Hyundai Santa Fe Hybrid

Engine parameters

The Hyundai Santa Fe Hybrid has 321 engine parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

Engine oil temperature SFHEV_EOTConfirmed

  • Request22 E0 01
  • Service 22DID E001
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2020 to 2024, 2026

Example reply from a 2025 Hyundai Santa Fe Hybrid.

Bits 272 to 279 of the reply, 8 bits.

0x7C = 124 → (124 × 3 ÷ 4 − 48) = 45 °C

Formula
(val × 3 ÷ 4 − 48)
Range
-48 to 143 °C
Unit
°C

Confirmed for 2025. In testing for 2020 to 2024, 2026.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

4WD calculated clutch power SFHEV_AWD_CALC_CLU_POWER

  • Request22 01 A3
  • Service 22DID 01A3
  • Module740 → 748
  • Every250 ms
  • Testing

Bits 56 to 71 of the reply, 16 bits.

Formula
(val × 39.062 ÷ 10000)
Range
0 to 255 kWh
Unit
kWh

In testing for 2020 to 2026.

4WD calculated engine power SFHEV_AWD_CALC_ENG_POWER

  • Request22 01 A3
  • Service 22DID 01A3
  • Module740 → 748
  • Every250 ms
  • Testing

Bits 72 to 87 of the reply, 16 bits.

Formula
(val × 9.766 ÷ 10000)
Range
0 to 64 kWh
Unit
kWh

In testing for 2020 to 2026.

4WD calculated, commanded torque SFHEV_AWD_CALC_CMD_TQ

  • Request22 01 A1
  • Service 22DID 01A1
  • Module740 → 748
  • Every250 ms
  • Testing

Bits 40 to 55 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 8)
Range
-4096 to 4095.875 N·m
Unit
N·m

In testing for 2020 to 2026.

4WD clutch, actual pressure SFHEV_AWD_CLU_ACT_P

  • Request22 01 A1
  • Service 22DID 01A1
  • Module740 → 748
  • Every250 ms
  • Testing

Bits 144 to 159 of the reply, 16 bits. The value is signed.

Formula
(val × 19.53 ÷ 10000)
Range
-63.99 to 63.99 bar
Unit
bar

In testing for 2020 to 2026.

4WD clutch, actual torque SFHEV_AWD_CLU_ACT_TQ

  • Request22 01 A1
  • Service 22DID 01A1
  • Module740 → 748
  • Every250 ms
  • Testing

Bits 128 to 143 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 8)
Range
-4096 to 4095.875 N·m
Unit
N·m

In testing for 2020 to 2026.

4WD max clutch stress SFHEV_AWD_MAX_CLU_STRESS

  • Request22 01 A1
  • Service 22DID 01A1
  • Module740 → 748
  • Every250 ms
  • Testing

Bits 88 to 103 of the reply, 16 bits.

Formula
(val × 19.531 ÷ 10000)
Range
0 to 100 %
Unit
%

In testing for 2020 to 2026.

4WD pump current SFHEV_AWD_PMP_CURRENT

  • Request22 01 A1
  • Service 22DID 01A1
  • Module740 → 748
  • Every250 ms
  • Testing

Bits 112 to 127 of the reply, 16 bits. The value is signed.

Formula
(val × 78.125 ÷ 10000)
Range
-256 to 255 A
Unit
A

In testing for 2020 to 2026.

4WD pump PWM duty SFHEV_AWD_PMP_PWM_DUTY

  • Request22 01 A1
  • Service 22DID 01A1
  • Module740 → 748
  • Every250 ms
  • Testing

Bits 56 to 71 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-3276.8 to 100 %
Unit
%

In testing for 2020 to 2026.

Absolute load value LOAD_ABSSAE J1979Confirmed

  • Request01 43
  • Service 01PID 43
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 25700 %
Unit
%

Confirmed for 2021, 2023, 2025. Supported for 2022, 2024.

Accumulated normal charging energy SFHEV_ACCUMULATED_NORMAL

  • Request22 01 11
  • Service 22DID 0111
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 96 to 127 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 kWh
Unit
kWh

In testing for 2020 to 2026.

Actual engine torque TQ_ACTSAE J1979Confirmed

  • Request01 62
  • Service 01PID 62
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 125)
Range
-125 to 130 %
Unit
%

Confirmed for 2021, 2023, 2025.

Adaptation value for lower stop of wastegate actuator SFHEV_ADPT_LO_STOP

  • Request21 19
  • Service 21PID 19
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 384 to 399 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
(val × 1.53 ÷ 10000)
Range
-5.01 to 5.01 V
Unit
V

In testing for 2020 to 2026.

Air conditioning pressure SFHEV_AC_P

  • Request22 E0 14
  • Service 22DID E014
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 112 to 119 of the reply, 8 bits.

Formula
(val × 13.79)
Range
0 to 3516.45 kPa
Unit
kPa

In testing for 2020 to 2026.

Air conditioning relay SFHEV_AC_RELAY

  • Request22 ED 01
  • Service 22DID ED01
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bit 101 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2020 to 2026.

Air flow rate from mass air flow sensor MAFSAE J1979Confirmed

Pelican can show this parameter as the mass air flow.

  • Request01 10
  • Service 01PID 10
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 655.35 g/s
Unit
g/s

Confirmed for 2021, 2023, 2025. Supported for 2022, 2024.

Automatic transmission fluid temperature SFHEV_ATF_T

Pelican can show this parameter as the transmission fluid temperature.

  • Request21 A0
  • Service 21PID A0
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 104 to 111 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2020 to 2024, 2026. Not supported for 2025.

Automatic transmission fluid temperature SFHEV_ATF_T_7E1

Pelican can show this parameter as the transmission fluid temperature.

  • Request22 01 A0
  • Service 22DID 01A0
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 104 to 111 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2020 to 2026.

AUX amps LDC SFHEV_AUX_AMPS_LDC

  • Request21 02
  • Service 21PID 02
  • Module7E2 → 7EA
  • Every1 s
  • Testing

Bits 128 to 143 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 655 A
Unit
A

In testing for 2020 to 2026.

Barometric pressure BAROSAE J1979Confirmed

Normally obtained from one of a dedicated barometric sensor, a MAP sensor at key-on and during certain modes of driving, or inferred from a MAF sensor and other inputs during certain modes of driving. The control module reports BARO from whatever source it is derived from.

  • Request01 33
  • Service 01PID 33
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 kPa
Unit
kPa

Confirmed for 2021, 2023. Supported for 2022, 2024 to 2025.

Barometric pressure SFHEV_BAROMETRIC_PRESSURE

  • Request21 13
  • Service 21PID 13
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 312 to 319 of the reply, 8 bits.

Formula
(val ÷ 2)
Range
0 to 127.5 kPa
Unit
kPa

In testing for 2020 to 2026.

Boost pressure SFHEV_BOOST_P

  • Request22 E0 F2
  • Service 22DID E0F2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 496 to 511 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Raw value

In testing for 2020 to 2026.

Boost pressure upstream SFHEV_BOOST_P_UP

  • Request22 E0 03
  • Service 22DID E003
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 280 to 295 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val × 39 ÷ 500)
Range
0 to 5111
Unit
Raw value

In testing for 2020 to 2026.

Boost pressure upstream, desired SFHEV_BOOST_P_UP_DES

  • Request22 E0 03
  • Service 22DID E003
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 312 to 327 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val × 39 ÷ 500)
Range
0 to 5111
Unit
Raw value

In testing for 2020 to 2026.

Calculated engine load LOAD_PCTSAE J1979Confirmed

Represents the amount of work the engine is doing. Expected to reach 100% at wide open throttle/wide open pedal at any altitude, temperature or rpm for both naturally aspirated and boosted engines. If engine load is limited for powertrain protection e.g. engine/turbocharger protection, this value may not reach 100%. For hybrid vehicles, indicates the torque produced only by the internal combustion engine, not the torque being delivered by the entire powertrain. For electric vehicles, the meaning of this parameter is undefined.

Pelican can show this parameter as the engine load.

  • Request01 04
  • Service 01PID 04
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

Confirmed for 2021, 2023, 2025. Supported for 2022, 2024.

Calculated oil temperature SFHEV_CALC_OIL_T

  • Request22 E0 11
  • Service 22DID E011
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 304 to 311 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2020 to 2026.

Camshaft exhaust position, actual SFHEV_CAM_EXH_POS_ACT

  • Request21 20
  • Service 21PID 20
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 80 to 87 of the reply, 8 bits.

Formula
(val × -3 ÷ 8 − 40)
Range
-135 to -40 °
Unit
°

In testing for 2020 to 2026.

Camshaft exhaust position, commanded SFHEV_CAM_EXH_POS_CMD

  • Request21 20
  • Service 21PID 20
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 112 to 119 of the reply, 8 bits.

Formula
(val × -3 ÷ 8 − 40)
Range
-135 to -40 °
Unit
°

In testing for 2020 to 2026.

Camshaft intake position, actual SFHEV_CAM_INT_POS_ACT

  • Request21 20
  • Service 21PID 20
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 72 to 79 of the reply, 8 bits.

Formula
(val × 3 ÷ 8 + 60)
Range
0 to 155 °
Unit
°

In testing for 2020 to 2026.

Camshaft intake position, commanded SFHEV_CAM_INT_POS_CMD

  • Request21 20
  • Service 21PID 20
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 104 to 111 of the reply, 8 bits.

Formula
(val × 3 ÷ 8 + 60)
Range
0 to 155 °
Unit
°

In testing for 2020 to 2026.

Catalyst damaging misfires total all cylinders SFHEV_CATALYST_DAMAGING_MISFIRES_TOTAL_ALL_CYLINDERS

  • Request22 E0 0D
  • Service 22DID E00D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 448 to 463 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2026.

Catalyst damaging misfires total all cylinders SFHEV_CATDMG_MIS_TOT_ALL

  • Request21 08
  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 400 to 415 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2026.

Catalyst damaging misfires total, cylinder 1 SFHEV_CATALYST_DAMAGING_MISFIRES_TOTAL_C1

  • Request22 E0 0D
  • Service 22DID E00D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 304 to 319 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2026.

Catalyst damaging misfires total, cylinder 1 SFHEV_CATDMG_MIS_TOT_1

  • Request21 08
  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 256 to 271 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2026.

Catalyst damaging misfires total, cylinder 2 SFHEV_CATALYST_DAMAGING_MISFIRES_TOTAL_C2

  • Request22 E0 0D
  • Service 22DID E00D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 320 to 335 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2026.

Catalyst damaging misfires total, cylinder 2 SFHEV_CATDMG_MIS_TOT_2

  • Request21 08
  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 272 to 287 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2026.

Catalyst damaging misfires total, cylinder 3 SFHEV_CATALYST_DAMAGING_MISFIRES_TOTAL_C3

  • Request22 E0 0D
  • Service 22DID E00D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 336 to 351 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2026.

Catalyst damaging misfires total, cylinder 3 SFHEV_CATDMG_MIS_TOT_3

  • Request21 08
  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 288 to 303 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2026.

Catalyst damaging misfires total, cylinder 4 SFHEV_CATALYST_DAMAGING_MISFIRES_TOTAL_C4

  • Request22 E0 0D
  • Service 22DID E00D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 352 to 367 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2026.

