INFINITI G Sedan

Engine parameters

The INFINITI G Sedan has 109 engine parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

Absolute load value LOAD_ABSConfirmed

  • Request01 43
  • Service 01PID 43
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 25700 %
Unit
%

Confirmed for 2013. Supported for 2011.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Absolute load value LOAD_ABSSAE J1979Confirmed

  • Request01 43
  • Service 01PID 43
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 25700 %
Unit
%

Confirmed for 2013. Supported for 2011.

Air conditioning compressor INFINITI_AC_COMP

  • Request22 13 07
  • Service 22DID 1307
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 1991 to 1996, 1999 to 2013.

All-wheel drive coupling temperature INFINITI_AWD_COUPLING_T

  • Request22 11 14
  • Service 22DID 1114
  • Module748 → 768
  • Every5 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 1991 to 1996, 1999 to 2013.

All-wheel drive electronic traction support solenoid INFINITI_AWD_ELECTRONIC

  • Request22 11 03
  • Service 22DID 1103
  • Module748 → 768
  • Every1 s
  • Testing

Bit 7 of the reply.

Formula
(val ÷ 50)
Range
0 to 0.02
Unit
Off or on

In testing for 1991 to 1996, 1999 to 2013.

All-wheel drive estimated engine torque INFINITI_AWD_ESTIMATED_ENG_TQ

  • Request22 11 05
  • Service 22DID 1105
  • Module748 → 768
  • Every250 ms
  • Testing

Bit 7 of the reply. The value is signed.

Formula
(val × 5 ÷ 2)
Range
-2.5 to 0
Unit
Off or on

In testing for 1991 to 1996, 1999 to 2013.

All-wheel drive request engine torque INFINITI_AWD_REQ_ENG_TQ

  • Request22 11 04
  • Service 22DID 1104
  • Module748 → 768
  • Every250 ms
  • Testing

Bit 7 of the reply. The value is signed.

Formula
(val × 5 ÷ 2)
Range
-2.5 to 0
Unit
Off or on

In testing for 1991 to 1996, 1999 to 2013.

Auto emergency braking system request INFINITI_AUTO_EMERGENCY

  • Request22 21 70
  • Service 22DID 2170
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 1991 to 1996, 1999 to 2013.

AWD, target traction control torque INFINITI_AWD_TGT_TRACTION

  • Request22 11 07
  • Service 22DID 1107
  • Module748 → 768
  • Every250 ms
  • Testing

Bit 7 of the reply.

Formula
(val × 2)
Range
0 to 2
Unit
Off or on

In testing for 1991 to 1996, 1999 to 2013.

Barometric pressure BAROSAE J1979Confirmed

Normally obtained from one of a dedicated barometric sensor, a MAP sensor at key-on and during certain modes of driving, or inferred from a MAF sensor and other inputs during certain modes of driving. The control module reports BARO from whatever source it is derived from.

  • Request01 33
  • Service 01PID 33
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 kPa
Unit
kPa

Confirmed for 2013. Supported for 2010 to 2012.

Base injection timing INFINITI_BASE_INJ_TIM

  • Request22 12 07
  • Service 22DID 1207
  • ModuleDA18 → 18
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 2048)
Range
0 to 31.99 ms
Unit
ms

In testing for 1991 to 1996, 1999 to 2013.

Braking detected multiplex signal INFINITI_BRAKING_DETECTED

  • Request22 20 0F
  • Service 22DID 200F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1991 to 1996, 1999 to 2013.

Butane percentage INFINITI_BUTANE_PERCENTAGE

  • Request21 AD
  • Service 21PID AD
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 200 to 207 of the reply, 8 bits.

Formula
(val × 7813 ÷ 20000)
Range
0 to 99.61 %
Unit
%

In testing for 1991 to 1996, 1999 to 2013.

