Engine parameters
The Hyundai Santa Cruz has 107 engine parameters.
● Confirmed◆ In testing○ Supported× Not supported
4WD calculated clutch power SANTA_CRUZ_AWD_CALC_CLU_POWERConfirmed
- Request
22 01 A3 - Service 22
DID 01A3 - Module
740 → 748 - Every
250 ms - Testing for 2021 to 2022, 2024, 2026
Bits 56 to 71 of the reply, 16 bits.
- Formula
(val × 39.062 ÷ 10000)- Range
- 0 to 255 kWh
- Unit
- kWh
Confirmed for 2023, 2025. In testing for 2021 to 2022, 2024, 2026.
4WD calculated engine power SANTA_CRUZ_AWD_CALC_ENG_POWERConfirmed
- Request
22 01 A3 - Service 22
DID 01A3 - Module
740 → 748 - Every
250 ms - Testing for 2021 to 2022, 2024, 2026
Example reply from a 2025 Hyundai Santa Cruz.
Bits 72 to 87 of the reply, 16 bits.
0x20CD = 8397 → (8397 × 9.766 ÷ 10000) = 8.20051 kWh
- Formula
(val × 9.766 ÷ 10000)- Range
- 0 to 64 kWh
- Unit
- kWh
Confirmed for 2023, 2025. In testing for 2021 to 2022, 2024, 2026.
4WD calculated, commanded torque SANTA_CRUZ_AWD_CALC_CMD_TQConfirmed
- Request
22 01 A1 - Service 22
DID 01A1 - Module
740 → 748 - Every
250 ms - Testing for 2021 to 2022, 2024, 2026
Example reply from a 2025 Hyundai Santa Cruz.
Bits 40 to 55 of the reply, 16 bits. The value is signed.
0x0000 = 0 → (0 ÷ 8) = 0 N·m
- Formula
(val ÷ 8)- Range
- -4096 to 4095.875 N·m
- Unit
- N·m
Confirmed for 2023, 2025. In testing for 2021 to 2022, 2024, 2026.
4WD clutch, actual pressure SANTA_CRUZ_AWD_CLU_ACT_PConfirmed
- Request
22 01 A1 - Service 22
DID 01A1 - Module
740 → 748 - Every
250 ms - Testing for 2021 to 2022, 2024, 2026
Bits 144 to 159 of the reply, 16 bits. The value is signed.
- Formula
(val × 19.53 ÷ 10000)- Range
- -63.99 to 63.99 bar
- Unit
- bar
Confirmed for 2023, 2025. In testing for 2021 to 2022, 2024, 2026.
4WD clutch, actual torque SANTA_CRUZ_AWD_CLU_ACT_TQConfirmed
- Request
22 01 A1 - Service 22
DID 01A1 - Module
740 → 748 - Every
250 ms - Testing for 2021 to 2022, 2024, 2026
Example reply from a 2025 Hyundai Santa Cruz.
Bits 128 to 143 of the reply, 16 bits. The value is signed.
0x0000 = 0 → (0 ÷ 8) = 0 N·m
- Formula
(val ÷ 8)- Range
- -4096 to 4095.875 N·m
- Unit
- N·m
Confirmed for 2023, 2025. In testing for 2021 to 2022, 2024, 2026.
4WD max clutch stress SANTA_CRUZ_AWD_MAX_CLU_STRESSConfirmed
- Request
22 01 A1 - Service 22
DID 01A1 - Module
740 → 748 - Every
250 ms - Testing for 2021 to 2022, 2024, 2026
Example reply from a 2025 Hyundai Santa Cruz.
Bits 88 to 103 of the reply, 16 bits.
0x113F = 4415 → (4415 × 19.531 ÷ 10000) = 8.622937 %
- Formula
(val × 19.531 ÷ 10000)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2023, 2025. In testing for 2021 to 2022, 2024, 2026.
4WD pump current SANTA_CRUZ_AWD_PMP_CURRENTConfirmed
- Request
22 01 A1 - Service 22
DID 01A1 - Module
740 → 748 - Every
250 ms - Testing for 2021 to 2022, 2024, 2026
Bits 112 to 127 of the reply, 16 bits. The value is signed.
- Formula
(val × 78.125 ÷ 10000)- Range
- -256 to 255 A
- Unit
- A
Confirmed for 2023, 2025. In testing for 2021 to 2022, 2024, 2026.
4WD pump PWM duty SANTA_CRUZ_AWD_PMP_PWM_DUTYConfirmed
- Request
22 01 A1 - Service 22
DID 01A1 - Module
740 → 748 - Every
250 ms - Testing for 2021 to 2022, 2024, 2026
Example reply from a 2025 Hyundai Santa Cruz.
Bits 56 to 71 of the reply, 16 bits. The value is signed.
0x0000 = 0 → (0 ÷ 10) = 0 %
- Formula
(val ÷ 10)- Range
- -3276.8 to 100 %
- Unit
- %
Confirmed for 2023, 2025. In testing for 2021 to 2022, 2024, 2026.
Absolute load value LOAD_ABSSAE J1979Confirmed
- Request
01 43 - Service 01
PID 43 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 25700 %
- Unit
- %
Confirmed for 2023, 2025. Supported for 2022, 2024.
Actual engine torque TQ_ACTSAE J1979Confirmed
- Request
01 62 - Service 01
PID 62 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 125)- Range
- -125 to 130 %
- Unit
- %
Confirmed for 2023.
Air conditioning pressure SANTA_CRUZ_AC_PConfirmed
- Request
22 E0 14 - Service 22
DID E014 - Module
7E0 → 7E8 - Every
1 s - Testing for 2021 to 2022, 2024, 2026
Example reply from a 2025 Hyundai Santa Cruz.
Bits 112 to 119 of the reply, 8 bits.
0x2C = 44 → (44 × 13.79) = 606.76 kPa
- Formula
(val × 13.79)- Range
- 0 to 3516.45 kPa
- Unit
- kPa
Confirmed for 2023, 2025. In testing for 2021 to 2022, 2024, 2026.
Air flow rate from mass air flow sensor MAFSAE J1979Confirmed
Pelican can show this parameter as the mass air flow.
- Request
01 10 - Service 01
PID 10 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655.35 g/s
- Unit
- g/s
Confirmed for 2025. Supported for 2024.
Automatic transmission fluid temperature SANTA_CRUZ_ATF_T_7E1Confirmed
Pelican can show this parameter as the transmission fluid temperature.