Catalyst damaging misfires total, cylinder 4 SFHEV_CATDMG_MIS_TOT_4

  • Request21 08
  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 304 to 319 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2026.

Catalyst damaging misfires total, cylinder 5 SFHEV_CATDMG_MIS_TOT_5

  • Request21 08
  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 320 to 335 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2026.

Catalyst damaging misfires total, cylinder 6 SFHEV_CATDMG_MIS_TOT_6

  • Request21 08
  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 336 to 351 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2026.

Catalyst temperature bank 1, sensor 1 CATEMP11SAE J1979Confirmed

  • Request01 3C
  • Service 01PID 3C
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10 − 40)
Range
-40 to 6513.5 °C
Unit
°C

Confirmed for 2021, 2023. Supported for 2022, 2024 to 2025.

Clutch solenoid duty SFHEV_CLUTCH_SOLENOID_DUTY

  • Request21 C0
  • Service 21PID C0
  • Module7E5
  • Every250 ms
  • Testing

Bits 88 to 95 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2020 to 2026.

Commanded EGR EGR_PCTSAE J1979Confirmed

  • Request01 2C
  • Service 01PID 2C
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

Confirmed for 2021, 2023, 2025. Supported for 2022, 2024.

Commanded equivalence ratio EQ_RATSAE J1979Confirmed

Fuel systems that utilize conventional oxygen sensor display the inverse of the commanded open loop equivalence ratio (also known as lambda) while the fuel control system is in open loop. Will indicate 1.000 while in closed-loop fuel.

Pelican can show this parameter as the commanded lambda.

  • Request01 44
  • Service 01PID 44
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 2 ÷ 65535)
Range
0 to 1.99
Unit
Number

Confirmed for 2021, 2023, 2025. Supported for 2022, 2024.

Commanded evaporative purge EVAP_PCTSAE J1979Confirmed

  • Request01 2E
  • Service 01PID 2E
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

Confirmed for 2021, 2023, 2025. Supported for 2022, 2024.

Commanded evaporative purge SFHEV_COMMANDED_EVAPORATIVE_PURGE

  • Request21 02
  • Service 21PID 02
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 160 to 167 of the reply, 8 bits.

Formula
(val × 0.390625)
Range
0 to 99.6 %
Unit
%

In testing for 2020 to 2026.

Commanded throttle actuator SFHEV_COMMANDED_THROTTLE_ACTUATOR

  • Request21 14
  • Service 21PID 14
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
(val × 0.390625)
Range
0 to 99.6 %
Unit
%

In testing for 2020 to 2026.

Commanded throttle actuator control TAC_PCTSAE J1979Confirmed

  • Request01 4C
  • Service 01PID 4C
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

Confirmed for 2021, 2023, 2025.

Commanded torque SFHEV_COMMANDED_TORQUE

  • Request21 C0
  • Service 21PID C0
  • Module7E5
  • Every250 ms
  • Testing

Bits 80 to 87 of the reply, 8 bits.

Formula
(val × 10)
Range
0 to 2550 N·m
Unit
N·m

In testing for 2020 to 2026.

Coolant SFHEV_COOLANT_FAN

  • Request21 14
  • Service 21PID 14
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 96 to 103 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2020 to 2026.

Coolant fan PWM SFHEV_CLT_FAN_PWM

  • Request22 E0 14
  • Service 22DID E014
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 88 to 103 of the reply, 16 bits.

Formula
(val × 15.21 ÷ 10000)
Range
0 to 99.67 %
Unit
%

In testing for 2020 to 2026.

Coolant temperature SFHEV_HVAC_COOLANT_T

  • Request22 01 02
  • Service 22DID 0102
  • Module7B3 → 7BB
  • Every1 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
(val ÷ 2 − 40)
Range
-40 to 87.5 °C
Unit
°C

In testing for 2020 to 2026.

Coverage driven length SFHEV_COVERAGE_DRIVEN

  • Request22 E0 09
  • Service 22DID E009
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 392 to 423 of the reply, 32 bits. The bytes are in little-endian order.

Formula
(val ÷ 1000)
Range
0 to 4294967 km
Unit
km

In testing for 2020 to 2026.

Crankshaft torque SFHEV_CRANK_TQ

  • Request22 ED 05
  • Service 22DID ED05
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 240 to 247 of the reply, 8 bits.

Formula
(val × 600 ÷ 255)
Range
0 to 600 N·m
Unit
N·m

In testing for 2020 to 2026.

Cylinder 1 injection time, 1st pulse SFHEV_CYL_1_INJ_TIME_1ST

  • Request21 23
  • Service 21PID 23
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 264 to 279 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val × 4 ÷ 1000)
Range
0 to 262.14 ms
Unit
ms

In testing for 2020 to 2026.

Cylinder 1 injection time, 2nd pulse SFHEV_CYL_1_INJ_TIME_2ND

  • Request21 23
  • Service 21PID 23
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 200 to 215 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val × 4 ÷ 1000)
Range
0 to 262.14 ms
Unit
ms

In testing for 2020 to 2026.

Cylinder 2 injection time, 1st pulse SFHEV_CYL_2_INJ_TIME_1ST

  • Request21 23
  • Service 21PID 23
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 280 to 295 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val × 4 ÷ 1000)
Range
0 to 262.14 ms
Unit
ms

In testing for 2020 to 2026.

Cylinder 2 injection time, 2nd pulse SFHEV_CYL_2_INJ_TIME_2ND

  • Request21 23
  • Service 21PID 23
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 216 to 231 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val × 4 ÷ 1000)
Range
0 to 262.14 ms
Unit
ms

In testing for 2020 to 2026.

Cylinder 3 injection time, 1st pulse SFHEV_CYL_3_INJ_TIME_1ST

  • Request21 23
  • Service 21PID 23
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 296 to 311 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val × 4 ÷ 1000)
Range
0 to 262.14 ms
Unit
ms

In testing for 2020 to 2026.

Cylinder 3 injection time, 2nd pulse SFHEV_CYL_3_INJ_TIME_2ND

  • Request21 23
  • Service 21PID 23
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 232 to 247 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val × 4 ÷ 1000)
Range
0 to 262.14 ms
Unit
ms

In testing for 2020 to 2026.

Cylinder 4 injection time, 1st pulse SFHEV_CYL_4_INJ_TIME_1ST

  • Request21 23
  • Service 21PID 23
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 312 to 327 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val × 4 ÷ 1000)
Range
0 to 262.14 ms
Unit
ms

In testing for 2020 to 2026.

Cylinder 4 injection time, 2nd pulse SFHEV_CYL_4_INJ_TIME_2ND

  • Request21 23
  • Service 21PID 23
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 248 to 263 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val × 4 ÷ 1000)
Range
0 to 262.14 ms
Unit
ms

In testing for 2020 to 2026.

Diesel particulate filter differential pressure SFHEV_DPF_DIFF_P_7E0

  • Request22 ED 03
  • Service 22DID ED03
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 288 to 295 of the reply, 8 bits.

Formula
(val × 431.373 ÷ 100)
Range
0 to 1100
Unit
Raw value

In testing for 2020 to 2026.

Diesel particulate filter regeneration count SFHEV_DPF_REGEN_CNT

  • Request22 ED 03
  • Service 22DID ED03
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 440 to 447 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2020 to 2026.

Diesel particulate filter regeneration state SFHEV_DPF_REGENERATION_STATE

  • Request21 06
  • Service 21PID 06
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bit 207 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2020 to 2026.

Diesel particulate filter successful regeneration count SFHEV_DPF_SUCCESSFUL_REGEN

  • Request22 E0 F2
  • Service 22DID E0F2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 432 to 447 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2026.

Direct injection time 1 SFHEV_DI_TIME_1

  • Request21 0B
  • Service 21PID 0B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 32 to 47 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val × 100 ÷ 13107)
Range
0 to 500 ms
Unit
ms

In testing for 2020 to 2026.

Direct injection time 2 SFHEV_DI_TIME_2

  • Request21 0B
  • Service 21PID 0B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 48 to 63 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val × 100 ÷ 13107)
Range
0 to 500 ms
Unit
ms

In testing for 2020 to 2026.

Direct injection time 3 SFHEV_DI_TIME_3

  • Request21 0B
  • Service 21PID 0B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 64 to 79 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val × 100 ÷ 13107)
Range
0 to 500 ms
Unit
ms

In testing for 2020 to 2026.

Direct injection time 4 SFHEV_DI_TIME_4

  • Request21 0B
  • Service 21PID 0B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 80 to 95 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val × 100 ÷ 13107)
Range
0 to 500 ms
Unit
ms

In testing for 2020 to 2026.

Direct injection time 5 SFHEV_DI_TIME_5

  • Request21 0B
  • Service 21PID 0B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 96 to 111 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val × 100 ÷ 13107)
Range
0 to 500 ms
Unit
ms

In testing for 2020 to 2026.

Direct injection time 6 SFHEV_DI_TIME_6

  • Request21 0B
  • Service 21PID 0B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 112 to 127 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val × 100 ÷ 13107)
Range
0 to 500 ms
Unit
ms

In testing for 2020 to 2026.

Disconnector actuator motor current SFHEV_DISCONNECTOR_ACTUATOR_MOTOR_CURRENT

  • Request22 E0 05
  • Service 22DID E005
  • Module7E2 → 7EA
  • Every1 s
  • Testing

Bits 96 to 103 of the reply, 8 bits. The value is signed.

Formula
(val × 2)
Range
-256 to 254 A
Unit
A

In testing for 2020 to 2026.

Disconnector disengage last time SFHEV_DISCONNECTOR_DISENGAGE_LAST_TIME

  • Request22 E0 05
  • Service 22DID E005
  • Module7E2 → 7EA
  • Every1 s
  • Testing

Bits 80 to 87 of the reply, 8 bits.

Formula
val
Range
0 to 255 ms
Unit
ms

In testing for 2020 to 2026.

Disconnector end point SFHEV_DISCONNECTOR_END_POINT

  • Request22 E0 05
  • Service 22DID E005
  • Module7E2 → 7EA
  • Every1 s
  • Testing

Bits 64 to 79 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val ÷ 128)
Range
0 to 511 mm
Unit
mm

In testing for 2020 to 2026.

Disconnector inverter PWM duty SFHEV_DISCONNECTOR_INVERTER_PWM_DUTY

  • Request22 E0 05
  • Service 22DID E005
  • Module7E2 → 7EA
  • Every1 s
  • Testing

Bits 104 to 119 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
(val × 78.125 ÷ 10000)
Range
0 to 100 %
Unit
%

In testing for 2020 to 2026.

Disconnector meet point SFHEV_DISCONNECTOR_MEET_POINT

  • Request22 E0 05
  • Service 22DID E005
  • Module7E2 → 7EA
  • Every1 s
  • Testing

Bits 48 to 63 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val ÷ 128)
Range
0 to 511 mm
Unit
mm

In testing for 2020 to 2026.

Disconnector stroke position SFHEV_DISCONNECTOR_STROKE_POSITION

  • Request22 E0 05
  • Service 22DID E005
  • Module7E2 → 7EA
  • Every1 s
  • Testing

Bits 32 to 47 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val ÷ 128)
Range
0 to 511 mm
Unit
mm

In testing for 2020 to 2026.