Calculated engine load LOAD_PCTSAE J1979Confirmed

Represents the amount of work the engine is doing. Expected to reach 100% at wide open throttle/wide open pedal at any altitude, temperature or rpm for both naturally aspirated and boosted engines. If engine load is limited for powertrain protection e.g. engine/turbocharger protection, this value may not reach 100%. For hybrid vehicles, indicates the torque produced only by the internal combustion engine, not the torque being delivered by the entire powertrain. For electric vehicles, the meaning of this parameter is undefined.

Pelican can show this parameter as the engine load.

  • Request01 04
  • Service 01PID 04
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

Confirmed for 2013. Supported for 2010 to 2012.

Catalyst temperature bank 1, sensor 1 CATEMP11SAE J1979Confirmed

  • Request01 3C
  • Service 01PID 3C
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10 − 40)
Range
-40 to 6513.5 °C
Unit
°C

Confirmed for 2013. Supported for 2010 to 2012.

Catalyst temperature bank 2, sensor 1 CATEMP21SAE J1979Confirmed

  • Request01 3D
  • Service 01PID 3D
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10 − 40)
Range
-40 to 6513.5 °C
Unit
°C

Confirmed for 2013. Supported for 2010 to 2012.

Cold starting programming INFINITI_COLD_STARTING

  • Request21 AD
  • Service 21PID AD
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1991 to 1996, 1999 to 2013.

Commanded equivalence ratio EQ_RATSAE J1979Confirmed

Fuel systems that utilize conventional oxygen sensor display the inverse of the commanded open loop equivalence ratio (also known as lambda) while the fuel control system is in open loop. Will indicate 1.000 while in closed-loop fuel.

Pelican can show this parameter as the commanded lambda.

  • Request01 44
  • Service 01PID 44
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 2 ÷ 65535)
Range
0 to 1.99
Unit
Number

Confirmed for 2013.

Commanded evaporative purge EVAP_PCTSAE J1979Confirmed

  • Request01 2E
  • Service 01PID 2E
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

Confirmed for 2013. Supported for 2010 to 2012.

Commanded throttle actuator control TAC_PCTSAE J1979Confirmed

  • Request01 4C
  • Service 01PID 4C
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

Confirmed for 2013.

Coolant temperature INFINITI_ECT_7E0

  • Request22 14 06
  • Service 22DID 1406
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 1991 to 1996, 1999 to 2013.

Cooling fan high INFINITI_COOLING_FAN_HIGH

  • Request22 13 13
  • Service 22DID 1313
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 1991 to 1996, 1999 to 2013.

Cooling fan low INFINITI_COOLING_FAN_LOW

  • Request22 13 13
  • Service 22DID 1313
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 1991 to 1996, 1999 to 2013.

Cruise control INFINITI_CRUISE_CTRL

  • Request22 20 79
  • Service 22DID 2079
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 1991 to 1996, 1999 to 2013.

Duration of - button press INFINITI_DUR_BUTTON_PRESS_7E0

  • Request22 20 7C
  • Service 22DID 207C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 20)
Range
0 to 3276 s
Unit
s

In testing for 1991 to 1996, 1999 to 2013.

Duration of + button press INFINITI_DUR_BUTTON_PRESS

  • Request22 20 7B
  • Service 22DID 207B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 20)
Range
0 to 3276 s
Unit
s

In testing for 1991 to 1996, 1999 to 2013.

Duration of resume button press INFINITI_DUR_RESUME_BUTTON

  • Request22 20 7A
  • Service 22DID 207A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 20)
Range
0 to 3276 s
Unit
s

In testing for 1991 to 1996, 1999 to 2013.

Duration of suspend button press INFINITI_DUR_SUSPEND_BUTTON

  • Request22 20 7D
  • Service 22DID 207D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 20)
Range
0 to 3276 s
Unit
s

In testing for 1991 to 1996, 1999 to 2013.

Electric fuel pump learning value INFINITI_EFP_LEARNING

  • Request21 AD
  • Service 21PID AD
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 184 to 199 of the reply, 16 bits.

Formula
(val ÷ 65535 − 0.5)
Range
-0.5 to 0.5 %
Unit
%

In testing for 1991 to 1996, 1999 to 2013.

