confirmed
Fuel rail pressure at the engine when the reading is referenced to atmosphere (gage pressure).
- Request
01 23 - Service 01
PID 23 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 10)- Range
- 0 to 655350 kPa
- Unit
- kPa
Confirmed for 2017, 2022 to 2023. Supported for 2014, 2021, 2024.
Gasoline direct injection time bank a, 1 FORTE_GDI_IT_A1
- Request
22 E0 05 - Service 22
DID E005 - Module
7E0 → 7E8 - Every
2 s - Testing for 2008 to 2022
Bits 224 to 239 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 ms
- Unit
- ms
In testing for 2008 to 2022. Supported for 2023 to 2024.
Gasoline direct injection time bank a, 2 FORTE_GDI_IT_A2
- Request
22 E0 05 - Service 22
DID E005 - Module
7E0 → 7E8 - Every
2 s - Testing for 2008 to 2022
Bits 240 to 255 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 ms
- Unit
- ms
In testing for 2008 to 2022. Supported for 2023 to 2024.
Gasoline direct injection time bank a, 3 FORTE_GDI_IT_A3
- Request
22 E0 05 - Service 22
DID E005 - Module
7E0 → 7E8 - Every
2 s - Testing for 2008 to 2022
Bits 256 to 271 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 ms
- Unit
- ms
In testing for 2008 to 2022. Supported for 2023 to 2024.
Gasoline direct injection time bank a, 4 FORTE_GDI_IT_A4
- Request
22 E0 05 - Service 22
DID E005 - Module
7E0 → 7E8 - Every
2 s - Testing for 2008 to 2022
Bits 272 to 287 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 ms
- Unit
- ms
In testing for 2008 to 2022. Supported for 2023 to 2024.
Gasoline direct injection time bank b, 1 FORTE_GDI_IT_B1
- Request
22 E0 05 - Service 22
DID E005 - Module
7E0 → 7E8 - Every
2 s - Testing for 2008 to 2022
Bits 352 to 367 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 ms
- Unit
- ms
In testing for 2008 to 2022. Supported for 2023 to 2024.
Gasoline direct injection time bank b, 2 FORTE_GDI_IT_B2
- Request
22 E0 05 - Service 22
DID E005 - Module
7E0 → 7E8 - Every
2 s - Testing for 2008 to 2022
Bits 368 to 383 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 ms
- Unit
- ms
In testing for 2008 to 2022. Supported for 2023 to 2024.
Gasoline direct injection time bank b, 3 FORTE_GDI_IT_B3
- Request
22 E0 05 - Service 22
DID E005 - Module
7E0 → 7E8 - Every
2 s - Testing for 2008 to 2022
Bits 384 to 399 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 ms
- Unit
- ms
In testing for 2008 to 2022. Supported for 2023 to 2024.
Gasoline direct injection time bank b, 4 FORTE_GDI_IT_B4
- Request
22 E0 05 - Service 22
DID E005 - Module
7E0 → 7E8 - Every
2 s - Testing for 2008 to 2022
Bits 400 to 415 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 ms
- Unit
- ms
In testing for 2008 to 2022. Supported for 2023 to 2024.
Idle control mode FORTE_IDLE_CONTROL_MODE
- Request
21 00 - Service 21
PID 00 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 120 to 127 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2008 to 2022. Not supported for 2023 to 2024.
Ignition retard due to knock control 1 FORTE_IGN_RETARD_KNOCK_1
- Request
21 19 - Service 21
PID 19 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 104 to 111 of the reply, 8 bits.
- Formula
(val × 0.75 − 191.25)- Range
- -191.25 to 0 °
- Unit
- °
In testing for 2008 to 2022. Not supported for 2023 to 2024.
Ignition retard due to knock control 2 FORTE_IGN_RETARD_KNOCK_2
- Request
21 19 - Service 21
PID 19 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 112 to 119 of the reply, 8 bits.
- Formula
(val × 0.75 − 191.25)- Range
- -191.25 to 0 °
- Unit
- °
In testing for 2008 to 2022. Not supported for 2023 to 2024.
Ignition retard due to knock control 3 FORTE_IGN_RETARD_KNOCK_3
- Request
21 19 - Service 21
PID 19 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 120 to 127 of the reply, 8 bits.
- Formula
(val × 0.75 − 191.25)- Range
- -191.25 to 0 °
- Unit
- °
In testing for 2008 to 2022. Not supported for 2023 to 2024.
Ignition retard due to knock control 4 FORTE_IGN_RETARD_KNOCK_4
- Request
21 19 - Service 21
PID 19 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 128 to 135 of the reply, 8 bits.
- Formula
(val × 0.75 − 191.25)- Range
- -191.25 to 0 °
- Unit
- °
In testing for 2008 to 2022. Not supported for 2023 to 2024.
Injection duration cylinder 1 FORTE_INJ_DUR_1Confirmed
- Request
22 E0 02 - Service 22
DID E002 - Module
7E0 → 7E8 - Every
5 s - Testing for 2008 to 2016
Bits 176 to 191 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val ÷ 1220.7)- Range
- 0 to 53.6864 s
- Unit
- s
Confirmed for 2017 to 2024. In testing for 2008 to 2009, 2011 to 2012, 2015. Not supported for 2010, 2013 to 2014, 2016.
Injection duration cylinder 2 FORTE_INJ_DUR_2Confirmed
- Request
22 E0 02 - Service 22
DID E002 - Module
7E0 → 7E8 - Every
5 s - Testing for 2008 to 2016
Bits 192 to 207 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val ÷ 1220.7)- Range
- 0 to 53.6864 s
- Unit
- s
Confirmed for 2017 to 2024. In testing for 2008 to 2009, 2011 to 2012, 2015. Not supported for 2010, 2013 to 2014, 2016.
Injection duration cylinder 3 FORTE_INJ_DUR_3Confirmed
- Request
22 E0 02 - Service 22
DID E002 - Module
7E0 → 7E8 - Every
5 s - Testing for 2008 to 2016
Bits 208 to 223 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val ÷ 1220.7)- Range
- 0 to 53.6864 s
- Unit
- s
Confirmed for 2017 to 2024. In testing for 2008 to 2009, 2011 to 2012, 2015. Not supported for 2010, 2013 to 2014, 2016.