Disconnector zero count offset SFHEV_DISCONNECTOR_ZERO_COUNT_OFFSET

  • Request22 E0 05
  • Service 22DID E005
  • Module7E2 → 7EA
  • Every1 s
  • Testing

Bits 120 to 135 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val
Range
-32768 to 32767
Unit
Number

In testing for 2020 to 2026.

Dual-clutch transmission clutch 1, pressure sensor a SFHEV_DUAL_CLU_TRANS_CLU_1_P

  • Request22 01 A5
  • Service 22DID 01A5
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 192 to 207 of the reply, 16 bits.

Formula
(val × 19.53 ÷ 10000)
Range
0 to 127 bar
Unit
bar

In testing for 2020 to 2026.

Dual-clutch transmission clutch 2, pressure sensor b SFHEV_DUAL_CLU_TRANS_CLU_2_P_B

  • Request22 01 A5
  • Service 22DID 01A5
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 208 to 223 of the reply, 16 bits.

Formula
(val × 19.53 ÷ 10000)
Range
0 to 127 bar
Unit
bar

In testing for 2020 to 2026.

Dual-clutch transmission fluid temperature 1 SFHEV_DUAL_CLU_ATF_T_1

  • Request22 01 A5
  • Service 22DID 01A5
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 48 to 55 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2020 to 2026.

Dual-clutch transmission fluid temperature 2 SFHEV_DUAL_CLU_ATF_T_2

  • Request22 01 A5
  • Service 22DID 01A5
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 56 to 63 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2020 to 2026.

Dual-clutch transmission line pressure, sensor c SFHEV_DUAL_CLU_TRANS_LINE_P_C

  • Request22 01 A5
  • Service 22DID 01A5
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 224 to 239 of the reply, 16 bits.

Formula
(val × 19.53 ÷ 10000)
Range
0 to 127 bar
Unit
bar

In testing for 2020 to 2026.

EGR error EGR_ERRSAE J1979Confirmed

  • Request01 2D
  • Service 01PID 2D
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 100 ÷ 128 − 100)
Range
-100 to 99.22 %
Unit
%

Confirmed for 2021, 2023. Supported for 2022, 2024 to 2025.

Emission relevant misfires total all cylinders SFHEV_EMIS_MIS_TOT_ALL

  • Request21 08
  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 384 to 399 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2026.

Emission relevant misfires total all cylinders SFHEV_EMISSION_RELEVANT_MISFIRES_TOTAL_ALL_CYLINDERS

  • Request22 E0 0D
  • Service 22DID E00D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 432 to 447 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2026.

Emission relevant misfires total, cylinder 1 SFHEV_EMIS_MIS_TOT_1

  • Request21 08
  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 128 to 143 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2026.

Emission relevant misfires total, cylinder 1 SFHEV_EMISSION_RELEVANT_MISFIRES_TOTAL_C1

  • Request22 E0 0D
  • Service 22DID E00D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 176 to 191 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2026.

Emission relevant misfires total, cylinder 2 SFHEV_EMIS_MIS_TOT_2

  • Request21 08
  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 144 to 159 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2026.

Emission relevant misfires total, cylinder 2 SFHEV_EMISSION_RELEVANT_MISFIRES_TOTAL_C2

  • Request22 E0 0D
  • Service 22DID E00D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 192 to 207 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2026.

Emission relevant misfires total, cylinder 3 SFHEV_EMIS_MIS_TOT_3

  • Request21 08
  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 160 to 175 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2026.

Emission relevant misfires total, cylinder 3 SFHEV_EMISSION_RELEVANT_MISFIRES_TOTAL_C3

  • Request22 E0 0D
  • Service 22DID E00D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 208 to 223 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2026.

Emission relevant misfires total, cylinder 4 SFHEV_EMIS_MIS_TOT_4

  • Request21 08
  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 176 to 191 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2026.

Emission relevant misfires total, cylinder 4 SFHEV_EMISSION_RELEVANT_MISFIRES_TOTAL_C4

  • Request22 E0 0D
  • Service 22DID E00D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 224 to 239 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2026.

Emission relevant misfires total, cylinder 5 SFHEV_EMIS_MIS_TOT_5

  • Request21 08
  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 192 to 207 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2026.

Emission relevant misfires total, cylinder 6 SFHEV_EMIS_MIS_TOT_6

  • Request21 08
  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 208 to 223 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2026.

Engine coolant temperature SFHEV_ENGINE_COOLANT_T

  • Request21 01
  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 200 to 207 of the reply, 8 bits.

Formula
(val × 0.75 − 48)
Range
-48 to 143.25 °C
Unit
°C

In testing for 2020 to 2024, 2026. Not supported for 2025.

Engine coolant temperature 1 ECT_1SAE J1979Confirmed

  • Request01 67
  • Service 01PID 67
  • Module7E0 → 7E8
  • Every1 s

Bits 8 to 15 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2021, 2023, 2025.

Engine coolant temperature 2 ECT_2SAE J1979Confirmed

  • Request01 67
  • Service 01PID 67
  • Module7E0 → 7E8
  • Every1 s

Bits 16 to 23 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2021, 2023, 2025.

Engine Friction - Percent Torque TQ_FRSAE J1979Confirmed

  • Request01 8E
  • Service 01PID 8E
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 125)
Range
-125 to 130 %
Unit
%

Confirmed for 2021, 2023. Supported for 2025.

Engine oil temperature SFHEV_ENGINE_OIL_T

  • Request21 01
  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 272 to 279 of the reply, 8 bits.

Formula
(val × 0.75 − 48)
Range
-48 to 143.25 °C
Unit
°C

In testing for 2020 to 2024, 2026. Not supported for 2025.

Engine oil temperature SFHEV_EOTConfirmed

  • Request22 E0 01
  • Service 22DID E001
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2020 to 2024, 2026

Example reply from a 2025 Hyundai Santa Fe Hybrid.

Bits 272 to 279 of the reply, 8 bits.

0x7C = 124 → (124 × 3 ÷ 4 − 48) = 45 °C

Formula
(val × 3 ÷ 4 − 48)
Range
-48 to 143 °C
Unit
°C

Confirmed for 2025. In testing for 2020 to 2024, 2026.

Engine oil temperature SFHEV_EOT_7E0

  • Request22 ED 07
  • Service 22DID ED07
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 152 to 159 of the reply, 8 bits.

Formula
(val × 0.7843 − 50)
Range
-50 to 149.9965 °C
Unit
°C

In testing for 2020 to 2026.

Engine oil temperature SFHEV_EOT_V2

  • Request22 ED 02
  • Service 22DID ED02
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 184 to 191 of the reply, 8 bits.

Formula
(val − 4)
Range
-4 to 251 °C
Unit
°C

In testing for 2020 to 2024, 2026. Not supported for 2025.

Engine reference torque TQ_REFSAE J1979Confirmed

  • Request01 63
  • Service 01PID 63
  • Module7E0 → 7E8
  • Every86400 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 N·m
Unit
N·m

Confirmed for 2021, 2023. Supported for 2025.

Engine RPM RPMSAE J1979Confirmed

  • Request01 0C
  • Service 01PID 0C
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 4)
Range
0 to 16383.75 rpm
Unit
rpm

Confirmed for 2021, 2023, 2025. Supported for 2022, 2024.

Engine RPM SFHEV_ENGINE_RPM_TCM

  • Request21 A0
  • Service 21PID A0
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
(val ÷ 4)
Range
0 to 16383.75 rpm
Unit
rpm

In testing for 2020 to 2024, 2026. Not supported for 2025.

Engine RPM SFHEV_RPM

  • Request21 C0
  • Service 21PID C0
  • Module7E5
  • Every250 ms
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
(val ÷ 4)
Range
0 to 16383.75 rpm
Unit
rpm

In testing for 2020 to 2026.

Engine run time, total SFHEV_ENG_RUN_TIME_TOT

  • Request21 0E
  • Service 21PID 0E
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 80 to 95 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val × 6)
Range
0 to 393209.9999 min
Unit
min

In testing for 2020 to 2026.

Engine, actual torque SFHEV_ENG_ACT_TQ

  • Request22 ED 01
  • Service 22DID ED01
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 240 to 247 of the reply, 8 bits.

Formula
(val × 23529 ÷ 10000)
Range
0 to 599.9895 N·m
Unit
N·m

In testing for 2020 to 2026.

Evap system vapor pressure (wide) EVAP_VP_WIDESAE J1979Confirmed

The pressure signal is normally obtained from a sensor located in the fuel tank or a sensor in an evaporative system vapor line.

  • Request01 54
  • Service 01PID 54
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 1000)
Range
-32767 to 32768 kPa
Unit
kPa

Confirmed for 2021.

Exhaust cam oil control valve duty SFHEV_OIL_CTRL_VLV_IMPULSE_WIDTH

  • Request21 20
  • Service 21PID 20
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 160 to 167 of the reply, 8 bits.

Formula
(val × 20 ÷ 51)
Range
0 to 100 %
Unit
%

In testing for 2020 to 2026.

Exhaust camshaft position SFHEV_EXH_CAM_POS

  • Request22 E0 20
  • Service 22DID E020
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 88 to 103 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
(val ÷ 128)
Range
-256 to 255 °
Unit
°

In testing for 2020 to 2026.

Exhaust Gas Recirculation Temp Sensor A (Bank 1, Sensor 1) EGRTASAE J1979Confirmed

  • Request01 6B
  • Service 01PID 6B
  • Module7E0 → 7E8
  • Every250 ms

Bits 8 to 15 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2021, 2023. Supported for 2025.

Exhaust Gas Recirculation Temp Sensor B (Bank 2, Sensor 1) EGRTBSAE J1979Confirmed

  • Request01 6B
  • Service 01PID 6B
  • Module7E0 → 7E8
  • Every250 ms

Bits 24 to 31 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2021, 2023. Supported for 2025.

Exhaust Gas Recirculation Temp Sensor C (Bank 1, Sensor 2) EGRTCSAE J1979Confirmed

  • Request01 6B
  • Service 01PID 6B
  • Module7E0 → 7E8
  • Every250 ms

Bits 16 to 23 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2021, 2023. Supported for 2025.

Exhaust Gas Recirculation Temp Sensor D (Bank 2, Sensor 2) EGRTDSAE J1979Confirmed

  • Request01 6B
  • Service 01PID 6B
  • Module7E0 → 7E8
  • Every250 ms

Bits 32 to 39 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2021, 2023. Supported for 2025.

Exhaust gas temperature SFHEV_EXHAUST_GAS_T

  • Request21 03
  • Service 21PID 03
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 368 to 375 of the reply, 8 bits.

Formula
(val × 4.709803922 + 99)
Range
99 to 1300 °C
Unit
°C

In testing for 2020 to 2026.

Exhaust gas temperature before gasoline particulate filter sensor 1 SFHEV_EXH_GAS_T_BEFORE_GPF_1

  • Request22 E0 09
  • Service 22DID E009
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 288 to 303 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val × 12 ÷ 125)
Range
0 to 6291 °C
Unit
°C

In testing for 2020 to 2026.

Exhaust gas temperature before gasoline particulate filter sensor 2 SFHEV_EXH_GAS_T_BEFORE_GPF_2

  • Request22 E0 09
  • Service 22DID E009
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 304 to 319 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val × 12 ÷ 125)
Range
0 to 6291 °C
Unit
°C

In testing for 2020 to 2026.