- Request
22 01 A0 - Service 22
DID 01A0 - Module
7E1 → 7E9 - Every
250 ms - Testing for 2021 to 2024, 2026
Example reply from a 2025 Hyundai Santa Cruz.
Bits 104 to 111 of the reply, 8 bits.
0x50 = 80 → (80 − 40) = 40 °C
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2025. In testing for 2021, 2024, 2026. Not supported for 2022 to 2023.
Barometric pressure BAROSAE J1979Confirmed
Normally obtained from one of a dedicated barometric sensor, a MAP sensor at key-on and during certain modes of driving, or inferred from a MAF sensor and other inputs during certain modes of driving. The control module reports BARO from whatever source it is derived from.
- Request
01 33 - Service 01
PID 33 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 kPa
- Unit
- kPa
Confirmed for 2023. Supported for 2022, 2024 to 2025.
Boost pressure upstream SANTA_CRUZ_BOOST_P_UP
- Request
22 E0 03 - Service 22
DID E003 - Module
7E0 → 7E8 - Every
1 s - Testing for 2021 to 2022, 2024, 2026
Bits 280 to 295 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val × 39 ÷ 500)- Range
- 0 to 5111
- Unit
- Raw value
In testing for 2021 to 2022, 2024, 2026. Supported for 2023, 2025.
Boost pressure upstream, desired SANTA_CRUZ_BOOST_P_UP_DES
- Request
22 E0 03 - Service 22
DID E003 - Module
7E0 → 7E8 - Every
1 s - Testing for 2021 to 2022, 2024, 2026
Bits 312 to 327 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val × 39 ÷ 500)- Range
- 0 to 5111
- Unit
- Raw value
In testing for 2021 to 2022, 2024, 2026. Supported for 2023, 2025.
Calculated engine load LOAD_PCTSAE J1979Confirmed
Represents the amount of work the engine is doing. Expected to reach 100% at wide open throttle/wide open pedal at any altitude, temperature or rpm for both naturally aspirated and boosted engines. If engine load is limited for powertrain protection e.g. engine/turbocharger protection, this value may not reach 100%. For hybrid vehicles, indicates the torque produced only by the internal combustion engine, not the torque being delivered by the entire powertrain. For electric vehicles, the meaning of this parameter is undefined.
Pelican can show this parameter as the engine load.
- Request
01 04 - Service 01
PID 04 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2022 to 2023, 2025. Supported for 2024.
Calculated oil temperature SANTA_CRUZ_CALC_OIL_TConfirmed
- Request
22 E0 11 - Service 22
DID E011 - Module
7E0 → 7E8 - Every
5 s - Testing for 2021 to 2022, 2024, 2026
Bits 304 to 311 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2023, 2025. In testing for 2021 to 2022, 2024, 2026.
Catalyst temperature bank 1, sensor 1 CATEMP11SAE J1979Confirmed
- Request
01 3C - Service 01
PID 3C - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10 − 40)- Range
- -40 to 6513.5 °C
- Unit
- °C
Confirmed for 2023. Supported for 2022, 2024 to 2025.
Catalyst temperature bank 1, sensor 2 CATEMP12SAE J1979Confirmed
- Request
01 3E - Service 01
PID 3E - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10 − 40)- Range
- -40 to 6513.5 °C
- Unit
- °C
Confirmed for 2023. Supported for 2022.
Commanded equivalence ratio EQ_RATSAE J1979Confirmed
Fuel systems that utilize conventional oxygen sensor display the inverse of the commanded open loop equivalence ratio (also known as lambda) while the fuel control system is in open loop. Will indicate 1.000 while in closed-loop fuel.
Pelican can show this parameter as the commanded lambda.
- Request
01 44 - Service 01
PID 44 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 2 ÷ 65535)- Range
- 0 to 1.99
- Unit
- Number
Confirmed for 2022 to 2023, 2025. Supported for 2024.
Commanded evaporative purge EVAP_PCTSAE J1979Confirmed
- Request
01 2E - Service 01
PID 2E - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2023. Supported for 2022, 2024 to 2025.
Commanded throttle actuator control TAC_PCTSAE J1979Confirmed
- Request
01 4C - Service 01
PID 4C - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2023.
Coolant fan PWM SANTA_CRUZ_CLT_FAN_PWMConfirmed
- Request
22 E0 14 - Service 22
DID E014 - Module
7E0 → 7E8 - Every
1 s - Testing for 2021 to 2022, 2024, 2026
Example reply from a 2025 Hyundai Santa Cruz.
Bits 88 to 103 of the reply, 16 bits.
0x4D09 = 19721 → (19721 × 15.21 ÷ 10000) = 29.995641 %
- Formula
(val × 15.21 ÷ 10000)- Range
- 0 to 99.67 %
- Unit
- %
Confirmed for 2023, 2025. In testing for 2021 to 2022, 2024, 2026.
Coverage driven length SANTA_CRUZ_COVERAGE_DRIVEN
- Request
22 E0 09 - Service 22
DID E009 - Module
7E0 → 7E8 - Every
30 s - Testing for 2021 to 2024, 2026
Bits 392 to 423 of the reply, 32 bits. The bytes are in little-endian order.
- Formula
(val ÷ 1000)- Range
- 0 to 4294967 km
- Unit
- km
In testing for 2021 to 2024, 2026. Supported for 2025.
Engine coolant temperature 1 ECT_1SAE J1979Confirmed
- Request
01 67 - Service 01
PID 67 - Module
7E0 → 7E8 - Every
1 s
Bits 8 to 15 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2023.
Engine coolant temperature 2 ECT_2SAE J1979Confirmed
- Request
01 67 - Service 01
PID 67 - Module
7E0 → 7E8 - Every
1 s
Bits 16 to 23 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2023.
Engine Friction - Percent Torque TQ_FRSAE J1979Confirmed
- Request
01 8E - Service 01
PID 8E - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 125)- Range
- -125 to 130 %
- Unit
- %
Confirmed for 2023.
Engine oil temperature SANTA_CRUZ_EOTConfirmed
- Request
22 E0 01 - Service 22
DID E001 - Module
7E0 → 7E8 - Every
5 s - Testing for 2021, 2026
Example reply from a 2025 Hyundai Santa Cruz.
Bits 272 to 279 of the reply, 8 bits.
0xBC = 188 → (188 × 3 ÷ 4 − 48) = 93 °C
- Formula
(val × 3 ÷ 4 − 48)- Range
- -48 to 143 °C
- Unit
- °C
Confirmed for 2022 to 2025. In testing for 2021, 2026.