Injection duration cylinder 4 FORTE_INJ_DUR_4Confirmed
- Request
22 E0 02 - Service 22
DID E002 - Module
7E0 → 7E8 - Every
5 s - Testing for 2008 to 2016
Bits 224 to 239 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val ÷ 1220.7)- Range
- 0 to 53.6864 s
- Unit
- s
Confirmed for 2017 to 2024. In testing for 2008 to 2009, 2011 to 2012, 2015. Not supported for 2010, 2013 to 2014, 2016.
Intake air temperature FORTE_IATConfirmed
- Request
22 E0 01 - Service 22
DID E001 - Module
7E0 → 7E8 - Every
1 s - Testing for 2008 to 2016
Example reply from a 2024 Kia Forte.
Bits 264 to 271 of the reply, 8 bits.
0x7C = 124 → (124 ÷ 1.3333 − 48) = 45.002325 °C
- Formula
(val ÷ 1.3333 − 48)- Range
- 0 to 143.2547 °C
- Unit
- °C
Confirmed for 2017 to 2024. In testing for 2008 to 2009, 2011 to 2012, 2015. Not supported for 2010, 2013 to 2014, 2016.
Intake air temperature IATSAE J1979Confirmed
- Request
01 0F - Service 01
PID 0F - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2017, 2022 to 2023. Supported for 2010 to 2014, 2016, 2018 to 2021, 2024.
Intake camshaft position FORTE_INT_CAM_POSConfirmed
- Request
22 E0 20 - Service 22
DID E020 - Module
7E0 → 7E8 - Every
1 s - Testing for 2008 to 2022
Example reply from a 2024 Kia Forte.
Bits 72 to 87 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
0x4020 = 16416 → (16416 ÷ 128) = 128.25 °
- Formula
(val ÷ 128)- Range
- -256 to 255 °
- Unit
- °
Confirmed for 2023 to 2024. In testing for 2008 to 2022.
Intake camshaft position actual FORTE_INTAKE_CAMSHAFT_POSITION_ACTUAL
- Request
21 17 - Service 21
PID 17 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 40 to 55 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
(val ÷ 128)- Range
- -256 to 255 °
- Unit
- °
In testing for 2008 to 2022. Not supported for 2023 to 2024.
Intake camshaft position commanded FORTE_INTAKE_CAMSHAFT_POSITION_COMMANDED
- Request
21 17 - Service 21
PID 17 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 32 to 39 of the reply, 8 bits. The value is signed.
- Formula
(val ÷ 2)- Range
- -64 to 63.5 °
- Unit
- °
In testing for 2008 to 2022. Not supported for 2023 to 2024.
Intake manifold absolute pressure MAPSAE J1979Confirmed
- Request
01 0B - Service 01
PID 0B - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 kPa
- Unit
- kPa
Confirmed for 2017, 2022 to 2023. Supported for 2010 to 2014, 2016, 2018 to 2021, 2024.
Inverter temperature FORTE_HVAC_INVERTER_TConfirmed
- Request
22 01 02 - Service 22
DID 0102 - Module
7B3 → 7BB - Every
1 s - Testing for 2008 to 2022
Example reply from a 2024 Kia Forte.
Bits 96 to 103 of the reply, 8 bits.
0xFF = 255 → (255 ÷ 2 − 40) = 87.5 °C
- Formula
(val ÷ 2 − 40)- Range
- -40 to 87.5 °C
- Unit
- °C
Confirmed for 2023 to 2024. In testing for 2008 to 2022.
Knock detected FORTE_KNOCK_DETECTED
- Request
21 00 - Service 21
PID 00 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 200 to 207 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2008 to 2022. Not supported for 2023 to 2024.
Knock learn cylinder 1 FORTE_KNOCK_LEARN_1Confirmed
- Request
22 E0 0A - Service 22
DID E00A - Module
7E0 → 7E8 - Every
1 s - Testing for 2008 to 2016
Example reply from a 2024 Kia Forte.
Bits 160 to 167 of the reply, 8 bits. The value is signed.
0x00 = 0 → (0 ÷ 5) = 0 °
- Formula
(val ÷ 5)- Range
- -25.6 to 25.4 °
- Unit
- °
Confirmed for 2021 to 2024. In testing for 2008 to 2009, 2011 to 2012, 2015. Supported for 2017 to 2020. Not supported for 2010, 2013 to 2014, 2016.
Knock learn cylinder 2 FORTE_KNOCK_LEARN_2Confirmed
- Request
22 E0 0A - Service 22
DID E00A - Module
7E0 → 7E8 - Every
1 s - Testing for 2008 to 2016
Example reply from a 2024 Kia Forte.
Bits 168 to 175 of the reply, 8 bits. The value is signed.
0xFC = -4 → (-4 ÷ 5) = -0.8 °
- Formula
(val ÷ 5)- Range
- -25.6 to 25.4 °
- Unit
- °
Confirmed for 2021 to 2024. In testing for 2008 to 2009, 2011 to 2012, 2015. Supported for 2017 to 2020. Not supported for 2010, 2013 to 2014, 2016.
Knock learn cylinder 3 FORTE_KNOCK_LEARN_3Confirmed
- Request
22 E0 0A - Service 22
DID E00A - Module
7E0 → 7E8 - Every
1 s - Testing for 2008 to 2016
Example reply from a 2024 Kia Forte.
Bits 176 to 183 of the reply, 8 bits. The value is signed.
0x00 = 0 → (0 ÷ 5) = 0 °
- Formula
(val ÷ 5)- Range
- -25.6 to 25.4 °
- Unit
- °
Confirmed for 2021 to 2024. In testing for 2008 to 2009, 2011 to 2012, 2015. Supported for 2017 to 2020. Not supported for 2010, 2013 to 2014, 2016.
Knock learn cylinder 4 FORTE_KNOCK_LEARN_4Confirmed
- Request
22 E0 0A - Service 22
DID E00A - Module
7E0 → 7E8 - Every
1 s - Testing for 2008 to 2016
Example reply from a 2024 Kia Forte.
Bits 184 to 191 of the reply, 8 bits. The value is signed.
0xFC = -4 → (-4 ÷ 5) = -0.8 °
- Formula
(val ÷ 5)- Range
- -25.6 to 25.4 °
- Unit
- °
Confirmed for 2021 to 2024. In testing for 2008 to 2009, 2011 to 2012, 2015. Supported for 2017 to 2020. Not supported for 2010, 2013 to 2014, 2016.