Engine coolant temperature ECTSAE J1979Confirmed

Your engine temperature must operate within a certain temperature range to operate efficiently and safely. If it runs too hot, then your engine could be permanently damaged. If it runs too cold, then your engine will use more fuel than necessary.

Pelican can show this parameter as the engine coolant temperature.

  • Request01 05
  • Service 01PID 05
  • Module7E0 → 7E8
  • Every500 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2013. Supported for 2010 to 2012.

Engine oil temperature INFINITI_EOT

  • Request22 11 1F
  • Service 22DID 111F
  • ModuleDA18 → 18
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 50)
Range
-50 to 205 °C
Unit
°C

In testing for 1991 to 1996, 1999 to 2013.

Engine RPM INFINITI_RPM

  • Request22 12 55
  • Service 22DID 1255
  • Module797 → 79A
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32767 to 32767
Unit
Number

In testing for 1991 to 1996, 1999 to 2011. Not supported for 2012 to 2013.

Engine RPM RPMSAE J1979Confirmed

  • Request01 0C
  • Service 01PID 0C
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 4)
Range
0 to 16383.75 rpm
Unit
rpm

Confirmed for 2013. Supported for 2010 to 2012.

Engine torque INFINITI_ENG_TQ

  • Request22 20 04
  • Service 22DID 2004
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 2 − 400)
Range
-400 to 32367 N·m
Unit
N·m

In testing for 1991 to 1996, 1999 to 2013.

Evap system vapor pressure EVAP_VPSAE J1979Confirmed

The pressure signal is normally obtained from a sensor located in the fuel tank or a sensor in an evaporative system vapor line.

  • Request01 32
  • Service 01PID 32
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 4000)
Range
-8192 to 8191.75 kPa
Unit
kPa

Confirmed for 2013. Supported for 2010 to 2012.

Front pinion angle INFINITI_FRONT_PINION_ANG

  • Request21 01
  • Service 21PID 01
  • Module75C → 77C
  • Every250 ms
  • Testing

Bits 208 to 223 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-3276 to 3276 °
Unit
°

In testing for 1991 to 1996, 1999 to 2013.

Gear INFINITI_GEAR

  • Request22 11 56
  • Service 22DID 1156
  • Module797 → 79A
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
1PARKPark
2REVERSEReverse
3NEUTRALNeutral
4DRIVEDrive
7ECOEco

In testing for 1991 to 1996, 1999 to 2011. Not supported for 2012 to 2013.

Head lamp INFINITI_HEAD_LAMP

  • Request21 01
  • Service 21PID 01
  • Module75C → 77C
  • Every250 ms
  • Testing

Bit 56 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 1991 to 1996, 1999 to 2013.

Headlamp level INFINITI_HEADLAMP_LEVEL

  • Request21 01
  • Service 21PID 01
  • Module75C → 77C
  • Every250 ms
  • Testing

Bits 96 to 111 of the reply, 16 bits.

Formula
(val × 49 ÷ 125)
Range
0 to 25689 %
Unit
%

In testing for 1991 to 1996, 1999 to 2013.

Height sensor initial value front INFINITI_HEIGHT_SENS_INIT_FRONT

  • Request21 01
  • Service 21PID 01
  • Module75C → 77C
  • Every250 ms
  • Testing

Bits 192 to 207 of the reply, 16 bits.

Formula
(val × 5 ÷ 1024)
Range
0 to 319.99 V
Unit
V

In testing for 1991 to 1996, 1999 to 2013.

Height sensor initial value rear INFINITI_HEIGHT_SENS_INIT

  • Request21 01
  • Service 21PID 01
  • Module75C → 77C
  • Every250 ms
  • Testing

Bits 176 to 191 of the reply, 16 bits.

Formula
(val × 5 ÷ 1024)
Range
0 to 319.99 V
Unit
V

In testing for 1991 to 1996, 1999 to 2013.