Engine reference torque TQ_REFSAE J1979Confirmed
- Request
01 63 - Service 01
PID 63 - Module
7E0 → 7E8 - Every
86400 s
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 N·m
- Unit
- N·m
Confirmed for 2023.
Engine RPM RPMSAE J1979Confirmed
- Request
01 0C - Service 01
PID 0C - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4)- Range
- 0 to 16383.75 rpm
- Unit
- rpm
Confirmed for 2023, 2025. Supported for 2022, 2024.
Evap system vapor pressure EVAP_VPSAE J1979Confirmed
The pressure signal is normally obtained from a sensor located in the fuel tank or a sensor in an evaporative system vapor line.
- Request
01 32 - Service 01
PID 32 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 4000)- Range
- -8192 to 8191.75 kPa
- Unit
- kPa
Confirmed for 2023. Supported for 2022, 2024 to 2025.
Exhaust camshaft position SANTA_CRUZ_EXH_CAM_POSConfirmed
- Request
22 E0 20 - Service 22
DID E020 - Module
7E0 → 7E8 - Every
1 s - Testing for 2021 to 2022, 2024, 2026
Example reply from a 2025 Hyundai Santa Cruz.
Bits 88 to 103 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
0xC280 = -15744 → (-15744 ÷ 128) = -123 °
- Formula
(val ÷ 128)- Range
- -256 to 255 °
- Unit
- °
Confirmed for 2023, 2025. In testing for 2021 to 2022, 2024, 2026.
Exhaust gas temperature before gasoline particulate filter sensor 1 SANTA_CRUZ_EXH_GAS_T_BEFORE_GPF_1
- Request
22 E0 09 - Service 22
DID E009 - Module
7E0 → 7E8 - Every
30 s - Testing for 2021 to 2024, 2026
Bits 288 to 303 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val × 12 ÷ 125)- Range
- 0 to 6291 °C
- Unit
- °C
In testing for 2021 to 2024, 2026. Supported for 2025.
Exhaust gas temperature before gasoline particulate filter sensor 2 SANTA_CRUZ_EXH_GAS_T_BEFORE_GPF_2
- Request
22 E0 09 - Service 22
DID E009 - Module
7E0 → 7E8 - Every
30 s - Testing for 2021 to 2024, 2026
Bits 304 to 319 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val × 12 ÷ 125)- Range
- 0 to 6291 °C
- Unit
- °C
In testing for 2021 to 2024, 2026. Supported for 2025.
Fuel rail pressure FRPSAE J1979Confirmed
Fuel rail pressure at the engine when the reading is referenced to atmosphere (gage pressure).
- Request
01 23 - Service 01
PID 23 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 10)- Range
- 0 to 655350 kPa
- Unit
- kPa
Confirmed for 2023. Supported for 2022, 2024 to 2025.
Gasoline direct injection time bank a, 1 SANTA_CRUZ_GDI_IT_A1
- Request
22 E0 05 - Service 22
DID E005 - Module
7E0 → 7E8 - Every
1 s - Testing for 2021 to 2022, 2024, 2026
Bits 224 to 239 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 ms
- Unit
- ms
In testing for 2021 to 2022, 2024, 2026. Supported for 2023, 2025.
Gasoline direct injection time bank a, 2 SANTA_CRUZ_GDI_IT_A2
- Request
22 E0 05 - Service 22
DID E005 - Module
7E0 → 7E8 - Every
1 s - Testing for 2021 to 2022, 2024, 2026
Bits 240 to 255 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 ms
- Unit
- ms
In testing for 2021 to 2022, 2024, 2026. Supported for 2023, 2025.
Gasoline direct injection time bank a, 3 SANTA_CRUZ_GDI_IT_A3
- Request
22 E0 05 - Service 22
DID E005 - Module
7E0 → 7E8 - Every
1 s - Testing for 2021 to 2022, 2024, 2026
Bits 256 to 271 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 ms
- Unit
- ms
In testing for 2021 to 2022, 2024, 2026. Supported for 2023, 2025.
Gasoline direct injection time bank a, 4 SANTA_CRUZ_GDI_IT_A4
- Request
22 E0 05 - Service 22
DID E005 - Module
7E0 → 7E8 - Every
1 s - Testing for 2021 to 2022, 2024, 2026
Bits 272 to 287 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 ms
- Unit
- ms
In testing for 2021 to 2022, 2024, 2026. Supported for 2023, 2025.
Gasoline direct injection time bank b, 1 SANTA_CRUZ_GDI_IT_B1
- Request
22 E0 05 - Service 22
DID E005 - Module
7E0 → 7E8 - Every
1 s - Testing for 2021 to 2022, 2024, 2026
Bits 352 to 367 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 ms
- Unit
- ms
In testing for 2021 to 2022, 2024, 2026. Supported for 2023, 2025.
Gasoline direct injection time bank b, 2 SANTA_CRUZ_GDI_IT_B2
- Request
22 E0 05 - Service 22
DID E005 - Module
7E0 → 7E8 - Every
1 s - Testing for 2021 to 2022, 2024, 2026
Bits 368 to 383 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 ms
- Unit
- ms
In testing for 2021 to 2022, 2024, 2026. Supported for 2023, 2025.
Gasoline direct injection time bank b, 3 SANTA_CRUZ_GDI_IT_B3
- Request
22 E0 05 - Service 22
DID E005 - Module
7E0 → 7E8 - Every
1 s - Testing for 2021 to 2022, 2024, 2026
Bits 384 to 399 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 ms
- Unit
- ms
In testing for 2021 to 2022, 2024, 2026. Supported for 2023, 2025.
Gasoline direct injection time bank b, 4 SANTA_CRUZ_GDI_IT_B4
- Request
22 E0 05 - Service 22
DID E005 - Module
7E0 → 7E8 - Every
1 s - Testing for 2021 to 2022, 2024, 2026
Bits 400 to 415 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 ms
- Unit
- ms
In testing for 2021 to 2022, 2024, 2026. Supported for 2023, 2025.
Injection duration cylinder 1 SANTA_CRUZ_INJ_DUR_1Confirmed
- Request
22 E0 02 - Service 22
DID E002 - Module
7E0 → 7E8 - Every
5 s - Testing for 2021, 2026
Example reply from a 2025 Hyundai Santa Cruz.
Bits 176 to 191 of the reply, 16 bits. The bytes are in little-endian order.