Knock retard cylinder #1 FORTE_KNOCK_RETARD_CYLINDER_1
- Request
21 16 - Service 21
PID 16 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 96 to 103 of the reply, 8 bits.
- Formula
(val × 0.75)- Range
- 0 to 191.25 °
- Unit
- °
In testing for 2008 to 2022. Not supported for 2023 to 2024.
Knock retard cylinder #2 FORTE_KNOCK_RETARD_CYLINDER_2
- Request
21 16 - Service 21
PID 16 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 104 to 111 of the reply, 8 bits.
- Formula
(val × 0.75)- Range
- 0 to 191.25 °
- Unit
- °
In testing for 2008 to 2022. Not supported for 2023 to 2024.
Knock retard cylinder #3 FORTE_KNOCK_RETARD_CYLINDER_3
- Request
21 16 - Service 21
PID 16 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 112 to 119 of the reply, 8 bits.
- Formula
(val × 0.75)- Range
- 0 to 191.25 °
- Unit
- °
In testing for 2008 to 2022. Not supported for 2023 to 2024.
Knock retard cylinder #4 FORTE_KNOCK_RETARD_CYLINDER_4
- Request
21 16 - Service 21
PID 16 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 120 to 127 of the reply, 8 bits.
- Formula
(val × 0.75)- Range
- 0 to 191.25 °
- Unit
- °
In testing for 2008 to 2022. Not supported for 2023 to 2024.
Knock retard cylinder 1 FORTE_KNOCK_RETARD_1Confirmed
- Request
22 E0 0A - Service 22
DID E00A - Module
7E0 → 7E8 - Every
1 s - Testing for 2008 to 2016
Example reply from a 2024 Kia Forte.
Bits 96 to 103 of the reply, 8 bits. The value is signed.
0xA7 = -89 → (-89 ÷ 5) = -17.8 °
- Formula
(val ÷ 5)- Range
- -25.6 to 25.4 °
- Unit
- °
Confirmed for 2017 to 2024. In testing for 2008 to 2009, 2011 to 2012, 2015. Not supported for 2010, 2013 to 2014, 2016.
Knock retard cylinder 1 FORTE_KNOCK_RETARD_CYL_1
- Request
21 19 - Service 21
PID 19 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 168 to 175 of the reply, 8 bits.
- Formula
(val × 0.75 − 191.25)- Range
- -191.25 to 0 °
- Unit
- °
In testing for 2008 to 2022. Not supported for 2023 to 2024.
Knock retard cylinder 1, alternate FORTE_KNOCK_RETARD_1_E019Confirmed
- Request
22 E0 19 - Service 22
DID E019 - Module
7E0 → 7E8 - Every
1 s - Testing for 2008 to 2022
Example reply from a 2024 Kia Forte.
Bits 168 to 175 of the reply, 8 bits.
0xFF = 255 → (255 × 0.75 − 191.25) = 0 °
- Formula
(val × 0.75 − 191.25)- Range
- -191.25 to 0 °
- Unit
- °
Confirmed for 2023 to 2024. In testing for 2008 to 2022.
Knock retard cylinder 1, alternate FORTE_KNOCK_RETARD_CYL_1_ALT
- Request
21 0A - Service 21
PID 0A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 160 to 167 of the reply, 8 bits.
- Formula
(val ÷ 1.333333333)- Range
- 0 to 191.25 °
- Unit
- °
In testing for 2008 to 2022. Not supported for 2023 to 2024.
Knock retard cylinder 2 FORTE_KNOCK_RETARD_2Confirmed
- Request
22 E0 0A - Service 22
DID E00A - Module
7E0 → 7E8 - Every
1 s - Testing for 2008 to 2016
Example reply from a 2024 Kia Forte.
Bits 104 to 111 of the reply, 8 bits. The value is signed.
0x20 = 32 → (32 ÷ 5) = 6.4 °
- Formula
(val ÷ 5)- Range
- -25.6 to 25.4 °
- Unit
- °
Confirmed for 2017 to 2024. In testing for 2008 to 2009, 2011 to 2012, 2015. Not supported for 2010, 2013 to 2014, 2016.
Knock retard cylinder 2 FORTE_KNOCK_RETARD_CYL_2
- Request
21 19 - Service 21
PID 19 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 176 to 183 of the reply, 8 bits.
- Formula
(val × 0.75 − 191.25)- Range
- -191.25 to 0 °
- Unit
- °
In testing for 2008 to 2022. Not supported for 2023 to 2024.
Knock retard cylinder 2, alternate FORTE_KNOCK_RETARD_2_E019Confirmed
- Request
22 E0 19 - Service 22
DID E019 - Module
7E0 → 7E8 - Every
1 s - Testing for 2008 to 2022
Example reply from a 2024 Kia Forte.
Bits 176 to 183 of the reply, 8 bits.
0xFF = 255 → (255 × 0.75 − 191.25) = 0 °
- Formula
(val × 0.75 − 191.25)- Range
- -191.25 to 0 °
- Unit
- °
Confirmed for 2023 to 2024. In testing for 2008 to 2022.
Knock retard cylinder 2, alternate FORTE_KNOCK_RETARD_CYL_2_ALT
- Request
21 0A - Service 21
PID 0A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 168 to 175 of the reply, 8 bits.
- Formula
(val ÷ 1.333333333)- Range
- 0 to 191.25 °
- Unit
- °
In testing for 2008 to 2022. Not supported for 2023 to 2024.
Knock retard cylinder 3 FORTE_KNOCK_RETARD_3Confirmed
- Request
22 E0 0A - Service 22
DID E00A - Module
7E0 → 7E8 - Every
1 s - Testing for 2008 to 2016
Example reply from a 2024 Kia Forte.
Bits 112 to 119 of the reply, 8 bits. The value is signed.
0x9E = -98 → (-98 ÷ 5) = -19.6 °
- Formula
(val ÷ 5)- Range
- -25.6 to 25.4 °
- Unit
- °
Confirmed for 2017 to 2024. In testing for 2008 to 2009, 2011 to 2012, 2015. Not supported for 2010, 2013 to 2014, 2016.
Knock retard cylinder 3 FORTE_KNOCK_RETARD_CYL_3
- Request
21 19 - Service 21
PID 19 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 184 to 191 of the reply, 8 bits.