Exhaust temperature 1, upstream of oxidation catalyst SFHEV_EXH_T_1_UP_OXICAT

  • Request22 ED 03
  • Service 22DID ED03
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 296 to 303 of the reply, 8 bits.

Formula
(val × 4.7098 + 99)
Range
0 to 1299.999 °C
Unit
°C

In testing for 2020 to 2026.

Exhaust temperature 2, upstream of DPF SFHEV_EXH_T_2_UP_DPF

  • Request22 ED 03
  • Service 22DID ED03
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 304 to 311 of the reply, 8 bits.

Formula
(val × 4.7098 + 99)
Range
0 to 1299.999 °C
Unit
°C

In testing for 2020 to 2026.

Fuel rail pressure FRPSAE J1979Confirmed

Fuel rail pressure at the engine when the reading is referenced to atmosphere (gage pressure).

  • Request01 23
  • Service 01PID 23
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 10)
Range
0 to 655350 kPa
Unit
kPa

Confirmed for 2021, 2023. Supported for 2022, 2024 to 2025.

Gasoline direct injection time bank a, 1 SFHEV_GDI_IT_A1

  • Request22 E0 05
  • Service 22DID E005
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 224 to 239 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val ÷ 10)
Range
0 to 6553.5 ms
Unit
ms

In testing for 2020 to 2026.

Gasoline direct injection time bank a, 2 SFHEV_GDI_IT_A2

  • Request22 E0 05
  • Service 22DID E005
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 240 to 255 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val ÷ 10)
Range
0 to 6553.5 ms
Unit
ms

In testing for 2020 to 2026.

Gasoline direct injection time bank a, 3 SFHEV_GDI_IT_A3

  • Request22 E0 05
  • Service 22DID E005
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 256 to 271 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val ÷ 10)
Range
0 to 6553.5 ms
Unit
ms

In testing for 2020 to 2026.

Gasoline direct injection time bank a, 4 SFHEV_GDI_IT_A4

  • Request22 E0 05
  • Service 22DID E005
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 272 to 287 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val ÷ 10)
Range
0 to 6553.5 ms
Unit
ms

In testing for 2020 to 2026.

Gasoline direct injection time bank b, 1 SFHEV_GDI_IT_B1

  • Request22 E0 05
  • Service 22DID E005
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 352 to 367 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val ÷ 10)
Range
0 to 6553.5 ms
Unit
ms

In testing for 2020 to 2026.

Gasoline direct injection time bank b, 2 SFHEV_GDI_IT_B2

  • Request22 E0 05
  • Service 22DID E005
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 368 to 383 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val ÷ 10)
Range
0 to 6553.5 ms
Unit
ms

In testing for 2020 to 2026.

Gasoline direct injection time bank b, 3 SFHEV_GDI_IT_B3

  • Request22 E0 05
  • Service 22DID E005
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 384 to 399 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val ÷ 10)
Range
0 to 6553.5 ms
Unit
ms

In testing for 2020 to 2026.

Gasoline direct injection time bank b, 4 SFHEV_GDI_IT_B4

  • Request22 E0 05
  • Service 22DID E005
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 400 to 415 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val ÷ 10)
Range
0 to 6553.5 ms
Unit
ms

In testing for 2020 to 2026.

Heat SFHEV_HEAT

  • Request21 C0
  • Service 21PID C0
  • Module7E5
  • Every250 ms
  • Testing

Bits 96 to 103 of the reply, 8 bits.

Formula
val
Range
0 to 255 °C
Unit
°C

In testing for 2020 to 2026.

Idle control mode SFHEV_IDLE_CONTROL_MODE

  • Request21 00
  • Service 21PID 00
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 120 to 127 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2020 to 2026.

Ignition retard due to knock control 1 SFHEV_IGN_RETARD_KNOCK_1

  • Request21 19
  • Service 21PID 19
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 104 to 111 of the reply, 8 bits.

Formula
(val × 0.75 − 191.25)
Range
-191.25 to 0 °
Unit
°

In testing for 2020 to 2026.

Ignition retard due to knock control 2 SFHEV_IGN_RETARD_KNOCK_2

  • Request21 19
  • Service 21PID 19
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 112 to 119 of the reply, 8 bits.

Formula
(val × 0.75 − 191.25)
Range
-191.25 to 0 °
Unit
°

In testing for 2020 to 2026.

Ignition retard due to knock control 3 SFHEV_IGN_RETARD_KNOCK_3

  • Request21 19
  • Service 21PID 19
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 120 to 127 of the reply, 8 bits.

Formula
(val × 0.75 − 191.25)
Range
-191.25 to 0 °
Unit
°

In testing for 2020 to 2026.

Ignition retard due to knock control 4 SFHEV_IGN_RETARD_KNOCK_4

  • Request21 19
  • Service 21PID 19
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 128 to 135 of the reply, 8 bits.

Formula
(val × 0.75 − 191.25)
Range
-191.25 to 0 °
Unit
°

In testing for 2020 to 2026.

Injection duration cylinder 1 SFHEV_INJ_DUR_1Confirmed

  • Request22 E0 02
  • Service 22DID E002
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2020 to 2024, 2026

Example reply from a 2025 Hyundai Santa Fe Hybrid.

Bits 176 to 191 of the reply, 16 bits. The bytes are in little-endian order.

0x0000 = 0 → (0 ÷ 1220.7) = 0 s

Formula
(val ÷ 1220.7)
Range
0 to 53 s
Unit
s

Confirmed for 2025. In testing for 2020 to 2024, 2026.

Injection duration cylinder 2 SFHEV_INJ_DUR_2Confirmed

  • Request22 E0 02
  • Service 22DID E002
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2020 to 2024, 2026

Example reply from a 2025 Hyundai Santa Fe Hybrid.

Bits 192 to 207 of the reply, 16 bits. The bytes are in little-endian order.

0x0000 = 0 → (0 ÷ 1220.7) = 0 s

Formula
(val ÷ 1220.7)
Range
0 to 53 s
Unit
s

Confirmed for 2025. In testing for 2020 to 2024, 2026.

Injection duration cylinder 3 SFHEV_INJ_DUR_3Confirmed

  • Request22 E0 02
  • Service 22DID E002
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2020 to 2024, 2026

Example reply from a 2025 Hyundai Santa Fe Hybrid.

Bits 208 to 223 of the reply, 16 bits. The bytes are in little-endian order.

0x0000 = 0 → (0 ÷ 1220.7) = 0 s

Formula
(val ÷ 1220.7)
Range
0 to 53 s
Unit
s

Confirmed for 2025. In testing for 2020 to 2024, 2026.

Injection duration cylinder 4 SFHEV_INJ_DUR_4Confirmed

  • Request22 E0 02
  • Service 22DID E002
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2020 to 2024, 2026

Example reply from a 2025 Hyundai Santa Fe Hybrid.

Bits 224 to 239 of the reply, 16 bits. The bytes are in little-endian order.

0x0000 = 0 → (0 ÷ 1220.7) = 0 s

Formula
(val ÷ 1220.7)
Range
0 to 53 s
Unit
s

Confirmed for 2025. In testing for 2020 to 2024, 2026.

Injection impulse 1, cylinder 1 SFHEV_INJ_IMPULSE_1_CYL_1

  • Request22 E0 23
  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 200 to 215 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val ÷ 250)
Range
0 to 262.14 ms
Unit
ms

In testing for 2020 to 2026.

Injection impulse 1, cylinder 2 SFHEV_INJ_IMPULSE_1_CYL_2

  • Request22 E0 23
  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 216 to 231 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val ÷ 250)
Range
0 to 262.14 ms
Unit
ms

In testing for 2020 to 2026.

Injection impulse 1, cylinder 3 SFHEV_INJ_IMPULSE_1_CYL_3

  • Request22 E0 23
  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 232 to 247 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val ÷ 250)
Range
0 to 262.14 ms
Unit
ms

In testing for 2020 to 2026.

Injection impulse 1, cylinder 4 SFHEV_INJ_IMPULSE_1_CYL_4

  • Request22 E0 23
  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 248 to 263 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val ÷ 250)
Range
0 to 262.14 ms
Unit
ms

In testing for 2020 to 2026.

Injection impulse 2, cylinder 1 SFHEV_INJ_IMPULSE_2_CYL_1

  • Request22 E0 23
  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 264 to 279 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val ÷ 250)
Range
0 to 262.14 ms
Unit
ms

In testing for 2020 to 2026.

Injection impulse 2, cylinder 2 SFHEV_INJ_IMPULSE_2_CYL_2

  • Request22 E0 23
  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 280 to 295 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val ÷ 250)
Range
0 to 262.14 ms
Unit
ms

In testing for 2020 to 2026.

Injection impulse 2, cylinder 3 SFHEV_INJ_IMPULSE_2_CYL_3

  • Request22 E0 23
  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 296 to 311 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val ÷ 250)
Range
0 to 262.14 ms
Unit
ms

In testing for 2020 to 2026.

Injection impulse 2, cylinder 4 SFHEV_INJ_IMPULSE_2_CYL_4

  • Request22 E0 23
  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 312 to 327 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val ÷ 250)
Range
0 to 262.14 ms
Unit
ms

In testing for 2020 to 2026.

Injection impulse 3, cylinder 1 SFHEV_INJ_IMPULSE_3_CYL_1

  • Request22 E0 23
  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 328 to 343 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val ÷ 25)
Range
0 to 2621.4 ms
Unit
ms

In testing for 2020 to 2026.

Injection impulse 3, cylinder 2 SFHEV_INJ_IMPULSE_3_CYL_2

  • Request22 E0 23
  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 344 to 359 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val ÷ 25)
Range
0 to 2621.4 ms
Unit
ms

In testing for 2020 to 2026.

Injection impulse 3, cylinder 3 SFHEV_INJ_IMPULSE_3_CYL_3

  • Request22 E0 23
  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 360 to 375 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val ÷ 25)
Range
0 to 2621.4 ms
Unit
ms

In testing for 2020 to 2026.

Injection impulse 3, cylinder 4 SFHEV_INJ_IMPULSE_3_CYL_4

  • Request22 E0 23
  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 376 to 391 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val ÷ 25)
Range
0 to 2621.4 ms
Unit
ms

In testing for 2020 to 2026.

Injector correction factor 1 SFHEV_INJ_CORR_FACTOR_1

  • Request22 E0 07
  • Service 22DID E007
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 208 to 223 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val × 2 ÷ 65535)
Range
0 to 2
Unit
Number

In testing for 2020 to 2026.

Injector correction factor 2 SFHEV_INJ_CORR_FACTOR_2

  • Request22 E0 07
  • Service 22DID E007
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 224 to 239 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val × 2 ÷ 65535)
Range
0 to 2
Unit
Number

In testing for 2020 to 2026.

Injector correction factor 3 SFHEV_INJ_CORR_FACTOR_3

  • Request22 E0 07
  • Service 22DID E007
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 240 to 255 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val × 2 ÷ 65535)
Range
0 to 2
Unit
Number

In testing for 2020 to 2026.