0x0000 = 0 → (0 ÷ 1220.7) = 0 ms
- Formula
(val ÷ 1220.7)- Range
- 0 to 53 ms
- Unit
- ms
Confirmed for 2022 to 2025. In testing for 2021, 2026.
Injection duration cylinder 2 SANTA_CRUZ_INJ_DUR_2Confirmed
- Request
22 E0 02 - Service 22
DID E002 - Module
7E0 → 7E8 - Every
5 s - Testing for 2021, 2026
Example reply from a 2025 Hyundai Santa Cruz.
Bits 192 to 207 of the reply, 16 bits. The bytes are in little-endian order.
0x0000 = 0 → (0 ÷ 1220.7) = 0 ms
- Formula
(val ÷ 1220.7)- Range
- 0 to 53 ms
- Unit
- ms
Confirmed for 2022 to 2025. In testing for 2021, 2026.
Injection duration cylinder 3 SANTA_CRUZ_INJ_DUR_3Confirmed
- Request
22 E0 02 - Service 22
DID E002 - Module
7E0 → 7E8 - Every
5 s - Testing for 2021, 2026
Example reply from a 2025 Hyundai Santa Cruz.
Bits 208 to 223 of the reply, 16 bits. The bytes are in little-endian order.
0x0000 = 0 → (0 ÷ 1220.7) = 0 ms
- Formula
(val ÷ 1220.7)- Range
- 0 to 53 ms
- Unit
- ms
Confirmed for 2022 to 2025. In testing for 2021, 2026.
Injection duration cylinder 4 SANTA_CRUZ_INJ_DUR_4Confirmed
- Request
22 E0 02 - Service 22
DID E002 - Module
7E0 → 7E8 - Every
5 s - Testing for 2021, 2026
Example reply from a 2025 Hyundai Santa Cruz.
Bits 224 to 239 of the reply, 16 bits. The bytes are in little-endian order.
0x0000 = 0 → (0 ÷ 1220.7) = 0 ms
- Formula
(val ÷ 1220.7)- Range
- 0 to 53 ms
- Unit
- ms
Confirmed for 2022 to 2025. In testing for 2021, 2026.
Injection impulse 1, cylinder 1 SANTA_CRUZ_INJ_IMPULSE_1_CYL_1Confirmed
- Request
22 E0 23 - Service 22
DID E023 - Module
7E0 → 7E8 - Every
1 s - Testing for 2021 to 2022, 2024, 2026
Example reply from a 2025 Hyundai Santa Cruz.
Bits 200 to 215 of the reply, 16 bits. The bytes are in little-endian order.
0x0076 = 118 → (118 ÷ 250) = 0.472 ms
- Formula
(val ÷ 250)- Range
- 0 to 262.14 ms
- Unit
- ms
Confirmed for 2023, 2025. In testing for 2021 to 2022, 2024, 2026.
Injection impulse 1, cylinder 2 SANTA_CRUZ_INJ_IMPULSE_1_CYL_2Confirmed
- Request
22 E0 23 - Service 22
DID E023 - Module
7E0 → 7E8 - Every
1 s - Testing for 2021 to 2022, 2024, 2026
Example reply from a 2025 Hyundai Santa Cruz.
Bits 216 to 231 of the reply, 16 bits. The bytes are in little-endian order.
0x0076 = 118 → (118 ÷ 250) = 0.472 ms
- Formula
(val ÷ 250)- Range
- 0 to 262.14 ms
- Unit
- ms
Confirmed for 2023, 2025. In testing for 2021 to 2022, 2024, 2026.
Injection impulse 1, cylinder 3 SANTA_CRUZ_INJ_IMPULSE_1_CYL_3Confirmed
- Request
22 E0 23 - Service 22
DID E023 - Module
7E0 → 7E8 - Every
1 s - Testing for 2021 to 2022, 2024, 2026
Example reply from a 2025 Hyundai Santa Cruz.
Bits 232 to 247 of the reply, 16 bits. The bytes are in little-endian order.
0x0070 = 112 → (112 ÷ 250) = 0.448 ms
- Formula
(val ÷ 250)- Range
- 0 to 262.14 ms
- Unit
- ms
Confirmed for 2023, 2025. In testing for 2021 to 2022, 2024, 2026.
Injection impulse 1, cylinder 4 SANTA_CRUZ_INJ_IMPULSE_1_CYL_4Confirmed
- Request
22 E0 23 - Service 22
DID E023 - Module
7E0 → 7E8 - Every
1 s - Testing for 2021 to 2022, 2024, 2026
Example reply from a 2025 Hyundai Santa Cruz.
Bits 248 to 263 of the reply, 16 bits. The bytes are in little-endian order.
0x0076 = 118 → (118 ÷ 250) = 0.472 ms
- Formula
(val ÷ 250)- Range
- 0 to 262.14 ms
- Unit
- ms
Confirmed for 2023, 2025. In testing for 2021 to 2022, 2024, 2026.
Injection impulse 2, cylinder 1 SANTA_CRUZ_INJ_IMPULSE_2_CYL_1Confirmed
- Request
22 E0 23 - Service 22
DID E023 - Module
7E0 → 7E8 - Every
1 s - Testing for 2021 to 2022, 2024, 2026
Example reply from a 2025 Hyundai Santa Cruz.
Bits 264 to 279 of the reply, 16 bits. The bytes are in little-endian order.
0x0000 = 0 → (0 ÷ 250) = 0 ms
- Formula
(val ÷ 250)- Range
- 0 to 262.14 ms
- Unit
- ms
Confirmed for 2023, 2025. In testing for 2021 to 2022, 2024, 2026.
Injection impulse 2, cylinder 2 SANTA_CRUZ_INJ_IMPULSE_2_CYL_2Confirmed
- Request
22 E0 23 - Service 22
DID E023 - Module
7E0 → 7E8 - Every
1 s - Testing for 2021 to 2022, 2024, 2026
Example reply from a 2025 Hyundai Santa Cruz.
Bits 280 to 295 of the reply, 16 bits. The bytes are in little-endian order.
0x0000 = 0 → (0 ÷ 250) = 0 ms
- Formula
(val ÷ 250)- Range
- 0 to 262.14 ms
- Unit
- ms
Confirmed for 2023, 2025. In testing for 2021 to 2022, 2024, 2026.
Injection impulse 2, cylinder 3 SANTA_CRUZ_INJ_IMPULSE_2_CYL_3Confirmed
- Request
22 E0 23 - Service 22
DID E023 - Module
7E0 → 7E8 - Every
1 s - Testing for 2021 to 2022, 2024, 2026
Example reply from a 2025 Hyundai Santa Cruz.