- Formula
(val × 0.75 − 191.25)- Range
- -191.25 to 0 °
- Unit
- °
In testing for 2008 to 2022. Not supported for 2023 to 2024.
Knock retard cylinder 3, alternate FORTE_KNOCK_RETARD_3_E019Confirmed
- Request
22 E0 19 - Service 22
DID E019 - Module
7E0 → 7E8 - Every
1 s - Testing for 2008 to 2022
Example reply from a 2024 Kia Forte.
Bits 184 to 191 of the reply, 8 bits.
0xFF = 255 → (255 × 0.75 − 191.25) = 0 °
- Formula
(val × 0.75 − 191.25)- Range
- -191.25 to 0 °
- Unit
- °
Confirmed for 2023 to 2024. In testing for 2008 to 2022.
Knock retard cylinder 3, alternate FORTE_KNOCK_RETARD_CYL_3_ALT
- Request
21 0A - Service 21
PID 0A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 176 to 183 of the reply, 8 bits.
- Formula
(val ÷ 1.333333333)- Range
- 0 to 191.25 °
- Unit
- °
In testing for 2008 to 2022. Not supported for 2023 to 2024.
Knock retard cylinder 4 FORTE_KNOCK_RETARD_4Confirmed
- Request
22 E0 0A - Service 22
DID E00A - Module
7E0 → 7E8 - Every
1 s - Testing for 2008 to 2016
Example reply from a 2024 Kia Forte.
Bits 120 to 127 of the reply, 8 bits. The value is signed.
0x78 = 120 → (120 ÷ 5) = 24 °
- Formula
(val ÷ 5)- Range
- -25.6 to 25.4 °
- Unit
- °
Confirmed for 2017 to 2024. In testing for 2008 to 2009, 2011 to 2012, 2015. Not supported for 2010, 2013 to 2014, 2016.
Knock retard cylinder 4 FORTE_KNOCK_RETARD_CYL_4
- Request
21 19 - Service 21
PID 19 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 192 to 199 of the reply, 8 bits.
- Formula
(val × 0.75 − 191.25)- Range
- -191.25 to 0 °
- Unit
- °
In testing for 2008 to 2022. Not supported for 2023 to 2024.
Knock retard cylinder 4, alternate FORTE_KNOCK_RETARD_4_E019Confirmed
- Request
22 E0 19 - Service 22
DID E019 - Module
7E0 → 7E8 - Every
1 s - Testing for 2008 to 2022
Example reply from a 2024 Kia Forte.
Bits 192 to 199 of the reply, 8 bits.
0xFF = 255 → (255 × 0.75 − 191.25) = 0 °
- Formula
(val × 0.75 − 191.25)- Range
- -191.25 to 0 °
- Unit
- °
Confirmed for 2023 to 2024. In testing for 2008 to 2022.
Knock retard cylinder 4, alternate FORTE_KNOCK_RETARD_CYL_4_ALT
- Request
21 0A - Service 21
PID 0A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 184 to 191 of the reply, 8 bits.
- Formula
(val ÷ 1.333333333)- Range
- 0 to 191.25 °
- Unit
- °
In testing for 2008 to 2022. Not supported for 2023 to 2024.
Long term fuel trim (bank 1) LONGFT1SAE J1979Confirmed
- Request
01 07 - Service 01
PID 07 - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 128 − 100)- Range
- -100 to 99.2 %
- Unit
- %
Confirmed for 2017, 2022 to 2023. Supported for 2010 to 2014, 2016, 2018 to 2021, 2024.
Long term secondary O2 sensor fuel trim (bank 1) LGSO2FT1SAE J1979Confirmed
- Request
01 56 - Service 01
PID 56 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 128 − 100)- Range
- -100 to 99.22 %
- Unit
- %
Confirmed for 2017, 2022 to 2023. Supported for 2019.
Main injection volume FORTE_MAIN_INJECTION_QTY
- Request
21 07 - Service 21
PID 07 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 96 to 103 of the reply, 8 bits.
- Formula
(val × 0.392156863)- Range
- 0 to 100 L
- Unit
- L
In testing for 2008 to 2022. Not supported for 2023 to 2024.
Mass air flow rate FORTE_MAF_RATEConfirmed
- Request
22 E0 10 - Service 22
DID E010 - Module
7E0 → 7E8 - Every
1 s - Testing for 2008 to 2022
Example reply from a 2024 Kia Forte.
Bits 208 to 215 of the reply, 8 bits. The bytes are in little-endian order.
0xAE = 174 → (174 × 0.04239) = 7.37586
- Formula
(val × 0.04239)- Range
- 0 to 10.8
- Unit
- Raw value
Confirmed for 2023 to 2024. In testing for 2008 to 2022.
Max adaptation value for lower mechanical stop of the boost pressure actuator during engine running FORTE_MAX_ADPT_LO_MECH_STOP_P
- Request
21 19 - Service 21
PID 19 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 480 to 495 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val × 1.53 ÷ 10000)- Range
- 0 to 10.02 V
- Unit
- V
In testing for 2008 to 2022. Not supported for 2023 to 2024.
Max adaptation value for lower mechanical stop of the boost pressure actuator during engine stop FORTE_MAX_ADPT_LO_MECH_P
- Request
21 19 - Service 21
PID 19 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 464 to 479 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val × 1.53 ÷ 10000)- Range
- 0 to 10.02 V
- Unit
- V
In testing for 2008 to 2022. Not supported for 2023 to 2024.
Min adaptation value for lower mechanical stop of the boost pressure actuator during engine running FORTE_MIN_ADPT_LO_MECH_STOP_P
- Request
21 19 - Service 21
PID 19 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 512 to 527 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val × 1.53 ÷ 10000)- Range
- 0 to 10.02 V
- Unit
- V
In testing for 2008 to 2022. Not supported for 2023 to 2024.
Min adaptation value for lower mechanical stop of the boost pressure actuator during engine stop FORTE_MIN_ADPT_LO_MECH_P
- Request
21 19 - Service 21
PID 19 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 496 to 511 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val × 1.53 ÷ 10000)- Range
- 0 to 10.02 V
- Unit
- V
In testing for 2008 to 2022. Not supported for 2023 to 2024.