Injector correction factor 4 SFHEV_INJ_CORR_FACTOR_4

  • Request22 E0 07
  • Service 22DID E007
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 256 to 271 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val × 2 ÷ 65535)
Range
0 to 2
Unit
Number

In testing for 2020 to 2026.

Intake air temperature IATSAE J1979Confirmed

  • Request01 0F
  • Service 01PID 0F
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2021, 2023, 2025. Supported for 2022, 2024.

Intake air temperature SFHEV_EITConfirmed

  • Request22 E0 01
  • Service 22DID E001
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2020 to 2024, 2026

Example reply from a 2025 Hyundai Santa Fe Hybrid.

Bits 264 to 271 of the reply, 8 bits.

0x50 = 80 → (80 × 3 ÷ 4 − 48) = 12 °C

Formula
(val × 3 ÷ 4 − 48)
Range
-48 to 143 °C
Unit
°C

Confirmed for 2025. In testing for 2020 to 2024, 2026.

Intake air temperature SFHEV_INTAKE_AIR_T

  • Request21 01
  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 264 to 271 of the reply, 8 bits.

Formula
(val × 0.75 − 48)
Range
-48 to 143.25 °C
Unit
°C

In testing for 2020 to 2024, 2026. Not supported for 2025.

Intake cam oil control valve duty SFHEV_OIL_CTRL_VLV_IMPULSE

  • Request21 20
  • Service 21PID 20
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 144 to 151 of the reply, 8 bits.

Formula
(val × 20 ÷ 51)
Range
0 to 100 %
Unit
%

In testing for 2020 to 2026.

Intake camshaft position SFHEV_INT_CAM_POS

  • Request22 E0 20
  • Service 22DID E020
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 72 to 87 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
(val ÷ 128)
Range
-256 to 255 °
Unit
°

In testing for 2020 to 2026.

Intake camshaft position actual SFHEV_INTAKE_CAMSHAFT_POSITION_ACTUAL

  • Request21 17
  • Service 21PID 17
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 40 to 55 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
(val ÷ 128)
Range
-256 to 255 °
Unit
°

In testing for 2020 to 2026.

Intake camshaft position commanded SFHEV_INTAKE_CAMSHAFT_POSITION_COMMANDED

  • Request21 17
  • Service 21PID 17
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 32 to 39 of the reply, 8 bits. The value is signed.

Formula
(val ÷ 2)
Range
-64 to 63.5 °
Unit
°

In testing for 2020 to 2026.

Intake manifold absolute pressure MAPSAE J1979Confirmed

  • Request01 0B
  • Service 01PID 0B
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 kPa
Unit
kPa

Confirmed for 2021, 2023, 2025. Supported for 2022, 2024.

Intake manifold absolute pressure SFHEV_INTAKE_MANIFOLD_ABSOLUTE_PRESSURE

  • Request21 01
  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 128 to 143 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val ÷ 256)
Range
0 to 255 kPa
Unit
kPa

In testing for 2020 to 2024, 2026. Not supported for 2025.

Inverter temperature SFHEV_HVAC_INVERTER_T

  • Request22 01 02
  • Service 22DID 0102
  • Module7B3 → 7BB
  • Every1 s
  • Testing

Bits 96 to 103 of the reply, 8 bits.

Formula
(val ÷ 2 − 40)
Range
-40 to 87.5 °C
Unit
°C

In testing for 2020 to 2026.

Knock detected SFHEV_KNOCK_DETECTED

  • Request21 00
  • Service 21PID 00
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 200 to 207 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2020 to 2026.

Knock detected SFHEV_KNOCK_DETECTED_7E0Confirmed

  • Request22 E0 04
  • Service 22DID E004
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2020 to 2024, 2026

Example reply from a 2025 Hyundai Santa Fe Hybrid.

Bits 168 to 175 of the reply, 8 bits.

0x00 = 0 → 0

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2025. In testing for 2020 to 2024, 2026.

Knock learn, cylinder 1 SFHEV_KNOCK_LEARN_1Confirmed

  • Request22 E0 0A
  • Service 22DID E00A
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2020 to 2024, 2026

Example reply from a 2025 Hyundai Santa Fe Hybrid.

Bits 160 to 167 of the reply, 8 bits. The value is signed.

0x00 = 0 → (0 ÷ 5) = 0 °

Formula
(val ÷ 5)
Range
-25 to 25 °
Unit
°

Confirmed for 2025. In testing for 2020 to 2024, 2026.

Knock learn, cylinder 2 SFHEV_KNOCK_LEARN_2Confirmed

  • Request22 E0 0A
  • Service 22DID E00A
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2020 to 2024, 2026

Example reply from a 2025 Hyundai Santa Fe Hybrid.

Bits 168 to 175 of the reply, 8 bits. The value is signed.

0x00 = 0 → (0 ÷ 5) = 0 °

Formula
(val ÷ 5)
Range
-25 to 25 °
Unit
°

Confirmed for 2025. In testing for 2020 to 2024, 2026.

Knock learn, cylinder 3 SFHEV_KNOCK_LEARN_3Confirmed

  • Request22 E0 0A
  • Service 22DID E00A
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2020 to 2024, 2026

Example reply from a 2025 Hyundai Santa Fe Hybrid.

Bits 176 to 183 of the reply, 8 bits. The value is signed.

0x00 = 0 → (0 ÷ 5) = 0 °

Formula
(val ÷ 5)
Range
-25 to 25 °
Unit
°

Confirmed for 2025. In testing for 2020 to 2024, 2026.

Knock learn, cylinder 4 SFHEV_KNOCK_LEARN_4Confirmed

  • Request22 E0 0A
  • Service 22DID E00A
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2020 to 2024, 2026

Example reply from a 2025 Hyundai Santa Fe Hybrid.

Bits 184 to 191 of the reply, 8 bits. The value is signed.

0x00 = 0 → (0 ÷ 5) = 0 °

Formula
(val ÷ 5)
Range
-25 to 25 °
Unit
°

Confirmed for 2025. In testing for 2020 to 2024, 2026.

Knock retard cylinder #1 SFHEV_KNOCK_RETARD_CYLINDER_1

  • Request21 16
  • Service 21PID 16
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 96 to 103 of the reply, 8 bits.

Formula
(val × 0.75)
Range
0 to 191.25 °
Unit
°

In testing for 2020 to 2026.

Knock retard cylinder #2 SFHEV_KNOCK_RETARD_CYLINDER_2

  • Request21 16
  • Service 21PID 16
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 104 to 111 of the reply, 8 bits.

Formula
(val × 0.75)
Range
0 to 191.25 °
Unit
°

In testing for 2020 to 2026.

Knock retard cylinder #3 SFHEV_KNOCK_RETARD_CYLINDER_3

  • Request21 16
  • Service 21PID 16
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 112 to 119 of the reply, 8 bits.

Formula
(val × 0.75)
Range
0 to 191.25 °
Unit
°

In testing for 2020 to 2026.

Knock retard cylinder #4 SFHEV_KNOCK_RETARD_CYLINDER_4

  • Request21 16
  • Service 21PID 16
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 120 to 127 of the reply, 8 bits.

Formula
(val × 0.75)
Range
0 to 191.25 °
Unit
°

In testing for 2020 to 2026.

Knock retard cylinder 1 SFHEV_KNOCK_RETARD_CYL_1

  • Request21 19
  • Service 21PID 19
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 168 to 175 of the reply, 8 bits.

Formula
(val × 0.75 − 191.25)
Range
-191.25 to 0 °
Unit
°

In testing for 2020 to 2026.

Knock retard cylinder 1, alternate SFHEV_KNOCK_RETARD_1_E019

  • Request22 E0 19
  • Service 22DID E019
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 168 to 175 of the reply, 8 bits.

Formula
(val × 0.75 − 191.25)
Range
-191.25 to 0 °
Unit
°

In testing for 2020 to 2026.

Knock retard cylinder 1, alternate SFHEV_KNOCK_RETARD_CYL_1_ALT

  • Request21 0A
  • Service 21PID 0A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 160 to 167 of the reply, 8 bits.

Formula
(val ÷ 1.333333333)
Range
0 to 191.25 °
Unit
°

In testing for 2020 to 2026.

Knock retard cylinder 2 SFHEV_KNOCK_RETARD_CYL_2

  • Request21 19
  • Service 21PID 19
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 176 to 183 of the reply, 8 bits.

Formula
(val × 0.75 − 191.25)
Range
-191.25 to 0 °
Unit
°

In testing for 2020 to 2026.

Knock retard cylinder 2, alternate SFHEV_KNOCK_RETARD_2_E019

  • Request22 E0 19
  • Service 22DID E019
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 176 to 183 of the reply, 8 bits.

Formula
(val × 0.75 − 191.25)
Range
-191.25 to 0 °
Unit
°

In testing for 2020 to 2026.

Knock retard cylinder 2, alternate SFHEV_KNOCK_RETARD_CYL_2_ALT

  • Request21 0A
  • Service 21PID 0A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 168 to 175 of the reply, 8 bits.

Formula
(val ÷ 1.333333333)
Range
0 to 191.25 °
Unit
°

In testing for 2020 to 2026.

Knock retard cylinder 3 SFHEV_KNOCK_RETARD_CYL_3

  • Request21 19
  • Service 21PID 19
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 184 to 191 of the reply, 8 bits.

Formula
(val × 0.75 − 191.25)
Range
-191.25 to 0 °
Unit
°

In testing for 2020 to 2026.

Knock retard cylinder 3, alternate SFHEV_KNOCK_RETARD_3_E019

  • Request22 E0 19
  • Service 22DID E019
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 184 to 191 of the reply, 8 bits.

Formula
(val × 0.75 − 191.25)
Range
-191.25 to 0 °
Unit
°

In testing for 2020 to 2026.

Knock retard cylinder 3, alternate SFHEV_KNOCK_RETARD_CYL_3_ALT

  • Request21 0A
  • Service 21PID 0A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 176 to 183 of the reply, 8 bits.

Formula
(val ÷ 1.333333333)
Range
0 to 191.25 °
Unit
°

In testing for 2020 to 2026.

Knock retard cylinder 4 SFHEV_KNOCK_RETARD_CYL_4

  • Request21 19
  • Service 21PID 19
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 192 to 199 of the reply, 8 bits.

Formula
(val × 0.75 − 191.25)
Range
-191.25 to 0 °
Unit
°

In testing for 2020 to 2026.

Knock retard cylinder 4, alternate SFHEV_KNOCK_RETARD_4_E019

  • Request22 E0 19
  • Service 22DID E019
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 192 to 199 of the reply, 8 bits.

Formula
(val × 0.75 − 191.25)
Range
-191.25 to 0 °
Unit
°

In testing for 2020 to 2026.

Knock retard cylinder 4, alternate SFHEV_KNOCK_RETARD_CYL_4_ALT

  • Request21 0A
  • Service 21PID 0A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 184 to 191 of the reply, 8 bits.

Formula
(val ÷ 1.333333333)
Range
0 to 191.25 °
Unit
°

In testing for 2020 to 2026.

Knock retard, cylinder 1 SFHEV_KNOCK_RETARD_1Confirmed

  • Request22 E0 0A
  • Service 22DID E00A
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2020 to 2024, 2026

Example reply from a 2025 Hyundai Santa Fe Hybrid.

Bits 96 to 103 of the reply, 8 bits. The value is signed.