Height sensor signal front INFINITI_HEIGHT_SENS_SIG

  • Request21 01
  • Service 21PID 01
  • Module75C → 77C
  • Every250 ms
  • Testing

Bits 80 to 95 of the reply, 16 bits.

Formula
(val × 5 + 1024)
Range
0 to 328699 V
Unit
V

In testing for 1991 to 1996, 1999 to 2013.

Height sensor signal rear INFINITI_HEIGHT_SENS_SIG_REAR

  • Request21 01
  • Service 21PID 01
  • Module75C → 77C
  • Every250 ms
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
(val × 5 + 1024)
Range
0 to 328699 V
Unit
V

In testing for 1991 to 1996, 1999 to 2013.

Idle control mode INFINITI_IDLE_CTRL_MODE

  • Request22 13 07
  • Service 22DID 1307
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 1991 to 1996, 1999 to 2013.

Ignition advance INFINITI_IGN_ADVANCE

  • Request22 11 3C
  • Service 22DID 113C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × -1 + 112)
Range
-143 to 112
Unit
Number

In testing for 1991 to 1996, 1999 to 2013.

Ih_defactrposition INFINITI_IH_DEFACTRPOSITION

  • Request21 53
  • Service 21PID 53
  • Module744 → 764
  • Every1 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 1991 to 1996, 1999 to 2013.

Ih_feetventactrposition INFINITI_IH

  • Request21 53
  • Service 21PID 53
  • Module744 → 764
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 1991 to 1996, 1999 to 2013.

Ih_leftmixactrposition INFINITI_IH_LEFTMIXACTRPOSITION

  • Request21 53
  • Service 21PID 53
  • Module744 → 764
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 1991 to 1996, 1999 to 2013.

Ih_rearmixactrposition INFINITI_IH_REARMIXACTRPOSITION

  • Request21 53
  • Service 21PID 53
  • Module744 → 764
  • Every1 s
  • Testing

Bits 96 to 103 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 1991 to 1996, 1999 to 2013.

Ih_recyactrposition INFINITI_IH_RECYACTRPOSITION

  • Request21 53
  • Service 21PID 53
  • Module744 → 764
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 1991 to 1996, 1999 to 2013.

Ih_reserveactrposition INFINITI_IH_RESERVEACTRPOSITION

  • Request21 53
  • Service 21PID 53
  • Module744 → 764
  • Every1 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 1991 to 1996, 1999 to 2013.

Ih_rightmixactrposition INFINITI_IH_RIGHTMIXACTRPOSITION

  • Request21 53
  • Service 21PID 53
  • Module744 → 764
  • Every1 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 1991 to 1996, 1999 to 2013.

Intake air temperature IATSAE J1979Confirmed

  • Request01 0F
  • Service 01PID 0F
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2013. Supported for 2010 to 2012.

Intake camshaft advance, bank 2 INFINITI_CAM_ADV_B2

  • Request22 11 37
  • Service 22DID 1137
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 2 − 64)
Range
-64 to 63.5 °
Unit
°

In testing for 1991 to 1996, 1999 to 2013.

Intake manifold absolute pressure MAPSAE J1979Confirmed

  • Request01 0B
  • Service 01PID 0B
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 kPa
Unit
kPa

Confirmed for 2013. Supported for 2010 to 2012.

Intake valve timing solenoid duty, bank 2 INFINITI_CAM_DUTY_B2

  • Request22 11 39
  • Service 22DID 1139
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 25 ÷ 64)
Range
0 to 99.6 %
Unit
%

In testing for 1991 to 1996, 1999 to 2013.

Long term fuel trim (bank 1) LONGFT1SAE J1979Confirmed

  • Request01 07
  • Service 01PID 07
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 100 ÷ 128 − 100)
Range
-100 to 99.2 %
Unit
%

Confirmed for 2013. Supported for 2010 to 2012.

Long term fuel trim (bank 2) LONGFT2SAE J1979Confirmed

  • Request01 09
  • Service 01PID 09
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 100 ÷ 128 − 100)
Range
-100 to 99.2 %
Unit
%

Confirmed for 2013. Supported for 2010 to 2012.