Bits 296 to 311 of the reply, 16 bits. The bytes are in little-endian order.
0x0000 = 0 → (0 ÷ 250) = 0 ms
- Formula
(val ÷ 250)- Range
- 0 to 262.14 ms
- Unit
- ms
Confirmed for 2023, 2025. In testing for 2021 to 2022, 2024, 2026.
Injection impulse 2, cylinder 4 SANTA_CRUZ_INJ_IMPULSE_2_CYL_4Confirmed
- Request
22 E0 23 - Service 22
DID E023 - Module
7E0 → 7E8 - Every
1 s - Testing for 2021 to 2022, 2024, 2026
Example reply from a 2025 Hyundai Santa Cruz.
Bits 312 to 327 of the reply, 16 bits. The bytes are in little-endian order.
0x0000 = 0 → (0 ÷ 250) = 0 ms
- Formula
(val ÷ 250)- Range
- 0 to 262.14 ms
- Unit
- ms
Confirmed for 2023, 2025. In testing for 2021 to 2022, 2024, 2026.
Injection impulse 3, cylinder 1 SANTA_CRUZ_INJ_IMPULSE_3_CYL_1Confirmed
- Request
22 E0 23 - Service 22
DID E023 - Module
7E0 → 7E8 - Every
1 s - Testing for 2021 to 2022, 2024, 2026
Example reply from a 2025 Hyundai Santa Cruz.
Bits 328 to 343 of the reply, 16 bits. The bytes are in little-endian order.
0x0000 = 0 → (0 ÷ 25) = 0 ms
- Formula
(val ÷ 25)- Range
- 0 to 2621.4 ms
- Unit
- ms
Confirmed for 2023, 2025. In testing for 2021 to 2022, 2024, 2026.
Injection impulse 3, cylinder 2 SANTA_CRUZ_INJ_IMPULSE_3_CYL_2Confirmed
- Request
22 E0 23 - Service 22
DID E023 - Module
7E0 → 7E8 - Every
1 s - Testing for 2021 to 2022, 2024, 2026
Example reply from a 2025 Hyundai Santa Cruz.
Bits 344 to 359 of the reply, 16 bits. The bytes are in little-endian order.
0x0000 = 0 → (0 ÷ 25) = 0 ms
- Formula
(val ÷ 25)- Range
- 0 to 2621.4 ms
- Unit
- ms
Confirmed for 2023, 2025. In testing for 2021 to 2022, 2024, 2026.
Injection impulse 3, cylinder 3 SANTA_CRUZ_INJ_IMPULSE_3_CYL_3Confirmed
- Request
22 E0 23 - Service 22
DID E023 - Module
7E0 → 7E8 - Every
1 s - Testing for 2021 to 2022, 2024, 2026
Example reply from a 2025 Hyundai Santa Cruz.
Bits 360 to 375 of the reply, 16 bits. The bytes are in little-endian order.
0x0000 = 0 → (0 ÷ 25) = 0 ms
- Formula
(val ÷ 25)- Range
- 0 to 2621.4 ms
- Unit
- ms
Confirmed for 2023, 2025. In testing for 2021 to 2022, 2024, 2026.
Injection impulse 3, cylinder 4 SANTA_CRUZ_INJ_IMPULSE_3_CYL_4Confirmed
- Request
22 E0 23 - Service 22
DID E023 - Module
7E0 → 7E8 - Every
1 s - Testing for 2021 to 2022, 2024, 2026
Example reply from a 2025 Hyundai Santa Cruz.
Bits 376 to 391 of the reply, 16 bits. The bytes are in little-endian order.
0x0000 = 0 → (0 ÷ 25) = 0 ms
- Formula
(val ÷ 25)- Range
- 0 to 2621.4 ms
- Unit
- ms
Confirmed for 2023, 2025. In testing for 2021 to 2022, 2024, 2026.
Injector correction factor 1 SANTA_CRUZ_INJ_CORR_FACTOR_1
- Request
22 E0 07 - Service 22
DID E007 - Module
7E0 → 7E8 - Every
30 s - Testing
Bits 208 to 223 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val × 2 ÷ 65535)- Range
- 0 to 2
- Unit
- Number
In testing for 2021 to 2024, 2026. Not supported for 2025.
Injector correction factor 2 SANTA_CRUZ_INJ_CORR_FACTOR_2
- Request
22 E0 07 - Service 22
DID E007 - Module
7E0 → 7E8 - Every
30 s - Testing
Bits 224 to 239 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val × 2 ÷ 65535)- Range
- 0 to 2
- Unit
- Number
In testing for 2021 to 2024, 2026. Not supported for 2025.
Injector correction factor 3 SANTA_CRUZ_INJ_CORR_FACTOR_3
- Request
22 E0 07 - Service 22
DID E007 - Module
7E0 → 7E8 - Every
30 s - Testing
Bits 240 to 255 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val × 2 ÷ 65535)- Range
- 0 to 2
- Unit
- Number
In testing for 2021 to 2024, 2026. Not supported for 2025.
Injector correction factor 4 SANTA_CRUZ_INJ_CORR_FACTOR_4
- Request
22 E0 07 - Service 22
DID E007 - Module
7E0 → 7E8 - Every
30 s - Testing
Bits 256 to 271 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val × 2 ÷ 65535)- Range
- 0 to 2
- Unit
- Number
In testing for 2021 to 2024, 2026. Not supported for 2025.
Intake air temperature IATSAE J1979Confirmed
- Request
01 0F - Service 01
PID 0F - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2023. Supported for 2022, 2025.
Intake air temperature SANTA_CRUZ_EITConfirmed
- Request
22 E0 01 - Service 22
DID E001 - Module
7E0 → 7E8 - Every
5 s - Testing for 2021, 2026
Example reply from a 2025 Hyundai Santa Cruz.
Bits 264 to 271 of the reply, 8 bits.
0x8C = 140 → (140 × 3 ÷ 4 − 48) = 57 °C
- Formula
(val × 3 ÷ 4 − 48)- Range
- -48 to 143 °C
- Unit
- °C
Confirmed for 2022 to 2025. In testing for 2021, 2026.
Intake camshaft position SANTA_CRUZ_INT_CAM_POSConfirmed
- Request
22 E0 20 - Service 22
DID E020 - Module
7E0 → 7E8 - Every
1 s - Testing for 2021 to 2022, 2024, 2026
Example reply from a 2025 Hyundai Santa Cruz.