0x00 = 0 → (0 ÷ 5) = 0 °

Formula
(val ÷ 5)
Range
-25 to 25 °
Unit
°

Confirmed for 2025. In testing for 2020 to 2024, 2026.

Knock retard, cylinder 2 SFHEV_KNOCK_RETARD_2Confirmed

  • Request22 E0 0A
  • Service 22DID E00A
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2020 to 2024, 2026

Example reply from a 2025 Hyundai Santa Fe Hybrid.

Bits 104 to 111 of the reply, 8 bits. The value is signed.

0x00 = 0 → (0 ÷ 5) = 0 °

Formula
(val ÷ 5)
Range
-25 to 25 °
Unit
°

Confirmed for 2025. In testing for 2020 to 2024, 2026.

Knock retard, cylinder 3 SFHEV_KNOCK_RETARD_3Confirmed

  • Request22 E0 0A
  • Service 22DID E00A
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2020 to 2024, 2026

Example reply from a 2025 Hyundai Santa Fe Hybrid.

Bits 112 to 119 of the reply, 8 bits. The value is signed.

0x00 = 0 → (0 ÷ 5) = 0 °

Formula
(val ÷ 5)
Range
-25 to 25 °
Unit
°

Confirmed for 2025. In testing for 2020 to 2024, 2026.

Knock retard, cylinder 4 SFHEV_KNOCK_RETARD_4Confirmed

  • Request22 E0 0A
  • Service 22DID E00A
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2020 to 2024, 2026

Example reply from a 2025 Hyundai Santa Fe Hybrid.

Bits 120 to 127 of the reply, 8 bits. The value is signed.

0x00 = 0 → (0 ÷ 5) = 0 °

Formula
(val ÷ 5)
Range
-25 to 25 °
Unit
°

Confirmed for 2025. In testing for 2020 to 2024, 2026.

Lock switch SFHEV_LOCK_SWITCH

  • Request21 C0
  • Service 21PID C0
  • Module7E5
  • Every250 ms
  • Testing

Bit 151 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2020 to 2026.

Long term fuel trim (bank 1) LONGFT1SAE J1979Confirmed

  • Request01 07
  • Service 01PID 07
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 100 ÷ 128 − 100)
Range
-100 to 99.2 %
Unit
%

Confirmed for 2021, 2023. Supported for 2022, 2024 to 2025.

Long term secondary O2 sensor fuel trim (bank 1) LGSO2FT1SAE J1979Confirmed

  • Request01 56
  • Service 01PID 56
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 100 ÷ 128 − 100)
Range
-100 to 99.22 %
Unit
%

Confirmed for 2021, 2023. Supported for 2025.

Main injection volume SFHEV_MAIN_INJECTION_QTY

  • Request21 07
  • Service 21PID 07
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 96 to 103 of the reply, 8 bits.

Formula
(val × 0.392156863)
Range
0 to 100 L
Unit
L

In testing for 2020 to 2026.

Malfunction indicator SFHEV_MALFUNCTION_INDICATOR

  • Request21 C0
  • Service 21PID C0
  • Module7E5
  • Every250 ms
  • Testing

Bit 175 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2020 to 2026.

Mass air flow rate SFHEV_MAF_RATE

  • Request22 E0 10
  • Service 22DID E010
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 208 to 215 of the reply, 8 bits. The bytes are in little-endian order.

Formula
(val × 0.04239)
Range
0 to 10.8
Unit
Raw value

In testing for 2020 to 2026.

Max adaptation value for lower mechanical stop of the boost pressure actuator during engine running SFHEV_MAX_ADPT_LO_MECH_STOP_P

  • Request21 19
  • Service 21PID 19
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 480 to 495 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val × 1.53 ÷ 10000)
Range
0 to 10.02 V
Unit
V

In testing for 2020 to 2026.

Max adaptation value for lower mechanical stop of the boost pressure actuator during engine stop SFHEV_MAX_ADPT_LO_MECH_P

  • Request21 19
  • Service 21PID 19
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 464 to 479 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val × 1.53 ÷ 10000)
Range
0 to 10.02 V
Unit
V

In testing for 2020 to 2026.

Min adaptation value for lower mechanical stop of the boost pressure actuator during engine running SFHEV_MIN_ADPT_LO_MECH_STOP_P

  • Request21 19
  • Service 21PID 19
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 512 to 527 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val × 1.53 ÷ 10000)
Range
0 to 10.02 V
Unit
V

In testing for 2020 to 2026.

Min adaptation value for lower mechanical stop of the boost pressure actuator during engine stop SFHEV_MIN_ADPT_LO_MECH_P

  • Request21 19
  • Service 21PID 19
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 496 to 511 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val × 1.53 ÷ 10000)
Range
0 to 10.02 V
Unit
V

In testing for 2020 to 2026.

Misfires current total SFHEV_MIS_CURRENT_TOT

  • Request21 08
  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 584 to 591 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2020 to 2026.

Misfires current, cylinder 1 SFHEV_MIS_CURRENT_1

  • Request21 08
  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 536 to 543 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2020 to 2026.

Misfires current, cylinder 2 SFHEV_MIS_CURRENT_2

  • Request21 08
  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 544 to 551 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2020 to 2026.

Misfires current, cylinder 3 SFHEV_MIS_CURRENT_3

  • Request21 08
  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 552 to 559 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2020 to 2026.

Misfires current, cylinder 4 SFHEV_MIS_CURRENT_4

  • Request21 08
  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 560 to 567 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2020 to 2026.

Misfires current, cylinder 5 SFHEV_MIS_CURRENT_5

  • Request21 08
  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 568 to 575 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2020 to 2026.

Misfires current, cylinder 6 SFHEV_MIS_CURRENT_6

  • Request21 08
  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 576 to 583 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2020 to 2026.

Misfires harmful for catalyst, cylinder 1 SFHEV_MIS_HARMFUL_CAT_1

  • Request22 E0 1D
  • Service 22DID E01D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 160 to 175 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2026.

Misfires harmful for catalyst, cylinder 2 SFHEV_MIS_HARMFUL_CAT_2

  • Request22 E0 1D
  • Service 22DID E01D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 176 to 191 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2026.

Misfires harmful for catalyst, cylinder 3 SFHEV_MIS_HARMFUL_CAT_3

  • Request22 E0 1D
  • Service 22DID E01D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 192 to 207 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2026.

Misfires harmful for catalyst, cylinder 4 SFHEV_MIS_HARMFUL_CAT_4

  • Request22 E0 1D
  • Service 22DID E01D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 208 to 223 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2026.

Misfires, current, cylinder 1 SFHEV_MISFIRES_C1_CUR

  • Request22 E0 0D
  • Service 22DID E00D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 48 to 63 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2026.

Misfires, current, cylinder 2 SFHEV_MISFIRES_C2_CUR

  • Request22 E0 0D
  • Service 22DID E00D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 64 to 79 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2026.

Misfires, current, cylinder 3 SFHEV_MISFIRES_C3_CUR

  • Request22 E0 0D
  • Service 22DID E00D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 80 to 95 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2026.

Misfires, current, cylinder 4 SFHEV_MISFIRES_C4_CUR

  • Request22 E0 0D
  • Service 22DID E00D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 96 to 111 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2026.

Misfires, cylinder 1 SFHEV_MIS_1_7E0

  • Request22 E0 1D
  • Service 22DID E01D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 32 to 47 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2026.

Misfires, cylinder 2 SFHEV_MIS_2_7E0

  • Request22 E0 1D
  • Service 22DID E01D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 48 to 63 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2026.

Misfires, cylinder 3 SFHEV_MIS_3_7E0

  • Request22 E0 1D
  • Service 22DID E01D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 64 to 79 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2026.

Misfires, cylinder 4 SFHEV_MIS_4_7E0

  • Request22 E0 1D
  • Service 22DID E01D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 80 to 95 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2026.

Motor-driven power steering current SFHEV_MDPS_MOTOR_CURRENTConfirmed

  • Request22 01 01
  • Service 22DID 0101
  • Module7D4 → 7DC
  • Every5 s
  • Testing for 2020 to 2024, 2026

Example reply from a 2025 Hyundai Santa Fe Hybrid.

Bits 88 to 95 of the reply, 8 bits. The value is signed.

0x00 = 0 → 0 A

Formula
val
Range
-128 to 127 A
Unit
A

Confirmed for 2025. In testing for 2020 to 2024, 2026.

Niro_airbag h/wire duty SFHEV_AIRBAG_H_WIRE

  • Request21 05
  • Service 21PID 05
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 176 to 183 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2020 to 2024, 2026. Not supported for 2025.

Niro_bms ignition SFHEV_BMS_IGN

  • Request21 01
  • Service 21PID 01
  • Module7E4 → 7EC
  • Every5 s
  • Testing

Bit 405 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2020 to 2026.

Niro_bms main relay SFHEV_BMS_MAIN_RELAY

  • Request21 01
  • Service 21PID 01
  • Module7E4 → 7EC
  • Every5 s
  • Testing

Bit 79 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2020 to 2026.

Niro_isolation resistance SFHEV_ISOLATION_RES

  • Request21 01
  • Service 21PID 01
  • Module7E4 → 7EC
  • Every5 s
  • Testing

Bits 456 to 471 of the reply, 16 bits.

Formula
val
Range
0 to 65535 kΩ
Unit
kΩ

In testing for 2020 to 2026.

Niro_maximum deterioration SFHEV_MAX

  • Request21 05
  • Service 21PID 05
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 200 to 215 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 6553 %
Unit
%

In testing for 2020 to 2024, 2026. Not supported for 2025.

Niro_maximum deterioration cell no. SFHEV_MAX_DETERIORATION

  • Request21 05
  • Service 21PID 05
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 216 to 223 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2020 to 2024, 2026. Not supported for 2025.

Niro_minimum deterioration SFHEV_MIN

  • Request21 05
  • Service 21PID 05
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 224 to 239 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 6553 %
Unit
%

In testing for 2020 to 2024, 2026. Not supported for 2025.

Niro_minimum deterioration cell no. SFHEV_MIN_DETERIORATION

  • Request21 05
  • Service 21PID 05
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 240 to 247 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2020 to 2024, 2026. Not supported for 2025.

Niro_operating time SFHEV_OP_TIME

  • Request21 01
  • Service 21PID 01
  • Module7E4 → 7EC
  • Every5 s
  • Testing

Bits 368 to 399 of the reply, 32 bits.

Formula
(val ÷ 3600)
Range
0 to 1193046
Unit
Raw value

In testing for 2020 to 2026.

Number of quick charging SFHEV_NUM_QUICK_CHG

  • Request22 01 11
  • Service 22DID 0111
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 64 to 95 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2020 to 2026.

Number of standard charging SFHEV_NUM_STANDARD_CHG

  • Request22 01 11
  • Service 22DID 0111
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 32 to 63 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2020 to 2026.

Oil pump PWM SFHEV_OIL_PMP_PWM

  • Request22 ED 13
  • Service 22DID ED13
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 71 of the reply.

Formula
(val × 20 ÷ 51)
Range
0 to 0.392
Unit
Off or on

In testing for 2020 to 2026.

Output speed SFHEV_OUTPUT_SPEED

  • Request21 A0
  • Service 21PID A0
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 88 to 103 of the reply, 16 bits.