Misfire count #1 FORTE_MIS_1Confirmed
- Request
21 01 - Service 21
PID 01 - Module
7E0 → 7E8 - Every
1 s - Testing for 2008 to 2009, 2011 to 2012, 2015, 2018 to 2024
Example reply from a 2017 Kia Forte.
Bits 56 to 71 of the reply, 16 bits. The bytes are in little-endian order.
0x15B0 = 5552 → 5,552
- Formula
val- Range
- 0 to 65535
- Unit
- Number
Confirmed for 2010, 2013 to 2014, 2016 to 2017. In testing for 2008 to 2009, 2011 to 2012, 2015. Not supported for 2018 to 2024.
Misfire count #2 FORTE_MIS_2Confirmed
- Request
21 01 - Service 21
PID 01 - Module
7E0 → 7E8 - Every
1 s - Testing for 2008 to 2009, 2011 to 2012, 2015, 2018 to 2024
Example reply from a 2017 Kia Forte.
Bits 72 to 87 of the reply, 16 bits. The bytes are in little-endian order.
0x0059 = 89 → 89
- Formula
val- Range
- 0 to 65535
- Unit
- Number
Confirmed for 2010, 2013 to 2014, 2016 to 2017. In testing for 2008 to 2009, 2011 to 2012, 2015. Not supported for 2018 to 2024.
Misfire count #3 FORTE_MIS_3Confirmed
- Request
21 01 - Service 21
PID 01 - Module
7E0 → 7E8 - Every
1 s - Testing for 2008 to 2009, 2011 to 2012, 2015, 2018 to 2024
Example reply from a 2017 Kia Forte.
Bits 88 to 103 of the reply, 16 bits. The bytes are in little-endian order.
0x0000 = 0 → 0
- Formula
val- Range
- 0 to 65535
- Unit
- Number
Confirmed for 2010, 2013 to 2014, 2016 to 2017. In testing for 2008 to 2009, 2011 to 2012, 2015. Not supported for 2018 to 2024.
Misfire count #4 FORTE_MIS_4Confirmed
- Request
21 01 - Service 21
PID 01 - Module
7E0 → 7E8 - Every
1 s - Testing for 2008 to 2009, 2011 to 2012, 2015, 2018 to 2024
Example reply from a 2017 Kia Forte.
Bits 104 to 119 of the reply, 16 bits. The bytes are in little-endian order.
0x2700 = 9984 → 9,984
- Formula
val- Range
- 0 to 65535
- Unit
- Number
Confirmed for 2010, 2013 to 2014, 2016 to 2017. In testing for 2008 to 2009, 2011 to 2012, 2015. Not supported for 2018 to 2024.
Misfires current total FORTE_MIS_CURRENT_TOT
- Request
21 08 - Service 21
PID 08 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 584 to 591 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2008 to 2022. Not supported for 2023 to 2024.
Misfires current, cylinder 1 FORTE_MIS_CURRENT_1
- Request
21 08 - Service 21
PID 08 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 536 to 543 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2008 to 2022. Not supported for 2023 to 2024.
Misfires current, cylinder 2 FORTE_MIS_CURRENT_2
- Request
21 08 - Service 21
PID 08 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 544 to 551 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2008 to 2022. Not supported for 2023 to 2024.
Misfires current, cylinder 3 FORTE_MIS_CURRENT_3
- Request
21 08 - Service 21
PID 08 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 552 to 559 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2008 to 2022. Not supported for 2023 to 2024.
Misfires current, cylinder 4 FORTE_MIS_CURRENT_4
- Request
21 08 - Service 21
PID 08 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 560 to 567 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2008 to 2022. Not supported for 2023 to 2024.
Misfires current, cylinder 5 FORTE_MIS_CURRENT_5
- Request
21 08 - Service 21
PID 08 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 568 to 575 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2008 to 2022. Not supported for 2023 to 2024.
Misfires current, cylinder 6 FORTE_MIS_CURRENT_6
- Request
21 08 - Service 21
PID 08 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 576 to 583 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2008 to 2022. Not supported for 2023 to 2024.
Misfires, current, cylinder 1 FORTE_MISFIRES_C1_CUR
- Request
22 E0 0D - Service 22
DID E00D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 48 to 63 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2008 to 2022. Not supported for 2023 to 2024.
Misfires, current, cylinder 2 FORTE_MISFIRES_C2_CUR
- Request
22 E0 0D - Service 22
DID E00D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 64 to 79 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2008 to 2022. Not supported for 2023 to 2024.
Misfires, current, cylinder 3 FORTE_MISFIRES_C3_CUR
- Request
22 E0 0D - Service 22
DID E00D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 80 to 95 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2008 to 2022. Not supported for 2023 to 2024.
Misfires, current, cylinder 4 FORTE_MISFIRES_C4_CUR
- Request
22 E0 0D - Service 22
DID E00D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 96 to 111 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2008 to 2022. Not supported for 2023 to 2024.
Motor-driven power steering current FORTE_MDPS_MOTOR_CURRENTConfirmed
- Request
22 01 01 - Service 22
DID 0101 - Module
7D4 → 7DC - Every
5 s - Testing for 2008 to 2019, 2021 to 2022
Example reply from a 2024 Kia Forte.
Bits 88 to 95 of the reply, 8 bits. The value is signed.
0x00 = 0 → 0 A
- Formula
val- Range
- -128 to 127 A
- Unit
- A
Confirmed for 2020, 2023 to 2024. In testing for 2008 to 2012, 2014 to 2015, 2018 to 2019, 2021 to 2022. Not supported for 2013, 2016 to 2017.
Oxygen sensor 1 bank 1 FORTE_OXYGEN_SENSOR_11
- Request
21 02 - Service 21
PID 02 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val × 0.00521 − 0.2)- Range
- -0.2 to 1.12 V
- Unit
- V
In testing for 2008 to 2022. Not supported for 2023 to 2024.
Oxygen sensor 2 bank 1 FORTE_OXYGEN_SENSOR_21
- Request
21 02 - Service 21
PID 02 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 48 to 55 of the reply, 8 bits.
- Formula
(val × 0.00521 − 0.2)- Range
- -0.2 to 1.12 V
- Unit
- V
In testing for 2008 to 2022. Not supported for 2023 to 2024.
Pilot injection volume FORTE_PILOT_INJECTION_QTY
- Request
21 07 - Service 21
PID 07 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 104 to 119 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 L
- Unit
- L
In testing for 2008 to 2022. Not supported for 2023 to 2024.