Bits 72 to 87 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
0x3F00 = 16128 → (16128 ÷ 128) = 126 °
- Formula
(val ÷ 128)- Range
- -256 to 255 °
- Unit
- °
Confirmed for 2023, 2025. In testing for 2021 to 2022, 2024, 2026.
Intake manifold absolute pressure MAPSAE J1979Confirmed
- Request
01 0B - Service 01
PID 0B - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 kPa
- Unit
- kPa
Confirmed for 2023. Supported for 2022, 2024 to 2025.
Knock detected SANTA_CRUZ_KNOCK_DETECTED_7E0Confirmed
- Request
22 E0 04 - Service 22
DID E004 - Module
7E0 → 7E8 - Every
1 s - Testing for 2021, 2026
Example reply from a 2025 Hyundai Santa Cruz.
Bits 168 to 175 of the reply, 8 bits.
0x10 = 16 → 16
- Formula
val- Range
- 0 to 255
- Unit
- Number
Confirmed for 2022 to 2025. In testing for 2021, 2026.
Long term fuel trim (bank 1) LONGFT1SAE J1979Confirmed
- Request
01 07 - Service 01
PID 07 - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 128 − 100)- Range
- -100 to 99.2 %
- Unit
- %
Confirmed for 2023. Supported for 2022, 2024 to 2025.
Long term secondary O2 sensor fuel trim (bank 1) LGSO2FT1SAE J1979Confirmed
- Request
01 56 - Service 01
PID 56 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 128 − 100)- Range
- -100 to 99.22 %
- Unit
- %
Confirmed for 2023.
Mass air flow rate SANTA_CRUZ_MAF_RATEConfirmed
- Request
22 E0 10 - Service 22
DID E010 - Module
7E0 → 7E8 - Every
1 s - Testing for 2021 to 2022, 2024, 2026
Example reply from a 2025 Hyundai Santa Cruz.
Bits 208 to 215 of the reply, 8 bits. The bytes are in little-endian order.
0xBF = 191 → (191 × 0.04239) = 8.09649
- Formula
(val × 0.04239)- Range
- 0 to 10.8
- Unit
- Raw value
Confirmed for 2023, 2025. In testing for 2021 to 2022, 2024, 2026.
Misfires harmful for catalyst, cylinder 1 SANTA_CRUZ_MIS_HARMFUL_CAT_1Confirmed
- Request
22 E0 1D - Service 22
DID E01D - Module
7E0 → 7E8 - Every
1 s - Testing for 2021 to 2022, 2024, 2026
Example reply from a 2025 Hyundai Santa Cruz.
Bits 160 to 175 of the reply, 16 bits. The bytes are in little-endian order.
0x0000 = 0 → 0
- Formula
val- Range
- 0 to 65535
- Unit
- Number
Confirmed for 2023, 2025. In testing for 2021 to 2022, 2024, 2026.
Misfires harmful for catalyst, cylinder 2 SANTA_CRUZ_MIS_HARMFUL_CAT_2Confirmed
- Request
22 E0 1D - Service 22
DID E01D - Module
7E0 → 7E8 - Every
1 s - Testing for 2021 to 2022, 2024, 2026
Example reply from a 2025 Hyundai Santa Cruz.
Bits 176 to 191 of the reply, 16 bits. The bytes are in little-endian order.
0x0000 = 0 → 0
- Formula
val- Range
- 0 to 65535
- Unit
- Number
Confirmed for 2023, 2025. In testing for 2021 to 2022, 2024, 2026.
Misfires harmful for catalyst, cylinder 3 SANTA_CRUZ_MIS_HARMFUL_CAT_3Confirmed
- Request
22 E0 1D - Service 22
DID E01D - Module
7E0 → 7E8 - Every
1 s - Testing for 2021 to 2022, 2024, 2026
Example reply from a 2025 Hyundai Santa Cruz.
Bits 192 to 207 of the reply, 16 bits. The bytes are in little-endian order.
0x0000 = 0 → 0
- Formula
val- Range
- 0 to 65535
- Unit
- Number
Confirmed for 2023, 2025. In testing for 2021 to 2022, 2024, 2026.
Misfires harmful for catalyst, cylinder 4 SANTA_CRUZ_MIS_HARMFUL_CAT_4Confirmed
- Request
22 E0 1D - Service 22
DID E01D - Module
7E0 → 7E8 - Every
1 s - Testing for 2021 to 2022, 2024, 2026
Example reply from a 2025 Hyundai Santa Cruz.
Bits 208 to 223 of the reply, 16 bits. The bytes are in little-endian order.
0x0000 = 0 → 0
- Formula
val- Range
- 0 to 65535
- Unit
- Number
Confirmed for 2023, 2025. In testing for 2021 to 2022, 2024, 2026.
Misfires, cylinder 1 SANTA_CRUZ_MIS_1_7E0Confirmed
- Request
22 E0 1D - Service 22
DID E01D - Module
7E0 → 7E8 - Every
1 s - Testing for 2021 to 2022, 2024, 2026
Example reply from a 2025 Hyundai Santa Cruz.
Bits 32 to 47 of the reply, 16 bits. The bytes are in little-endian order.
0x0000 = 0 → 0
- Formula
val- Range
- 0 to 65535
- Unit
- Number
Confirmed for 2023, 2025. In testing for 2021 to 2022, 2024, 2026.
Misfires, cylinder 2 SANTA_CRUZ_MIS_2_7E0Confirmed
- Request
22 E0 1D - Service 22
DID E01D - Module
7E0 → 7E8 - Every
1 s - Testing for 2021 to 2022, 2024, 2026
Example reply from a 2025 Hyundai Santa Cruz.
Bits 48 to 63 of the reply, 16 bits. The bytes are in little-endian order.
0x0000 = 0 → 0
- Formula
val- Range
- 0 to 65535
- Unit
- Number
Confirmed for 2023, 2025. In testing for 2021 to 2022, 2024, 2026.
Misfires, cylinder 3 SANTA_CRUZ_MIS_3_7E0Confirmed
- Request
22 E0 1D - Service 22
DID E01D - Module
7E0 → 7E8 - Every
1 s - Testing for 2021 to 2022, 2024, 2026
Example reply from a 2025 Hyundai Santa Cruz.
Bits 64 to 79 of the reply, 16 bits. The bytes are in little-endian order.
0x0000 = 0 → 0
- Formula
val- Range
- 0 to 65535
- Unit
- Number
Confirmed for 2023, 2025. In testing for 2021 to 2022, 2024, 2026.