Formula
(val ÷ 4)
Range
0 to 16383.75 rpm
Unit
rpm

In testing for 2020 to 2024, 2026. Not supported for 2025.

Overheat protection, active SFHEV_OVERHEAT_PROTECTION

  • Request22 E0 14
  • Service 22DID E014
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 132 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2020 to 2026.

Oxygen sensor 1 bank 1 SFHEV_OXYGEN_SENSOR_11

  • Request21 02
  • Service 21PID 02
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
(val × 0.00521 − 0.2)
Range
-0.2 to 1.12 V
Unit
V

In testing for 2020 to 2026.

Oxygen sensor 2 bank 1 SFHEV_OXYGEN_SENSOR_21

  • Request21 02
  • Service 21PID 02
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 48 to 55 of the reply, 8 bits.

Formula
(val × 0.00521 − 0.2)
Range
-0.2 to 1.12 V
Unit
V

In testing for 2020 to 2026.

Parking sensor rear center left level SFHEV_PARKING_SENS_REAR

  • Request22 B0 09
  • Service 22DID B009
  • Module7A0 → 7A8
  • Every1 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2020 to 2026.

Parking sensor rear center right level SFHEV_PARKING_SENS_REAR_CENTER

  • Request22 B0 09
  • Service 22DID B009
  • Module7A0 → 7A8
  • Every1 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2020 to 2026.

Pilot injection volume SFHEV_PILOT_INJECTION_QTY

  • Request21 07
  • Service 21PID 07
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 104 to 119 of the reply, 16 bits.

Formula
val
Range
0 to 65535 L
Unit
L

In testing for 2020 to 2026.

Post injection volume SFHEV_POST_INJECTION_QTY

  • Request21 07
  • Service 21PID 07
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 128 to 143 of the reply, 16 bits.

Formula
val
Range
0 to 65535 L
Unit
L

In testing for 2020 to 2026.

Pressure sensor SFHEV_PRESSURE_SENSOR

  • Request21 C0
  • Service 21PID C0
  • Module7E5
  • Every250 ms
  • Testing

Bits 176 to 183 of the reply, 8 bits.

Formula
(val ÷ 4)
Range
0 to 63.75 bar
Unit
bar

In testing for 2020 to 2026.

Rail pressure control valve SFHEV_RAIL_P_CTRL_VLV

  • Request22 ED 01
  • Service 22DID ED01
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bit 55 of the reply.

Formula
(val × 20 ÷ 51)
Range
0 to 0.3921
Unit
Off or on

In testing for 2020 to 2026.

Regeneration demand counter by soot load SFHEV_REGEN_DEMAND_CNT

  • Request22 ED 03
  • Service 22DID ED03
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 320 to 327 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2020 to 2026.

Requested torque SFHEV_REQUESTED_TORQUE

  • Request21 14
  • Service 21PID 14
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 176 to 191 of the reply, 16 bits.

Formula
(val × 0.001526)
Range
0 to 100 %
Unit
%

In testing for 2020 to 2026.

Requested torque limitation from traction control SFHEV_REQ_TQ_LIM_TRACTION

  • Request22 ED 06
  • Service 22DID ED06
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 120 to 127 of the reply, 8 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

In testing for 2020 to 2026.

Short term fuel trim (bank 1) SHRTFT1SAE J1979Confirmed

Correction being used by the closed-loop fuel algorithm.

Pelican can show this parameter as the short term fuel trim.

  • Request01 06
  • Service 01PID 06
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 100 ÷ 128 − 100)
Range
-100 to 99.2 %
Unit
%

Confirmed for 2021, 2023, 2025. Supported for 2022, 2024.

Short term secondary O2 sensor fuel trim (bank 1) STSO2FT1SAE J1979Confirmed

  • Request01 55
  • Service 01PID 55
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 100 ÷ 128 − 100)
Range
-100 to 99.22 %
Unit
%

Confirmed for 2021, 2023. Supported for 2025.

Successful regeneration state SFHEV_SUCCESSFUL_REGEN_ST

  • Request22 ED 03
  • Service 22DID ED03
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 424 to 431 of the reply, 8 bits.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2020 to 2026.

Throttle position #1 SFHEV_THROTTLE_POSITION__1

  • Request21 14
  • Service 21PID 14
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 48 to 63 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
(val × 0.0244140625)
Range
-800 to 799 %
Unit
%

In testing for 2020 to 2026.

Throttle position #2 SFHEV_THROTTLE_POSITION__2

  • Request21 14
  • Service 21PID 14
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 64 to 79 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
(val × 0.0244140625)
Range
-800 to 799 %
Unit
%

In testing for 2020 to 2026.

Timing advance SPARKADVSAE J1979Confirmed

Ignition timing spark advance for the first cylinder. Measured in degrees before dead center. Minus is degrees before dead center, positive is degrees after.

  • Request01 0E
  • Service 01PID 0E
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 2 − 64)
Range
-64 to 63.5 °
Unit
°

Confirmed for 2021, 2023. Supported for 2022, 2024 to 2025.

Timing advance #1 SFHEV_TIMING_ADVANCE_1

  • Request21 13
  • Service 21PID 13
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 32 to 39 of the reply, 8 bits. The value is signed.

Formula
(val × 0.75)
Range
-96 to 95.25 °
Unit
°

In testing for 2020 to 2026.

Timing advance #2 SFHEV_TIMING_ADVANCE_2

  • Request21 13
  • Service 21PID 13
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 40 to 47 of the reply, 8 bits. The value is signed.

Formula
(val × 0.75)
Range
-96 to 95.25 °
Unit
°

In testing for 2020 to 2026.

Timing advance #3 SFHEV_TIMING_ADVANCE_3

  • Request21 13
  • Service 21PID 13
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 48 to 55 of the reply, 8 bits. The value is signed.

Formula
(val × 0.75)
Range
-96 to 95.25 °
Unit
°

In testing for 2020 to 2026.

Timing advance #4 SFHEV_TIMING_ADVANCE_4

  • Request21 13
  • Service 21PID 13
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 56 to 63 of the reply, 8 bits. The value is signed.

Formula
(val × 0.75)
Range
-96 to 95.25 °
Unit
°

In testing for 2020 to 2026.

Torque converter slip SFHEV_TORQUE_CONVERTER_SLIP

  • Request21 A0
  • Service 21PID A0
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 128 to 143 of the reply, 16 bits.

Formula
(val ÷ 4 − 512)
Range
-512 to 15871.75 rpm
Unit
rpm

In testing for 2020 to 2024, 2026. Not supported for 2025.

Torque converter slip SFHEV_TORQUE_CONVERTER_SLIP_7E1

  • Request22 01 A0
  • Service 22DID 01A0
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 128 to 143 of the reply, 16 bits.

Formula
(val ÷ 4 − 512)
Range
-512 to 15871.75 rpm
Unit
rpm

In testing for 2020 to 2026.

Torque converter slip SFHEV_TQ_CONV_SLIP

  • Request21 A0
  • Service 21PID A0
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 104 to 119 of the reply, 16 bits.

Formula
(val ÷ 4 − 512)
Range
-512 to 15871.75 rpm
Unit
rpm

In testing for 2020 to 2026.

Torque, actual SFHEV_TQ_ACT

  • Request21 05
  • Service 21PID 05
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 64 to 79 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val × 61 ÷ 40000)
Range
0 to 99.94 %
Unit
%

In testing for 2020 to 2026.

Total sulfur mass SFHEV_TOT_SULFUR_MASS

  • Request22 ED 29
  • Service 22DID ED29
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 15259 ÷ 100000)
Range
0 to 9999
Unit
Raw value

In testing for 2020 to 2026.

Transmission fluid temperature SFHEV_ATF_T_7E0

  • Request21 A0
  • Service 21PID A0
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 264 to 271 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2020 to 2026.

Turbine speed SFHEV_TURBINE_SPEED

  • Request21 A0
  • Service 21PID A0
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 72 to 87 of the reply, 16 bits.

Formula
(val ÷ 4)
Range
0 to 16383.75 rpm
Unit
rpm

In testing for 2020 to 2024, 2026. Not supported for 2025.

Turbo boost pressure SFHEV_TB_PRES

  • Request22 E0 21
  • Service 22DID E021
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 56 to 71 of the reply, 16 bits.

Formula
(val × 0.008291)
Range
0 to 543 kPa
Unit
kPa

In testing for 2020 to 2024, 2026. Not supported for 2025.

Turbo boost pressure SFHEV_TURBO_BOOST_P

  • Request21 19
  • Service 21PID 19
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 64 to 79 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val × 829.1 ÷ 10000)
Range
0 to 5433
Unit
Raw value

In testing for 2020 to 2026.

Turbo boost pressure SFHEV_TURBO_BOOST_P_7E0

  • Request21 21
  • Service 21PID 21
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 56 to 71 of the reply, 16 bits.

Formula
(val × 0.008291)
Range
0 to 543
Unit
Number

In testing for 2020 to 2026.

Type of fuel currently being used by the vehicle FUEL_TYPSAE J1979Confirmed

  • Request01 51
  • Service 01PID 51
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
1GASGasoline/petrol
2METHMethanol
3ETHEthanol
4DSLDiesel
5LPGLiquefied petroleum gas
6CNGCompressed natural gas
7PROPPropane
8ELECBattery/electric
9BI_GASBi-fuel vehicle using gasoline/petrol
10BI_METHBi-fuel vehicle using methanol
11BI_ETHBi-fuel vehicle using ethanol
12BI_LPGBi-fuel vehicle using LPG
13BI_CNGBi-fuel vehicle using CNG
14BI_PROPBi-fuel vehicle using propane
15BI_ELECBi-fuel vehicle using battery
16BI_MIXBi-fuel vehicle using battery and combustion engine for propulsion
17HYB_GASHybrid vehicle using gasoline engine for propulsion
18HYB_ETHHybrid vehicle using gasoline engine on ethanol for propulsion
19HYB_DSLHybrid vehicle using diesel engine for propulsion
20HYB_ELECHybrid vehicle using battery for propulsion
21HYB_MIXHybrid vehicle using battery and combustion engine for propulsion
22HYB_REGHybrid vehicle in regeneration mode
23BI_DSLBi-fuel vehicle using diesel
24BI_NGBi-fuel vehicle using natural gas
25BI_DSLBi-fuel vehicle using diesel
26NGNatural gas
27DSL_CNGDual fuel vehicle using diesel and CNG
28DSL_LNGDual fuel vehicle using diesel and LNG
29FC_H2Fuel cell utilizing hydrogen
30HICE_HHOHydrogen Internal Combustion Engine
31KEROKerosene
32HFOHeavy Fuel Oil

Confirmed for 2021, 2023. Supported for 2025.

Variable valve timing temperature SFHEV_CVVT_T

Continuously variable valve timing temperature.

  • Request21 18
  • Service 21PID 18
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 272 to 279 of the reply, 8 bits.

Formula
(val − 48)
Range
-48 to 207 °C
Unit
°C

In testing for 2020 to 2024, 2026. Not supported for 2025.

Waste gate duty SFHEV_WASTE_GATE_DUTY

  • Request21 21
  • Service 21PID 21
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 408 to 423 of the reply, 16 bits.

Formula
(val × 0.00305176)
Range
0 to 199 %
Unit
%

In testing for 2020 to 2026.