Low-pressure fuel pump drive duty INFINITI_LPLI_PMP_PWM_SIG

  • Request21 AD
  • Service 21PID AD
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 160 to 175 of the reply, 16 bits.

Formula
(val × 0.0015259)
Range
0 to 99.99 %
Unit
%

In testing for 1991 to 1996, 1999 to 2013.

Manifold pressure INFINITI_MANIFOLD_P

  • Request22 14 0E
  • Service 22DID 140E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 1000)
Range
0 to 255000
Unit
Raw value

In testing for 1991 to 1996, 1999 to 2013.

Manual or assisted parking brake INFINITI_MANUAL_OR_ASSISTED

  • Request22 22 2B
  • Service 22DID 222B
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1991 to 1996, 1999 to 2013.

Mass Air Flow Sensor A MAFASAE J1979Confirmed

Pelican can show this parameter as the mass air flow.

  • Request01 66
  • Service 01PID 66
  • Module7E0 → 7E8
  • Every250 ms

Bits 8 to 23 of the reply, 16 bits.

Formula
(val ÷ 32)
Range
0 to 2047.96875 g/s
Unit
g/s

Confirmed for 2013.

Mass Air Flow Sensor B MAFBSAE J1979Confirmed

Pelican can show this parameter as the mass air flow.

  • Request01 66
  • Service 01PID 66
  • Module7E0 → 7E8
  • Every250 ms

Bits 24 to 39 of the reply, 16 bits.

Formula
(val ÷ 32)
Range
0 to 2047.96875 g/s
Unit
g/s

Confirmed for 2013.

Mass air flow sensor voltage, bank 2 INFINITI_MAF_V_B2

  • Request22 12 05
  • Service 22DID 1205
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 200)
Range
0 to 327 V
Unit
V

In testing for 1991 to 1996, 1999 to 2013.

Motor power INFINITI_MOTOR_PWR

  • Request22 11 46
  • Service 22DID 1146
  • Module797 → 79A
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 40)
Range
0 to 2621400 W
Unit
W

In testing for 1991 to 1996, 1999 to 2011. Not supported for 2012 to 2013.

Motor torque, actual INFINITI_MOTOR_TQ

  • Request22 12 54
  • Service 22DID 1254
  • Module797 → 79A
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 64)
Range
-512 to 511.984 N·m
Unit
N·m

In testing for 1991 to 1996, 1999 to 2013.

Motor torque, nominal INFINITI_MOTOR_TQ_NOMINAL

  • Request22 11 28
  • Service 22DID 1128
  • Module797 → 79A
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 64)
Range
-512 to 511.984 N·m
Unit
N·m

In testing for 1991 to 1996, 1999 to 2013.

Number of abnormal cc/sl transitions INFINITI_NUM_ABNORMAL_CC_SL

  • Request22 20 7E
  • Service 22DID 207E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1991 to 1996, 1999 to 2013.

Oh_defactrreq INFINITI_OH_DEFACTRREQ

  • Request21 53
  • Service 21PID 53
  • Module744 → 764
  • Every1 s
  • Testing

Bits 80 to 87 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 1991 to 1996, 1999 to 2013.

Oh_feetventactrreq INFINITI_OH_FEETVENTACTRREQ

  • Request21 53
  • Service 21PID 53
  • Module744 → 764
  • Every1 s
  • Testing

Bits 48 to 55 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 1991 to 1996, 1999 to 2013.

Oh_leftmixactrreq INFINITI_OH_LEFTMIXACTRREQ

  • Request21 53
  • Service 21PID 53
  • Module744 → 764
  • Every1 s
  • Testing

Bits 56 to 63 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 1991 to 1996, 1999 to 2013.

Oh_rearmixactrreq INFINITI_OH_REARMIXACTRREQ

  • Request21 53
  • Service 21PID 53
  • Module744 → 764
  • Every1 s
  • Testing

Bits 104 to 111 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 1991 to 1996, 1999 to 2013.