Post injection volume FORTE_POST_INJECTION_QTY
- Request
21 07 - Service 21
PID 07 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 128 to 143 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 L
- Unit
- L
In testing for 2008 to 2022. Not supported for 2023 to 2024.
Requested torque FORTE_REQUESTED_TORQUE
- Request
21 14 - Service 21
PID 14 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 176 to 191 of the reply, 16 bits.
- Formula
(val × 0.001526)- Range
- 0 to 100 %
- Unit
- %
In testing for 2008 to 2022. Not supported for 2023 to 2024.
Requested torque limitation from traction control FORTE_REQ_TQ_LIM_TRACTION
- Request
22 ED 06 - Service 22
DID ED06 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 120 to 127 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
In testing for 2008 to 2022. Not supported for 2023 to 2024.
Short term fuel trim (bank 1) SHRTFT1SAE J1979Confirmed
Correction being used by the closed-loop fuel algorithm.
Pelican can show this parameter as the short term fuel trim.
- Request
01 06 - Service 01
PID 06 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 128 − 100)- Range
- -100 to 99.2 %
- Unit
- %
Confirmed for 2013 to 2014, 2017 to 2024. Supported for 2010 to 2012, 2016.
Short term secondary O2 sensor fuel trim (bank 1) STSO2FT1SAE J1979Confirmed
- Request
01 55 - Service 01
PID 55 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 128 − 100)- Range
- -100 to 99.22 %
- Unit
- %
Confirmed for 2022 to 2023. Supported for 2019.
Throttle position #1 FORTE_THROTTLE_POSITION__1
- Request
21 14 - Service 21
PID 14 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 48 to 63 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
(val × 0.0244140625)- Range
- -800 to 799 %
- Unit
- %
In testing for 2008 to 2022. Not supported for 2023 to 2024.
Throttle position #2 FORTE_THROTTLE_POSITION__2
- Request
21 14 - Service 21
PID 14 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 64 to 79 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
(val × 0.0244140625)- Range
- -800 to 799 %
- Unit
- %
In testing for 2008 to 2022. Not supported for 2023 to 2024.
Timing advance SPARKADVSAE J1979Confirmed
Ignition timing spark advance for the first cylinder. Measured in degrees before dead center. Minus is degrees before dead center, positive is degrees after.
- Request
01 0E - Service 01
PID 0E - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 2 − 64)- Range
- -64 to 63.5 °
- Unit
- °
Confirmed for 2017, 2022 to 2024. Supported for 2010 to 2014, 2016, 2018 to 2021.
Timing advance #1 FORTE_TIMING_ADVANCE_1
- Request
21 13 - Service 21
PID 13 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 32 to 39 of the reply, 8 bits. The value is signed.
- Formula
(val × 0.75)- Range
- -96 to 95.25 °
- Unit
- °
In testing for 2008 to 2022. Not supported for 2023 to 2024.
Timing advance #2 FORTE_TIMING_ADVANCE_2
- Request
21 13 - Service 21
PID 13 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 40 to 47 of the reply, 8 bits. The value is signed.
- Formula
(val × 0.75)- Range
- -96 to 95.25 °
- Unit
- °
In testing for 2008 to 2022. Not supported for 2023 to 2024.
Timing advance #3 FORTE_TIMING_ADVANCE_3
- Request
21 13 - Service 21
PID 13 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 48 to 55 of the reply, 8 bits. The value is signed.
- Formula
(val × 0.75)- Range
- -96 to 95.25 °
- Unit
- °
In testing for 2008 to 2022. Not supported for 2023 to 2024.
Timing advance #4 FORTE_TIMING_ADVANCE_4
- Request
21 13 - Service 21
PID 13 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 56 to 63 of the reply, 8 bits. The value is signed.
- Formula
(val × 0.75)- Range
- -96 to 95.25 °
- Unit
- °
In testing for 2008 to 2022. Not supported for 2023 to 2024.
Torque converter slip FORTE_TORQUE_CONVERTER_SLIPConfirmed
- Request
22 01 A0 - Service 22
DID 01A0 - Module
7E1 → 7E9 - Every
250 ms - Testing for 2008 to 2022
Example reply from a 2024 Kia Forte.
Bits 128 to 143 of the reply, 16 bits.
0x0840 = 2112 → (2112 ÷ 4 − 512) = 16 rpm
- Formula
(val ÷ 4 − 512)- Range
- -512 to 15871.75 rpm
- Unit
- rpm
Confirmed for 2023 to 2024. In testing for 2008 to 2022.
Torque converter slip FORTE_TQ_CONV_SLIP
- Request
21 A0 - Service 21
PID A0 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 104 to 119 of the reply, 16 bits.
- Formula
(val ÷ 4 − 512)- Range
- -512 to 15871.75 rpm
- Unit
- rpm
In testing for 2008 to 2022. Not supported for 2023 to 2024.
Transmission fluid temperature FORTE_ATF_T_7E0
Pelican can show this parameter as the transmission fluid temperature.
- Request
21 A0 - Service 21
PID A0 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 264 to 271 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2008 to 2022. Not supported for 2023 to 2024.
Turbo boost pressure FORTE_TURBO_BOOST_P
- Request
21 19 - Service 21
PID 19 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 64 to 79 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val × 829.1 ÷ 10000)- Range
- 0 to 5433
- Unit
- Raw value
In testing for 2008 to 2022. Not supported for 2023 to 2024.
Turbo boost pressure, gauge FORTE_TURBO_BOOSTConfirmed
- Request
22 E0 21 - Service 22
DID E021 - Module
7E0 → 7E8 - Every
100 ms - Testing for 2008 to 2016, 2021
Bits 56 to 71 of the reply, 16 bits.
- Formula
(val ÷ 831.556909 − 12)- Range
- -10 to 66.81 psi
- Unit
- psi
Confirmed for 2017 to 2020, 2022 to 2024. In testing for 2008 to 2009, 2011 to 2012, 2015. Not supported for 2010, 2013 to 2014, 2016, 2021.