Misfires, cylinder 4 SANTA_CRUZ_MIS_4_7E0Confirmed
- Request
22 E0 1D - Service 22
DID E01D - Module
7E0 → 7E8 - Every
1 s - Testing for 2021 to 2022, 2024, 2026
Example reply from a 2025 Hyundai Santa Cruz.
Bits 80 to 95 of the reply, 16 bits. The bytes are in little-endian order.
0x0000 = 0 → 0
- Formula
val- Range
- 0 to 65535
- Unit
- Number
Confirmed for 2023, 2025. In testing for 2021 to 2022, 2024, 2026.
Motor-driven power steering current SANTA_CRUZ_MDPS_MOTOR_CURRENTConfirmed
- Request
22 01 01 - Service 22
DID 0101 - Module
7D4 → 7DC - Every
5 s - Testing for 2021, 2026
Example reply from a 2025 Hyundai Santa Cruz.
Bits 88 to 95 of the reply, 8 bits. The value is signed.
0x00 = 0 → 0 A
- Formula
val- Range
- -128 to 127 A
- Unit
- A
Confirmed for 2022 to 2025. In testing for 2021, 2026.
Overheat protection, active SANTA_CRUZ_OVERHEAT_PROTECTIONConfirmed
- Request
22 E0 14 - Service 22
DID E014 - Module
7E0 → 7E8 - Every
1 s - Testing for 2021 to 2022, 2024, 2026
Example reply from a 2025 Hyundai Santa Cruz.
Bit 132 of the reply.
0b0 = 0 → 0
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
Confirmed for 2023, 2025. In testing for 2021 to 2022, 2024, 2026.
Parking sensor rear center left level SANTA_CRUZ_PARKING_SENS_REARConfirmed
- Request
22 B0 09 - Service 22
DID B009 - Module
7A0 → 7A8 - Every
1 s - Testing for 2021 to 2024, 2026
Example reply from a 2025 Hyundai Santa Cruz.
Bits 32 to 39 of the reply, 8 bits.
0x00 = 0 → 0
- Formula
val- Range
- 0 to 255
- Unit
- Number
Confirmed for 2025. In testing for 2021 to 2024, 2026.
Parking sensor rear center right level SANTA_CRUZ_PARKING_SENS_REAR_CENTERConfirmed
- Request
22 B0 09 - Service 22
DID B009 - Module
7A0 → 7A8 - Every
1 s - Testing for 2021 to 2024, 2026
Example reply from a 2025 Hyundai Santa Cruz.
Bits 40 to 47 of the reply, 8 bits.
0x00 = 0 → 0
- Formula
val- Range
- 0 to 255
- Unit
- Number
Confirmed for 2025. In testing for 2021 to 2024, 2026.
Short term fuel trim (bank 1) SHRTFT1SAE J1979Confirmed
Correction being used by the closed-loop fuel algorithm.
Pelican can show this parameter as the short term fuel trim.
- Request
01 06 - Service 01
PID 06 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 128 − 100)- Range
- -100 to 99.2 %
- Unit
- %
Confirmed for 2022 to 2023, 2025. Supported for 2024.
Short term secondary O2 sensor fuel trim (bank 1) STSO2FT1SAE J1979Confirmed
- Request
01 55 - Service 01
PID 55 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 128 − 100)- Range
- -100 to 99.22 %
- Unit
- %
Confirmed for 2023.
Timing advance SPARKADVSAE J1979Confirmed
Ignition timing spark advance for the first cylinder. Measured in degrees before dead center. Minus is degrees before dead center, positive is degrees after.
- Request
01 0E - Service 01
PID 0E - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 2 − 64)- Range
- -64 to 63.5 °
- Unit
- °
Confirmed for 2023. Supported for 2022, 2024 to 2025.
Torque converter slip SANTA_CRUZ_TORQUE_CONVERTER_SLIP_7E1Confirmed
- Request
22 01 A0 - Service 22
DID 01A0 - Module
7E1 → 7E9 - Every
250 ms - Testing for 2021 to 2024, 2026
Example reply from a 2025 Hyundai Santa Cruz.
Bits 128 to 143 of the reply, 16 bits.
0x0800 = 2048 → (2048 ÷ 4 − 512) = 0 rpm
- Formula
(val ÷ 4 − 512)- Range
- -512 to 15871.75 rpm
- Unit
- rpm
Confirmed for 2025. In testing for 2021, 2024, 2026. Not supported for 2022 to 2023.
Turbo boost pressure SANTA_CRUZ_TB_PRESConfirmed
- Request
22 E0 21 - Service 22
DID E021 - Module
7E0 → 7E8 - Every
1 s - Testing for 2021, 2026
Example reply from a 2025 Hyundai Santa Cruz.
Bits 56 to 71 of the reply, 16 bits.
0x0000 = 0 → (0 × 0.008291) = 0 kPa
- Formula
(val × 0.008291)- Range
- 0 to 543 kPa
- Unit
- kPa
Confirmed for 2022 to 2025. In testing for 2021, 2026.
Type of fuel currently being used by the vehicle FUEL_TYPSAE J1979Confirmed
- Request
01 51 - Service 01
PID 51 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
1 | GAS | Gasoline/petrol |
2 | METH | Methanol |
3 | ETH | Ethanol |
4 | DSL | Diesel |
5 | LPG | Liquefied petroleum gas |
6 | CNG | Compressed natural gas |
7 | PROP | Propane |
8 | ELEC | Battery/electric |
9 | BI_GAS | Bi-fuel vehicle using gasoline/petrol |
10 | BI_METH | Bi-fuel vehicle using methanol |
11 | BI_ETH | Bi-fuel vehicle using ethanol |
12 | BI_LPG | Bi-fuel vehicle using LPG |
13 | BI_CNG | Bi-fuel vehicle using CNG |
14 | BI_PROP | Bi-fuel vehicle using propane |
15 | BI_ELEC | Bi-fuel vehicle using battery |
16 | BI_MIX | Bi-fuel vehicle using battery and combustion engine for propulsion |
17 | HYB_GAS | Hybrid vehicle using gasoline engine for propulsion |
18 | HYB_ETH | Hybrid vehicle using gasoline engine on ethanol for propulsion |
19 | HYB_DSL | Hybrid vehicle using diesel engine for propulsion |
20 | HYB_ELEC | Hybrid vehicle using battery for propulsion |
21 | HYB_MIX | Hybrid vehicle using battery and combustion engine for propulsion |
22 | HYB_REG | Hybrid vehicle in regeneration mode |
23 | BI_DSL | Bi-fuel vehicle using diesel |
24 | BI_NG | Bi-fuel vehicle using natural gas |
25 | BI_DSL | Bi-fuel vehicle using diesel |
26 | NG | Natural gas |
27 | DSL_CNG | Dual fuel vehicle using diesel and CNG |
28 | DSL_LNG | Dual fuel vehicle using diesel and LNG |
29 | FC_H2 | Fuel cell utilizing hydrogen |
30 | HICE_HHO | Hydrogen Internal Combustion Engine |
31 | KERO | Kerosene |
32 | HFO | Heavy Fuel Oil |
Confirmed for 2023.