Oh_recyactrreq INFINITI_OH_RECYACTRREQ

  • Request21 53
  • Service 21PID 53
  • Module744 → 764
  • Every1 s
  • Testing

Bits 64 to 71 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 1991 to 1996, 1999 to 2013.

Oh_reserveactrreq INFINITI_OH_RESERVEACTRREQ

  • Request21 53
  • Service 21PID 53
  • Module744 → 764
  • Every1 s
  • Testing

Bits 88 to 95 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 1991 to 1996, 1999 to 2013.

Oh_rightmixactrreq INFINITI_OH_RIGHTMIXACTRREQ

  • Request21 53
  • Service 21PID 53
  • Module744 → 764
  • Every1 s
  • Testing

Bits 72 to 79 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 1991 to 1996, 1999 to 2013.

Power switch INFINITI_IGN

  • Request22 13 04
  • Service 22DID 1304
  • Module797 → 79A
  • Every1 s
  • Testing

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 1991 to 1996, 1999 to 2011. Not supported for 2012 to 2013.

Reverse INFINITI_REVERSE

  • Request21 01
  • Service 21PID 01
  • Module75C → 77C
  • Every250 ms
  • Testing

Bit 57 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 1991 to 1996, 1999 to 2013.

Selector position INFINITI_SELECTOR_POS

  • Request21 01
  • Service 21PID 01
  • Module75C → 77C
  • Every250 ms
  • Testing

Bits 48 to 55 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1991 to 1996, 1999 to 2013.

Short term fuel trim (bank 1) SHRTFT1SAE J1979Confirmed

Correction being used by the closed-loop fuel algorithm.

Pelican can show this parameter as the short term fuel trim.

  • Request01 06
  • Service 01PID 06
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 100 ÷ 128 − 100)
Range
-100 to 99.2 %
Unit
%

Confirmed for 2013. Supported for 2010 to 2012.

Short term fuel trim (bank 2) SHRTFT2SAE J1979Confirmed

Correction being used by the closed-loop fuel algorithm.

Pelican can show this parameter as the short term fuel trim.

  • Request01 08
  • Service 01PID 08
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 100 ÷ 128 − 100)
Range
-100 to 99.2 %
Unit
%

Confirmed for 2013. Supported for 2010 to 2012.

Starter button INFINITI_STARTER_BUTTON

  • Request22 20 79
  • Service 22DID 2079
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 1991 to 1996, 1999 to 2013.

Starter wear counter INFINITI_STARTER_WEAR_CNT

  • Request22 22 AA
  • Service 22DID 22AA
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 40 to 63 of the reply, 24 bits.

Formula
val
Range
0 to 16777215
Unit
Number

In testing for 1991 to 1996, 1999 to 2013.

Steer angle INFINITI_STEER_ANG

  • Request21 01
  • Service 21PID 01
  • Module75C → 77C
  • Every250 ms
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 6553 °
Unit
°

In testing for 1991 to 1996, 1999 to 2013.

Swivel angle left INFINITI_SWIVEL_ANG_LEFT

  • Request21 01
  • Service 21PID 01
  • Module75C → 77C
  • Every250 ms
  • Testing

Bits 144 to 159 of the reply, 16 bits.

Formula
(val ÷ 10 − 32000)
Range
-32000 to -25447 °
Unit
°

In testing for 1991 to 1996, 1999 to 2013.

Swivel angle right INFINITI_SWIVEL_ANG_RIGHT

  • Request21 01
  • Service 21PID 01
  • Module75C → 77C
  • Every250 ms
  • Testing

Bits 160 to 175 of the reply, 16 bits.

Formula
(val ÷ 10 − 32000)
Range
-32000 to -25447 °
Unit
°

In testing for 1991 to 1996, 1999 to 2013.

Swivel sensor left INFINITI_SWIVEL_SENS_LEFT

  • Request21 01
  • Service 21PID 01
  • Module75C → 77C
  • Every250 ms
  • Testing

Bits 112 to 127 of the reply, 16 bits.