Type of fuel currently being used by the vehicle FUEL_TYPSAE J1979Confirmed
- Request
01 51 - Service 01
PID 51 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
1 | GAS | Gasoline/petrol |
2 | METH | Methanol |
3 | ETH | Ethanol |
4 | DSL | Diesel |
5 | LPG | Liquefied petroleum gas |
6 | CNG | Compressed natural gas |
7 | PROP | Propane |
8 | ELEC | Battery/electric |
9 | BI_GAS | Bi-fuel vehicle using gasoline/petrol |
10 | BI_METH | Bi-fuel vehicle using methanol |
11 | BI_ETH | Bi-fuel vehicle using ethanol |
12 | BI_LPG | Bi-fuel vehicle using LPG |
13 | BI_CNG | Bi-fuel vehicle using CNG |
14 | BI_PROP | Bi-fuel vehicle using propane |
15 | BI_ELEC | Bi-fuel vehicle using battery |
16 | BI_MIX | Bi-fuel vehicle using battery and combustion engine for propulsion |
17 | HYB_GAS | Hybrid vehicle using gasoline engine for propulsion |
18 | HYB_ETH | Hybrid vehicle using gasoline engine on ethanol for propulsion |
19 | HYB_DSL | Hybrid vehicle using diesel engine for propulsion |
20 | HYB_ELEC | Hybrid vehicle using battery for propulsion |
21 | HYB_MIX | Hybrid vehicle using battery and combustion engine for propulsion |
22 | HYB_REG | Hybrid vehicle in regeneration mode |
23 | BI_DSL | Bi-fuel vehicle using diesel |
24 | BI_NG | Bi-fuel vehicle using natural gas |
25 | BI_DSL | Bi-fuel vehicle using diesel |
26 | NG | Natural gas |
27 | DSL_CNG | Dual fuel vehicle using diesel and CNG |
28 | DSL_LNG | Dual fuel vehicle using diesel and LNG |
29 | FC_H2 | Fuel cell utilizing hydrogen |
30 | HICE_HHO | Hydrogen Internal Combustion Engine |
31 | KERO | Kerosene |
32 | HFO | Heavy Fuel Oil |
Confirmed for 2017, 2022 to 2023. Supported for 2019.
Waste gate duty FORTE_WG_DUTYConfirmed
- Request
22 E0 21 - Service 22
DID E021 - Module
7E0 → 7E8 - Every
100 ms - Testing for 2008 to 2016, 2021
Bits 408 to 423 of the reply, 16 bits.
- Formula
(val × 200 ÷ 65535)- Range
- 0 to 200 %
- Unit
- %
Confirmed for 2017 to 2020, 2022 to 2024. In testing for 2008 to 2009, 2011 to 2012, 2015. Not supported for 2010, 2013 to 2014, 2016, 2021.
Waste gate position FORTE_WG_POSITIONConfirmed
- Request
22 E0 21 - Service 22
DID E021 - Module
7E0 → 7E8 - Every
100 ms - Testing for 2008 to 2016, 2021
Bits 424 to 439 of the reply, 16 bits.
- Formula
(val × 400 ÷ 65535)- Range
- 0 to 400 %
- Unit
- %
Confirmed for 2017 to 2020, 2022 to 2024. In testing for 2008 to 2009, 2011 to 2012, 2015. Not supported for 2010, 2013 to 2014, 2016, 2021.
Waste gate set point FORTE_WG_SETPOINTConfirmed
- Request
22 E0 21 - Service 22
DID E021 - Module
7E0 → 7E8 - Every
100 ms - Testing for 2008 to 2016, 2021
Bits 440 to 455 of the reply, 16 bits.
- Formula
(val × 400 ÷ 65535)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2017 to 2020, 2022 to 2024. In testing for 2008 to 2009, 2011 to 2012, 2015. Not supported for 2010, 2013 to 2014, 2016, 2021.
Waste gate voltage FORTE_WG_VOLTAGEConfirmed
- Request
22 E0 21 - Service 22
DID E021 - Module
7E0 → 7E8 - Every
100 ms - Testing for 2008 to 2016, 2021
Bits 392 to 407 of the reply, 16 bits.
- Formula
(val × 10 ÷ 65535)- Range
- 0 to 10 V
- Unit
- V
Confirmed for 2017 to 2020, 2022 to 2024. In testing for 2008 to 2009, 2011 to 2012, 2015. Not supported for 2010, 2013 to 2014, 2016, 2021.
Wastegate control PWM, wastegate actuator FORTE_WASTEGATE_CTRL_PWM
- Request
21 19 - Service 21
PID 19 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 416 to 431 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
(val × 100 ÷ 32767)- Range
- -100 to 100 %
- Unit
- %
In testing for 2008 to 2022. Not supported for 2023 to 2024.
Wastegate position target, wastegate actuator FORTE_WASTEGATE_POS_TGT
- Request
21 19 - Service 21
PID 19 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 448 to 463 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
(val × 200 ÷ 32767)- Range
- -200 to 200 %
- Unit
- %
In testing for 2008 to 2022. Not supported for 2023 to 2024.
Wastegate position, wastegate actuator FORTE_WASTEGATE_POS
- Request
21 19 - Service 21
PID 19 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 432 to 447 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
(val × 200 ÷ 32767)- Range
- -200 to 200 %
- Unit
- %
In testing for 2008 to 2022. Not supported for 2023 to 2024.
Engine › Misfires
Emission-relevant misfires, cylinder #1 FORTE_MIS_CNT_EMIS_1
- Request
21 0D - Service 21
PID 0D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 48 to 63 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2008 to 2022. Not supported for 2023 to 2024.
Emission-relevant misfires, cylinder #2 FORTE_MIS_CNT_EMIS_2
- Request
21 0D - Service 21
PID 0D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 64 to 79 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2008 to 2022. Not supported for 2023 to 2024.
Emission-relevant misfires, cylinder #3 FORTE_MIS_CNT_EMIS_3
- Request
21 0D - Service 21
PID 0D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 80 to 95 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2008 to 2022. Not supported for 2023 to 2024.
Emission-relevant misfires, cylinder #4 FORTE_MIS_CNT_EMIS_4
- Request
21 0D - Service 21
PID 0D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 96 to 111 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2008 to 2022. Not supported for 2023 to 2024.
Misfires harmful for catalyst cylinder 1 FORTE_MIS_CAT_1
- Request
21 1D - Service 21
PID 1D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 160 to 175 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2008 to 2022. Not supported for 2023 to 2024.
Misfires harmful for catalyst cylinder 2 FORTE_MIS_CAT_2
- Request
21 1D - Service 21
PID 1D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 176 to 191 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2008 to 2022. Not supported for 2023 to 2024.