Waste gate duty SANTA_CRUZ_WG_DUTYConfirmed
- Request
22 E0 21 - Service 22
DID E021 - Module
7E0 → 7E8 - Every
1 s - Testing for 2021, 2026
Example reply from a 2025 Hyundai Santa Cruz.
Bits 408 to 423 of the reply, 16 bits.
0x0000 = 0 → (0 × 0.00305176) = 0 %
- Formula
(val × 0.00305176)- Range
- 0 to 199 %
- Unit
- %
Confirmed for 2022 to 2025. In testing for 2021, 2026.
Waste gate voltage SANTA_CRUZ_WG_VConfirmed
- Request
22 E0 21 - Service 22
DID E021 - Module
7E0 → 7E8 - Every
1 s - Testing for 2021, 2026
Example reply from a 2025 Hyundai Santa Cruz.
Bits 392 to 407 of the reply, 16 bits.
0x0000 = 0 → (0 × 0.000152588) = 0 V
- Formula
(val × 0.000152588)- Range
- 0 to 9.99 V
- Unit
- V
Confirmed for 2022 to 2025. In testing for 2021, 2026.
Wide open throttle SANTA_CRUZ_WIDE_OPEN_THROTTLEConfirmed
- Request
22 E0 04 - Service 22
DID E004 - Module
7E0 → 7E8 - Every
1 s - Testing for 2021, 2026
Example reply from a 2025 Hyundai Santa Cruz.
Bits 72 to 79 of the reply, 8 bits.
0x72 = 114 → 114
- Formula
val- Range
- 0 to 255
- Unit
- Number
Confirmed for 2022 to 2025. In testing for 2021, 2026.
Engine › Internal
Is ECT sensor 1 supported? ECT_1_SUPSAE J1979Confirmed
- Request
01 67 - Service 01
PID 67 - Module
7E0 → 7E8 - Every
1 s
Bit 7 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
Confirmed for 2023.
Is ECT sensor 2 supported? ECT_2_SUPSAE J1979Confirmed
- Request
01 67 - Service 01
PID 67 - Module
7E0 → 7E8 - Every
1 s
Bit 6 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
Confirmed for 2023.
Engine › OxygenSensors
02S Bank 1, Sensor 1 present O2S11_EXISTSSAE J1979Confirmed
- Request
01 13 - Service 01
PID 13 - Module
7E0 → 7E8 - Every
3600 s
Bit 7 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2023. Supported for 2022, 2024 to 2025.
02S Bank 1, Sensor 2 present O2S12_EXISTSSAE J1979Confirmed
- Request
01 13 - Service 01
PID 13 - Module
7E0 → 7E8 - Every
3600 s
Bit 6 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2023. Supported for 2022, 2024 to 2025.
02S Bank 1, Sensor 3 present O2S13_EXISTSSAE J1979Confirmed
- Request
01 13 - Service 01
PID 13 - Module
7E0 → 7E8 - Every
3600 s
Bit 5 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2023. Supported for 2022, 2024 to 2025.
02S Bank 1, Sensor 4 present O2S14_EXISTSSAE J1979Confirmed
- Request
01 13 - Service 01
PID 13 - Module
7E0 → 7E8 - Every
3600 s
Bit 4 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2023. Supported for 2022, 2024 to 2025.
02S Bank 2, Sensor 1 present O2S21_EXISTSSAE J1979Confirmed
- Request
01 13 - Service 01
PID 13 - Module
7E0 → 7E8 - Every
3600 s
Bit 3 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2023. Supported for 2022, 2024 to 2025.
02S Bank 2, Sensor 2 present O2S22_EXISTSSAE J1979Confirmed
- Request
01 13 - Service 01
PID 13 - Module
7E0 → 7E8 - Every
3600 s
Bit 2 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2023. Supported for 2022, 2024 to 2025.
02S Bank 2, Sensor 3 present O2S23_EXISTSSAE J1979Confirmed
- Request
01 13 - Service 01
PID 13 - Module
7E0 → 7E8 - Every
3600 s
Bit 1 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2023. Supported for 2022, 2024 to 2025.
02S Bank 2, Sensor 4 present O2S24_EXISTSSAE J1979Confirmed
- Request
01 13 - Service 01
PID 13 - Module
7E0 → 7E8 - Every
3600 s
Bit 0 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2023. Supported for 2022, 2024 to 2025.
Lambda value, Equivalence Ratio Bank 1, Sensor 1 LAMBDA11_CURRENTSAE J1979Confirmed
Pelican can show this parameter as the O2 lambda.
- Request
01 34 - Service 01
PID 34 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 32768)- Range
- 0 to 1.99
- Unit
- Number
Confirmed for 2022 to 2023, 2025. Supported for 2024.
O2S Output Voltage Bank 1, Sensor 2 O2S12SAE J1979Confirmed
- Request
01 15 - Service 01
PID 15 - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 200)- Range
- 0 to 1.275 V
- Unit
- V
Confirmed for 2023. Supported for 2022, 2024 to 2025.
SHRTFT associated with O2S11 SHRTFT11SAE J1979Confirmed
- Request
01 14 - Service 01
PID 14 - Module
7E0 → 7E8 - Every
1 s
Bits 8 to 15 of the reply, 8 bits.
- Formula
(val × 100 ÷ 128 − 128)- Range
- -100 to 99.22 %
- Unit
- %
Confirmed for 2023. Supported for 2022, 2024 to 2025.
Wide Range O2S Current, O2 Sensor Bank 1, Sensor 1 O2S11_CURRENTSAE J1979Confirmed
- Request
01 34 - Service 01
PID 34 - Module
7E0 → 7E8 - Every
250 ms
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val ÷ 256 − 128)- Range
- -128 to 127.996 mA
- Unit
- mA
Confirmed for 2022 to 2023, 2025. Supported for 2024.