Formula
(val ÷ 10 − 32000)
Range
-32000 to -25447 °
Unit
°

In testing for 1991 to 1996, 1999 to 2013.

Swivel sensor right INFINITI_SWIVEL_SENS_RIGHT

  • Request21 01
  • Service 21PID 01
  • Module75C → 77C
  • Every250 ms
  • Testing

Bits 128 to 143 of the reply, 16 bits.

Formula
(val ÷ 10 − 32000)
Range
-32000 to -25447 °
Unit
°

In testing for 1991 to 1996, 1999 to 2013.

Tank pressure INFINITI_TANK_P

  • Request21 AD
  • Service 21PID AD
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 120 to 135 of the reply, 16 bits.

Formula
(val ÷ 2)
Range
0 to 32767
Unit
Raw value

In testing for 1991 to 1996, 1999 to 2013.

Throttle opening INFINITI_THROTTLE_OPENING

  • Request22 14 0F
  • Service 22DID 140F
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 7 ÷ 20)
Range
0 to 89.25 °
Unit
°

In testing for 1991 to 1996, 1999 to 2013.

Timing advance SPARKADVSAE J1979Confirmed

Ignition timing spark advance for the first cylinder. Measured in degrees before dead center. Minus is degrees before dead center, positive is degrees after.

  • Request01 0E
  • Service 01PID 0E
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 2 − 64)
Range
-64 to 63.5 °
Unit
°

Confirmed for 2013. Supported for 2010 to 2012.

Traction control/anti-yaw control INFINITI_TRACTION_CTRL_ANTI

  • Request22 20 79
  • Service 22DID 2079
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 1991 to 1996, 1999 to 2013.

Type of fuel currently being used by the vehicle FUEL_TYPSAE J1979Confirmed

  • Request01 51
  • Service 01PID 51
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
1GASGasoline/petrol
2METHMethanol
3ETHEthanol
4DSLDiesel
5LPGLiquefied petroleum gas
6CNGCompressed natural gas
7PROPPropane
8ELECBattery/electric
9BI_GASBi-fuel vehicle using gasoline/petrol
10BI_METHBi-fuel vehicle using methanol
11BI_ETHBi-fuel vehicle using ethanol
12BI_LPGBi-fuel vehicle using LPG
13BI_CNGBi-fuel vehicle using CNG
14BI_PROPBi-fuel vehicle using propane
15BI_ELECBi-fuel vehicle using battery
16BI_MIXBi-fuel vehicle using battery and combustion engine for propulsion
17HYB_GASHybrid vehicle using gasoline engine for propulsion
18HYB_ETHHybrid vehicle using gasoline engine on ethanol for propulsion
19HYB_DSLHybrid vehicle using diesel engine for propulsion
20HYB_ELECHybrid vehicle using battery for propulsion
21HYB_MIXHybrid vehicle using battery and combustion engine for propulsion
22HYB_REGHybrid vehicle in regeneration mode
23BI_DSLBi-fuel vehicle using diesel
24BI_NGBi-fuel vehicle using natural gas
25BI_DSLBi-fuel vehicle using diesel
26NGNatural gas
27DSL_CNGDual fuel vehicle using diesel and CNG
28DSL_LNGDual fuel vehicle using diesel and LNG
29FC_H2Fuel cell utilizing hydrogen
30HICE_HHOHydrogen Internal Combustion Engine
31KEROKerosene
32HFOHeavy Fuel Oil

Confirmed for 2013.

Vapor lock temperature INFINITI_VAPOR_LOCK_T

  • Request21 AD
  • Service 21PID AD
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
(val × 3 ÷ 4 − 48)
Range
-48 to 143 °C
Unit
°C

In testing for 1991 to 1996, 1999 to 2013.

Variable valve timing oil temperature INFINITI_VVT_EOT

  • Request22 12 66
  • Service 22DID 1266
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 3 ÷ 128 − 273)
Range
-273 to 1262 °C
Unit
°C

In testing for 1991 to 1996, 1999 to 2013.