Misfires harmful for catalyst cylinder 3 FORTE_MIS_CAT_3
- Request
21 1D - Service 21
PID 1D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 192 to 207 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2008 to 2022. Not supported for 2023 to 2024.
Misfires harmful for catalyst cylinder 4 FORTE_MIS_CAT_4
- Request
21 1D - Service 21
PID 1D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 208 to 223 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2008 to 2022. Not supported for 2023 to 2024.
Misfires total counter, all cylinders FORTE_MIS_CNT_ALL
- Request
21 0D - Service 21
PID 0D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 432 to 447 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2008 to 2022. Not supported for 2023 to 2024.
Misfires total counter, cylinder #1 FORTE_MIS_CNT_1
- Request
21 0D - Service 21
PID 0D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 176 to 191 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2008 to 2022. Not supported for 2023 to 2024.
Misfires total counter, cylinder #2 FORTE_MIS_CNT_2
- Request
21 0D - Service 21
PID 0D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 192 to 207 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2008 to 2022. Not supported for 2023 to 2024.
Misfires total counter, cylinder #3 FORTE_MIS_CNT_3
- Request
21 0D - Service 21
PID 0D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 208 to 223 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2008 to 2022. Not supported for 2023 to 2024.
Misfires total counter, cylinder #4 FORTE_MIS_CNT_4
- Request
21 0D - Service 21
PID 0D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 224 to 239 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2008 to 2022. Not supported for 2023 to 2024.
Misfires, cylinder 1 FORTE_MIS_1_7E0
- Request
21 1D - Service 21
PID 1D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 32 to 47 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2008 to 2022. Not supported for 2023 to 2024.
Misfires, cylinder 2 FORTE_MIS_2_7E0
- Request
21 1D - Service 21
PID 1D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 48 to 63 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2008 to 2022. Not supported for 2023 to 2024.
Misfires, cylinder 3 FORTE_MIS_3_7E0
- Request
21 1D - Service 21
PID 1D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 64 to 79 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2008 to 2022. Not supported for 2023 to 2024.
Misfires, cylinder 4 FORTE_MIS_4_7E0
- Request
21 1D - Service 21
PID 1D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 80 to 95 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2008 to 2022. Not supported for 2023 to 2024.
Engine › OxygenSensors
02S Bank 1, Sensor 1 present O2S11_EXISTSSAE J1979Confirmed
- Request
01 13 - Service 01
PID 13 - Module
7E0 → 7E8 - Every
3600 s
Bit 7 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2022 to 2024. Supported for 2010 to 2014, 2016 to 2021.
02S Bank 1, Sensor 2 present O2S12_EXISTSSAE J1979Confirmed
- Request
01 13 - Service 01
PID 13 - Module
7E0 → 7E8 - Every
3600 s
Bit 6 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2022 to 2024. Supported for 2010 to 2014, 2016 to 2021.
02S Bank 1, Sensor 3 present O2S13_EXISTSSAE J1979Confirmed
- Request
01 13 - Service 01
PID 13 - Module
7E0 → 7E8 - Every
3600 s
Bit 5 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2022 to 2024. Supported for 2010 to 2014, 2016 to 2021.
02S Bank 1, Sensor 4 present O2S14_EXISTSSAE J1979Confirmed
- Request
01 13 - Service 01
PID 13 - Module
7E0 → 7E8 - Every
3600 s
Bit 4 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2022 to 2024. Supported for 2010 to 2014, 2016 to 2021.
02S Bank 2, Sensor 1 present O2S21_EXISTSSAE J1979Confirmed
- Request
01 13 - Service 01
PID 13 - Module
7E0 → 7E8 - Every
3600 s
Bit 3 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2022 to 2024. Supported for 2010 to 2014, 2016 to 2021.
02S Bank 2, Sensor 2 present O2S22_EXISTSSAE J1979Confirmed
- Request
01 13 - Service 01
PID 13 - Module
7E0 → 7E8 - Every
3600 s
Bit 2 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2022 to 2024. Supported for 2010 to 2014, 2016 to 2021.
02S Bank 2, Sensor 3 present O2S23_EXISTSSAE J1979Confirmed
- Request
01 13 - Service 01
PID 13 - Module
7E0 → 7E8 - Every
3600 s
Bit 1 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2022 to 2024. Supported for 2010 to 2014, 2016 to 2021.
02S Bank 2, Sensor 4 present O2S24_EXISTSSAE J1979Confirmed
- Request
01 13 - Service 01
PID 13 - Module
7E0 → 7E8 - Every
3600 s
Bit 0 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2022 to 2024. Supported for 2010 to 2014, 2016 to 2021.
Lambda value, Equivalence Ratio Bank 1, Sensor 1 LAMBDA11_CURRENTSAE J1979Confirmed
Pelican can show this parameter as the O2 lambda.
- Request
01 34 - Service 01
PID 34 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 32768)- Range
- 0 to 1.99
- Unit
- Number
Confirmed for 2013 to 2014, 2017 to 2020, 2022 to 2024. Supported for 2016, 2021.
O2S Output Voltage Bank 1, Sensor 2 O2S12SAE J1979Confirmed
- Request
01 15 - Service 01
PID 15 - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 200)- Range
- 0 to 1.275 V
- Unit
- V
Confirmed for 2022 to 2023. Supported for 2010 to 2014, 2016 to 2021, 2024.
SHRTFT associated with O2S11 SHRTFT11SAE J1979Confirmed
- Request
01 14 - Service 01
PID 14 - Module
7E0 → 7E8 - Every
1 s
Bits 8 to 15 of the reply, 8 bits.
- Formula
(val × 100 ÷ 128 − 128)- Range
- -100 to 99.22 %
- Unit
- %
Confirmed for 2022 to 2023. Supported for 2010 to 2014, 2016 to 2021, 2024.
Wide Range O2S Current, O2 Sensor Bank 1, Sensor 1 O2S11_CURRENTSAE J1979Confirmed
- Request
01 34 - Service 01
PID 34 - Module
7E0 → 7E8 - Every
250 ms
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val ÷ 256 − 128)- Range
- -128 to 127.996 mA
- Unit
- mA
Confirmed for 2013 to 2014, 2017 to 2020, 2022 to 2024. Supported for 2016, 2021.