Waste gate duty SFHEV_WG_DUTY

  • Request22 E0 21
  • Service 22DID E021
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 408 to 423 of the reply, 16 bits.

Formula
(val × 0.00305176)
Range
0 to 199 %
Unit
%

In testing for 2020 to 2024, 2026. Not supported for 2025.

Waste gate position SFHEV_WASTE_GATE_POS

  • Request21 21
  • Service 21PID 21
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 424 to 439 of the reply, 16 bits.

Formula
(val × 0.00610352)
Range
0 to 399 %
Unit
%

In testing for 2020 to 2026.

Waste gate position SFHEV_WG_POS

  • Request22 E0 21
  • Service 22DID E021
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 424 to 439 of the reply, 16 bits.

Formula
(val × 0.00610352)
Range
0 to 399 %
Unit
%

In testing for 2020 to 2024, 2026. Not supported for 2025.

Waste gate set point SFHEV_WG_SP

  • Request22 E0 21
  • Service 22DID E021
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 440 to 455 of the reply, 16 bits.

Formula
(val × 0.00610352)
Range
0 to 399 %
Unit
%

In testing for 2020 to 2024, 2026. Not supported for 2025.

Waste gate target SFHEV_WASTE_GATE_TGT

  • Request21 21
  • Service 21PID 21
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 440 to 455 of the reply, 16 bits.

Formula
(val × 0.00610352)
Range
0 to 399 %
Unit
%

In testing for 2020 to 2026.

Waste gate voltage SFHEV_WG_V

  • Request22 E0 21
  • Service 22DID E021
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 392 to 407 of the reply, 16 bits.

Formula
(val × 0.000152588)
Range
0 to 9.99 V
Unit
V

In testing for 2020 to 2024, 2026. Not supported for 2025.

Wastegate control PWM, wastegate actuator SFHEV_WASTEGATE_CTRL_PWM

  • Request21 19
  • Service 21PID 19
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 416 to 431 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
(val × 100 ÷ 32767)
Range
-100 to 100 %
Unit
%

In testing for 2020 to 2026.

Wastegate position target, wastegate actuator SFHEV_WASTEGATE_POS_TGT

  • Request21 19
  • Service 21PID 19
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 448 to 463 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
(val × 200 ÷ 32767)
Range
-200 to 200 %
Unit
%

In testing for 2020 to 2026.

Wastegate position, wastegate actuator SFHEV_WASTEGATE_POS

  • Request21 19
  • Service 21PID 19
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 432 to 447 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
(val × 200 ÷ 32767)
Range
-200 to 200 %
Unit
%

In testing for 2020 to 2026.

Wide open throttle SFHEV_WIDE_OPEN_THROTTLEConfirmed

  • Request22 E0 04
  • Service 22DID E004
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2020 to 2024, 2026

Example reply from a 2025 Hyundai Santa Fe Hybrid.

Bits 72 to 79 of the reply, 8 bits.

0x00 = 0 → 0

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2025. In testing for 2020 to 2024, 2026.

Engine › Internal

EGR Temperature Sensor A (Bank 1, Sensor 1) supported? EGRTA_SUPSAE J1979Confirmed

  • Request01 6B
  • Service 01PID 6B
  • Module7E0 → 7E8
  • Every250 ms

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2021, 2023. Supported for 2025.

EGR Temperature Sensor A (Bank 1, Sensor 1) Wide Range supported? EGRTA_WR_SUPSAE J1979Confirmed

  • Request01 6B
  • Service 01PID 6B
  • Module7E0 → 7E8
  • Every250 ms

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2021, 2023. Supported for 2025.

EGR Temperature Sensor B (Bank 2, Sensor 1) supported? EGRTB_SUPSAE J1979Confirmed

  • Request01 6B
  • Service 01PID 6B
  • Module7E0 → 7E8
  • Every250 ms

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2021, 2023. Supported for 2025.

EGR Temperature Sensor B (Bank 2, Sensor 1) Wide Range supported? EGRTB_WR_SUPSAE J1979Confirmed

  • Request01 6B
  • Service 01PID 6B
  • Module7E0 → 7E8
  • Every250 ms

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2021, 2023. Supported for 2025.

EGR Temperature Sensor C (Bank 1, Sensor 2) supported? EGRTC_SUPSAE J1979Confirmed

  • Request01 6B
  • Service 01PID 6B
  • Module7E0 → 7E8
  • Every250 ms

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2021, 2023. Supported for 2025.

EGR Temperature Sensor C (Bank 1, Sensor 2) Wide Range supported? EGRTC_WR_SUPSAE J1979Confirmed

  • Request01 6B
  • Service 01PID 6B
  • Module7E0 → 7E8
  • Every250 ms

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2021, 2023. Supported for 2025.

EGR Temperature Sensor D (Bank 2, Sensor 2) supported? EGRTD_SUPSAE J1979Confirmed

  • Request01 6B
  • Service 01PID 6B
  • Module7E0 → 7E8
  • Every250 ms

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2021, 2023. Supported for 2025.

EGR Temperature Sensor D (Bank 2, Sensor 2) Wide Range supported? EGRTD_WR_SUPSAE J1979Confirmed

  • Request01 6B
  • Service 01PID 6B
  • Module7E0 → 7E8
  • Every250 ms

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2021, 2023. Supported for 2025.

Is ECT sensor 1 supported? ECT_1_SUPSAE J1979Confirmed

  • Request01 67
  • Service 01PID 67
  • Module7E0 → 7E8
  • Every1 s

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Number

Confirmed for 2021, 2023, 2025.

Is ECT sensor 2 supported? ECT_2_SUPSAE J1979Confirmed

  • Request01 67
  • Service 01PID 67
  • Module7E0 → 7E8
  • Every1 s

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
Number

Confirmed for 2021, 2023, 2025.

Engine › Misfires

Emission-relevant misfires, cylinder #1 SFHEV_MIS_CNT_EMIS_1

  • Request21 0D
  • Service 21PID 0D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 48 to 63 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2026.

Emission-relevant misfires, cylinder #2 SFHEV_MIS_CNT_EMIS_2

  • Request21 0D
  • Service 21PID 0D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 64 to 79 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2026.

Emission-relevant misfires, cylinder #3 SFHEV_MIS_CNT_EMIS_3

  • Request21 0D
  • Service 21PID 0D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 80 to 95 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2026.

Emission-relevant misfires, cylinder #4 SFHEV_MIS_CNT_EMIS_4

  • Request21 0D
  • Service 21PID 0D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 96 to 111 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2026.

Misfires harmful for catalyst cylinder 1 SFHEV_MIS_CAT_1

  • Request21 1D
  • Service 21PID 1D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 160 to 175 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2026.

Misfires harmful for catalyst cylinder 2 SFHEV_MIS_CAT_2

  • Request21 1D
  • Service 21PID 1D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 176 to 191 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2026.

Misfires harmful for catalyst cylinder 3 SFHEV_MIS_CAT_3

  • Request21 1D
  • Service 21PID 1D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 192 to 207 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2026.

Misfires harmful for catalyst cylinder 4 SFHEV_MIS_CAT_4

  • Request21 1D
  • Service 21PID 1D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 208 to 223 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2026.

Misfires total counter, all cylinders SFHEV_MIS_CNT_ALL

  • Request21 0D
  • Service 21PID 0D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 432 to 447 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2026.

Misfires total counter, cylinder #1 SFHEV_MIS_CNT_1

  • Request21 0D
  • Service 21PID 0D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 176 to 191 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2026.

Misfires total counter, cylinder #2 SFHEV_MIS_CNT_2

  • Request21 0D
  • Service 21PID 0D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 192 to 207 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2026.

Misfires total counter, cylinder #3 SFHEV_MIS_CNT_3

  • Request21 0D
  • Service 21PID 0D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 208 to 223 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2026.

Misfires total counter, cylinder #4 SFHEV_MIS_CNT_4

  • Request21 0D
  • Service 21PID 0D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 224 to 239 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2026.

Misfires, cylinder 1 SFHEV_MIS_1

  • Request21 1D
  • Service 21PID 1D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 32 to 47 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2026.

Misfires, cylinder 2 SFHEV_MIS_2

  • Request21 1D
  • Service 21PID 1D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 48 to 63 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2026.

Misfires, cylinder 3 SFHEV_MIS_3

  • Request21 1D
  • Service 21PID 1D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 64 to 79 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2026.

Misfires, cylinder 4 SFHEV_MIS_4

  • Request21 1D
  • Service 21PID 1D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 80 to 95 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2026.

Engine › OxygenSensors

02S Bank 1, Sensor 1 present O2S11_EXISTSSAE J1979Confirmed

  • Request01 13
  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2025. Supported for 2021 to 2024.

02S Bank 1, Sensor 2 present O2S12_EXISTSSAE J1979Confirmed

  • Request01 13
  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2025. Supported for 2021 to 2024.

02S Bank 1, Sensor 3 present O2S13_EXISTSSAE J1979Confirmed

  • Request01 13
  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2025. Supported for 2021 to 2024.

02S Bank 1, Sensor 4 present O2S14_EXISTSSAE J1979Confirmed

  • Request01 13
  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2025. Supported for 2021 to 2024.

02S Bank 2, Sensor 1 present O2S21_EXISTSSAE J1979Confirmed

  • Request01 13
  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2025. Supported for 2021 to 2024.

02S Bank 2, Sensor 2 present O2S22_EXISTSSAE J1979Confirmed

  • Request01 13
  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2025. Supported for 2021 to 2024.

02S Bank 2, Sensor 3 present O2S23_EXISTSSAE J1979Confirmed

  • Request01 13
  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2025. Supported for 2021 to 2024.

02S Bank 2, Sensor 4 present O2S24_EXISTSSAE J1979Confirmed

  • Request01 13
  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2025. Supported for 2021 to 2024.

Lambda value, Equivalence Ratio Bank 1, Sensor 1 LAMBDA11_CURRENTSAE J1979Confirmed

Pelican can show this parameter as the O2 lambda.

  • Request01 34
  • Service 01PID 34
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 32768)
Range
0 to 1.99
Unit
Number

Confirmed for 2023, 2025. Supported for 2021, 2024.

Wide Range O2S Current, O2 Sensor Bank 1, Sensor 1 O2S11_CURRENTSAE J1979Confirmed

  • Request01 34
  • Service 01PID 34
  • Module7E0 → 7E8
  • Every250 ms

Bits 16 to 31 of the reply, 16 bits.

Formula
(val ÷ 256 − 128)
Range
-128 to 127.996 mA
Unit
mA

Confirmed for 2023, 2025. Supported for 2021, 2024.

Engine › Unknown

Engine status byte SFHEV_E004_BYTE0Confirmed

  • Request22 E0 04
  • Service 22DID E004
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2020 to 2024, 2026

Example reply from a 2025 Hyundai Santa Fe Hybrid.

Bits 0 to 7 of the reply, 8 bits.

0x4D = 77 → 77

Formula
val
Range
0 to 100
Unit
Number

Confirmed for 2025. In testing for 2020 to 2024, 2026.

Keyboard shortcuts

jk/↓↑
Move down or up through a list or a grid.
hl/←→
Move across a row or between cards.
Enter
Open the focused link.
f
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.