Engine › Internal

MAF Sensor A supported MAFA_SUPSAE J1979Confirmed

  • Request01 66
  • Service 01PID 66
  • Module7E0 → 7E8
  • Every250 ms

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2013.

MAF Sensor B supported MAFB_SUPSAE J1979Confirmed

  • Request01 66
  • Service 01PID 66
  • Module7E0 → 7E8
  • Every250 ms

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2013.

Engine › OxygenSensors

02S Bank 1, Sensor 1 present O2S11_EXISTSSAE J1979Confirmed

  • Request01 13
  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2013. Supported for 2010 to 2012.

02S Bank 1, Sensor 2 present O2S12_EXISTSSAE J1979Confirmed

  • Request01 13
  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2013. Supported for 2010 to 2012.

02S Bank 1, Sensor 3 present O2S13_EXISTSSAE J1979Confirmed

  • Request01 13
  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2013. Supported for 2010 to 2012.

02S Bank 1, Sensor 4 present O2S14_EXISTSSAE J1979Confirmed

  • Request01 13
  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2013. Supported for 2010 to 2012.

02S Bank 2, Sensor 1 present O2S21_EXISTSSAE J1979Confirmed

  • Request01 13
  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2013. Supported for 2010 to 2012.

02S Bank 2, Sensor 2 present O2S22_EXISTSSAE J1979Confirmed

  • Request01 13
  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2013. Supported for 2010 to 2012.

02S Bank 2, Sensor 3 present O2S23_EXISTSSAE J1979Confirmed

  • Request01 13
  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2013. Supported for 2010 to 2012.

02S Bank 2, Sensor 4 present O2S24_EXISTSSAE J1979Confirmed

  • Request01 13
  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2013. Supported for 2010 to 2012.

Lambda value, Equivalence Ratio Bank 1, Sensor 1 LAMBDA11_VOLTSAE J1979Confirmed

Pelican can show this parameter as the O2 lambda.

  • Request01 24
  • Service 01PID 24
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 32768)
Range
0 to 1.99
Unit
Number

Confirmed for 2013. Supported for 2010, 2012.

O2S Output Voltage Bank 1, Sensor 2 O2S12SAE J1979Confirmed

  • Request01 15
  • Service 01PID 15
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 200)
Range
0 to 1.275 V
Unit
V

Confirmed for 2013. Supported for 2010 to 2012.

O2S Output Voltage Bank 2, Sensor 2 O2S22SAE J1979Confirmed

  • Request01 19
  • Service 01PID 19
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 200)
Range
0 to 1.275 V
Unit
V

Confirmed for 2013. Supported for 2010, 2012.

SHRTFT associated with O2S11 SHRTFT11SAE J1979Confirmed

  • Request01 14
  • Service 01PID 14
  • Module7E0 → 7E8
  • Every1 s

Bits 8 to 15 of the reply, 8 bits.

Formula
(val × 100 ÷ 128 − 128)
Range
-100 to 99.22 %
Unit
%

Confirmed for 2013. Supported for 2010 to 2012.

SHRTFT associated with O2S22 SHRTFT22SAE J1979Confirmed

  • Request01 19
  • Service 01PID 19
  • Module7E0 → 7E8
  • Every1 s

Bits 8 to 15 of the reply, 8 bits.

Formula
(val × 100 ÷ 128 − 128)
Range
-100 to 99.22 %
Unit
%

Confirmed for 2013. Supported for 2010, 2012.

Wide Range O2S Voltage, O2 Sensor Bank 1, Sensor 1 O2S11_VOLTSAE J1979Confirmed

  • Request01 24
  • Service 01PID 24
  • Module7E0 → 7E8
  • Every250 ms

Bits 16 to 31 of the reply, 16 bits.

Formula
(val ÷ 8196)
Range
0 to 7.999 V
Unit
V

Confirmed for 2013. Supported for 2010, 2012.

Keyboard shortcuts

jk/↓↑
Move down or up through a list or a grid.
hl/←→
Move across a row or between cards.
Enter
Open the focused link.
f
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.